Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.6 LAccepted-AOC 1ST FLOOR BL 8 6 DR B C ROY SARANI JYANGRA BAGUIHATI KOLKATA 700059 | KOLKATA | 24 PARAGANAS NORTH | WEST BENGAL | 700059 | ₹8.6 L | L1 | Accepted-AOC AOC |
| 2 | L2₹9.1 LRejected-Finance GR 8 ADDA BUILDING 1ST FLOOR CITY CENTRE DURGAPUR 16 | DURGAPUR | PASCHIM BARDHAMAN | WEST BENGAL | ₹9.1 L | L2 | Rejected-Finance stood L2 |
| 3 | L3₹9.2 LRejected-Finance MAIRAKATA P O GARBETA DIST PASCHIM MEDINIPUR 721127 | GARBETA | PASCHIM MEDINIPUR | WEST BENGAL | 721127 | ₹9.2 L | L3 | Rejected-Finance stood L3 |
| 4 | Rejected-Technical 12 1 FERRIGHAT ROAD P O BHATPARA DIST NORTH 24 PGS WEST BENGAL PIN 743123 | BHATPARA | NORTH 24 PARGANAS | WEST BENGAL | 743123 | - | - | Rejected-Technical Uploaded shortfall documents is not applicable as per NIQ point no 15/B(iv). |
| Sl No | Description | Qty | Unit | DURGAPUR POWER L2 | M/S S. CHATTERJEE L1 | R.K.ENTERPRISE L3 |
|---|---|---|---|---|---|---|
| 1.00 | Supply, Installation,Testing & Commisioning of Microprocessor based 2 Loops fire alarm control panel fully networkable with each loop capable of taking 125 devices, 1/4 VGA display character alpha-numeric liquid crystal display.The panel shall be soft addressable type. The panel shall be able to give pin point location of all fire/fault conditions. Further, the panel must be able to automatically switch off respective control switches when ever any alarm is triggered The panel shall have in built rectifier, provision for external & internal printer (if required),Loop cards, LCD unit to indicate Fire/Fault Signal with address and analog output, complete in all respects, having 10000 event memory, integral SMF lead acid batteries with sealed cells of 24 V capable of running for a minimum of 2 hours with integral battery charger complete as required. ( Make: Siemens Cerberus Pro/ Securiton / Bosch) | 2 | Nos | 63,000 ₹1.3 L | 62,881 ₹1.3 L | 62,900 ₹1.3 L |
| 2.00 | Supply installation Testing & Commisioning of EN -54 standard VDS/LPCB Approved Addressable Multi sensor Detector (optical smoke as well as heat ) with inbulit / additional isolator and integral LED status indicator with 360 degree viewing angle Detector shall commumcate 3 danger levels for differentiated alarm activation and high tolerance to dust dirt temperature fluctuation and air currents Detector should have unquie address for communication and assigned through panel with Mounting Base as rqequired with the protection category of IP40 (Approved Make:Honeywell/Bosch / Seoutron/ Siemens) | 47 | Nos | 1,860 ₹87,420 | 1,858 ₹87,326 | 1,865 ₹87,655 |
| 3.00 | Supply, Installation, Testing & Commissioning of Intelligent Addressable EN Standards & VDS Approved Heat (Fixed Temp + ROR Temp) Detector with Base & Necessary accessories for fitting, J.B etc. (Approved Make: Siemens Cerberus Pro/ Securiton / Bosch) | 10 | Nos | 1,200 ₹12,000 | 1,157 ₹11,570 | 1,165 ₹11,650 |
| 4.00 | Supply, Installation, Testing & Commissioning of Intelligent Addressable EN Standards & VDS Approved Manual Call Point with Necessary accessories for fitting, J.B etc. (Approved Make: Siemens Cerberus Pro/ Securiton / Bosch) | 6 | Nos | 2,500 ₹15,000 | 1,157 ₹6,942 | 1,170 ₹7,020 |
| 5.00 | Supply, Installation, Testing & Commissioning of EN Standards & VDS Approved Loop Powered Sounder cum Strobe with necessary accessories for fitting, J.B etc. (Approved Make: Siemens Cerberus Pro/ Securiton / Bosch) | 7 | Nos | 3,450 ₹24,150 | 2,407 ₹16,849 | 2,470 ₹17,290 |
| 6.00 | Supply, Installation, Testing & Commissioning of Response Indicator. (Approved Make: Siemens Cerberus Pro/ Securiton / Bosch) | 1 | Nos | 155 ₹155 | 150 ₹150 | 190 ₹190 |
| 7.00 | Supply & Laying of 1.1KV grade 2nos 1.5 sq.mm PVC insulated flexible FRLS copper Cable (Make. Finolex/Mescab/KEI) for Looping.in PVC (Approve Make)conduit including Supply & Fixing of 20 mm complete with all accessories. | 1,825 | Mtr | 150 ₹2.7 L | 140 ₹2.6 L | 155 ₹2.8 L |
| 8.00 | Supply & Laying of HDPE pipe For Overhead Cable Runway (Approve Make)conduit including Supply & Fixing complete with all accessories | 305 | Mtr | 142 ₹43,310 | 139 ₹42,395 | 149 ₹45,445 |
| 9.00 | Supply and installation of Conventional type smoke detector (make: Siemens) as per direction of EIC. For SNCU Building | 10 | NOS | 830 ₹8,300 | 827 ₹8,270 | 850 ₹8,500 |
| 10.00 | Checking, Testing, Cleaning of the Smoke/Heat detectors ( approved Siemens make) devices thoroughly and refixing the same as per direction of EIC. | 390 | NOS | 195 ₹76,050 | 194 ₹75,660 | 210 ₹81,900 |
Tender Value
Refer Docs
EMD Value
₹19,900
Closing Date
1 Sept 2025, 6:55 pmClosed
EE.AED.PWD
Office of the Executive Engineer, PWD, Asansol Electrical Division,Bijoy Pal Sarani, Opposite to Polo Ground, Asansol-713304, Paschim Bardhaman.
Repair and Renovation and SITC of Fire Detection System in Durgapur SDH, Paschim Bardhaman.
2025_WBPWD_893423_1
WBPWD/EE/AED /eNIQ-05(4th Call)/2025-26
Open Tender
ELECTRICAL WORKS ORG
30 days
Durgapur
Please refer Tender documents.
4 documents required · 4 mandatory
₹19,900
Office of the Executive Engineer P.W.D. Alsanso
25 May 2026
21 Aug 2025
4 Sept 2025
21 Aug 2025
1 Sept 2025
26 Aug 2025
25 Aug 2025
Amount
Supply, Installation,Testing & Commisioning of Microprocessor based 2 Loops fire alarm control panel fully networkable with each loop capable of taking 125 devices, 1/4 VGA display character alpha-numeric liquid crystal display.The panel shall be soft addressable type. The panel shall be able to give pin point location of all fire/fault conditions. Further, the panel must be able to automatically switch off respective control switches when ever any alarm is triggered The panel shall have in built rectifier, provision for external & internal printer (if required),Loop cards, LCD unit to indicate Fire/Fault Signal with address and analog output, complete in all respects, having 10000 event memory, integral SMF lead acid batteries with sealed cells of 24 V capable of running for a minimum of 2 hours with integral battery charger complete as required. ( Make: Siemens Cerberus Pro/ Securiton / Bosch)
Supply installation Testing & Commisioning of EN -54 standard VDS/LPCB Approved Addressable Multi sensor Detector (optical smoke as well as heat ) with inbulit / additional isolator and integral LED status indicator with 360 degree viewing angle Detector shall commumcate 3 danger levels for differentiated alarm activation and high tolerance to dust dirt temperature fluctuation and air currents Detector should have unquie address for communication and assigned through panel with Mounting Base as rqequired with the protection category of IP40 (Approved Make:Honeywell/Bosch / Seoutron/ Siemens)
Supply, Installation, Testing & Commissioning of Intelligent Addressable EN Standards & VDS Approved Heat (Fixed Temp + ROR Temp) Detector with Base & Necessary accessories for fitting, J.B etc. (Approved Make: Siemens Cerberus Pro/ Securiton / Bosch)
Supply, Installation, Testing & Commissioning of Intelligent Addressable EN Standards & VDS Approved Manual Call Point with Necessary accessories for fitting, J.B etc. (Approved Make: Siemens Cerberus Pro/ Securiton / Bosch)
Supply, Installation, Testing & Commissioning of EN Standards & VDS Approved Loop Powered Sounder cum Strobe with necessary accessories for fitting, J.B etc. (Approved Make: Siemens Cerberus Pro/ Securiton / Bosch)
Supply, Installation, Testing & Commissioning of Response Indicator. (Approved Make: Siemens Cerberus Pro/ Securiton / Bosch)
Supply & Laying of 1.1KV grade 2nos 1.5 sq.mm PVC insulated flexible FRLS copper Cable (Make. Finolex/Mescab/KEI) for Looping.in PVC (Approve Make)conduit including Supply & Fixing of 20 mm complete with all accessories.
Supply & Laying of HDPE pipe For Overhead Cable Runway (Approve Make)conduit including Supply & Fixing complete with all accessories
Supply and installation of Conventional type smoke detector (make: Siemens) as per direction of EIC. For SNCU Building
Checking, Testing, Cleaning of the Smoke/Heat detectors ( approved Siemens make) devices thoroughly and refixing the same as per direction of EIC.
Supply,installation, Testing, Commissioning of Addressable Multi detector with all necessary acceessories (make:Siemens ) as per direction of EIC.
Finding disconnected device from loop cable,Auto learn and configure device,Change pmi,Upgrade pmi if needed,Configure system from Siemens software, Re-commisioning of necessary hardware and Software for Repeater fire alarm panel with necessary certificate from commisioning engineer for installed approved siemens make as per direction of EIC.
Supply, installation, Testing and Commissioning of 12 Volt 7 Amp power BATTERY with all necessary accessories. (make: Approve, as per choice of EIC)
Add GST @18% On total from item no 1 to 13.
Add LWC @1% On total from item no 1 to 14.
DURGAPUR POWER (BID ID -6883316)
R.K.ENTERPRISE (BID ID -6883377)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid