Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.2 LAccepted-AOC 94 PHASE II HOUSEING COLONY UDHAMPUR J K | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹30.0 L+₹65,909.50 (2.25%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹30.9 L+₹1.6 L (5.46%)Rejected-AOC 21 JHAMRI 151 JHAMRI JHAMRI ROHTAK HARYANA 124142 UDYAM HR 07 0030314 | JHAJJAR | HARYANA | 124142 | L3 | Rejected-AOC Rejected |
Tender Value
Refer Docs
EMD Value
₹67,000
Closing Date
14 Dec 2020, 6:00 pmClosed
SHUBHAM PRAKASH
GE (NORTH) UDHAMPUR
GE/U(N)-64/2020-21 ADDN/ALT TO BLDG NO P 70 OF NO 2 CT AND IS DETT PROVN OF BPL CHECKING GANTRY AT FPD AND PROVN OF IRON SHED AT FSD INCLUDING CERTAIN REVENUE WORKS UNDER AGE B/R-II OF GE (NORTH) UDHAMPUR
2020_MES_395902_1
GE/U(N)-64/2020-21
Open Tender
Civil Works
Item Rate
180 days
UDHAMPUR
CLASS D
7 documents required · 7 mandatory
₹500
GE (NORTH) UDHAMPUR
₹67,000
Yes
5 Jan 2021
17 Nov 2020
16 Dec 2020
17 Nov 2020
14 Dec 2020
30 Nov 2020
Amount
Excavation in trenches for any type of soil n.exe. 1.50m is deep and n.exe 1.50 wide and getting out , complete all as specified and as directed by Engr-in-Charge.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm, complete all as specified and as directed by Engr-in-Charge.
Removing excavated material to a distance n exc 50 m and depositing where directed at a level n exc 1.5 m above the starting point,returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm, complete all as specified and as directed by Engr-in-Charge.
Hard core of broken stones/ boulders of gauge not exc 63mm deposited spread & levelled in layers n exc 15 cm thick watered and rammed to a true surface all as spd & dir.
Brick work with subclass ‘B’ old size burnt bricks, straight or curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified and directed by Engineer-in-Charge..
Brick work with sub class ‘B’ bricks (old size), straight or curved on plan to any radius in half brick thick walls built in CM 1:4 , complete all as specified and directed by Engineer-in-Charge.
Brick work with subclass ‘B’ old size burnt bricks, straight or curved on plan exc 6m mean radius built in cement mortar (1:4) complete all as specified and directed by Engineer-in-Charge..
Reinforced cement concrete (design mix) M-25( using 20mm graded crushed stone aggregate) in foundations including rafts, footings, foundation beams, plinth beams, bases for columns etc basement slabs, under reamed piles and mass concrete complete all as specified and directed by Engineer-in-Charge.
Reinforced cement concrete (design mix) M-25( using 20mm graded crushed stone aggregate) as in columns, pillars, piers, posts & struts etc complete all as specified and directed by Engineer-in-Charge.
Reinforced cement concrete(design mix) M-25( using 20mm graded crushed stone aggregate) as in beams, cantilevers, bressummers, lintel over 1.5m clear span complete all as specified and directed by Engineer-in-Charge.
RCC M-25 design mix in slabs, Shelves, complete all as specified and as directed by Engr-in-Charge.
RCC type B1 (1:2:4) Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in the shelves and the like including 15 mm th plastering with water proofing compound as directed laid/made to slope as in RCC roof surfaces complete all as directed .
RCC type B1 (1:2:4) as in columns, pillars etc all as specified & directed by Engr-In-Charge.
Mild steel TMT bars 8mm dia and over, cut to length, bent to shape required, including cranking , bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed by Engineer-in-Charge.
TMT steel bars, 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with MS wire (annealed not less than 0.9mm dia), complete all as specified and directed by Engineer-in-Charge.
Use & waste of Form work to sides of concrete foundation, footings, bases of columns raft and raft beams, side and soffits (if any) of foundation and plinth beams, and similar work vertical or to batter for flat rough finished surfaces complete all as specified and directed by Engineer-in-Charge.
Use & waste of Form work to sides of pillars, posts, struts, pears and stanchion square or rectangle or polygonal for rough finished surfaces complete all as specified and directed by Engineer-in-Charge.
Use & waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. with rough finished surfaces of concrete, complete all as specified and directed by Engineer-in-Charge.
Use and waste of form work to soffits of suspended slab such as roof slab, floor slabs, landings, chajjas and similar work not exceeding 200 mm thick horizontal or sloping, flat rough finished surface of concrete, complete all as specified and as directed by Engr-in-Charge.
Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide complete all as specified and as directed by Engr-in-Charge
15mm thick rendering on fair faces of brick work or concrete surface in CM 1:6 finished even and smooth without using extra cement, complete all as specified and as directed by Engr-in-Charge.
Rendering 15 mm thick on fair faces of brick work or concrete surfaces, finished even and smooth (without using extra cement) on walls in cement mortar (1:4), including integral WPC by wt of cement as per manufacturer instruction (NOTE : Supply only WPC will be measured and paid for separately), complete all as specified and directed by Engr-in-charge.
Rendering 10mm thick on fair face of brick work or concrete surfaces CM (1:6) complete all as specified and directed by Engineer-in-Charge.
Rendering 5 mm thick on fair faces of concrete surfaces, finished even and smooth on ceiling,roof projection,chajja in cement mortar (1:3), complete all as specified and directed by Engineer-in-Charge.
Cement concrete 75mm thick 1:4:8 type D2 using 40mm graded stone aggregate as in sub base to floors finished even and rough complete all as specified and directed by Engineer-in-Charge.
Material and labour for 50mm thick plain cement concrete type C-1 1:3:6(Using 20mm graded crushed stone aggregates) as in plinth protection finished fair and even without using extra cement complete all as specified and directed. Note : The plinth protection shall be laid in panels and length of the each panel shall not be more than 2.00 metre all as directed. 6mm joints filled with 85/25 grade bitumen and sand (1:3 ratio) shall be provided. .
50mm thick plain cement concrete type B-2 1:2:4(Using 20mm graded crushed stone aggregates) as in plinth protection finished fair and even without using extra cement complete all as specified and directed. Note : The plinth protection shall be laid in panels and length of the each panel shall not be more than 2.00 metre all as directed. 6mm joints filled with 85/25 grade bitumen and sand (1:3 ratio) shall be provided.
100 MM thick cement concrete type B-2 (1:2:4) 40mm graded agg laid as in floors complete all as specified and directed by Engineer-in-Charge
Forming Contraction (Dummy) joints 65mm deep x 10mm wide, filled with sealing compound complete all as specified and directed by Engineer-in-Charge
Machine pressed interlocking tiles of any shape and size of 80mm conf to IS-15658-2006. of grey colour complete all as specified and directed by Engineer-in-Charge
Machine pressed concrete interlocking paver block glossy finish, any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 grade with grey cement and pigment over 50mm thick sand cushion all as specified.
Sand cushioning 50mm thick under paver tiles complete all as specified and directed by Engineer-in-Charge
Earth filling under floors including watering and consolidation complete (earth shall be used from excavation free from vegetation, pebbelse/foreign materials complete all as directed by EIC
Supply only integral water proofing compound of approved quality, ISI Marked, complete all as specified and directed by Engineer-in-Charge.
Non skid ceramic coloured tiles 7 to 8mm thick (Square or rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, laid in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles with and including laying of 15 mm thick screed bed or bedding layer in CM 1:6 , complete all as specified and directed by Engir-In-Charge.
Glazed ceramic coloured tiles as per IS-13753, 300mm x 450 mm x 7 mm thick on vertical surfaces such as skirting /dado etc. set and jointed in neat cement slurry and pointed in white or colour cement to match over and including 10mm thick rendering in cement mortar 1:4 on fair faces of brick work or concrete surfaces as backing coat complete all as specified and directed by Engineer-in-Charge.
Machine cut kota stone slab flooring 18-20mm thick over 20 mm th cement screed in CM 1:3 base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed by Engr-in-Charge
Ditto but on skirting including backing coat 10 mm th in CM 1:3 completeall as specified & directed by Engr-in-Charge.
Vitreous china wash down water closet pedestal pattern white, (excluding flushing cistern and flush pipe) with 100mm CI ‘P’ or ‘S’ trap including sheet cover close pattern with flat bottom, CP jet and connection to trap and to flushing pipe etc fixed in repair , complete all as specified and directed by Engineer-in-Charge.
Supply and fixing 10 ltrs PVC flushing cistern low level (white) with inlet, ball valve float and handle including PVC Connection and 32mm dia PVC long bend for squar pattern etc. set with concrete and making good to floor including taking down, complete all as specified and as directed by Engr-in-Charge.
Grating doom 125 mm dia with waste hole of PTMT. (Minimum weight 40 gms) complete all as specified and as directed by Engr-in-Charge
Supply and fixing cast iron soil, waste and vent pipe 100mm dia bore (ISI Marked) sand cast pipes, in any length with or without ears, in cement joint, laid in trenches or fixed in walls etc, complete all as specified and directed.
Supply and fixing cast iron soil, waste and vent pipe 75mm dia bore (ISI Marked) sand cast pipes, in any length with or without ears, in cement joint, laid in trenches or fixed in walls etc, complete all as specified and directed.
Supply and fixing cast iron soil, waste and vent pipe 50mm dia bore (ISI Marked) sand cast pipes, in any length with or without ears, in cement joint, laid in trenches or fixed in walls etc, complete all as specified and directed.
CI floor trap 75mm dia with CI grating including jointing to waste pipe in run lead complete and making good the disturbed surface to match the existing surface, complete all as specified and directed.
Supply and fixing CI bend/Tee suitable for 100mm bore pipe (any radius), diminishing pieces or tapers ( larger bore measured ) wit oval acess door, fixed as in repairs complete all as specified and directed.
4 mm thick sheet glass ordinary quality and glazing with oil putty in squares not exc. 0.5 Sqm in each pane, complete all specified and as directed by Engineer-in-Charge.
Solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, in opening as per specifiecation and drawings.
Factory Made Solid PVC Moulded Door Shutters 28 to 30 mm thick (stile:), with 2,4 or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front Face & 2mm Plan colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing complete all as specified and as directed by Engr-in-Charge
Butt hinges, medium weight, stainless steel and fixed with screws, 100 mm size, ISI marked, complete all as specified and directed by Engineer-in-Charge.
150 mm size extruded aluminium handles cast type anodised , complete all as specified and directed by Engineer In Charge.
150mm Aluminium, anodised, barrel tower bolts of extruded section , complete all as specified and directed by Engineer In Charge.
Vitreous china wash hand basin white, flat back of size 550mmx400mm fixed on and including cast iron cantilever bracket, 32mm dia brass waste coupling and 32 mm dia PVC waste pipe including waste fitting etc fixed in repair , complete all as specified and directed by Engineer-in-Charge.
Towel Ring fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 90 gms) complete all as specified and as directed by Engr-in-Charge
Vitreous China Urinal, half stall type, white(excluding flushing cistern,flush pipe and waste pipe), with and including all fixing acessories in repairs., complete all as specified and directed by Engineer-in-Charge.
Supply and fixing PVC (SWR) gully trap of size 150 x 110 mm, setting and jointing with solvent cement complete all as specified & directed.
Preparing plastered or unplastered new decorated surfaces of walls and applying two coat of oil bound distemper over one coat of birla wall care putty all as specified .
Preparation of new plastered surfaces of walls and applying two coats of cement base paint of any shade on walls over and including one coat of 3mm thick wall care putty and primer complete all as specified and directed by Engineer-in-Charge.
Two coat of White wash on new palstered surface of ceiling complete all as specified and as directed by Engr-in-Charge
Excavation in post holes (or similar holes) each not exceeding 0.5 cum, in hard/dense soil, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil complete all as specified and directed by Engineer-in-Charge.
Surface excavation n.exc 30cm deep and averaing 15cm deep & getting out in soft /hard soil complete all as specified and directed by Engineer-in-Charge.
PCC 1:3:6 type C2 using 40 mm graded stone aggregate as in foundation filling in post holes complete all as specified and directed by Engineer-in-Charge.
PCC 1:3:6 type C1 using 20 mm graded agg as in surface drain complete all as specified and directed by Engineer-in-Charge.
Steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes conf to IS 1161-1998 grade St-240 complete all as specified and as directed by Engr-in-Charge
Framed work rolled in main raffters purlins where connected with cleat or other connecting plates. complete all as specified and as directed by Engr-in-Charge
Plates square cut or nothced forming holes with out any attachment FE-410W (Gde-E-250 quality-A) complete all as specified and as directed by Engr-in-Charge
Roof trusses (framed) trusses purlins cranes / ganttries , rails & fastering & heavy bracket cleats (including distanence pieces cleats etc) Fe-410W (Gde-E-250 quality-A) complete all as specified and as directed by Engr-in-Charge
Joist, channel, angle, or tee sections,fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) Fe290 (Gde E-165) complete all as specified and as directed by Engr-in-Charge
Framed work rolled in main raffters prulins where connected with cleat or other connecting plates. complete all as specified and as directed by Engr-in-Charge
6 mm thick Plates (plain or chequered) Fe290 (Gde E-165) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment complete all as specified and as directed by Engr-in-Charge
Mild steel work as in Stairs (framed) including stringers, treades, landing, balusters, hand rails etc. Including cleats, brackets, etc. complete all as specified and as directed by Engr-in-Charge
Preparing surfaces of steel and iron surfaces, new or previously untreated surfaces, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed by Engr-in-Charge
Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
Plain cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate as in foundation, filling and mass concrete complete all as specified and as directed by Engr-in-Charge
Preparation new decorated surfaces of walls surfaces and applying two coat of cement base paint over one coat of wall care putty over one coat of cement primer all as specified.
Rotational moulded polyethlene water storage tanks (cylindrical vergical with closed top) hoisted and fixed in position all as specified in SSR Part I,capacity of water tank 500 Ltr complete all as specified and as directed by Engr-in-Charge
Steel water tubing medium grade galvanised with all fitting and fixed complete to wall and ceiling or laid in floors of 20mm bore all as specified.
Steel water tubing medium grade galvanised with all fitting and fixed complete to wall and ceiling or laid in floors of 25mm bore all as specified.
Ball brass valves 20mm , high pressure, with polyethene float & fly-nut complete, screwed for iron pipe or brass ferrule & fixed complete all as specified and as directed by Engr-in-Charge
Gun metal gate valve 25mm bore with iron wheel head complete all as specified and as directed by Engr-in-Charge
Gun metal gate valve 20mm bore with iron wheel head complete all as specified and as directed by Engr-in-Charge
Concrete bed to drain pipes of bore 150mm including packing under,and haunching against the sides of pipes after they are laid and tested in cement concrete 1:4:8 type D-2 using 40mm graded crushed stone aggregate including necessary shuttering and supports, complete all as specified and as directed. Note:- (i) Thickness of bed belew barrel of pipe -10 cm. (ii) Width of bed :- outer dia of pipe plus 30 cm.
Salt glazed stone ware drain pipes of internal diameter 150 mm, grade 'A' quality, laid in trenches and jointed in cement, complete all as specified and as directed .
Precast cement concrete 1:2:4 type B-1 using 20 mm graded crushed stone aggregate as in cover slabs ( for manholes etc). and similar articles with plain faces, set in cement mortar 1:6, complete all as specified and directed by Engr-in-Charge. .
Cutting into exising manholes for connecting new drains (internal dia of pipe n.exc 200 mm), making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section ) in cement concrete 1:2:4 type B-1(using 20mm graded crushed stone aggregate) smooth finished, and reforming benching complete all as specified and as directed.
Cement concrete 1:2:4 type B-1 ( Using 20 mm graded crushed stone aggregate ) as in surface channel or drain etc, complete all as specified and as directed.
Plain Cement concrete 1:2:4 , type B-1 , (using 20mm graded crushed stone aggregate), in lintels upto 1.5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates and similar works including weathering, slightly rouinded for chamfered angles and throating and necessary form work, complete all as specified and as directed by Engr-in -Charge.
Extra for forming fair finished drain or channel upto 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/ stopped ends etc. complete all as specified and as directed .
Plain cement concrete type E-2 (1:5:10) 40mm graded aggregates in foundation complete all as specified and as directed .
Providing plain cement concrete in roof kerbs or mud stop rounded type B-0 (1:2:4) complete all as specified and as directed .
Providing Precast cement concrete 1:2:4 type B-1 Using 20 mm graded stone aggregate as in kerb Stones and in similar works bedded and jointed in CM 1:6 incl necessary exc if necessary.
40 mm th PCC 1:2:4 type B0 using 12.5 mm graded stone agg as in damp proof course to horizontal or vertical surfaces including necessary formwork complete all as specified and as directed by Engr-in-Charge
40 mm thick flooring in PCC 1:2:4 type B1 using 20mm graded stone aggregate surfaces finished even and smooth using extra cement (staircase incl steps). complete all as specified and as directed by Engr-in-Charge
Supply and fixing factory made steel windows (Box type) with glazing bars, dovetailed or welded including hinges, steel handles, steel peg stays etc including one shop coat of red oxide zinc chrome primer, fixed as in repairs, complete all as specified & shown in drawings, complete all as specified & directed by Engr-in-Charge.
Supply and fixing factory made steel windows (Box type) without glazing bars, dovetailed or welded including hinges, steel handles, steel peg stays etc including one shop coat of red oxide zinc chrome primer, fixed as in repairs, complete all as specified & shown in drawings, complete all as specified & directed by Engr-in-Charge.
Pressed steel frames for doors with one or more rebates including necessary supply and fixing lugs, hinges, lock strike plate etc. complete , of frame size 105 x 60 mm, complete all as specified & directed by Engr-in-Charge.
Factory made, 2nd class hard wood rail and style 35 mm thick, plain framed, panelled shutters (two panels) with lock rail and panel of 9 mm BWP commercial ply or 12 mm veneered partical board with commercial veneering on both sides. The size of rail and stile as per IS-1003 (Part-I), kiln seasoned and chemically pressure treated complete all as specified & directed by Engr-in-Charge.
Priming the roof surface with bitumenous primer @ 0.3 litres/Sqm and applying a coat of semi hot blown 85/25 grade bitumen @ 1.2 Kg/Sqm and thereafter supply and laying polymeric membrane, five layered, of weight not less than 3 Kg per Sqm with centre layer core of 90 micron high molecular density polyethylene film and bonded completely to the surface with overlap of 10cm (overlap to be thermo fused by flame) followed by another coat of semi hot blown 85/25 grade bitumen @ 0.7 Kg/Sqm blinded with fine sand in dry condition @ 0.5 Kg/Sqm all as specified and as directed by Engr-in Charge.
Apply two coats of aluminium paint on roof complete all as specifiecd and as directed.
Taking down carefully point wiring copper/aluminium (light, fan, socket, and power) complete (fittings such as switches ceiling roses, pendent regtulators sockets etc to be measured and paid for separately removing materials to store for keeping of safe custody and making good the disturbed surfaces complete all as specified and as directed.
Point wiring with 1.5sqmm PVC insulated unsheathed FRLS cable with multistaranded copper conductor anodised sunken boxs in and incl nonmetallic rigid PVC grade ISI marked PVC surface conduit wiring with vailedC/ML No with all accessories for one light/fan/bell point controlled by one switch with thickness not less than 1.25mm MS terminal boxes concealed on wall with and including 3mm thick laminated backlite sheet including 1.5sqmm PVC insulated unsheathed FRLS cable with multistranded copper conductor continuous earth wire connected to common earth and duly complete all as directed by Engineer-in-charge..
All as per item No 102 above but for one 3/5 pin socket 5 Amp on same board, with cable1.5sqmm size.
All as per item No 102 above but for one 3/5 pin socket 5 Amp on independent board with cable1.5sqmm size.
All as per item No 102 above but for 3 pins socket outlet 15 Amps independent with 2.5 sqmm incl continous earthing with multistandred copper conductor PVC insulated unsheathed size 2.5 Sqmm complete all as specified and directed.
Switch socket combination 2 in 1, 3 Pin, 5 Amp flush type universal complete all as specified and as directed by Engr-in-Charge
Switch socket combination 2 in 1, 3 Pin, 5 and 15 Amp flush type universal complete all as specified and as directed by Engr-in-Charge
Socket outlet 2 in 1, 3 Pin, 5 Amp flush type universal complete all as specified and as directed by Engr-in-Charge
Switch 5 Amps flush type 230 Volts , AC complete.
Eectronic step type regulator of capacity 240 volts flush type complete all as specified and as directed by Engr-in-Charge
Ceiling rose, surface backlite, 65x50mm, three terminals.
Decorative ultra slim square profile LED lighting fixture 05 Watt with extruded polycarbonate, environmental friendly, energy efficient ready to use pack including taking down old US tube light fitting 1x36W and taken in schedule of credit all as specified and as directed by engineer in charge of Make : Havells Cat No : LHEXBTP7IN1W005 or equivallent make of /CG/BAJAJ or equalvent in above specification of any MES approved MAKE .
Submain wiring with 2X6.0 SQMM+1X6.0SQMM Earth Wire single core PVC insulated FRSL sheathed cooper cable connecting to common earth dolly in and including heavy duty PVC Concealed Conduit as per site requirement including taking down old us submain wiringand direction by EIC, all accessories complete all as specified and directed.
Sub main wiring with 2 single core PVC insulated unsheathed stranded copper conductor cable of Size 4 Sqmm with and including PVC CONCEALED CONDUIT "ISI" marked with all fittings and accessories and one single core PVC insulated solid copper conductor cable 4.0 sqmm as contineous earth wire and connected to earth dolly including taking down old us submain wiring all as specified and directed.
Single pole and neutral sheet steel powder coated Distribution board for MCBs fitted with bus bar , Neutral link ,Earth Bar and Din rail suitable for use on 240 V, 50 Hz supply double door SP&N DB system 12 ways complete all as specified and as directed by Engr-in-Charge
C' series SPN MCB 40 to 63Amps 240V ,50Hz,10kA lighting and other domestic loads incl all termnials, fitting complete all as specified and as directed by Engr-in-Charge
C' series SP MCB 06 to 32 Amps 240V ,50Hz,10kA suitable for lighting and other domestic loads incl all termnials, fitting etc complete all as specified and as directed by Engr-in-Charge..
Replacement of single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of 20 Amps 240 volt capacity complete all as directed.
Slim linear LED lighting fixture 20 watt LED batten, with full base of extruded aluminium section acting as a heat sink with closed back, isolated driver, complete making all connection using 1.5 sqmm copper conductor multistrandard PVC insulated 2 core flexible cable with flexible PVC pipe from ceiling rose to fittings complete including taking down old US tube light fitting 1x36W and taken in schedule of credit all as per the direction of Engr-in-Charge. Make -Make model of Havells cat No LHEXCEP7UN1W020 or equilent to CG/ or equalvent in above specification of any MES approved MAKE .
Security (street) light fitting 25 watt, new generation energy saving & environmental friendly long life versatile pressure die cost aluminium IP 66 with acylic, powder coated, pressure die cast aluminium compact high power LED street light with heat resistant toughed glass, corrosion resistant, isolated driver, including provision of GI tubing bracket of suitable size and fixed on wall including clamps, nut, bolts and washer for fixing of security (street) light completet including taking down old US light fitting of any type /size and taken in schedule of creditall as per direction of Engr-in-Charge. Make equivalent in wipro cat No Havells/Wipro or equalvent in above specification of any MES approved MAKE .
XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 2 core in trenches/floor/pole/GI pipe complete including cutting/chasing to any surface and making good to the disturbed surface to match the existing complete all as specified and as directed by Engr-in-Charge
Dry sand cushioning to under ground cables provided with a layer of sand 8 cm deep before laying the cable, 15 cm depth after laying cable & stretching the cable all as specified and directed.
Supply and lay brick class ‘B’ covering as mechanical protection to cable with well burnt complete all as specified and as directed by Engr-in-Charge
GI tubing light grade with all fitting and fixed in wall and floor or fixed to pole of size 40mm dia complete all as specified and as directed by Engr-in-Charge
Material and Labour for earthing complete with GI earth plate electrode 600mmx600mmx6mm thick burried in ground vertically to a depth not less than 2.25meters below ground level with top edge of the earth plate at a depth not lesss than 1.5 meter below Normal ground level, earth plate surrounded 15cm thick layers of common salt and charcoal dust starting from ground below 15 cm of earth plate and up to 15 cm above the same. GI plate connected with galvanised earth lead wire 4.0mm dia by means of GI nuts, bolts and washers of galvanised iron or steel all as shown in electrical plate no.5 connecting to earth test point all as specified or indicated including testing on complition with following:- (a) Test point GI wire 4mm dia . (b) Watering pipe GI light grade 20mm dia from top of the earth electrode up to MS funnel with wire mesh embeded in floor of PCC earth pit. (GI Funnel should properly tightned on GI watering pipe and embeded in PCC floor of earth pit with open top suitable for watering of earth pits) (c) PCC earth pit 30x30x30cm constructed in PCC 1:2:4 type B1 exposed surfaces smoothly finished with 15mm thick cement mortar 1:6 plaster including RCC pit cover 25mm thick with 2 Nos MS handles of 12mm dia suitable for carrying of pit cover. (d) Angle iron frame made of 40x40x4 mm angle iron for 30x30 mm PCC pit for holding the pit cover.
Earth continuity conductor or main earhing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron or steel wire complete all as specified and as directed by Engr-in-Charge
Taking down fan, ceiling cable end, dismantling blades and kept in safe custody for refixing on same location all as specified and directed by engineer in charge.
M&L for repair of ceiling fan/exhaust fan 1200mm/300mm sweep of any make obtained from above item, oiling, greasing cleaning slot, over hauling & replacement of defective nut bolts washer etc including painting. If as per site requirement fan will be found burnt rewinding will be provide by the contractor as per unit quoted rate all as specified and directed by Engr-in-charge.
Hanging /fixing only ceiling fan/Exhuast fan and connecting up including provision of cable from ceiling rose or connector to fan obtained from item no 32 complete all as specified and as directed by Engr-in-Charge
In replacement E-Lite LED Curve lighting fixture for mirror 12 watt LED batten,T5 with full base of extruded Aluminium body environmental friendly, energy efficient ready to use pack with isolated driver, complete making all connection using 1.5 sqmm copper conductor multistrandard PVC insulated 2 core flexible cable with flexible PVC pipe from ceiling rose to fittings complete including taking down old unserviceable tube light fitting 1x 18 watt from the site reuse to measured seprately or disposal by credit all as per the direction of Engr-in-Charge. Make -Havells as per ordering code LHEXBYPNIN1W010 / wipro cat No D531065/ or equalvent in above specification of any MES approved MAKE .
Supply and install geyser 25 Ltrs capacity Vertical type BEE5 star rating suitable to operate in Single phase AC supply,230 volts 50 Hz including suitable size heavy duty Pvc connection hot & cold and grouting fashner with suitable size on the wall as per site requirment complete all as specified and as directed by Engr-in-Charge
Supply and fixing Heavy duty turbo force single phase Exhaust fans 1400 rpm of 300mm complete with louver heaving aluminium / sheet metal flap with thickness not less than 1.00mm and mounting assembly including fixing exhuast fan with grouting of nut & bolts complete all as specified and as directed by Engr-in-Charge
s l sharma and sons
KUMAR CONSTRUCTION CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .