Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Ref. No.
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Qualified | Qualified Qualified |
| 2 | Qualified PLOT NO GA 62 GAYATRI VIHAR PATIA BHUBANESWAR ODISHA 751024 | BHUBANESWAR | KHORDHA | ODISHA | 751024 | Qualified Qualified |
| 3 | Qualified 1 CROOKED LANE 2ND FLOOR ROOM NO 205 KOLKATA 700 069 WEST BENGAL | KOLKATA | KOLKATA | WEST BENGAL | 700069 | Qualified Qualified |
| 4 | Qualified PLOT NO 178 A MLA COLONY ROAD NO 12 BANJARA HILLS HYDERABAD 500 034 | HYDERABAD | TELANGANA | 500034 | Qualified Qualified |
| 5 | Qualified | Qualified Qualified |
Tender Value
₹35.5 Cr
Closing Date
13 May 2024, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Yogesh Kushwaha & Dy. Manager
PLOT NO.4, UNIT-41, NILADRI VIHAR, CHANDRASHEKHARPUR, BHUBANESWAR-751021
Construction of a Control Centre Building for OPTCL STAMS (State Transmission Asset Management System) Project by POWERGRID under Consultancy Services to OPTCL
ODP/BB/CnM-3575/OT-24/RFx No. 5002003243/23-24
Open
Civil Works - Buildings
Works
Bhubaneswar
₹25,000
13 May 2024
23 Jan 2024
13 May 2024
23 Jan 2024
3 May 2024
23 Jan 2024
Name of Package : Construction of a Control Centre Building for OPTCL STAMS (State Transmission Asset Management System) Project by POWERGRID under Consultancy Services to OPTCL
Tender Enquiry No. : ODP/BB/C&M-3575/OT-24/RFx No. 5002003243/23-24
Completion Period 08 (Eight) Months
: Attachments : General guidelines for filling up the Attachments : Civil Works Package - :
Construction of a Control Centre Building for OPTCL STAMS (State Transmission Asset Management System) Project by POWERGRID under Consultancy Services to OPTCL
Tender Enquiry No. : ODP/BB/C&M-3575/OT-24/RFx No. 5002003243/23-24
1 Fill up only green shaded cells in the relevent attachments.
2 Attachments Bid Form for 1st Envelope, 3(QR), Attach QR, 4, 5, 5 (A), 6, 7, 8, 9, 10, 11, 11-IP, 12, and 13 are included here.
3 Attachment 1 Bid Security : To be submitted as perproforma provided in the bidding document.
4 Attachment 2 Power of Attorney : No specific format is provided by POWERGRID. Bidder may use their own format.
5 Attachment 11 Integrity Pact : To be submitted as per ITB Clause No. 9.3(m) and as per remarks in the Attach 11-IP.
6 Attachment 14: Scanned copies in respect of Information for E – payment, PF details and declaration for Micro & Small Enterprise etc. as applicable shall be uploaded,)
Note : Enable the Active X Control & Macros. Also ensure to keep option of "Trust acess to VBA project object Model" cheched [√]. Ensure that you work on MS Excel 2007 or higher version.
Construction of a Control Centre Building for OPTCL STAMS (State Transmission Asset Management System) Project by POWERGRID under Consultancy Services to OPTCL
Tender Enquiry No. : ODP/BB/C&M-3575/OT-24/RFx No. 5002003243/23-24 Sole Bidder 1
JV (Joint Venture) 2 or More
Enter following details of the bidder
Specify type of Bidder [Select from drop down menu] JV (Joint Venture) 2 or More
Total Nos. of Partners in the JV [excluding the Lead Partner] 2 or More
Address of Bidder
Whether the bidder is an MSE (Micro & Small Enterprise)
E-mail Id of Bid Signatory
Mobile no. Bid Signatory
Tel. no. of Bid Signatory
Name of other Partner - 2 (More, if any)
Address of other Partner - 2 (More, if any)
Any Tower Parts Manufacturer proposed other than the bidder [Yes / No]
Proposed Tower Parts Manufacturer other than the bidder, if any [Maximum two nos.]
Tender Enquiry No. : ODP/BB/C&M-3575/OT-24/RFx No. 5002003243/23-24 Attachment-3(JV) JV (Joint Venture) 0
Construction of a Control Centre Building for OPTCL STAMS (State Transmission Asset Management System) Project by POWERGRID under Consultancy Services to OPTCL
(Joint Venture Agreement and Power of Attorney for Joint Venture*)
Bidder’s Name and Address (Bidder) : To :
Name : POWER GRID CORPORATION OF INDIA LIMITED,
Address : ODISHA PROJECTS
PLOT NO.-4, UNIT-41, NILADRI VIHAR
CHANDRASHEKHARPUR, BHUBANESWAR-751021
Name(s) and Addresse(s) of other partner(s)
Other Partner-1 Other Partner-2
The Joint Venture Agreement (as per the proforma attached at Annexure -I, Special Conditions of Contract, Vol.-I of the Bidding Documents) and Power of Attorney for Joint Venture (as per the proforma attached at Annexure -II, Special Conditions of Contract, Vol.-I of the Bidding Documents) are enclosed herewith.
Date : Printed Name : 0
Place : Designation : 08 (Eight)
Tender Enquiry No. : ODP/BB/C&M-3575/OT-24/RFx No. 5002003243/23-24 Attachment- 3 (QR)
Construction of a Control Centre Building for OPTCL STAMS (State Transmission Asset Management System) Project by POWERGRID under Consultancy Services to OPTCL
(Qualifying Requirement Data)
Bidder’s Name and Address (Bidder) : To :
Name: POWER GRID CORPORATION OF INDIA LIMITED,
Address: ODISHA PROJECTS
PLOT NO.-4, UNIT-41, NILADRI VIHAR
CHANDRASHEKHARPUR, BHUBANESWAR-751021
In support of the Qualification Requirements (QR) for bidders, stipulated in Annexure-A (BDS) of the Section - III (BDS), Volume-I & additional information required as per ITB clause 9.3(c) of the Bidding Documents, we furnish herewith our QR data/details/documents etc., alongwith other information, as follows (The QR stipulations have been reproduced in italics for ready reference, however, in case of any discrepancy the QR as given in BDS shall prevail).
We are furnishing the following details/document in support of Qualifying requirement for the subject package.
A Attached copies of original documents of the Bidder in PDF format.
a) The constitution or legal status;
b) The principal place of business;
c) The place of incorporation (for bidders who are corporations); or the place of registration and the nationality of the Owners (for applicants who are partnerships or individually-owned firms).
1.0 GENERAL INFORMATION
Bidder is required to provide general information as per the following format.
[Where the Bidder proposes to use named subcontractor(s) for critical components of the works or for work contents in excess of ten (10) percent of the bid price, the following information should also be supplied for the subcontractor(s)].
S No. Particulars
1 Name of the Firm
2 Head Office/ Registered Office Address
5 Contact Person
6 Place of Incorporation/ Registration
7 Year of Incorporation/ Registration
2.0 TECHNICAL REQUIREMENTS
2.1 Technical Experience
2.1.1 {Reference para I, Part -A of Annexure-A (BDS)}
2.1.2 Using the following format, each Bidder (individual firms ) is requested to list the contracts of a nature similar to the proposed contract for which the Bidder wishes to qualify, undertaken during the last seven (7) years. The information is to be summarised for each such contract separately.
[In support of above bidder should required to provide documentary evidence like copies of Final time extension/Performance Certificate/TOC/Completion Certificate , along with corresponding work/purchase order etc. Such documents need to be uploaded as attachment.]
Bidder’s Name :
a Name of Contract Undertaken
b Contract Reference No. & Date of Award
c Name and Address of the Employer/Utility for whom the Contract was executed by the firm
d Scope of work executed under the above contract (as in Sl No (i) of 2.1.1) (Tick only whichever is/are applicable)
e Capacity in which the Contract was undertaken (Select One from Drop Down)
f If Contract was taken as JV partner scope of partner
g Date of Completion of Contract
h Details of documents furnished in the Bid, in support of the aforesaid data/ details/ information
3.0 Financial requirement
3.1 {Reference para II, Part -A of Annexure-A (BDS)}
b) (b) Bidder shall have liquid assets (L.A.) or/and evidence of access to or availability of credit facilities of not less than INR 2.27 Crores. The Letter/ certificate regarding availability of credit facilities (along with utilization) from the bank should have been issued not more than three months prior to the date of NIT publication.
3.2 In support of its ‘Financial Position’, in line with the above, the Bidder must provide the relevant information, alongwith documentary evidence, in the following formats A & B:
Name of the Bidder
A Average Annual Turnover details: Average annual turnover (in INR)
Sl. No. Financial year
Do you have audited results for FY 2013-14
Average Annual Turnover for best Three Years is
B Liquid Assets
Details of evidence of having Liquid assets (LA)
Details of evidence of access to or availability of credit facilities
6.0 LITIGATION HISTORY: Details of litigation History resulting from the contracts completed or under execution by the bidder over last five years.
Select whichever is applicable (If yes give the details as per below) : NO
Year Name of Client, cause of Litigation/Arbitration and matter of dispute Details of Contract & Date Judgment for or against the bidder Disputed Amount
We do not have any litigation History resulting from the contracts completed or under execution by us over last five years
6.0 Technical Credentials: List of work regarding past experience indicating the execution of similar work successfully, schedule time of completion and actual time of completion, the present status of projects in hand along with presently envisaged completion dates, qualification and experience of key personnel proposed for carrying out the subject work. List of available T & P and Manpower available with the bidder is also to be enclosed
6.1 Works in Hand
Details of Contract Value of Outstanding projects Tentative Completed date
6.2 List of Tools, Equipments & Plants
Sl. No. Name of Machine Nos
6.3 Qualification & Experience of key personal:
Sl. No. Designation Qualification Experience in Years
Date: Printed Name :
Place:. Designation :
Tender Enquiry No. : ODP/BB/C&M-3575/OT-24/RFx No. 5002003243/23-24 Attachment- 4
Construction of a Control Centre Building for OPTCL STAMS (State Transmission Asset Management System) Project by POWERGRID under Consultancy Services to OPTCL
(COMMERCIAL DEVIATIONS)
Bidder’s Name and Address (Bidder) : To :
Name : POWER GRID CORPORATION OF INDIA LIMITED,
Address : ODISHA PROJECTS
PLOT NO.-4, UNIT-41, NILADRI VIHAR
CHANDRASHEKHARPUR, BHUBANESWAR-751021
Sub. : Commercial Deviations for Package.
The following are the Commercial deviations and variations from and exceptions to the specifications and documents for the subject package. These deviations and variations are exhaustive. Except for these deviations, the entire work shall be performed as per your specifications and documents.
NOTE : Any deviation taken by the bidder without any withdrawal price shall not be considered as deviation and the bidder has to execute the work as per terms of bid documents in case of award.
Sl. No. Volume/ Clause Ref/ Page No. As Specified in the specification Commercial Deviation & Variations to the specifications Withdrawal Price (in INR)
Date: Printed Name :
Place:. Designation :
Tender Enquiry No. : ODP/BB/C&M-3575/OT-24/RFx No. 5002003243/23-24
[Commercial Deviations Schedule]
Sl. No. Vol./ Clause Ref/ Page No. As Specified in the specification Commercial Deviation & Variations/Exceptions
Date: Printed Name :
Place:. Designation :
Tender Enquiry No. : ODP/BB/C&M-3575/OT-24/RFx No. 5002003243/23-24 Attachment- 5
Construction of a Control Centre Building for OPTCL STAMS (State Transmission Asset Management System) Project by POWERGRID under Consultancy Services to OPTCL
(TECHNICAL DEVIATIONS)
Bidder’s Name and Address (Bidder) : To :
Name : POWER GRID CORPORATION OF INDIA LIMITED,
Address : ODISHA PROJECTS
PLOT NO.-4, UNIT-41, NILADRI VIHAR
CHANDRASHEKHARPUR, BHUBANESWAR-751021
Sub. : Technical Deviations for Package.
The following are the Technical deviations and variations from and exceptions to the specifications and documents for the subject package. These deviations and variations are exhaustive. Except for these deviations, the entire work shall be performed as per your specifications and documents.
NOTE : Any deviation taken by the bidder without any withdrawal price shall not be considered as deviation and the bidder has to execute the work as per terms of bid documents in case of award.
Sl. No. Volume/ Clause Ref/ Page No. As Specified in the specification Technical Deviation & Variations to the specifications Withdrawal Price (in INR)
Date: Printed Name :
Place:. Designation :
Tender Enquiry No. : ODP/BB/C&M-3575/OT-24/RFx No. 5002003243/23-24
[Commercial Deviations Schedule]
Sl. No. Vol./ Clause Ref/ Page No. As Specified in the specification Technical Deviation & Variations to the specifications
Date: Printed Name :
Place:. Designation :
Tender Enquiry No. : ODP/BB/C&M-3575/OT-24/RFx No. 5002003243/23-24 Attachment- 5(A)
Construction of a Control Centre Building for OPTCL STAMS (State Transmission Asset Management System) Project by POWERGRID under Consultancy Services to OPTCL
[ Deviations on important/critical conditions along with their withdrawal price]
Bidder’s Name and Address (Bidder) : To :
Name : 0 POWER GRID CORPORATION OF INDIA LIMITED,
Address : ODISHA PROJECTS
PLOT NO.-4, UNIT-41, NILADRI VIHAR
CHANDRASHEKHARPUR, BHUBANESWAR-751021
The following are the deviations/variations/exceptions to the provisions of important/ critical conditions stipulated in Clause 2.5, Special conditions of Contract (SCC), Section - IV, Volume-I. We undertake to execute the contract in line with the provisions of Bidding Documents in respect of above said clauses in case POWERGRID agrees to pay- us the withdrawal price indicated below against each such deviations/ variations/ exceptions.
Sl. No. Volume of Bidding document Section Clause No./ Page No. Statement of Deviations/ Variations/ Exceptions Withdrawal Price (in INR)
2 NO DEVIATION IN THE PROVISION OF IMPORTANT/CRTICAL CONDITION OF THE TENDER IS ALLOWED
Date: Printed Name :
Place:. Designation :
Tender Enquiry No. : ODP/BB/C&M-3575/OT-24/RFx No. 5002003243/23-24
[ Deviations on important/critical conditions along with their withdrawal price]
Sl. No. Vol./ Section Clause No./ Page No. Statement of Deviations/Variations/Exceptions Withdrawal Price (in INR)
Date: Printed Name :
Place:. Designation :
Tender Enquiry No. : ODP/BB/C&M-3575/OT-24/RFx No. 5002003243/23-24 Attachment- 6
Construction of a Control Centre Building for OPTCL STAMS (State Transmission Asset Management System) Project by POWERGRID under Consultancy Services to OPTCL
(Additional Information)
Bidder’s Name and Address (Bidder) : To :
Name : POWER GRID CORPORATION OF INDIA LIMITED,
Address : ODISHA PROJECTS
PLOT NO.-4, UNIT-41, NILADRI VIHAR
CHANDRASHEKHARPUR, BHUBANESWAR-751021
We have enclosed with our proposal the following additional information for the subject package:
S. No. Brief description of Information Ref. and Page No.
Note: The Bidder should accordingly upload the scanned copies of the relevant documents (Refer Clause 15.4 of ITB, Sec - I of bidding documents).
Date: Printed Name :
Place:. Designation :
Tender Enquiry No. : ODP/BB/C&M-3575/OT-24/RFx No. 5002003243/23-24
S. No. Brief description of Information Ref. and Page No.
Date: Printed Name : 0
Place:. Designation : 0
Tender Enquiry No. : ODP/BB/C&M-3575/OT-24/RFx No. 5002003243/23-24 Attachment - 7
Construction of a Control Centre Building for OPTCL STAMS (State Transmission Asset Management System) Project by POWERGRID under Consultancy Services to OPTCL
(Work Completion Schedule)
Bidder’s Name and Address (Bidder) : To :
Name : POWER GRID CORPORATION OF INDIA LIMITED,
Address : ODISHA PROJECTS
PLOT NO.-4, UNIT-41, NILADRI VIHAR
CHANDRASHEKHARPUR, BHUBANESWAR-751021
We hereby declare that the following Work Completion Schedule shall be followed by us in furnishing and installation of the subject Package i.e., Construction of a Control Centre Building for OPTCL STAMS (State Transmission Asset Management System) Project by POWERGRID under Consultancy Services to OPTCL for the period commencing from the effective date of Contract :
Sl. No. Description of Work/ Activity Period in Months (from the effective date of LOA)
Commencement completion
Date : Printed Name :
Place : Designation :
Note : Bidders to enclose a detailed network covering all the activities to be undertaken for completion of the project indicating key dates for various milestones for each phase constituent-wise.
Tender Enquiry No. : ODP/BB/C&M-3575/OT-24/RFx No. 5002003243/23-24 Attachment-7A
Construction of a Control Centre Building for OPTCL STAMS (State Transmission Asset Management System) Project by POWERGRID under Consultancy Services to OPTCL
(Option for contract performance guarantee and Information for E – payment, PF details and declaration for Micro/Small and Medium Enterprise)
Bidder’s Name and Address (Bidder [Authorised Representative]) : To:
Name : POWER GRID CORPORATION OF INDIA LIMITED,
Address : ODISHA PROJECTS
PLOT NO.-4, UNIT-41, NILADRI VIHAR
CHANDRASHEKHARPUR, BHUBANESWAR-751021
I. We have read the provision in the Bidding Documents regarding furnishing of Contract Performance Guarantee.
we hereby confirm to opt the following:
I. Contract performance Guarantee will be submitted: Bank Guarantee
(Select from drop down list)
II. We are furnishing the following details of Statutory Registration Numbers and details of Bank for electronic payment.
1. Name of the Supplier/ Contractor in whose favour payment is to be made
2. Address with PIN Code and State
Registered Office:
Correspondence Address:
3. (a) Status – Company/others
[Declaration of Micro/ Small/ Medium Enterprise under Micro/ Small & Medium Enterprises Development Act 2006, if applicable]
3. (b) Are you a MSE owned by SC/ST* entrepreneurs in line with Public Procurement Policy for Micro and small Enterprises (MSEs) order 2012 including subsequent amendment/notification/order (Indicate Yes/No) Note: Documentary evidence is to be attached. Please refer remarks at the end of attachment
3. (c) If 3 (b) is ‘Yes’ please mention whether you are (Proprietary MSE/Partnership MSE/Private Limited Company) owned by SC/ST entrepreneurs
3. (d) Are you a MSE owned by women in line with Public Procurement Policy for Micro and Small Enterprises (MSEs) order 2012, Public Procurement Policy for Micro and Small Enterprises (MSEs) Amendment order 2018 including subsequent amendment/notification/ order (Indicate Yes/No) Note: Documentary evidence is to be attached.
4. Permanent Account (PAN) No.
6. Work Contract Tax No.
7. PF Registration No. of the Company
8. PF Regional Office covered (with Address)
9. Name of Contact Person
10. Telephone No(s)
11. Bank Details for Electronic Payment
Name of the Bank:
Address of Branch:
Type of Account:
Type of Account: Saving Account
12. 9 digit MICR code printed at bottom in middle, next to cheque no.
13. IFSC (for RTGS)/NEFT Code (to be obtained from the Bank) Sample Cancelled Cheque to be enclosed
We hereby declare that the above information are true and correct and we agree that the payment on account of this Contract, in the event of award, be made in the above account maintained in the above mentioned Bank.
Note: A cancelled cheque of the bank is enclosed.
*The definition of MSEs owned by SC/ST is as given under:
a. In case of proprietary MSE, proprietor(s) shall be SC/ST.
b. In case of partnership MSE, the SC/ST partners shall be holding at least 51% shares in the unit.
c. In case of Private Limited companies, at least 51% share shall be held by SC/ST promoters.
Documentary evidence: Please provide scanned copy(ies) of the SC/ST certificate(s) issued by District Authority as applicable for SC/ST MSE category as per (a), (b) or (c) above.
Date : Printed Name :
Place : Designation :
Tender Enquiry No. : ODP/BB/C&M-3575/OT-24/RFx No. 5002003243/23-24 Attachment - 8
Construction of a Control Centre Building for OPTCL STAMS (State Transmission Asset Management System) Project by POWERGRID under Consultancy Services to OPTCL
(Information regarding Ex-employees of POWERGRID in our Organisation)
Bidder’s Name and Address (Bidder) : To :
Name : POWER GRID CORPORATION OF INDIA LIMITED,
Address : ODISHA PROJECTS
PLOT NO.-4, UNIT-41, NILADRI VIHAR
We hereby furnish the details of ex-employees of POWERGRID who had retired/ resigned at the level of General Manager and above from POWERGRID and subsequently have been employed by us:
Sl. No. Name of the person with designation in POWERGRID Date of Retirement/ resignation from POWERGRID Date of joining and designation in our organisation
Date : Printed Name :
Place : Designation :
Tender Enquiry No. : ODP/BB/C&M-3575/OT-24/RFx No. 5002003243/23-24 Attachment - 8
Construction of a Control Centre Building for OPTCL STAMS (State Transmission Asset Management System) Project by POWERGRID under Consultancy Services to OPTCL
(Information regarding Ex-employees of POWERGRID in our Organisation)
Name(s) and Addresse(s) of other partner(s) To :
Other Partner-1 Sr. GM(C&M)
Name : POWER GRID CORPORATION OF INDIA LIMITED,
Address : ODISHA PROJECTS
PLOT NO.-4, UNIT-41, NILADRI VIHAR
We hereby furnish the details of ex-employees of POWERGRID who had retired/ resigned at the level of General Manager and above from POWERGRID and subsequently have been employed by us:
Sl. No. Name of the person with designation in POWERGRID Date of Retirement/ resignation from POWERGRID Date of joining and designation in our organisation
Date : Printed Name :
Place : Designation :
Tender Enquiry No. : ODP/BB/C&M-3575/OT-24/RFx No. 5002003243/23-24 Attachment - 8
Construction of a Control Centre Building for OPTCL STAMS (State Transmission Asset Management System) Project by POWERGRID under Consultancy Services to OPTCL
(Information regarding Ex-employees of POWERGRID in our Organisation)
Name(s) and Addresse(s) of other partner(s) To :
Other Partner-2 Sr. GM(C&M)
Name : POWER GRID CORPORATION OF INDIA LIMITED,
Address : ODISHA PROJECTS
PLOT NO.-4, UNIT-41, NILADRI VIHAR
We hereby furnish the details of ex-employees of POWERGRID who had retired/ resigned at the level of General Manager and above from POWERGRID and subsequently have been employed by us:
Sl. No. Name of the person with designation in POWERGRID Date of Retirement/ resignation from POWERGRID Date of joining and designation in our organisation
Date : Printed Name :
Place : Designation :
Tender Enquiry No. : ODP/BB/C&M-3575/OT-24/RFx No. 5002003243/23-24 Attachment-9
Construction of a Control Centre Building for OPTCL STAMS (State Transmission Asset Management System) Project by POWERGRID under Consultancy Services to OPTCL
(Declaration regarding Social Accountability)
Bidder’s Name and Address (Bidder) : To :
Name : POWER GRID CORPORATION OF INDIA LIMITED,
Address : ODISHA PROJECTS
PLOT NO.-4, UNIT-41, NILADRI VIHAR
CHANDRASHEKHARPUR, BHUBANESWAR-751021
We conform that we stand committed to comply to all requirements of Social Accountability Standards i.e., SA8000 (latest Standard available at www.sa-intl.org) and maintain the necessary records.
Date : Printed Name :
Place : Designation :
Tender Enquiry No. : ODP/BB/C&M-3575/OT-24/RFx No. 5002003243/23-24 Attachment-10
Construction of a Control Centre Building for OPTCL STAMS (State Transmission Asset Management System) Project by POWERGRID under Consultancy Services to OPTCL
(Declaration regarding Environmental management)
Bidder’s Name and Address (Bidder) : To :
Name : POWER GRID CORPORATION OF INDIA LIMITED,
Address : ODISHA PROJECTS
PLOT NO.-4, UNIT-41, NILADRI VIHAR
CHANDRASHEKHARPUR, BHUBANESWAR-751021
We conform that we stand committed to comply to all requirements of "Environmental management system " i.e. ISO 14001 (latest Standard available at www.iso.org) and maintain the necessary records.
Date : Printed Name :
Place : Designation :
Tender Enquiry No. : ODP/BB/C&M-3575/OT-24/RFx No. 5002003243/23-24 Attachment-11
Construction of a Control Centre Building for OPTCL STAMS (State Transmission Asset Management System) Project by POWERGRID under Consultancy Services to OPTCL
Bidder’s Name and Address (Bidder) : To :
Name : POWER GRID CORPORATION OF INDIA LIMITED,
Address : ODISHA PROJECTS
PLOT NO.-4, UNIT-41, NILADRI VIHAR
CHANDRASHEKHARPUR, BHUBANESWAR-751021
"Integrity Pact is Applicable for this Package"
Date : Printed Name :
Place : Designation :
Tender Enquiry No. : ODP/BB/C&M-3575/OT-24/RFx No. 5002003243/23-24 Attachment- 12 08 (Eight)
Construction of a Control Centre Building for OPTCL STAMS (State Transmission Asset Management System) Project by POWERGRID under Consultancy Services to OPTCL
(Price Adjustment Data)
PRICE VARIATION IS NOT APPLICABLE FOR THIS PACKAGE
Bidder’s Name and Address (Bidder) : To :
Name : POWER GRID CORPORATION OF INDIA LIMITED,
Address : ODISHA PROJECTS
PLOT NO.-4, UNIT-41, NILADRI VIHAR
We hereby furnish the relevant details pertaining to the price adjustment provisions for equipment as specified in your specifications and documents for the Construction of a Control Centre Building for OPTCL STAMS (State Transmission Asset Management System) Project by POWERGRID under Consultancy Services to OPTCLThe necessary documentary evidence are enclosed :
Sl. No. Name of Materials/Labour Name of the published index Value of index (30 days prior to date of opening of bids)
1 Supply & Placement of Reinforcement Steel
A High Speed Diesel coefficient Wholesale Price Index Number for ‘High Speed Diesel’ (Individual commodity) (monthly) (Base: 2004-05=100) as published by Office of Economic Advisor, Ministry of Commerce & Industry (www.eaindustry.nic.in).
L Labour coefficient Indian Labour Bureau, Shimla, Govt. of India (monthly) (Base: 2001 = 100) (www.labourbureau.nic.in)
B Ferrous Metals coefficient Wholesale Price Index Number for ‘Ferrous Metals’ (Group Item) (monthly) (Base: 2004-05=100) as published by Office of Economic Advisor, Ministry of Commerce & Industry (www.eaindustry.nic.in).
2 For Concreting
A High Speed Diesel, coefficient a = Wholesale Price Index Number for High Speed Diesel’ (Individual commodity) (monthly) (Base: 2004-05=100) as published by Office of Economic Advisor, Ministry of Commerce & Industry (www.eaindustry.nic.in).
L Labour, coefficient l = Indian Labour Bureau, Shimla, Govt. of India (monthly) (Base: 2001 = 100) (www.labourbureau.nic.in)
B Cement & Lime, coefficient b = Wholesale Price Index Number for ‘Cement & Lime’ (Group Item) (monthly) (Base: 2004-05=100) as published by Office of Economic Advisor, Ministry of Commerce & Industry (www.eaindustry.nic.in).
C Structural Clay Products coefficient Wholesale Price Index Number for ‘Structural Clay Products’ (Group Item) (monthly) (Base: 2004-05=100) as published by Office of Economic Advisor, Ministry of Commerce & Industry (www.eaindustry.nic.in).
The Bidders are required to indicate the value of indices for various components as of 30 days prior to the date of bid opening. In case bid opening date is extended after submission of bids because of any reason, indices as of 30 days prior to actual date of bid opening shall be considered for placement of award and for payment towards price adjustment.
Date : Printed Name :
Place : Designation :
Instruction for printing & submitting Integrity Pact
1. The requisite format of Integrity Pact is getting generated automatically and displayed here below.
2. Take print out of first page on a non-judicial stamp paper of Rs. 100/- purchased in Bidder's name and other seven pages on plain A4 size paper. Such two sets shall be prepared by the bidder.
3. All the pages of both the copies of the Integrity Pact shall be signed by the authorised representative of the bidder and duly stamped.
4. Both the original copies shall be submitted by the bidder in the form of Hard Copy as part of the first envelope before due date & time of submission of the bid.
5. For further details bidders may please refer ITB Clause 9.3 (n).
Applicable for this Package and
enclosed at Annexure-I
Power Grid Corporation of India Limited
having its Registered Office at B-9, Qutab Institutional Area, Katwaria Sarai, New Delhi – 110016 hereinafter referred to as
having its Registered Office at
having its Registered Office at FALSE
hereinafter referred to as
"The Bidder/Contractor"
POWERGRID intends to award, under laid-down organisational procedures, contract(s) for Construction of a Control Centre Building for OPTCL STAMS (State Transmission Asset Management System) Project by POWERGRID under Consultancy Services to OPTCL
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Integrity Pact Page 1 of 8
Construction of a Control Centre Building for OPTCL STAMS (State Transmission Asset Management System) Project by POWERGRID under Consultancy Services to OPTCL Package and Specification Number ODP/BB/C&M-3575/OT-24/RFx No. 5002003243/23-24 POWERGRID values full compliance with all relevant laws and regulations, and the principles of economic use of resources, and of fairness and transparency in its relations with its Bidders/ Contractors.
In order to achieve these goals, POWERGRID and the above named Bidder/Contractor enter into this agreement called 'Integrity Pact' which will form a part of the bid.
It is hereby agreed by and between the parties as under:
Section I - Commitments of POWERGRID
(1) POWERGRID commits itself to take all measures necessary to prevent corruption and to observe the following principles :
a) No employee of POWERGRID, personally or through family members, will in connection with the tender, or the execution of the contract, demand, take a promise for or accept, for him/herself or third person, any material or other benefit which he/she is not legally entitled to.
b) POWERGRID will, during the tender process treat all Bidder(s) with equity and fairness and reason. POWERGRID will in particular, before and during the tender process, provide to all Bidder(s) the same information and will not provide to any Bidder(s) confidential/ additional information through which the Bidder(s) could obtain an advantage in relation to the tender process or the contract execution.
c) POWERGRID will exclude from evaluation of Bids its such employee(s) who has any personal interest in the Companies/Agencies participating in the Bidding/Tendering process.
(2) If POWERGRID obtains information on the conduct of any of its employee which is a criminal offence under the IPC/PC Act , or if there be a substantive suspicion in this regard, POWERGRID will inform its Chief Vigilance Officer and in addition disciplinary actions can be initiated under POWERGRID's Rules.
Section II - Commitments of the Bidder/Contractor
(1) The Bidder/Contractor commits itself to take all measures necessary to prevent corruption. The Bidder/Contractor commits itself to observe the following principles during his participation in the tender process and during the contract execution :
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Integrity Pact Page 2 of 8
a) The Bidder/Contractor will not, directly or through any other person or firm, offer, promise or give to any of POWERGRID's employees involved in the tender process or the execution of the contract or to any third person any material or other benefit which it is not legally entitled to, in order to obtain in exchange an advantage of any kind whatsoever during the tender process or the execution of the contract.
b) The Bidder/Contractor will not enter into any illegal or undisclosed agreement or understanding, whether formal or informal with other Bidders/Contractors. This applies in particular to prices, specifications, certifications, subsidiary contracts, submission or non-submission of bids or actions to restrict competitiveness or to introduce cartelization in the bidding process.
c) The Bidder/Contractor shall not pass any information provided by POWERGRID as part of business relationship to others and shall not commit any offence under PC/IPC Act.
d) The Bidder/Contractor of foreign origin shall disclose the name and address of the Agents/representatives in India, if any, involved directly or indirectly in the Bidding. Similarly, the Bidder/Contractor of Indian Nationality shall furnish the name and address of the foreign principals, if any, involved directly or indirectly in the Bidding.
e) The Bidder/Contractor will, when presenting his bid, disclose any and all payments made, or committed to or intends to make to agents, brokers or any other intermediaries in connection with the award of the contract and/or with the execution of the contract.
f) The Bidder/Contractor will not misrepresent facts or furnish false/forged documents/informations in order to influence the bidding process or the execution of the contract to the detriment of POWERGRID.
g) The Bidder/Contractor shall ensure adoption of Integrity Pact by its Sub-contractors and shall be responsible for the same
(2) The Bidder/Contractor will not instigate third persons to commit offences outlined above or be an accessory to such offences.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Integrity Pact Page 3 of 8
Section III- Disqualification from tender process and exclusion from future contracts
(1) If the Bidder, before contract award, has committed a transgression through a violation of Section II or in any other form such as to put his reliability or credibility as Bidder into question, POWERGRID may disqualify the Bidder from the tender process or terminate the contract, if already signed, for such reason.
(2) If the Bidder/Contractor has committed a transgression through a violation of Section II such as to put his reliability or credibility into question, POWERGRID may after following due procedures, ban/blacklist the Bidder/Contrator in line with POWERGRID's policy for Black-Listing of Firms/Banning of Business". The imposition and duration of the ban will be determined by the severity of the transgression. The severity will be determined by the circumstances of the case, in particular the number of transgressions, the position of the transgressors within the company hierarchy of the Bidder/Contractor and the amount of the damage. The ban will be imposed for a maximum of 3 years.
(3) If the Bidder/Contractor can prove that he has restored/recouped the damage caused by him and has installed a suitable corruption prevention system, POWERGRID may revoke the ban prematurely.
Section IV - Liability for violation of Integrity Pact
(1) If POWERGRID has disqualified the Bidder from the tender process prior to the award under Section III, POWERGRID is entitled for forfeiture of the Bid Guarantee under the Bid.
(2) If POWERGRID has terminated the contract under Section III or if POWERGRID is entitled to terminate the contract under Section-III, POWERGRID shall be entitled to forfeit the Contract Performance Guarantee of this contract, in full or part thereof as may be decided, besides resorting to other remedies under the contract.
Section V- Previous Transgression
(1) The Bidder shall disclose in its Bid any transgressions occurred in the last 10 years with any other Public Sector Undertaking or Government Department or any other company, in any country, that may impinge on the Anti-Corruption principle.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Integrity Pact Page 4 of 8
(2) If the Bidder makes incorrect statement on this subject, it can be disqualified from the tender process or the contract, if already awarded, can be terminated for such reason and further action can be taken in line with POWERGRID's policies.
Section VI - Equal treatment to all Bidders / Contractors
(1) POWERGRID will enter into agreements with identical conditions as this one with all Bidders.
(2) POWERGRID will disqualify from the tender process any bidder who does not sign this Pact or violate its provisions.
Section VII - Punitive Action against violating Bidders / Contractors
If POWERGRID obtains knowledge of conduct of a Bidder or a Contractor or his subcontractor or of an employee or a representative or an associate of a Bidder or Contractor or his Subcontractor which constitutes corruption, or if POWERGRID has substantive suspicion in this regard, POWERGRID will inform the Chief Vigilance Officer (CVO).
(*)Section VIII - Independent External Monitor/Monitors
(1) POWERGRID has appointed a panel of Independent External Monitors (IEMs) for this Pact with the approval of Central Vigilance Commission (CVC), Government of India. The names of IEMs have been indicated in the Bidding Documents.
(2) The panel of IEMs shall review independently and objectively, whether and to what extent the parties comply with the obligations under this agreement. The panel of IEMs has right of access to all project documentation. The panel of IEMs may examine any complaint received by them and submit a report to Chairman-cum-Managing Director, POWERGRID, giving joint findings at the earliest. The panel of IEMs may also submit a report directly to the CVO and the CVC, in case of suspicion of serious irregularities attracting the provisions of the PC Act.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Integrity Pact Page 5 of 8
(3) The IEM is not subject to instructions by the representatives of the parties and performs his functions neutrally and independently. He/She reports to the Chairman-cum-Managing Director, POWERGRID.
(4) The Bidder(s)/Contractor(s) accepts that the IEM has the right to access without restriction to all documentation of POWERGRID related to this contract including that provided by the Contractor/Bidder. The Bidder/Contractor will also grant the IEM, upon his/her request and demonstration of a valid interest, unrestricted and unconditional access to their documentation. The same is applicable to Subcontractors. The IEM is under contractual obligation to treat the information and documents of the Bidder(s)/Contractor(s)/Subcontractor(s) with confidentiality.
(5) POWERGRID will provide to the IEM information as sought by him/her which could have an impact on the contractual relations between POWERGRID and the Bidder/Contractor related to this contract. The IEMs shall also sign declaration on 'Non-Disclosure of Confidential Information' and of 'Absence of Conflict of Interest'. In case of any conflict of interest arising at a later date, the IEM shall inform Chairman-cum-Managing Director, POWERGRID and recuse himself/herself from that case.
(6) As soon as the IEM notices, or believes to notice, a violation of this agreement, he/she will so inform the Chairman-cum-Managing Director, POWERGRID and request the Chairman-cum-Managing Director, POWERGRID to discontinue or take corrective action, or to take other relevant action. The IEM can in this regard submit non-binding recommendations. Beyond this, the IEM has no right to demand from the parties that they act in a specific manner, refrain from action or tolerate action. However, the IEM shall give an opportunity to POWERGRID and the Bidder/Contractor, as deemed fit, to present its case before making its recommendations to POWERGRID.
(7) The IEM will submit a written report to the Chairman-cum-Managing Director, POWERGRID within 8 to 10 weeks from the date of reference or intimation to him by POWERGRID and, should the occasion arise, submit proposals for correcting problematic situations.
(8) If the IEM has reported to the Chairman-cum-Managing Director, POWERGRID, a substantiated suspicion of an offence under PC/IPC Act, and the Chairman-cum-Managing Director, POWERGRID has not, within the reasonable time taken visible action to proceed against such offence or reported it to the CVO, the Monitor may also transmit this information directly to the CVC, Government of India.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Integrity Pact Page 6 of 8
(9) While representing any matter in relation to the Integrity Pact inter-alia including its transgression to the panel of IEMs, POWERGRID and Bidder/Contractor shall not approach the court of law and await the decision of the IEM in the matter.
(10) The word ‘IEM’ would include both singular and plural.
(*) This Section shall be applicable for only those packages wherein the IEMs have been identified in Section – I : Invitation for Bids and/or Clause ITB 9.3 in Section – III: Bid Data Sheets of Conditions of Contract, Volume-I of the Bidding Documents.
Section IX - Pact Duration
This Pact begins when both parties have legally signed it. It expires for the Contractor after the closure of the contract and for all other Bidder's six month after the contract has been awarded.
Section X - Other Provisions
(1) This agreement is subject to Indian Law. Place of performance and jurisdiction is the establishment of POWERGRID. The Arbitration clause provided in the main tender document / contract shall not be applicable for any issue / dispute arising under Integrity Pact.
(2) Changes and supplements as well as termination notices need to be made in writing. Side Agreements have not been made.
(3) If the Contractor is a partnership firm or a consortium or Joint Venture, this agreement must be signed by all partners, consortium members and Joint Venture partners.
(4) Nothing in this agreement shall affect the rights of the parties available under the General Conditions of Contract (GCC) and Special Conditions of Contract (SCC).
(5) Issues like Warranty/Guarantees etc. shall be outside the purview of IEMs.
(6) Views expressed or suggestions/submissions made by the parties and the recommendations of the CVO/IEM# in respect of the violation of this agreement, shall not be relied on or introduced as evidence in the arbitral or judicial proceedings (arising out of the arbitral proceedings) by the parties in connection with the disputes/differences arising out of the subject contract.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Integrity Pact Page 7 of 8
# CVO shall be applicable for packages wherein IEM are not identified in Section IFB/BDS of Condition of Contract, Volume-I. IEM shall be applicable for packages wherein IEM are identified in Section IFB/BDS of Condition of Contract, Volume-I.
(6) Should one or several provisions of this agreement turn out to be invalid, the remainder of this agreement remains valid. In this case, the parties will strive to come to an agreement to their original intentions.
Signature Signature
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
(Office Seal) (Office Seal)
Designation : Designation :
Witness 1 : Witness 1 :
Designation : Designation :
Witness 2 : Witness 2 :
Designation : Designation :
Integrity Pact Page 8 of 8
Tender Enquiry No. : ODP/BB/C&M-3575/OT-24/RFx No. 5002003243/23-24 Attachment-12
Construction of a Control Centre Building for OPTCL STAMS (State Transmission Asset Management System) Project by POWERGRID under Consultancy Services to OPTCL
(Price Adjustment Data)
Bidder’s Name and Address (Bidder [Authorised Representative]) : To:
Name : Power Grid Corporation of India Ltd.,
Address : Odisha Projects
Plot No-4,Unit-41,Niladri Vihar
Chandrashekharpur, Bhubaneswar-751021
We hereby furnish the relevant details pertaining to the price adjustment for equipment as specified in your specifications & documents for the package: Construction of a Control Centre Building for OPTCL STAMS (State Transmission Asset Management System) Project by POWERGRID under Consultancy Services to OPTCL
Sl. No. Name of Materials Value of co-efficient # Name of the published index * Value of index as 30 days prior to date set for opening of bids as on **
1 Installation Price Component {including Civil Works but excluding 'Supply & placement of Reinforcement Steel', ' Concreting, Survey, Soil Investigation and aviation signal for River Crossing towers (if any)}
A High Speed Diesel (Co-efficient=a), Value of which shall be between 0.20 & 0.24 Wholesale Price index Number for 'HSD' (Individual Commodity) (monthly) (Base: 2011-12=100), as published by office of Economic Advisor, Ministry of Commerce & Industry (www.esindustry.nic.in)
L Labour (Co-efficient=l), Value of which shall be between 0.56 & 0.60 Indian field labour index namely All India average consumer price index for Industrial Workers (monthly) (Base: 2016= 100), as published by Labour Bureau, Shimla, Government of India (www.labourbureau.nic.in).
*Note: Sum of a & l shall be 0.80 for above.
2 Supply & Placement of Reinforcement Steel
A High Speed Diesel (Co-efficient=a) ,Value of which shall be between 0.09 & 0.11 Wholesale Price index Number for 'HSD' (Individual Commodity) (monthly) (Base: 2011-12=100), as published by office of Economic Advisor, Ministry of Commerce & Industry (www.esindustry.nic.in)
L Labour (Co-efficient=l), Value of which shall be between 0.04 & 0.06 Indian field labour index namely All India average consumer price index for Industrial Workers (monthly) (Base: 2016= 100), as published by Labour Bureau, Shimla, Government of India (www.labourbureau.nic.in).
B Manufacture of Basic Metals (Co-efficient=b), Value of which shall be between 0.63 & 0.67 Wholesale Price Index Number for `Manufacture of Basic Metals' (Group Item) (monthly) (Base: 2011-12=100), as published by Office of Economic Advisor, Ministry of Commerce & Industry(www.eaindustry.nic.in).
*Note: Sum of a, b & l shall be 0.80 for above.
3 For Concreting
A High Speed Diesel (Co-efficient=a), Value of which shall be between 0.18 & 0.22 Wholesale Price index Number for 'HSD' (Individual Commodity) (monthly) (Base: 2011-12=100), as published by office of Economic Advisor, Ministry of Commerce & Industry (www.esindustry.nic.in)
L Labour (Co-efficient=l), Value of which shall be between 0.09 & 0.11 Indian field labour index namely All India average consumer price index for Industrial Workers (monthly) (Base: 2016= 100), as published by Labour Bureau, Shimla, Government of India (www.labourbureau.nic.in).
B Manufacture of Cement, lime and plaster (Co-efficient=b), Value of which shall be between 0.25 & 0.35 Wholesale Price Index Number for `Manufacture of cement, lime and plaster ‘ (Group Item) (monthly) (Base: 2011-12=100), as published by Office of Economic Advisor, Ministry of Commerce & Industry (www.eaindustry.nic.in).
C Cutting,Shaping and finishing of Stone (Co-efficient=c ), Value of which shall be between 0.18 & 0.22 Wholesale Price Index Number for `Cutting, shaping and finishing of stone’ (Group Item) (monthly) (Base: 2011-12=100), as published by Office of Economic Advisor, Ministry of Commerce & industry.nic.in). (www.eaindustry.nic.in).
*Note: Sum of a, b, c & l shall be 0.80 for above.
The Bidders are required to indicate the value of indices for varoius components as of 30 Days prior to the date of bid Opening. In case bid opening date is extended after submission of bids because of any reason,indices as of 30 days prior to actual date of bid opening shall be considered for placement of award and for payment towards price adjustment.
Note: # Indicate the Coefficient.
* Indicate the publisher of the index.
** Indicate the date of indices for which the values are being furnished.
Date : 00-Jan-00 Printed Name : 0
Place : 0 Designation : 0
Tender Enquiry No. : ODP/BB/C&M-3575/OT-24/RFx No. 5002003243/23-24 Attachment-13
Construction of a Control Centre Building for OPTCL STAMS (State Transmission Asset Management System) Project by POWERGRID under Consultancy Services to OPTCL
Bidder’s Name and Address (Bidder) : To :
POWER GRID CORPORATION OF INDIA LIMITED,
Name : ODISHA PROJECTS
Address : PLOT NO.-4, UNIT-41, NILADRI VIHAR
CHANDRASHEKHARPUR, BHUBANESWAR-751021
Further, we hereby confirm that except as mentioned in the Attachment -4 (Commercial Deviations), Attachment -5 (Technical Deviations) and Attachment - 5A (Deviations on important/critical conditions along with their withdrawal price) thereof , forming part of our First Envelope:
(i) there are no discrepencies/inconsistencies and deviations/omissions/reservations to the Bidding Documents, in the Second Envelope bid;
We also confirm that in case any discrepencies/inconsitencies and deviations/omissions/reservations, as referred to in para (i) and (ii) above, is observed in the Second Envelope, the same shall be deemed as withdrawn/rectified without any finacial implication, whatsoever to POWERGRID. However, in case of any artithmetical errors, the same shall be governed as per the provisions of ITB Sub-clause 26.3 read in conjuction with BDS.
Date : Printed Name :
Place : Designation :
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
23 Twenty Three
27 Twenty Seven
28 Twenty Eight
33 Thirty Three
37 Thirty Seven
38 Thirty Eight
73 Seventy Three
74 Seventy Four
75 Seventy Five
77 Seventy Seven
78 Seventy Eight
79 Seventy Nine
83 Eighty Three
87 Eighty Seven
88 Eighty Eight
93 Ninety Three
97 Ninety Seven
98 Ninety Eight
100 One Hundred
Tender Enquiry No. : ODP/BB/C&M-3575/OT-24/RFx No. 5002003243/23-24 Attachment-14
Construction of a Control Centre Building for OPTCL STAMS (State Transmission Asset Management System) Project by POWERGRID under Consultancy Services to OPTCL
(Additional Information)
Bidder’s Name and Address (Bidder [Authorised Representative]) : To:
Name : Power Grid Corporation of India Ltd.,
Address : Odisha Projects
Plot No-4,Unit-41,Niladri Vihar
Chandrashekharpur, Bhubaneswar-751021
In support of the additional information required as per ITB Sub-Clause 9.3 (p) of the Bidding Documents, we furnish herewith our data/details/documents etc., alongwith other information, as follows (the stipulations have been reproduced in italics for ready reference):
1.0 The Bidder shall furnish
A certificate from their Banker(s) (as per prescribed formats in Form 16, Section-VI: Sample Forms and Procedures) indicating various fund based/non fund based limits sanctioned to the Bidder and the extent of utilization as on date. Such certificate should have been issued not earlier than three months prior to the date of bid opening. Wherever necessary the Employer may make queries with the Bidders’ Bankers. [Reference ITB clause 9.3(p)(i)]
1.1 In accordance with 1.0, certificate(s) from banker as per requisite format, indicating various fund based/non fund based limits sanctioned to the bidder or each member of the joint venture and the extent of utilization as on date is/are enclosed, as per the following details:
Name of the (Bidder [Authorised Representative]) :
Name of the Banker by whom certificate issued
Date of certificate (should not be earlier than 3 months prior to date of bid opening)
Whether fund based/non fund based limits are indicated in the certificate
Whether extent of utilization is indicated in the certificate
1.2 The Bidder should accordingly also provide the following information/documents
(i) Details of Banker:
Address of Banker
Contact Name and Title
(ii) As per para 1.0, Authorization Letter(s) from the bidder addressed to the Banker(s), authorizing POWERGRID to seek queries about the bidder with the Banker(s) and advising the Banker(s) to reply the same promptly, is/are enclosed as per following details:
Sl. No. Letter Ref. Date Addressed to (name of the Bank)
1.0 Litigation History
The bidder should provide detailed information on any litigation or arbitration arising out of contracts completed or under execution by it over the last five years. A consistent history of awards involving litigation against the Bidder or any partner of JV may result in rejection of Bid. [Reference ITB clause 9.3(p)(ii)]
1.1 Details of litigation history resulting from Contracts completed or under execution by the bidder over the last five years
Year Name of client, cause of litigation/arbitration and matter in dispute Details of Contract and date Award for or against the bidder Disputed amount
2.0 Description of the plant for carrying out the work
Bidders should provide information of the plant(s) for carrying out the work including the proposal of manufacturing methods in sufficient detail to demonstrate the adequacy of the bidder’s proposals to meet the technical specification.
3.0 OTHER INFORMATION
3.1 Current Contract Commitments of works in progress
Bidders should provide information on their current commitments on all contracts that have been awarded, or for which a letter of intent or acceptance has been received, or for contracts approaching completion, but for which an unqualified, full completion certificate has yet to be issued.
Details of Contract Type of Conductor Ordered Quantity as per Contract Balance Quantity to be supplied as on Completion Period for balance quantity
Commencement Completion
3.2 Financial Data:
Details Actual (Previous five years) Projection for next five years
Total Liability
Current Liability
Profit before taxes
Profit after taxes
Date : 00-Jan-00 Printed Name : 0
Place : 0 Designation : 0
Tender Enquiry No. : ODP/BB/C&M-3575/OT-24/RFx No. 5002003243/23-24 Bid Form 1st Envelope JV (Joint Venture)
2 or More FALSE FALSE
BID PROPOSAL FORM (First Envelope) We are NSIC/MSME registered and exempted from submission of Bid Guarantee as per the provision of clause no. 13.7 of ITB, Section -IV, Vol-I of bidding documents. We have enclosed a copy of NSIC Certificate reference no. dated DD-MM-YYYY and the issued certificate is valid upto and inclusive of DD-MM-YYYY. It is to confirm that the equipment(s)/item(s)/material(s) quoted in our bid is in the list of items indicated in NSIC certificate enclosed. We have enclosed a Bid Guarantee in original and one copy in the form of FDR (FDR No.-, dated DD-MM-YYYY issued from ) for a sum of Rupees /-, Valid for a period of Seven [07] calendar months from the date of opening of bids i.e. upto and inclusive of DD-MM-YYYY. Tick only one Option (Yes/No)
FDR No. Tick at least one Option (Yes/No)
Bid Proposal Ref. No. NSIC Certificate No.
POWER GRID CORPORATION OF INDIA LIMITED,
ODISHA PROJECTS
PLOT NO.-4, UNIT-41, NILADRI VIHAR
CHANDRASHEKHARPUR, BHUBANESWAR-751021
All the prices and the price components stated in our bid price are firm in accordance with provisions of the bidding documents. All the prices and other terms and conditions of this proposal are valid for a period of Six [06] calendar Months from the date of opening of the bid i.e. up to and inclusive of
Name of Contract : Construction of a Control Centre Building for OPTCL STAMS (State Transmission Asset Management System) Project by POWERGRID under Consultancy Services to OPTCL
Dear Ladies and/or Gentlemen,
1.0 We, the undersigned Bidder, having read and examined in detail the specification and documents of the subject package including amendment, if any, do hereby propose for Construction of a Control Centre Building for OPTCL STAMS (State Transmission Asset Management System) Project by POWERGRID under Consultancy Services to OPTCL as detailed in the specification and the bidding documents for the subject package. EMD DETAIL FORM Tick at least one Option (Yes/No)
Are you MSE Registered: Yes No
Select the Form of EMD : FDR
2.0 BID GUARANTEE/Earnest Money Deposit(EMD): NOT APPLICABLE. The bidder has to submit Bid Securing Declaration FDR No.
2.1 Tick at least one Option (Yes/No) Name of Issuing Bank :
Amount of EMD/ Bank Guarantee :
Date of Issuance DD MM YYYY
Valid up to DD MM YYYY
2.2 If I/We fail to keep the tender open as aforesaid or make any modifications in the terms and conditions of the tender which are not acceptable to POWERGRID, I/we agree that the POWERGRID shall without prejudice to any other right or remedy, be at liberty to forfeit the said earnest money absolutely. Should this tender be accepted, I/we hereby agree to abide by and fulfill all the terms, conditions and provisions of the aforesaid documents.
2.3 If, after the tender is accepted and I/we fail to commence the execution of the works as provided in the conditions, I/we agree that the corporation shall without prejudice to any other right or remedy be at liberty to forfeit the said earnest money absolutely.
3.0 PRICES & VALIDITY :
3.1 We understand that all prices and price components stated in the bid shall remain firm and not subject to any price adjustment, in line with the bidding documents. All prices and other terms and conditions of this proposal are valid for a period of 180 (One hundred Eighty) days from the date of opening of the price bids. We further declare that prices stated in our proposal are in accordance with your bidding documents.
3.2 Further, we confirm that we have read all the provisions in the Invitation for Bid (IFB), Instructions to bidders (ITB), Conditions of Contract for Civil Works and that of Special Conditions of Contract (SCC) (inclusive of those regarding applicable taxes, duties and levies in relevant clauses), Technical specifications & other documents and have submitted the bid accordingly.
3.3 We do hereby confirm that our bid prices quoted in our Proposal include, all costs such as cost of necessary materials, their transportation to site, cost towards tools, equipment and machineries including cost of personnel that may be required for successful completion of the work/s as per the Technical Specifications, including cost of site arrangement, overheads, insurance, whatsoever, as stipulated in the bidding documents for the total scope of work/s and all applicable taxes, duties and levies for all transactions between us and our sub-contractors as well as for all transactions between us and POWERGRID. We understand that Owner shall not entertain any claim on account of any taxes, duties or other levies or any interest therein.
3.4 We confirm that except as otherwise specifically provided our Bid Prices in Second Envelope include all taxes, duties, levies and charges as may be assessed on us, our Sub-Contractor/Sub-Vendor or their employees by all municipal, state or national government authorities in connection with the Goods, in and outside of India.
100% of applicable Taxes and Duties i.e. GST, which are payable by the Purchaser under the Contract, shall be reimbursed by the Purchaser on production of satisfactory documentary evidence by the Supplier in accordance with the provisions of the Bidding Documents.
3.5 We confirm that we have also registered/we shall also get registered in the GST Network with a GSTIN, in all the states from which we shall make our supply of goods.
3.6 We declare that items left blank in the Schedules will be deemed to have been included in other items. The total for each schedule and the total of grand summary shall be deemed to be the total price for executing the facilities and sections thereof in complete accordance with the Contract, whether or not each individual item has been priced.
5.0 DEVIATIONS:
5.1 We declare that the Contract shall be executed strictly in accordance with the specifications and documents except for the variations and deviations, all of which have been detailed out exhaustively in the following schedules, irrespective of whatever has been stated to the contrary anywhere else in our proposal.
a) Schedule of Commercial Deviations
b) Schedule of Cost of withdrawal of Deviations
c) Schedule of Technical Deviations
5.2 We confirm that specified stipulation of following critical clauses are acceptable to us and no deviations/exceptions are taken on any account whatsoever in the following clauses:
[a] Bid Security/ Bid Guarantee Clause No 13.0, ITB, Section -II and cl. 3.0 SCC, Section-IV, Volume-I
[b] Terms of Payment Clause No.64.0, Conditions of Contract (GCC) & Clause 11.0, SCC
[c] Contract Performance Guarantee/Performance Security Clause No.14,Section GCC, Vol.-I ,Conditions of Contract & Clause 12.0 of SCC, Section-IV, Vol-I & Clause 33.0 of ITB, Volume-I
[d] Liquidated Damages Clause No 10.0 of SCC, Volume-I
[e] Price & Price Basis Clause No 11.0 of ITB,
[f] Guarantee & Defect Liability Period Cl.No.45.0 & 46.0 Section. GCC, Vol. I, Conditions of Contract & Clause 8.0 of SCC, Volume- I
[g] Work schedule Clause No. 9.0 of SCC, Volume -I
5.3 In line with Clause 2.6 of Special Conditions of Contract, Volume I-A, we have declared the withdrawal price in Attachment – 5A for the deviations taken against the Clauses mentioned above and we undertake to execute the contract inline with the provisions of these clauses in case POWERGRID agree to bear the withdrawal cost.
5.4 Further, we agree that additional conditions, deviations, if any found in the proposal documents other than those stated in deviation Schedules, save that pertaining to any rebates offered, shall not be given effect to.
6.0 WORK SCHEDULE:
6.1 If this proposal is accepted by you, we agree to arrange site visit, submit Engineering data, provide services and complete the entire work from time to time in accordance with schedules indicated in the proposal. We fully understand that the time schedule stipulated in the proposal is the essence of the contract, if awarded. The completion schedule of the various major key phases of the Package is indicated.
7.0 CONTRACT PERFORMANCE GUARANTEE:
7.1 We further agree that if our proposal is accepted we shall provide an irrevocable Contract Performance Guarantee, within 15 days from LOA of value equivalent to ten percent (10%) of the Contract Price valid upto the end of ninety (90) days after the end of the contract warranty period in the form of ......................................... (Please specify the form of Guarantee) ……………... in your favour and enter into a formal agreement with you within Fifteen (15) days from the date of issue of Letter of Award of Contract.
8.0 Information regarding Ex-employees of POWERGRID who had retired/resigned at the level of General Manager and above from POWERGRID and subsequently have been employed by us; any other information in addition to the information called for in the proposal sheets and checklist duly filled in is enclosed as per respective schedules/ attachments.
9.0 We hereby declare that only the persons or firms interested in this proposal as principal or principals are named herein and that no other persons or firms other than those mentioned herein have any interest in this proposal or in the Contract to be entered into, if we are awarded the contract, that this proposal is made without any connection with any other person, firm or party like-wise submitting a proposal and that this proposal is in all respects for and in good faith, without collusion or fraud.
Thanking you, we remain,
Yours faithfully,
For and on behalf of
Date : Printed Name :
Place : Designation :
Please provide additional information of the Bidder 1 Jan 1990
Business Address : 2 Feb 1991
Name of Principal Officer : 5 May 1994
Address of Principal Officer : 6 Jun 1995
Note: (i) Written power of Attorney of Signatories of bid to commit the Bidder must be enclosed with the bid. (ii) Bidders may note that no prescribed proforma has been enclosed for Attachment -2 i.e. Power of Attorney. (iii) Bidders may use their own proforma for furnishing the required information with the bid. 9 Sep 1998 1 one 1 st 1 January
10 Oct 1999 2 two 2 nd 2 February
11 Nov 2000 3 three 3 rd 3 March
12 Dec 2001 4 four 4 th 4 April
13 Jan 2002 5 five 5 th 5 May
14 Feb 2003 6 six 6 th #VALUE! 6 June
15 Mar 2004 7 seven 7 th #VALUE! 7 July
16 Apr 2005 8 eight 8 th #VALUE! 8 August
17 May 2006 9 nine 9 th #VALUE! 9 September
18 Jun 2007 10 ten 10 th 10 October
19 Jul 2008 11 eleven 11 th 11 November
20 Aug 2009 12 twelve 12 th 12 December
21 Sep 2010 13 thirteen 13 th
22 Oct 2011 14 fourteen 14 th
23 Nov 2012 15 fifteen 15 th
24 Dec 2013 16 sixteen 16 th
25 2014 the receipt of which is hereby acknowledged, we the undersigned, offer to design, manufacture, test, deliver, install and commission (including carrying out Trial operation, Performance & Guarantee Test as per the provision of Technical Specification) the Facilities under the above-named package in full conformity with the said Bidding Documents. In accordance with ITB Clause 9.1 of the Bidding Documents, as per which the bid shall be submitted by the bidder under “Single Stage - Two Envelope” procedure of bidding. Accordingly, we hereby submit our Bid, in two envelopes i.e. First Envelope – Techno – Commercial Part & Second Envelope - Price Part (to be opened subsequently). 17 seventeen 17 th
26 2015 Bank Draft 18 eighteen 18 th
27 2016 Pay Order 19 nineteen 19 th
28 2017 Banks certified Cheque Zero 20 twenty 20 th
29 2018 Bank Guarantee #REF! 21 st
Applicable 23 th
Not Applicable 24 th
Indicative Make List for the package: Construction of a Control Centre Building for OPTCL STAMS (State Transmission Asset Management System) Project by POWERGRID under Consultancy Services to OPTCL
Video Surveillance System(IP CCTV)
S.No. Description Make / Model Remarks
1 Supply, installation, testing and commissioning of DOME CAMERA • Max. 2megapixel (1920 x 1080) resolution • 0.03Lux (Color), 0Lux (B/W, IR LED on) • 2.8mm fixed lens • Max. 30fps@2M all resolutions (H.265/H.264) • H.265, H.264, MJPEG codec supported, Multiple streaming • Motion detection, Tampering, Defocus detection • Hallway view (90°/270°), LDC support • Micro SD/SDHC/SDXC memory slot (Max. 128GB) • IR viewable length 20m • IP66, IK10, PoE, 12VDC Hanwha QNV-6082R/Avigilon/Mobotix
2 Supply, installation, testing and commissioning of Bullet Camera -ANPR with required pole. • Max. 2megapixel (1920 x 1080) resolution • 0.03lux (Color), 0Lux (B/W, IR LED on) • 3.2 ~ 10mm (3.1x) motorized varifocal lens • Max. 30fps@2M all resolutions (H.265/H.264) • H.265, H.264, MJPEG codec supported, Multiple streaming • Motion detection, Tampering, Defocus detection • Hallway view (90°/270°), LDC support • Micro SD/SDHC/SDXC memory slot (Max. 128GB) • IR viewable length 30m • IP66, IK10, PoE/12VDC Hanwha QNO-6082R/Avigilon/bosch
3 Supply, installation, testing and commissioning of PTZ Camera • Max. 2MP resolution • 4.25~170mm (40x) zoom (digital 32x, total 1280x zoom) • Max. IR viewable length 200m (656.17ft), Wise IR • Day & Night (ICR), extreme WDR, DIS(Built-in gyro sensor) • Intelligent analytics, Object auto tracking (Person/Vehicle), Target lock tracking • H.264, H.265, MJPEG codec, WiseStream II • IP66, IK10, NEMA4X, NEMA-TS 2 (2.2.8, 2.2.9) • PTZ PLUS Design applied (Compact, Lighter, Simple cabling) • SFP-supported by injector Hanwha XNP-6400R SBP-156WMW/hikvision/Trueview
4 Supply, installation, testing and commissioning of ANPR Video Analytics Allgovison/Digitpol/Vaxtor
5 Supply, installation, testing and commissioning of ANPR workstation with minimun specs recommended by OEM. Dell/Hp
5.1 Supply, installation, testing and commissioning of 55" Monitor with minimun specs. LG LG UQ90 55/ Samsung/Dell
6 Supply, Installation, Testing & Commissioning of Video management software. The VMS application must have native capability to scale into a full fetched Command & Control platform and capability to provide incident management features like Rule engine, SOP ‘s and Incident reports with no dependency on any external 3rd party software. Security Center Base software, with Primary Directory software license & 1 failover directory license. The proposed VMS platform must be UL 2900-2-3 Level 3 Cybersecurity certification Genetec GSC-5.11+ GSC-OM-C+ /Avigilon/Mobotix
7 Supply, installation, testing and commissioning of Camera License for working & failover connection. The Proposed Solution shall support native Fail over with in application with no dependency on any external application for both hardware and application redundancy. The native fail over architecture must be for both management and recording servers. Video Management System should support End to End Multicast (i.e Clients should be able to view the video Footages Directly from the Multicast stream of the Cameras) with 5 years support Genetec GSC-OM-C-1C + SUP-CAM-C-5Y/Avigilon/Mobotix
8 Supply, installation, testing and commissioning of All in one Video recording server with 48TB RAW storage 43 TB Usable Dell OptiPlex T4: Dell Precision 3650 XE 1x 256 GB SSD (1) 1GBE RJ45 (1GbE port standard, option for 2x 1Gbe ports) (Display Connections: 2x DisplayPort). Recording parameters at 25 FPS @1080P for 30 Days Genetec SV-300E-T4-48T-16-I/Avigilon/Mobotix
9 Supply, installation, testing & commissioning of 24 Port PoE+ Switch with 2 SFP slots Dlink/havells/AMP
10 Supply, installation, testing & commissioning of L2 managed 08-Port POE enabled 10/100/1000BASE-T switch with 2 SFP ports module populated Dlink/havells/AMP
11 Supply, installation, testing & commissioning of 15 U Network Rack Dlink/havells/AMP
12 Supply, installation, testing & commissioning of 6 U Network Rack Dlink/havells/AMP
13 Supply, installation, testing & commissioning of 12 Port LIU Dlink/havells/AMP
14 Supply, installation, testing & commissioning of 24 port cat 6 UTP fully loaded patch panel Dlink/havells/AMP
15 Supply, installation, testing & commissioning of Cat-6 IO Dlink/havells/AMP
16 Supply, installation, testing & commissioning of 6 core OFC outdoor armoured cable Dlink/havells/AMP
17 OFC SM duplex patch chord 2m (SC-LC) Dlink/havells/AMP
18 Supply, installation, testing & commissioning of OFC SM duplex patch chord 2m (SC-LC) Dlink/havells/AMP
19 Supply, installation, testing & commissioning of cat 6 UTP Patch chord -1m Dlink/havells/AMP
20 Supply, installation, testing & commissioning of cat 6 UTP Patch chord -2m Dlink/havells/AMP
21 Supply, installation, testing & commissioning of cat 6 UTP cable Dlink/havells/AMP
22 Supply, installation, testing & commissioning of 20mm PVC Conduit VIP/Gemini/Techno flex
23 Supply, installation, testing & commissioning of 3 Meter Pole with required Civil Works
24 Excavation & refilling of soft soil
25 HDPE Pipe 50 mm
1 Supply and Installation of Pure IP Hardware Plat from for Unified Communication Server, 19" Rack Mount with 1U Enclosure The 50 IP Extensions expandable up to 100 IP Extensions (License software from Day1) Pure IP communication system should be configured for: 1- no’s of Operator console IP based with each operator console 16 Keys Direct Station Selection(DSS) 4 - no’s of PSTN trunk port 1 - no’s of PRI port (ISDN & SIP compatible) 50 - no’s of IP user license 100% non- blocking architecture Matrix/Eternity/panasonic
2 IP phone and Operator console with POE, IP/DSS Console with 32 special keysmust be same as per OEM of IP-PBX. • VoIP Protocol: Proprietary • Ethernet Ports: 2 (PC and LAN) • Display: 240 x 64 Pixels Graphical LCD with Backlit • Color: Black • Programmable Keys: 4 Context Sensitive Keys, 16 DSS Keys • Power Supply: PoE SPARSH VP510E +DSS532 /Coral/Kntech
3 Entry-level Gigabit IP PhoneStandard SIP Phone with PoE • Ethernet Ports: 2 (Gigabit ports - PC and LAN) • Display: 128 x 64 Pixels Graphical LCD (3.1 Inch) • Color: Black • Functional Keys:3 Feature Keys, 4 Context Sensitive Keys, 2 Line Keys, Volume Control Keys SPARSH VP210 /Coral/Kntech
4 Supply, installation, testing & commissioning of 24 U Network Rack NRS1-24U/Elixir/Vtech
5 Testing and commissiong
ELECTRICAL FENCHING
1 Supply of Gallagher 6000 Network controller with Command Center Software along with necessary cabling, accessories Etc complete in all respects GALLAGHER/polycab/RR
2 Supply of F42 fence controller with appropriate outdoor weatherproof enclosures, necessary cabling, accessories Etc complete in all respects GALLAGHER/polycab/RR
3 Supply of Fence hardware consisting Hot Dip Galvanized Kiwitah Posts, Hot Dip Galvanized 50NB MS pipe with 32NB pipe for stay support, UV Stabilized insulators, Wire Tightners, Earth System, Warning Sign Boards and Etc accessories
4 Installation, testing, commissioning, auditing and training to the Security and Maintenance staff
PARKING MANAGEMENT SYSTEM
1 Supply, testing and commissioning of parking management software (Annual Recurring)- Cloud Portal Bosch/Idtech/Vyapar
2 Supply, testing and commissioning of Mobile app charges (per user per year) Bosch/Srtech/Idtech
3 Supply, testing and commissioning of 3rd party integration charges (one time) Bosch/Idtech/Vyapar
4 Supply, testing and commissioning of Slot Sensor Bosch/matrix/Billwire
5 Supply, testing and commissioning of Display panasonic/LG/Samsung
6 Supply, testing and commissioning of Access controller for gate Bosch/Avigilon/Magnetic
7 Supply, testing and commissioning of 3mtr Boom Barrier Magnetics/Idtech/Avigilon
8 Supply, testing and commissioning of Push Button SCZ/IPTEB- 33SS (Ebelco)
9 i7 Machine with Latest Processor, 8GB RAM 1GB Graphics Card Built in DVD R/W drive 1 TB HDD Keyboard, Mouse, Windows/Linux Latest OS 24'' inch display Dell/HP/lenovo
10 Supply, Fixing and Laying of 3 Core 1.5 Sq shielded mm copper, armoured Cable Varsha/Extron/polycab
11 Supply, Fixing and Laying of 2 Core 1.5 Sq shielded mm copper, armoured Cable Varsha/Extron/polycab
VIDEO CONFERENCE SYSTEM
1 Video Conference : Video Conferencing Equipment for 7 party (1080P) conferencing with 12x Camera Avaya / Polycom/hikvision
2 65" Standard LED display for video conference system with wall mounting bracket
3 Supply, Installation, testing and commissioning of 240 W Mixer amplifier Bosch PLE-1ME240-3IN /Ahuja/JBL
4 Supply, Installation, testing and commissioning of 6 W wall mounted speaker 100 V line for indoor application Bosch LBD3902-L /Ahuja/ honeywell
5 Supply, Installation, testing and commissioning of Digital Discussion System and have miniumum 80 discussion and expandable upto 245 devices, the control unit shall have MP3 recording and Digital Acoustic Feedback Suppression . Bosch / CCSD-CURD/ Shure DDS 5900
6 Supply, Installation, testing and commissioning of Digital Discussion System Extension unit and shall be expandable upto 245 devices, Single Extension Unit can provide power for up to 85 additional Discussion and One trunk and two tap‑off connections with short‑circuit protection Bosch / CCSD-CURD/ Shure DDS 5901
7 Supply, Installation, testing and commissioning of Discussion device with long Microphone with Plug and play functionality for ensuring fast installation and reconfiguration times, the microphone shall have the following features, Request‑to‑speak indication, Microphone with flexible stem, Built-in loudspeaker with volume control, Face-to-face meeting feeling and Headphones socket Bosch / CCSD-CURD/ Shure DDS 5902
8 Supply, Installation, testing and commissioning of Extension Cables with Low smoke zero halogen to comply with safety and environmental standards. Bosch / LBB 4116/25/Extron
9 Supply and Fixing of 24U rack for install all AV equipment etc. complete.
10 Supply and laying of HDMI & VGA Wall plate.
11 Supply and laying of 10Mtr HDMI Cable.
12 Supply and laying of 5Mtr HDMI Patch Cable.
13 Supply and laying of 5Mtr VGA Patch Cable.
14 Supply and laying of 2 core * 0.75 sq mm speaker cable
15 Supply, Fixing and Laying of 20 MM PVC Conduit
ACCESS CONTROL SYSTEM
1 Supply, Installation, testing and commissioning of Surface mounted Networkable multiprocessor controlled 4 reader controller capable of controlling multiple readers (IN/OUT) alongwith TCP/IP connectivity complete as per specifications. Control panel housed in MS Powder Coated Cabinet with Tamper Switch, Complete with power supply unit for Controllers & Magnetic Locks as per specification Bosch APC-AMC2-4WCF / Honeywell/Simatic
2 Supply, installation, testing and commissioning of Access Control Application Software for 128 Reader Capacity, and 1000 Card Holder Capacity, BIS-XACE-128D49/Dahua/Rosslare
2.1 Supply, installation, testing and commissioning of Time & attendance software . BIS-XACE-128D49/Dahua/Rosslare
3 SITC of Client workstation with 21" Monitor for Access Control System & Time & attendance system Dell/panasonic/LG
4 Supply, Installation, Testing & Commissioning of Biometric + Card reader Suprema / Idemia/HID
5 Supply, installation, testing and commissioning of UL Listed Smart Card Reader with compatible support of weigand output, 13.56 MHz technology platform and complies with the ISO 15693 / 14443A standard for contact less smart card technology. Card reader must be configurable to read encrypted ISO14443A sectors using standard or custom read keys for Sign OUT Terminal. should be compatible with HID format cards. Encryption,All RF data transmission between the card and reader should be encrypted using a secure algorithm. Industry- standard encryption techniques and advanced key management systems should be used to avoid the risk of compromised data or duplicated cards. The reader should have audio transducer to provide various tone sequences to signify access granted, access denied, power up and diagnostics. Visually impaired cardholders can easily distinguish between access granted and access denied. High-intensity light bar should provide a clear visual status indication in red, green or amber, even in bright sunlight. HID R10 / Idtech/Avigilon
6 Supply, testing and commissioning of iClass Smart card. HID I class16k /Idtech
7 Supply, installation, testing and commissioning of Double Leaf Electro Magnetic Lock of Suitable Capacity(Min 600+600 lbs). BEL/600D-LED Double/Magnetic
8 Supply and Fixing of ''U'' Bracket with Accessories.
9 Supply, Fixing and Laying of 8 Core 1 Sq mm copper, unarmoured Cable (between the every readers & the access controllers). Varsha/polycab/RR
10 Supply, Fixing and Laying of 4 Core 1 Sq mm copper, unarmoured Cable Varsha/polycab/RR
11 Supply, testing and commissioning of Panic Bar Dorma PHW - DOR/PHCR-1000-1 Point
12 Supply, testing and commissioning of LSA SCHUTZ LSA - SCZ/ILSA-230AC Local
13 Supply, Fixing and Laying of 20 MM PVC Conduit VIP/Gemini/Techno flex
ADDITIONAL SECURITY SYSTEM
1 Supply, Installation, Testing & Commissioning of 8 Zone Door Frame Metal Detector with all required accessories. uPMD-008(Sivananda Electronics) / ESSL/SISS
2 Supply, Installation, Testing & Commissioning of Handheld Metal Detector. NP-SH100 (HIKIVISON)/ ESSL/SISS
3 Supply, Installation, Testing & Commissioning of X-Ray Baggage Scanner with all required monitoring station, Hardware & Accessories.
i Tunnel Size- 500 MM X 300 MM ( FOR MAIL & HANDBAG ) KV5030-Krystalvision/ESSL/ALFA
ii Tunnel Size- 650 MM X 350 MM (FOR BAGGAGE) KV5030-Krystalvision/ESSL/ALFA
4 Supply, Installation, Testing & Commissioning of Female Frisking with all required accessories.
CCTV Approved Makes
1 Cameras Bosch/Avigilon/Mobotix
2 Servers Genetec/Avigilon/Mobotix
3 PC/Workstation DELL / HP/Acer
4 HD monitor Panasonic/Samsung/Sony
5 HDMI cable Logic/Extron/Cadyce
6 Rack Netrack/Universal/Riial
7 Patch chord AMP/Schneider/Panduit
8 PoE+ Cisco/Novotech/crista
9 Patch panel AMP/Schneider/Panduit
10 Industrail grade 1 port media converter Hirschmann/as approved
11 Armoured power cable Varsha/Polycab/RR
Enter basic data here
[Fill up data only in the relevent open area]
1 Name of Package Construction of a Control Centre Building for OPTCL STAMS (State Transmission Asset Management System) Project by POWERGRID under Consultancy Services to OPTCL
2 Specification No. ODP/BB/C&M-3575/OT-24/RFx No. 5002003243/23-24
4 Item Description Light Weight T&P
5 Quantity in km.
6 Type Tests Tests to be conducted Nos of tests
(a) UTS test on stranded conductor 1
(b) DC resistance test on stranded conductor 1
(c) Corona extinction voltage test on hex bundle (dry) 1
(d) Radio interference voltage test on hex bundle (dry) 1
Construction of a Control Centre Building for OPTCL STAMS (State Transmission Asset Management System) Project by POWERGRID under Consultancy Services to OPTCL
Specification No.: ODP/BB/C&M-3575/OT-24/RFx No. 5002003243/23-24
1 Fill up only green shaded cells in Sch-1A to Sch-1O
2 All the cells in Sch-2 & 3 are auto filled, therefore no cell is required to be filled up there.
3 Instructions / error messages, if any, will be displayed automatically after selecting the cell.
4 Based on the data filled in the respective schedules, e-Form is generated automatically. A print out of e-Form may be taken and the data may be filled in the electronic form of the tender provided on the portal.
I While filling up the worksheets following may please be observed :
(i) Fill up only green shaded cells.
(ii) Certain data type entries have been restricted, such as Numeric values or limits of numeric values.
(iii) Select only the options provided in pull down menus.
(iv) Do not link any cell of this work book with any other work book.
(v) Do not use copy & paste or cut & paste options for filling up the data.
(vi) Do not reformat any of the cell of the work book.
II This Workbook consists of following worksheets :
Opening page of the workbook.
Names of Bidder :
● Select Sole Bidder or JV (Joint Venture) from the pull down menu. Do not leave this cell blank.
● Select nos. of the JV Partners other than the Lead Partner from drop down menu.
● In case of JV partners more than 2, enter details of 3rd & more partners along with details of 2nd partner.
● Fill up names and address of the Bidder
● Fill up date in dd-mm-yyyy format from drop down menu.
● Click for Sch-1 given at the right top of the worksheet to go to Sch-1.
● Column 6 (HSN/SAC code): If HSN/SAC code provided in Column 6 (for the Item Description in Column 3) is same as Bidder's HSN/SAC code, write "Confirm". If Bidder wants to provide a different HSN/SAC code, please write the code. If left blank, it shall be treated as confirmation of HSN/SAC code provided in Column 6.
● Column 8: Select options "Same as Column 7" or "NIL" or "Different GST rate in Column 9" from drop-down menu as per details given below. If this column is left blank, GST calculation will be done based on Column 7 (provided by Employer).
"Same as Column 7" : If you confirm GST rate provided in Column 7, select this option.
"NIL": If you are exempted from GST or GST is not applicable for that item, select this option.
"Different GST rate in Column 9" : If you are providing GST rate different from that provided in Column 7, select this option.
● Column 9 (GST rate): If you have selection option "Different GST rate in Column 9" in Column 8, type the GST rate applicable for you. However, if this column is left blank even after selecting option "Different GST rate in Column 9" in Column 8, GST calculation will be done based on Column 7 (provided by Employer).
● Fill up unit rates for all the items in numeric values greater than 0 (zero). If unit rate is left blank, the corresponding item shall be deemed to be included in the total price.
● Unit rates of the items shall be inclusive of all duties, levies, cess etc. excluding GST. GST shall be applicable on transaction between Employer and Contractor. Employer will not pay any GST on transaction between Contractor and sub-vendors.
● Total amount shall get calculated automatically.
Sch -2 : Summary of Taxes and Duties
● Summary of GST quoted on all items in Schedule 1 shall be displayed automatically.
● No cell is required to be filled in by the bidder in this worksheet.
Sch -3 : Grand Summary
● Total amount including GST, taxes, duties etc. shall be calculated and dislayed automatically.
● No cell is required to be filled in by the bidder in this worksheet.
Bid from 2nd Envelope :
● Fill up ref. no. as bidder's ref no. of this letter.
● This letter shall consider the total price as per Grand Summary (Schedule-3).
● Fill up names & Designation of the representatives of other JV partner(s) if the bidder is JV (Joint Venture) .
● Fill up additional information as required.
● Fill up ref. no. as bidder's ref no. of this letter.
● This letter shall consider the total price as per Grand Summary (Schedule-5).
● Fill up additional information as required.
Happy Bidding !
Construction of a Control Centre Building for OPTCL STAMS (State Transmission Asset Management System) Project by POWERGRID under Consultancy Services to OPTCL
Specification No.: ODP/BB/C&M-3575/OT-24/RFx No. 5002003243/23-24 Sole Bidder Orignal Equipment Manufacturer
Authorised Dealer of Manufacturer
Enter following details of the bidder Authorised Distributor of Manufacturer
Authorised Indian Representative of Manufacturer
Specify type of Bidder [Select from drop down menu] #REF!
Whether the bidder is an MSE (Micro & Small Enterprise)
E-mail Id of Bid Signatory
Mobile no. Bid Signatory
Tel. no. of Bid Signatory
Specification No.: ODP/BB/C&M-3575/OT-24/RFx No. 5002003243/23-24 Schedule - 1
Construction of a Control Centre Building for OPTCL STAMS (State Transmission Asset Management System) Project by POWERGRID under Consultancy Services to OPTCL
(SCHEDULE OF RATES AND PRICES : EX-WORKS PRICES)
Bidder’s Name and Address To:
Bidder as Contract Services
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 "Saudamini", Plot No.-2
0 Sector-29, (near IFFCO Chowk)
0 Gurgaon (Haryana) - 122001
Plant and Equipment (including Mandatory Spares Parts) to be supplied, including Type Test Charges for Tests to be conducted.
All values are in Indian Rupees.
SI. No. Item Description Type & Designation Unit Qty. Unit Ex-works price Total Ex-works price Mode of Transaction (Direct / Bought-out)
#REF! #REF! #REF! #REF! #REF! #REF! #REF! #REF! #REF!
Total Ex-Works Price 0.00 Direct
Total Ex-Works Price 0.00 Bought Out
Total Ex-Works Price 0.00
Total Type Test charges as per Schedule-6 #REF!
Total Ex-works Price including Type Test charges #REF!
Note : Specify amount of Excise Duty, Sales Tax/VAT and other taxes payable on the transaction between the Contractor and the Employer and octroi/entry tax as applicable for destination site/state on all items of supply including bought-out finished items (to be identified in the Contract), which shall be dispatched directly from the sub-vendor’s works to the Employer’s site (sale-in-transit), separately in Schedule-5. Excise Duty, Sales tax and other levies for all the bought-out items are to be included in the EXW Price (Col. No. 5) only and not to be indicated in Schedule-5.
Date : 00/Jan/00 Signature :
Place : 00/Jan/00 Printed Name : 0
Designation : 0
Specification No.: ODP/BB/C&M-3575/OT-24/RFx No. 5002003243/23-24 Schedule - 2
Construction of a Control Centre Building for OPTCL STAMS (State Transmission Asset Management System) Project by POWERGRID under Consultancy Services to OPTCL
(SCHEDULE OF RATES AND PRICES : FREIGHT & INSURANCE CHARGES)
#REF! Contract Services
Name : #REF! Power Grid Corporation of India Ltd.,
Address : #REF! "Saudamini", Plot No.-2
#REF! Sector-29, (near IFFCO Chowk)
#REF! Gurgaon (Haryana) - 122001
All values are in Indian Rupees.
SI. No. Item Description Type & Designation Unit Qty. Unit price Total Ex-works price
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! Total Freight & Insurance #REF!
Date : #REF! Signature :
Place : #REF! Printed Name : #REF!
Designation : #REF!
Specification No.: ODP/BB/C&M-3575/OT-24/RFx No. 5002003243/23-24 Schedule - 1A (Civil Works)
Construction of a Control Centre Building for OPTCL STAMS (State Transmission Asset Management System) Project by POWERGRID under Consultancy Services to OPTCL As per Lum-sum
(SCHEDULE OF RATES AND PRICES ) AS per Percent
As per lum-sum on Sch-3
Bidder’s Name and Address To: As per Percent on Sch-3
#REF! Sr. GM(C&M) Multipackage lum-sum
Name: POWER GRID CORPORATION OF INDIA LIMITED, Multipackage on Percent
Address: ODISHA PROJECTS Total Discount
PLOT NO.-4, UNIT-41, NILADRI VIHAR
CHANDRASHEKHARPUR, BHUBANESWAR-751021
CIVIL WORKS All Prices are in Indian Rupees.
SI. No. Service Activity Number DSR 2023 Item Description Unit Qty. SAC/HSN Codes Whether SAC/HSN in column ‘4’ is confirmed. If not indicate applicable the SAC/HSN # Rate of GST applicable ( in %) Select from Drop-down menu. Whether rate of GST in column ‘6’ is confirmed. If not indicate applicable rate of GST # Unit Rate (excluding GST) but including labour welfare cess & Freight (if any) GST Amount Amount (Excluding GST) but including labour welfare cess & freight (if any) Unit Erection Charges Total Erection Charges
1 120000394 2.1.1 Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge: .(REF : CPWD DSR 2023,Vol-1, page no-87 ,Item no. 2.1) sqm 1889.160 995433 Confirmed 18 Confirmed 0.00 0.01 Cum 1080 1080 995433 18.00
2 2.8.1 Earth work in excavation by mechanical means (Hydraulic excavator)/ Manual means in all types of soil in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50m.a) Lift upto 1.5 mtr.(REF : CPWD DSR 2023,Vol-1, page no-74 ,Item no. 2.8) cum 3379.254 995433 Confirmed 18 Confirmed 0.00 0.01
3 2.26.1 Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. All kinds of soil (REF : CPWD DSR 2023,Vol-1, page no-95 ,Item no. 2.26) cum 2833.740 995433 Confirmed 18 Confirmed 0.00 0.01
4 2.27 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. (REF : CPWD DSR 2023,Vol-1, page no-77,Item no. 2.27) cum 1133.167 995433 Confirmed 18 Confirmed 0.00 0.01
5 4.20.1.1 Providing and laying in position ready mixed or site batched design mix cement concrete for plain cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana/Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS:9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering and finishing as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the minimum specified cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. Concrete of M10 grade with minimum cement content of 220 kg /cum (REF : CPWD DSR 2023,Vol-1, page no-105 ,Item no. 4.20.1.1) cum 360.624 995454 Confirmed 18 Confirmed 0.00 0.01
6 4.17 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size) over75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth sqm 28.875 995454 Confirmed 18 Confirmed 0.00 0.01
7 6.1.1(M) Brick work with fly ash (non modular) bricks conforming to IS:12894 of class designation 10 in foundation and plinth in:Cement mortar 1:4 (1 cement : 4 coarse sand) cum 190.335 995456 Confirmed 18 Confirmed 0.00 0.01
8 6.34.2 Brick work with non modular fly ash bricks conforming to IS:12894, class designation 10 average compressive strength in super structure above plinth level up to floor V level in:Cement mortar 1:6 (1 cement : 6 coarse sand) cum 1336.020 995456 Confirmed 18 Confirmed 0.00 0.01
9 6.45.1 Half brick masonry with non modular fly ash bricks of class designation 10, conformingio IS :12894, in super structure above plinth and upto floor V level. sqm 74.054 995456 Confirmed 18 Confirmed 0.00 0.01
10 6.15 Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry. sqm 74.054 995433 Confirmed 18 Confirmed 0.00 0.01
11 5.33.1.2 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. All works upto plinth level: Concrete of M30 grade with minimum cement content of 350 kg /cum Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. (Ref. No. : CPWD DSR 2023,Vol-1, page no-120, ,Item no. 5.33.1.2) cum 1701.867 995454 Confirmed 18 Confirmed 0.00 0.01
12 5.33.2.2 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. All works above plinth level upto floor V level: Concrete of M30 grade with minimum cement content of 350 kg /cum Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. cum 433.253 995454 Confirmed 18 Confirmed 0.00 0.01
13 5.33.2.3 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. All works above plinth level upto floor V level: Concrete of M35 grade with minimum cement content of 370 kg /cum Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.(Ref. No. : CPWD DSR 2023,Vol-1, page no-120, ,Item no. 5.33.2.3) cum 2534.168 995454 Confirmed 18 Confirmed 0.00 0.01
13A 5.35 Add for using extra cement in the items of design mix over and above the specified cement content therein. quintal 1684.934 995454 Confirmed 18 Confirmed 0.00 0.01
14 5.9.1 Centering and shuttering including strutting, propping etc. and removal of form for: Foundations, footings, bases of columns, etc. for mass concrete (Ref. No. : CPWD DSR 2023,Vol- 1, Item no. 5.9) sqm 206.732 995457 Confirmed 18 Confirmed 0.00 0.01
15 5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts SQM 1820.250 995457 Confirmed 18 Confirmed 0.00 0.01
16 5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers SQM 2038.630 995457 Confirmed 18 Confirmed 0.00 0.01
17 5.9.19 Weather shade, Chajjas, corbels etc., including edges SQM 53.730 995457 Confirmed 18 Confirmed 0.00 0.01
18 5.9.2 Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. SQM 2283.956 995457 Confirmed 18 Confirmed 0.00 0.01
19 5.9.7 Stairs, (excluding landings) except spiral-staircases SQM 432.350 995457 Confirmed 18 Confirmed 0.00 0.01
20 5.9.3 Suspended floors, roofs, landings, balconies and access platform SQM 7258.980 995457 Confirmed 18 Confirmed 0.00 0.01
21 5.22.6/5.22A.6 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level and above plinth level (Ref. No. : CPWD DSR 2023,Vol-2, page no-118, ,Item no.5.22.6) KG 234863.000 995454 Confirmed 18 Confirmed 0.00 0.01
22 13.3.2 Providing and applying 20 mm cement plaster of mix :1:6 (1 cement: 6 Fine sand) on External surfaces of walls (brick or concrete surfaces) finished smooth with trowel including scaffolding, curing etc., complete at all heights. (Ref. No. : CPWD DSR 2023,Vol-2, page no-258, ,Item no.13.3.2) SQM 3564.495 995472 Confirmed 18 Confirmed 0.00 0.01
23 13.1.2 Providing and applying 12 mm cement plaster of mix :1:6 (1 cement: 6 Fine sand) on internal surfaces of walls (brick or concrete surfaces) finished smooth with trowel including scaffolding, curing etc., complete at all heights. (Ref. No. : CPWD DSR 2023,Vol-2, page no-258, ,Item no.13.1.2) SQM 7496.623 995472 Confirmed 18 Confirmed 0.00 0.01
24 13.16.1 Providing and applying 6 mm cement plaster of mix :1:3 (1 cement : 3 fine sand) on the all concrete surfaces of columns, beams and slabs finished smooth and even.(Ref. No. : CPWD DSR 2023,Vol-2, page no-259, ,Item no.13.16.1) SQM 6350.713 995472 Confirmed 18 Confirmed 0.00 0.01
25 13.8 Providing and applying white cement based putty of average thickness 1 mm, of Birla white or equivalent approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete,(Ref. No. : CPWD DSR 2023,Vol-2, page no-266, ,Item no.13.80) SQM 13273.216 995472 Confirmed 18 Confirmed 0.00 0.01
26 13.85.3 Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content.,(Ref. No. : CPWD DSR 2023,Vol-2, ,page no 266, Item no.13.85.3) SQM 13273.216 995473 Confirmed 18 Confirmed 0.00 0.01
27 13.60.1 Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade . (Ref. No. : CPWD DSR 2023,Vol-2, page no-264, ,Item no.13.60.1 SQM 13273.216 995473 Confirmed 18 Confirmed 0.00 0.01
28 13.46.1 Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm).(Ref. No. : CPWD DSR 2023,Vol-2,page no 262 ,Item no.13.46.1) SQM 3564.495 995473 Confirmed 18 Confirmed 0.00 0.01
29 13.18 Neat Cement Punning. (Ref. No. : CPWD DSR 2023,Vol-2, page no-259, ,Item no.13.18) SQM 183.360 995472 Confirmed 18 Confirmed 0.00 0.01
30 11.26.1 + 8.6 Providing and laying Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :25 mm thick with Mirror polishing to give high gloss finish complete. (Ref. No. : CPWD DSR 2023,Vol-1, page no- 221,145 Item no.11.26.1, 8.6) SQM 288.510 995474 Confirmed 18 Confirmed 0.00 0.01
31 11.27 + 8.6 Kota stone slabs 20 mm thick in risers of steps, skirting, dado andpillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.(Ref. No. : CPWD DSR 2023,Vol-1, page no-221,145 Item no.11.27, 8.6) SQM 31.632 995474 Confirmed 18 Confirmed 0.00 0.01
32 11.21.1.1 Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approved make and colour using acid and/or alkali resisting mortar bedding, and joints filled with acid and/or alkali resisting cement as per IS : 4457, complete as per the direction of Engineer-in- Charge.(In flooring on a bed of 10 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand)). (Ref. No. : CPWD DSR 2023,Vol-1, Item no.11.21.1) SQM 276.270 995474 Confirmed 18 Confirmed 0.00 0.01
33 11.21.2.1 Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approved make and colour using acid and/or alkali resisting mortar bedding, and joints filled with acid and/or alkali resisting cement as per IS : 4457, complete as per the direction of Engineer-in- Charge.(In dado/skirting on 12 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand)). (Ref. No. : CPWD DSR 2023,Vol-1, Item no.11.21.2.1) SQM 19.660 995474 Confirmed 18 Confirmed 0.00 0.01
34 11.41A.2.5 Providing and laying vitrified floor tiles polished finish of size 1200X1200 in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.. (Ref. No. : CPWD DSR 2023,Vol-1, Item no.11.41A.2.5) SQM 4693.050 995474 Confirmed 18 Confirmed 0.00 0.01
35 11.41A.3.1 Providing and laying Glazed Vitrified tiles Matt/Antiskid finish of size 600x600 in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.. (Ref. No. : CPWD DSR 2023,Vol-1, page no- 224 Item no.11.41A.3) SQM 137.580 995474 Confirmed 18 Confirmed 0.00 0.01
36 11.46.2 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. (Ref. No. : CPWD DSR 2023,Vol-1, page no- 224 Item no.11.46.2) SQM 1137.520 995474 Confirmed 18 Confirmed 0.00 0.01
37 8.31 Providing and fixing Ist quality ceramic glazed wall tiles conforming toIS: 15622 (thickness to be specified by the manufacturer), of approvedmake, in all colours, shades except burgundy, bottle green, black ofany size as approved by Engineer-in-Charge, in skirting, risers of stepsand dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm,including pointing in white cement mixed with pigment of matching shadecomplete.(Ref. No. : CPWD DSR 2023,Vol-1, page no-162 Item no.8.31) SQM 574.120 995474 Confirmed 18 Confirmed 0.00 0.01
38 11.56.1 Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.(Ref. No. : CPWD DSR 2023,Vol-1, page no-228 Item no.11.56.1) SQM 368.640 995475 Confirmed 18 Confirmed 0.00 0.01
39 9.48.1 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.fixed to openings with rawl plugs and necessary screw etc.as per direction of E- I-C.(Ref. No. : CPWD DSR 2023,Vol-1, page no-174 Item no.9.48.1) KG 6553.500 995475 Confirmed 18 Confirmed 0.00 0.01
40 13.50.3 Providing and applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works. (Ref. No. : CPWD DSR 2023,Vol-2, page 263, Item no.13.50.3) SQM 218.450 995473 Confirmed 18 Confirmed 0.00 0.01
41 13.62.1 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade Two or more coats on iron work (Ref. No. : CPWD DSR 2023,Vol-2, page 264, Item no.13.62.1) SQM 492.680 995473 Confirmed 18 Confirmed 0.00 0.01
42 9.136 Providing and fixing fire resistant door frame of section 143 x 57 mm having built in rebate made out of 16 SWG G.I. sheet (zinc coating not less than 120 gm/sqm) duly filled with vermuculite based concrete mix, suitable for mounting 60 minutes fire rated door shutters. The frame is fitted with intumuscent fire seal strip of size 10x4 mm (minimum) alround the frame and fixing with dash fastener of approved size and make, including applying a coat of approved brand fire resistant primer etc. complete as per direction of Engineer-in-charge (Dash fastener to be paid for separately).: CPWD DSR 2023,Vol-1, Item no.9.136) RMT 166.800 995476 Confirmed 18 Confirmed 0.00 0.01
43 26.87.1 Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance. (30 mm. Thick)(Ref. No. : CPWD DSR 2023,Vol-2, Item no.26.87) SQM 274.680 995476 Confirmed 18 Confirmed 0.00 0.01
44 25.2 Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including:.(Ref. No. : CPWD DSR 2023,Vol-2, Item no.25.2) SQM 572.980 995471 Confirmed 18 Confirmed 0.00 0.01
45 NDSR Supply and installation of tested Vetrotech Saint-Gobain VDS® fully glazed fire-rated unlatched double leaf door system with 120 minutes of integrity and radiation control (EW 120) with symmetrical (bi- directional) fire protection through a VDS Certified Installer. The frames shall be made of imported cold rolled profiles. The door frames are cold rolled from 1.5 mm steel sheet to form a profile of 50 mm x 50 mm on all sides. The door shutter would have the top rail, side rail and bottom rail dimensions of 50 mm x 50 mm. The overall door opening shall be as per tested evidence and tested as per EN 1634-1 in an accredited international laboratory. The glass shall be CONTRAFLAM LITE (14mm) clear, non-wired, toughened, interlayered, 120 minutes fire-rated glass for integrity and radiation control (EW 120) and insulation (I 20) with a light transmission of 86% and a sound reduction of 38 dB and manufactured in UL & TUV audited facility and including UL-EU Certification (File number R38101) and compliant to class 1(B)1 category of Impact Resistance as per EN 12600. The glass shall be tested for 5000 hours of UV resistance as per EN ISO 12543-4. The glass shall be EPD (Environmental Production Declaration) verified in accordance to EN 15804 and ISO 14025 in which its life cycle assessment is performed considering Cradle to Gate system boundaries. The glass must produce a recycled content declaration committing to a pre- consumer cullet of up to 11% and post-consumer cullet less than 1%. The glass shall provide bi- directional (symmetrical) fire protection. The shutters should be fixed to the frame using weld-on hinges of dimensions 179mm X 20mm. The profiles shall have grooves to incorporate fire-resistant gaskets. The doors shall incorporate drop down seal at the bottom. The glass should be held in its place with the help of 1.5 mm cold rolled steel beading and Kerafix 2000 ceramic tape with cross section of 4 x 15 mm as per the test evidence. The beading shall be clipped on using stainless steel self-tapping screws fixed at 70 mm from the edges and 150 mm c/c henceforth. The glass panes are to be supported on non-combustible 5 mm thick calcium silicate setting blocks. The door should be fitted with two point latch lock system including a pair of stainless steel lever handle, a pair of stainless steel rosette and top shoot bolt system as per the test evidence. The door shall have a door closer of Dorma (TS 73V, TS 83V, TS93V), Geze (TS 2000NV) or equivalent. The inactive leaf should be fixed to the frame using a tower bolt at meeting edge at top and bottom or as per the tested evidence. The doors shall be manufactured in a TUV audited facility. The installation of the door shall be through a VDS certified Installer who is trained and certified by Vetrotech Saint-Gobain. The installer shall have an active VDS Certified Installer certificate from Vetrotech Saint-Gobain. The doors shall offer C4 level of wind resistance when tested as per EN12211 and shall provide class 4 level of air permeability as per EN 1026. The door shall also be subjected to durability tests as per EN 12400 for C5 classification (200,000 cycles). The doors shall also be tested for class 5 of impact resistance when tested as per EN 13049. The doors shall also be tested for class 4 level of mechanical strength when tested as per EN13115. The doors shall have water tightness level of 8A when tested as per EN 1027. Test evidence: The test report will be considered valid only if it contains the stamp and signature of the authorized signatory from Vetrotech Saint-Gobain. NOS 8.000 995476 Confirmed 18 Confirmed 0.00 0.01
46 9.147(D-3) Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon-(Two track two panels sliding window made of (big series) frame 67 x 50 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension.)(CPWD DSR 2023,Vol-1, Item no.9.147(D-3) SQM 118.350 995476 Confirmed 18 Confirmed 0.00 0.01
47 22.6 Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound of reputed make like consisting of applying a)after surface preparation, first layer of slurry of cement mixed with water proofing cement compound as per manufacturer specification b)Laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. c)third layer of 1.5 mm thickness consisting of slurry of cement mixed with water proofing cement compound as per manufacture specification. This will be allowed to air cure for 4 hours followed by water curing for 48hours. d)fourth and final layer is 25mm thick protective screed to be laid in panels by providing Chicken wire mesh. For the purpose of measurement, the entire horizontal surface area will be measured. The product performance shall carry guarantee for 10 years against any leakage(Ref. No. : CPWD DSR 2023,Vol-2, Page no, 435,Item no.22.6) SQM 4369.560 995453 Confirmed 18 Confirmed 0.00 0.01
48 9.147B.1 Providing and fixing factory made uPVC white colour fixed glazed windows/ ventilators comprising of uPVC multi-chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), , uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic. (CPWD DSR 2023,Vol-1, Item no.9.147B.1) SQM 38.070 995476 Confirmed 18 Confirmed 0.00 0.01
49 25.4 Extra for openable side / top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer- in- Charge.. (CPWD DSR 2023,Vol-1, Item no. 25.4) SQM 133.290 995476 Confirmed 18 Confirmed 0.00 0.01
50 10.28 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) (Ref. No. : CPWD DSR 2023,Vol-2, Page no 210, Item no.10.28) KG 877.700 995414 Confirmed 18 Confirmed 0.00 0.01
51 2.35.3.1 Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor:.(Ref. No. : CPWD DSR 2023,Vol-2, Page no 92, Item no.2.35.3.1) SQM 1883.160 995433 Confirmed 18 Confirmed 0.00 0.01
52 26.27.1 Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance ? 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-in-charge. With 16 mm thick beveled tegular mineral fibre false ceiling tile (NRC 0.55 to 0.6 .(Ref. No. : CPWD DSR 2023,Vol-2, Page no 481, Item no.26.27.1) SQM 2253.930 995475 Confirmed 18 Confirmed 0.00 0.01
53 12.45.1 Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011 (Board with BIS certification marks).(Ref. No. : CPWD DSR 2023,Vol-2, Page no 244, Item no.12.45.1) SQM 1757.900 995475 Confirmed 18 Confirmed 0.00 0.01
54 26.27.3 Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance ? 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-in-charge. With 16 mm thick beveled tegular mineral fibre Antimicrobial false ceiling tile confirming to ISO 5 (class 100) specifications .(Ref. No. : CPWD DSR 2023,Vol-2, Page no 481, Item no.26.27.3) SQM 137.543 995475 Confirmed 18 Confirmed 0.00 0.01
Automatic Censor Door
55 NDSR Providing & fixing Godrej 4316 or equivalent, Aluminium Auto door patch 1.5m length. Suitable for toughened glass applications from 10mm to 12mm thick, Max door weight capacity 140 kg. Complete set including the fixing accessories. Auto Door clamp Fittings 1.5 mtr NOS 2.000 995468 Confirmed 18 Confirmed 0.00 0.01
56 NDSR Providing & fixing Godrej 5089 or equivalent, ST25D 4.2M Automatic bi-parting covered sliding door system for frameless glass panels. Panic breakout feature which opens door 100mm by itself for safety when power failure. Suitable for 10-12 mm 2 nos thick toughened glass. DC Motor brush type with 100 Watt power, Controller SMPS type PI Control, Transformer transfers 22V to 24V minimizing loss of electric power, Hanger Roller with vertical as well as horizontal adjustment, Timing belt with saw tooth 7.4m long, On/Off Switch cum stopper, Idle Pulley, Guide roller, Main rail, Cover profile, Brackets, Single belt connector and Stopper. Modular design for varied site opening width, unique micro controller self-learning, reversing when obstruction is encountered, with adjustable parameters for opening and closing speed 100 - 450mm/sec (10 step), hold-open time 0.5 - 999 sec. Built-in inter-lock function in controller. Operator dimensions (H X T X L) 190 x 110 X 4200 mm, Max Panel Weight for Double Sliding 2 X 120 Kg, Max Panel Weight for Single Sliding 1 X 130 Kg, Clear Passage 800 - 2000 mm, Clear Passage Height 2100 - 3000 mm. The system shall have constant power supply 180 - 240V. Tested for 3 million life cycles. Door Automatic ST25D-4.2 Mtr NOS 1.000 995468 Confirmed 18 Confirmed 0.00 0.01
57 NDSR Providing & fixing Godrej 4079 or equivalent, Upper Sensor for automatic door operator from outside if the door is used only as entry door or on both sides if the door is used as entry & exit door. Maximum sensing area of 3400mm X 1600mm. Minimum sensing area of 500mm X 500mm. Easy detachable cover for adjustment of sensitivity adjustment screws. Detection angle adjustment by rotating the case of the upper cover by hand. Upper sensor NOS 2.000 995468 Confirmed 18 Confirmed 0.00 0.01
58 NDSR Providing & fixing Godrej 9009 or equivalent, Safety Sensor for automatic door operator for a sense of 10m max distance to be fitted in a hole of dia 12mm suitable for wood / wall / Al frame. Safety Sensor NOS 1.000 995468 Confirmed 18 Confirmed 0.00 0.01
59 NDSR Providing & fixing Godrej 7341 or equivalent, Central 180 Degrees Weather Seal. Soft PVC at the tip to ensure cushion . Suitable for 12mm thickness of door and for use between two glasses or between glass and wall. Made of PVC for durability and firm closing. 2.1m Length. Weather seal 180 dgree NOS 2.000 995468 Confirmed 18 Confirmed 0.00 0.01
Frameless patch fittings Doors
60 Providing & fixing of Godrej 7757 or equivalent, Top Patch with SS304 Cover in Satin Finish, Aluminium Body powder coated and Stainless Steel insert with needle bearing Dia 15mm suits standard pivot, 5mm adjustable. Suitable for toughened glass applications from 8mm to 12mm thick, Max door weight 80 kg and Max door width 1100mm. Complete set including the fixing accessories and glass cut-out. Tested to 1 Lac cycles. NOS 1.000 995468 Confirmed 18 Confirmed 0.00 0.01
61 Providing & fixing Godrej 7758 or equivalent , Bottom Patch with SS304 Cover in Satin Finish, Aluminium Body powder coated and Stainless Steel Insert suits standard floor spring spindle. Suitable for toughened glass applications from 8mm to 12mm thick, Max door weight 80 kg and Max door width 1100mm. Complete set including the fixing accessories and glass cut-out. Tested to 1 Lac cycles. NOS 1.000 995468 Confirmed 18 Confirmed 0.00 0.01
62 Providing & fixing Godrej 7771 or equivalent, Pivot Plate with SS304 Plate in Satin Finish with Steel Nickel plated Pivot Dia 15mm. Suitable for toughened glass applications Max door weight 80 kg and Max door width 1100mm. Complete set including the fixing accessories. Tested to 1 Lac cycles. NOS 1.000 995468 Confirmed 18 Confirmed 0.00 0.01
63 Providing & fixing Godrej 7759 or equivalent, Bottom Lock Patch with SS304 Cover in Satin Finish, Aluminium Body powder coated and Aluminium Deadbolt 15mm throw Nickel plated. 5 pin Euro profile cylinder with both side key, standard length 60mm in satin finish with 3 brass keys. Suitable for toughened glass applications from 8mm to 12mm thick, Max door weight 80 kg and Max door width 1100mm. Complete set including the fixing accessories and glass cut-out. Tested to 1 Lac cycles. NOS 1.000 995468 Confirmed 18 Confirmed 0.00 0.01
64 Providing & fixing Godrej 8293 or equivalent, cam based double action floor spring D80, EN size 2 fixed, compact size 50mm height with two independent closing valves, horizontal and vertical adjustment screws. Non handed installation. Max Door width 950mm, Max Door weight 80 Kg, Max opening angle 116 deg, Mechanical Hold open angle 90 deg. Std spindle and SS304 Cover in satin steel finish. Complete set including the fixing accessories. NOS 1.000 995468 Confirmed 18 Confirmed 0.00 0.01
65 Providing & fixing Godrej 2810 or equivalent, SS304 Pull handle - H-Type (25 dia. X 600 mm). 455mm centre to centre hole distance. Back to back fixing. Bevelled washer for holding the handle. Suitable for 8mm to 12mm thick glass door and upto 55mm wooden door. Complete set including the fixing accessories. NOS 1.000 995468 Confirmed 18 Confirmed 0.00 0.01
For Access Controlled Doors
66 Providing & fixing Godrej 5000 or equivalent, Advantis Crystal Digital Door lock with Autodead lock with 100 RFID cards. 4 to 12 digit password entry for more security. Random number facility to enter password in presence of stranger. Break in damage alarm. Low battery indication. Privacy function - the lock cannot be opened from outside either by RFID or Password it can be accessed via Mechanical Key only. Fire sensor - If temperature inside house rises above 65 (±5̊c), the lock automatically gets unlocked. Multilevel volume control up to 7 levels. Emergency battery facility in case of complete discharge of battery. Remote and Video Door phone compatibility. Suitable for 12mm thick glass. NOS 3.000 995468 Confirmed 18 Confirmed 0.00 0.01
67 Advantis Crystal strike Box for above NOS 3.000 995468 Confirmed 18 Confirmed 0.00 0.01
Toilet Partitions
68 NDSR Providing and installation of toilet partitions of Greenlam Classique-Versatile-Suede-1995 or equivalent complete in all respect as per direction of EIC. (Thickness 12mm, Door 600X1785, Divider Height 1820, Overall Height 1995, Depth 1550, Width 1125) NOS 16.000 995468 Confirmed 18 Confirmed 0.00 0.01
69 NDSR FRIGHT CHARGES for the above NOS 1.000 995468 Confirmed 18 Confirmed 0.00 0.01
70 NDSR 1 13 Passenger elevator with 5 stops without machine room as per specification - 282 - KONE I MonoSpace R22.1 - 4 (a. price validity 12 months from date of signing order, b. Warranty 12 months from date of handing over) NOS 2.000 995461 Confirmed 18 Confirmed 0.00 0.01
71 NDSR AMC CHARGES FOR 1 YEAR for the above NOS 1.000 995461 Confirmed 18 Confirmed 0.00 0.01
72 16.1 Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres.(CPWD DSR 2023,Vol-2, Item no.16.1) SQM 2608.000 995454 Confirmed 18 Confirmed 0.00 0.01
73 16.64 Providing and laying 75 mm thick compacted bed of dry brick aggregate of 40 mm thick nominal size including spreading, well ramming, consolidating and grouting with jamuna sand, including finishing smooth etc. complete as per direction of Engineerin- charge..(CPWD DSR 2023,Vol-2, Item no.16.64) sqm 2608.000 995454 Confirmed 18 Confirmed 0.00 0.01
74 16.91.2 Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 80 mm thick C.C. paver block of M-30 grade with approved color design and pattern(CPWD DSR 2023,Vol-2, Item no.16.91) sqm 2608.000 995454 Confirmed 18 Confirmed 0.00 0.01
75 16.43.2 Providing and laying design mix cement concrete of M-30 grade, in roads/ taxi tracks/ runways, using cement content as per design mix, using coarse sand and graded stone aggregate of 40 mm nominal size in appropriate proportions as per approved & specified design criteria, providing dowel bars with sleeve/ tie bars wherever required, laying at site, spreading and compacting mechanically by using needle and surface vibrators, levelling to required slope/ camber,finishing with required texture, including steel form work with sturdy M.S. channel sections, curing, making provision for contraction/ expansion, construction & longitudinal joints (10 mm wide x 50 mm deep) by groove cutting machine, providing and filling joints with approved joint filler and sealants, complete all as per direction of Engineer-in-charge (Item of joint fillers, sealants, dowel bars with sleeve/ tie bars to be paid separately). Cement content considered in M-30 is @ 340 kg/cum. Excess/ less cement used as per design mix is payable/ recoverable separately. Cement concrete manufactured in automatic batching plant (RMC plant) i/c transportation to site in transit mixer (CPWD DSR 2023,Vol-2, Item no.16.43) CUM 391.200 995454 Confirmed 18 Confirmed 0.00 0.01
76 16.45 Providing and fixing pre-moulded joint filler in expansion joints of RCC roads / CC pavements after making the joints dust free with high pressure air jet cleaners, all complete as per direction of the Engineer-in-Charge. (Pre-moulded joint fillers shall be made of bitumen hot sealing compound impregnated fibre board having impregnation more than 35%, conforming to IS:1838 for fibre board and IS: 1834 for hot sealing bitumen compound grade A.)(CPWD DSR 2023,Vol-2, Item no.16.45) RMT 528.000 995414 Confirmed 18 Confirmed 0.00 0.01
Post tensioned Beam
77 NDSR Design, Supply and Installation of mono-strand un-bonded Encapsulated Post-Tensioning System for Post tensioning Elements of appropriate Sizes including all Labor, machineries, tools and tackles, all consumables like Encapsulated Anchor plates, wedges etc, transportation etc, complete. Rate to include laying of tendons, stressing of tendons as per the GFC drawing. Rate to include providing drawings & designs of P-T members for gravity forces to structural consultant. Calibration certificates of jack and pump sets. Calibration certificate of pressure gauge from third party laboratory attached to pump set. These shall be available during the stressing of PT Elements for inspection. Measurement of work done will be as per the construction drawing issued by PT Designer. RMT 50500.000 995452 Confirmed 18 Confirmed 0.00 0.01
Landscaping Works
78 NDSR Supply of good quality fresh garden earth including excavation and carriage by mechnical means and stacking at site including cost of all materials labour, GST, loading and unloading royality at site etc. complete and as per direction of the engineer-in-charge. Earth measurement in stacks will be reduced by 20% for payment. Cum 651.000 995433 Confirmed 18 Confirmed 0.00 0.01
79 NDSR Collecting supplying and stacking good quality of cow dung manure from approved source and stacking at site including cost of all material labour, GST, NMR loading and unloading, at site etc. complete and as per direction of the Engineer-in-charge. Cow dung measurement in stacks will be reduced by 8% for payment. Cum 115.000 995433 Confirmed 18 Confirmed 0.00 0.01
80 NDSR supply and grassing including transportation by providing selection-1 grass digging and pulverzing of soil upto a depth of 20 cm incluidng removal of weeds debries and disposal of waste outside the perphery of area meant for lawn making, initial grading and leveling spreading and mixing of manures, fertilisers, organic meals and antitermite chemicals etc. (excluding cost of soil, manuers, fertilizer) in pulverized soil, dressing levelling landscaping the area with proper slope and making the area with proper slope and making the area suitable for grassing work including turfing, watering evenly sufficient quantities and moistering of the soil upto a depth of 5-6cm for 90 days on newly planted grass by hose pipes weeding out of the weeds growths of the newely planted grass lawn by removing all kinds of weeds with the help of suitable tools including cost and conveyence of all materials cost of all labour GST T&P etc complee as per the direction of Engineer-in-charge. Sqm 2210.000 995435 Confirmed 18 Confirmed 0.00 0.01
81 NDSR supply of approved quality of Manure like, vermi compost, Neem Cake, Harmone medicine, Insecticide medicine, antitermite medicine including cost MR and conveyence GST etc. complete as per the direction of Engineer-in-charge. Sqm 2210.000 995433 Confirmed 18 Confirmed 0.00 0.01
82 NDSR Vermi compost(50 kg Bag) bags 30.000 995433 Confirmed 18 Confirmed 0.00 0.01
83 NDSR Neem Cake bags 5.000 995433 Confirmed 18 Confirmed 0.00 0.01
84 NDSR Harmone medicine Ltr 6.000 995433 Confirmed 18 Confirmed 0.00 0.01
85 NDSR Insecticide medicine Ltr 6.000 995433 Confirmed 18 Confirmed 0.00 0.01
86 NDSR antitermite medicine Ltr 15.000 995433 Confirmed 18 Confirmed 0.00 0.01
Electro chromatic Glass
87 NDSR Providing and fixing of glazed partition with 12mm (6mm+liquid crystal film+6mm) electro chromatic glass (Saint Gobain Glass Priva-Lite® Plus or any other approved equivalent brand) to be fixed with patch fittings including top & bottom patch fittings of approved make shade & design on the glass. Glass to be tested as per URL & CE standards of approved make with power consumption of not more than 5w/sqm to be installed in glazed partition with glass performance of 76% for both the transparent and translucent state (at on & off condition) to be connected through a switch control to be provided on wall or partition or through wireless remote. The rate shall be inclusive of necessary cabling required for the glass, consoles, control fixtures, gadgets, etc. complete. sqm 52.800 995468 Confirmed 18 Confirmed 0.00 0.01
TOTAL 0.16 0.00 #REF!
# In case the bidder leaves the cell for confirmation of the SAC/HSN code and/or GST rate “blank”, the SAC/HSN code and corresponding GST rate indicated by the Employer shall be deemed to be the one confirmed by the Bidder.
Date : Printed Name :
Place : Designation :
Specification No.: ODP/BB/C&M-3575/OT-24/RFx No. 5002003243/23-24 Schedule - 1B (Electrical Works)
Construction of a Control Centre Building for OPTCL STAMS (State Transmission Asset Management System) Project by POWERGRID under Consultancy Services to OPTCL As per Lum-sum
(SCHEDULE OF RATES AND PRICES ) AS per Percent
As per lum-sum on Sch-3
Bidder’s Name and Address To: As per Percent on Sch-3
#REF! Sr. GM(C&M) Multipackage lum-sum
Name: POWER GRID CORPORATION OF INDIA LIMITED, Multipackage on Percent
Address: ODISHA PROJECTS Total Discount
PLOT NO.-4, UNIT-41, NILADRI VIHAR
CHANDRASHEKHARPUR, BHUBANESWAR-751021
Electrical WORKS All Prices are in Indian Rupees.
SI. No. Service Activity Number DSR 2022 Item Description Unit Qty. SAC/HSN Codes Whether SAC/HSN in column ‘4’ is confirmed. If not indicate applicable the SAC/HSN # Rate of GST applicable ( in %) Select from Drop-down menu. Whether rate of GST in column ‘6’ is confirmed. If not indicate applicable rate of GST # Unit Rate (excluding GST) but including labour welfare cess & Freight (if any) GST Amount Amount (Excluding GST) but including labour welfare cess & freight (if any) Unit Erection Charges Total Erection Charges
Electrical Works
1 WIRING IN STEEL AND PVC CONDUIT
1 1.3 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
c 1.3.3 Group C Point 10.000 995461 Confirmed 18 Confirmed 0.00 0.01
2 1.4 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. Point 5.000 995461 Confirmed 18 Confirmed 0.00 0.01
3 1.5 Wiring for light/power plug with 2x4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. Metre 75.000 995461 Confirmed 18 Confirmed 0.00 0.01
4 1.7 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.
a 1.7.2 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire (Ltg ) Metre 2500.000 995461 Confirmed 18 Confirmed 0.00 0.01
b 1.7.3 2 X 4 sq. mm + 1 X 4 sq. mm earth wire (RP & Ups) Metre 1500.000 995461 Confirmed 18 Confirmed 0.00 0.01
5 1.1 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
c 1.10.3 Group C Point 650.000 995461 Confirmed 18 Confirmed 0.00 0.01
6 1.11 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Point 20.000 995461 Confirmed 18 Confirmed 0.00 0.01
7 1.12 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. Metre 100.000 995461 Confirmed 18 Confirmed 0.00 0.01
8 1.14 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
a 1.14.2 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire Metre 1000.000 995461 Confirmed 18 Confirmed 0.00 0.01
b 1.14.3 2 X 4 sq. mm + 1 X 4 sq. mm earth wire Metre 750.000 995461 Confirmed 18 Confirmed 0.00 0.01
9 1.17 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
a 1.17.4 4 x 1.5 sq. mm Metre 1.000 995461 Confirmed 18 Confirmed 0.00 0.01
b 1.17.6 6 x 1.5 sq. mm Metre 1.000 995461 Confirmed 18 Confirmed 0.00 0.01
c 40195 10 x 1.5 sq. mm Metre 1.000 995461 Confirmed 18 Confirmed 0.00 0.01
10 1.18 Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.
a 1.18.2 2 Pair Metre 900.000 995461 Confirmed 18 Confirmed 0.00 0.01
b 1.18.3 4 Pair Metre 450.000 995461 Confirmed 18 Confirmed 0.00 0.01
11 1.19 Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. Metre 100.000 995461 Confirmed 18 Confirmed 0.00 0.01
12 1.21 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
a 1.21.1 20 mm Metre 2500.000 995461 Confirmed 18 Confirmed 0.00 0.01
b 1.21.2 25 mm Metre 1500.000 995461 Confirmed 18 Confirmed 0.00 0.01
c 1.21.3 32 mm Metre 1000.000 995461 Confirmed 18 Confirmed 0.00 0.01
13 1.22 Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. (Workstation boxs are excluded)
a 1.22.1 75 mm X 75 mm X 60 mm deep Each 140.000 995461 Confirmed 18 Confirmed 0.00 0.01
b 1.22.2 100 mm X 100 mm X 60 mm deep Each 120.000 995461 Confirmed 18 Confirmed 0.00 0.01
c 1.22.3 150 mm X 75 mm X 60 mm deep Each 40.000 995461 Confirmed 18 Confirmed 0.00 0.01
d 1.22.4 150 mm X 150 mm X 60 mm deep Each 15.000 995461 Confirmed 18 Confirmed 0.00 0.01
e 1.22.5 180 mm X 100 mm X 60 mm deep Each 40.000 995461 Confirmed 18 Confirmed 0.00 0.01
f 1.22.6 200 mm X 125 mm X 60 mm deep Each 20.000 995461 Confirmed 18 Confirmed 0.00 0.01
g 1.22.7 200 mm X 150 mm X 60 mm deep Each 20.000 995461 Confirmed 18 Confirmed 0.00 0.01
14 1.24 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
a 1.24.1 5/6 amps switch Each 350.000 995461 Confirmed 18 Confirmed 0.00 0.01
b 1.24.2 2 way 5/6 A switch Each 20.000 995461 Confirmed 18 Confirmed 0.00 0.01
c 1.24.3 15/16 A switch Each 100.000 995461 Confirmed 18 Confirmed 0.00 0.01
d 1.24.4 3 pin 5/6 A socket outlet Each 100.000 995461 Confirmed 18 Confirmed 0.00 0.01
e 1.24.5 6 pin 15/16 A socket outlet Each 100.000 995461 Confirmed 18 Confirmed 0.00 0.01
f 1.24.6 Telephone socket outlet Each 30.000 995461 Confirmed 18 Confirmed 0.00 0.01
g 1.24.7 TV antenna socket outlet Each 4.000 995461 Confirmed 18 Confirmed 0.00 0.01
h Data Socket Outlet Each 90.000 995461 Confirmed 18 Confirmed 0.00 0.01
15 1.25 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. Each 10.000 995461 Confirmed 18 Confirmed 0.00 0.01
16 1.26 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. Each 100.000 995461 Confirmed 18 Confirmed 0.00 0.01
17 1.27 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
a 1.27.1 1 or 2 Module (75mmX75mm) (Including Data/Tel) Each 140.000 995461 Confirmed 18 Confirmed 0.00 0.01
b 1.27.2 3 Module (100mmX75mm) Each 120.000 995461 Confirmed 18 Confirmed 0.00 0.01
c 1.27.3 4 Module (125mmX75mm) Each 40.000 995461 Confirmed 18 Confirmed 0.00 0.01
d 1.27.4 6 Module (200mmX75mm) Each 40.000 995461 Confirmed 18 Confirmed 0.00 0.01
e 1.27.5 8 Module (125mmX125mm) Each 30.000 995461 Confirmed 18 Confirmed 0.00 0.01
f 1.27.6 12 Module (200mmX150mm) Each 25.000 995461 Confirmed 18 Confirmed 0.00 0.01
18 1.28 Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.
a 1.28.1 1 or 2 Module Each 140.000 995461 Confirmed 18 Confirmed 0.00 0.01
b 1.28.2 3 Module Each 120.000 995461 Confirmed 18 Confirmed 0.00 0.01
c 1.28.3 4 Module Each 40.000 995461 Confirmed 18 Confirmed 0.00 0.01
d 1.28.4 6 Module Each 40.000 995461 Confirmed 18 Confirmed 0.00 0.01
e 1.28.5 8 Module Each 30.000 995461 Confirmed 18 Confirmed 0.00 0.01
f 1.28.6 12 Module Each 25.000 995461 Confirmed 18 Confirmed 0.00 0.01
19 1.3 Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 A socket outlet and 15/16 A piano type switch, connections, painting etc. as required. Each 10.000 995461 Confirmed 18 Confirmed 0.00 0.01
20 1.31 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. Each 120.000 995461 Confirmed 18 Confirmed 0.00 0.01
21 1.32 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16A modular switch, connections etc. as required. Each 175.000 995461 Confirmed 18 Confirmed 0.00 0.01
22 1.33 Supplying and fixing 3 pin, 5A ceiling rose on the existing junction box/ wooden block including connections etc. As required. Each 10.000 995461 Confirmed 18 Confirmed 0.00 0.01
23 1.34 Supplying and fixing brass batten/ angle holder including connection etc. as required. Each 10.000 995461 Confirmed 18 Confirmed 0.00 0.01
24 1.35 Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required. Each 50.000 995461 Confirmed 18 Confirmed 0.00 0.01
25 1.36 Supplying and fixing stiff pendent with 300 mm long, 20 mm dia X 1.6 mm thick steel conduit, aluminium cast back plate and brass holder complete, including wiring the down rod with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and painting etc. as required. Each 30.000 995461 Confirmed 18 Confirmed 0.00 0.01
26 1.39 Providing and fixing plain 16/0.20mm (0.50sqmm) twin flat flexible, FRLS PVC insulated, copper conductor cable, in PVC sleeve of suitable size on the floor/ wall, or side of the table/ door etc. as required. Metre 150.000 995461 Confirmed 18 Confirmed 0.00 0.01
27 1.4 Providing and fixing plain 16/0.20mm (0.50sqmm) twin circular flexible FRLS PVC insulated, PVC sheathed copper conductor cable direct on the wall with PVC clips etc. as required. Metre 150.000 995461 Confirmed 18 Confirmed 0.00 0.01
28 1.41 Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. Each 800.000 995461 Confirmed 18 Confirmed 0.00 0.01
29 1.42 Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc., including supplying and fixing ball and socket arrangement, 2 Nos. down rods of 20 mm dia X 1.6 mm thick steel conduit upto 30 cm length, painting and wiring the down rods and connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. Each 600.000 995461 Confirmed 18 Confirmed 0.00 0.01
30 1.45 Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. Each 10.000 995461 Confirmed 18 Confirmed 0.00 0.01
31 1.49 Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as required. Each 50.000 995461 Confirmed 18 Confirmed 0.00 0.01
32 1.5 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.
a 1.50.1 Upto 450 mm sweep Each 10.000 995461 Confirmed 18 Confirmed 0.00 0.01
b 1.50.2 510 mm sweep Each 1.000 995461 Confirmed 18 Confirmed 0.00 0.01
33 1.51 Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes. Each 10.000 995461 Confirmed 18 Confirmed 0.00 0.01
a 1.53 Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.
b 1.53.1 1 run of cable Metre 3500.000 995461 Confirmed 18 Confirmed 0.00 0.01
34 1.54 Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.
c 1.54.3 Group-C Point 35.000 995461 Confirmed 18 Confirmed 0.00 0.01
35 1.55 Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.
c 1.55.3 Group-C Point 20.000 995461 Confirmed 18 Confirmed 0.00 0.01
36 1.56 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. Each 1.000 995461 Confirmed 18 Confirmed 0.00 0.01
37 1.57 Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required. Each 5.000 995461 Confirmed 18 Confirmed 0.00 0.01
38 1.58 Supplying and fixing PVC batten/ angle holder including connections etc. as required. Each 25.000 995461 Confirmed 18 Confirmed 0.00 0.01
2 MCCB,MCB & DB
39 2.1 Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.
a 2.1.4 125A TP&N Each 2.000 995461 Confirmed 18 Confirmed 0.00 0.01
b 2.1.5 160A TP&N Each 2.000 995461 Confirmed 18 Confirmed 0.00 0.01
40 2.3 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with bar, din bar, interconnections, powder painted including tinned copper bus bar, neutral bus bar, earth earthing etc. as required. (But without MCB/RCCB/Isolator)
a 2.3.2 8 way , Double door Each 5.000 995461 Confirmed 18 Confirmed 0.00 0.01
b 2.3.3 12 way , Double door Each 2.000 995461 Confirmed 18 Confirmed 0.00 0.01
c 2.3.4 16 way , Double door Each 1.000 995461 Confirmed 18 Confirmed 0.00 0.01
41 2.4 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (lighting DB)
a 2.4.1 4 way (4 + 12), Double door Each 4.000 995461 Confirmed 18 Confirmed 0.00 0.01
b 2.4.2 6 way (4 + 18), Double door Each 4.000 995461 Confirmed 18 Confirmed 0.00 0.01
c 2.4.3 8 way (4 + 24), Double door Each 1.000 995461 Confirmed 18 Confirmed 0.00 0.01
42 2.5 Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) (RP & UPS DB)
a 2.5.1 4 way (4 + 12), Double door Each 4.000 995461 Confirmed 18 Confirmed 0.00 0.01
b 2.5.2 8 way (4 + 24), Double door Each 4.000 995461 Confirmed 18 Confirmed 0.00 0.01
43 2.1 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
a 2.10.1 Single pole Each 440.000 995461 Confirmed 18 Confirmed 0.00 0.01
b 2.10.2 Single pole and neutral Each 6.000 995461 Confirmed 18 Confirmed 0.00 0.01
c 2.10.3 Double pole Each 6.000 995461 Confirmed 18 Confirmed 0.00 0.01
d 2.10.4 Triple pole Each 20.000 995461 Confirmed 18 Confirmed 0.00 0.01
e 2.10.5 Triple pole and neutral Each 4.000 995461 Confirmed 18 Confirmed 0.00 0.01
44 2.11 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. Each 40.000 995461 Confirmed 18 Confirmed 0.00 0.01
45 2.14 Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a complete with connections, testing and commissioning etc. as required sensitivity current 30 mA in the existing MCB DB . complete with connections, testing and commissioning etc. as required.
a 2.14.2 40 A Each 2.000 995461 Confirmed 18 Confirmed 0.00 0.01
b 2.14.3 63 A Each 6.000 995461 Confirmed 18 Confirmed 0.00 0.01
46 2.15 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
a 2.15.2 40 A Each 30.000 995461 Confirmed 18 Confirmed 0.00 0.01
b 2.15.3 63 A Each 24.000 995461 Confirmed 18 Confirmed 0.00 0.01
47 2.18 Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. Each 5.000 995461 Confirmed 18 Confirmed 0.00 0.01
48 2.19 Supplying and fixing 20 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. Each 5.000 995461 Confirmed 18 Confirmed 0.00 0.01
49 2.2 Supplying and fixing 30 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 A "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. Each 2.000 995461 Confirmed 18 Confirmed 0.00 0.01
50 2.21 Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. Each 2.000 995461 Confirmed 18 Confirmed 0.00 0.01
51 2.22 Providing and fixing H.T. danger notice plate of 250 mm X 200 mm , made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. Each 2.000 995461 Confirmed 18 Confirmed 0.00 0.01
52 2.23 Supplying and fixing Cable End Box (Loose Wire Box) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 Volts, on surface/ recess, complete with testing and commissioning etc. as required.
a 2.23.2 For 8 way, Double door SPN MCBDB Each 5.000 995461 Confirmed 18 Confirmed 0.00 0.01
b 2.23.3 For 10 way, Double door SPN MCBDB Each 1.000 995461 Confirmed 18 Confirmed 0.00 0.01
c 2.23.4 For 14 way, Double door SPN MCBDB Each 2.000 995461 Confirmed 18 Confirmed 0.00 0.01
53 2.24 Supplying and fixing Cable End Box (Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc.as required.
a 2.24.1 For 4 way, Double door TPN MCBDB (Floor UPS Main DB) Each 8.000 995461 Confirmed 18 Confirmed 0.00 0.01
b 2.24.2 For 6 way, Double door TPN MCBDB Each 4.000 995461 Confirmed 18 Confirmed 0.00 0.01
c 2.24.3 For 8 way, Double door TPN MCBDB Each 14.000 995461 Confirmed 18 Confirmed 0.00 0.01
54 2.25 Supplying and fixing Cable End Box (Loose Wire Box) suitable for triple pole and neutral, sheet steel, Vertical MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc. as required. Each 4.000 995461 Confirmed 18 Confirmed 0.00 0.01
3 RAISING MAIN & BUS TRUNKING
56 3.13 Supplying, installing by suspension on ceiling, testing and commissioning of following capacity Sandwich Type Bus Duct for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply with metal clad enclosure having IP-54 rating after fixing the tap off boxes and all accessories, made of 1.6mm thick steel sheet duly powder coated in convenient sections complete with 4 Nos aluminium bus bars having current density of 130 A/ sq cm at nominal current rating, necessary joints, elbow joints & expansion joints and bends, fire barrier at each floor, provision of tapping at every metre, adopter box and copper flexible for joints, continuous earthing with 2 Nos aluminium strip of suitable size (one on each side) including, G.I. clamping brackets, suspenders, angle iron bracket, steel fasteners, connecting to earthing system etc. as required
d 3.13.6 1250 A 50kA SC for 1 sec (Sandwich Busduct Outdoor) Metre 10.000 995461 Confirmed 18 Confirmed 0.00 0.01
Note:- This item of sandwich type rising mains & rates can be used by field units for sandwich type bus trunking also by making suitable modifications in nomenclature & rates etc.
4 Hot Dipped Galvanized Iron Cable Tray
57 4.6 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.
a 4.6.1 100 mm width X 50 mm depth X 1.6 mm thickness Each 25.000 995461 Confirmed 18 Confirmed 0.00 0.01
b 4.6.2 150 mm width X 50 mm depth X 1.6 mm thickness Each 25.000 995461 Confirmed 18 Confirmed 0.00 0.01
c 4.6.3 225 mm width X 50 mm depth X 1.6 mm thickness Each 1.000 995461 Confirmed 18 Confirmed 0.00 0.01
d 4.6.4 300 mm width X 50 mm depth X 1.6 mm thickness Each 200.000 995461 Confirmed 18 Confirmed 0.00 0.01
e 4.6.6 450 mm width X 50 mm depth X 2.0 mm thickness Each 200.000 995461 Confirmed 18 Confirmed 0.00 0.01
f 4.6.14 600 mm width X 75 mm depth X 2.0 mm thickness Each 40.000 995461 Confirmed 18 Confirmed 0.00 0.01
g 4.6.15 750 mm width X 75 mm depth X 2.0 mm thickness Each 20.000 995461 Confirmed 18 Confirmed 0.00 0.01
h 4.6.16 900 mm width X 75 mm depth X 2.0 mm thickness Each 1.000 995461 Confirmed 18 Confirmed 0.00 0.01
58 4.7 Supplying and installing following size of perforated Hot Dipped Galvanised Bends (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.
a 4.7.1 100 mm width X 50 mm depth X 1.6 mm thickness Each 5.000 995461 Confirmed 18 Confirmed 0.00 0.01
b 4.7.2 150 mm width X 50 mm depth X 1.6 mm thickness Each 5.000 995461 Confirmed 18 Confirmed 0.00 0.01
c 4.7.3 225 mm width X 50 mm depth X 1.6 mm thickness Each 5.000 995461 Confirmed 18 Confirmed 0.00 0.01
d 4.7.4 300 mm width X 50 mm depth X 1.6 mm thickness Each 10.000 995461 Confirmed 18 Confirmed 0.00 0.01
e 4.7.6 450 mm width X 50 mm depth X 2.0 mm thickness Each 10.000 995461 Confirmed 18 Confirmed 0.00 0.01
f 4.7.14 600 mm width X 75 mm depth X 2.0 mm thickness Each 10.000 995461 Confirmed 18 Confirmed 0.00 0.01
g 4.7.15 750 mm width X 75 mm depth X 2.0 mm thickness Each 1.000 995461 Confirmed 18 Confirmed 0.00 0.01
h 4.7.16 900 mm width X 75 mm depth X 2.0 mm thickness Each 1.000 995461 Confirmed 18 Confirmed 0.00 0.01
59 4.8 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Tee" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.
a 4.8.1 100 mm width X 50 mm depth X 1.6 mm thickness Each 5.000 995461 Confirmed 18 Confirmed 0.00 0.01
b 4.8.2 150 mm width X 50 mm depth X 1.6 mm thickness Each 5.000 995461 Confirmed 18 Confirmed 0.00 0.01
c 4.8.3 225 mm width X 50 mm depth X 1.6 mm thickness Each 5.000 995461 Confirmed 18 Confirmed 0.00 0.01
d 4.8.4 300 mm width X 50 mm depth X 1.6 mm thickness Each 6.000 995461 Confirmed 18 Confirmed 0.00 0.01
e 4.8.6 450 mm width X 50 mm depth X 2.0 mm thickness Each 6.000 995461 Confirmed 18 Confirmed 0.00 0.01
f 4.8.14 600 mm width X 75 mm depth X 2.0 mm thickness Each 6.000 995461 Confirmed 18 Confirmed 0.00 0.01
g 4.8.15 750 mm width X 75 mm depth X 2.0 mm thickness Each 1.000 995461 Confirmed 18 Confirmed 0.00 0.01
h 4.8.16 900 mm width X 75 mm depth X 2.0 mm thickness Each 3.000 995461 Confirmed 18 Confirmed 0.00 0.01
60 5.4 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. Set 16.000 995461 Confirmed 18 Confirmed 0.00 0.01
61 5.6 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. (DG, Trafo, UPS,) Set 6.000 995461 Confirmed 18 Confirmed 0.00 0.01
62 5.8 Supplying and laying 25 mm x 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) Metre 80.000 995461 Confirmed 18 Confirmed 0.00 0.01
63 5.9 Supplying and laying 25 mm x 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including onnection/terminating with G.I. nut, bolt, spring, washer etc. as required (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) Metre 225.000 995461 Confirmed 18 Confirmed 0.00 0.01
64 5.1 Providing and fixing 25 mm x 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required. Metre 125.000 995461 Confirmed 18 Confirmed 0.00 0.01
65 5.11 Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. Metre 125.000 995461 Confirmed 18 Confirmed 0.00 0.01
66 5.14 Providing and fixing 25 mm X 5 mm COPPER strip on surface or in recess for connections etc. as required. Metre 50.000 995461 Confirmed 18 Confirmed 0.00 0.01
67 5.15 Providing and fixing 25 mm X 5 mm GI strip on surface or in recess for connections etc. as required. Metre 200.000 995461 Confirmed 18 Confirmed 0.00 0.01
68 5.16 Providing and fixing 6mm Dia GI wire on surface or in recess for loop earthing as required. Metre 200.000 995461 Confirmed 18 Confirmed 0.00 0.01
69 5.2 Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface for connections etc. as required. Metre 30.000 995461 Confirmed 18 Confirmed 0.00 0.01
6 LIGHTNING CONDUCTOR
70 6.2 Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required. Each 6.000 995461 Confirmed 18 Confirmed 0.00 0.01
71 6.3 Fixing of lightning conductor finial (single prong) with base plate including holes etc. complete as required. Each 4.000 995461 Confirmed 18 Confirmed 0.00 0.01
72 6.4 Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required. Each 100.000 995461 Confirmed 18 Confirmed 0.00 0.01
73 6.7 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or urface of wall for lightning conductor complete as required.(For horizontal run) Metre 240.000 995461 Confirmed 18 Confirmed 0.00 0.01
74 6.8 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run) Metre 100.000 995461 Confirmed 18 Confirmed 0.00 0.01
75 6.9 Fixing of copper/ G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run) Metre 120.000 995461 Confirmed 18 Confirmed 0.00 0.01
76 6.1 Fixing of copper/ G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run) Metre 50.000 995461 Confirmed 18 Confirmed 0.00 0.01
77 6.12 Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required. Each 6.000 995461 Confirmed 18 Confirmed 0.00 0.01
78 6.14 Providing and laying G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required. Metre 200.000 995461 Confirmed 18 Confirmed 0.00 0.01
79 6.15 Laying copper/ G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required. Metre 200.000 995461 Confirmed 18 Confirmed 0.00 0.01
7 MV CABLE LAYING
80 7.1 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
a 7.1.1 Upto 35 sq. mm Metre 50.000 995461 Confirmed 18 Confirmed 0.00 0.01
81 7.2 Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required.
a 7.2.2 Above 35 sq. mm and upto 95 sq. mm Metre 400.000 995461 Confirmed 18 Confirmed 0.00 0.01
b 7.2.3 Above 95 sq. mm and upto 185 sq. mm Metre 90.000 995461 Confirmed 18 Confirmed 0.00 0.01
c 7.2.4 Above 185 sq. mm and upto 400 sq. mm Metre 775.000 995461 Confirmed 18 Confirmed 0.00 0.01
82 7.8 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.
a 7.8.1 Upto 35 sq. mm (clamped with 1mm thick saddle) Metre 50.000 995461 Confirmed 18 Confirmed 0.00 0.01
b 7.8.2 Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm ms Flat clamp) Metre 400.000 995461 Confirmed 18 Confirmed 0.00 0.01
c 7.8.3 Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp) Metre 90.000 995461 Confirmed 18 Confirmed 0.00 0.01
d 7.8.4 Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp) Metre 775.000 995461 Confirmed 18 Confirmed 0.00 0.01
83 7.9 Supplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required. Metre 10.000 995461 Confirmed 18 Confirmed 0.00 0.01
8 HT CABLE LAYING
84 8.3 Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing RCC/HUME/ METAL pipe as required.
a 8.3.2 Above 120 sq. mm and upto 400 sq. mm Metre 200.000 995461 Confirmed 18 Confirmed 0.00 0.01
9 MV CABLE JOINT AND END TERMINATION
85 9.1 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
a 9.1.7 3 X 10 sq. mm (22mm) Each 10.000 995461 Confirmed 18 Confirmed 0.00 0.01
b 9.1.8 3 X 16 sq. mm (25mm) Each 10.000 995461 Confirmed 18 Confirmed 0.00 0.01
c 44440 3½ X 35 sq. mm (32mm) Each 28.000 995461 Confirmed 18 Confirmed 0.00 0.01
d 44805 3½ X 50 sq. mm (35mm) Each 12.000 995461 Confirmed 18 Confirmed 0.00 0.01
e 45170 3½ X 70 sq. mm (38mm) Each 6.000 995461 Confirmed 18 Confirmed 0.00 0.01
f 45536 3½ X 95 sq. mm (45mm) Each 4.000 995461 Confirmed 18 Confirmed 0.00 0.01
g 45901 3½ X 120 sq. mm (45mm) Each 4.000 995461 Confirmed 18 Confirmed 0.00 0.01
h 46266 3½ X 150 sq. mm (50mm) Each 4.000 995461 Confirmed 18 Confirmed 0.00 0.01
i 46631 3½ X 185 sq. mm (57mm) Each 4.000 995461 Confirmed 18 Confirmed 0.00 0.01
j 47362 3½ X 240 sq. mm (62mm) Each 4.000 995461 Confirmed 18 Confirmed 0.00 0.01
k 47727 3½ X 300 sq. mm (70mm) Each 4.000 995461 Confirmed 18 Confirmed 0.00 0.01
l 48092 3½ X 400 sq. mm (82mm) Each 24.000 995461 Confirmed 18 Confirmed 0.00 0.01
m 48458 4 X 10 sq. mm (25mm) Each 10.000 995461 Confirmed 18 Confirmed 0.00 0.01
n 48823 4 X 16 sq. mm (28mm) Each 20.000 995461 Confirmed 18 Confirmed 0.00 0.01
o 49188 4 X 25 sq. mm (28mm) Each 20.000 995461 Confirmed 18 Confirmed 0.00 0.01
86 Supply of 1100 V grade, (XLPE/PVC) insulated aluminium conductor, armoured power cable as per specifications. The cables shall be laid in cable trenches or buried directly underground or on cable trays. The cost of the cable trays or ladders, excavation and back filling of trenches will be measured separate. The unit cost of the cable shall include clamps, fasteners, saddles, tags etc. as required for proper instllation.
a NSR 124 3 X 10 sq. mm (22mm) Each 100.000 995461 Confirmed 18 Confirmed 0.00 0.01
b NSR 125 3 X 16 sq. mm (25mm) Each 100.000 995461 Confirmed 18 Confirmed 0.00 0.01
c NSR 126 3½ X 35 sq. mm (32mm) Each 25.000 995461 Confirmed 18 Confirmed 0.00 0.01
d NSR 127 3½ X 50 sq. mm (35mm) Each 350.000 995461 Confirmed 18 Confirmed 0.00 0.01
e NSR 128 3½ X 70 sq. mm (38mm) Each 90.000 995461 Confirmed 18 Confirmed 0.00 0.01
f NSR 129 3½ X 95 sq. mm (45mm) Each 50.000 995461 Confirmed 18 Confirmed 0.00 0.01
g NSR 130 3½ X 120 sq. mm (45mm) Each 50.000 995461 Confirmed 18 Confirmed 0.00 0.01
h NSR 131 3½ X 150 sq. mm (50mm) Each 50.000 995461 Confirmed 18 Confirmed 0.00 0.01
i NSR 132 3½ X 185 sq. mm (57mm) Each 80.000 995461 Confirmed 18 Confirmed 0.00 0.01
j NSR 133 3½ X 240 sq. mm (62mm) Each 40.000 995461 Confirmed 18 Confirmed 0.00 0.01
k NSR 134 3½ X 300 sq. mm (70mm) Each 280.000 995461 Confirmed 18 Confirmed 0.00 0.01
l NSR 135 3½ X 400 sq. mm (82mm) Each 500.000 995461 Confirmed 18 Confirmed 0.00 0.01
m NSR 136 4 X 10 sq. mm (25mm) Each 50.000 995461 Confirmed 18 Confirmed 0.00 0.01
n NSR 137 4 X 16 sq. mm (28mm) Each 50.000 995461 Confirmed 18 Confirmed 0.00 0.01
o NSR 138 4 X 25 sq. mm (28mm) Each 40.000 995461 Confirmed 18 Confirmed 0.00 0.01
87 NSR Supply of 1100 V grade, (XLPE/PVC) insulated Copper conductor, armoured power cable as per specifications. The cables shall be laid in cable trenches or buried directly underground or on cable trays. The cost of the cable trays or ladders, excavation and back filling of trenches will be measured separate. The unit cost of the cable shall include clamps, fasteners, saddles, tags etc. as required for proper instllation.
a NSR 139 3 X 10 sq. mm Each 90.000 995461 Confirmed 18 Confirmed 0.00 0.01
b NSR 140 3 X 16 sq. mm Each 90.000 995461 Confirmed 18 Confirmed 0.00 0.01
c NSR 141 4 X 6 sq. mm Each 90.000 995461 Confirmed 18 Confirmed 0.00 0.01
d NSR 142 4 X 10 sq. mn Each 90.000 995461 Confirmed 18 Confirmed 0.00 0.01
e NSR 143 4 X 16 sq. mm Each 90.000 995461 Confirmed 18 Confirmed 0.00 0.01
10 HV CABLE LAYING, CABLE JOINT AND END TERMINATION
88 NSR Supply and Transportation of XLPE insulated IS:7098/II/85 H.T.cable for working voltage 11 K.V Earthed with Stranded Compacted Circular Aluminium Conductor Screened with Extruded Semi-conducting compound, XLPE Insulated Screened with extruded semi-conducting compound in combination with Copper Tape, cores laid up, inner sheath of Thermoplastic tape, galvanised flat steel strip armoured and overall Extruded PVC Type ST- 2 Outer Sheathed cable etc with all necessary accessories complete as required
a NSR 143.a 3C X 300 Sqmm Each 400.000 995461 Confirmed 18 Confirmed 0.00 0.01
88.1 10.4 supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :
a 40272 300 sq. mm Each 4.000 995461 Confirmed 18 Confirmed 0.00 0.01
89 10.5 supplying and making Outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :
a 40302 300 sq. mm Each 4.000 995461 Confirmed 18 Confirmed 0.00 0.01
11 POLE ERECTION
90 11.3 Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size) foundation including excavation and refilling etc. as required.
a 40605 Above 8.0 metre and upto 10.0 metre Each 20.000 995461 Confirmed 18 Confirmed 0.00 0.01
92 11.5 Providing and making steel pole collar with cement concrete (1cement : 3 coarse sand : 6 stone aggregate 20mm) of specified size and shape including form work, plastering if required, curing etc as required. (volume of pole/ pipe not to be deducted). cum 20.000 995461 Confirmed 18 Confirmed 0.00 0.01
93 11.6 Supplying and embedding following dia G.I. pipe (medium class) in pole collar/ foundation (during casting) for cable entry including bending the pipe to the required shape complete as required.
a 40696 40 mm dia metre 20.000 995461 Confirmed 18 Confirmed 0.00 0.01
94 12.34 Supplying and fixing of 32 mm dia x 2.00 metres long G.I. Pipe (medium class) bracket for mounting of fluorescent / HPMV / HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required. Each 20.000 995461 Confirmed 18 Confirmed 0.00 0.01
14 MISC. CIVIL ITEMS
95 14.4 Excavation for cable trenches in soft soil, depth upto 1.2m including dressing of sides lift upto 1.5 m, including getting out the excavated soil, refilling with sand and or good soil after laying of cable/ pipe etc in layers of 20 cm, ramming, watering and disposal of surplus excavated soil as directed, within a lead of 50 metres. cum 70.000 995433 Confirmed 18 Confirmed 0.00 0.01
96 14.7 Providing and laying in position cement concrete 1:2:4 (1cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required. (Only DG Yard) cum 30.000 995454 Confirmed 18 Confirmed 0.00 0.01
97 14.13 Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep) and re-filling etc as required
a 14.13.3 100 mm dia metre 100.000 995462 Confirmed 18 Confirmed 0.00 0.01
b 14.13.4 150 mm dia metre 100.000 995462 Confirmed 18 Confirmed 0.00 0.01
98 14.14 Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required.
a 14.14.1 100 mm dia metre 100.000 995462 Confirmed 18 Confirmed 0.00 0.01
b 14.14.4 300 mm dia metre 200.000 995462 Confirmed 18 Confirmed 0.00 0.01
99 15.4 Supplying, installation, testing and commissioning of Astronomical time switch of following configuration to be mounted in feeder pillars / Lighting DBs for automatic switching On & OFF of street lights at sun set & sun rise or twilight(Auto ON, Auto OFF, Auto modes) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete as required.
a 15.4.3 3 output (1output per phase) and suitable for three phase supply Each 4.000 995461 Confirmed 18 Confirmed 0.00 0.01
100 NSR Design, Fabrication, Supply, erection, testing and commissioning of HT Panel boards of cubicle floor mounting type made out of 14/16 Gauge CRCA sheet steel construction dust and vermin proof for indoor use degree of protection is IP55 (Outdoor), extensible on both sides, rated for 433V, 3phase 50 Hz AC supply 4 wire system. The painting of the complete system shall be by powder coating (The colour as per the choice of the client) or as per the requirement of the employer. All the panel boards should be with suitable cable chamber for outgoing cables with suitable removal type gland plates. All switch boards shall be complete with double Earthing arrangements in entire length of the panel and cable chambers using sutiable rating of aluminium flats, feeder identifications, etc., as per Standards
a NSR 144 RMU Each 2.000 8414 Confirmed 18 Confirmed 0.00 0.01
b NSR 145 Metering Cubicle Each 2.000 8414 Confirmed 18 Confirmed 0.00 0.01
c NSR 146 HT Panel (Single VCB Panel) Each 2.000 8414 Confirmed 18 Confirmed 0.00 0.01
17 Low Voltage Switchgear
101 NSR Design, Fabrication, Supply, erection, testing and commissioning of LT Panel boards of cubicle floor mounting type made out of 14/16 Gauge CRCA sheet steel construction dust and vermin proof for indoor use degree of protection is IP52, extensible on both sides, rated for 433V, 3phase 50 Hz AC supply 4 wire system. The painting of the complete system shall be by powder coating (The colour as per the choice of the client) or as per the requirement of the employer. All the panel boards should be with suitable cable chamber for outgoing cables with suitable removal type gland plates. All switch boards shall be complete with double Earthing arrangements in entire length of the panel and cable chambers using sutiable rating of aluminium flats, feeder identifications, etc., as per Standards.
a NSR 147 Main LT Panel Each 2.000 8414 Confirmed 18 Confirmed 0.00 0.01
b NSR 148 HVAC panel Each 2.000 8414 Confirmed 18 Confirmed 0.00 0.01
c NSR 149 APFC Panel Each 2.000 8414 Confirmed 18 Confirmed 0.00 0.01
d NSR 150 Utility Panel Each 2.000 8414 Confirmed 18 Confirmed 0.00 0.01
e NSR 151 Main Lift Panel Each 2.000 8414 Confirmed 18 Confirmed 0.00 0.01
f NSR 152 Lift Panel Each 10.000 8414 Confirmed 18 Confirmed 0.00 0.01
g NSR 153 UPS I/P Panel Each 2.000 8414 Confirmed 18 Confirmed 0.00 0.01
h NSR 154 GF Lighting/RP Panel Each 2.000 8414 Confirmed 18 Confirmed 0.00 0.01
i NSR 155 FF Lighting/RP Panel Each 2.000 8414 Confirmed 18 Confirmed 0.00 0.01
j NSR 156 2F Lighting/RP Panel Each 2.000 8414 Confirmed 18 Confirmed 0.00 0.01
k NSR 157 3F Lighting/RP Panel Each 2.000 8414 Confirmed 18 Confirmed 0.00 0.01
l NSR 158 common area panel Each 2.000 8414 Confirmed 18 Confirmed 0.00 0.01
m NSR 159 UPS O/P Panel Each 2.000 8414 Confirmed 18 Confirmed 0.00 0.01
n NSR 160 Ventilation Panel Each 2.000 8414 Confirmed 18 Confirmed 0.00 0.01
o NSR 161 LT Kiosk Each 2.000 8414 Confirmed 18 Confirmed 0.00 0.01
18 CLOSED CIRCUIT TELEVISION SYSTEM
102 NSR 162 5MP IR Bullet Fixed Camera -1/2.8"Progressive Scan CMOS, 1920 × 1080 at 25fps, 2.8 mm Fixed lens, 0.01 Lux at F1.2, 0 Lux with IR, ICR, ONVIF (PROFILE S, PROFILE G), support H.265, H.264, MJPEG, 120dbDWDR, 3D Digital Noise Reduction, Three individually configurable stream, 12 VDC & PoE, IR range: 30m, , UL, CE, FCC certified. IP66 HBD2PER1 Nos 2.000 998313 Confirmed 18 Confirmed 0.00 0.01
103 NSR 163 5MP IR Indoor Dome Fixed Camera -1/2.8"Progressive Scan CMOS, 1920 × 1080 at 25fps, 2.8mm Fixed lens, 0.01 Lux at F1.2, ICR, ONVIF, support H.265, H.264, MJPEG, 120db DWDR, 3D Digital Noise Reduction, Three individually configurable stream, 12 VDC & PoE, IR range: 30m, UL, CE, FCC certified. IP66 HED2PER3 Nos 40.000 998313 Confirmed 18 Confirmed 0.00 0.01
104 NSR 164 IP based Outdoor PTZ Camera: 1/2.7" Progressive Scan CMOS, ICR, 0.01 lux at F1.2, 0 lux with IR, 1080P:25fps, 2.8mm Fixed Lens, H.265, MJPEG, Three individually configurable stream, IK08, IP66, DC12V & POE, 120dB WDR, 3D DNR, BLC, Support on-board storage up to 128GB (SD card not included), Alarm -1 input,1 output, IR range: up to 10m, Edge Anlalytics- Line crossing detection, intrusion detection, Motion detection,face detection, video tampering, UL, CE, FCC certified. Nos 4.000 998313 Confirmed 18 Confirmed 0.00 0.01
105 NSR 165 64ch Network Video Recorder-Connect Up to 64 IP Cameras, Dual OS, Up to 12 Megapixels Resolution, Two independent HDMI outputs, one HDMI output of 4K resolution, Two independent VGA outputs, 1 VGA output with output upto 1920 × 1080, Support H.265, MJPEG, Supports N+1 hot spare system, Supports RAID0, RAID1, RAID5, RAID6 and RAID10, Supports HDD hot swap, Supports Dual Power-Redundant,Incoming Bandwidth 320 Mbps, 8 SATA Hard Disks, ANR Technology, 8 SATA interfaces for 8 HDDs and capacity of each HDD upto 8TB, 3 × USB at least 1 × USB with 3.0, Alarm I/O 16/4, RS-485, RS-232, 2 RJ-45 10 /100/1000 Mbps self-adaptive Ethernet interface, Multiple network monitoring: Web viewer, CE, FCC, UL certified. Nos 1.000 998313 Confirmed 18 Confirmed 0.00 0.01
106 NSR 166 6TB Surveillance Hard Disk Nos 1.000 998313 Confirmed 18 Confirmed 0.00 0.01
107 NSR 167 24 port Unmanaged Network PoE Switch: L2, Unmanaged, 16 100M PoE port, 2 1000M combo port, 802.3af/at, PoE power budget 230W Nos 5.000 998313 Confirmed 18 Confirmed 0.00 0.01
108 NSR 168 Master Server License including media directory, archiving, recording, failover, full blown feature set, unlimited servers support with Analytics. Lsm 1.000 998313 Confirmed 18 Confirmed 0.00 0.01
109 NSR 169 IVMS - Camera Connection License Nos 46.000 998313 Confirmed 18 Confirmed 0.00 0.01
110 NSR 170 Server for Video Management Software Nos 1.000 998313 Confirmed 18 Confirmed 0.00 0.01
111 NSR 171 21" LCD 24X7 Surveillance Monitor Nos 1.000 998313 Confirmed 18 Confirmed 0.00 0.01
19 LIGHT FIXTURE
112 NSR Supply, Installation, testing and Commissioning of luminaires complete with fixture, lamps, ballast, starter, HPF condenser, standard down rod, connecting cord, etc.,. The rate shall include all necessary fixing accessories like MS hooks, MS supports, fasteners, etc. Note: Catalogue numbers indicated are only to describe type of light fixture required. Lamp Colour shall be - 84 or as approved by Architect / Consultant.
a NSR 201 600x600MM 36W LED, RECESS MOUNTED SLIM EDGE LIT TYPE ELITE LED LUMINAIRE. No's 400.000 8414 Confirmed 18 Confirmed 0.00 0.01
b NSR 202 20W 4' SURFACE/WALL MOUNTED BATTEN TYPE CAPSULE IP65 LED FIXTURE. No's 100.000 8414 Confirmed 18 Confirmed 0.00 0.01
c NSR 203 18W RECESS MOUNTED SLIM CIRCULAR TYPE MOLLIS LED DOWN LIGHTER. No's 200.000 8414 Confirmed 18 Confirmed 0.00 0.01
d NSR 204 15W RECESS MOUNTED CIRCULAR TYPE IRIS SLIM LED DOWN LIGHTER. No's 40.000 8414 Confirmed 18 Confirmed 0.00 0.01
g NSR 207 10W TRIM MIRROR LIGHT. No's 10.000 8414 Confirmed 18 Confirmed 0.00 0.01
h NSR 208 10W LED BULKHEAD LIGHT FIXTURE. No's 20.000 8414 Confirmed 18 Confirmed 0.00 0.01
i NSR 209 300X300M 16W LED SQUARE DOWN LIGHT FIXTURE. No's 50.000 8414 Confirmed 18 Confirmed 0.00 0.01
j NSR 210 5W / METER LED STRIP WITH DRIVER No's 1.000 8414 Confirmed 18 Confirmed 0.00 0.01
k NSR 211 SPOT LIGHT - Recess mounted adjustable 2x25W LED spot light No's 1.000 8414 Confirmed 18 Confirmed 0.00 0.01
l NSR 211a Ceiling fan 48" Sweep 5 Star (1200 mm) No's 10.000 8414 Confirmed 18 Confirmed 0.00 0.01
m NSR 211b Supplying exhaust fan of 1440 RPM of 300/450 mm size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. No's 10.000 8414 Confirmed 18 Confirmed 0.00 0.01
113 20 TRANSFORMER
a NSR 212 Supply, erection, testing and commissioning 11KV/0.433KV, 630 KVA, Outdoor Duty, Oil cooled type, Two winding, low loss and low noise design, Three phase, 50Hz, ONAN cooled, vector group Dyn11 & Percentage of impedance 5% as per IS 2026 ( Part-1)with no negative tolerance, having cable box on HV side and LV side with extended bus bar supprot for cable connections with all accessories as required. Load losses shall be as per IS 2026(part-1) The losses figures as indicated while submitting GTP, shall be maximum and shall not have any positive tolerance. The transformer OLTC shall have the tapings of +5% -15% in steps of 2.5%. Each 2.000 995423 Confirmed 18 Confirmed 0.00 0.01
114 21 RACE WAY
I NSR Supply and Installation of following size G I Raceways of 2mm thick with top cover and required hard ware etc suspended from the ceiling or Along the wall or in trench, in floor or on floor,
a NSR 213 100 X 40 mm Mtrs 100.000 995461 Confirmed 18 Confirmed 0.00 0.01
b NSR 214 150mm x 40mm Mtrs 100.000 995461 Confirmed 18 Confirmed 0.00 0.01
c NSR 215 300mm x 40mm Mtrs 100.000 995461 Confirmed 18 Confirmed 0.00 0.01
II JUNCTION BOX
d NSR 216 172 x 172 x 58mm with 2mm cover & 2mm base Nos 15.000 995461 Confirmed 18 Confirmed 0.00 0.01
e NSR 217 272 x 272 x 58mm with 2mm cover & 2mm base Nos 15.000 995461 Confirmed 18 Confirmed 0.00 0.01
f NSR 218 372 x 372 x 58mm with 2mm cover & 2mm base Nos 15.000 995461 Confirmed 18 Confirmed 0.00 0.01
a NSR 219 Supply, Unloading , Installation, testing & commissioning of 40 KVA/ 27kW UPS with three phase input & Three phase true sine wave output and sealed maintanence free batteries for 15 minutes backup.complete with all accessories.such as suitabley rated TPN MCB /MCCB isolators on both I/P and O/P sides, 150mm Height Base frame for UPS Mounting, open type powder coated racks for Battery, Battery Circuit Breaker with Under Voltage coil, Battery cables(DC) with Min 20Mtrs Length , termibation of cables, etc., complete as required. Each 1.000 995461 Confirmed 18 Confirmed 0.00 0.01
b NSR 220 Supply, Unloading , Installation, testing & commissioning of 60 KVA UPS with three phase input & Three phase true sine wave output and sealed maintanence free batteries for 15 minutes backup.complete with all accessories.such as suitabley rated TPN MCB /MCCB isolators on both I/P and O/P sides, 150mm Height Base frame for UPS Mounting, open type powder coated racks for Battery, Battery Circuit Breaker with Under Voltage coil, Battery cables(DC) with Min 20Mtrs Length , termibation of cables, etc., complete as required. Each 1.000 995461 Confirmed 18 Confirmed 0.00 0.01
I NSR 1010 KVA DG SET with Acoustic & AMF Panel
a NSR 221 Supply, Installation, testing and commissioning of 500KVA Silent type Diesel Generator Set complete with Diesel Engine suitable for Generator application, developing 1500RPM with an overloading capacity of 10% for one hour in AFTER 12 continuous hours opeartion Generally confirms to BS:5514, directly coupled to 500 kVA at 0.8 Power factor, 415V, 3 Phase , 4 wires, 50 cycles per second self excited, self regulated , with brushless excitation, Alternator generally confirms to BS:5000/IS:4722 . DG set shall be complete with radiator, Residential type silencer, electronic governor, cable termination box , MS mounting frame, fuel piping, diesel day tank, 24VDC Battery, Battery mounting frame, oil level indicator with guage board, and all other accessories as per specifications and schedule. Diesel Generator set shall be The DG Set shall be suitable for auto-mains failure start and auto / manual operations. The cost shall include fuel oil required for testing DG Set at full load. The cost shall include All civil works for 500 kVA DG set foundation with all neccessory accessories. The cost is inclusive of Standard AMF panel and Fule indicator. Set 2.000 995461 Confirmed 18 Confirmed 0.00 0.01
24 Exhaust System
117 Supply and providing exhaust piping complete with exhaust pipe, fibre glass insulation with aluminium cladding, pipe accessories like flanges, bends, elbows, rain protection hoods, etc.. The exhaust piping shall be fixed from floor with MS angle supports, using necessary clamps, anchorbolts, vibration isolation pads, etc., as shown in the drawing. Pipe size shall be suitable for 1010KVA Diesel generator set.
a NSR 223 8" dia - MS Class "B" Exhaust pipe (Bends will be measures double) with all necessary fittings Mtrs 40.000 995461 Confirmed 18 Confirmed 0.00 0.01
b NSR 224 50 mm Thick Thermal insulation of 8" MS Exhaust pipe.(Bends will be measures double). Mtrs 40.000 995461 Confirmed 18 Confirmed 0.00 0.01
c NSR 225 Supply and Installation of exhaust piping with 12" dia MS pipe including Hardware, Nutbolts, Flanges & Gaskets steel supports (1010KVA DG Set) Mtr 40.000 995461 Confirmed 18 Confirmed 0.00 0.01
d NSR 226 Supply & installation of 12" Bend.(Bends shall be measured Extra @1 Mtr) Nos 8.000 995461 Confirmed 18 Confirmed 0.00 0.01
e NSR 227 Supply & installation of 50 mm thk. Insulation with rockwool density-64 kg/cm3 and 24 guage aluminium cladding for 10" MS Pipe for 1010KVA DG set Mtr 40.000 995461 Confirmed 18 Confirmed 0.00 0.01
f NSR 228 Supply & installation of 50 mm thk. Insulation with rockwool density-64 kg/cm3 and 24 guage aluminium cladding for Silencer for 1x1010KVA DG set Nos 8.000 Confirmed 18 Confirmed 0.00 0.01
g NSR 229 Supply, Fabrication & Installation of 1" dia class 'B' MS Pipe Mtr 50.000 995461 Confirmed 18 Confirmed 0.00 0.01
h NSR 230 Supply & Fixing of 1" dia Ball Valve in fuel line Set 2.000 995461 Confirmed 18 Confirmed 0.00 0.01
i NSR 231 Supply & Installation of 990 Ltrs Day Tank Nos 2.000 995461 Confirmed 18 Confirmed 0.00 0.01
j NSR 232 Supply & Installation of MS Steel structure & support for exhaust pipe, silencers and misc. supports with 1 coat of red oxide & 2 coats of enamel paint (Including fastners wherever required Kg 8000.000 995461 Confirmed 18 Confirmed 0.00 0.01
118 Control Cablea & Terminations:
Supply, laying, testing and commissioning of following sizes of 1100Volts Copper Armoured Control Cables
a NSR 233 4C x 2.5 Sq.mm Mtr 100.000 995468 Confirmed 18 Confirmed 0.00 0.01
b NSR 234 12C x 2.5 Sqmm Mtr 100.000 995468 Confirmed 18 Confirmed 0.00 0.01
119 End Terminations for above sizes of Copper Armoured Control Cables with all required accessories
a NSR 235 4C x 2.5 Sq.mm Nos 8.000 995468 Confirmed 18 Confirmed 0.00 0.01
b NSR 236 12C x 2.5 Sqmm Nos 8.000 995468 Confirmed 18 Confirmed 0.00 0.01
TOTAL 0.48 0.00 #REF!
# In case the bidder leaves the cell for confirmation of the SAC/HSN code and/or GST rate “blank”, the SAC/HSN code and corresponding GST rate indicated by the Employer shall be deemed to be the one confirmed by the Bidder.
Date : Printed Name :
Place : Designation :
Specification No.: ODP/BB/C&M-3575/OT-24/RFx No. 5002003243/23-24 Schedule - 1C (Plumbing Works)
Construction of a Control Centre Building for OPTCL STAMS (State Transmission Asset Management System) Project by POWERGRID under Consultancy Services to OPTCL As per Lum-sum
(SCHEDULE OF RATES AND PRICES ) AS per Percent
As per lum-sum on Sch-3
Bidder’s Name and Address To: As per Percent on Sch-3
#REF! Sr. GM(C&M) Multipackage lum-sum
Name: POWER GRID CORPORATION OF INDIA LIMITED, Multipackage on Percent
Address: ODISHA PROJECTS Total Discount
PLOT NO.-4, UNIT-41, NILADRI VIHAR
CHANDRASHEKHARPUR, BHUBANESWAR-751021
Plumbing WORKS All Prices are in Indian Rupees.
SI. No. Service Activity Number DSR 2023/NSR Item Description Unit Qty. SAC/HSN Codes Whether SAC/HSN in column ‘4’ is confirmed. If not indicate applicable the SAC/HSN # Rate of GST applicable ( in %) Select from Drop-down menu. Whether rate of GST in column ‘6’ is confirmed. If not indicate applicable rate of GST # Unit Rate (excluding GST) but including labour welfare cess & Freight (if any) GST Amount Amount (Excluding GST) but including labour welfare cess & freight (if any) Unit Erection Charges Total Erection Charges
A SANITORY FIXTURES
1 17.2 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :
A 17.2.1 W.C. pan with ISI marked white solid plastic seat and lid Nos 26.000 999459 Confirmed 18 Confirmed 0.00 0.01
2 17.5 Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required :
A 17.5.1 Single half stall urinal with 5 litre P.V.C. automatic flushing cistern Nos 8.000 999459 Confirmed 18 Confirmed 0.00 0.01
3 17.6 Providing and fixing one piece construction white vitreous china squatting plate with an integral longitudinal flushing pipe, white P.V.C. automatic flushing cistern, with fittings, standard size G.I. / PVC flush pipe for back and front flush with standard spreader pipes with fittings, G.I clamps and C.P. brass coupling complete, including painting of fittings and cutting and making good the walls and floors etc. wherever required :
A 17.6.1 Single squatting plate with 5 litre P.V.C. automatic flushing cistern Nos 26.000 999459 Confirmed 18 Confirmed 0.00 0.01
4 17.7 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:
A 17.7.1 White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps Nos 34.000 999459 Confirmed 18 Confirmed 0.00 0.01
5 17.1 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :
A 17.10.1 Kitchen sink with drain board
B 7.10.1.1 510x1040 mm bowl depth 250 mm Nos 6.000 999459 Confirmed 18 Confirmed 0.00 0.01
6 17.31 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. Nos 34.000 999459 Confirmed 18 Confirmed 0.00 0.01
7 17.34 Providing and fixing toilet paper holder :
A 17.34.1 C.P. brass Nos 34.000 999459 Confirmed 18 Confirmed 0.00 0.01
8 17.71 Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. Nos 34.000 999459 Confirmed 18 Confirmed 0.00 0.01
9 17.72 Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. Nos 34.000 999459 Confirmed 18 Confirmed 0.00 0.01
10 17.73. Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.
A 17.73.2 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. Nos 34.000 999459 Confirmed 18 Confirmed 0.00 0.01
11 NSR 1 Providing ,fixing , testing and commissioning 15 mm dia. CP angle Pressure rating minimum of 5 bar the equipment should be provided. Nos 77.000 999459 Confirmed 18 Confirmed 0.00 0.01
12 NSR 2 Providing ,fixing , testing and commissioning of 15mm CP health faucet of approved make with 1 no angle valve with necessary CP flexible hose 750 mm long nozzle,CP wall flange complete. Nos 26.000 999459 Confirmed 18 Confirmed 0.00 0.01
B EXTERNAL DRAINAGE SYSTEM
1 19.4 Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:
a 100x100 mm size P type
i 19.4.1.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 Nos 10.000 999411 Confirmed 18 Confirmed 0.00 0.01
2 19.28 Constructing brick masonry road gully chamber 45x45x77.5 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand ) with precast R.C.C. vertical grating complete as per standard design
a 19.28.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 Nos 10.000 999411 Confirmed 18 Confirmed 0.00 0.01
3 19.3 Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design:
19.30.2 Inside dimensions 500x700 mm and 45 cm deep for pipe line with one or two inlets :
A 19.30.2.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 Nos 11.000 995456 Confirmed 18 Confirmed 0.00 0.01
4 19.11 Constructing brick masonry circular manhole 1.22 m internal dia at bottom and 0.56 m dia at top in cement mortar 1:4 (1 cement :4 coarse sand) inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement foundation concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design :
1.68 m deep with SFRC Cover and frame (heavy duty HD-20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg. fixed in cement concrete 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately) :
A 19.11.1.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 Nos 7.000 995456 Confirmed 18 Confirmed 0.00 0.01
5 19.12.1 Extra depth for circular type manhole 1.22 m internal dia (at bottom) beyond 1.68 m to 2.29 m :
A With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 Nos 8.000 995456 Confirmed 18 Confirmed 0.00 0.01
6 NSR 3 Supplying, fixing and testing PVC soil, waste (SWR)/Pressure confirming to IS 13592 : 1990, type B with rubber ring/Solvent (confirming toIS5382) joint inclusive of all necessary specials like bends, tees,offsets, door bends, junctions,cowls,etc.,laid underfloor/ fixed on walls,and in pipe shafts etc., complete.The rate shall include necessary GI supports, GI grip bolts, angle brackets, hangers, supports as with suitable GI U-clamps, bolts, nuts and washers etc., The clamps shall be painted with two coats of enamel (approved) paint over a coat of primer etc., complete.
a a 200 mm dia Rmt 68.000 995462 Confirmed 18 Confirmed 0.00 0.01
b b 160mm dia Rmt 107.000 995462 Confirmed 18 Confirmed 0.00 0.01
c c 110 mm dia Rmt 329.000 995462 Confirmed 18 Confirmed 0.00 0.01
d d 75 mm dia Rmt 135.000 995462 Confirmed 18 Confirmed 0.00 0.01
7 NSR 4 Providing and fixing in position PVC single/multi floor trap including providing necessary support. Making proper connection cutting chase / hole in floors / slabs and bringing the same in proper condition and shape after placing the trap in right position complete as required. The trap shall be set in cement concrete mix 1:2:4 complete as required. Nos 48.000 995462 Confirmed 18 Confirmed 0.00 0.01
8 NSR 5 Providing and fixing thick CP brass hinged grating with rim of with 150mm dia inlet and 100mm dia outlet fixed on a bed of cement concrete etc.approved design including setting in floor with cement mortar (as per Architect).ForLandscape area Nos 48.000 995462 Confirmed 18 Confirmed 0.00 0.01
9 NSR 6 Providing ,fixing , testing and commissioning of clean outs fabricated from heavy duty PVC pipe for waste and soil lines inside toilets for effective maintenance, laid true to finished floor level with brass chromium plated frame and screw type of cover and key for opening etc., complete
A A 75mm dia Nos 10.000 995462 Confirmed 18 Confirmed 0.00 0.01
B B 110mm dia Nos 10.000 995462 Confirmed 18 Confirmed 0.00 0.01
10 NSR 7 Drilling with core cutting machine in RCC(up to 300 mm thick) beams, slabs floors etc.,for laying pipes and rendering the same in RCC 1:2:4, finishing the same to the satisfaction of the Owner or his authorized representative etc.,including nominal reinforcement where ever required, complete. The quoted rate shall also include for providing EPOXY based water proofing compound for sealing the joints around the pipes.
A up to 250 mm dia. Nos 150.000 995462 Confirmed 18 Confirmed 0.00 0.01
11 NSR 8 Providing, fixing and jointing uPVC waste water pipes conforming to IS:4985 :2000 from kitchen wash basin etc the quoted rate including all fittings such as bends, clamps, tees, cowls, clean out plugs etc, complete with suitable type of supports( fabricated by angles, channels, flats etc, with painting with fasteners), anchor fasteners, bolts nuts ( Galvanized), clamps, "U" bolts, Including cutting, fixing in / on walls, ceiling by using suitable supports etc, as per drawings. The quoted rate shall also inclusive of civil work in PCC walls and making them good with filler material and finished in cement mortar etc. complete.
A A 32 mm OD -WB Rmt 50.000 995462 Confirmed 18 Confirmed 0.00 0.01
B B 50 mm OD -Sink Rmt 5.000 995462 Confirmed 18 Confirmed 0.00 0.01
1 18.7 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.
Internal work - Exposed on wall
a 18.7.2 20 mm nominal dia Pipes Rmt 100.000 996921 Confirmed 18 Confirmed 0.00 0.01
b 18.7.3 25 mm nominal dia Pipes Rmt 30.000 996921 Confirmed 18 Confirmed 0.00 0.01
c 18.7.4 32 mm nominal dia Pipes Rmt 190.000 996921 Confirmed 18 Confirmed 0.00 0.01
d 18.7.5 40 mm nominal dia Pipes Rmt 120.000 996921 Confirmed 18 Confirmed 0.00 0.01
e 18.7.6 50 mm nominal dia Pipes Rmt 78.000 996921 Confirmed 18 Confirmed 0.00 0.01
2 18.8 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.
Concealed work, including cutting chases and making good the walls etc.
a 18.8.2 20 mm nominal dia Pipes Rmt 200.000 996921 Confirmed 18 Confirmed 0.00 0.01
b 18.8.3 25 mm nominal dia Pipes Rmt 60.000 996921 Confirmed 18 Confirmed 0.00 0.01
3 18.9 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.
a 18.9.3 25 mm nominal dia Pipes Rmt 100.000 996921 Confirmed 18 Confirmed 0.00 0.01
4 18.17 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :
a 18.17.1A 20mm dia Nos 22.000 996921 Confirmed 18 Confirmed 0.00 0.01
b 18.17.1 25mm dia Nos 15.000 996921 Confirmed 18 Confirmed 0.00 0.01
c 18.17.2 32 mm dia Nos 4.000 996921 Confirmed 18 Confirmed 0.00 0.01
d 18.17.3 40 mm dia Nos 4.000 996921 Confirmed 18 Confirmed 0.00 0.01
e 18.17.4 50mm dia Nos 4.000 996921 Confirmed 18 Confirmed 0.00 0.01
5 18.18 Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete
a 18.18.3 25 mm dia Nos 4.000 996921 Confirmed 18 Confirmed 0.00 0.01
6 18.6 Providing and fixing enclosed type water meter (bulk type) conforming to IS : 2373 and tested by Municipal Board complete with bolts, nuts, rubber insertions etc. (The tail pieces if required will be paid separately) :
a 18.60.1 80mm dia - Municiple meter Nos 1.000 996921 Confirmed 18 Confirmed 0.00 0.01
18.61 Providing and fixing C.I. dirt box strainer for bulk type water meter with nuts, bolts, rubber insertions etc. complete conforming to IS : 2373 :
b 16.61.1 80 mm dia Nos 1.000 996921 Confirmed 18 Confirmed 0.00 0.01
7 18.37 Constructing masonry Chamber 60x45x50 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for water meter complete with C.I. double flap surface box 400x200x200 mm (inside) with locking arrangement and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) , i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand:10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design :
a 18.37.1 With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 Nos 1.000 996921 Confirmed 18 Confirmed 0.00 0.01
8 NSR 9 Supplying, fixing and testing inlet, outlet, vent and overflow pipes, fittings with CI frame and cover to under ground and over head water tank complete with PVC Rungs as shown on the drawings etc., complete, accessories comprising of the following Set 1.000 996921 Confirmed 18 Confirmed 0.00 0.01
Approx. depth = 3.5 to 4.0Mts.
i) DI manhole frame and cover (Heavy duty ) with locking facility Nos 14.000
250 dia fire outlet nos 2.000
100dia (Tanker) nos 1.000
150 dia FBIC/ test line nos 2.000
25dia (from Minicipal) nos 1.000
iii) Outlet puddle flanges nos 1.000
80dia (Domestic suction outlet) nos 1.000
100dia (Fire over flow to Raw water tank) nos 2.000
65dia (Raw water Suction outlet to filter feed pump) nos 1.000
50dia (Inlet to treated water tank)) nos 1.000
65dia overflow pipe (Raw and trearted tank) nos 2.000
80dia Treated water outlet nos 1.000
iv) 100dia Vent pipe with mosquito proof mesh nos 6.000
v) Heavy duty 450mm wide PVC step ladder nos 60.000
vii)50dia Sleeves for level controller nos 4.000
viii.)50dia Drain pipe puddle flange nos 4.000
Note : All puddle flanges to be hot dip galvanised.
9 NSR 10 Supplying, fixing and testing commissioning of float valve of 32 mm dia Set 3.000 996921 Confirmed 18 Confirmed 0.00 0.01
D STORM WATER DRAINAGE
1 19.6 Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :
a 19.6.2 150 mm dia. R.C.C. pipe Rmt 50.000 999411 Confirmed 18 Confirmed 0.00 0.01
b 19.6.3 250 mm dia. R.C.C. pipe Rmt 100.000 999411 Confirmed 18 Confirmed 0.00 0.01
c 19.6.4 300 mm dia. R.C.C. pipe Rmt 100.000 999411 Confirmed 18 Confirmed 0.00 0.01
d 19.6.5 450 mm dia. R.C.C. pipe Rmt 100.000 999411 Confirmed 18 Confirmed 0.00 0.01
2 19.3 Constructing brick masonry chamber for underground C.I. inspection chamber (For rain water) and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design:
I19.30.1 Inside dimensions 455x610 mm and 45 cm deep for single pipe line :
a 19.30.1.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 Nos 3.000 995456 Confirmed 18 Confirmed 0.00 0.01
19.30.2 Inside dimensions 500x700 mm and 45 cm deep for pipe line with one or two inlets :
b 19.30.2.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 Nos 3.000 995456 Confirmed 18 Confirmed 0.00 0.01
3 19.31 Extra for depth beyond 45 cm of brick masonry chamber :
19.31.1 For 455x610 mm size
a 19.31.1.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 Nos 5.000 995456 Confirmed 18 Confirmed 0.00 0.01
4 19.31.2 For 500x700 mm size
a 19.31.2.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 Nos 5.000 995456 Confirmed 18 Confirmed 0.00 0.01
5 19.11 Constructing brick masonry circular manhole 1.22 m internal dia at bottom and 0.56 m dia at top in cement mortar 1:4 (1 cement :4 coarse sand) inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement foundation concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design :
19.11.1 1.68 m deep with SFRC Cover and frame (heavy duty HD20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg. fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately) :
a 19.11.1.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 Nos 10.000 995456 Confirmed 18 Confirmed 0.00 0.01
6 23.1 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata,preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level.
23.1.1 All types of soil
a 23.1.1 .1 300 mm dia rmt 300.000 999411 Confirmed 18 Confirmed 0.00 0.01
7 Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge.
a 23.3.2 150 mm dia rmt 450.000 999411 Confirmed 18 Confirmed 0.00 0.01
8 23.5 Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. cum 7.000 999411 Confirmed 18 Confirmed 0.00 0.01
9 23.6 Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. cum 7.000 999411 Confirmed 18 Confirmed 0.00 0.01
10 23.7 Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. cum 7.000 999411 Confirmed 18 Confirmed 0.00 0.01
11 23.8 Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. cum 7.000 999411 Confirmed 18 Confirmed 0.00 0.01
12 23.9 Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineer-in-charge. nos 15.000 999411 Confirmed 18 Confirmed 0.00 0.01
13 23.13 Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of:
a 23.13.2 150 mm dia nos 15.000 999411 Confirmed 18 Confirmed 0.00 0.01
14 23.14 Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete.
a 23.14.2 150 mm clamp nos 15.000 999411 Confirmed 18 Confirmed 0.00 0.01
15 23.15 Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I).
a 23.15.2 150 mm dia nos 15.000 999411 Confirmed 18 Confirmed 0.00 0.01
1 NSR 11 Providing ,fixing , testing and commissioning of Water lift pumps set 2 no’s (1 Working + 1 Standby) to OHT Centrifugal End Suction Close Couple pumps of Water Flow Rate of each pump 5m3/hr with the head of 35 MWC adequate the casing shall be cast iron and impeller shall be Stainless steel the pump 4kw capacity shall be provided by manufacturer at suitable head to work on 3Ph, 50Hz, 400/440V with necessary unions, flanges, foundation bolts, RCC footing in 1:2:4 etc. complete.This rate shall inclussive of control panel for flushing water supply system comprising of filter feed pump for water treatment plant, de watering pumps, for back wash etc., located at pump room suitable control switches with energy meter (three phase kw/hr meter 32 amps with reverse rotation stop, class 1.0 flush mounting) indoor wall mounting type with auto change over switch for changing over from EB to DG supply and change over switch for pump change over, including dry run protection. The electrical control panel comprising of all accessories such as PLCs, pressure switches, pressure transducers, control wiring & End terminations , earth strip of GI 25 x 3 mm,cable tray and any other necessary imports etc.. Set 2.000 998719 Confirmed 18 Confirmed 0.00 0.01
a Application: : Domestic & Flushing water distribution
Duty : 5 cum/hr
Nos. of Pumps : (1 working + 1 stand by)
a Pressure switch Nos 2.000
b Pressure guage Nos 2.000
c Control panel Nos 1.000
d Control cable as per OEM Rmt 40.000
e 65 mm Strainer Nos 1.000
f 50 mm NRV Nos 1.000
g 50 MM BFV Nos 1.000
h 65 mm BFV Nos 1.000
i Cable tray Rmt 40.000
2 NSR 12 Providing ,fixing , testing and commissioning of Submersible type storm Water lift pumps set 2 no’s (1 Working + 1 Standby) Close Couple pumps of Water Flow Rate of each pump 10 cum/hr with the head of 15 MWC adequate the casing shall be cast iron and impeller shall be Stainless steel the pump HP capacity shall be provided by manufacturer at suitable head to work on 3Ph, 50Hz, 400/440V with necessary unions, flanges, foundation bolts, RCC footing in 1:2:4 etc. complete. Vendor shall consider he electrical control panel comprising of all accessories such as MCB ,isolation valve,non return valve, pressure switches, pressure transducers, control wiring & End terminations , earth strip of GI 25 x 3 mm,cable tray and any other necessary imports etc. complete.Pump room pumps Set 2.000 998719 Confirmed 18 Confirmed 0.00 0.01
a Discharge elbow Nos 4.000
b Pressure switch Nos 2.000
c Pressure guage Nos 2.000
d Control panel Nos 1.000
e Control cable as per OEM Rmt 40.000
f 50 mm NRV Nos 1.000
g 50 MM BFV Nos 1.000
h Cable tray Rmt 40.000
3 NSR 13 Supplying, installing, testing and commissioning approved make water level controller with alarm for the Underground Sump. The quoted rate shall include for necessary wiring in PVC conduit between the control panel, underground sump and overhead tank.(length of cable approx. 60 mts. Nos 5.000 998719 Confirmed 18 Confirmed 0.00 0.01
4 NSR 14 Excavation in all types of soil . including forming bottom surface to required level, refilling selected excavated earth around the pipe in layers 150mm thick, watering, consolidating and disposing off the surplus earth with in the site with a lead as directed by the site engineer complete.
a Depth upto 2.0 M. Cum 300.000 998719 Confirmed 18 Confirmed 0.00 0.01
F WATER TREATMENT PLANT - 3.0 m3/hr
1 NSR 16 Supply, installation, testing and commissioning of pressure sand filter of FRP construction with necessary equipment complete with MPV piping, valves, suitable supports for mounting, pressure guage, orifice plate etc.,complete as per the detailed specification for the efficient working of system. The maximum working Pressure shall be 3.5Kg/Sqcm and dia is 500 mm and hieht 1800 mm
a (a)Capacity : 3.0 cum /hr each 1.000 999411 Confirmed 18 Confirmed 0.00 0.01
2 NSR 17 Supply, installation, testing and commissioning of activated carbon filter of FRP construction with necessary equipment complete with MBV piping, valves, suitable supports for mounting, pressure guage, orifice plate etc.,complete as per the detailed specification for the efficient working of system. The maximum working Pressure shall be 3.5Kg/Sqcm and dia is 500mm and hieht 1800 mm
a (a)Capacity : 3.0 cum /hr each 1.000 999411 Confirmed 18 Confirmed 0.00 0.01
3 NSR 18 Supply of monobloc pumps for transfering the raw water to the filters 5 m3/hr @ 12- 15 mts head .
a Raw water to Treated water sump Lot 1.000 999411 Confirmed 18 Confirmed 0.00 0.01
4 NSR 19 Supplying, installing, testing and commissioning approved make water softener with necessary Ancillary equipment complete with piping, valves ejector, orifice plate, salt satuator made of corrosion resistant material and hardness testing kit etc., complete as per detailed specification for the efficient working of the system. Consider a Total hardness of 500 ppm, hardness required for treated water less than 150 ppm Caco3.Max. working pressure = 3.5Kg/Sqcm. 3 m3/hr Size dia is 600 mm and height1800 mm, 1000 L Capacity of HDPE - Salt Regeneration tank and OBR OF 130 cum @ 500 PPM Hardness.
a Capacity : shall be driven by WTP vendor based on the water hardness paramenter each 1.000 999411 Confirmed 18 Confirmed 0.00 0.01
5 NSR 20 On line Metered Chlorine Dosing system including a 100L capacity storage tank etc., complete. each 1.000 999411 Confirmed 18 Confirmed 0.00 0.01
6 NSR 21 Supply, installation, testing and commissioning of inter unit piping with necessary flanges, bolts, nuts, neoprene gaskets, welding wherever necessary, with necessary control valves, non return valves etc and with one coat of primer and two coats of approved enamel paint etc., complete. lot 1.000 999411 Confirmed 18 Confirmed 0.00 0.01
7 NSR 22 Supply, installation, testing and commissioning of Level Switch for pump control each 1.000 999411 Confirmed 18 Confirmed 0.00 0.01
8 NSR 23 Electrical works related for the above items including cabling, Panel , end terminations,laying in cable trays from connected loads upto the panel board etc.,complete. No 1.000 999411 Confirmed 18 Confirmed 0.00 0.01
Cable tray - 40 Rmt
9 NSR 24 Installing, testing and commissioning plant, inter unit piping with necessary flanges, bolts, nuts, neoprene gaskets, welding wherever necessary, with necessary control valves, non return valves ,required corecut & sleeves In RCC wall etc and with one coat of primer and two coats of approved enamel paint etc., complete. Lot 1.000 999411 Confirmed 18 Confirmed 0.00 0.01
1 NSR 25 BAR SCREEN
a Providing, fixing, testing and commissioning of bar screen consisting of 1nos. Of fine screen and one number coarse shall be provided in front of the intake works, so as to exclude the large sized particles with associated set of guide angles in MS flat of 6.0 mm thick and 50 mm wide kept inclined at 45 degree to the horizontal at 40mm c/c with one no. hand rack in GI. bar rack fabricated from SS-304 bars to the width of the screen chamber with a racking arm for manual operation Nos 1.000 Confirmed 18 Confirmed 0.00 0.01
Providing, fixing, testing and commissioning of SEWAGE transfer pumps (Submersible type). The pump shall be coupled to the 2/4/6 HP. electrical motor, mounted on a common base frame as per technical specifications
a a RAW SEWAGE TRANFER PUMP - EQT to SBR TANK Nos. 2.000 995462 Confirmed 18 Confirmed 0.00 0.01
Discharge capacity cum/hr. 3.000
Total delivery head m 10.000
No of pumps required Nos. 2.000
Working pumps Nos. 1.000
Standby Pumps Nos. 1.000
b b SLUDGE TRANSFER PUMP Nos. 1.000 995462 Confirmed 18 Confirmed 0.00 0.01
Discharge capacity cum/hr. 5.000
Total delivery head m 10.000
No of pumps required Nos. 2.000
Working pumps Nos. 1.000
Standby Pumps Nos. 1.000
c c FILTER FEED PUMP Nos. 2.000 995462 Confirmed 18 Confirmed 0.00 0.01
Discharge capacity cum/hr. 4.000
Total delivery head m 35.000
No of pumps required Nos. 2.000
Working pumps Nos. 1.000
Standby Pumps Nos. 1.000
3 NSR 27 AIR BLOWERS
Providing and fixing in position ring blowers of suitable discharge capacity as mentioned with suitable TEFC motor, the blower and motor mounted on common blasé plate, air filter, pressure gauges, safety valve and NRV on discharge side etc., complete .
a Blower for SBR Nos. 2.000 995468 Confirmed 18 Confirmed 0.00 0.01
Air discharge capacity Cum./Hr. 50.000
Discharge pressure ksc 0.500
Total No. of blowers Nos. 2.000
No. of working blowers Nos. 1.000
No. of stand by blowers Nos. 1.000
Make: USHA/ LEINTZ/KAY/ EVEREST/EQ
4 NSR 28 COARSE BUBBLE DIFFUSERS
a Providing, fixing, testing and commissioning of Coarse bubble diffuser with Tubular Type 80mm dia x 800 mm long long of uPVC pipe grid with necessary orifices uPVC pipe of 6.0 kg/sq cm pressure rating with removable deflector to provide clog-free oxygen for equilization tank and reactor tank. lot 1.000 995468 Confirmed 18 Confirmed 0.00 0.01
Make: MM Aqua / SC / EQ
5 NSR 29 FINE BUBBLE DIFFUSERS IN SBR TANKS
a Providing and fixing non-buoyant fine pore air bubble diffusers with necessary piping and support grid of 90mm dia, 1m long with EPDM membrane. The support frame retained by two hose clamps fitted to pipe lateral by PVC TEE and spectrum saddle arrangement in each SBR tank & Treated water reuse tank., complete . lot 1.000 995468 Confirmed 18 Confirmed 0.00 0.01
6 NSR 30 Supply, installation, testing and commissioning of inter unit piping with necessary flanges, bolts, nuts, neoprene gaskets, welding wherever necessary, with necessary control valves, non return valves etc and with one coat of primer and two coats of approved enamel paint etc., complete. Lot 1.000 995468 Confirmed 18 Confirmed 0.00 0.01
7 NSR 31 PRESSURE SAND FILTER
a Providing and fixing Pressure sand filter in FRP of sizes of 1200 specification made of appropriate shell & dish ends suitable for 10 kg/sq.cm. test pressure and 5 kg/sq.cm. working pressure with suitable valve battery / Multiport valve of suitable dia having a filtration rate of 18cum/sqm/hr. with initial charge silica filter media depth shall be atlest 1000mm bed depth , pressure gauge with isolation valves on inlet, outlet, air release valve, strainer for distribution, collection etc., complete Nos. 1.000 995468 Confirmed 18 Confirmed 0.00 0.01
Flow rate Cum/hr. 4.000
Diameter of vessel m 0.600
Height of tank on HOS m 1.200
8 NSR 32 ACTIVATED CARBON FILTER
a Providing and fixing Activated carbon filter in FRP of sizes of 1200 specification made of appropriate shell & dish ends suitable for 10 kg/sq.cm. test pressure and 5 kg/sq.cm. working pressure with suitable valve battery / Multiport valve of suitable dia having a filtration rate of 18 cum/sqm/hr. with initial charge Iodine 800 grade GAC media , pressure gauge with isolation valves on inlet, outlet, air release valve, strainer for distribution, collection etc., complete. Nos. 1.000 995468 Confirmed 18 Confirmed 0.00 0.01
Flow rate Cum/hr. 4.000
Diameter of vessel m 0.600
Height of tank on HOS m 1.200
9 NSR 33 CHLORINE DOSING SYSTEM FOR FLUSHING WATER
a Providing and fixing Sodium hypo chlorite solution dosing system with a metered dosing pump with required storage capacity at 2 to 5 PPM dosing rate as required etc., complete as per standard specification. Set 1.000 995462 Confirmed 18 Confirmed 0.00 0.01
Flow rate of Dosing pump cum/hr. 5.000
10 NSR 34 Electrical works
Providing the following electrical works necessary for suitable operation of the plant as per specification, design & relevant standards etc., complete as per specification .
a a MCC.Panel suitable for 415V, 3 phase, 4 wire, 50Hz distribution system. The panel shall be Wall Mounting / Floor Mounting type, sheet metal enclosed, flush front with aluminium busbars, earthing point etc. The incoming and the outgoing feeder breakers, switch fuse units, change over switches, indicating lamps, meters etc. shall be accommodated in a modular multi tier arrangement with independent starters, isolators, and indicator lamps for all equipments. 1 1.000 995461 Confirmed 18 Confirmed 0.00 0.01
11 NSR 35 COMMISSIONING CHARGES
a Deploying necessary trained personal including cost of necessary chemicals, consumable required for commissioning the system. Lot 1.000 995462 Confirmed 18 Confirmed 0.00 0.01
12 NSR 36 Plant Piping with CPVC pipes with fittings and approved make valves, gauges, Paddle flanges and instrumentation etc., Lot 1.000 995462 Confirmed 18 Confirmed 0.00 0.01
TOTAL 0.17 0.00 #REF!
# In case the bidder leaves the cell for confirmation of the SAC/HSN code and/or GST rate “blank”, the SAC/HSN code and corresponding GST rate indicated by the Employer shall be deemed to be the one confirmed by the Bidder.
Date : Printed Name :
Place : Designation :
Specification No.: ODP/BB/C&M-3575/OT-24/RFx No. 5002003243/23-24 Schedule - 1D Solar Works)
Construction of a Control Centre Building for OPTCL STAMS (State Transmission Asset Management System) Project by POWERGRID under Consultancy Services to OPTCL As per Lum-sum
(SCHEDULE OF RATES AND PRICES ) AS per Percent
As per lum-sum on Sch-3
Bidder’s Name and Address To: As per Percent on Sch-3
#REF! Sr. GM(C&M) Multipackage lum-sum
Name: POWER GRID CORPORATION OF INDIA LIMITED, Multipackage on Percent
Address: ODISHA PROJECTS Total Discount
PLOT NO.-4, UNIT-41, NILADRI VIHAR
CHANDRASHEKHARPUR, BHUBANESWAR-751021
SOLAR WORKS All Prices are in Indian Rupees.
SI. No. Service Activity Number DSR 2023/NSR Item Description Unit Qty. SAC/HSN Codes Whether SAC/HSN in column ‘4’ is confirmed. If not indicate applicable the SAC/HSN # Rate of GST applicable ( in %) Select from Drop-down menu. Whether rate of GST in column ‘6’ is confirmed. If not indicate applicable rate of GST # Unit Rate (excluding GST) but including labour welfare cess & Freight (if any) GST Amount Amount (Excluding GST) but including labour welfare cess & freight (if any) Unit Erection Charges Total Erection Charges
1 NSR 402 Supply and Installation of 400 watt monocrystalline , module mounting structer (GI) 60 KW inverter complete in all respeact and as directed by Engineer-in- Charge. EACH 1.000 995468 Confirmed 18 Confirmed 0.00 0.01
TOTAL 0.00 0.00 #REF!
# In case the bidder leaves the cell for confirmation of the SAC/HSN code and/or GST rate “blank”, the SAC/HSN code and corresponding GST rate indicated by the Employer shall be deemed to be the one confirmed by the Bidder.
Date : Printed Name :
Place : Designation :
Specification No.: ODP/BB/C&M-3575/OT-24/RFx No. 5002003243/23-24 Schedule - 1E (FIRE DETECTION & PROTECTION WORKS)
Construction of a Control Centre Building for OPTCL STAMS (State Transmission Asset Management System) Project by POWERGRID under Consultancy Services to OPTCL As per Lum-sum
(SCHEDULE OF RATES AND PRICES ) AS per Percent
As per lum-sum on Sch-3
Bidder’s Name and Address To: As per Percent on Sch-3
#REF! Sr. GM(C&M) Multipackage lum-sum
Name: POWER GRID CORPORATION OF INDIA LIMITED, Multipackage on Percent
Address: ODISHA PROJECTS Total Discount
PLOT NO.-4, UNIT-41, NILADRI VIHAR
CHANDRASHEKHARPUR, BHUBANESWAR-751021
FIRE DETECTION & PROTECTION WORKS All Prices are in Indian Rupees.
SI. No. Service Activity Number DSR 2023/NSR Item Description Unit Qty. SAC/HSN Codes Whether SAC/HSN in column ‘4’ is confirmed. If not indicate applicable the SAC/HSN # Rate of GST applicable ( in %) Select from Drop-down menu. Whether rate of GST in column ‘6’ is confirmed. If not indicate applicable rate of GST # Unit Rate (excluding GST) but including labour welfare cess & Freight (if any) GST Amount Amount (Excluding GST) but including labour welfare cess & freight (if any) Unit Erection Charges Total Erection Charges
FIRE DETECTION & PROTECTION WORKS
A Fire Alarm system
1 17.2.1 Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel,central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5 % V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance freebatteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamlessintegration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications.
a 17.2.1.2 Two Loop Panel. each 1.000 995461 Confirmed 18 Confirmed 0.00 0.01
2 17.2.4 Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required. each 200.000 995461 Confirmed 18 Confirmed 0.00 0.01
3 17.2.5 Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required. each 100.000 995461 Confirmed 18 Confirmed 0.00 0.01
5 17.2.7 Supplying, installation, testing & commissioning of fault isolator complete with base as required. each 10.000 995461 Confirmed 18 Confirmed 0.00 0.01
6 17.2.10 Supplying, installation, testing & commissioning of addressable fire control module complete as required. each 15.000 995461 Confirmed 18 Confirmed 0.00 0.01
7 17.2.11 Supplying, installation, testing & commissioning of addressable phone control module complete as required. each 10.000 995461 Confirmed 18 Confirmed 0.00 0.01
8 17.2.12 Supplying, installation, testing & commissioning of addressable beam detector with short circuit isolator (inbuilt or seperate) complete with emitter and receiver including connections with remote test features etc complete as required. each 10.000 995461 Confirmed 18 Confirmed 0.00 0.01
9 17.2.13 Supplying, installation, testing & commissioning of intelligent addressable duct detector including suitable Photo detector complete with base as required. each 16.000 995461 Confirmed 18 Confirmed 0.00 0.01
10 17.2.14 Supplying, installation, testing & commissioning of addressable manual call point complete as required. each 10.000 995461 Confirmed 18 Confirmed 0.00 0.01
11 17.2.14 Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required. each 10.000 995461 Confirmed 18 Confirmed 0.00 0.01
12 17.2.17 Supplying, installation, testing & commissioning of fire fighter telephone handset complete as required. each 10.000 995461 Confirmed 18 Confirmed 0.00 0.01
13 17.2.19 Supplying, installation, testing & commissioning of fire fighter phone jack complete as required each 10.000 995461 Confirmed 18 Confirmed 0.00 0.01
15 17.5.2 Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. rmt 3000.000 995461 Confirmed 18 Confirmed 0.00 0.01
16 17.5.4 Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required. Metre 300.000 995461 Confirmed 18 Confirmed 0.00 0.01
17 18.1 Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required :
a a Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520.
b b Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325.
c c M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.
d d Suitable cement concrete foundation duly plastered with anti vibration pads.
18.1.5 2280 lpm at 70 m Head set 1.000 995461 Confirmed 18 Confirmed 0.00 0.01
18 18.2 Supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel Driven Pump)
Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520.
Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required.
M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required.
Suitable cement concrete foundation duly plastered and with anti vibration pads.
a 18.2.5 2280 lpm at 70 m Head Set 1.000 995454 Confirmed 18 Confirmed 0.00 0.01
19 18.3 Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump)
Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520.
Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS : 325.
M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required
Suitable cement concrete foundation duly plastered and with anti vibration pads.
a 18.3.2 180 lpm at 70 m Head set 1.000 995461 Confirmed 18 Confirmed 0.00 0.01
20 18.5 Fabrication, supply, Insallation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, inter- connection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per CPWD specification with following in coming and Outgoings, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required : set 1.000 995461 Confirmed 18 Confirmed 0.00 0.01
a 18.5.2 INCOMING
400A, 50kA 4 Pole MCCB, Ics=100% Icu rating
Digital Voltmeter 0-500V with selector switch
Digital Ammeter (0-400 A) with selector swtich & CTs etc.
LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps
Set of Copper Bus Bar 500A
( Note : All outgoing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicating lamps)
200 A, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 75 hp pump with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation.
100 A, 50kA TPN MCCB, Ics=100% Icu, with suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation
Diesel Engine Control
Control for diesel engine comprising -
Automatic/Manual selctor switch & 3 attempt starting device, timers and relays as required, push buttons, start/stop in manual mode
Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indication
Battery charger suitbale for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0- 20 A DC Ammeter
All standard relays and accessories for automatic operation of diesel engine
System Controller
Designing, Supply,commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specifications.
b NSR 1 Providing ,fixing , testing and commissioning of Fire duct Shutter fabricated out of M.S sheet and frame, door (SWG 16) and powder coated of approved red color both inside and out side. The size shall be 900mm x 1200 mm min. & fixed with 6 mm thick Glass, and key with suitable Rubber beading and Locking arrangement as per the tender drawings. Each 10.000 995461 Confirmed 18 Confirmed 0.00 0.01
21 NSR 2 Supply and Transportation of XLPE/PVC insulated & PVC sheathed unarmoured control cables of 1.1 KV grade with copper conductor as per IS 7098 Part-I -1988 etc complete
a a 12 C x 2.5 Sqmm. Copper cable Diesel engines rmt 30.000 995461 Confirmed 18 Confirmed 0.00 0.01
b b 4 C x 16 Sqmm. Aluminum cable Jockey pumps rmt 30.000 995462 Confirmed 18 Confirmed 0.00 0.01
c c 2 C x 2.5 Sqmm.Copper cable for Instrumentation rmt 90.000 995461 Confirmed 18 Confirmed 0.00 0.01
d d 3.5C x 90 sq.mm Aluminum cable for main pumps rmt 60.000 995462 Confirmed 18 Confirmed 0.00 0.01
22 NSR 3 Supply and making end termination with heavy Alluminium lugs (pin/ ring type) as per IS specification duly crimped with crimping tool, PVC tape etc of following size Makes:Dowels/Jainson/Comet
a a up to 16 sq mm nos 10.000 995461 Confirmed 18 Confirmed 0.00 0.01
b b 16 to 120 Sq mm nos 60.000 995461 Confirmed 18 Confirmed 0.00 0.01
23 NSR 4 Supply,transporatation & installation of following sizes of Hot Dipped Galvanized Iron perforated cable trays without cover, including horizontal and vertical bends, reducers tees,cross members and other accessories as required and duly suspended from the ceiling/Wall with suspenders etc., complete
a a 100mm x 50mm x 1.6mm rmt 20.000 995461 Confirmed 18 Confirmed 0.00 0.01
b b 300mm x 50mm x 1.6mm rmt 30.000 995461 Confirmed 18 Confirmed 0.00 0.01
24 NSR 5 Supply and laying of following sizes Earth wire/Strip in horizontal /Vertical run in Ground/surface/Recess including, revitting,soldering,saddles,making connection etc as required
a 32 mm x 6mm Copper Flat(1.9 Kgs/Mtr) rmt 500.000 995461 Confirmed 18 Confirmed 0.00 0.01
25 NSR 6 Supply, installation, testing and commissioning of Bourden type, stainless steel dial type pressure gauge with isolation valve and pipe having calibration of 0-16 kg/cm2. each 6.000 995461 Confirmed 18 Confirmed 0.00 0.01
26 NSR 7 Providing ,fixing , testing and commissioning of Exhaust pipe of dia 150mm MS medium grade for Diesel engine with mineral wool insulation with aluminum cladding including necessary supports through shaft up to terrace level Rmt 25.000 995461 Confirmed 18 Confirmed 0.00 0.01
27 NSR 8 Supplying and fixing of hose cabinet of size 750mm X 600mm x 250mm made of No 16 gauge SWG CRCA sheet with 6mm thick glazed glass door including necessary locking arrangement suitable to accommodate 2 Nos 15 mtr long Hose pipe, 1 No branch pipe, mounted on wall OR raised brick platform and duly painted with Post office red externally and white internally with synthetic enamel paint complete in all respect, for external hydrant as required. NOS 4.000 995461 Confirmed 18 Confirmed 0.00 0.01
29 18.7 Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :
b 18.7.1 25 mm dia Rmt 900.000 995461 Confirmed 18 Confirmed 0.00 0.01
c 18.7.2 32 mm dia Rmt 600.000 995461 Confirmed 18 Confirmed 0.00 0.01
d 18.7.3 40 mm dia Rmt 400.000 995461 Confirmed 18 Confirmed 0.00 0.01
e 18.7.4 50 mm dia Rmt 150.000 995461 Confirmed 18 Confirmed 0.00 0.01
f 18.7.5 65 mm dia Rmt 100.000 995461 Confirmed 18 Confirmed 0.00 0.01
g 18.7.6 80 mm dia Rmt 120.000 995461 Confirmed 18 Confirmed 0.00 0.01
f 18.7.7 100 mm dia Rmt 150.000 995461 Confirmed 18 Confirmed 0.00 0.01
g 18.7.8 150 mm dia Rmt 150.000 995461 Confirmed 18 Confirmed 0.00 0.01
h 18.7.9 200 mm dia-wall thickness = 6.3 mm Rmt 12.000 995461 Confirmed 18 Confirmed 0.00 0.01
i 18.7.10 250 mm dia wall thickness = 6.3 mm Rmt 12.000 995461 Confirmed 18 Confirmed 0.00 0.01
30 NSR 9 Supplying and wrapping the anticorrosive material for buried pipes with coating of Primer and wrapping with 4 mm thick polymer corrosion resistant tape as per IS : 10221 with 15 mm overlap as per specificatios. rmt 220.000 995461 Confirmed 18 Confirmed 0.00 0.01
31 18.9 Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required :
a 18.9.1 Single headed Gunmetal Set 4.000 995461 Confirmed 18 Confirmed 0.00 0.01
32 18.11 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :
a 18.11.2 50mm dia Nos 5.000 995461 Confirmed 18 Confirmed 0.00 0.01
b 18.11.4 80 mm dia Nos 1.000 995461 Confirmed 18 Confirmed 0.00 0.01
c 18.11.5 100 mm dia Nos 5.000 995461 Confirmed 18 Confirmed 0.00 0.01
d 18.11.6 150 mm dia Nos 8.000 995461 Confirmed 18 Confirmed 0.00 0.01
33 18.11 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :
a 18.11.4 80mm dia Nos 1.000 995461 Confirmed 18 Confirmed 0.00 0.01
b 18.11.5 100mm dia Nos 1.000 995461 Confirmed 18 Confirmed 0.00 0.01
c 18.11.6 150mm dia Nos 6.000 995461 Confirmed 18 Confirmed 0.00 0.01
d 18.11.7 200mm dia Nos 2.000 995461 Confirmed 18 Confirmed 0.00 0.01
e 18.11.8 250mm dia Nos 1.000 995461 Confirmed 18 Confirmed 0.00 0.01
34 18.14 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required
b 18.14.4 80mm dia Nos 1.000 995461 Confirmed 18 Confirmed 0.00 0.01
c 18.14.7 150mm dia Nos 3.000 995461 Confirmed 18 Confirmed 0.00 0.01
35 18.15 Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.
b 18.15.3 150mm dia Rmt 1.000 995461 Confirmed 18 Confirmed 0.00 0.01
c 18.15.5 250mm dia Rmt 1.000 995461 Confirmed 18 Confirmed 0.00 0.01
36 18.16 Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :
a 18.16.1 Gun Metal set 10.000 995461 Confirmed 18 Confirmed 0.00 0.01
37 18.17 Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required.
20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585
20 mm nominal internal dia gun metal globe valve & nozzle.
Drum and brackets for fixing the equipmets on wall.
Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.
a 18.17.2 40m set 10.000 995461 Confirmed 18 Confirmed 0.00 0.01
39 18.18 Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required
a 18.18.1 Gun metal Nos 10.000 995461 Confirmed 18 Confirmed 0.00 0.01
40 18.19 Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required :
a 18.19.1 2 way - 100 mm dia M.S. Pipe Nos 1.000 995462 Confirmed 18 Confirmed 0.00 0.01
b 18.19.2 4 way - 150 mm dia M.S. Pipe Nos 1.000 995462 Confirmed 18 Confirmed 0.00 0.01
41 18.2 Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required. set 1.000 995461 Confirmed 18 Confirmed 0.00 0.01
42 18.22 Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required. each 3.000 995461 Confirmed 18 Confirmed 0.00 0.01
43 18.21 Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories
a 18.21.1 Pendent Sprinkler each 694.444 995461 Confirmed 18 Confirmed 0.00 0.01
44 18.22 Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required. each 5.000 995462 Confirmed 18 Confirmed 0.00 0.01
45 18.23 Providing & fixing flow switch in following sizes M.S. pipe including connection etc as required
a 18.23.1 100 mm each 5.000 995462 Confirmed 18 Confirmed 0.00 0.01
46 18.24 Providing, fixing, testing & commissioning of installation control valve of cast iron body, brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate, gasket etc of follwing sizes as required
a 18.24.3 150mm dia set 1.000 995461 Confirmed 18 Confirmed 0.00 0.01
47 18.25 Supplying, installation, testing & commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required.
a 18.25.3 1200 mm each 500.000 Confirmed 18 Confirmed 0.00 0.01
48 NSR 10 Supply and fixing of Co2 type Fire Extinguishers 4.5 Kg capacity confirming to IS 2878 made from ISI marked steam less cylinder confirming to IS:7285 & CE certified and fitted with ISI marked controlled valve confirming to IS:3224, high pressure 1 Mtr discharge hose & horn complete with initial gas charged with carrying handle with wheels and wall mounting bracket. Squeeze lever discharge, used un-used indicator, Aphoxy coated paint (Red) with 93% gloss with 2 years warrantyIncluding transportation, all taxes and all labour charges etc complete. each 10.000 995461 Confirmed 18 Confirmed 0.00 0.01
49 NSR 11 Providing ,fixing , testing and commissioning of Portable AFFF Foam Type fire extinguisher 9 Lt Capacity, Stored Pressure Type with Pressure Gauge, hose and brackets etc .The discharge Range shall be minimum of 6 mtrs.The Internal Coating of Can shall be Epoxy Powder coating and External painted with Epoxy Polyester Powder coating .The thickness shall not less than 2mm made of Sheet metal.The Fire Extinguishers shall be ISI Approved as per IS 15683:2006.Vendor shall consider the suitable signages along with the extinguishers. each 4.000 995461 Confirmed 18 Confirmed 0.00 0.01
50 NSR 12 Supply and fixing of ISI mark (IS:15683) Mono ammonium phosphate powder 90 (MAP) 6 Kg Fire extinguisher, stored pressure type, pressure gauge, gross wt. 9.4 kg, empty wt.3.4 kg, Discharge time minimum 13 sec, controllable discharge mechanism, range min. 4 mts applicable on classes A,B, C & electrically started fire, A rating -4 A, B rating -34 B, can construction: Deep drawn and Co2 mig welding, Valve construction: Forging & Machining, internal coating of can: Epoxy powder coating, External coating of Can:Epoxy polyster powder coating, sheet metal thickness:1.60mm, Helium leak detection tested with 5 years warranty Including transportation, all taxes and all labour charges etc complete. each 60.000 995461 Confirmed 18 Confirmed 0.00 0.01
51 NSR 13 Supply and fixing of 2Nos of 9 Ltrs capacity round bottom sand buckets along with bucket sand, Fire buckets with round bottom type enamel painted, white inside & red out side and letter FIRE inblack out side & Handle with mounting bracket. each 20.000 995461 Confirmed 18 Confirmed 0.00 0.01
52 NSR 14 Supply and fixing of Fire bucket stand fabricated by M.S. angles to install for Four numbers of buckets as per local fire officers standards. each 10.000 995461 Confirmed 18 Confirmed 0.00 0.01
53 NSR 15 Providing ,fixing , testing and commissioning of Portable waterType fire extinguisher 9 Lt Capacity, Stored Pressure Type with Pressure Gauge, hose and brackets etc .The discharge Range shall be minimum of 6 mtrs.The Internal Coating of Can shall be Epoxy Powder coating and External painted with Epoxy Polyester Powder coating .The thickness shall not less than 2mm made of Sheet metal.The Fire Extinguishers shall be ISI Approved as per IS 15683:2006.Vendor shall consider the suitable signages along with the extinguishers. each 4.000 995461 Confirmed 18 Confirmed 0.00 0.01
54 NSR 16 Excavation of trenches of 1500 x1000 mm for laying pipes up to 150mm dia. Including forming bottom surface to required level, refilling the trenches with selected excavated earth around the pipe in layers of 150mm thick, watering, consolidating. Quoted price inclusive of disposing off / Carting away the surplus earth out side the site to a dump yard acceptable local bodies or as directed by the site engineer with a lead of 300 mts. etc. complete.
a a Excavation in all kinds of soil Cum 100.000 995461 Confirmed 18 Confirmed 0.00 0.01
b b Cutting of Rock with chiseling Cum 5.000 995461 Confirmed 18 Confirmed 0.00 0.01
55 NSR 17 Providing and laying 30 cm diameter open jointed hume pipes with collars in rock-toe for drainage including cost of all materials, machinery, labour etc., complete with lead upto 1 km and all lifts. Rmt 30.000 995461 Confirmed 18 Confirmed 0.00 0.01
56 NSR 18 Providing ,fixing , testing and commissioning of PCC (1:2:4) pedestals / supports for Under ground / above ground pipes. Quoted rate shall inclusive of excavation ( if required ), chipping / chasing, shuttering, plastering ( if required) etc. complete. Cum 2.000 995461 Confirmed 18 Confirmed 0.00 0.01
57 NSR 19 Providing ,fixing , testing and commissioning of Sealing of shafts at all floor levels by using M.S. angle Iron frame around the shaft M.S. chequered plate of 6mm thick and PCC ( 100mm thick) of 1:2:4 on the plate for whole shaft area as per drawings and engineer - in - charge. FOR ALL MEP SERVICE SHAFTS Sq.mt 50.000 995461 Confirmed 18 Confirmed 0.00 0.01
58 NSR 20 Construction of valve chamber with 230 mm Brick masonry wall with best quality TM bricks & CM 1:4,on a PCC 1:5;10 bed of 150 mm thcik.The wall shall be plastered internally smooth in CM 1:3, water proofing as required and externally rough plastered with sponge finish, including curing. The chamber shall be provided with M.S 8 mm thick plate fabricated top cover in leaves with necessary hinges and locking arrangement. The size of the chamber shall be 1200mm x 1200mm x1500mm in depth. Nos 1.000 995461 Confirmed 18 Confirmed 0.00 0.01
59 NSR 21 Supply, installation, testing and commissioning of 25 / 20mm dia Air Release Valve Nos 2.000 995461 Confirmed 18 Confirmed 0.00 0.01
60 NSR 22 Supply, installation, testing and commissioning of 25mm dia Ball valve Nos 2.000 995461 Confirmed 18 Confirmed 0.00 0.01
Providing ,fixing of in position the following type of sign boards made out of 3mm thick "Opaque" PVC foam board with computer cut, PVC Non-reflective self adhesive vinyle painted foam board, complete with mirror fasteners.
61 NSR 23 A sign shall read “IN CASE OF FIRE, USE STAIRS UNLESS INSTRUCTED OTHERWISE”. The lettering shall be at least 12.5 mm block letters in red and white background. Such lettering shall be properly spaced to provide good legibility. The sign shall be at least 250 mm x 300 mm, where the diagram is also incorporated in it and 62.5 mm x 250 mm where the diagram is omitted. In the latter case, the diagram sign shall be at least 200 mm x 300 mm. The sign shall be located directly above a call-button and squarely attached to the wall or partition. The top of the sign shall not be above 2 m from the floor level. Nos 10.000 995461 Confirmed 18 Confirmed 0.00 0.01
62 NSR 24 Fire exit signage at Each stairway and each elevator back shall be identified by an alphabetical letter. A sign indicating the letter of identification shall be posted and maintained at each elevator landing and on the side of the stairway door from which egress is to be made.The lettering on the sign shall be at least 75 mm high, of bold type and of contrasting colour from the background Nos 10.000 995461 Confirmed 18 Confirmed 0.00 0.01
63 NSR 25 A sign shall be posted and maintained within each stair enclosure on every floor, indicating the number of the floors.The numerals shall be of bold type and at least 75 mm high. The numerals and background shall be in contrasting colors. The sign shall be securely attached to the stair side of the door. Nos 10.000 995461 Confirmed 18 Confirmed 0.00 0.01
64 NSR 26 Stair Re-entry Signs sign shall be posted and maintained on each floor within each stairway and on the occupancy side of the stairway where required, indicating whether re-entry is provided into the building and the floor where such re-entry is provided.The lettering and numerals of the signs shall be at least 12.5 mm high of bold type. The lettering and background shall be of contrasting colours and the signs shall be securely attached approximately 1.5 m above the floor level. Nos 10.000 995461 Confirmed 18 Confirmed 0.00 0.01
65 NSR 26 Fire order board should contain the following matter on 3mm thick "Opaque" PVC foam board of computerized cut, PVC Non-reflective self adhesive vinyle painted foam board of 3' x 4'. 1. Alert the security at security room by actuating manual call point located at strategic locations. 2. Evacuate the occupants by using fire exits and emergency exits only and assemble at various assembly points. 3. If possible try to extinguish the fire by using nearest / suitable portable extinguisher or water from nearest wet riser. 4. Be calm and do not give any room from panic, walk, do not run. 5. If you encounter serious difficulty in evacuation, flat and try to attract attention of rescue team. Nos 1.000 995461 Confirmed 18 Confirmed 0.00 0.01
66 NSR 28 Action by security/reception upon receipt of information through fire alarm or fire detectors or by using public address system. 1. Alert the occupants by using public address system. 2. Inform fire control through any one of the following phone numbers: 101 /(local numbers) 3. Refer evacuation plan from evacuating standard people. 4. Guide the fire force, on their arrival to the seat of fire. 5. In case of the casualties, call ambulance by dialing number 108. 6. Phone : ----------------------- 7. Fax : ---------------------------- Nos 1.000 995461 Confirmed 18 Confirmed 0.00 0.01
67 NSR 29 Providing ,fixing , testing and commissioning of Rosette plate and shall be fabricated by SS 304 plate of 2mm thick and sample, as approved by architects / clients. nos 500.000 995461 Confirmed 18 Confirmed 0.00 0.01
TOTAL 0.16 0.00 #REF!
# In case the bidder leaves the cell for confirmation of the SAC/HSN code and/or GST rate “blank”, the SAC/HSN code and corresponding GST rate indicated by the Employer shall be deemed to be the one confirmed by the Bidder.
Date : Printed Name :
Place : Designation :
Specification No.: ODP/BB/C&M-3575/OT-24/RFx No. 5002003243/23-24 Schedule - 1F (SINORIX CO2 & HFC 227ea (42BAR) GAS BASED FIRE SUPPRESSION SYSTEM)
Construction of a Control Centre Building for OPTCL STAMS (State Transmission Asset Management System) Project by POWERGRID under Consultancy Services to OPTCL As per Lum-sum
(SCHEDULE OF RATES AND PRICES ) AS per Percent
As per lum-sum on Sch-3
Bidder’s Name and Address To: As per Percent on Sch-3
#REF! Sr. GM(C&M) Multipackage lum-sum
Name: POWER GRID CORPORATION OF INDIA LIMITED, Multipackage on Percent
Address: ODISHA PROJECTS Total Discount
PLOT NO.-4, UNIT-41, NILADRI VIHAR
CHANDRASHEKHARPUR, BHUBANESWAR-751021
SINORIX CO2 & HFC 227ea (42BAR) GAS BASED FIRE SUPPRESSION SYSTEM All Prices are in Indian Rupees.
SI. No. Service Activity Number DSR 2023/NSR Item Description Unit Qty. SAC/HSN Codes Whether SAC/HSN in column ‘4’ is confirmed. If not indicate applicable the SAC/HSN # Rate of GST applicable ( in %) Select from Drop-down menu. Whether rate of GST in column ‘6’ is confirmed. If not indicate applicable rate of GST # Unit Rate (excluding GST) but including labour welfare cess & Freight (if any) GST Amount Amount (Excluding GST) but including labour welfare cess & freight (if any) Unit Erection Charges Total Erection Charges
SINORIX CO2 & HFC 227ea (42BAR) GAS BASED FIRE SUPPRESSION SYSTEM
1 140.0 Ltrs. Seamless CCOE Cylinder Nos. 2.000 999126 Confirmed 18 Confirmed 0.00 0.01
2 Sinorix VSB 33 Valve Nos. 2.000 999126 Confirmed 18 Confirmed 0.00 0.01
3 Sinorix 227ea/HFC 227ea agent Kgs. 280.000 999126 Confirmed 18 Confirmed 0.00 0.01
4 Pr. Guage + Low Pr. Supervisory Switch (PRESSCODEM 60) Nos. 2.000 999126 Confirmed 18 Confirmed 0.00 0.01
5 Electromagnetic Actuator (DEMADEM) Nos. 1.000 999126 Confirmed 18 Confirmed 0.00 0.01
6 Pneumatic Actuator (CP 16) Nos. 2.000 999126 Confirmed 18 Confirmed 0.00 0.01
7 Flexible Discharge Hose (FRF 33) Nos. 2.000 999126 Confirmed 18 Confirmed 0.00 0.01
8 Flexible Actuation Hose (FLEJIC) Nos. 3.000 999126 Confirmed 18 Confirmed 0.00 0.01
9 Manual Actuator (CM 16) Nos. 1.000 999126 Confirmed 18 Confirmed 0.00 0.01
10 Tee - 1 Nos (TEJIC) Nos. 2.000 999126 Confirmed 18 Confirmed 0.00 0.01
11 Elbow - 1 Nos (EQJIC) Nos. 1.000 999126 Confirmed 18 Confirmed 0.00 0.01
12 Check Valve (CRAF33) Nos. 2.000 999126 Confirmed 18 Confirmed 0.00 0.01
13 Nozzles (BUCEFA / BFFP) Nos. 2.000 999126 Confirmed 18 Confirmed 0.00 0.01
14 Warning Sign Board Nos. 1.000 999126 Confirmed 18 Confirmed 0.00 0.01
15 Wall Mount Cylinder Bracket Nos. 4.000 999126 Confirmed 18 Confirmed 0.00 0.01
16 Discharge Pressure Switch Nos. 1.000 999126 Confirmed 18 Confirmed 0.00 0.01
17 Supply Installation Testing & Commissioning of seamless pipes SCH40 and special threaded fittings with necessary angle / Hitech supports with anchore fastners including paiting of 2 coats of primer with one coat of signal red paint & Nitrogen pressure testing Of installed Piping. Lot. 1.000 999126 Confirmed 18 Confirmed 0.00 0.01
18 Supply, Installation, Testing and Commissioning of Fabricated cylinder manifold with supports & stand with required accessories for cylinders Lot. 1.000 999126 Confirmed 18 Confirmed 0.00 0.01
Conventional Gas Release System
19 2-Zone Conventional Gas Release Panel Nos. 1.000 999126 Confirmed 18 Confirmed 0.00 0.01
20 Conventional Multisensor Detector with base Nos. 8.000 999126 Confirmed 18 Confirmed 0.00 0.01
22 ABS type Manual Call Point with flop - Agent Release Switch Nos. 1.000 999126 Confirmed 18 Confirmed 0.00 0.01
23 ABS type Manual Call Point with flop - Abort Switch Nos. 1.000 999126 Confirmed 18 Confirmed 0.00 0.01
24 ABS Sounder cum strobe - 24V, 85 db Nos. 1.000 999126 Confirmed 18 Confirmed 0.00 0.01
25 LED Warning Signages Nos. 1.000 999126 Confirmed 18 Confirmed 0.00 0.01
26 Supply & laying of 2C x 1.5 sqmm FRLS armoured copper cable (Approx. Qty) quoting rate only exact qty will be get to known on the approved Shop drawings Mtrs. 200.000 999126 Confirmed 18 Confirmed 0.00 0.01
27 Commissioning charges Lot. 1.000 999126 Confirmed 18 Confirmed 0.00 0.01
TOTAL 0.05 0.00 #REF!
# In case the bidder leaves the cell for confirmation of the SAC/HSN code and/or GST rate “blank”, the SAC/HSN code and corresponding GST rate indicated by the Employer shall be deemed to be the one confirmed by the Bidder.
Date : Printed Name :
Place : Designation :
Specification No.: ODP/BB/C&M-3575/OT-24/RFx No. 5002003243/23-24 Schedule - 1G (ACCESS CONTROL SYSTEM)
Construction of a Control Centre Building for OPTCL STAMS (State Transmission Asset Management System) Project by POWERGRID under Consultancy Services to OPTCL As per Lum-sum
(SCHEDULE OF RATES AND PRICES ) AS per Percent
As per lum-sum on Sch-3
Bidder’s Name and Address To: As per Percent on Sch-3
#REF! Sr. GM(C&M) Multipackage lum-sum
Name: POWER GRID CORPORATION OF INDIA LIMITED, Multipackage on Percent
Address: ODISHA PROJECTS Total Discount
PLOT NO.-4, UNIT-41, NILADRI VIHAR
CHANDRASHEKHARPUR, BHUBANESWAR-751021
ACCESS CONTROL SYSTEM All Prices are in Indian Rupees.
SI. No. Service Activity Number DSR 2023/NSR Item Description Unit Qty. SAC/HSN Codes Whether SAC/HSN in column ‘4’ is confirmed. If not indicate applicable the SAC/HSN # Rate of GST applicable ( in %) Select from Drop-down menu. Whether rate of GST in column ‘6’ is confirmed. If not indicate applicable rate of GST # Unit Rate (excluding GST) but including labour welfare cess & Freight (if any) GST Amount Amount (Excluding GST) but including labour welfare cess & freight (if any) Unit Erection Charges Total Erection Charges
ACCESS CONTROL SYSTEM
1 Supply, Installation, testing and commissioning of Surface mounted Networkable multiprocessor controlled 4 reader controller capable of controlling multiple readers (IN/OUT) alongwith TCP/IP connectivity complete as per specifications. Control panel housed in MS Powder Coated Cabinet with Tamper Switch, Complete with power supply unit for Controllers & Magnetic Locks as per specification Nos. 10.000 998521 Confirmed 18 Confirmed 0.00 0.01
2 Supply, installation, testing and commissioning of Access Control Application Software for 128 Reader Capacity, and 1000 Card Holder Capacity, Nos. 1.000 998521 Confirmed 18 Confirmed 0.00 0.01
2.1 Supply, installation, testing and commissioning of Time & attendance software . Nos. 1.000 998521 Confirmed 18 Confirmed 0.00 0.01
3 SITC of Client workstation with 21" Monitor for Access Control System & Time & attendance system Nos. 2.000 998521 Confirmed 18 Confirmed 0.00 0.01
4 Supply, Installation, Testing & Commissioning of Biometric + Card reader Nos. 6.000 998521 Confirmed 18 Confirmed 0.00 0.01
5 Supply, installation, testing and commissioning of UL Listed Smart Card Reader with compatible support of weigand output, 13.56 MHz technology platform and complies with the ISO 15693 / 14443A standard for contact less smart card technology. Card reader must be configurable to read encrypted ISO14443A sectors using standard or custom read keys for Sign OUT Terminal. should be compatible with HID format cards. Encryption,All RF data transmission between the card and reader should be encrypted using a secure algorithm. Industry-standard encryption techniques and advanced key management systems should be used to avoid the risk of compromised data or duplicated cards. The reader should have audio transducer to provide various tone sequences to signify access granted, access denied, power up and diagnostics. Visually impaired cardholders can easily distinguish between access granted and access denied. High-intensity light bar should provide a clear visual status indication in red, green or amber, even in bright sunlight. Nos. 30.000 998521 Confirmed 18 Confirmed 0.00 0.01
6 Supply, testing and commissioning of iClass Smart card. Nos. 500.000 998521 Confirmed 18 Confirmed 0.00 0.01
7 Supply, installation, testing and commissioning of Double Leaf Electro Magnetic Lock of Suitable Capacity(Min 600+600 lbs). Nos. 17.000 998521 Confirmed 18 Confirmed 0.00 0.01
8 Supply and Fixing of ''U'' Bracket with Accessories. Nos. 17.000 998521 Confirmed 18 Confirmed 0.00 0.01
9 Supply, Fixing and Laying of 8 Core 1 Sq mm copper, unarmoured Cable (between the every readers & the access controllers). Mtr 3500.000 998521 Confirmed 18 Confirmed 0.00 0.01
10 Supply, Fixing and Laying of 4 Core 1 Sq mm copper, unarmoured Cable Mtr 1700.000 998521 Confirmed 18 Confirmed 0.00 0.01
11 Supply, testing and commissioning of Panic Bar Nos. 5.000 998521 Confirmed 18 Confirmed 0.00 0.01
12 Supply, testing and commissioning of LSA Nos. 5.000 998521 Confirmed 18 Confirmed 0.00 0.01
13 Supply, Fixing and Laying of 20 MM PVC Conduit Mtr 5000.000 998521 Confirmed 18 Confirmed 0.00 0.01
TOTAL 0.03 0.00 #REF!
# In case the bidder leaves the cell for confirmation of the SAC/HSN code and/or GST rate “blank”, the SAC/HSN code and corresponding GST rate indicated by the Employer shall be deemed to be the one confirmed by the Bidder.
Date : Printed Name :
Place : Designation :
Specification No.: ODP/BB/C&M-3575/OT-24/RFx No. 5002003243/23-24 Schedule - 1H (Video Surveillance System (IP CCTV))
Construction of a Control Centre Building for OPTCL STAMS (State Transmission Asset Management System) Project by POWERGRID under Consultancy Services to OPTCL As per Lum-sum
(SCHEDULE OF RATES AND PRICES ) AS per Percent
As per lum-sum on Sch-3
Bidder’s Name and Address To: As per Percent on Sch-3
#REF! Sr. GM(C&M) Multipackage lum-sum
Name: POWER GRID CORPORATION OF INDIA LIMITED, Multipackage on Percent
Address: ODISHA PROJECTS Total Discount
PLOT NO.-4, UNIT-41, NILADRI VIHAR
CHANDRASHEKHARPUR, BHUBANESWAR-751021
Video Surveillance System (IP CCTV) All Prices are in Indian Rupees.
SI. No. Service Activity Number DSR 2023/NSR Item Description Unit Qty. SAC/HSN Codes Whether SAC/HSN in column ‘4’ is confirmed. If not indicate applicable the SAC/HSN # Rate of GST applicable ( in %) Select from Drop-down menu. Whether rate of GST in column ‘6’ is confirmed. If not indicate applicable rate of GST # Unit Rate (excluding GST) but including labour welfare cess & Freight (if any) GST Amount Amount (Excluding GST) but including labour welfare cess & freight (if any) Unit Erection Charges Total Erection Charges
Video Surveillance System (IP CCTV)
1 Supply, installation, testing and commissioning of DOME CAMERA • Max. 2megapixel (1920 x 1080) resolution • 0.03Lux (Color), 0Lux (B/W, IR LED on) • 2.8mm fixed lens • Max. 30fps@2M all resolutions (H.265/H.264) • H.265, H.264, MJPEG codec supported, Multiple streaming • Motion detection, Tampering, Defocus detection • Hallway view (90°/270°), LDC support • Micro SD/SDHC/SDXC memory slot (Max. 128GB) • IR viewable length 20m • IP66, IK10, PoE, 12VDC Each 40.000 998521 Confirmed 18 Confirmed 0.00 0.01
2 Supply, installation, testing and commissioning of Bullet Camera -ANPR with required pole. • Max. 2megapixel (1920 x 1080) resolution • 0.03lux (Color), 0Lux (B/W, IR LED on) • 3.2 ~ 10mm (3.1x) motorized varifocal lens • Max. 30fps@2M all resolutions (H.265/H.264) • H.265, H.264, MJPEG codec supported, Multiple streaming • Motion detection, Tampering, Defocus detection • Hallway view (90°/270°), LDC support • Micro SD/SDHC/SDXC memory slot (Max. 128GB) • IR viewable length 30m • IP66, IK10, PoE/12VDC Each 2.000 998521 Confirmed 18 Confirmed 0.00 0.01
3 Supply, installation, testing and commissioning of PTZ Camera • Max. 2MP resolution • 4.25~170mm (40x) zoom (digital 32x, total 1280x zoom) • Max. IR viewable length 200m (656.17ft), Wise IR • Day & Night (ICR), extreme WDR, DIS(Built-in gyro sensor) • Intelligent analytics, Object auto tracking (Person/Vehicle), Target lock tracking • H.264, H.265, MJPEG codec, WiseStream II • IP66, IK10, NEMA4X, NEMA-TS 2 (2.2.8, 2.2.9) • PTZ PLUS Design applied (Compact, Lighter, Simple cabling) • SFP-supported by injector Each 4.000 998521 Confirmed 18 Confirmed 0.00 0.01
4 Supply, installation, testing and commissioning of ANPR Video Analytics Each 2.000 998521 Confirmed 18 Confirmed 0.00 0.01
5 Supply, installation, testing and commissioning of ANPR workstation with minimun specs recommended by OEM. Each 1.000 998521 Confirmed 18 Confirmed 0.00 0.01
5.1 Supply, installation, testing and commissioning of 55" Monitor with minimun specs. Each 2.000 998521 Confirmed 18 Confirmed 0.00 0.01
6 Supply, Installation, Testing & Commissioning of Video management software. The VMS application must have native capability to scale into a full fetched Command & Control platform and capability to provide incident management features like Rule engine, SOP ‘s and Incident reports with no dependency on any external 3rd party software. Security Center Base software, with Primary Directory software license & 1 failover directory license. The proposed VMS platform must be UL 2900-2-3 Level 3 Cybersecurity certification Nos 1.000 998521 Confirmed 18 Confirmed 0.00 0.01
7 Supply, installation, testing and commissioning of Camera License for working & failover connection. The Proposed Solution shall support native Fail over with in application with no dependency on any external application for both hardware and application redundancy. The native fail over architecture must be for both management and recording servers. Video Management System should support End to End Multicast (i.e Clients should be able to view the video Footages Directly from the Multicast stream of the Cameras) with 5 years support Nos 46.000 998521 Confirmed 18 Confirmed 0.00 0.01
8 Supply, installation, testing and commissioning of All in one Video recording server with 48TB RAW storage 43 TB Usable Dell OptiPlex T4: Dell Precision 3650 XE 1x 256 GB SSD (1) 1GBE RJ45 (1GbE port standard, option for 2x 1Gbe ports) (Display Connections: 2x DisplayPort). Recording parameters at 25 FPS @1080P for 30 Days Nos 1.000 998521 Confirmed 18 Confirmed 0.00 0.01
9 Supply, installation, testing & commissioning of 24 Port PoE+ Switch with 2 SFP slots Nos 5.000 998521 Confirmed 18 Confirmed 0.00 0.01
10 Supply, installation, testing & commissioning of L2 managed 08-Port POE enabled 10/100/1000BASE-T switch with 2 SFP ports module populated Nos 2.000 998521 Confirmed 18 Confirmed 0.00 0.01
11 Supply, installation, testing & commissioning of 15 U Network Rack Nos 1.000 998521 Confirmed 18 Confirmed 0.00 0.01
12 Supply, installation, testing & commissioning of 6 U Network Rack Nos 5.000 998521 Confirmed 18 Confirmed 0.00 0.01
13 Supply, installation, testing & commissioning of 12 Port LIU Nos 4.000 998521 Confirmed 18 Confirmed 0.00 0.01
14 Supply, installation, testing & commissioning of 24 port cat 6 UTP fully loaded patch panel Nos 6.000 998521 Confirmed 18 Confirmed 0.00 0.01
15 Supply, installation, testing & commissioning of Cat-6 IO Nos 47.000 998521 Confirmed 18 Confirmed 0.00 0.01
16 Supply, installation, testing & commissioning of 6 core OFC outdoor armoured cable Nos 500.000 998521 Confirmed 18 Confirmed 0.00 0.01
17 OFC SM duplex patch chord 2m (SC-LC) Nos 8.000 998521 Confirmed 18 Confirmed 0.00 0.01
18 Supply, installation, testing & commissioning of OFC SM duplex patch chord 2m (SC-LC) Nos 4.000 998521 Confirmed 18 Confirmed 0.00 0.01
19 Supply, installation, testing & commissioning of cat 6 UTP Patch chord -1m Nos 47.000 998521 Confirmed 18 Confirmed 0.00 0.01
20 Supply, installation, testing & commissioning of cat 6 UTP Patch chord -2m Nos 50.000 998521 Confirmed 18 Confirmed 0.00 0.01
21 Supply, installation, testing & commissioning of cat 6 UTP cable Nos 6500.000 998521 Confirmed 18 Confirmed 0.00 0.01
22 Supply, installation, testing & commissioning of 20mm PVC Conduit Nos 6500.000 998521 Confirmed 18 Confirmed 0.00 0.01
23 Supply, installation, testing & commissioning of 3 Meter Pole with required Civil Works Nos 4.000 998521 Confirmed 18 Confirmed 0.00 0.01
24 Excavation & refilling of soft soil Nos 500.000 998521 Confirmed 18 Confirmed 0.00 0.01
25 HDPE Pipe 50 mm Nos 500.000 998521 Confirmed 18 Confirmed 0.00 0.01
TOTAL 0.05 0.00 #REF!
# In case the bidder leaves the cell for confirmation of the SAC/HSN code and/or GST rate “blank”, the SAC/HSN code and corresponding GST rate indicated by the Employer shall be deemed to be the one confirmed by the Bidder.
Date : Printed Name :
Place : Designation :
Specification No.: ODP/BB/C&M-3575/OT-24/RFx No. 5002003243/23-24 Schedule - 1I (EPABX)
Construction of a Control Centre Building for OPTCL STAMS (State Transmission Asset Management System) Project by POWERGRID under Consultancy Services to OPTCL As per Lum-sum
(SCHEDULE OF RATES AND PRICES ) AS per Percent
As per lum-sum on Sch-3
Bidder’s Name and Address To: As per Percent on Sch-3
#REF! Sr. GM(C&M) Multipackage lum-sum
Name: POWER GRID CORPORATION OF INDIA LIMITED, Multipackage on Percent
Address: ODISHA PROJECTS Total Discount
PLOT NO.-4, UNIT-41, NILADRI VIHAR
CHANDRASHEKHARPUR, BHUBANESWAR-751021
EPABX All Prices are in Indian Rupees.
SI. No. Service Activity Number DSR 2023/NSR Item Description Unit Qty. SAC/HSN Codes Whether SAC/HSN in column ‘4’ is confirmed. If not indicate applicable the SAC/HSN # Rate of GST applicable ( in %) Select from Drop-down menu. Whether rate of GST in column ‘6’ is confirmed. If not indicate applicable rate of GST # Unit Rate (excluding GST) but including labour welfare cess & Freight (if any) GST Amount Amount (Excluding GST) but including labour welfare cess & freight (if any) Unit Erection Charges Total Erection Charges
1 Supply and Installation of Pure IP Hardware Plat from for Unified Communication Server, 19" Rack Mount with 1U Enclosure The 50 IP Extensions expandable up to 100 IP Extensions (License software from Day1) Pure IP communication system should be configured for: 1- no’s of Operator console IP based with each operator console 16 Keys Direct Station Selection(DSS) 4 - no’s of PSTN trunk port 1 - no’s of PRI port (ISDN & SIP compatible) 50 - no’s of IP user license 100% non- blocking architecture Nos 1.000 998413 Confirmed 18 Confirmed 0.00 0.01
2 IP phone and Operator console with POE, IP/DSS Console with 32 special keysmust be same as per OEM of IP-PBX. • VoIP Protocol: Proprietary • Ethernet Ports: 2 (PC and LAN) • Display: 240 x 64 Pixels Graphical LCD with Backlit • Color: Black • Programmable Keys: 4 Context Sensitive Keys, 16 DSS Keys • Power Supply: PoE Nos 1.000 998413 Confirmed 18 Confirmed 0.00 0.01
3 Entry-level Gigabit IP PhoneStandard SIP Phone with PoE • Ethernet Ports: 2 (Gigabit ports - PC and LAN) • Display: 128 x 64 Pixels Graphical LCD (3.1 Inch) • Color: Black • Functional Keys:3 Feature Keys, 4 Context Sensitive Keys, 2 Line Keys, Volume Control Keys Nos 47.000 998413 Confirmed 18 Confirmed 0.00 0.01
4 Supply, installation, testing & commissioning of 24 U Network Rack Nos 1.000 998413 Confirmed 18 Confirmed 0.00 0.01
5 Testing and commissiong Nos 1.000 998413 Confirmed 18 Confirmed 0.00 0.01
TOTAL 0.01 0.00 #REF!
# In case the bidder leaves the cell for confirmation of the SAC/HSN code and/or GST rate “blank”, the SAC/HSN code and corresponding GST rate indicated by the Employer shall be deemed to be the one confirmed by the Bidder.
Date : Printed Name :
Place : Designation :
Specification No.: ODP/BB/C&M-3575/OT-24/RFx No. 5002003243/23-24 Schedule - 1J (ELECTRICAL FENCING)
Construction of a Control Centre Building for OPTCL STAMS (State Transmission Asset Management System) Project by POWERGRID under Consultancy Services to OPTCL As per Lum-sum
(SCHEDULE OF RATES AND PRICES ) AS per Percent
As per lum-sum on Sch-3
Bidder’s Name and Address To: As per Percent on Sch-3
#REF! Sr. GM(C&M) Multipackage lum-sum
Name: POWER GRID CORPORATION OF INDIA LIMITED, Multipackage on Percent
Address: ODISHA PROJECTS Total Discount
PLOT NO.-4, UNIT-41, NILADRI VIHAR
CHANDRASHEKHARPUR, BHUBANESWAR-751021
ELECTRICAL FENCING All Prices are in Indian Rupees.
SI. No. Service Activity Number DSR 2023/NSR Item Description Unit Qty. SAC/HSN Codes Whether SAC/HSN in column ‘4’ is confirmed. If not indicate applicable the SAC/HSN # Rate of GST applicable ( in %) Select from Drop-down menu. Whether rate of GST in column ‘6’ is confirmed. If not indicate applicable rate of GST # Unit Rate (excluding GST) but including labour welfare cess & Freight (if any) GST Amount Amount (Excluding GST) but including labour welfare cess & freight (if any) Unit Erection Charges Total Erection Charges
ELECTRICAL FENCING
1 Supply of Gallagher 6000 Network controller with Command Center Software along with necessary cabling, accessories Etc complete in all respects Each 1.000 995477 Confirmed 18 Confirmed 0.00 0.01
2 Supply of F42 fence controller with appropriate outdoor weatherproof enclosures, necessary cabling, accessories Etc complete in all respects Each 1.000 995477 Confirmed 18 Confirmed 0.00 0.01
3 Supply of Fence hardware consisting Hot Dip Galvanized Kiwitah Posts, Hot Dip Galvanized 50NB MS pipe with 32NB pipe for stay support, UV Stabilized insulators, Wire Tightners, Earth System, Warning Sign Boards and Etc accessories Each 1.000 995477 Confirmed 18 Confirmed 0.00 0.01
4 Installation, testing, commissioning, auditing and training to the Security and Maintenance staff Each 1.000 995477 Confirmed 18 Confirmed 0.00 0.01
TOTAL 0.01 0.00 #REF!
# In case the bidder leaves the cell for confirmation of the SAC/HSN code and/or GST rate “blank”, the SAC/HSN code and corresponding GST rate indicated by the Employer shall be deemed to be the one confirmed by the Bidder.
Date : Printed Name :
Place : Designation :
Specification No.: ODP/BB/C&M-3575/OT-24/RFx No. 5002003243/23-24 Schedule - 1K (BUILDING MANAGEMENT SYSTEM)
Construction of a Control Centre Building for OPTCL STAMS (State Transmission Asset Management System) Project by POWERGRID under Consultancy Services to OPTCL As per Lum-sum
(SCHEDULE OF RATES AND PRICES ) AS per Percent
As per lum-sum on Sch-3
Bidder’s Name and Address To: As per Percent on Sch-3
#REF! Sr. GM(C&M) Multipackage lum-sum
Name: POWER GRID CORPORATION OF INDIA LIMITED, Multipackage on Percent
Address: ODISHA PROJECTS Total Discount
PLOT NO.-4, UNIT-41, NILADRI VIHAR
CHANDRASHEKHARPUR, BHUBANESWAR-751021
BUILDING MANAGEMENT SYSTEM All Prices are in Indian Rupees.
SI. No. Service Activity Number DSR 2023/NSR Item Description Unit Qty. SAC/HSN Codes Whether SAC/HSN in column ‘4’ is confirmed. If not indicate applicable the SAC/HSN # Rate of GST applicable ( in %) Select from Drop-down menu. Whether rate of GST in column ‘6’ is confirmed. If not indicate applicable rate of GST # Unit Rate (excluding GST) but including labour welfare cess & Freight (if any) GST Amount Amount (Excluding GST) but including labour welfare cess & freight (if any) Unit Erection Charges Total Erection Charges
BUILDING MANAGEMENT SYSTEM
1 BMS server / PC: Supply, installation, testing & commissioning of BMS Server cum Workstation with Intel Core i7 processor, 16GB RAM, 1TB HDD & required standard accessories as per OEM recommendation including 26" FHD, LED Flat Monitor & HDMI cable. No. 1.000 995461 Confirmed 18 Confirmed 0.00 0.01
1a 16 Port Non POE, L2 Network switch No. 1.000 995461 Confirmed 18 Confirmed 0.00 0.01
2 Supply, installation, testing & commissioning of BMS Software with unlimited Client Licenses includes GUI & MMI software. Software shall have capacity for IO points listed in IO summary and expandable in future as required. Should have 128 bit SSL security, user configuration, unlimited client license. Lot 1.000 995461 Confirmed 18 Confirmed 0.00 0.01
3 Integrator Supply, installation, testing & commissioning of Software Integrators / Protocol Convertors for the following systems capable of integrating any Industrially acceptable open Communication Protocols, simultaneously, including but not limited to : Modbus RTU / Modbus ASCII / BACnet / Lonworks / M Bus; Made Available either on Serial RS 485 Network or TCP / IP Network. Each Integrator should have 2 built in RS485 ports and expandable upto 6 ports in total, 2GB memory for local storage & programming & event management. Integrator local access shall be restricted with user name & password. Each Integrator shall support atleast 150 slave devices as minimum Each integrator should be provided with 15% Spare points. Configuration & number of Integrators to be decided by the vendor as per their devices system capacity, equipments location & IO summary points) Lot 1.000 995461 Confirmed 18 Confirmed 0.00 0.01
a VRF - Outdoor, Indoor & Ductable- 520 Points No. 52.000
b VFD - Ductable units- 230 Points No. 23.000
c UPS- 50 Points No. 2.000
d Breakers-200 Points No. 10.000
e Lift- 10 Points No. 2.000
f Fire alarm Panel- 250 Points No. 1.000
4 Supply, installation, testing & commissioning of 32 Bit freely programmable Direct Digital Controllers (DDCs), Should have on board TCP/IP network connectivity, IO expansion capability with Add-On IO modules, complete with DDC Housing Panels. The ddc Shall support minimum of 16 points & expandable upto 180 points with expansion modules. The DDC Panel shall be MS Powder Coated, IP 54 (indoor) / IP 65 (outdoor) Rating with proper mounting accessories for DDCs such as DIN Rails, Terminals for Cable Terminations, Dressing for all internal cabling , ferruling, tagging etc. The DDC Panels shall have Power Supply to meet the power requirement of the DDCs, Instrumentation and other connected equipment, auxiliary power output socket etc. as required to complete the installation and intended usage. Each DDC should be provided with 15% Spare I/O points.
a DDC Set 1.000 995461 Confirmed 18 Confirmed 0.00 0.01
5 Field Sensors
5.1 Duct type temperature & RH sensor No. 23.000 995461 Confirmed 18 Confirmed 0.00 0.01
5.2 DP Switch for Filter No. 33.000 995461 Confirmed 18 Confirmed 0.00 0.01
5.3 DP Transmitter for Air No. 23.000 995461 Confirmed 18 Confirmed 0.00 0.01
5.4 H2 Sensor No. 1.000 995461 Confirmed 18 Confirmed 0.00 0.01
6 Cables & Cable Trays
6.1 2 x 1.0 sq.mm Copper Shielded armoured cable for signal & RS485 communication. Mtrs 3000.000 995461 Confirmed 18 Confirmed 0.00 0.01
6.2 4 x 1.0 sq.mm Copper Shielded armoured cable for signal. Mtrs 700.000 995461 Confirmed 18 Confirmed 0.00 0.01
6.3 3C x 1.5 sq.mm Armoured Unshielded Copper cable for power. Mtrs 250.000 995461 Confirmed 18 Confirmed 0.00 0.01
6.4 Cat 6 communication Un-armoured cable Mtrs 300.000 995461 Confirmed 18 Confirmed 0.00 0.01
6.5 20mm PVC Conduit Mtrs 300.000 995461 Confirmed 18 Confirmed 0.00 0.01
TOTAL 0.03 0.00 #REF!
# In case the bidder leaves the cell for confirmation of the SAC/HSN code and/or GST rate “blank”, the SAC/HSN code and corresponding GST rate indicated by the Employer shall be deemed to be the one confirmed by the Bidder.
Date : Printed Name :
Place : Designation :
Specification No.: ODP/BB/C&M-3575/OT-24/RFx No. 5002003243/23-24 Schedule - 1L (PARKING MANAGEMENT SYSTEM)
Construction of a Control Centre Building for OPTCL STAMS (State Transmission Asset Management System) Project by POWERGRID under Consultancy Services to OPTCL As per Lum-sum
(SCHEDULE OF RATES AND PRICES ) AS per Percent
As per lum-sum on Sch-3
Bidder’s Name and Address To: As per Percent on Sch-3
#REF! Sr. GM(C&M) Multipackage lum-sum
Name: POWER GRID CORPORATION OF INDIA LIMITED, Multipackage on Percent
Address: ODISHA PROJECTS Total Discount
PLOT NO.-4, UNIT-41, NILADRI VIHAR
CHANDRASHEKHARPUR, BHUBANESWAR-751021
PARKING MANAGEMENT SYSTEM All Prices are in Indian Rupees.
SI. No. Service Activity Number DSR 2023/NSR Item Description Unit Qty. SAC/HSN Codes Whether SAC/HSN in column ‘4’ is confirmed. If not indicate applicable the SAC/HSN # Rate of GST applicable ( in %) Select from Drop-down menu. Whether rate of GST in column ‘6’ is confirmed. If not indicate applicable rate of GST # Unit Rate (excluding GST) but including labour welfare cess & Freight (if any) GST Amount Amount (Excluding GST) but including labour welfare cess & freight (if any) Unit Erection Charges Total Erection Charges
PARKING MANAGEMENT SYSTEM
1 Supply, testing and commissioning of parking management software (Annual Recurring)- Cloud Portal Nos. 50.000 996743 Confirmed 18 Confirmed 0.00 0.01
2 Supply, testing and commissioning of Mobile app charges (per user per year) Nos. 50.000 996743 Confirmed 18 Confirmed 0.00 0.01
3 Supply, testing and commissioning of 3rd party integration charges (one time) Nos. 1.000 996743 Confirmed 18 Confirmed 0.00 0.01
4 Supply, testing and commissioning of Slot Sensor Nos. 50.000 996743 Confirmed 18 Confirmed 0.00 0.01
5 Supply, testing and commissioning of Display Nos. 1.000 996743 Confirmed 18 Confirmed 0.00 0.01
6 Supply, testing and commissioning of Access controller for gate Nos. 1.000 996743 Confirmed 18 Confirmed 0.00 0.01
7 Supply, testing and commissioning of 3mtr Boom Barrier Nos. 4.000 996743 Confirmed 18 Confirmed 0.00 0.01
8 Supply, testing and commissioning of Push Button Nos. 4.000 996743 Confirmed 18 Confirmed 0.00 0.01
9 i7 Machine with Latest Processor, 8GB RAM 1GB Graphics Card Built in DVD R/W drive 1 TB HDD Keyboard, Mouse, Windows/Linux Latest OS 24'' inch display Nos. 1.000 996743 Confirmed 18 Confirmed 0.00 0.01
10 Supply, Fixing and Laying of 3 Core 1.5 Sq shielded mm copper, armoured Cable Mtr 500.000 996743 Confirmed 18 Confirmed 0.00 0.01
11 Supply, Fixing and Laying of 2 Core 1.5 Sq shielded mm copper, armoured Cable Mtr 2500.000 996743 Confirmed 18 Confirmed 0.00 0.01
TOTAL 0.02 0.00 #REF!
# In case the bidder leaves the cell for confirmation of the SAC/HSN code and/or GST rate “blank”, the SAC/HSN code and corresponding GST rate indicated by the Employer shall be deemed to be the one confirmed by the Bidder.
Date : Printed Name :
Place : Designation :
Specification No.: ODP/BB/C&M-3575/OT-24/RFx No. 5002003243/23-24 Schedule - 1M (Video Conference System)
Construction of a Control Centre Building for OPTCL STAMS (State Transmission Asset Management System) Project by POWERGRID under Consultancy Services to OPTCL As per Lum-sum
(SCHEDULE OF RATES AND PRICES ) AS per Percent
As per lum-sum on Sch-3
Bidder’s Name and Address To: As per Percent on Sch-3
#REF! Sr. GM(C&M) Multipackage lum-sum
Name: POWER GRID CORPORATION OF INDIA LIMITED, Multipackage on Percent
Address: ODISHA PROJECTS Total Discount
PLOT NO.-4, UNIT-41, NILADRI VIHAR
CHANDRASHEKHARPUR, BHUBANESWAR-751021
Video Conference System All Prices are in Indian Rupees.
SI. No. Service Activity Number DSR 2023/NSR Item Description Unit Qty. SAC/HSN Codes Whether SAC/HSN in column ‘4’ is confirmed. If not indicate applicable the SAC/HSN # Rate of GST applicable ( in %) Select from Drop-down menu. Whether rate of GST in column ‘6’ is confirmed. If not indicate applicable rate of GST # Unit Rate (excluding GST) but including labour welfare cess & Freight (if any) GST Amount Amount (Excluding GST) but including labour welfare cess & freight (if any) Unit Erection Charges Total Erection Charges
Video Conference System
1 Video Conference : Video Conferencing Equipment for 7 party (1080P) conferencing with 12x Camera Nos 1.000 998424 Confirmed 18 Confirmed 0.00 0.01
2 65" Standard LED display for video conference system with wall mounting bracket Nos 2.000 998424 Confirmed 18 Confirmed 0.00 0.01
3 Supply, Installation, testing and commissioning of 240 W Mixer amplifier Nos 1.000 998424 Confirmed 18 Confirmed 0.00 0.01
4 Supply, Installation, testing and commissioning of 6 W wall mounted speaker 100 V line for indoor application Nos 4.000 998424 Confirmed 18 Confirmed 0.00 0.01
5 Supply, Installation, testing and commissioning of Digital Discussion System and have miniumum 80 discussion and expandable upto 245 devices, the control unit shall have MP3 recording and Digital Acoustic Feedback Suppression . Nos 1.000 998424 Confirmed 18 Confirmed 0.00 0.01
6 Supply, Installation, testing and commissioning of Digital Discussion System Extension unit and shall be expandable upto 245 devices, Single Extension Unit can provide power for up to 85 additional Discussion and One trunk and two tap‑off connections with short‑circuit protection Nos 1.000 998424 Confirmed 18 Confirmed 0.00 0.01
7 Supply, Installation, testing and commissioning of Discussion device with long Microphone with Plug and play functionality for ensuring fast installation and reconfiguration times, the microphone shall have the following features, Request‑to‑speak indication, Microphone with flexible stem, Built-in loudspeaker with volume control, Face-to-face meeting feeling and Headphones socket Nos 33.000 998424 Confirmed 18 Confirmed 0.00 0.01
8 Supply, Installation, testing and commissioning of Extension Cables with Low smoke zero halogen to comply with safety and environmental standards. Nos 1.000 998424 Confirmed 18 Confirmed 0.00 0.01
9 Supply and Fixing of 24U rack for install all AV equipment etc. complete. Nos 1.000 998424 Confirmed 18 Confirmed 0.00 0.01
10 Supply and laying of HDMI & VGA Wall plate. Nos 2.000 998424 Confirmed 18 Confirmed 0.00 0.01
11 Supply and laying of 10Mtr HDMI Cable. Nos 2.000 998424 Confirmed 18 Confirmed 0.00 0.01
12 Supply and laying of 5Mtr HDMI Patch Cable. Nos 2.000 998424 Confirmed 18 Confirmed 0.00 0.01
13 Supply and laying of 5Mtr VGA Patch Cable. Nos 2.000 998424 Confirmed 18 Confirmed 0.00 0.01
14 Supply and laying of 2 core * 0.75 sq mm speaker cable Mts 500.000 998424 Confirmed 18 Confirmed 0.00 0.01
15 Supply, Fixing and Laying of 20 MM PVC Conduit Mts 500.000 998424 Confirmed 18 Confirmed 0.00 0.01
TOTAL 0.03 0.00 #REF!
# In case the bidder leaves the cell for confirmation of the SAC/HSN code and/or GST rate “blank”, the SAC/HSN code and corresponding GST rate indicated by the Employer shall be deemed to be the one confirmed by the Bidder.
Date : Printed Name :
Place : Designation :
Specification No.: ODP/BB/C&M-3575/OT-24/RFx No. 5002003243/23-24 Schedule - 1N (ADDITIONAL SECURITY SYSTEM )
Construction of a Control Centre Building for OPTCL STAMS (State Transmission Asset Management System) Project by POWERGRID under Consultancy Services to OPTCL As per Lum-sum
(SCHEDULE OF RATES AND PRICES ) AS per Percent
As per lum-sum on Sch-3
Bidder’s Name and Address To: As per Percent on Sch-3
#REF! Sr. GM(C&M) Multipackage lum-sum
Name: POWER GRID CORPORATION OF INDIA LIMITED, Multipackage on Percent
Address: ODISHA PROJECTS Total Discount
PLOT NO.-4, UNIT-41, NILADRI VIHAR
CHANDRASHEKHARPUR, BHUBANESWAR-751021
ADDITIONAL SECURITY SYSTEM All Prices are in Indian Rupees.
SI. No. Service Activity Number DSR 2023/NSR Item Description Unit Qty. SAC/HSN Codes Whether SAC/HSN in column ‘4’ is confirmed. If not indicate applicable the SAC/HSN # Rate of GST applicable ( in %) Select from Drop-down menu. Whether rate of GST in column ‘6’ is confirmed. If not indicate applicable rate of GST # Unit Rate (excluding GST) but including labour welfare cess & Freight (if any) GST Amount Amount (Excluding GST) but including labour welfare cess & freight (if any) Unit Erection Charges Total Erection Charges
ADDITIONAL SECURITY SYSTEM
1 Supply, Installation, Testing & Commissioning of 8 Zone Door Frame Metal Detector with all required accessories. Nos. 4.000 998736 Confirmed 18 Confirmed 0.00 0.01
2 Supply, Installation, Testing & Commissioning of Handheld Metal Detector. Nos. 4.000 998736 Confirmed 18 Confirmed 0.00 0.01
3 Supply, Installation, Testing & Commissioning of X-Ray Baggage Scanner with all required monitoring station, Hardware & Accessories.
i Tunnel Size- 500 MM X 300 MM ( FOR MAIL & HANDBAG ) Nos. 2.000 998736 Confirmed 18 Confirmed 0.00 0.01
ii Tunnel Size- 650 MM X 350 MM (FOR BAGGAGE) Nos. 2.000 998736 Confirmed 18 Confirmed 0.00 0.01
4 Supply, Installation, Testing & Commissioning of Female Frisking with all required accessories. Nos. 2.000 998736 Confirmed 18 Confirmed 0.00 0.01
TOTAL 0.01 0.00 #REF!
# In case the bidder leaves the cell for confirmation of the SAC/HSN code and/or GST rate “blank”, the SAC/HSN code and corresponding GST rate indicated by the Employer shall be deemed to be the one confirmed by the Bidder.
Date : Printed Name :
Place : Designation :
Specification No.: ODP/BB/C&M-3575/OT-24/RFx No. 5002003243/23-24 Schedule - 1O (HVAC WORKS)
Construction of a Control Centre Building for OPTCL STAMS (State Transmission Asset Management System) Project by POWERGRID under Consultancy Services to OPTCL As per Lum-sum
(SCHEDULE OF RATES AND PRICES ) AS per Percent
As per lum-sum on Sch-3
Bidder’s Name and Address To: As per Percent on Sch-3
#REF! Sr. GM(C&M) Multipackage lum-sum
Name: POWER GRID CORPORATION OF INDIA LIMITED, Multipackage on Percent
Address: ODISHA PROJECTS Total Discount
PLOT NO.-4, UNIT-41, NILADRI VIHAR
CHANDRASHEKHARPUR, BHUBANESWAR-751021
HVAC WORKS All Prices are in Indian Rupees.
SI. No. Service Activity Number DSR 2019/NSR Item Description Unit Qty. SAC/HSN Codes Whether SAC/HSN in column ‘4’ is confirmed. If not indicate applicable the SAC/HSN # Rate of GST applicable ( in %) Select from Drop-down menu. Whether rate of GST in column ‘6’ is confirmed. If not indicate applicable rate of GST # Unit Rate (excluding GST) but including labour welfare cess & Freight (if any) GST Amount Amount (Excluding GST) but including labour welfare cess & freight (if any) Unit Erection Charges Total Erection Charges
VRF/VRV OUTDOOR UNITS
1 1 Supply Installation,Testing&CommissioningofmodulartypeVariableRefrigerantFlow/VariableRefrigerantVolumeaircooledOutdoorunitssuitableforcoolingandheating,havingallhermeticallysealedinvertertypeScrollCompressor(s),minimumtwocompressorsforabove14HPmodules, microprocessorbasedController,topdischarge typecondensingunit(s),withR410ARefrigerant,vibrationisolators,withsuitablefoundationetc.completeasrequired.TheunitshalldelivertheratedcapacityatAHRIConditionsandworkevenat 50°C ambienttemperaturewithouttripping.Theunitshallbesuitabletoworkon400V+/-10%,3Phase,50HzACpowersupply.Theunit shallbefilledwithfirstchargeoftherefrigerantandreadyforuseasrequired.TheCOPatAHRI conditions shall not be less than 3.1 and IEER not less than 6.5 .
1.1 10 HP Nos 1.000 995463 Confirmed 18 Confirmed 0.00 0.01
1.2 40 HP Nos 1.000 995463 Confirmed 18 Confirmed 0.00 0.01
1.3 38 HP Nos 1.000 995463 Confirmed 18 Confirmed 0.00 0.01
1.4 54 HP Nos 1.000 995463 Confirmed 18 Confirmed 0.00 0.01
1.5 66 HP (40+16 HP) Nos 1.000 995463 Confirmed 18 Confirmed 0.00 0.01
INDOOR UNITS CASSETTE TYPE
2 2 Supply,installation,testingandcommissioningoffollowingminimumcapacity4-wayflowVRV/VRFCassetteTypeIndoorceilingmountedunitequippedwithsyntheticwashablemediapre-filter,fansectionwithlownoisefan/dynamicallybalancedblower,multispeedmotor,coilsectionwithDXCoppercoil,electronicexpansionvalve,outercabinet,drainpump,grill,necessarysupports,vibrationisolation,cordlessremotecontroletc.,suitableforoperationonsinglephase230V±10%,50HzACsupply,complete,asrequired.TheunitshallhaveautomaticforceshutdownprovisionincaseoffireonreceivingsignalfromBMSSystem.Thecoolingcapacityofindoorunitwillbeatairinletconditionsof27DegreeCDBand19DegreeCWB temperature.
2.1 2.2 1.0 TR Nos 7.000 995463 Confirmed 18 Confirmed 0.00 0.01
2.2 2.4 1.6 TR Nos 7.000 995463 Confirmed 18 Confirmed 0.00 0.01
2.3 2.5 2.0 TR Nos 6.000 995463 Confirmed 18 Confirmed 0.00 0.01
2.4 2.56 TR Nos 4.000 995463 Confirmed 18 Confirmed 0.00 0.01
2.5 2.8 3.2 TR Nos 1.000 995463 Confirmed 18 Confirmed 0.00 0.01
INDOOR UNITS DUCTABLE TYPE
High Static Ductable units (minimum 110 pascal external static pressure)
2.6 5.0 TR Nos 4.000 995463 Confirmed 18 Confirmed 0.00 0.01
2.7 6.4 TR Nos 10.000 995463 Confirmed 18 Confirmed 0.00 0.01
2.8 4.19 8.0 TR Nos 7.000 995463 Confirmed 18 Confirmed 0.00 0.01
3 SERVER ROOM PRECISION AIR CONDITIONER (PAC UNITS)
Supply, Installation, testing and commissioning of Floor Mounted, TOP discharge DX Type PAC units for high density application, equiped with most advanced industry technology to operate at higher return air temperatures , guaranteeing precise control of temperature and relative humidity in UPS and server rooms. #Note: 1) Supplier shall submit computerised unit selection output. Installation also include Lifting, shifting, assemblling & positioning of the equipment comprising of the following and complete as per specification/drawings.
The units shall be selected on the basis of following parameters & must be with extended fan - 26 °C (78.8°F)/35% RH of return air - Minimum COP at Sentible Capacity shall not be less than 2.5 - Each unit shall be provided with - DX coil along with out door unit & its MS stand unit with Refrigerant 410a - For air cooled ambient is 43.2 °C (109.7°F). The intended design shall be to achieve the highest reliability of the system at lowest possible PUE
The unit shall comprise of 20-100% stepless capacity modulating circuits with Digital/Inverter/Combination of Fixed and variable Scroll Compressors, Fibreglass corrossion resistant EC fans, Evaporator cooling Coils , Microprocessor controllers, G4 Filter, Internal power and Control wiring,Humidifier, Heaters, Power and Control contactors, water leak detectors and other Electrical accessories.
The control algorithm shall be for traditional return air logic and also be developed for containment applications, that meets the cooling and airflow needs of the servers while ensuring only necessary kilowatts are invested in targeted cooling. The unit should have the capability to modulate airflow, taking inputs from the remote sensors placed in cold aisle at top of the racks at multiple locations, according to the airflow taken by the servers. The control shall be done in order to have minimum differential pressure between inlet and outlet of the containment. The capacity shall be modulated according to the supply temperature in order to optimize server inlet temperature. The system done by multiple units shall work with efficient cascade way, trying to maximise energy efficiency always working where EC Fans are more effective.
The unit shall be suitable for operation on 415 Volts, 50 Hz, 3 Phase, 4 Wire AC supply. Each unit should be having individual display panel, which shall display date, time, actual & set values, operating conditions, signal faults, collective faults, limiting values and PAC wellness alarm / service alarm to reduce the down time and unit memory shall hold the 400 most recent events with ID number, time and date stamp for each event.
Operation & Control Features - P / PI / PID - All three Control logics for temperature control - Relative / Compensated / Predicttive method for humidity control - Temperature & Humidity graphs for the system (Avg. value of all the connected units) & for each single unit - Record of Peak & Low temperature/humidity of the current day - Choice of display: Graphical / Simple / Graphical Comm diaa / Simple Comm diaa - Display shows SET / ACTUAL / SET+ACTUAL Values - Records total run hours for all main components - Team Mode operation for synchronising upto 16 units in room by any of the unit controller
- Sequencing & Stand-by rotation - Cascading, Lead-Lag functions - 16 days record of controlled parameters - Unit memory shall hold 100 recent alarms with date and time for each alarm - Unit memory shall hold 100 recent alarms with date and time for each alarm - Status report of last 400 event logs - 3 types of access; User, Service & Advanced to protect all settings - Auto restart after a power failure - Graphical display of status of operation of all major components like Fan, Heater & Humidifier on screen in an idle mode - Contains key contact info for local service including names and phone numbers - 254 types of Alarms / Warnings. - Monitoring card should be able to support any one of the protocol (Bacnet/Modbus/SNMP) - Each unit Controller should be capable of controller, monitoring, sharing set points and alarms upto 32 units. - Each Unit controller should have feature of avoiding fighting of operation modes for multiple units thus saving upto 15% power at larger sites - Onboard unit diary provides maintenance history
3.1 3200 CFM, 8 TR (1W+1S) Nos 2.000 995463 Confirmed 18 Confirmed 0.00 0.01
COPPER REFRIGERANT PIPE
4 5 Supply,Installation,testingandcommissioningincludingvaccumiazationandNitrogentestingoffollowingnominalsizesofsoft/harddrawncopperrefrigerantpipingforVRV/VRFsystem,completewithfittings,withsuitableadjustableringtypehangersupports,jointing/brazingincludingaccessories,insulatedwithXPLEClass-Otubularinsulation/withClass-OclosedcellelastometricnitrilerubbertubularsleevessectionsofspecifiedthicknessasgivenbelowforSuctionandLiquidlines,allaccessoriesasperspecifications etc. as required :
4.1 5.1 6.4mmdia(OD)(Softdrawn)withtubethickness1.2mmwith19mmthick insulation RMT 115.000 995463 Confirmed 18 Confirmed 0.00 0.01
4.2 5.2 9.5mmdia(OD)(Softdrawn)withtubethickness1.2mmwith19mmthick insulation RMT 174.000 995463 Confirmed 18 Confirmed 0.00 0.01
4.3 5.3 12.7mmdia(OD)(Softdrawn)withtubethickness1.2mmwith19mm thick insulation RMT 205.000 995463 Confirmed 18 Confirmed 0.00 0.01
4.4 5.4 15.86mmdia(OD)(Softdrawn)withtubethickness1.2mmwith19mm thick insulation RMT 65.000 995463 Confirmed 18 Confirmed 0.00 0.01
4.5 5.5 19mmdia(OD)(Harddrawn)withtubethickness1.2mmwith19mmthick insulation RMT 258.000 995463 Confirmed 18 Confirmed 0.00 0.01
4.6 5.6 22.2mmdia(OD)(Harddrawn)withtubethickness1.2mmwith19mm thick insulation RMT 95.000 995463 Confirmed 18 Confirmed 0.00 0.01
4.7 5.8 28.58mmdia(OD)(Harddrawn)withtubethickness1.2mmwith19mm thick insulation RMT 64.000 995463 Confirmed 18 Confirmed 0.00 0.01
4.8 5.1 34.9mmdia(OD)(Harddrawn)withtubethickness1.62mmwith19mm thick insulation RMT 92.000 995463 Confirmed 18 Confirmed 0.00 0.01
4.9 5.12 41.27mmdia(OD)(Harddrawn)withtubethickness1.62mmwith19mm thick insulation RMT 92.000 995463 Confirmed 18 Confirmed 0.00 0.01
NOTE:-1)TheCopperPiping&PipingCircuitshouldbewithMinimumNumberofjoints,whichshall be attained by : (i) Using One End Expanded Tubes (ii) Bending the tubes instead of using elbow joints wherever 90 degree bending is required. (2)Pipingshouldberoutedatsiteinsuchamanner,thatbrazedjointsintherefrigerationpipingare kept to a minimum. (3) The makes of tube fittings shall be same as that of tubes. (4) The thickness of fittings used shall be same as that of the pipe.
5 Supply and Installation of Refnut Joints Nos 42.000 995463 Confirmed 18 Confirmed 0.00 0.01
6 Supply, Installation, Testing and Commissioning of Central Remote controler campatible to BMS Nos 1.000 995463 Confirmed 18 Confirmed 0.00 0.01
DUCTING, GRILLS,DIFFUSER AND INSULATION
7 16.12.1 (EnM2013) Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.
7.1 16.12.1.1 Thickness 0.63 mm sheet Sqm 1350.000 995463 Confirmed 18 Confirmed 0.00 0.01
7.2 16.12.1.2 Thickness 0.80 mm sheet Sqm 430.000 995463 Confirmed 18 Confirmed 0.00 0.01
8 16.13 Supply, installation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications. Sqm 6.000 995463 Confirmed 18 Confirmed 0.00 0.01
9 16.17 Supplying, fixing testing commissioning of supply air diffusers of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core. Sqm 42.000 995463 Confirmed 18 Confirmed 0.00 0.01
10 Supply and Installation of Aluminium powder coated drum type JET diffusser with volume control damper and fixing arrangements etc..350 mm DIA Nos 92.000 995463 Confirmed 18 Confirmed 0.00 0.01
11 16.15 Supplying & fixing of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications Sqm 6.000 995463 Confirmed 18 Confirmed 0.00 0.01
12 Supply and installation of Aluminium powder coated Fresh air and Exhaust louver with Bird screen and fixing arrangements etc.. Sqm 6.000 995463 Confirmed 18 Confirmed 0.00 0.01
13 Supply and installation of Aluminium powder coated Non vision door transfer grill with fixing arrangements etc.. Sqm 2.000 995463 Confirmed 18 Confirmed 0.00 0.01
14 16.23 Supplying and fixing of following thickness duly laminated aluminum foil of mat finish closed cell Nitrile rubber (class “O”) insulation on existing duct after applying two coats of cold setting adhesive (CPRX compound). The joints shall sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required.
a 16.23.1 19 mm Sqm 1100.000 995463 Confirmed 18 Confirmed 0.00 0.01
VENTILATION FANS
15 Supply, Intallation, Testing and Commiioning of Cabinet type Single skin ventilation unit with DIDW forward curved fan, three / Single phase motor and drive package for fan & canvass at unit outlet. The outlet Velocity of fan should be within 9.5 m/s. The noise level at a distance of 1.5 m from the fans to be within 65 dba. Supply air fan with Pre filter The motor hall be IE 3 and bove with suitable starter panel also to be included. ( Supply air fan with pre-filter and Exhaust fan will be without filter )
15.1 2200 CFM with 40 mm static Nos 2.000 995463 Confirmed 18 Confirmed 0.00 0.01
15.2 1100 CFM with 30 mm static Nos 7.000 995463 Confirmed 18 Confirmed 0.00 0.01
15.3 2350 CFM with 40 mm static Nos 2.000 995463 Confirmed 18 Confirmed 0.00 0.01
15.4 2000 CFM with 30 mm static Nos 2.000 995463 Confirmed 18 Confirmed 0.00 0.01
15.5 4000 CFM with 50 mm static Nos 2.000 995463 Confirmed 18 Confirmed 0.00 0.01
16 Supply, Intallation, Testing and Commiioning of Cabinet type Double skin ventilation unit with 25 mm panels complete with pre filter filter, DIDW forward curved fan, three phase motor and drive package for fan & canvass at unit outlet. The outlet Velocity of fan should be within 9.5 m/s. The noise level at a distance of 1.5 m from the fans to be within 65 dba. Canopy has to be provided for all outdoor Ventilation units. the motor shall be IE 3 and above with Necessary cabling, end terminations & earthing and VFD starter panel also to be included. The fan motors shall be selected suitable for a VFD drive.
16.1 6000 CFM with 50 mm static Nos 2.000 995463 Confirmed 18 Confirmed 0.00 0.01
17 Supply, Installation. Testing and commissioning of (toilet exhaust)Circular inline exhaust fan, along with motor,Blower and fixing arrangements etc…
17.1 450 CFM Nos 2.000 995463 Confirmed 18 Confirmed 0.00 0.01
18 Supply, Installation. Testing and commissioning of (toilet exhaust) Propellor exhaust fan, along with motor,Blower and fixing arrangements etc…
18.1 150 CFM Nos 3.000 995463 Confirmed 18 Confirmed 0.00 0.01
19 Supply. Intallation, Testing and Commisioning of Insulated Condensate PVC Drain piping with 19 mm thick nitrile rubber insulation etc
19.1 25 mm dia Rmt 75.000 995463 Confirmed 18 Confirmed 0.00 0.01
19.2 32 mm dia Rmt 95.000 995463 Confirmed 18 Confirmed 0.00 0.01
19.3 50 mm dia Rmt 180.000 995463 Confirmed 18 Confirmed 0.00 0.01
20 Supply and laying of Power cable from starter to Ventilation fans comlete with termination etc..
20.1 4C x 4 Sq.mm XLPE/PVC insulated Copper armoured cable Rmt 125.000 995463 Confirmed 18 Confirmed 0.00 0.01
20.2 4C x 1.5 Sq.mm XLPE/PVC insulated Copper armoured cable Rmt 80.000 995463 Confirmed 18 Confirmed 0.00 0.01
21 Supply and laying of Power cable from starter toVRF/VRV ODU complete with termination etc..
21.1 4C x 16 Sq.mm XLPE insulated Copper armoured cable Rmt 60.000 995463 Confirmed 18 Confirmed 0.00 0.01
22 Supply and Installation of GI Cale tray complete with fixing arrangements etc…
22.1 150 mm width X 50 mm depth X 1.6 mm thickness Rmt 360.000 995463 Confirmed 18 Confirmed 0.00 0.01
23 Supply and laying of control cable for the above said VRV / VRFunit capacities between IDU to ODU with conduits and necessary fittings & accessories.(3 core / 2.5 sqmm/suitable cable) RMT 580.000 995463 Confirmed 18 Confirmed 0.00 0.01
24 Supply and Additional Charging of R 410A Refrigerant gas Kgs 85.000 995463 Confirmed 18 Confirmed 0.00 0.01
TOTAL 0.09 0.00 #REF!
# In case the bidder leaves the cell for confirmation of the SAC/HSN code and/or GST rate “blank”, the SAC/HSN code and corresponding GST rate indicated by the Employer shall be deemed to be the one confirmed by the Bidder.
Date : Printed Name :
Place : Designation :
Specification No.: ODP/BB/C&M-3575/OT-24/RFx No. 5002003243/23-24 Schedule - 2
Construction of a Control Centre Building for OPTCL STAMS (State Transmission Asset Management System) Project by POWERGRID under Consultancy Services to OPTCL
SUMMARY OF TAXES & DUTIES APPLICABLE ON GOODS
Bidder’s Name and Address To:
#REF! Sr.GM(C&M)
Name : POWER GRID CORPORATION OF INDIA LIMITED,
Address : ODISHA PROJECTS
PLOT NO.-4, UNIT-41, NILADRI VIHAR
CHANDRASHEKHARPUR, BHUBANESWAR-751021
Sl. No. Item Nos. Total Price (INR) After Discount
1 TOTAL GST ON GOODS 42.02 Excise Duty #REF!
Total GST for Supply of Goods (inter-alia including Type Test Charges) between the Contractor and the Employer (identified in Schedule 1') which are not included in the Ex-works price as per the provision of the Bidding Documents, as applicable. #REF! 340.00
1 TOTAL GST ON SERVICES 6.18 Sales Tax 0.00
Total GST for Services between the Contractor and the Employer (identified in Schedule 1) which are not included in the unit rate as per the provision of the Bidding Documents, as applicable. 1.28 1.1236
GRAND TOTAL 1.28
Place : Printed Name :
Specification No.: ODP/BB/C&M-3575/OT-24/RFx No. 5002003243/23-24 Schedule - 4
Construction of a Control Centre Building for OPTCL STAMS (State Transmission Asset Management System) Project by POWERGRID under Consultancy Services to OPTCL
SUMMARY OF TAXES & DUTIES APPLICABLE ON GOODS
#REF! Contract Services
Name : #REF! Power Grid Corporation of India Ltd.,
Address : #REF! "Saudamini", Plot No.-2
#REF! Sector-29, (near IFFCO Chowk)
#REF! Gurgaon (Haryana) - 122001
Sl. No. Item Nos. Total Price (INR) After Discount
1 TOTAL EXCISE DUTY #REF! Excise Duty #REF!
Total Excise Duty for direct transaction between the Contractor and the Employer (identified in Schedule 1 as 'Direct') which are not included in the Ex-works price as per the provision of the Bidding Documents, as applicable.
Rate of Excise Duty for Direct items indicated in Sch-1 #REF!
2 TOTAL SALES TAX #REF! Sales Tax #REF!
Total Sales Tax for direct transaction between the Contractor and the Employer (identified in Schedule 1 as 'Direct') which are not included in the Ex-works price as per the provision of the Bidding Documents, as applicable.
Quantity on which Sales Tax is applicable #REF!
Rate of Sales Tax #REF!
3 TOTAL VAT #REF! Vat #REF!
Total VAT for direct transaction between the Contractor and the Employer (identified in Schedule 1 as 'Direct') which are not included in the Ex-works price as per the provision of the Bidding Documents, as applicable
Amount on which VAT becomes applicable #REF!
Excise Duty on this Amount #REF!
Rate of VAT #REF!
4 TOTAL OCTROI #REF!
Total Octroi/Entry Tax as applicable for destination site/state on all items of supply, as per the provisions of the Bidding Documents, on all items of Schedule 1. to be paid extra at actual
Click here for details of Octroi
5 TOTAL ENTRY TAX #REF!
Total Octroi/Entry Tax as applicable for destination site/state on all items of supply, as per the provisions of the Bidding Documents, on all items of Schedule 1. to be paid extra at actual
Click here for details of Entry Taxes
6 TOTAL OTHER TAXES & DUTIES #REF!
Total Others levies payable in India (please specify) as applicable for destination site/state on all items of supply, as per the provisions of the Bidding Documents, on all items of Schedule 1. to be paid extra at actual
Click here for details of Entry Taxes
GRAND TOTAL [1+2+3+4+5+6] #REF!
Note : The reimbursement of Excise Duty, Sales Tax/VAT and other levies as per Sl. No. 1 & 2 above subject to provision of ITB Clause 11.4 shall be only against those items for which the Mode of Transaction indicated in Schedule - 1 is 'Direct'. In case of those items in the said Sechedule-1 against which the mode of transaction has been left blank, the same shall be deemed to be 'Bought-out' for the purpose of Evaluation and award of Contract and the price indicated in Schedule 1 against such items shall be deemed to be inclusive of all such taxes, duties and levies.
Date : #REF! Signature :
Place : #REF! Printed Name : #REF!
Designation : #REF!
Specification No.: ODP/BB/C&M-3575/OT-24/RFx No. 5002003243/23-24 Schedule - 3
Construction of a Control Centre Building for OPTCL STAMS (State Transmission Asset Management System) Project by POWERGRID under Consultancy Services to OPTCL
(GRAND SUMMARY)
Bidder’s Name and Address To:
#REF! Sr.GM(C&M)
Name : POWER GRID CORPORATION OF INDIA LIMITED,
Address : ODISHA PROJECTS
PLOT NO.-4, UNIT-41, NILADRI VIHAR
CHANDRASHEKHARPUR, BHUBANESWAR-751021
Sl. No. Description Total Price (INR)
1 TOTAL SCHEDULE NO. 1 #REF!
Ex-works price of Plant and Equipment including Type Test Charges
2 TOTAL SCHEDULE NO. 2 #REF!
Local Transportation, In-transit Insurance, loading and unloading
1 TOTAL SCHEDULE NO. 1
Total price (excluding GST) 0.00
2 TOTAL SCHEDULE NO. 2
Goods and Services Tax on Schedule-1 1.28
5 TOTAL SCHEDULE NO. 6 Not Applicable
Type Test Charges [Total of this Schedule is included in Schedule - 1 above.]
GRAND TOTAL [1+2] 1.28 1.011042
Place : Printed Name :
Specification No.: ODP/BB/C&M-3575/OT-24/RFx No. 5002003243/23-24 Schedule - 5 After Discount
Construction of a Control Centre Building for OPTCL STAMS (State Transmission Asset Management System) Project by POWERGRID under Consultancy Services to OPTCL
(GRAND SUMMARY)
#REF! DY.GENERAL MANAGER(C&M)
Name : #REF! POWER GRID CORPORATION OF INDIA LIMITED,
Address : #REF! ODISHA PROJECTS
#REF! PLOT NO.-4, UNIT-41, NILADRI VIHAR
#REF! CHANDRASHEKHARPUR, BHUBANESWAR-751021
Sl. No. Description Total Price (INR)
1 TOTAL SCHEDULE NO. 1
Ex-works price of Plant and Equipment including Type Test Charges #REF!
2 TOTAL SCHEDULE NO. 2
Local Transportation, Insurance and other Incidental Services #REF!
3 TOTAL SCHEDULE NO. 3
Installation Charges #REF!
4 TOTAL SCHEDULE NO. 4
Taxes and Duties #REF!
5 TOTAL SCHEDULE NO. 6
Type Test Charges [Total of this Schedule is included in Schedule - 1 above.] Not Applicable
GRAND TOTAL [1+2+3+4] #REF!
Place : #REF! Printed Name : #REF!
Designation : #REF!
Specification No.: ODP/BB/C&M-3575/OT-24/RFx No. 5002003243/23-24 Schedule - 6
Construction of a Control Centre Building for OPTCL STAMS (State Transmission Asset Management System) Project by POWERGRID under Consultancy Services to OPTCL As per Lum-sum #DIV/0!
(SCHEDULE OF RATES AND PRICES : TYPE TEST CHARGES) AS per Percent 0.00%
As per lum-sum on Sch-7 #DIV/0!
#REF! To: As per Percent on Sch-7 0.00%
#REF! Contract Services Multipackage lum-sum #DIV/0!
Name : #REF! Power Grid Corporation of India Ltd., Multipackage on Percent 0.00%
Address : #REF! "Saudamini", Plot No.-2 Total Discount #DIV/0!
#REF! Sector-29, (near IFFCO Chowk)
#REF! Gurgaon (Haryana) - 122001
SL. NO. Description of Test Unit No. of Tests Unit Type Test Charges Total Type Test Charges Total Test Charges (Rs.)
#REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
Total Type Test charges: (A)+(B)+C) #REF! #REF!
Discount Sche-7 #REF!
Test Laboratory where the tests are proposed to be conducted [Indicate name and place of the test laboratory]
Date : #REF! Signature :
Place : #REF! Printed Name : #REF!
Designation : #REF!
This letter of discount is optional. Bidder may / may not offer any discount.
Specification No.: ODP/BB/C&M-3575/OT-24/RFx No. 5002003243/23-24 Letter of Discount
LETTER OF DISCOUNT
DY.GENERAL MANAGER(C&M)
POWER GRID CORPORATION OF INDIA LIMITED,
ODISHA PROJECTS
PLOT NO.-4, UNIT-41, NILADRI VIHAR
CHANDRASHEKHARPUR, BHUBANESWAR-751021
Subject : Construction of a Control Centre Building for OPTCL STAMS (State Transmission Asset Management System) Project by POWERGRID under Consultancy Services to OPTCL
With reference to the subject tender, we hereby offer unconditional discount on the prices quoted by us as per details given here below : Eq Weightage of Rs/ % Final Discount Factor
1 Discount on lum-sum basis on total price quoted by us without Taxes & Duties. [The discount shall be proportionately applicable on all the items of all the Schdules i.e. Sch-1 (without type test charges), Sch-2 & Sch-6] In Rs. #REF! #REF!
2 Discount on percent basis on total price quoted by us without Taxes & Duties. [The discount shall be proportionately applicable on all the items of all the Schdules i.e. Sch-1 (without type test charges), Sch-2 & Sch-6] In Percent (%) #REF! 0.00%
3 Discount on lum-sum basis on the Schedules as given below : [The discount shall be proportionately applicable on all the relevent items of the respective Schdules.] In Rs.
Schedule-1 : Ex works prices (Direct Only) In Rs. #REF! #REF! Schedule-1 : (Direct Only) #REF!
Schedule-1 : Ex works prices (Bought Out Only) In Rs. #REF! #REF! Schedule-1 : (Bought Out Only) #REF!
Schedule-2 : Freight & Insurance In Rs. #REF! #REF! Schedule-2 : Freight & Insurance #REF!
Schedule-3 : Erection Charges In Rs. 0.0000000000% Schedule-3 : Erection Charges
Schedule-6 : Type Test Charges In Rs. #REF! #REF! Schedule-6 : Type Test Charges #REF!
4 Discount on percent basis on the Schedules as given below : [The discount shall be proportionately applicable on all the relevent items of the respective Schdules.] In Percent (%)
Schedule-1 : Ex works prices (Direct Only) In Percent (%) #REF! 0.00%
Schedule-1 : Ex works prices (Bought Out Only) In Percent (%) #REF! 0.00%
Schedule-2 : Freight & Insurance In Percent (%) #REF! 0.00%
Schedule-3 : Erection Charges In Percent (%) 0.00%
Schedule-6 : Type Test Charges In Percent (%) #REF! 0.00%
Discount(s) offered at sl. No. 1 to 4 will automatically get displayed and accounted for in the respective items of the Schedules. #REF! #REF!
5 We hereby offer Multi-package discount as given below:
Please consider this letter of discount as the integral part of our price bid.
Thanking you, we remain,
Yours faithfully,
Date : #REF! Printed Name : #REF!
Place : #REF! Designation : #REF!
Details of Octroi
Sl No. Description of Items Amount on which Octroi is applicable Rate of Octroi Octroi
Details of Entry Tax
Sl No. Description of Items Amount on which Entry Tax is applicable Rate of Entry Tax Entry Tax
Details of Other Taxes & Duties
Sl No. Description of Items Amount on which Other Taxes & Duties are applicable Description of Taxes & Duties Rate of Taxes & Duties Amount of Taxes & Duties
Specification No.: ODP/BB/C&M-3575/OT-24/RFx No. 5002003243/23-24 Bid Form 2nd Envelope 0 1 st 1 January
#REF! 2 nd 2 February
BID FORM (Second Envelope) 3 rd 3 March
Bid Proposal Ref. No. 5 th 5 May
Date : 00/Jan/00 6 th 0 6 June
To: 8 th January 8 August
Sr.GENERAL MANAGER 9 th 1900 9 September
POWER GRID CORPORATION OF INDIA LIMITED, 10 th 10 October
ODISHA PROJECTS 11 th 11 November
PLOT NO.-4, UNIT-41, NILADRI VIHAR 12 th 12 December
CHANDRASHEKHARPUR, BHUBANESWAR-751021 13 th
Name of Contract : Construction of a Control Centre Building for OPTCL STAMS (State Transmission Asset Management System) Project by POWERGRID under Consultancy Services to OPTCL 15 th
Dear Ladies and/or Gentlemen, 16 th
1.0 In continuation of First Envelope of our Bid, we hereby submit the Second Envelope of the Bid, both of which shall be read together and in conjunction with each other, and shall be construed as an integral part of our Bid. Accordingly, we the undersigned, offer to supply goods as per provision of Technical Specification) under the above-named package in full conformity with the said Bidding Documents for the sum of Rs. or such other sums as may be determined in accordance with the terms and conditions of the Bidding Documents. In continuation of First Envelope of our Bid, we hereby submit the Second Envelope of the Bid, both of which shall be read together and in conjunction with each other, and shall be construed as an integral part of our Bid. Accordingly, we the undersigned, offer to supply goods as per provision of Technical Specification) under the above-named package in full conformity with the said Bidding Documents for the sum of Rs. or such other sums as may be determined in accordance with the terms and conditions of the Bidding Documents. #REF! #REF! 17 th
Schedule 1A to 1O Supply of Services 21 st
Schedule 2() Taxes and Duties. 22 th
Schedule 3() Summary. 0 23 th
Schedule 4() Taxes and Duties not included in Schedule 1 to 3 24 th
Schedule 5() Grand Summary [Schedule 1 to 4] 25 th
Schedule 6() Break-up of Type Test Charges for Type Tests to be conducted-Not applicable
2.5 We declare that items left blank in the Schedules will be deemed to have been included in other items. The TOTAL for each Schedule and the TOTAL of Grand Summary shall be deemed to be the total price for executing the Facilities and sections thereof in complete accordance with the Contract, whether or not each individual item has been priced. 31 st
3.0 We confirm that except as otherwise specifically provided our Bid Prices in this Second Envelope include all taxes, duties, levies and charges as may be assessed on us, our Sub-Contractor/Sub-Vendor or their employees by all municipal, state or national government authorities in connection with the Facilities, in and outside of India.
3.1 100% of applicable Taxes and Duties i.e GST, which are payable by the Purchaser under the Contract, shall be reimbursed by the Purchaser on production of satisfactory documentary evidence by the Supplier in accordance with the provisions of the Bidding Documents.
3.3 We confirm that we have also registered/we shall also get registered in the GST Network with a GSTIN , in all the states from which we shall make our supply of goods.
4.0 # (For Joint Venture only) We, the partners of Joint Venture submitting this bid, do agree and confirm that in case of Award of Contract on the Joint Venture, we shall be jointly and severally liable and responsible for the execution of the Contract in accordance with Contract terms and conditions.
4.0 We, hereby, declare that only the persons or firms interested in this proposal as principals are named here and that no other persons or firms other than those mentioned herein have any interest in this proposal or in the Contract to be entered into, if the award is made on us, that this proposal is made without any connection with any other person, firm or party likewise submitting a proposal is in all respects for and in good faith, without collusion or fraud.
Thanking you, we remain,
Yours faithfully,
For and on behalf of
Date : 00/Jan/00 Printed Name : 0
Place : 0 Designation : 0
Please provide additional information of the Bidder
Business Address :
Country of Incorporation :
State/Province to be indicated :
Name of Principal Officer :
Address of Principal Officer :
STATEMENT OF QUOTED / CORRECTED PRICES
All Figures are in Rupees
Sl. No. Price Component Quoted Price Corrected Price
1 TOTAL SCHEDULE NO. 1:Ex-Works Price of Plant and Equipment including Type Test Charges 0.00 0.00
2 TOTAL SCHEDULE NO.2: Local Transportation, Insurance and other Incidental Services. 0.00 0.00
3 TOTAL SCHEDULE NO.3: Installation Charges 0.00 0.00
4 TOTAL SCHEDULE NO.4: Training Charges Not Applicable Not Applicable
5 TOTAL BID PRICE: (Excluding Taxes & Duties) 0.00 0.00
6 DISCOUNT #REF! #REF! #REF!
7 NET BID PRICE (Excluding Taxes & Duties) #REF! #REF!
8 TAXES & DUTIES PAYABLE ADDITIONALLY
A) EXCISE DUTY #REF! #REF!
B) CENTRAL SALES TAX #REF! #REF!
C) VAT #REF! #REF!
D) ENTRY TAX / OCTROI #REF! #REF!
E) OTHERS #REF! #REF!
F) TOTAL TAXES & DUTIES #REF! #REF!
8 TOTAL BID PRICE (INCLUDING TAXES & DUTIES) #REF! #REF!
9 TOTAL SCHEDULE NO.7: Type Test Charges [Total of this Schedule is included in Schedule-1 above] #REF! #REF!
I) Bidder has indicated the following taxes and duties additionally applicable for their bid:
#REF! #REF! Excise Duty #REF! #REF! #REF! #REF!
#REF! 1.28 CST #REF! #REF! #REF! #REF!
#REF! #REF! VAT #REF! #REF! #REF! #REF!
#REF! #REF! Entry Tax/ Octroi #REF! #REF!
#REF! #REF! Others #REF! #REF!
II) With regard to Entry Tax, it may be mentioned that the substations covered under the subject pacakge falls in State of MP, where an entry tax @ 2% of Purchase Price is applicable. In view of the above, the taxes and duties inter-alia including entry tax applicable for the bids are calculated :
a) Ex-Works Price of Direct Supplies (after discount, if any) Rs. #REF!
b) Excise Duty, as applicable on (a) above at the rate : 10.30% Rs. #REF!
c) Amount on which Sales Tax is applicable #REF! #REF!
d) CST, as applicable on (a) + ED (b) above at the rate : 0.00% Rs. #REF!
e) VAT, as applicable on (a) + ED (b) above at the rate : 0.00% #REF!
f) Others [……………………………………………] Rs. #REF!
g) Purchase Price for Entry Tax (Total Ex-Works+F&I+ED+CST+Others) Rs. #REF!
h) Entry Tax, as applicable on (e) above at the rate : Rs. #REF!
Construction of a Control Centre Building for OPTCL STAMS (State Transmission Asset Management System) Project by POWERGRID under Consultancy Services to OPTCL Statement of Quoted / Corrected Prices Page
#REF! Excise Duty #REF! #REF! #REF! #REF!
Sl. No. Clause Ref. No. Description of Clause Observation/ Comment of the Bidder Remarks 128% CST #REF! #REF! #REF! #REF!
1 Clause 10 Taxes and Duties, Section-IV, GCC 10. Taxes and Duties #REF! VAT #REF! #REF! #REF! #REF!
10.1 The Supplier shall be entirely responsible for payment of all taxes, duties, licence fees ………………………. #REF! #REF! Entry Tax/ Octroi #REF! #REF!
10.2 The Supplier shall be solely responsible for the taxes that may be levied on the Supplier's persons ……………………….. #REF! #REF! Others #REF! #REF!
10.3 In respect of direct transaction between the Purchaser and the Supplier, the EXW price is inclusive………………………….. #REF!
10.4 Octroi/entry tax as applicable for destination site/state on all items of supply including bought-out finished items, which shall be dispatched directly from the …………………………………… #REF!
10.5 Purchaser would not bear any liability on account of Service Tax. ………………. #REF!
10.6 Sales Tax/VAT on Works Contract, Turnover Tax or any other similar taxes under the …………………………………..
10.7 For the purpose of the Contract, it is agreed that the Contract Price specified in Article 2(Contract Price and Terms of Payment) of the Contract Agreement is based on the taxes, duties, levies and charges prevailing at the date seven (07) days prior to the last date of bid submission (hereinafter called “Tax” in this GCC Sub-clause 10.7). .……………........................................
In respect of raw materials, intermediary components etc and bought out items, neither the Purchaser nor the Supplier shall be entitled to any claim arising due to increase or decrease in the rate of Tax, ……………………………………………....
2 Clause 29 Change in Laws and Regulations, Section-IV, GCC 29.1 If, after the date seven (07) days prior to the date of Bid Opening, any law, regulation, ordinance, order or by-law having the force of law is enacted, promulgated, abrogated or changed in India (which shall be deemed to include any change in interpretation or application by the competent authorities) ……………………………………….
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
23 Twenty Three
27 Twenty Seven
28 Twenty Eight
33 Thirty Three
37 Thirty Seven
38 Thirty Eight
73 Seventy Three
74 Seventy Four
75 Seventy Five
77 Seventy Seven
78 Seventy Eight
79 Seventy Nine
83 Eighty Three
87 Eighty Seven
88 Eighty Eight
93 Ninety Three
97 Ninety Seven
98 Ninety Eight
100 One Hundred
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html
Attachment 20- MII.DOCX
docx • 0.02 MB
Attachment-21_Certificate by Auditor-PPP-MII.docx
docx • 0.02 MB
Attachment-26 Declaration to ITB 3.1.docx
docx • 0.03 MB
Attachment-27 Restrictions under GFR.doc
doc • 0.04 MB
Attachment-28 - Compliance to DMI & SP Policy.doc
doc • 0.04 MB
Attachment-29 KMP 3T-B.docx
docx • 0.03 MB
Attachment-30 Undertaking - Hard copy part of the bid.docx
docx • 0.03 MB
Attachment-31 Bid Securing Declaration.docx
docx • 0.02 MB
First Envelope and Bid Forms.xlsx
xlsx • 0.37 MB
01-_SITE_LAYOUT_PLAN-01-04-2023.pdf
pdf • 0.33 MB
02-GROUND_FLOOR_PLAN-01-04-2023.pdf
pdf • 0.30 MB
03-FIRST_FLOOR_PLAN-01-04-2023.pdf
pdf • 0.41 MB
04-SECOND_FLOOR_PLAN-01-04-2023.pdf
pdf • 0.22 MB
05-_THIRD_FLOOR_PLAN-01-04-2023.pdf
pdf • 0.23 MB
Front Elevation_.pdf
pdf • 0.06 MB
left side elevation.pdf
pdf • 0.06 MB
Rear Elevation.pdf
pdf • 0.06 MB
right side elevation.pdf
pdf • 0.06 MB
Section A2-A2.pdf
pdf • 0.06 MB
Section-A-A.pdf
pdf • 0.07 MB
3_ARCHITECTURAL FLOOR PLANS.PDF
pdf • 3.04 MB
4_Standard Field Quality Plan Revision 04.pdf
pdf • 2.80 MB
5_Indicative make list.xlsx
xlsx • 0.02 MB
6_QR for Sub Vendors.pdf
pdf • 0.42 MB
0_COVER_PAGE.docx
docx • 0.69 MB
10_Technical Specification_PT Beam Slabs.doc
doc • 0.03 MB
1_GENERAL_SPECIFICATION_Revised.docx
docx • 0.09 MB
2_TS_-_Internal_Electrification-3.docx
docx • 0.29 MB
3_TECHNICAL_SPECIFICATION_-_FFPS.doc
doc • 0.54 MB
4_TECHNICAL_SPECIFICATIONS_-_HVAC_SYSTEM.doc
doc • 0.45 MB
5_TECHNICAL_SPECIFICATIONS_-_LIFT.doc
doc • 0.32 MB
6_TECHNICAL_SPECIFICATIONS_-_SOLAR.doc
doc • 0.24 MB
7_TECHNICAL_SPECIFICATIONS_-_SIGNAGES.doc
doc • 0.20 MB
8_TECHNICAL_SPECIFICATIONS_-__PHE_WORKS.doc
doc • 1.08 MB
9_Civil Works Rev 11A.pdf
pdf • 2.00 MB
GARPTS.pdf
pdf • 0.05 MB
Price_Schedule.xlsx
xlsx • 0.59 MB
01 Invitation for Bids (IFB)-Section-I.doc
doc • 0.40 MB
02 Instructions to bidders(ITB)-Section-II.pdf
pdf • 0.55 MB
03 Bid Data Sheets (BDS)-Section-III.doc
doc • 0.37 MB
03A Annexure A (BDS) QR.doc
doc • 0.28 MB
03B ANNEX-B (BDS) eRA.docx
docx • 0.02 MB
03C_Annexure-C (BDS)-eRA.doc
doc • 0.32 MB
03D ANNEX-D(BDS)-Undertaking.DOC
doc • 0.05 MB
03E ANNEX-E (BDS) Sample E-stamp paper.pdf
pdf • 0.08 MB
04 Conditions of Contract Civil Works-Section-IV.pdf
pdf • 0.39 MB
04A GCC Civil Amendments I - X.pdf
pdf • 3.64 MB
05 SCC-Section-V.docx
docx • 0.11 MB
06 Sample Forms & Procedures to SCC - Section-IV.docx
docx • 0.05 MB
06A Annex-I to SCC_Activity wise completion & Payment Terms.pdf
pdf • 0.14 MB
06B Annex-II to SCC_Price Variation.docx
docx • 0.02 MB
RFx_Extn-V.pdf
pdf • 0.02 MB
1 Annexure-I_PDDL.pdf
pdf • 0.47 MB
Clar-I-Extn-IV.pdf
pdf • 0.39 MB
RFx_PDF_Extension-III.pdf
pdf • 0.02 MB
0 Amendment- Letter.docx
docx • 0.19 MB
Amendment.docx
docx • 0.19 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .