Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.3 LAccepted-AOC | L1 | Accepted-AOC Lowest and reasonable bidder | |
| 2 | L2₹18.3 L+₹97,239.92 (5.61%)Rejected-Finance BEHIND POWER HOUSE WARD NO 6 UDASAR BIKANER RAJASTHAN 334022 | BIKANER | RAJASTHAN | 334022 | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | Rejected-Technical 77 KAILASH PURI BIKANER RAJASTHAN PIN 334001 | BIKANER | BIKANER | RAJASTHAN | 334001 | - | Rejected-Technical No till change in constitution approved |
Tender Value
₹19.5 L
EMD Value
₹39,000
Closing Date
24 Dec 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Nal, Bikaner
GE (AF) Nal, AF Stn Nal Bikaner (Raj)-334001
As described in Bill of quantities
2020_MES_376751_2
GE (AF) NAL/T-23/2020-21
Open Tender
Civil Works
Item Rate
180 days
GE (AF) Nal
As per NIT and tender documents
9 documents required · 9 mandatory
₹500
GE (AF) Nal
₹39,000
Yes
GE (AF) NAL
14 Jan 2021
2 Dec 2020
26 Dec 2020
2 Dec 2020
24 Dec 2020
4 Dec 2020
2 Dec 2020 - 3 Dec 2020
3 Dec 2020
60 days
Amount
Supply, installation testing and commissioning of indoor type voltage stabilizer of capacity 200 KVA with control panel (automatic/servo voltage controller three phase 50 Hz for automatic controlling / Regulating of voltage comprising auto transformer, back and boost transformer, wiring and termination all in copper (with new filtered and dehydrated stabilizer oil, servo motor, auto controlled microproccessor based control circuit (suitable for supply from DG set also), auto and bypass arrangement other setting and accessories, digital type volt meter to read input / output voltage (415 V), Ammeter, suitable CTs and Frequency meter, Mains/low/high limit indicators, Manual increase/ dicrease push buttons, Auto / Manual mode control switch and output adjustment with the following specification as described in srl item No. 1.10 below and confirming to IS 9815 (Part -1 of 1994) :-
Excavation in trenches in soft/loose soil not exceeding 1.5 mtr wide or not exceeding 10sqm on plan, and not exeeding 1.5 m deep, getting out the excavated earth bottom surface to required gradient complte all as specified and directed.
Returning filling in, and including spreading and leveling in layers not exceeding 25 cm thick in soft / loose soil complete all as specified & directed.
Removal of excavated material such as soils to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed.
M&L sand cushioning using dry and clean tibba sand, laid in two layers in trenches / ducts, first layer of 80 mm thick before laying of cable and second layer of 150 mm thick after laying of cable including consolidation of each layers complete all as specified and directed.
Supply and laying well burnt old size sub Class ‘B’ bricks, laid flat, in trenches for cable protection complete all as specified and as directed.
Supply and laying XLPE insulated, armoured, heavy duty, 1100 Volts grade aluminium conductor cable Cross sectional area 185 Sqmm, 3.5 core in trenches or fixed to wall / passing through pipe / pole and testing compete all as specified and directed Note : (i) Excavation and earth work shall be measured and paid for separately. (ii) Brick cover protectioin and sand cushining shall be measured and paid for separately. (iii) Pipe including clamps, if required, shall also be measured and paid for separately.
All as per description of serial item No. 7 here in before but size 120 sqmm, 3.5 core.
All as per description of serial item No. 7 here in before but size 35 sqmm,3.5 core.
All as per description of serial item No. 7 here in before but size 16 sqmm, 4 core.
All as per description of serial item No. 7 here in before but size 10 sqmm, 4 core.
All as per description of serial item No. 7 here in before but size 6 sqmm, 4 core.
M&L chemical earthing complete with copper earth plate electrode 900 mm x 600 mm x 5 mm thick buried directly in ground vertically in a pit of depth not less than 3.65 metre below normal ground level with top edge of the earth plate at a depth not less than 2.90 metre below normal ground level, earth plate connected to copper strip 32 x 6 mm as earthing lead by means of brazing for a length of 45cm, copper strip protected by galvanized steel pipe 50 mm bore medium grade upto ground level and there after by 50 mm dia HDPE pipe upto test point (maximum upto 7.5metre from earth plate), earth plate surrounded by charcoal or coke and common salt upto 90 cm in alternate layers of 15cm each, thereover a layer of 60cm tibba sand duly compacted, thereafter 300 mm thick layer of magnesium sulphate powder (compacted thickness) and finally filing the top of pit upto ground level with tibba sand, to achieve earth resistance value less than 1 Ohm including provision of 20mm bore galvanised steel pipe light grade with funnel & wire mesh for watering, earth pit chamber built in cement concrete 1:3:6 type C-1 using 20mm graded stone aggregate covered with 50mm thick pre-cast cover slab of RCC 1:2:4 type B-1 duly reinforced with 8mm dia MS TMT bars @ 15cm c/c both ways, with suitable handle made of 10mm dia MS round bar, including excavation & earthwork in any type of soil / strata, removal of surplus soil to a distance not exceeding 50 metre as shown in Electrical Plate No. 3 of MES Schedule Part-I complete all as specified and directed.
Note for item No. 13.00 :- (a) Earth chamber shall be constructed minimum 0.5 metre away from earth pit. (b) On testing after completion, if the desired earth value i.e. less than 01 Ohm is not obtained, the earthing shall be re-carried out by contractor at no extra cost to the Govt. (c) The quantity of backfill material and depth of earth pit shall be added by the contractor to acheive earth resistance less than 1 ohm on completion and testing without any extra cost to Govt. (d) The rate quoted shall also include the cost of following:- (i) bronze test point of size 75mm x 75mm x 25mm. (ii) Display board of size 20cm x 15 cm made of 3mm thick MS sheet with frame and supports of angle iron 40mm x 40mm x 4mm, legs embedded in and including PCC blocks 30cm x 30cm x 15cm in 1:3:6 type C-1 incl necessary form work, earth work, painting MS work with synthetic enamel paint and marked with earth pit No. as directed. (e) The work shall be executed at locations of AF Stn Nal. Conractor shall keep this aspect while quoting his rates. The locations of earthing is kept with AGE E/M AF Nal.
Material and labour earthing complete with copper earth plate electrode 60 cm x 60 cm x 3.15mm thick, buried directly in ground, vertically to a depth not less than 3.65 mtr deep below ground level with top edge of the earth plate at depth not less than 3.05 mtr below ground level earth plate surrounded by 15 cm thick and packed layers of charcoal, dust and common salt, earth lead copper strip 32mm x 6mm connected to earth plate by brzing upto 45cm lenth, earth strip to be protected by galvanised iron pipe 40 mm bore (medium grade) up to ground level and there after with 40mm dia HDPE pipe up to test point. (7.5 metre long earth strip upto test point included in unit rate of this item.) Earthing shall include provision of funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) up to 90 cm all around earth plate further filled with 60 cm thick Tibba sand and 2nd layer with 30 cm of Magnesium sulphate powder (compact thickness ), 3rd layer with tibba sand up to ground level. Earthing shall also include concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 Mtr etc all as shown on electrical plate No. 3 of MES Schedule Part-I complete to obtain less than 2 Ohm earth resistance value, complete all as specified. NOTE : (i) Cost of this items includes the scope of earth work, charcoal, salt, PCC, RCC pit cover of required size. (ii) Tibba sand shall be arranged by the contractor at his own and the cost thereof shall be deemed included in unit quoted rate of this item. (ii) Electrical Plate No. 3 refrred in the item above is mainly for earth chamber.
M&L for earthing complete with GI earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly in ground vertical position , earth pit not less than 3.00 Mtr deep below ground level with top edge of the plate not less than 2.4 Mtr below ground level. The earth plate to be connetced with galvanised iron earthing strip of size 25 mm x 4 mm by means of nuts, bolts, chcek nuts and washers made of galvanised iron or steel earthing strip to be protected by galvanised iron pipe 40 mm bore (medium grade) up to ground level and there after with 40mm dia HDPE pipe up to test point. Earthing shall be include with providing funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) up to 90 cm all around earth plate further filled with 60 cm thick Tibba sand Earthing shall also be include for providing concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 Mtr etc all as shown on electrical plate No. 3 of MES Schedule Part-I complete to obtain less than 2 Ohm earth resistance value, complete all as specified. NOTE : (i) Cost of this items includes the scope of earth work, charcoal, salt, PCC, RCC pit cover of required size. (ii) Tibba sand shall be arranged by the contractor at his own and the cost thereof shall be deemed included in unit quoted rate of this item. (ii) Electrical Plate No. 3 refrred in the item above is mainly for earth chamber.
M&L for earthing complete with GI earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.4 Mtr deep below ground level with top edge of the plate not less than 1.50 Mtr below ground level. The earth plate to be connetced with earth lead of 4 mm dia galvanised iron or steel wire all as shown in para no 4 the earthing test point all as specified and directd.The GI earthing strip to be protected by galvanised iron pipe 40 mm bore (medium grade) up to ground level and there after with 40mm dia HDPE pipe up to test point. Earthing shall be include with providing funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) up to 90 cm all around earth plate further filled with 60 cm thick Tibba sand and 2nd layer with 30 cm of Magnesium sulphate powder (compact thickness ) , 3rd layer with tibba sand up to the ground level. Earthing shall also be include for providing concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 Mtr etc all as shown on electrical plate No. 3 of MES Schedule Part-I complete to obtain less than 2 Ohm earth resistance value, complete all as specified. NOTE : (i) Cost of this items includes the scope of earth work, charcoal, salt, PCC, RCC pit cover of required size. (ii) Tibba sand shall be arranged by the contractor at his own and the cost thereof shall be deemed included in unit quoted rate of this item. (ii) Electrical Plate No. 3 refrred in the item above is mainly for earth chamber.
Supply and fixing 32 x 6 mm copper strip as earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required .
S&F LT Panel Indoor type floor mounted free standing dust and vermin proof panel / DB with IP-42 protection, CPRI approved, frame fabricated out of 40mm x 40mm x 4mm angle iron, 3 mm thick CRCA sheet for entire outer panel with single door and locking arrangements & 1.6 mm for inner compartment with 40mmx4mm flat Iron, including Separate cubicle chamber with cable alley not less than 300mm width for installation/connecting switchgears with the main bus bar using aluminium bus link or copper conductor flexible wires suitable for switch rating and connecting outgoing terminals of the switchgear with terminal blocks of appropriate current rating using flexible copper wires duly terminated by cable lugs and thimbles, MS surfaces epoxy based powder coated, shade as approved over 2 coats of red oxide primer, surfaces pre-treated in seven tank process for de-greasing, de-rusting & Phosphated, panel having front and rear opening and provision for installation of separate cable alleys, busbar chamber and switchgear compartments, Provision in cable alleys for bottom cable entry for incoming & outgoing cables, affixing MV danger plate at suitable intervals / locations including erection, testing and commissioning including fixtures and fitments described in item No. 18.10 below complete all as specified and directed.
Supply and fixing DB TPN 4 way double door for incorporating MCBs IP 43, TPN 4 way with 200 amp rated busbar, 415 volts as per IS 8623, all as specified and directed.
Supply and fixing SPN DBs 8 way with double door for incorporating MCBs, IP 43, with 200 amp rated busbar, 240 volts as per IS 862 all as specified and directed.
Supply and fixing sheet metal enclosure for SPN DBs with double door for incorporating MCBs IP 43, 4 way with 200 amp rated busbar, 240 volts as per IS 8623, including single phase DBs, all as specified and directed.
Supply and fixing MCB four pole 63 Amps 16 KA conforming to IS 8623 415 volts 50 Hz including making necessary incoming and outgoing connection with suitable size of copper lugs etc. complete all as specified and directed.
Supply and fixing MCB four pole 32 Amps 16 KA conforming to IS 8623 415 volts 50 Hz including making necessary incoming and outgoing connection with suitable size of copper lugs etc. complete all as specified and directed.
Supply and fixing MCB SPN 32 Amps 10 KA 240 volts 50 Hz including making necessary incoming and outgoing connection with suitable size of lugs etc. complete all as specified and directed.
Supply and fixing MCB SPN 16 Amps 10 KA 240 volts 50 Hz including making necessary incoming and outgoing connection with suitable size of lugs etc. complete all as specified and directed.
Supply and fix MCB SP 6 to 20 Amps 10 KA 'C' curve 240 volts 50 Hz including making necessary incoming and outgoing connection with suitable size of lugs etc. complete all as specified and directed.
Supply, 'installation and testing of centrifugal monoblock pumpset 2 HP, 1.5 KW single phase 230 V 50 Hz head range up to 30 mtr complete all as specified and directed.
Supply and laying flexible PVC hose pipe 50 mm dia for using as suction pipe including all fixing arrangement all as specified.
Supply and laying flexible PVC hose pipe 40 mm dia for using as delivery pipe including all fixing arrangement all as specified.
M&L for wiring with PVC insulated retardant low smoke (FRLS) multi stranded copper conductor flexible cable of 4 sqmm 3 core including connected with 15 amps plug top all as specified and directed. .
S&F Junction box (Bus bar chamber box) of size 250 x 200x 105 mm made out palstic suitable for 415 Volt, 4 Way TPN aluminium bus bars of capacity 100 amps with 01 No. MCB, SP, 2.5 Amp, 240 volts, 10 KA for controlling the street light complete fixing arrangement to the pole with nut, bolts and washers including providing the electrical connection for incoming / outgoing cable through proper lugs/thimbles complete all as directed.
M&L wiring for alarm bell point for calling two call bell controlled / operated by one bell push switch with copper wiring complete with 03 runs (Phase, Neutral & Earthing colour code) of single core 2.5 sqmm fire retardant low smoke (FRLS) PVC insulated copper conductor cable multistranded and sheathed LT 1100 V grade drawn through with an including non metalic regid PVC medium conduit & conduit 20 mm dia ISI marked and all accessories on surface fixed on wall /floor etc all as specified. Note :- 4 run of 2.5 sq mm , 1 run of PVC conduit shall be measured as single unit length.
Supply and fix bell Switch piano type single pole 15 amp including pressed steel terminal boxes (for mounting switches) made out of MS sheet not less than 1.6 mm and 6 cm depth including painting with one coat of red oxide primer on internal and external surface covered with 3mm thick laminated plastic sheet ISI marked complete all as specified and directed.
Supply and fix bell switch modular type single pole 15 amp including GI modular box with cover including painting with one coat of red oxide primer on internal and external surface covered with 3mm thick laminated plastic sheet ISI marked complete all as specified and directed..
Supply and fix Ceiling rose surface Bakelite 65 x 50 mm three terminals complete all as specified and directed.
Supply, fixing and testing double gong alarm bell round working as single phase 230 V AC 50 Hz of size 15 cms (6") complete with fixing arrangement in wooden box completely all as specified and directed. Make Kheraj Model No DGB 15.
M&L boring of road crossing of size 100mm dia at suitable depth by trenchless technology using machinery complete without damaging the surface for passing pipes / cables etc. including removing excavated soil to a distance n exc 50m complete all as specified and as directed.
Supplying and laying 40 mm bore GI tubing light grade incl all accessories for water supply, laid under Plinth / Floors/ Paths Culverts or concealed in wall / floor or along with complete accessories such as bends / sockets / reducers / saddles incl necessary threading / drilling works all as specified and directed.
Supply and fixing Stop valves, cast copper alloy,screwed down,high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed
S&F rotational mouled polyyethiline water storage tanks 1000 litre capacity three layered (Cylidrecal vertical with clossed tap) hoisted and fixed in position all as specified and directed.
M&L cutting existing CI / GI pipe line 80mm dia and inserting GI Tee for taking new connection complete all as specified and directed. Note: The cost of Tee, nipple, Union is included in the unit quoted rate.
Supply and fixing single phase whole current energy meter with Acrylic box of accuracy class 1 as per IS standard 13779, 1 phase 2 wire, voltage rating 230 (P-N), current rating 5-30 A, 50 Hz complete all as specified and directed. Note : Rate quoted shall be deemed included for the following. (i) Cost of Copper wire through flexible conduit from DB to meter. (ii) Providing wooden board of suitable size with hylem sheet for mounting kWH meter. (iii) Writing quarter No. on Acrylic Box.
Supply and fixing Trivector meter three phase four wire with box Three Phase Whole Current energy meter of accuracy class 1 as per IS standard 13779, 3 phase 4 wire , voltage rating 3 x 230 Volt (P-N), current rating 10-60 A, 50 Hz complete all as specified and directed. Note :Rate quoted shall be deemed included for the following. (i) Cost of Copper wire through flexible conduit from DB to meter. (ii) Providing wooden board of suitable size with hylem sheet for mounting kWH meter. (iii)Writing quarter No. on Acrylic Box.
Supply and fixing Three Phase LTCT energy meter accuracy class 0.5 as per IS standard 14679, 3 phase 4 wire, voltage rating 3 x 240 Volt (P-N), current rating 5 Amp, 50 Hz. Note : Rate quoted shall also include the cost of the following. (i) Copper wire of size 6 Sqmm 4 core through flexible conduit from LT panel to meter. (ii) Providing wooden board of suitable size with hylem sheet for mounting kWH meter. (iii) Writing quarter No. on Acrylic Box. (iv) Current transformer for fixing in three Phase LTCT energy meter of rating 100/5 tape wound current transformer of class accuracy 1.0 with burden of 5 VA also included . (v) Disconnecting incoming cable and refixing cable in its original position with clour code sleeves
M & L for submain wiring complete with 03 runs of single core 6 Sqmm fire retardant low smoke PVC insulated copper conductor cable multistranded and sheathed LT 1100 V grade drawn through and including steel metallic conduit 25 mm dia ISI marked and accessories surface fixed on wall/ floor etc all as specified Note : 03 Runs of 1 meter cable & single run of conduit shall be considered as one unit for measurement purposes.
M & L for submain wiring complete with 05 runs of single core 6 Sqmm fire retardant low smoke PVC insulated copper conductor cable multistranded and sheathed LT 1100 V grade drawn through and including steel metallic conduit 32 mm dia ISI marked and accessories surface fixed on wall/ floor etc all as specified Note : 05 Runs of 1 meter cable and single run of conduit shall be considered as one unit for measurement purposes.
Supply and laying sub main wiring for alarm bell point controlled by one bell push switch with 03 runs (Phase, Neutral & Earthing colour code) of single core 1.5 sqmm FRLS copper conductor cable PVC insulated multistranded and sheathed LT 1100 V grade drawn through and including Non metallic rigid PVC conduit 20mm dia 2.00 mm thick ISI marked fixed on wall /floor etc with accessories duly connected with earth dolly complete all as specified and as directed. Note : (i) 3 run of cable shall be taken as one unit for measurement purposes. (ii) unit quoted rate shall also include the cost of flexible pvc conduit at end (LT panel side) and in between the rigid conduit where rigid conduit can not be provided as per site condition.
Excavating over areas, n.exc 1.5 m deep and getting out in hard/dense soil complete all as specified and directed.
All as per description of item No. 49.00 here in before but depth exc 1.50 m and n exc 3.00 m
M&L plain cement concrete 1:4:8 type D-2 using 40mm graded aggregate as in foundation, fillings, mass concrete complete all as specified and directed.
M&L brickwork with sub class 'B' bricks, straight or curved on plan n exc 6 m mean radius built in cement mortar 1:4 complete all as specified and directed.
M&L brickwork in half brick thick walls, with sub class 'B' bricks, old size, straight or curved on plan to any radius built in cement mortar 1:4 complete all as specified and directed.
M & L Brick work with sub-class 'B' bricks, honeycomb brick walling straight or curved on plan to any radius built in cement mortar 1:4 complete all as specified and directed.
S&F mild steel TMT bars 10mm dia and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
All as per description of item No. 56.00 here in before but 6 to 8mm dia bars
S&F mild steel TMT bars 5 to 10mm dia as in stirrups, spacers etc cut to length, bent to shape required, inlcuding cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
M&L Reinforced cement concrete 1:2:4 type B1 using 20mm graded aggregate as in beams, plinth beams bases for columns etc. complete all as specified and directed. Note:- Reinforcement and form work shall be measured and paid for separately.
M&L Reinforced cement concrete 1:2:4 type B1 using 20mm graded aggregate as in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed. Note:- Reinforcement and form work shall be measured and paid for separately.
M&L Reinforced cement concrete 1:2:4 type B1 using 20mm graded aggregate as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed. Note:- Reinforcement and form work shall be measured and paid for separately.
Formwork to edges of concrete flats, treads, treads breaks in floors, window cills, concrete railing, opening in concrete walls, floor and roofs n exc 20 cm wide complete all as specified and directed.
Formwork to rough finish to sides and soffits of floor or roof beams, plinth beams, haunching girder bressumers lintel cantilevers shelves incl support overhanges etc also splays between floors and beams etc complete all as specified and directed.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed.
Spreading and levelling earth filling in floors in layers and well ramming including watering as required complete all as specified and directed. Note : Earth obtained from excavation under respective item of this Schedule shall be re-used.
M&L Hard core of guage n.exc 63 mm, deposited, spread and levelled in layers n.exc 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L 75 mm thick PCC 1:3:6 type C-2 (using 40mm graded stone aggregate) in plinth protection, surface finished even and smooth without using extra cement complete all as specified and directed.
M&L 75 mm thick plain cement concrete 1:4:8 type D-2 using 40mm graded aggregate as in sub base, surface finished even and rough torecieve floor finishes complete all as specified and directed.
M&L chequred cement concrete tiles 25 cm x 25 cm x 22 mm thick with grey cement and pigment, set, jointed and pointed in neat cement slurry in floors, fixed over & including 20 mm thick screed bedding layer in CM 1:4. complete all as specified and directed.
M&L for 25mm thick plain cement concrete 1:2:4 type B0 using 12.5 mm graded aggregate as in floors finished even and rough to receive floor finishes complete all as specified and directed.
M&L non skid ceramic colour tiles 7 to 8mm thick (square or rectangular) area of each tile exceeding 0.06 Sqm but not exc 0.11 sqm in floors set and jointed in neat cement slurry and pointed in coloured cement to match the shade using coloured tiles over and including 15 mm thick Screed bed in CM 1:6 complete all as specified and directed.
M&L Glazed ceramic coloured tiles in vertical surfaces 300x200x7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match, over and including 10mm thick rendering/backing coat in CM 1:4 complete all as specified and directed.
M&L 15mm thick rendering in cement mortar 1:4 on brick or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
M&L Rendering 15mm thick in cement mortar 1:6 on brick work or concrete surfaces and finished even and smooth without using extra cement complete all as specified and directed.
M&L preperation of newly plastered surfaces of walls and applying two coats of Exterior emulsion paint of approved tint shade over a coat of approved primer on walls as in camouflage pattern complete all as specified and directed.
M & L for preperation newly plastered surfaces of walls and applying three coat of white wash complete all as specified and directed.
M&L for preperation newly plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed.
S&F PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube suppling fixing in opening etc. complete all aspecified and directed.
S&F solid PVC Panel Door shutter 30mm thick style consisting of Frame made out of M.S Tube for top & Bottom rails, MS Frame shall be covered with heat moulded, Plain colour PVC’C’ channel having a PVC Sheets strip of 20mm width struck inside with solvent cement for stiles and plain colour PVC sheets for Top rail, lock rail bottom rail on either side and as gap insert for top rail and bottom rail, paneling of plain colour 5mm thick PVC sheet fitted in the MS Frame, welded/ sealed to stiles and rail with suitable PVC sheet beading and jointed together with solvent cement all as per manufacture instruction all as specified.
S&F 100 MM Butt hinge, extruded aluminium alloy with galvanised mild steel hinge pin,anodised and fixed, type B-21 complete all as specified and directed.
S & F 200 mm length of aluminium anodised barrel tower bolts of extruded section and fixed complete all as specified and directed.
S & F 150 mm length of extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed.
S & F 300 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy complete all as specified and directed.
S&F steel ventilator with top hung shutter including hinges, steel peg stay complete all as specified and directed.
S&F 4 mm thick sheet figured glass, pin head type and glazing with wooden beads or oil putty in square not exc. 0.50 Sqm in each pane complete all as specified and directed.
M&L for two coats of Synthetic enamel paint over a coat of red oxide primer on new steel surfaces width or grith exc 10 cm including preperation of surfaces complete all as specified and directed.
S & F Vitreous China wash down water closet pan (pedestal pattern), white (excluding flushing cistern & flush pipe) including P or S trap, plastic water closet seat , black/white, closed pattern with flat bottom & cover and mild steel chromium plated or aluminized hinging device complete all as specified and directed.
S&F PVC valveless syphonic action type flushing cistern 10 lit capacity low level white with inlet, ball valve, float and handle including brackets and 32mm PVC flush pipe complete all as specified and directed.
S&F wash hand basin Vitreous china white flat back size 550x400mm excluding taps, waste, chain and plug and porcelain stopper but including brackets complete all as specified and directed.
S&F 32mm Waste fittings, brass, chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed complete all as specified and directed.
S&F PVC waste pipe of bore 32 mm to WHB /urinal complete all as specified and directed..
S & F Vitreous China Half stall urinal White complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60 mm long brass screws, fixing automatic flushing cistern with brackets and pointing around urinal back in cement, complete all as specified and directed.
S&F PTMT towel rail 600mm long fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 190 gms) complete all as specified and directed.
S&F Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered ‘Hot' or ‘Cold' with long screwed shanks and fly-nuts, screwed for iron pipe complete all as specified and directed..
S&F 15 mm dia Stop valves fancy type chromium plated screwed down, high pressure, with long shank and cup (concealed type)screwed both ends for iron pipe or for unions complete all as specified and directed.
S&F Stop valves/Aangle valves fancy type, chromium plated screwed down, high pressure, screwed both ends for iron pipe or for unions and fixed 15mm bore complete all as specified and directed.
S&F 125mm dia brass chromium plated shower rose with or without swivel joints including fixing to steel pipe or union fixed complete all as specified and directed.
Supply and fixed 15 mm bore Bib taps, brass chromium plated, fancy type, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
Supply and fix PVC connection 15mm size with PTMT nuts of length 600mm complete all as specified and directed.
S&F urinal spreader of PTMT any colour fixed on urinal pot connected to 15 mm dia pipe complete all as specified and directed.
S&F Rotational moulded polyethylene water storage tanks 500 litre capacity (cylindrical vertical with closed top), three layered, hoisted and fixed in position all as specified as directed.
S&F Tubes, ‘Medium grade’ galvanised, with all fittings and fixed to walls and ceilings or laid in floors of 15 mm bore complete all as specified and directed.
S&F Tubes, ‘Medium grade’ galvanised, with all fittings and fixed to walls and ceilings or laid in floors of 20 mm bore complete all as specified and directed.
S&F Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed 20 mm bore complete all as specified and directed.
S&F Ball valves high pressure of PTMT with epoxy coated aluminum rod and high density plastic ball screwed for iron pipe and fixed to 20mm bore pipe complete all as specified and directed.
S&F PVC (SWR) pipes 110mm bore single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed.
S&F PVC (SWR) pipes 110mm bore single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed.
S&F PVC (SWR) pipes 75mm bore single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed.
S&F PVC (SWR) floor trap 75mm dia outlet, with grating including jointing with solvent cement complete all as specified and directed.
S&F PVC (SWR) bend 110mm bore any radius complete all as specified and directed.
S&F PVC (SWR) bend 110mm bore any radius with access doors complete all as specified and directed.
S&F PVC (SWR) bend any radius 75mm bore
S&F PVC (SWR) bend any radius with access doors 75mm bore
S&F PVC (SWR) junction single, (Single T) equal or unequal with access door 75 mm bore
S&F PVC (SWR) vent cowl 110mm bore complete all as specified and directed.
M&L salt glazed stone wave gully traps square or rounded mouthed type 150 x 150 mm fixed in cement concrete complete all as specified and directed.
M& L salt glazed stone ware grade 'A' 100mm internal dia pipes laid in trenches and jointed socket end with packed spun yarn and cement mortar1:1 complete all as specified and directed.
M&L for Cement Concrete 1:3:6 type C-2 as concrete bed to slat glazes sotone ware drain pipes 100 mm dia including packing under, and haunching against the sides of pipes after they are laid and tested .
M&L PCC 1:2:4, type B-1 (using 20 mm graded stone aggregated) as in benching, coping, bed plates etc including necessary form work complete all as specified and directed..
Extra for forming fair finished channel and drain 30 cm inner girth in cement concrete using extra cement
M&L pre-cast cement concrete 1:2:4, type B1 (using 20 mm graded stone aggregate as in cover slabs for manholes incl necessary form work set in CM 1:4 complete all as specified and directed. (Reinforcement shall be measured & paid separately)
Supply and laying Broken brick coarse aggregate/bats exc. 63 mm size complete all as specified and directed. Note:- for payment purpose, 10% shall deducted on account of loose element.
BIDAWAT ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .