Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹98.2 LAccepted-AOC | L1 | Accepted-AOC work allotted | |
| 2 | L2₹1.1 Cr+₹5.5 L (5.49%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹1.1 Cr+₹13.0 L (13.0%)Rejected-Finance AMAR NIWAS RA 288 GANDHI CHOWK SADAR BAZAR KARNAL | KARNAL | KARNAL | HARYANA | L3 | Rejected-Finance L3 |
Tender Value
₹85.1 L
EMD Value
₹1.7 L
Closing Date
10 Sept 2021, 2:00 pmClosed
Executive Engineer
Executive Engineer, Elect. Division PWD BandR Br., Karnal (0184-2265696)
Construction of the building Mother and Child Block at Civil Hospital at Panipat (Pdg. EI only) Recall
2021_HRY_182620_2
MCH Panipat EI only
Open Tender
Electrical Works
Works
300 days
Panipat
Please refer Tender documents.
3 documents required · 3 mandatory
₹5,000
₹1.7 L
13 Apr 2022
20 Aug 2021
10 Sept 2021
20 Aug 2021
10 Sept 2021
20 Aug 2021
Amount
COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (RECESS) 23.4.1.3 Wiring for Light/Fan/call bell point with modular type switch/socket and GI box, Modular type face plate etc in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe. Group C
23.4.2.3 Wiring for Twin control light point with 2 nos , 2-ways, 5 amp. Modular switch GI box and modular face plate in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe. Group C
23.4.3.3 Wiring for Light/Fan/call bell point in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe, without separate control switch Group C
23.4.4.3 Wiring in PVC conduit system for 3-pin 5amp. Plug point by using 2 no 1.5 sqmm FRLS copper wire and 1 no 1.5 Sqmm FRLS copper wire , including providing 1 no 5/6 Amp 3/5 pin Modular type socket and 1 no 5/6 Amp Modular type switch required GI Box ,modular face plate etc complete as required Group C
23.4.5.3 Wiring in PVC conduit system for 3-pin 15amp. Plug point by using 2 no 4 sqmm FRLS copper wire and 1 no 4 Sqmm FRLS copper wire for earthling , including providing 1 no 15/16 Amp 3/6 pin Modular socket and 1 no 15/16 Amp Modular switch required GI Box , modular face plate etc complete as required Group C
23.3.6.2 Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 1 run of Size 2.50 Sqmm(1.1.80mm)
23.3.6.7 2 run of Size 2.50 Sqmm(1.1.80mm)
23.3.6.10 3 run of Size 2.50 Sqmm(1.1.80mm)
23.5.6.2 Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 2.50 Sqmm(1.1.80mm)
23.5.6.7 2 run of Size 2.50 Sqmm(1.1.80mm)
23.5.6.10 3 run of Size 2.50 Sqmm(1.1.80mm)
23.6.6.1 Supply and erection of MS conduit pipe 1.6 mm thick , ISI marked surface/recessed in slab/wall/ceiling etc. including cost of MS bends, inspection box and all other material required to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work. MS Pipe of 20 mm dia.
23.6.6.2 MS pipe of 25 mm dia.
23.7.6.1 PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 20 mm dia.
23.7.6.2 PVC pipe of 25 mm dia.
23.7.6.3 PVC pipe of 32 mm dia.
23.7.6.4 PVC pipe of 40 mm dia.
23.8.1.5 Providing and fixing Piano type accessories of approved make in existing box and Bakelite sheet including fixing and making necessary connections, complete in all respect. Ceiling rose flush/surface type
23.8.1.6 Call bell 220/230 volts musical type
23.8.1.7 Electric buzzer 220/230 volts A.C. Bakelite with double coil.
23.8.1.8 Bell push with 4 metres 2-core, 0.50 sqmm (16/0.20 mm) PVC flexible wire.
23.8.1.12 Bakelite angle/straight button holder large size.
23.8.4 Supply and erection of 10.5 cm dia M.S.Fan box including 8 mm dia 30 cm long M.S. Road made into suitable suspension hook and erected in R.C.C. slab for the erection of fan complete with all labour and material required to complete the job.
23.8.10.3 Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. 1 & 2 Modules including combined plate for Telephone and data 4 Modules
23.8.11.1 Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 5 amp 1 way switch
23.8.11.4 5 amp Socket
23.8.11.7 step type Fan Regulator 2 modules 300 watt
23.8.11.8 Telephone Socket outlet modular type
23.8.11.9 T.V. Socket outlet modular type
23.8.11.10 Blanking plate
23.8.11.11 RJ 45 Computer DATA socket outlet for CAT 6 or CAT6e cable Modular type
23.8.11.12 USB Charger, 1000mA, 5V, 1 Module
23.8.13 Supplying,installation,testing and commissioning of Passive Infrared(PIR) based occupancy sensor , non regulating programmable type, suitable for connected load upto 10Amp , for mounting height up to 2.8 mtr and for 5 m diameter coverage area along with necessary fixing arrangements i/c programming at site etc. complete as required.
23.9 Erection of exhaust fan in existing opening ,complete with necessary earthling of fan including carriage from PWD store to the site of work.
23.10 Erection of cabin fan complete with necessary earthling including carriage from PWD store to the site of work.
23.11 Making suitable hole in the wall suitable for exhaust fan up to 450 mm sweep including finishing the same and fixing of Stainless stell wire mesh 2 mm thick having about 50 meshes per inch at exhaust side complete as required
23.12 Providing and fixing outdoor duty Ply of 8 mm thick frame suitable for exhaust fan up to 450 mm sweep etc complete as required
23.20 Fixing of LED Tube light/ 2*2 ft square panel fitting directly on wall /ceiling or false ceiling including making connections etc as required.
23.21 Fixing of LED Down lighter 7 to 28 Watt on ceiling or in false ceiling , including cutting/making hole in ceiling including making connections etc as required
23.22.1.3 Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. TRIPLE POLE MCCB 16 to 100 Amp, 25 KA
23.22.1.5 TRIPLE POLE MCCB 200 to 250 Amp, 25 KA
23.22.1.7 TRIPLE POLE MCCB 400 Amp, 50 KA
23.22.1.9 4 pole MCCB 16 amp to 100 amp, 25 KA
23.22.1.11 4 pole MCCB 200 to 250 amp, 25 KA
23.22.1.12 4 pole MCCB 300 to 400 amp, 50 KA
23.22.3.2 Supply and erection of sheet steel enclosures 1pole/ 2 pole/4 pole including providing SP/DP/TP/FP MCB on wall/on existing pedestal complete with necessary connections etc, :- SPN or DP enclosure Suitable for DPMCB
23.22.3.3 TPN enclosure suitable for TP,TPN or FPMCB
23.22.4.1 Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to to the entire satisfaction of the Engineer-in-Charge of the work. SPN DB Double Door 4 way ( 2 incoming and 2 outgoing)
23.22.4.3 SPN DB Double Door 12 way ( 2 incoming and 10 outgoing)
23.22.4.5 TPN DB Horizontal type Double Door 4 way ( 8 incoming and 3phase*4 outgoing)
23.22.4.6 TPN DB Horizontal type Double Door 6 way ( 8 incoming 3phase*6 outgoing)
23.22.5.1 Supply and erection of miniature circuit Breaker/isolator 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Single Pole
23.22.5.5 6 amp. to 32 amp MCB's TRIPLE POLE
23.22.6.1 Supply and erection double pole/Four pole Residual (RCCB/ELCB) on 240/415V, 5Hz. AC supply installed in existing sheet steel enclosures including making necessary connections and bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. DP RCCB 30mA sensitivity , 25 A
23.22.6.2 DP RCCB 30mA sensitivity , 40 A
23.22.7 Supply and erection of blanking sheet in existing distribution board.
23.22.8.3 SITC Four pole ON LOAD Manual change over switch in SS enclosure of following Ratings 200 amp 415 volts
23.23.1.2 Supply and fixing Galvanised Iron flexible pipe complete with socket nipples and check nuts etc. at both ends (Up to length of one metre):- Size 20 mm dia
23.23.1.3 Size 25 mm dia
23.23.2.1 Supply of GI pipe (B-Class) for suspension rod of ceiling fan including threading if required. 15 mm dia
23.23.2.2 20 mm dia
23.23.5.4 Supply and erection of U- PVC Trunking/Channel of following size including cost of fixing on wall, floor and ceiling etc. with required material complete the job in all respect up to entire satisfaction of the Engineer-in-charge of work. 50x50 mm
23.23.6.2 Supply and erection of MS cable tray , duly pained as required including erection of the same on wall or ceiling with necessary fixture and other material required to complete the job in all respect up to the entire satisfaction of Engineer-in Charge of the work. MS perforated cable tray painted with powder coating 200 X 50 X 1.6 mm3
23.23.7.2 Supply and erection of cable tray cover made of 1.25 mm thick GI sheet as required including erection of the same on existing cable tray with necessary fixture and other material required to complete the job in all respect up to the entire satisfaction of Engineer-in charge of the work. GI cable tray cover suitable for cable tray of 200*50*2 mm
23.24.4.4 Load Bank 8 way 400 A
23.26.1 Supply and erection of Medium Voltage caution notice plate of size 200*150 mm in three languages.
23.26.3 Supply and erection of shock restoration chart in glass frame.
23.26.4 Supply & Erection of mild steel bucket stand suitable for 6 Nos. fire buckets,(but without bucket) including the cost of welding and painting of complete stand will one coat of red oxide and 2 coats of approved paint of red colour with all labour and material required to complete the job in all respect up to the entire Satisfaction engineer in charge of the work (size 6'x4' made of GI pipe 32mm dia).
24.1.3 Earthing with G.I. earth plate 600 mmx 600 mm x 6 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) complete as required.
24.1.4 Earthing with tinned copper earth plate 600mmx600mmx3mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) etc. complete as required.
24.1.5 Extra for charcoal or coke and salt for G.I. plate or copper plate earth electrode.
24.1.7 Supplying and laying 25mm x 3 mm G.I. strip in 40 mm dia,GI pipe as/from earth electrode including soldering etc. as required.
24.1.9 Providing and fixing 25 mm x5 mm copper strip in 40 mm dia G.I. pipe from earth electrode as required.
24.1.10 Providing and fixing 25 mm x 5mm copper strip on surface or in recess for connections etc. as required with all labour and material.
24.1.14 Supply and erection of 20mm x 3 mm thick GI, tape fixed with suitable G.I. stapples of same size.
24.1.16 Supply and erection of 25mm dia 1.5 metre long lightning GI. tube rod tapered into a point at the top with 16cm x 16cm x 3mm thick G.I. base plate and necessary nuts and bolts with washers.
24.1.17 Providing and fixing testing joints made of 20mm x 3mm thick G.I. strips 125 mm long with 4 nos. G.I. bolts and nuts with washers complete.
24.2.6.1 Supply and erection of copper lugs including crimping etc. entire satisfaction of Engineer-in- Charge of the work. 1.5 sqmm
24.2.7.2 Supply and erection of suitable compression type brass cable glands for underground Cable :- 10 sqmm to 16 sqmm Cable 2 to 4 Core
24.2.7.3 25 sqmm to 50 sqmm Cable 2 to 4 Core
24.2.7.5 120 sqmm to 185 sqmm Cable 3 to 3½ Core
24.2.7.6 240 sqmm to Cable 3 to 3½ Core
24.2.7.7 300 sqmm to 400 sqmm Cable 3 to 3½ Core
24.2.8.4 Supply and erection of aluminium lugs heavy duty including crimping etc. upto the entire satisfaction of the Engineer- in-charge of the work. 16 sqmm
22.2.10 Supply and erection of cable route marker made of 50 cm long 10 mm dia M.S. Rod welded/revitted at the top with 10 cm dia 3 mm thick MS plate inscribed with 'cable' word on it, having a cross arm 30 cm long of the same dia welded at the bottom, in exiting trench 45 cm below ground level.
24.5.2.7 S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Mtr below ground level including diging and refilling of earth including cost of suitable size socket/cuppler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 180/150 mm outer dia/ inner dia
DSR Items. 3.8.1 Supplying, installing on wall, testing and commissioning of following capacity Air Insulated Compact Type Rising Mains for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply with enclosure having IP-54 rating after fixing the tap off boxes and all accessories, made of 1.6mm thick steel sheet duly powder coated in convenient sections complete with 4 Nos aluminium bus bars having current density of 130 A/ sq cm at nominal current rating, necessary joints & expansion joints, fire barrier at each floor, provision of tapping at every metre, continuous earthing with 2 Nos aluminium strip of suitable size (one on each side) including, G.I. clamping brackets, angle iron bracket, steel fasteners, connecting to earthing system etc. as required 200 A Isc = 15kA for 1 second
3.8.3 400 A Isc = 30kA for 1 second
3.11.1 Supplying, installation, testing & commisioning of following capacity End Feed Unit for the existing Air Insulated Compact Type bus trunking/ rising mains for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick steel sheet enclosure (IP54) duly powder coated with provision of MCCB/ACB (but without MCCB/ACB) complete with necessary joints including clamping brackets, angle iron bracket, steel fasteners, connecting to earthing system etc. as required 200 A 15kA SC for 1 sec
3.11.3 400 A 30kA SC for 1 sec
3.12 Supplying, installation, testing & commisioning of following capacity Plug In/ tap off box on the existing Air Insulated Compact Type bus trunking/ rising mains for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick sheet steel enclosure (IP54) duly powder coated with provision of MCCB/ACB (but without MCCB/ACB) complete etc. as required 125 A 15kA SC for 1 sec
6.14 Providing and laying G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required
NS Items Supply and erection of under ground Aluminum Armoured cable XLPE insulated loose in existing pipe or trenches complete with necessary connection. Make RR / Havells / Polycab. 300 Sqmm 3.5 core
240 Sqmm 3.5 core
120 Sqmm 3.5 core
50 Sqmm 3.5 core
25 Sqmm 4 core
16 Sqmm 4 core
Supply and erection of under ground Aluminum Armoured cable XLPE insulated including laying 0. 75 metre below ground level covered with sand and bricks including excavation and refilling of trenches. 300 Sqmm 3.5 core
240 Sqmm 3.5 core
120 Sqmm 3.5 core
25 Sqmm 4 core
Main Light Load PANEL Supply, installation, testing and commissioning of powder coated of Siemens grey or of approved colour compartmentlised cubicle MV Panel confirming to IEC 61439-1&2, Rated Impulse Voltage- 12 KV, IK10 Class, Form of Seperation - 3b fabricated out of CRCA sheet steel with chemical wash after 7 tank process and suitable for operation on 415 volts, 50Hz, 3 Phase 4 wire AC supply . The panel shall be indoor free standing, floor mounting, dust and vermin proof type, adeqate size cable alley with front operated rotary handles for MCCB's complete with gland plates, lifting hooks, ventillating louvers, busbars, Inter connections, earthing, labelling electrical interlocking as per specification and drawings, suitable for termination of cables as per single line diagram including. supply and fixing of following switchgear and accessories complete as required.A separate earth copper bus bar of size as per transfarmer load to be provided throughout the length of the panel. The panel should be complete with both Electrically & mechanically interlocking fool proof system.Programmable logical controller(PLC Based) AMF. The Panel should be extendable type. Make of panel- ABB (Artu), L&T (Ti), Schneider (Prisma), Siemens (Sivacon) Note:- The cost of MCCBs, MCBs are not included in the panel's cost and will be paid under separate head on HSR-BASE but the KA Capacity of MCCBs will be as per Requirement. Ritary handle with interlook are included in panel cost. All acccessories included in the panel cost such as Spreader link capacitors and its accessories & metering etc. and cost of ACBs are also included in the panel cost. Detailed specifications and material list attatched. The panel should be got tested from the Engineer-in-charge of the work in the factory premises before brought at site of work. INCOMER FEEDER Air circuit breaker 800 Amp, 415V, 50Hz, EDO 4P Icu=Ics=Icw=50KA (1 Sec) with inbuilt Microprocessor based release with LSIG Protections, Current & Voltage display on screen, Last 10 trip history on display Make of ACB : ABB, Schneider, Siemens , L&T =01 No. MFM EM6400NG Class 1.0 RS485 Port =01 Nos. RYB Indication Lamp LED= 6 Nos. 800/5Amp. 15 VA CL-1 Current Transformer 06Amp. Control SP MCB OUTGOING FEEDERS FP MCCB 400 A, Ics= 36 KA, for outgoing DG panel =01 No. Spreader links for 400Amp MCCB =01 No. Extended Rotary Handle =01 No. FP MCCB 100 A, Ics= 25 KA, for X-ray and spare = 02 No. Spreader links for 100Amp MCCB =02 No. Spreader links for 100Amp MCCB =02 No. Extended Rotary Handle =02 No. FP MCCB 32 A Ics=25 KA for Pump, Sewage =02 Nos. Spreader links for 32Amp MCCB =02 Nos. Extended Rotary Handle =02 Nos. FP MCCB 315 A, Ics= 36 KA, for APFC and power load Nitch A&B =03 Nos. Spreader links for 315Amp MCCB =03 Nos. Extended Rotary Handle =03 Nos. Note:- All MCCB should be Ics= 100%Icu. MCCB above 250A should be with Microprocessor based release with LSIG . MCCB upto 250A must be with Thermal Magnetic release with variable overload setting 0.7-1.0 Ir (Make of MCCB : Schneider Easypact / Siemens VL), L&T ( DSine) BUS BAR & HARDWARE Aluminium Bus Bar,Load wise Sub Feeder Bus Bar Colour Coated Heat Shrink Bus Bar sleave Nut-Bolt,Washer ,Hardware etc. as per Type Tested design of the Approved OEM WIRING & ACCESSORIES Power & Control Wiring will be (ISI 1100V) flamc smoke FRLS PVC Single Core Copper Wire,Copper Lugs, PVC Sleeve, Ferruels Numbers, Hardware & Labour etc
Supply , fixing , connecting and testing of OEM Manufactured APFC Panel 160 KVAR @ 440V with 7% detuned reactor. The stage ratings shall be 2 X 5 KVAR + 2X 25 kVAr + 2 X 50 KVAR, The APFC Panel shall be fully type tested and shall comply to IEC 61439-1 and IEC 61921. The APFC Panel shall be (Indoor) type, weather, dust and vermin proof suitable for humidity up to 95%. Average daily temperature: +35°C max, Ambient temperature: -5°C to 40°C, Maximum altitude: 2000 m. Approved Makes- ABB, Schneider, Legrand, L&T As equipment shall be comprising of the following:- (A) Insulated bus bar assembly made from Aluminium and rated of 400 Amps capacity. The short circuit withstand capacity shall be 50 KA / 1 Sec ( Icw) for the main bus bar and the rated impulse withstand voltage shall be 6 KV. ( B) The incomer of the APFC Panel shall be a 320 Amp, MCCB, 3P, 50kA TMD type with O/L & S/C protection, Ics = 100% Icu, MCCB shall have standard extended rotary handle, spreaders, phase barrier. . Make:- Schneider Electric / ABB / Legrand. (C) Capacitor Units : The capacitor unit shall be metalized polypropylene film with Zn / Al alloy. The capacitors shall be encapsulated in an aluminium can. The capacitor unit shall have a rated voltage of 440V and shall have a maximum over current capacity of : 1.8 In. The capacitor unit shall have a built in 3 phase over pressure protection and shall have discharge resistors ( 50V in 1min ) factory fitted and shall be tamper proof. Capacitance Tolerance -5%, +10%. Maximum permissible over voltage 1.1 x Un, 8 h every 24 h. The capacitor unit shall be of certified design confirming to IS-13340-1993,13341-1992. Make – Schneider Electric / ABB / Legrand / L&T / Naptune / Epces (D) Short-circuit and Overload Protection : Each stage of the APFC Panel shall have a suitably rated MCCB for short-circuit and overload protection. The over-current setting shall be adjustable & Breaking capacity Ics=> 36kA . The MCCB shall be of certified design confirming to IS Make:- Schneider Electric / ABB / Legrand / L&T. (E) PF Regulator : Advanced Range PF Regulator shall have 8 steps with a LCD Display, Voltage Range : 90V - 550V, 50 / 60Hz, CT Input : 1A/5A with a built in RS 485 communication port. The PF Regulator shall be of certified design confirming to IS. Make : Schneider Electric / ABB / Legrand / L&T / Naptune. (F) Stage Contactor & reactor : The electromagnetic contactors shall be rated for 660 Volts and shall be 3-pole type and shall be employed for switching 'on' and switching 'off' operations in capacitor banks. Supply to capacitor should be through 7% Aluminium wound detuned reactorThe rated voltage of control coil shall be 415V (phase-to-phase). This voltage is subject to a variation of (+) 10% and (-) 15%. The contactor shall be AC3b type. The contactor shall be of certified design confirming to IS. Make – Schneider Electric / ABB / Legrand / L&T / Naptune. (G) Ventilating fans of required size shall be sued to dissipate the heat produced by the capacitor bank components like the capacitor units, reactors, contactors, breakers etc. The capacitor banks should be of type tested design and temperature rise test report of the capacitor bank performed at an independent laboratory should be submitted along with the offer.
Supply & Erection of fire buckets of 9 ltr. capacity made out of 24guage G.l sheet and duly painted with one coat of red oxide and 2 coats of approved paint in red colour and written with the fire' as per fire protection necessar sand filling in the bucket hung the bucket on stand with all labour and material required to complete the job all respect up to entire \satisfaction of the Engineer m charge of the work
Supply and erection of lumineous bell indicator complete including making necessary connections and fixing the same on wall etc. to complete the job in all respect.
Chopta Offset Printers
Som Nath Contractor
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .