Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.7 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹28.8 L+₹93,975.70 (3.37%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹29.4 L+₹1.5 L (5.28%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹30.8 L+₹2.9 L (10.4%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST | |
| 5 | L5₹31.1 L+₹3.2 L (11.6%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN LOWEST |
| Sl No | Description | Qty | Unit | M/S RAKESH TRADERS L3 | RAJPATI CONSTRUCTION L6 | SHIV SHANKAR MISHRA L8 | PADAMSHRI CONSTRUCTION CO L5 | JYOTI ENTERPRISES L7 | M/S Shanti Traders L1 | CREATIVE CONSTRUCTION L2 | M/S AJAY JAIN L4 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00Note :(i) Please refer Sch A/ BOQ Notes before quoting the tender for all phases/ items mentioned below. (ii) Amount of Schedule of credit shall be deducted offline | |||||||||||
| 1.10 | Excavation in trenches n.exc 1.5m deep and n.exc 1.5m wide for foundation etc or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n. exc 1.5 m in depth and getting out in soft/loose soils complete all as specified and directed. | 265 | Cum | 200 ₹53,000 | 150 ₹39,750 | 400 ₹1,06,000 | 100 ₹26,500 Lowest | 180 ₹47,700 | 200 ₹53,000 | 120 ₹31,800 | 150 ₹39,750 |
| 2.00 | Demolition and breaking up 300 mm drain pipes (salt glazed ware, AC or Reinforced concrete) set in cement mortar/concrete complete all as specified and directed. | 250 | RM | 25 ₹6,250 | 3 ₹750 Lowest | 20 ₹5,000 | 30 ₹7,500 | 50 ₹12,500 | 12 ₹3,000 | 10 ₹2,500 | 10 ₹2,500 |
| 3.00 | All as per item no. 2.00 here-in-before but for 200 mm dia pipe. | 175 | RM | 25 ₹4,375 | 2 ₹350 Lowest | 20 ₹3,500 | 20 ₹3,500 | 70 ₹12,250 | 14 ₹2,450 | 10 ₹1,750 | 5 ₹875 |
| 4.00 | S&F of class SN-8 structural wall polyethylene nomial size 300 mm dia (pipe with online coupler and elastomeric rubber ring) with hollow annular smooth outer surface and a smooth inner surface (double wall plain) for non pressure underground drainage and sewage application type B, made of polyethylene (PE) material confirming to IS:16098 (Part II : 2013) and to be transported handled installed and joined as per Annex A of IS: 16098 (part II : 2013) complete all as specified and directed. | 250 | RM | 980 ₹2,45,000 | 1,500 ₹3,75,000 | 1,200 ₹3,00,000 | 1,160 ₹2,90,000 | 1,250 ₹3,12,500 | 600 ₹1,50,000 Lowest | 1,200 ₹3,00,000 | 700 ₹1,75,000 |
| 5.00 | All as per item no. 4.00 here-in-before but for 200 mm dia pipe. | 185 | Rm | 580 ₹1,07,300 | 650 ₹1,20,250 | 1,000 ₹1,85,000 | 550 ₹1,01,750 | 650 ₹1,20,250 | 500 ₹92,500 | 490 ₹90,650 Lowest | 500 ₹92,500 |
| 6.00 | M&L for returning, filling in, any type of soil including spreading, levelling, watering and well ramming in layers n.exc 25 cm complete all as specified and directed. | 200 | Cum | 40 ₹8,000 | 30 ₹6,000 | 50 ₹10,000 | 300 ₹60,000 | 40 ₹8,000 | 25 ₹5,000 Lowest | 80 ₹16,000 | 70 ₹14,000 |
| 7.00 | M&L for removing excavated material exc. 500 m but n.exc. 1.5 km and depositing where as directed at a level n.exc 1.5 mtr above the starting point complete all as specified and directed. | 165 | Cum | 60 ₹9,900 | 120 ₹19,800 | 50 ₹8,250 Lowest | 100 ₹16,500 | 100 ₹16,500 | 50 ₹8,250 Lowest | 75 ₹12,375 | 60 ₹9,900 |
| 8.00 | M&L for demolition of brick work, built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed. | 1.5 | Cum | 200 ₹300 | 60 ₹90 Lowest | 200 ₹300 | 100 ₹150 | 100 ₹150 | 200 ₹300 | 200 ₹300 | 200 ₹300 |
| 9.00 | M&L for fly ash brick work with modular bricks straight or curved on plan exc. 6 m mean radius, built in CM 1:6 complete all as specified and directed. | 18.7 | Cum | 6,000 ₹1,12,200 | 5,300 ₹99,110 | 5,500 ₹1,02,850 | 4,300 ₹80,410 Lowest | 5,400 ₹1,00,980 | 5,000 ₹93,500 | 6,900 ₹1,29,030 | 5,500 ₹1,02,850 |
Tender Value
₹43.6 L
EMD Value
₹87,200
Closing Date
14 Jul 2025, 6:00 pmClosed
GE BHOPAL
GE BHOPAL BAIRAGARH BHOPAL
SPECIAL REPAIR OF AGNIVEER OTM AND DINING HALL SEWAGE LINE AT BLDGS P 462 P 463 P 464 P 465 P 466 P 467 P 468 P 469 P 478 P 479 P 480 P 481 AT 4 TECH TRG BN AND PROVN OF 1 BAGGAGE ROOM FOR AGNIVEERS UNDER GE BHOPAL
2025_MES_715168_1
8386/E8
Open Tender
Civil Works
Item Rate
183 days
BHOPAL
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE BHOPAL
₹87,200
Yes
26 Sept 2025
18 Jun 2025
16 Jul 2025
18 Jun 2025
14 Jul 2025
2 Jul 2025
Amount
Note :(i) Please refer Sch A/ BOQ Notes before quoting the tender for all phases/ items mentioned below. (ii) Amount of Schedule of credit shall be deducted offline
Excavation in trenches n.exc 1.5m deep and n.exc 1.5m wide for foundation etc or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n. exc 1.5 m in depth and getting out in soft/loose soils complete all as specified and directed.
Demolition and breaking up 300 mm drain pipes (salt glazed ware, AC or Reinforced concrete) set in cement mortar/concrete complete all as specified and directed.
All as per item no. 2.00 here-in-before but for 200 mm dia pipe.
S&F of class SN-8 structural wall polyethylene nomial size 300 mm dia (pipe with online coupler and elastomeric rubber ring) with hollow annular smooth outer surface and a smooth inner surface (double wall plain) for non pressure underground drainage and sewage application type B, made of polyethylene (PE) material confirming to IS:16098 (Part II : 2013) and to be transported handled installed and joined as per Annex A of IS: 16098 (part II : 2013) complete all as specified and directed.
All as per item no. 4.00 here-in-before but for 200 mm dia pipe.
M&L for returning, filling in, any type of soil including spreading, levelling, watering and well ramming in layers n.exc 25 cm complete all as specified and directed.
M&L for removing excavated material exc. 500 m but n.exc. 1.5 km and depositing where as directed at a level n.exc 1.5 mtr above the starting point complete all as specified and directed.
M&L for demolition of brick work, built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed.
M&L for fly ash brick work with modular bricks straight or curved on plan exc. 6 m mean radius, built in CM 1:6 complete all as specified and directed.
M&L for 15 mm thick rendering in cement mortar on fair faces of brick work or concrete surfaces mixed with water proofing compound as per manufacturer's instruction and finished even and smooth without using extra cement complete all as specified and directed. Note:- Water proofing compound shall be measured and paid seperately under appropriate item as "supply only".
Demolition of cement concrete in ground floor, (unreinforced) paving n.exc 15 cm thick (below or above ground level) including tiling if any complete all as specified and directed.
M&L for cement concrete 1:4:8 type D-2 (using 40 mm graded stone aggregate) as in foundation, filling, sub base and mass concrete complete all as specified and directed.
M&L for PCC 1:2:4 type B1 (using 20 mm graded stone aggregate) as in lintels upto 1.5 m clear span, cills, steps, seismic and other similar bands, coping, benching, kneelers, apex stones, bed plates, kerbs and the like including weathering, slightly rounded or chemfered angle and throating, complete all as specified and directed.
Extra for forming fair finished drain or channel exc. 0.75 but n exc 0.9 cm inner girth in cement concrete using extra cement complete all as specified and directed.
Use and waste of form work to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams, walls, slabs and similar work, vertical or to batter of rough finished surfaces of flat concrete complete all as specified and directed.
Demolition of cement concrete reinforced (reinforcement cut as required to facilitate demolition) in any description and in any position not other wise specifically provided for complete all as specified and directed.
M&L for reinforced cement concrete (Design mix M-25) in type B1, 1 : 2 : 4 (using 20 mm graded stone aggregate) as in walls, retaining walls, basement walls, ballast walls and the like, any thickness, above top of footings, including attached pilaster and buttresses complete all as specified and directed.
M&L for reinforced cement concrete (Design mix M-25) type B1, 1:2:4, (using 20 mm graded stone aggregate) in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed.
M&L for reinforced cement concrete (Design mix M-25) type B1 1:2:4 (using 20 mm graded stone aggregate) in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
M&L for mild steel, TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
All as per item no. 20.00 here-in-before but for 6 to 8mm dia.
M&L for mild steel round bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips of Fe-410 W Gde , E-250 quality A complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
M&L for precast cement concrete type B1 (using 20 mm graded stone aggregate) as in cover slab for manholes etc set in CM 1:4 including form work or moulds etc. complete all as specified and directed.
Taking down eaves gutters and rain water pipes (any size or pattern), including all fittings, heads, shoes, bends, swan necks, etc including cleaning, refixing or removal to store complete all as specified and directed.
S&F in repairs 110mm PVC(SWR) pipes, single socketed in any length with rubber rings joints laid in trenches including clamps complete all as specified and directed.
All as per item no. 26.00 here-in-before but for fixed to walls.
S&F of 110 mm PVC(SWR) bends, any radius complete all as specified and directed.
Excavating over areas, exc 1.5 m but n. exc 3 m deep and getting out in hard / dense soil complete all as specified and directed.
M&L for CI sand cast vent pipes 200 mm dia including cowl, fitting with wire mesh with cement joints fixed to walls complete all as specified and directed.
Dismantling of stone slabs and tiles of any description or thickness in floors, aprons etc laid bedded and pointed in any mortar complete all as specified and directed.
M&L for machine pressed precast concrete interlocking paver block any shape and size confirming to IS:15658 -2006 of 60 mm thickness, M-35 grade with grey cement and pigment for path etc complete all as specified and directed.
M&L for sand filling under floors or in foundations including watering and consolidation for sand cushioning for paver block complete all as specified and directed.
M&L for size 1200mm x 600 mm (4' x 2' ), machine cut kota stone slab flooring 20-25mm thick over cement screed bed in CM 1:4 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including making the edges bullnosed and rubbing and mirror polishing complete all as specified and directed.
M&L for hardcore of broken stone or boulders of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L for 75 mm thick PCC 1:3:6 type C2 (using 40 mm graded aggregate) in plinth protection, aprons, hard standing, path and like including finishing the surfaces even and smooth without using extra cement complete all as specified and directed
M&L for moorum filling brought from outside MD land with any lead, including spreading, levelling, watering & well ramming, in layers not exc 15 cm each complete all as specified and directed.
Cutting into existing manholes/septic tanks for connecting new drains, making good to pipes and rendering, cutting out existing benching for forming branch channel (1/2 round or 3/4 section ) in cement concrete 1:2:4 type B1 using 20mm graded stone aggregate, smooth finished, and reforming benching as required dia 150 mm complete all as specified and directed.
M&L for providing precast cement concrete louvres and jallies, 1:2:4 type B-0 (12.5 mm graded stone aggregate) set in CM 1:4 of 25mm thick (measured solid), including all mouldings but excluding frame (Pre cast frame shall be measured separately and paid for under respective item complete all as specified and directed.
M&L for frame work such as grills, gratings, railings, jali, frame work conforming to Fe-290, Gde E-165 as in MS jali/grating, manhole cover frame and the like including necessary drilling, welding, bolting to frame etc complete all as specified and directed.
Earth work in excavation by mechanical means (Hydraulic excavator) means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 Sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5m, complete all as specified and directed.
M&L for nominal mix 1:2:4 (using 20 mm graded stone aggregate) as in foundations, including rafts, footings, foundation beams, plinth beams, base for columns and mass concrete etc. complete all as specified and directed.
M&L for nominal mix 1:2:4 (using 20 mm graded stone aggregate) as in coloumns, pillars, piers, posts and struts etc. complete all as specified and directed.
M&L for nominal mix 1:2:4 (using 20 mm graded stone aggregate) as in beams, cantilevers bressummers, lintel over 1.5 m span etc. complete all as specified and directed.
M&L for nominal mix 1:2:4 (using 20 mm graded stone aggregate) as in Chajjas complete all as specified and directed.
M&L for nominal mix 1:2:4 (using 20 mm graded stone aggregates) in slabs supported on walls, beams and columns complete all as specified and directed.
M&L for use and waste formwork for to sides of pillar, post, struts, pier column rough finished surfaces of concrete rough finished surfaces of concrete complete all as specified and directed.
M&L for use and waste formwork to chajjas including edges for rough finished surfaces of concrete complete all as specified and directed.
M&L for use and waste formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. complete all as specified and directed.
M&L for use and waste formwork to fair finished soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (horizontal or sloping) complete all as specified and directed.
M&L for mild steel TMT bars 5 mm and over upto and including 10 mm dia, as in stirrups, spacers and binders, cut to length bent to shape as required including cranking bending spirally for hoping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
M&L for treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured) complete all as specified and directed.
M&L for treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed.
M&L for treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed.
M&L for cement concrete type B-0, 1:2:4 (using 12.5mm graded stone aggregate) 25 mm thick as in levelling course in floors complete all as specified and directed.
S&F of grid 605 x 605mm anodised aluminium snap grid frame work for false ceiling complete all as specified and directed.
M&L for providing and fixing Gypsum Board 12mm thick in ceiling fixed with screw on frame work complete all as specified and directed.
S&F of prepainted galvalume aluminum zinc coating GI based corrugated steel sheeting 0.50mm thick (AZ-150) of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, chajjas, fixed with self tapping screws/J-type bolt/L-type bolt complete all as specified and directed.
S&F of rolled mild steel work as in rafter, purlins, trusses and like (beam, tee, angle, channel or flat sections (Fe 410-W(Gde E-250 quality) complete all as specified and directed.
M&L for brickwork with flyash bricks, straight or curved on plan to any radius in half brick thick walls, built in cement mortar 1:6 complete all as specified and directed.
M&L for rendering 10 mm thick in CM (1:6) on fair faces of brick work or conrete surfaces/stone masonary and finishing the surfaces even and smooth without using extra cement complete all as specified and directed.
Supply only integral water proofing compound, ISI marked complete all as specified and directed.
M&L for 5mm thick rendering in cement mortar 1:3 on concrete surfaces as in ceiling including finishing the surfaces even and smooth without using extra cement complete all as specified and directed.
M&L for preparation of newly plastered sufaces of walls and finishing walls with two coats of textured paint of required shade (Two coats applied @ 3.28 ltr/10 sqm) over and including priming coat of primer applied @ 2.20kg/10 sqm complete all as specified and directed.
M&L for preparation of newly plastered or unplastered surface of ceiling and applying three coats of white wash complete all as specified and directed.
S&F of factory made solid PVC Moulded door shutter with particle board core, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick moulded PVC sheet on the front face and 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification and drawing complete all as specified and directed.
S&F Solid PVC door frame of size 50 mmx 47mm made out of 5 mm plain colour PVC sheet reiforced with MS square tube and fixing in opening as per manufacturer instruction complete all as specified and directed.
S&F aluminium alloy, anodized sliding door bolt of 250mm length with hasp and staple (Bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolt of extruded section or cast aluminium alloy complete all as specified and directed.
S&F of butt hinges, medium weight, mild steel, 100mm size complete all as specified and directed.
S&F of aluminum handles, cast type, anodized of 150 mm size complete all as specified and directed.
S&F of aluminum anodised barrel tower bolt 150 mm, extruded section and fixed complete all as specified and directed.
S&F of powder coated aluminium sections fabricated work as in doors, windows, partition as per manufacturer instruction including necessary jointing cleats, anodised aluminium snap beading including taking down damaged portions of damage doors, windows or taking down door/window complete all as specified and directed.
S&F of 4 mm thick, sheet glass and glazing with beading including rubber packing surrounds complete all as specified and directed.
S&F of 4 mm thick, frosted glass and glazing with beading including rubber packing surrounds complete all as specified and directed.
S&F of vitreous china wash down water closed pan (Pedestal pattern), white (excluding flushing cistern and flush pipe) and including plastic seat cover with aluminium hinging device complete all as specified and directed.
S&F of syphonic action type, PVC low level flushing cistern of 10 ltrs capacity including 32mm dia flush pipe and pipe including PVC connection 600 mm long 15 mm bore with brass heads and washers with connections fixed in repairs complete all as specified and directed.
S&F of 15 mm bore bib taps, cast copper alloy, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferulle and fixed complete all as specified and directed.
S&F of 15 mm bore stop cock, cast copper alloy, chromium plated with long shank and cut (angle cock), screwed down, screwed for iron pipe or union complete all as specified and directed.
S&F of vitreous china urinal, half stall type, white including waste pipe and CP urinal spreader complete all as specified and directed.
S&F of wash basins, vitreous china (flat back or angle back type) 630x450 mm size, including cutting for and pinning in ends of brackets or erecting stand/supported on wall, fixing and supply of waste pipe, waste coupling including 15 mm dia pillar taps cast copper alloy with capstan head chromium plated, screwed down high pressure, with or without lettered hot or cold with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed.
S&F of PVC connection 15 mm size with PTMT nuts of length 600 mm complete all as specified and directed.
S&F of brass chromium plated tubular towel rail, 20mm dia, D-type, 60cm long between flanges, complete all as specified and directed.
S&F of 20 mm bore GI tube, medium grade, with all necessary fittings and fixed complete to wall and ceiling or laid in floors complete all as specified and directed.
S&F of 15 mm bore, GI tube, medium grade, with all necessary fittings and fixed complete to wall and ceiling or laid in floors complete all as specified and directed.
S&F of 100mm dia CP grating complete all as specified and directed.
S&F of liquid soap container of PTMT fixed with and including chromium plated brass screws and wooden/plastic cleats (minimum weight 105gms) complete all as specified and directed.
S&F of 75 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed in walls / laid in trenches/floors complete all as specified and directed.
S&F of 75 mm dia PVC (SWR) bends any radius complete all as specified and directed.
S&F of 75mm dia, PVC (SWR) floor/nahani trap with grating including jointing with solvent cement complete all as specified and directed.
S&F of PVC (SWR), gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified and directed.
S&F of 75 mm bore PVC (SWR), vent cowl complete all as specified and directed.
S&F of health faucet (ABS Body), mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified and directed.
M&L for provn of APP based polymeric membrane minimum weighing 3Kg/Sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface by forced application complete all as specified and directed with followings:-
(a) 10 mm thick plaster in CM 1:4 mixed with and including water proofing compound @3% by weight of cement applied over roof slab. After the plaster is cured the roof will be tested for water tightening by ponding with water for seven days for any seepage / leakages etc. if any seepage is oberved the rectification will be carried out by pressure grouting under the pressure of 5 Kg/Sqcm using cement based cement grout. After the surface is repired the slab will be tested for watertightness aginst before processing further treatments. (WPC will be paid seperatly)
(b) The surface of the roof, parapet and gutters, drain mouths etc. over which water proofing treatment is to be applied shall be cleaned of all foreign matters such as fungus, mass, dust etc. by wire brushing and dusting. For cast iron drain outlets the grove shall be cut around to tuck in the treatment as pipes, chimney stacs etc. and other similar situations to ease up about corners.
(c) Bituminous primer conforming to IS : 3384-1965 @ 0.30 Kg/Sqm to be applied an prepared surface till the surface is properly impregnated.
(d) APP modified water proofing membrene as specified shall be laid on the primer surface by torch application method as per manufacturers instructions, The overlaps while torching shall be 100 mm in longititudinal edges and 150 mm at the ends. All overlap joints shall be sealed throughly by thermofusing both the membrene layers and sealing it with the help of hot trowel. The overlap joints shall be made as monolithic layer.
(e) Ponding test will be carried uot 72 hrs.
M&L for vitrified ceramic coloured (dark), double charged, tile 8-10mm thick(square/rectangular) polished, area of each tile not exceeding 0.36 Sqm as in floors over and including 15 mm thick screed bed in CM 1:6 etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shades of tiles complete all as specified & directed
M&L for vitrified ceramic coloured (dark), double charged, tile 8-10mm thick (square/rectangular) polished area of each tile not exceeding 0.36 Sqm on vertical surfaces such as skirting, dado and risers to steps etc over and including 10 mm thick rendering in CM 1:4 set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
M&L for non skid ceramic coloured tiles 7mm to 8 mm thick (square /rectangular) area of each tile exceeding 0.11 Sqm, but not exceeding 0.18 Sqm, in floors over and including 15mm thick screed in CM 1:6 etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shades of tiles complete all as specified and directed.
M&L for coloured glazed ceramic tiles in vertical surface 350 x 250 x 7 mm/ 450X350X7mm thick set and jointed over and including 10 mm thick rendering even and rough in CM1:4 for backing of tiles, jointed in neat cement slurry and pointed in white or colour cement to match the shade of tiles complete all as specified and directed.
M&L for granite work (any type) 18 to 20 mm thick (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms, counter, shelves and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including over 15 mm thick screed bed in CM 1:4 complete all as specified and directed.
Earth work in excavation in any type of soil by mechanical means (Hydraulic excavator)/ in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil within a lead of 50m complete all as specified and directed.
M&L for brickwork with fly ash bricks in one brick thick honey-comb walling, built in cement mortar 1:6 complete all as specified and directed.
M&L for point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits), with multi-stranded stranded copper conductor 1.5 Sq. mm nominal cross-sectional area, single core, PVC insulated and unsheathed FRLS cable 1100 volts grade, ISI-694 marked with valid CML No. in and including medium grade, PVC concealed conduit and conduit accessories concealed in wall/roof/floor etc, ISI marked with valid CML No.(IS-9537-1983 for conduits and IS:3419:1976 for conduit accessories), with mild steel/pressed steel sunken boxes( with earth dolly) duly painted with two coats of anti corrosive paint/aluminium paint over a coat of red oxide primer internally, and two coats of black bituminous paint over a coat of red oxide primer externally, covered with 3 mm thick plastic laminated sheet cover for fixing of switches, sockets and fan regulators etc, including PVC insulated multi-stranded copper conductor 1.5 Sq mm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed at site for the following:-
(a) One light point /fan
(b) One 3 pin socket outlet 5 Amps on independent board
(c) One 3 pin socket outlet on same board
All as per item No. 103.00 here-in-before but wiring with 2.5 Sq mm copper conductor cable for 5/15 amp switch socket combination on independent board and provision of 2.5 Sqmm, FRLS insulated multi-stranded single core earth wire for earth continuity, connected to common earth dolly.
S&F in repairs modular switch 1 way 5A, 1 module, ISI marked complete all as specified and directed.
S&F in repairs socket, 6A - 2/3 pin combined 2 module, 1 module, ISI marked complete all as specified and directed.
S&F of ceiling rose surface bakelite 65mm dia three terminal complete all as specified and directed.
S&F of modular metal flush box of 4 module, ISI marked complete all as specified and directed.
S&F of modular white cover plate of 4 module omplete all as specified and directed.
S&F in repairs white cover plate with frame, 8 module, ISI marked complete all as specified and directed.
S&F in repairs metal flush box 06 module, ISI marked complete all as specified and directed.
S&F of sheet metal enclosure for MCB, DB, SPN, 240 Volts, 200 amps rated busbar, 8 way Double door enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43 including wooden rectangle board of first quality of suitable size for mounting of DB box complete all as specified and directed.
S&F in repairs 5 to 32 Amps MCB 'B' single pole 240 V complete all as specified and directed.
S&F in repairs MCB single pole with neutral 240 volts 6 to 32 Amps complete all as specified and directed.
S&F in repairs lamp holder, PVC/Poly carbonate type with back plate suitable for batten fittings including 9 watt LED lamp and all connected accessies complete all as specified and directed.
S&F of 200 mm exhaust fan, steel body AC single Phase 230V of size 300m sweep with, blades, and frame and louvers complete all as specified and directed.
S&F of ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep, min air delivery 210 CFM with service value 6.00 BEE, five star rated with brushless direct current motor (BLDC) including down rod extended upto 6 feet length complete all as specified and directed.
S&F of LED tube light fitting, 1 x 20 W, 240 V, luminaire with bipin holders, LED tube rod, connector block, etc complete with all accessories internally pre-wired and including connecting up with three core twisted flexible copper conductor cable with suitable size complete all as specified and directed.
S&F of LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
S&F of building security light including GI Pipe of approx 1 mtr length and suitable size of led light of capacity 25 watt including weather protection cover nut, bolt and connected accessories complete all as specified and directed.
S&F of single pole and neutral enclosure with two pin and earth, plug and socket, suitable for single phase 240 V, complete with one single pole MCB of capacity 20 amps having `C` charactristic, breaking cap 10 KA, including industial plug top complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode size 600x600x6mm thick burried directly in ground vertically in a pit of depth not less than 2.25 mtr below ground levels with top edge of the earth plate not less than 1.5 mtr below normal ground level surrounded from all sides by mixture of charcoal and common salt and electrode connected to and including galvanised iron wire 4 mm earth lead by means of bolts, nuts, check nuts and washers of galvanised steel and GI pipe, light grade, 20mm dia bore for watering funnel with wire mesh, CI cover with frame, PCC chamber pit with PCC 1:3:6 type C-2 using 40mm graded stone aggregate, excavation and earth work all as shown in electrical plate No 3 connected to earthing test point all as specified or indicated including testing on completion. Notes:- The unit rate includes for protection pipe and GI strip dia from top of earth plate upto 5.00 meter above ground level.
Supply, Laying, commissioning and testing of UG LT cable XLPE insulated screened PVC bedded, galvanized steel strip armored, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor of size 10 sqmm 2 core complete all as specified and directed.
Supply, fixing and laying in repairs GI tubing of 25mm, medium grade, with one socket both end threaded in any length including cutting threading connection in new or old position and all type of GI new fittings for laid in trenches/wall/ceiling/ floor complete all as specified and directed.
S&F of gun metal globe or gate valves, conf to IS 778 with iron wheel head, screwed both ends for iron pipe and fixed in existing or new position for following size:-
(a) 25 mm bore
(b) 20 mm bore
S&F of rotational moulded polyethylene water storage tanks of 500 ltr capacity, (cylindrical vertical with closed top) triple layer, ISI marked hoisting and fixed in position all as specified in SSR part-I complete all as specified and directed.
M&L for PTMT float valve of 20 mm bore, high pressure with high density plastic ball, with epoxy coated aluminium rod screwed for iron pipe and fixed in complete all as specified and directed.
Deduct Schedule of credit (calculation will be done off line) Rs. 17100.00
CREATIVE CONSTRUCTION (BID ID -3350093)
M/S RAKESH TRADERS (BID ID -3357642)
M/S AJAY JAIN (BID ID -3350062)
PADAMSHRI CONSTRUCTION CO (BID ID -3349652)
RAJPATI CONSTRUCTION (BID ID -3358163)
JYOTI ENTERPRISES (BID ID -3358398)
SHIV SHANKAR MISHRA (BID ID -3350384)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .