| 1 | L1₹5.4 CrAccepted-AOC | ₹5.4 Cr | L1 | Accepted-AOC L1 accepted bidder |
| 2 | L2₹5.7 Cr+₹25.6 L (4.72%)Rejected-Finance | ₹5.7 Cr+₹25.6 L (4.72%) | L2 | Rejected-Finance Not being L1 |
| 3 | Rejected-Technical X 125 NEW ROSHANPURA SHAHEED RAJESH GILL MARG NAJAFGARH SOUTH WEST DELHI DELHI 110043 UDYAM DL 10 0019190 06AADCJ2143B1Z8 B 07AADCJ2143B1Z6 R MSME STATUS AS VERIFIED | WEST DELHI | DELHI | 110043 | - | - | Rejected-Technical Not eligible as per NIT |
| 4 | Rejected-Technical 3 81 M S BUILDING CHEMBUR COLONY CHEMBUR CAMP MUMBAI MAHARASHTRA 400074 | MUMBAI SUBURBAN | MAHARASHTRA | 400074 | - | - | Rejected-Technical Not eligible as per NIT |
| 5 | Rejected-Technical | - | - | Rejected-Technical Not eligible as per NIT |
Tender Value
₹6.4 Cr
EMD Value
₹7.9 L
Closing Date
6 Mar 2024, 11:00 amClosed
General Manager( Civil)/ Welfare and Services, CCL
Office of General Manager (Civil)/Welfare and Services , CCL, Darbhanga House, Ranchi- 834029
Planning, design, engineering, supply, installation, testing and commissioning of VRF (variable refrigerant flow) system in Alaknanda building, Damodar building and Sales an Marketing dept. at DHC, CCL (refer NIT)
2024_CCL_300226_1
CCL/WnS/Tender/23-24/6831-41 Dt. 01.02.2024
Turnkey
Electrical and Maintenance Works
Item Rate
180 days
Darbhanga House Complex, CCL, Ranchi
As per NIT
9 documents required · 9 mandatory
₹7.9 L
Office of GM(C)/Welfare and Services , CCL, Ranchi
13 Jun 2024
5 Feb 2024
7 Mar 2024
6 Feb 2024
6 Mar 2024
13 Feb 2024
6 Feb 2024 - 29 Feb 2024
12 Feb 2024
Amount
A. OUTDOOR UNIT
Supplying,installation,Testing & Commissioning, modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling and heating, having all hermetically sealed inverter type Scroll Compressor(s) ,minimum two compressors for above 14HP modules ,microprocessor based Controller, top discharge type condensing unit(s), with R410A Refrigerant ,vibration isolators ,with suitable foundation etc. complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping.The unit shall be suitable to work on 400V+/-10%, 3Phase, 50 Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5 . (Minimum capacity for all three places combined together should be 630 HP ) For details please refer Vol- II
B. INDOOR UNIT- CASSETTE UNIT
Supply,installation,testing and commissioning of following minimum capacity 4way/1way flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable mediapre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drainpump, grill, necessary supports, vibration isolation ,cordless remote control etc.,suitable for operationon single phase 230V±10%, 50Hz AC supply, complete, as required. The unit shall have automatic force shutdown provision incase of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree CDB and 19 Degree CWB temperature. (Minimum capacity of total cassette unit combined together for all three places should be 505 Tr (4 way-227 Tr and 1 way-278 Tr) Individual capacity of cassette unit should vary from 0.8 Tr to 4.0 Tr and should be 1way/4way as per site requirement) For details please refer Vol - II
C. Installation and commissioning
(a) Refrigerant Piping:- Supply,Installation,testing and commissioning including vaccumiazation and Nitrogen testing of different nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/ brazing including accessories, insulated with XPLE Class-O tubular insulation/ with Class-O closed cellelastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required with Y-joints for indoor and outdoor units (Minimum pipe size 6.4 mm OD and maximum pipe size 41.27 mm OD) (b) Chemical Earthing with earthpit and connections as required (c) Drain Piping with uPVC as required (d) Communication cabling between indoor and outdoor as required (e) Suitable power supply arrangement to indoor and outdoor as per requirement (f) Fabrication of structure for outdoor base (g) Repairing of false ceiling as per requirement (h) Separate main power supply from substation to respective building for HVAC system as required (i) Any other item required to complete the work. (j) Maintenance of VRF system (all inclusive) including supply of required manpower, spares and consumables during defect liability period of 5(five) years after commissioning of plant as per tender document. etc For details please refer Vol-II
Total impact of GST for the purpose of CTC
Universal associate
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .