| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.3 LAccepted-AOC | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹32 L+₹72,271 (2.31%)Rejected-AOC B1 DAYA NAGAR SHAMSHABAD ROAD RAJPUR CHUNGI AGRA UTTAR PRADESH 282001 | AGRA | UTTAR PRADESH | 282001 | L2 | Rejected-AOC Rejected due to not being L1 | |
| 3 | L3₹35.7 L+₹4.4 L (14.1%)Rejected-AOC 21 JHAMRI 151 JHAMRI JHAMRI ROHTAK HARYANA 124142 UDYAM HR 07 0030314 | JHAJJAR | HARYANA | 124142 | L3 | Rejected-AOC Rejected due to not being L1 | |
| 4 | L4₹36.3 L+₹5.0 L (16.0%)Rejected-AOC | L4 | Rejected-AOC Rejected due to not being L1 | |
| 5 | L5₹37.5 L+₹6.2 L (19.8%)Rejected-AOC | L5 | Rejected-AOC Rejected due to not being L1 |
Tender Value
Refer Docs
EMD Value
₹89,800
Closing Date
29 Jun 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE NORTH UDHAMPUR
GE NORTH UDHAMPUR
GE U(N) 30 2023 24 REPAIR MAINT CLEANING OF SEWAGE LINE SEPTIC TANK AND CONNECTED ITEMS FOR OTM MD ACCN AT CH AND ADJOINING AREA UNDER AGE B R I OF GE (N) UDHAMPUR
2023_MES_600949_1
GE/U(N)-30 2023-24
Open Tender
Civil Works
Item Rate
330 days
GE NORTH UDHAMPUR
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE NORTH UDHAMPUR
₹89,800
Yes
4 Aug 2023
3 Jun 2023
1 Jul 2023
3 Jun 2023
29 Jun 2023
16 Jun 2023
Amount
M&L for systematically Cleaning of blockage of WC Indian, Orrisa pattern or European type and bathroom/ kitchen including cleaning of Nahani traps/gully traps/floor by removing of all the mud/sludge and getting out in including cleaning of SGSW or CI pipe upto Ist manhole and depositng the sludge in a pit of suitable size at a distance not exceeding 50 metres from the gully trap and covering the same with the soil obtained from excavation of of pit including all excavations and earth work complete all as specified and as directed by Engineer-in-charge. Note :- (i) The contractor or his authorised representative shall collect the complaints of all blockage from complaint cell/Engr-in-charge daily and all complaints will be rectified by the contractor with in same day and returne the complaint slip after completion of complaint and get receipt from concerned JE/Engr-in-charge. If he fails to complete the work with in same day then recovery will be made @ Rs 50.00 per complaint per day. (ii) Work shall be done in foul conditions , necessary precautionary measures/equipments to be adopted by the contractor .(iii) Any damage caused during cleaning shall be made good by the contractor to the entire satisfaction of Engr-in-Charge without any extra cost to Govt.
M&L for Systematically cleaning of the sewage lines including gully traps by passing ropes, Knots, bamboo/wire/kandi rotary cleaner etc for any type of dia of sewage pipe, complete all as specified and as directed by Engr-in-Charge.
M&L for cleaning and desludging of manholes of any size, shape and any depth including pumping out liquid waste if any, removing all solid waste materials such as stones, bricks, pipes, plastic muds etc, pluggings/ diverting of flow if required and removing the debries outside MOD land as authorized by muncipial cooperation with proper goverment reciept including all precautionary and safety measures all as directed.
M&L for cleaning and desludging & de-watering of existing septic tanks for 100 users and opening covers, and including inlet and outlet chambers and soakage well, taking out sludge & sewage water in any form alongwith all other foreign materials by mechanical equipment or by way of other suitable means , and removing waste material/sludge etc out side MOD land as authorized by muncipial cooperation with proper goverment reciept (Qty of desludging taken out n. exc 12.0 Cum and Dewatering n exc 12.0 Cum from Each Septic tank) complete all as specified and directed by Engineer-in-charge. Note :- (i) Work shall be done in foul conditions , necessary precautionary measures/equipments to be adopted by the contractor. (ii) The solid or semi solid sludge shall be remove out side MOD land as authorized by muncipial cooperation with proper goverment reciept (iii) Rates quoted by the contractor shall be deemed to have considered all such contingencies including removal and refixing man hole covers. (iv) Any damage caused during cleaning shall be made good by the contractor to the entire satisfaction of Engr-in-Charge without any extra cost to Govt.
Same as item No. 4 above but 50 users capacity ( desludging n exc 6.0 cum and dewatering n exc 6 cum from each septic tank) complete all as specified and as directed by Engineer-in-charge.
Same as item No. 4 above but 25 users capacity ( desludging n exc 4.0 cum and dewatering n exc 4 cum from each septic tank) complete all as specified and as directed by Engineer-in-charge.
M&L for excavation in trenches in any type of soil not exceeding 1.50m wide and not exceeding 1.50m in depth for foundation etc or for shafts, manholes, pier holes etc n.exc 10 sqm on plan and not exc 1.50m in depth and getting out in any type of soil, complete all as specified and directed by the Engr-in-charge.
All as above srl item No. 08 but exc 1.5m Not exc3.00m all as specified and directed by the Engr-in-charge.
M&L for HDPE DWC (Double wall corrugated) pipes confirming to IS-16098, of 170mm internal dia, presure rating SN-8 fixed with rubber seal and copler required with and including suitable bends 90/60/45 degree etc single Y junction, complete as required fixed as per manufacturer instruction laid in trenches for sewage lines all complete all as specified and as directed by Engineer-in-charge. Note :- Rates included for taking out old sewage pipe any type and dia, bends any size and type, Y Jn coupler /adaptor etc required and net total length of pipe with fittings shall be measured for payment purpose.(ii) Contractor shall submit the test certificate and purchase vouchers before applying for payement .
M&L for HDPE DWC (Double wall corrugated) pipes confirming to IS-16098, of 150mm internal dia, presure rating SN-8 fixed with rubber seal and copler required with and including suitable bends 90/60/45 degree etc single Y junction, complete as required fixed as per manufacturer instruction laid in trenches for sewage lines complete all as specified and as directed by Engineer-in-charge. Note :- Rates included for taking out old sewage pipe any type and dia, Y Jn coupler /adaptor etc required and net total length of pipe with fittings shall be measured for payment purpose. (ii) Contractor shall submit the test certificate and purchase vouchers before applying for payement .
M&L for 150 mm Reinforced concrete pipes, class NP2, laid and jointed complete with collars complete all as specified and as directed by Engineer-in-charge.
M&L for 200 mm dia Reinforced concrete pipes class NP2, laid and jointed completed with collar complete all as specified and as directed by Engineer-in-charge.
M&L for 300 mm dia Reinforced concrete pipes class NP2, laid and jointed completed with collar complete all as specified and as directed by Engineer-in-charge.
M&L for cement concrete in 1:4:8 type D-2 (using 40 mm graded stone aggregate) in foundation bed for laying of sewage lines or mass concrete, complete all as specified and as directed by Engr-in-Charge.
M&L for Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and directed by the Engr-in-charge.
M&L for Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed by the Engr-in-charge.
M&L for Demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortar in any dia up to 300mm complete all as specified and as directed by Engineer-in-charge
M&L for Dismantling/ taking out of cast iron or reinforced concrete drain pipes, jointed in cement mortar and taking out of trenches/wall upto & incl of internal dia of pipe 100/75 mm, all as specified and directed by the Engr-in-charge.
S&F 100 mm dia Cast iron Sand soil pipes, waste and vent pipes in any length with or without ears with cement joints, laid in trenches or in floors all specified and directed by the Engr-in-charge.
S&F 100 mm dia Cast iron Sand pipes, waste and vent pipes, in any length with or without ears with cement joints, fixed to wall with MS clamps all specified and directed by the Engr-in-charge.
All as per Sl. item No 20. above but refixing only (except pipe) with stack clamp, etc, complete all as specified and as directed by Engr-in-Charge.
S&F 75 mm dia iron sand cast pipes, waste and vent pipes, in any length with or without ears with cement joints, fixed to wall with MS clamps all specified and directed by the Engr-in-charge.
All as per Sl. item No 21.above but refixing only (except pipe) with stack clamp, etc, complete all as specified and as directed by Engr-in-Charge.
S&F in repairs CI sand cast 100mm bore bends/reducer/Tee (any radius) with access door diminishing pieces or tapers (larger bore measured) all as specified all specified and directed by the Engr-in-charge.
All as per srl item No. 24 above but 75mm bore, complete all as specified and as directed by Engr-in-Charge.
S&F in repairs CI sand cast 100mm bore Branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches all as specified all specified and directed by the Engr-in-charge.
All as per srl item No. 26 above but 75mm bore, complete all as specified and as directed by Engr-in-Charge.
S&F 100 mm bore CI vent cowl including taking down old CI vent cowl of any type complete all as specified and as directed by Engineer-in-charge
Ditto all as Item No 28 above but 75mm.
M&L for Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends swan necks, etc, including cleaning or refixing or removal to store (measured overall as fixed along the centre line over fitting and accessories) complete all as specified and as directed by Engineer-in-charge
S&F 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls with MS clamps, all as specified and directed by the Engr-in-charge.
S&F110 mm bore PVC (SWR) bends with access door any radius, all as specified and directed by the Engr-in-charge.
S&F 75 mm bore PVC(SWR) floor trap with stainless steel grating including jointing to waste pipe fixed in cement with solvent cement, including taking down old PVC or CI floor trap of any type complete all as specified and as directed by Engineer-in-charge.
S&F PVC (SWR) pipes of bore 75mm single socketed in any length with rubber ring joints laid in floors complete all as specified and directed by the Engr-in-charge.
M&L for taking down cement plaster, any description on brick or stone or cement concrete walls including raking out joints, hacking for key, scrubbing down with water complete, all as specified and directed by the Engr-in-charge.
M&L for 15 mm thick cement plaster on the fair face of brick or concrete surface in cement mortar 1:4 finished even and smooth without using extra cement,all as specified and directed by the Engr-in-charge.
M&L for Demolition of brick work or stone masonry built in cement mortar including all quoins arches, pillar etc but excluding ashlar facing , dressed stone work and precast concrete articles, complete all as specified and as directed by Engineer-in-charge.
M&L for Brick work with sub class 'B' bricks, straight or curved on plan exceeding 6 metre mean radius, using old size bricks, built in cement mortar 1:6 , complete all as specified and as directed by Engineer-in-charge.
All as per item No. 38 herein before, but except bricks. Note-Old bricks obtained against dismantling shall be used.
M&L for Walling of random rubble, uncursed, well bonded, bedded and solidly hearted, built in cement mortar 1:4 complete all as specified and as directed by the Engr-in-charge.
All as per Srl item 40 above here n before but except stone.
M&L for Flush pointing to random rubble, uncoursed on brought upto course on masonry or concrete block walling in cement mortar 1:4 complete all as specified and as directed by the Engr-in-charge.
M&L for 50mm thick, PCC 1:3:6 type C1 (using 20mm graded stone aggregate) in plinth protection finished even & smooth with out using extra cement including making joints 10mm wide and 30mm deep at spacing not more than 2.5m and at corners as mandatory and filled with sealing compound grade A complete all as specified and as directed by Engineer-in-charge.
M&L for Providing cement concrete 1:2:4 type B-1 ( Using 20 mm graded crushed stone aggregate ) as in coping, etc including necessary formwork as required complete all as specified and as directed by the Engr-in-charge.
M&L for Cement concrete 1:2:4 type B-0 ( Using 12.5 mm graded crushed stone aggregate ) as in surface channel or drain including necessary form work etc, complete all as specified and as directed by the Engr-in-charge.
M&L for pre-cast RCC 1 : 2 : 4, type B-1 (using 20 mm graded stone aggregate) in cover slabs for man holes with plain faces finished fair and smooth etc, set in CM I : 6 and including necessary formwork if required incl. demolition of old slabs complete all as specified and directed.
M&L for RCC Nominal Mix 20mm gradded aggregate (1:2:4) Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves complete all as specified and as directed by the Engr-in-charge.
M&L for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and as directed by the Engr-in-charge.
M&L for dismantling/ demolition of wrought iron/ mild steel / steel works of any description and in any position , complete all as specified and as directed by Engr-in-charge.
M&L for Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and as directed by Engineer-in-charge.
M&L for MS TMT bars 8 mm dia and over as in reinforcement for concrete, cut to length, bent to shape required, including cranking, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia all as specified complete all as specified and as directed by Engineer-in-charge.
M&L for Demolition of cement concrete (un reinforced) in ground floor and paving n/exe 15 cm thickness (below or above ground level) complete all as specified and as directed.
M&L for Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for complete all as specified and as directed by Engineer-in-charge.
S & F in repair Wash down water closet (Pedestal pattern), complete with Pedestal pan and trap, including connection to drain (or outgoing pipe) and to flushing pipe, antisyphonage pipe, etc.including PVC Seat and cover for pedestal pan complete all as specified and as directed by Engineer-in-charge.
S&F in repair PVC low level flushing cistern of capacity 10 ltr. white with inlet, ball valve, float and handle including breckets, flush pipe of polyethylene of low or high density or PVC 32mm dia and connection to pipes complete all as specified and as directed by Engineer-in-charge.
S&F in replacement wash basins, vitreous china(flat back or angle back type) size 550 X 400mm,with pedestal height 800mm including cutting for and pinning in ends of brackets or erecting stand including CP waste coupling 32mm and pvc waste pipe 32mm borecomplete all as specified and directed by Engineer in charge
S & F in repair for Vitreous China Urinal, half stall type, white (excluding flushing cistern, flush pipe) but including waste coupling, Urinal spreader with PVC connections and waste pipe, complete all as specified and as directed by Engineer-in-charge.
M&L for Chequered vitrified tiles 300mm x 300mm x 25mm thick coloured with grey cement & admixtures laid over 15mm thick cement mortar 1:4 set, jointed and pointed in neat cement slurry in floors, complete all as specified and as directed by Engineer-in-charge.
M&L for Machine pressed rubber moulded manufactured/compacted by vibrating table method pre-cast concrete interlocking paver block Laquor finish any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 grade with grey cement and pigment and joints filled with sand complete all as specified and as directed by Engineer-in-charge.
M&L for Refixing of interlocking tiles of any thickness laid dry in position over sand cushioning including dismantling of existing tiles, complete all as specified and as directed.
M & L for Sand filling under floors or in foundations including watering and consolidation, complete all as specified and as directed.
M&L for 75mm thick PCC 1:4:8 type D1 (using 20mm graded stone aggregate) as in Sub base complete all as specified and as directed by Engineer-in-charge.
M&L for Providing and laying water proofing treatment to sunken portion of WCs, bathrooms, etc by applying first layer of slurry of cement @ 0.488kg/Sqm mixed with acrylic based polymer modified cementitious composite compound @ 0.253kg/sqm this layer allowed to air cure for 4 hrs then applying slurry of cement @ 0.242 kg/sqm mixed with acrylic based polymer modified cementitious composite compound @0.126kg/sqm and allowed to aircure for 4 hrs and joints seal with sealing compound as approved by GE. Note: (i) Before laying of lime concrete joints of trap/WC/Soil pipes shall be properly sealed with sealing compound of Roofex/Forre/FOSROC and provn of P or S trap & Nahani /Floor traps with long arm.
M&L for Rendering 15mm thick on fair faces of brick work or concrete surfaces in Cement mortot as in CM 1:3 finishing even & smooth w/o using extra cement, complete all as specified and as directed.
M&L for Lean concrete using 40mm graded stone aggregate as in 1:5:10 as in sunken portion treatment, complete all as specified and as directed.
M&L for Vitreous china squalting pan, orissa pattern size 580 x 440 mm white with integral foot rests, P or S trap long body with integral foot rest and fixed with cement concrete bedding complete all as per specified. (Fixed in Repair).
M&L for Non skid ceramic coloured tiles 7 to 8 mm thick (sqare/ rectanglear) area of each tile exc 0.11sqm but n exc 0.18 sqm in floor etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match incl 10mm thick screed bed in Cement mortar (1:4) complete all as specified and as directed by Engineer-in-charge.
M&L for Glazed ceramic coloured digital tiles in vertical surfaces of wall of size 450mm x 300mm x 7mm thick/ 600mm x 300mm x 7mm thick as approved pattern approved by GE, set and jointed in neat cement slurry and pointed in white or coloured cement to match over 10 mm thick rendering in Cement mortar 1:4 as in skirting, dado, etc, complete all as specified and as directed by Engineer-in-charge.
M&L for 25mm thick PCC 1:2:4 type B0 (using 12.5mm graded stone aggregate) as in floor base of tiles complete all as specified and as directed by Engineer-in-charge.
M&L for Dismantling of floor hearth or wall tiling incl CM, bedding (but not backing) and rubbish off the premises complete all as specified and as directed by Engineer-in-charge.
M&L for Prepration of new plaster surfaces of wall and applying two coats of cement based paint over a coat of alkali resistant cement base primer on wall surfaces complete all as specified and as directed by Engineer-in-charge.
S&F in repair PVC flexible urinal pipe 50mm dia 900 long complete all as specified and as directed by Engineer-in-charge.
S&F in repair PVC flexible waste pipe for wash basin /sink complete all as specified and as directed by Engineer-in-charge.
MAHAJAN TRADING CO
KUMAR CONSTRUCTION CO
sohtra and co
M/s AKHIL SHARMA
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .