| 1 | 1₹6.1 LAccepted-AOC HOUSE NO 164 SHASTRI NAGAR NEAR JAL NIGAM BABINA CANTT DISTT JHANSI UP | BABINA CANTT | JHANSI | UTTAR PRADESH | 1 | Accepted-AOC lOWEST BIDDER | |
| 2 | 2₹6.5 L+₹6,311 (0.98%)Rejected-Finance SHIV NIWAS DHANDA P O TOTU DISTT SHIMLA HP 171011 | SHIMLA | SHIMLA | HIMACHAL PRADESH | 171011 | 2 | Rejected-Finance Not lowest bidder | |
| 3 | 3₹7.2 L+₹76,590 (11.9%)Rejected-Finance 1442 1 NANADANPURA BABINA CANTT TEHSIL DISTT JHANSI UP | BABINA | JHANSI | UP | 3 | Rejected-Finance Not lowest bidder | |
| 4 | 4₹8.2 L+₹1.8 L (28.6%)Rejected-Finance CIVIL LINE MATATILA ROAD TALBEHAT DISTT LALITPUR U P | TALBEHAT | LALITPUR | U P | 4 | Rejected-Finance Not lowest bidder | |
| 5 | 5₹8.3 L+₹1.9 L (29.3%)Rejected-Finance | 5 | Rejected-Finance Not lowest bidder |
Tender Value
Refer Docs
EMD Value
₹19,950
Closing Date
28 Jun 2023, 6:00 pmClosed
AGE I TALBEHAT
LAKEVIEW CAMP MIL STN TALBEHAT 284125
REPAIR/REPLACEMENT OF BUILDING ELECTRICAL FITTINGS AND FIXTURES, WIRING IN ZONE 14, 9C AND 10 AT MIL STN TALBEHAT
2023_MES_598734_1
AGE(I)/TBT/TOK-38/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AGE I TALBEHAT
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
AGE I TALBEHAT
₹19,950
Yes
1 Sept 2023
26 May 2023
30 Jun 2023
2 Jun 2023
28 Jun 2023
9 Jun 2023
Amount
Taking down carefully copper/Aluminium point wiring (light/fan/socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets etc., removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of wall, floors etc. complete all as directed.
Taking down carefully complete light fittings removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of wall, floors etc. complete all as directed.
Taking down Distribution Boards along with MCB's incl removing the same from site and making good to the disturbed surface complete. Note: All taken down MCBs should be deposited to MES store by the contractor without any extra charge.
Taking down existing sub main wiring of any type and description including removal of teak wood batten/pipe etc. complete.
M/L for point wiring concealed type with 1.5sq mm FRLS PVC insulated unsheathed single core multithreaded copper conductor cable 1100 volts grade incl 1.5 Sq mm PVC insulated unsheathed copper conductor cable as earth continuity conductor drown through in and incl FRLS PVC rigid conduit not less than 20 mm dia with its accessories pressed steel terminal box incl 3 mm thick ISI marked laminated sheet cover for fixing switches/socket/regulators etc. for the following: Note:- (i) On RCC ceiling/column, false ceiling, AC/Metallic Sheet ceiling wiring done on surface with conduit/PVC Casing caping and its accessories. (ii) Cutting of wall, floor, PCC work and white wash for making of good to disturbed surfaces shall be included in the rate quoted.
One light/fan/bell point controlled by one No piano type switch 5 Amps single pole one way
One socket outlet 5/3 pin 6 AMPS controlled by one switch on the same board.
One socket outlet 5/3 pin 6 AMPS controlled by one switch on independent board.
All as per item No 5 above but 3 pin socket out let 15/16 Amps on the independent Board all as specified with single core unsheathed PVC insulated cable multistranded copper conductor of size 4 sq mm for phase & neutral & 4 sq mm for earth continuity conductor.
S&F Switch Piano Flush button single pole one way 5/6 Amp.
S&F Switch Piano Flush button single pole one way 15/16 Amp.
S&F socket outlet 2 in 1, 5 pin & 2 pin, 5/6 Amp, 240 volt.
S&F socket outlet 2 in 1 , 5 pin & 2 pin, 5/6 Amp and 15/16 Amp, 240 volt.
S&F ceiling rose surface Bakelite 65mmx50mm 100watt three terminal.
S&F step type electronic fan regulator flush type one way on the existing phenolic laminated sheet.
S&F Lamp holder Batten Type PVC/Polycarbonate insulated body with metal ring and back plate for batten fitting with 9watt LED bulb.
S&F Lamp holder angular type PVC/Polycarbonate insulated body with metal ring and back plate for batten fitting including with 9watt LED bulb.
S&F Bell Ding Dong type, AC 230 Volts, Single pole.
S&F Bell Push, flush type, 5 Amp, AC-230 Volts, single pole.
M&L for sub main concealed wiring with two single core PVC insulated of size 6 sqmm FRLS unsheathed copper conductor 1100 volt grade multistranded and incl drawn through and including non metallic rigid PVC conduit and conduit accessories of 25 mm external dia and conduit FRLS accessories of ISI marks medium grade including 6.0 sqmm FRLS copper wire for earth continuity wire and connected of common earth dolly. Note:- (i)One run of conduit two run of 6 sq mm copper conductor & one run of 6.0 sq mm copper conductor is measured as one unit. (ii) On RCC ceiling/column, false ceiling, AC/Metallic Sheet ceiling wiring done on surface with conduit and its accessories. (iii) Cutting of wall, floor, PCC work and white wash for making of good to disturbed surfaces shall be included in the rate quoted.
M&L for sub main concealed wiring with two single core PVC insulated of size 4.0 sqmm FRLS unsheathed copper conductor 1100 volt grade multistranded and incl drawn through and including non metallic rigid PVC conduit and conduit accessories of 20 mm external dia and conduit FRLS accessories of ISI marks medium grade including 4.0 sqmm FRLS copper wire for earth continuity wire and connected of common earth dolly. Note:- (i)One run of conduit two run of 4 sq mm copper conductor & one run of 4.0 sq mm copper conductor is measured as one unit. (ii) On RCC ceiling/column, false ceiling, AC/Metallic Sheet ceiling wiring done on surface with conduit and its accessories. (iii) Cutting of wall, floor, PCC work and white wash for making of good to disturbed surfaces shall be included in the rate quoted.
S&F in replacement single pole and neutral enclosure with a two pin and earth socket complete with one single pole MCB of 20 Amp 240 volt.
S&F sheet metal enclosure double door for MCB DB single pole and neutral 8 way with 200 Amps 240 volts double door (Metallic) type.
S&F sheet metal enclosure double door for MCB DB single pole and neutral 4 way with 200 Amps, 240 volts double door (Metallic) type.
S&F MCB SP 5 to 63 Amps 240 volts 'C' series, 10 KA, 50 Hz, confirming to IS/IEC-60898-1. Make:- As approved Make of DB
S&F MCB SPN 32 to 40 Amps 240 volts 'C' series, 10 KA, 50 Hz, confirming to IS/IEC-60898-1. Make:- As approved Make of DB
Supply and fixing LED building security light fitting, 15/20 Watt made up of pressure die cast aluminium housing, inbuilt driver, top opening, IP 66, 230 Volt, complete connection with PVC insulated multi stranded copper flexible wire twin core of suitable size from nearest source complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing LED Panel 2'x2' with inbuilt driver 36 Watt suitable for ceiling/surface 230 Volt, complete connection with PVC insulated multi stranded copper flexible wire twin core of suitable size from nearest source complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing LED 4' tube light fitting 18/20 Watt 230 Volt, complete connection with PVC insulated multi stranded copper flexible wire twin core of suitable size from nearest source complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing LED 2' tube light fittings 9/10 Watt 230 Volt, complete connection with PVC insulated multi stranded copper flexible wire twin core of suitable size from nearest source complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing building security light bracket bend type complete with 2.0m long G.I. pipe 40mm dia light grade, with suitable clamp and nut bolts complete all as specified and directed by EIC.
Supply and laying or fixing in replacement GI tubes light grade 40 mm dia, on place of rusted GI pipe in support of Earth strip/ cables, on roof/pole/wall/laid in floor/in trenches.
Note :- Debris obtained from all items should be removed in low lying areas as directed by Engr-in-charge out of MOD Land. (Rates quoted for items are deemed to be included for this, where removal of debris in the items is not considered.)
M/s Dinesh Kumar
M/S SHIVA TRADERS
HARNAM SINGH ANIL SINGH
M/s Pooja Electricals
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .