Tender Value
₹28 L
EMD Value
₹56,000
Closing Date
26 Aug 2022, 6:00 pmClosed
Shri TKM Rambhal, EE
GE (West) Mathura
Comprehensive repair/maint of STP, Equipment etc and other connected items under GE(W) Mathura
2022_MES_540675_1
8300/1088/E8
Open Tender
Civil Works
Item Rate
180 days
Mathura Cantt
As per tender documents
9 documents required · 9 mandatory
₹500
GE (West) Mathura
₹56,000
Yes
22 Oct 2022
30 Jul 2022
2 Sept 2022
30 Jul 2022
26 Aug 2022
13 Aug 2022
Amount
M&L for cleaning of oxidation pond of size 78.50Mtr x 32.50 Mtr,by any means including following works :- (a) Extracted sludge/soil to be buried in the ground to a distance of 50 Mtr away from the oxidation pond all as specified and directed. (b) Cleaning of vegitation around the oxidation pond.
Taking down old unservicable butter fly valve and supply and fixed new CI body butter fly valve half round type ISI marked including nuts, bolts, joint, rubber insertion sheet complete all as specified and directed by Engineer in Charge of following sizes :- (a) 50mm dia.
(b) 65mm dia.
(c) 80mm dia.
(d) 100mm dia.
M&L for in repair /maintenance of Electronic LT Panel by complete replacement of the following items with new itmes all as specified and directed. Note :Repair of LT panel will be carried out only once but after repair/ maintenance of panel made to be functional is responsibility of contractor in all respect without any extra cost. Loc :- 1 CSR KLP (a) MCCB 250 Amps 36 KVA
(b) Isolator 4 pole, 40 Amp, 415 Volts
(c) MCB SP 16 Amp, 240 Volts, C series
(d) Ampere meter digital 0 to 100 Amp
(e) Volt meter digital 0 to 500 Volt
(h) Power contactor MNX 20
(j) Power contactor MNX 10
(k) Auxiliary switch
(l) Single phase preventer
S&F in replacement of cable PVC flexible with copper conductor of size 2.5 Sqmm single core complete all as specified and directed.
S&F in replacement of cable submersible flat with copper conductor of size 10 Sqmm 3 core complete all as specified and directed.
S&F in replacement of cable submersible flat with copper conductor of size 6 Sqmm 3 core complete all as specified and directed.
Dismantling & lifting of submersible sewage pump set up to 10 HP motor & pump from sewage well including draining out sewage water by providing additional portable moveable Diesel engine /submersible including, transporting to civil workshop for repairing, dismantling of pump & motor re-assembling after complete repairing and carrying back to sewage installation,again dewatering the pump with same pumping process lowering, installing & connecting with existing system and testing on load complete all as specified and directed. Note : (a) Photographs with date and time of all activities such as dismantling and lifting and lowering of pumps will be taken during currency of work and forwarded alongwih any payment claimed by contractor and cost to this effect shall be deemed to be included in the quoted rates..
(b) If there is any defects during liability period , the same will be repaired by the contrator and alternate arrengment of submersible pump and motor will be made without hampering the function of STP. if conntractor is failed to provid alternate arrengment till repair of defective pump set, a penality of Rs 1000/- per day will be levied till functioning of STPs/Sewage pumping station. (c) Submersible sewage pump set taken to civil workshop shall be issued on proper gate pass and received back after repair on proper challan are mandatory and entries of repair should be made in log book and to be produced at the time of payment.
M&L for rewinding of submersible sewage pump motor set of capacity 10 HP, three phase 415 volts, 50Hz AC with super enameled copper winding wire of existing size and gauge including insulating material, heating drying, replacement of ball bearing, assembling and testing complete all as specified and directed.
Dismantling of non clog submersible sewage pump of 10 HP capacity (Make : Kirloskar) and complete repairing including replacement of CI impeller as per suitable size, bearings and mechanical seal complete all as specified and directed.
S&F in replacement of oil seal suitable for submersible sewage pump motor of capacity 10HP , three phase 415 Volts , 50 Hz AC motor complete all as specified and directed.
M&L for rewinding of submersible sewage pump motor of capacity 7.5 HP, three phase 415 volts, 50Hz AC with super enameled copper winding wire of existing size and gauge including insulating material, heating drying, replacement of ball bearing, assembling and testing complete all as specified and directed.
Dismantling of submersible sewage pump of 7.5 HP capacity (Make : Kirloskar) and complete repairing including replacement of CI impeller, bearing, mechanical seal, re-assembling and testing complete all as specified and directed.
Dismantling of submersible sewage pump of 5 HP capacity and complete repairing including replacement of CI impeller, bearing, re-assembling and testing complete all as specified and directed.
S&F in replacement of oil seal suitable for submersible sewage pump motor of capacity 7.5HP , three phase 415 Volts , 50 Hz AC motor complete all as specified and directed.
M&L for rewinding of submersible sewage pump motor of capacity 5.0 HP, three phase 415 volts, 50Hz AC with super enameled copper winding wire of existing size and gauge including insulating material, heating drying, assembling and testing complete all as specified and directed.
Dismantling of unsv. non clog submersible sewage pump of 5.0 HP capacity (Make : Kirloskar) and complete repairing including replacement of bronze impeller, bearing, mechanical seal, re-assembling and testing complete all as specified and directed.
S&F in replacement of oil seal suitable for submersible sewage pump motor of capacity 5.0 HP , three phase 415 Volts , 50 Hz AC motor complete all as specified and directed.
Dismantling of air blower with 10 KW/15 KW electric motor from STP (Lohara Marg), STP 1 CSR transporting to civil workshop for repairing, dismantling of blower & motor re-assembling after complete repairing and carrying back to STP installation & connecting with existing system and testing on load complete all as specified and directed by Engineer-in-Charge. Note: rewinding if required shall be measured and paid separately
M&L for rewinding of air blower motor of capacity 10 KW, three phase 415 volts, 50Hz AC with super enameled copper winding wire of existing size and gauge including insulating material, heating drying, re-assembling and testing complete all as specified and directed.
M&L for repairing of air blower of capacity 10 KW, including replacement of ball bearing both DE & NDE sides, lubricating oil, re-assembling and testing on load complete all as specified and directed.
M&L for repairing of air blower compressor of capacity 10 KW, including replacement of piston ring set, crank shaft and filling up of compressor oil complete re-assembling and testing on load complete all as specified and directed.
M&L for repairing of air blower compressor of capacity 15 KW, including replacement of piston ring set, crank shaft and filling up of compressor oil complete re-assembling and testing on load complete all as specified and directed.
M&L for rewinding of air blower motor of capacity 15 KW, three phase 415 volts, 50Hz AC with super enameled copper winding wire of existing size and gauge including insulating material, heating drying, re-assembling and testing complete all as specified and directed.
M&L for repairing of air blower of capacity 15 KW, including replacement of ball bearing both DE & NDE sides, lubricating oil, re-assembling and testing on load complete all as specified and directed.
Dismantling of treated water mono block pump with 5.0 HP electric motor from STP(Lohara Marg/ 1CSR KLP), transporting to civil workshop for repairing, dismantling of blower & motor re-assembling after complete repairing and carrying back to STP installation & connecting with existing system and testing on load complete all as specified and directed. Note: rewinding if required shall be measured and paid separately.
M&L for rewinding of treated water mono block pump motor of capacity 5.0 HP, three phase 415 volts, 50Hz AC with super enameled copper winding wire of existing size and gauge including insulating material, heating drying, re-assembling and testing complete all as specified and directed.
Draining out complete sewage water from main receiving sump, cleaning out the bottom surface of sump including disconnecting and taking out of sewage submersible pump 3 Nos complete with suction pipe complete all as specified and directed.
M&L for MS pipe 100mm dia including fixing with sewage submersible pump set separate suction line for each pump set (03 Nos pump set) including connection to submersible pump testing on completion complete all as specified and directed.
Supply and Mix liquid chlorine sodium hypo solution 6% free chlorine based granular disinfectant for water teatment manually, much more stable than chlorine gas and stronger than bleaching powder complete all as specified and directed.
Taking down security light fittings / bulkhead/mirror /post top/ garden / under water/ light fittings of any description omplete all as specified and directed.
S&F security light fixture Endura city liner 24 IP 70 LED 6000K 72watts including connection with pre insulated GI pipe 32mm dia light grade with clamps and copper conductor cord flexible of size 23/0.0076 3 core complete all as specified and directed.
M&L for scraping old paint from steel tubular swan neck pole of 8.5m long or above and painting the same with one coat of synthetic water proof paint of existing colour complete all as specified and directed.
S&F pole mounted terminal box of size 300x200x105mm (In side dimension) including MCB SP 6 Amps, C series 4 Nos, aluminium bus bar of 25mmx3mm thick fixed on prcelain post insulators with hinged cover and locking arrangement fixed to electric pole by means of MS flat iron 25x6mm with bolts and nuts complete all as specified and directed.
S&F building Security Light of 40 watts of new generation energy saving & environmental friendly long life Versatile pressure die-cast aluminium IP66 roadway luminaire with high power LED as light source with acrylic cover and accessories, complete all as specified and directed.
S&F Post Top Lantern into Integrated Solar Street Light - 16 Watts the system shall include FRP housing Hi-brightness W-LED (120-140 lumens per watt) operating voltage 11.1/12.8V, IP-65 complaint driver efficieny 85% to 90% CRI > 70 CCT 5000 to 6500 kelvin toughen glass/acrylic cover MPPT/PWM base charge controller with hi-efficency LED driver designed with/without dimming function as per IEC complaint Hi-efficiency 28/30 WP Mono crystalline Solar Panel, 15.4 AH Lithium battery - DOD 90 to 95% with inbuilt PCB as per BIS complaint dusk to down operation working temperature (-) 10 degree C to (+) 55 degree C, weight 6-7 kg with adjustable powder coated MS clamp suitable for pole/wall mounting protection short circuit, over load reverse polarity and battery protection complete with GI iron pipe 65 mm dia, medium grade, 5 mtr high excluding 1 mtr planting depth with aluminium painted foundation of pole with PCC (1:3:6) using 20 mm graded stone aggregate of size 450 x 450 x 1000 mm deep including earthwork complete all as specified and directed.
M&L for Scraping old paint from MS pipe of size 150mm dia, painting the same with one coat of synthetic water proof paint of existing colour complete all as specified and directed.
M&L for Scraping old paint from MS pipe of size 100mm dia, painting the same with one coat of synthetic water proof paint of existing colour complete all as specified and directed.
M&L for Scraping old paint from MS pipe of size 80mm dia, painting the same with one coat of synthetic water proof paint of existing colour complete all as specified and directed.
M&L for Scraping old paint from compressor,painting the same with one coat of synthetic water proof paint of existing colour complete all as specified and directed.
M&L for Scraping old paint from water circulating pump, painting the same with one coat of synthetic water proof paint of existing colour complete all as specified and directed.
M&L for Scraping old paint from MS ladder of size not more than 20 feet long, painting the same with one coat of synthetic water proof paint of existing colour complete all as specified and directed.
Labour only for checking the leakage of water supply UPVC pipe lines ,valves ,stand post and allied fittings of 15mm dia to 75 mm dia from STP Lohara marg and 1 CSR KLP STP to land scape gardens ,children park etc area approx 15 Km and make proper report on record duly signed by concern JE E/M and Engineer-in-Charge.
Supply, laying, testing and commissioning cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, elecric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 16 sqmm 4 core including taking out old unserviceable cable complete all as specified and directed.
Supply & laying 150mm bore cast iron pipes with spigot and socketed end centrifugally cast class LA, in any length laid in trenches including taking out old unservicable CI pipe, burning out joints and recovering lead complete all as specified and directed.
Supply & laying 100mm bore cast iron pipes with spigot and socketed end centrifugally cast class LA, in any length laid in trenches including taking out old unservicable CI pipe, burning out joints and recovering lead complete all as specified and directed.
Supply & laying 80mm bore cast iron pipes with spigot and socketed end centrifugally cast class LA, in any length laid in trenches including taking out old unservicable CI pipe, burning out joints and recovering lead complete all as specified and directed.
S&F CI fittings upto 150mm dia all socketed or socket and spigot such as bends, tapers, tee pieces, Y- junction for spigot and socketed pipe complete all as specified and directed.
M&L for run lead joint 150mm dia CI pipe, using 50% old lead (retrieved while taking out old lead joint), spun yarn, complete all as specified and directed.
M&L for run lead joint 100mm dia CI pipe, using 50% old lead (retrieved while taking out old lead joint), spun yarn, complete all as specified and directed.
M&L for run lead joint 80mm dia CI pipe, using 50% old lead (retrieved while taking out old lead joint), spun yarn, complete all as specified and directed.
Excavation in trenches, not exc. 1.5 mtr wide and n.exc 1.5 Mtr deep for laying sewage pipe including forming bottom surface at required gradient & getting out in soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc. 25 cm each layer in soft/loose soil complete all as specified and directed.
Removing excavated material n.exc 50 mtr and depositing where directed at a level not exc. 1.5 mtr above the starting point in soft/loose soil complete all as specified and directed.
M&L for sand cushioning and covering clean and dry sand to underground electric cable with 8 cm before laying and 10 cm over the cable including ramming complete all as specified and directed. Note :- Punned thickness shall be measured and paid for.
M&L for sub class 'B' brick laid dry, flat with width equal to length of brick as cover laid over the cabel to give mechanical protection to underground cabels complete all as specified and directed.
S&F in repair of PVC hose pipe heavy duty 80 mm dia suitable for non clog pump & motor connection of drain out pipe complete all as specified and directed.
S&F in repair/replacement of star-delta starter for 5.0 HP capacity mono block pump set including all necessary arrangement and testing complete all as specified and directed.
S&F in repair/replacement of star-delta starter for 10.0 HP capacity mono block pump set including all necessary arrangement and testing complete all as specified and directed.
S&F in repair/replacement of star-delta starter for 10.0 HP capacity Submersible Non clog pump set including all necessary arrangement and testing complete all as specified and directed.
S&F in repair of nylon rope 25mm dia complete all as specified and directed.
Collecting of treated water samples from STP 1CSR KLP cap 800 cum/day at RATC & STP Lohara marg cap 300cum/day get the water tested from NABL Lab/Govt Lab for Bacteria test & carried out inspection of STP plant from OEM (Authorized company) & getting collection of certificate complete all as specified & directed by Engineer-in-charge. Note - Cost of testing charges shall also be borne by the contractor and same is deemed to be included their quoted rate.
Supply, laying, testing and commissioning cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, elecric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 240 sqmm 3.5 core including taking out old unserviceable cable complete all as specified and directed.
S&F in replacement of automatic changeover switch with sheet metal enclosure of capacity 250 Amps, 415 V, 50 Hz, modular construction, 4 pole, door interlock, frame 250A ATS fitted enclosure with electrical connection, lugs, thimbels etc. required at site complete all as specified and directed.
Supplying, fixing, jointing and testing of CI sluice valve of 200 mm dia class PN 1.6 flanged ends, heavy duty, long body, with steel spindle, ISI marked, (conforming to IS-780 or latest revised) suitable for the following bore of pipes including taking out old sluice valve complete all as specified and directed
Supplying, fixing, jointing and testing of CI sluice valve of 150 mm dia class PN 1.6 flanged ends, heavy duty, long body, with steel spindle, ISI marked, (conforming to IS-780 or latest revised) suitable for the following bore of pipes including taking out old sluice valve complete all as specified and directed
Supply and laying new electrical insulation rubber matting as per ISI and size 1mtrx 2mtr x 19mm suitable for electric installations/ panel boards tested suitable complete all as specified and directed.
M&L for in repair/replacement contactor MNX 95 including fixing of all necessary connections complete all as specified and directed.
M&L for in repair/replacement contactor MNX 80 including fixing of all necessary connections complete all as specified and directed.
S&F in replacement of mechnical chlorine dosing plant high pressure single head adjustable granular chlorine dosing system and chlorination doser pump with mixing tank for calcium hypo chloride 65 to 70% including connecting pipe complete all as specified and directed with following items : (a) Adjustable High pressure 5 Kg/Sqcm power input 230 V 50 Hz, 40 SPM 1/3 frictional HP, max output 10 Ltr/hr. (b) Preparation Tank of net capacity of 100 Ltrs FRP. (c) 200 Ltr FRP dosing tank with gauge agitator 120 watt 900 mm SP range mounted with plastic shaft and impeller including Service tank and all assessories.
S&F in replacement PVC insulated and unsheathed multistrand copper conductor cables 1100 volts grade of size 50 sqmm single core complete all as specified directed.
ASHOK INFRATECH
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .