| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.1 LAccepted-AOC | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹39.8 L+₹3.2 L (8.69%)Rejected-Finance | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹39.8 L+₹3.2 L (8.82%)Rejected-Finance | L3 | Rejected-Finance NOT LOWEST | |
| 4 | L4₹42.6 L+₹6.0 L (16.4%)Rejected-Finance | L4 | Rejected-Finance NOT LOWEST |
Tender Value
₹44.2 L
EMD Value
₹89,000
Closing Date
18 Nov 2022, 6:00 pmClosed
Garrison Engineer Abohar
Garrison Engineer Abohar Pin 152116
Special Repair to Bldg No P-164/01 to 12 Military Station Fazilka
2022_MES_559353_1
GE ABH-46/22-23
Open Tender
Civil Works
Item Rate
60 days
Fazilka Mil Stn
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Garrison Engineer Abohar
₹89,000
Yes
21 Jan 2023
22 Oct 2022
21 Nov 2022
22 Oct 2022
18 Nov 2022
5 Nov 2022
Amount
SCHEDULE 'A' SECTION I (B&R Portion)
Taking down chowkats or frame with shutters(without taking off shutters from the frame not exceeding 1.50 sqm each & removing to store all as specified and directed by Engineer - in-Charge.
Taking down chowkats with shutters(without taking off shutters from the frame exceeding 1.50 sqm each but not exceeding 4 sqm) removing to store all as specified and directed by Engineer - in-Charge.
Taking down shutter of any description exc 1 sqm and n exc 2.00 sqm each and removing to store yard all as specified and directed by Engineer-in-Charge.
Refixing of shutter in other opening of any description exc 1 sqm and n exc 2.00 sqm each all as specified and directed by Engineer-in-Charge.
S&F solid PVC door frame of size 50mm X 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tubes including painting of edges to match with sheet,all as specified & shown in relevant drawing of item No. 8095 in MES SSR -2020 ( Part-II ),fixed in opening complete all as specified and directed by Engineer in Charge.
Supply and fixing factory made solid core PVC door shutter 30mm thick (stiles) consisting of frame made out of MS tubes of 19mm gauge thickness and size of 19mmx19mm for stiles and for top and bottom rails 15mmx15mm. MS frame shall have a coat of red oxide primer of approved make and shall be covered with heat moulded plain colour PVC sheet, 'C' channel of size 30x50mm forming stiles and 5mm thick wide PVC sheet strip of 20mm width stuck inside with solvent cement for stiles, and plain colour PVC sheets for top rail, lock rail & bottom rail on either side and 10mm (5x2mm) thick, 20mm thick PVC sheet to be fitted in MS frame welded/ sealed to the stiles and rails with 30mm wide x 5mm thick PVC sheet beading on either side and joined together with solvent cement adhesive and an additional 5mm thick PVC strips of 20mm width is to be stuck on interior side of C channel using PVC solvent adhesive as per manufacturer's instructions, door to be fixed to frame with and including 3 Nos MS powder coated butt hinges of size 100mm long x 25mm wide and 2mm thick and fixing with 32mm long steel screws drilled suitable to pass through both the walls of the MS tube complete all as specified in SSR-2009 (Part-I, specifications) & shown in relevant drawing of item No. 8080 in SSR-2010 (Part-II, rates). The width of stiles & rails will be in proportion to the width of the door shutter as specified in SSR-2010 (Part-II). complete all as specified and as directed by Engineer-in-Charge.
S&F Aluminium handle cast type anodized 125 mm long all as specified and directed by Engineer-in-Charge.
S&F Aluminium anodized barrel tower bolt of extended section and fixed 150 mm long all as specified and directed by Engineer-in-Charge.
S&F 100 mm long butt hinges extruded almiunium alloy with galvanised mild steel hinges pin, anodised and fixed all as specified and directed by Engineer-in-Charge.
S & F pressed steel door frames with one or more rebates including necessary fixing lungs hinges lock strike plate etc complete all as specified size of frame 105 x 60mm all as specified and directed by Engineer - in - Charge .
S & F pressed steel door frames with one or more rebates including necessary fixing lungs hinges lock strike plate etc complete all as specified size of frame 125 x 60mm all as specified and directed by Engineer - in - Charge .
M&L Cement concrete 1:2:4 type B–1 filling of pressed steel frame and hold fast blocks etc all as specified and directed by Engineer - in - Charge.
S & F 35mm thick 2nd class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc.; size of members of shutters as specified in SSR Part – I, Section – 8, clause 8.20 (a) ; supplied and fitted to chowkats all as specified.
S & F flush shutter 35mm thick solid core construction with block board core and plywood face panels commercial type on both sides with lipping / frame to match all as specified and directed by Engineer - in - Charge.
S&F Solid PVC frame (Single Rebated) of size 60mm x 30mm made out of solid PVC foam with homogenous fine cellular structure having smooth outer integral skin with suitable metal stiffner and fixed with 100 x 8 sheet metal CSK screws complete all as specified and as shown on drawing (Note :- Door frame shall be water proof, termite proof, elegant and should have excellent screws holding strength to fix hinges and hold doors properly for a long life)
Material and labour for providing kitchen cabinet and cubboard in required sizes at site made out of 18mm thick PVC sheet (prelam) having one side decorative laminated sheet (for shutter, sides of cabinet, partition and shelves etc). All the edges of shutter and front exposed edge of partition/shelves shall be covered with 2mm thick edge bonding tape as per manufacturer. Including all required fixing material such as SS brackets, screws, adhesive etc., including taking out old any type cabinet complete all as specified and as directed by Engineer-in-charge. Note :- (i) The area of each sheet (shutter, sides of cabinet, partition and shelves) shall be measured in sqm for payment. (ii) Magnetic catcher, handles, continuous Piano hinges and PVC frame (where required) shall be measured and paid separately under appropriate item of BOQ. (iii) Any other material required for making/fixing/hanging of cabinet shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account.
S&F Stainless steel tower bolt 150mm long fency type heavy duty all as specified and directed by Engineer - in - Charge.
S&F stainless steel handles of size 150mm fency type heavy duty all as specified and directed by Engineer - in - Charge.
S&F 250mm Stainless steel sliding door bolts, plate type, with bright bolt not less than 12mm dia and including minimum of 6 bolts and nuts, four on bolt plate and two on staple complete all as specified & directed.
S & F Magnet ball catcher for cupboard shutter, complete all as specified and directed by Engineer - in-Charge.
S & F continous (Piano)type hinges mild steel bright finish or lectro galvanised with wide of flaps 30mm complete all as spd and directed.
S&F 125 mm size hasp and staple,aluminium anodished,including bolt to hinge plate and fixed with screws,complete all as directed.
M&L preparing surface of wood and wood based surface new on any description not other wise described over 10cm with or grith and applying two coat of synthetic enamel paint over a coat of pink primer all as specified and directed by Engineer - in - Charge.
M&L applying two coat of synthetic enamel paint on old decorated wooden surfaces exc 10 cm width or girth, including preparation of surfaces, complete all as specified and directed.
S&F in repair MS 300mm ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed by Engineer-in-Charge.
M&L for applying one coat of synthetic enamel paint on old decorated steel surfaces exc 10 cm width or girth including preparation of surfaces , complete all as specified and directed.
M&L applying two coats of synthetic enamel paint over a coat of red oxide 0r zinc chromate primer including preparation of new steel or iron surfaces exc 10 cm width or girth, complete all as specified and directed.
S&F galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks or galvanesed wire stapels complete all as specifed and directed.
Demolition of cement concrete ( un re-inforced) of any description in roofs, floors(other than ground floors), beams, staircases, landing, chajjas and similar suspended work all as specified.
Dismantling brick terracing tiles single layer from roof laid and pointed in cement mortar and removing/disposal off from the site complete all as specified and as directed by Engineer-in-charge.
Demolition/taking out of mud from roofs, any thickness, including removing / cutting uprooting grass,vegetations and roots of small plants etc on roof and surrounding/parapit wall etc, including removing rubbish material from building and thrown in low lying empty area (as per direcction of AGE) at any distance upto 500 metres from the site complete all as specified and as directed by Engineer-in- Charge
Material and labour for 15mm thick rendering /screed in cement mortar (1:3) on roof slab including mixing of liquid WPC in mortar @ as per manufacturer instruction per bag of cement of 50kg and finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge. (Note :- WPC shall be measured & paid separately as Supply only under relevant item of BOQ).
Material and labour for cleaning of top roof surface by wire brushing, removing all dust, loose particle of concrete and washing with water and apply cement concrete flooring type B0 1:2:4 using 12.5 mm graded aggregate on roof slab all as specified and directed by Engineer-in-Charge.
Material and labour for Preparing surface of old roof slab and cleaned of all foreign materials such as fungus, moss, dust etc, by wire brushing dusting, sprinkling water on the surface and ensure water does not stand anywhere. If it is so, the roof surface shall be leveled than surface shall be painted with one coat of cold applied bituminous primer @ 0.40 ltr per sqm, applied over primed surface APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) laid on primed surface by forced application, torching with overlaps as recommended by the manufacturer complete all as specified and as directed by Engineer-in-charge.
Material and labour for lime concrete terracing using brick aggregate and surkhi as specified in clause 11.11 and laying as specified in clause 11.27 of MES Sch Part-I (2009) minimum thickness at edge 40mm and increasing uniformly towards ridges to obtain a chain slope 1:40, the top shall be trowelled with the addition of jaggery solution and finished smooth complete all as specified and as directed by Engineer-in-charge.
Material and labour for 40mm thick brick tiles laid/bedded on screed bed 15mm thick in cement mortar (1:6), on existing lime concrete surfaces of roof, joints grouted flush in cement mortar (1:3) mixed with liquid WPC @ as per manufacturer instruction per bag of cement of 50kg and including flush pointing as work proceed with same material complete all as specified in clause 11.27.3 of MES Sch Part-I (2009) complete all as specified and as directed by Engineer-in-Charge. (Note :- Water proofing compound shall be measured & paid separately as Supply only)
Material and labour for 40mm thick brick tiles (old serviceable tiles obtained from demolition/dismantled item shall be reused) laid/bedded on screed bed 15mm thick in cement mortar (1:6), on existing lime concrete surfaces of roof, joints grouted flush in cement mortar (1:3) mixed with liquid WPC @ as per manufacturer instruction per bag of cement of 50kg and including flush pointing as work proceed with same material complete all as specified in clause 11.27.3 of MES Sch Part-I (2009) complete all as specified and as directed by Engineer-in-Charge. (Note :-Water proofing compound shall be measured & paid separately as Supply only)
M & L PCC 1:2:4, type B-1 , using 20mm graded stone aggregate as in kerbs or mud stops, rounded or chamfered on edges and similar work all as specified and as directed.
M&L machine cut kota stone slab flooring 16-18mm thick in single piece over cement screed base laid and jointed with grey cement mixed with pigment to match the shade of the slab including rubbing and polishing complete inculding screed bed or bedding layer of mortar 15 mm thick CM (1:6)all as directed by Engineer-in-Charge.
M&L for kota stone slab flooring 16-18mm thick in single piece in riser of steps,skirting,dado and pillar laid and jointed with grey cement mixed with pgment to match the shade of the slab including rubbing and polishing complete inculding screed bed or bedding layer of mortar 15 mm thick CM (1:6)all as directed by Engineer-in-Charge.
M&L 16-18mm thick granite (of any type ) work (table rubbed and polished ) in cooking platform and like in cm (1:4) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shed of granite.
Demolation of ashlar facings, dressed stone work, stone slabs or tiles from paving and precast concrete blocks and articles all as specified.& directed by Engineer -in-charge..
Taking down cement or cement lime plaster from brick walls etc including raking out joints, hacking for key scrubbing down with water etc.
M & L 10mm thick rendering in Cement Mortar 1:3 on fair faces of brick work or concrete surfaces of ceiling finished even and smooth without using extra cement complete all as specified and directed by Engineer - in - Charge .
M & L rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1:6 finished even & smooth without using extra cement all as specified and directed by Engineer - in - Charge .
M&L Washed coloured stone grit plaster on exterior walls in two layers, under layer 12mm cement plaster 1:4 (1 cement: 4 coarse sand ) furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 3 Kg of cement per square metre, top layer 15mm cement plaster 1:1/2:2 (1 cement: 1/2 coarse sand : 2 pigmented stone chipping 10mm nominal size) in panels with groove all around as per approved pattern including scrubbing and washing, the top layer with brushes and water to expose the stone chippings .complete all as specified (Payment for providing grooves shall be made separately).
Forming groove of uniform size 15mm wide and 15mm deep in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer including removal of wooden attens, repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge
M & L applying three coat of white wash on newly plastered or unplastered ceiling surfaces including preperation of surfaces, complete all as specified.
M & L Preparation of newly plastered surfaces by applying two coats of interior grade wall putty and making it smooth with sand paper by mechanical method i.e. with hand electric grinder then applying two coats of oil bound distemper over one coat of cement primer including all as specified by mechanical method i.e. spray gun all as specified and directed by Engineer-in-charge.
M & L Preparation of Old plastered surfaces by removing old treatment and applying two coats of interior grade wall putty and making it smooth with sand paper by mechanical method i.e. with hand electric grinder then applying two coats of oil bound distemper over one coat of cement primer including all as specified by mechanical method i.e. spray gun all as specified and directed by Engineer-in-charge.
M & L for complete removal of existing treatment and applying two coats of white wash on old decorated plastered or unplastered surfaces of ceiling including preparation of surfaces complete all as specified and directed by Engineer - in - Charge .
M & L for complete removal of existing treatment and applying two coats of white wash on old decorated plastered or unplastered surfaces of walls including preparation of surfaces complete all as specified and directed by Engineer - in - Charge .
M & L applying three coat of white wash on newly plastered or unplastered wall surface including preparation of surfaces, complete all as specified.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), remving serviceable tiles to stores and and rubbish off the permises.
M & L for glazed ceramic coloured tiles 7mm thick 300 x 450mm size in vertical surface set and jointed in neat cement slurry and pointed in white cement paste pigmented to the shade over and including 10mm thick cement sand plaster (1:3) complete all as specified and directed by Engineer - in - Charge.
M&L Non skid ceramic coloured /printed tiles 400*400* 7 to 8 mm thick( square /rectangular) and shall be jointed in neat cement slurry and pointed in paste pigmented to tile shade over and incl 15 mm th screed bed in CM 1:6 complete all as specified and directed by Engr in Charge.
M & L 25 mm thick Cement Concrete 1:2:4 type B–0 using 12.5mm graded stone aggregates flooring finished even and rough to receive topping layer all as specified and directed by Engineer - in – Charge .
M & L for 75mm thick cement concrete type D-2 (1:4:8) using 40mm graded stone aggregate as in sub floors, sub bases etc all as specified and directed by Engineer - in - Charge.
S&F machine pressed precast concrete interlocking paver block with grey cement & no pigment, any shape and size confirming to IS 15658-2006 of 80mm thick M-40 grade including and over 25mm thick sand cushion.
S&F in repairs stainless steel sink overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, complete all as directed.
S & F in repairs stainless steel plate rack of size 900x775x250mm of 1mm thick stainless steel of 1st Quality all as specified and directed by Engineer-in-Charge.
S&F 25 mm dia drapery curtain road with decoative end knobs complete with brackate and fixed to walls complete all as specified and directed by Engineer-in-Charge.
Dismantling water tanks and removing to store of 500 ltr capacity
S&F rotational moulded polythene water storage tank (Cylindrical vertical withclosed top) hoisted and fixed in position of 500 ltrs capacity fixed with PVC tank nipples,complete all as specified in SSR Part I.
Ditto above items 66 except water tank 500 litres.
M&L ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball with minimum weight 210 gm screwed for 20mm bore iron pipe supplied and fixed complete all as specified and as directed by Engineer-in-charge.
M&L in repairs ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball with minimum weight 210 gm screwed for 20mm bore iron pipe supplied and fixed complete all as specified and as directed by Engineer-in-charge.
S&F gun metal globe or gate valve with iron wheel screwed both ends for iron pipe of 20 mm dia all as directed.
Material and labour for water proofing treatment to sunken slab and adjoining vertical surfaces as per any of the following method complete all as directed by Engineer-in-charge/GE. :- Method 1 (A) Supplying and applying two component elastomeric acrylic polymer modified cementitious waterproofing coating, Smart Care Damp proof 2K, having 100% elongation as per ASTM D412, resisting 5 bars hydrostatic pressure as per DIN 1048, reduction to rapid chloride shall be 70 as per DIN 1048, crack bridging upto 1.2mm as per ASTM 4548.5 Clean all working surface & made free from dirt, grease laitance etc. After inspection for all working area rough surface, cracks & construction joint are treated by polymer modified mortar of 1:1:4 (1 Cement : 1Polymer : 4 Sand). Making Gola of size 75x75mm at junction of vertical & horizontal with the polymer modified mortar of 1:1:4 (1 Cement : 1 Polymer : 4 Sand). The coating shall be terminated at 300mm on vertical walls. The mixing ratio of the coating shall be 2 parts of powder & 1 part of liquid without any water addition in the mixing and shall have consumption of 1.5kg/sqm per coats, etc, complete as per manufactures specifications.
B) Bore Packing : All the borehole gaps between concrete surface and pvc pipe of various dia upto the neck level shall be filled with non-shrink free flow grout – Smart Care GP Grout or approved equivalent having dual shrinkage compensation property. Before the bore packing, surface of the pvc pie and concrete surface will be made rough and sand will be sprinkled with polymer bonding agent. (C) Apply12-15mm plaster on slab and vertical surface admixed with Smart Care Vitalia Neo @200ml per bag of cement.
Method 2 (A) Supplying and applying two component cementitious & acrylic flexible water proofing & protective coating, two coats with 1mm DFT, having Hydrostatic (positive) water pressure resistance (DIN 1048) is 7. Abrasion resistance, cm/km is 0.09 of Dr Fixit Pidifin 2k @ 1.5kg/sqm with a paint brush over existing roof surface. The Polyester reinforced coated net of 45g/sqm, 2.5mmx2.5mm is laying on the surface immediately on the first coat of two component modified polymer Dr Fixit pidifin 2k or equivalent. After removal of all lose materials like dust etc. with wire brush coir brushes from roof surface to get absolutely cleaned surface free of foreign contaminant filling of crack and patches with polymer based repair mortar/micro concrete, after the repairing work making the gola on surrounding wall’s junction and seal the vertical walls up to 300mm. In case of core cutting on the surface, the joint is seal with non-shrink grout. (B) Apply12-15mm water proof plaster on slab and vertical surface admixed with Dr Fixit pidiproof LW+ @200ml per bag of cement before treatment.
Note : (i) Work shall be executed through specialized agency (ii) The treatment shall be carried outas per the manufactures instructions and as directed by the Engineer in charge. The name of firmshall be got approved from CWE before carrying out the work. (ii) The Plan area of floor shall be considered for payment. (iii) PCC filling under sunken area will be measured & paid separately. Make : Method 1 (Asian paint)/ Method 2 (Dr fixit) or Techno commercial equivalent in Fosroc/Sika/STP
M & L PCC (1:5:10) using 40mm graded burnt bricks aggregate as in foundation filling & mass concrete or as in shunken floor complete all as specified.
supply only liquid water proofing compound complete all as specified and directed by Engineer-in-Charge.
Dismantling of CI pips or reinforced concrete pipes 100 mm dia fixed to wall etc complete all as specified and directed.
Dismantling of CI pips or reinforced concrete pipes 75 mm dia fixed to wall etc complete all as specified and directed.
Supply & fixing 110mm bore PVC (SWR) pipes single socketed (pressure rating not less than 6kg/sqcm) in any length with rubber ring joints for drain or rain water fixed along walls with and including PVC clamps, complete all as specified and as directed by Engineer-in- charge.
S&F 110mm PVC (SWR) pipes single socketed(pressure rating not less than 6kg/sqcm) in any length with rubber ring joints laid in trenches or in floors, complete all as specified and directed.
Supply & fixing 75mm bore PVC (SWR) pipes single socketed (pressure rating not less than 6kg/sqcm) in any length with rubber ring joints for drain or rain water fixed along walls with and including PVC clamps, complete all as specified and as directed by Engineer-in- charge.
S&F 75mm PVC (SWR) pipes single socketed(pressure rating not less than 6kg/sqcm) in any length with rubber ring joints laid in trenches or in floors, complete all as specified and directed.
Supply & fixing PVC (SWR) bends (any radius) suitable for 110mm bore pipe complete all as specified and as directed by Engineer-in- charge.
Supply & fixing PVC (SWR) bends (any radius) suitable for 75mm bore pipe complete all as specified and as directed by Engineer-in- charge.
Supply & fixing PVC (SWR) floor trap, plain with grating, suitable for 100/75mm bore pipe including jointing with solvent cement complete all as specified and as directed by Engineer-in- charge.
Supply and fixing PVC (SWR) reducer 110/75 complete all as specified and as directed by Engineer-in-charge.
Supply & fixing PVC (SWR) vent cowl suitable for 75mm bore PVC pipe complete all as specifiedand as directed by Engineer-in- charge.
Supply & fixing PVC (SWR) of size 110 mm sanitary connection socket to fit out let of WC complete all as specified and directed by Engineer-in-Charge.
Supply & fixing 110mm bore PVC (SWR) junction single (single T) equal or unequal fixed with solvent cement, with access door complete all as specified and as directed by Engineer-in- charge.
Supply & fixing 75mm bore PVC (SWR) junction single (single T) equal or unequal fixed with solvent cement, with access door complete all as specified and as directed by Engineer-in- charge.
S&F 110mm PVC(SWR) couplers complete all as specified and directed.
S&F 75mm PVC(SWR) couplers complete all as specified and directed.
S&F 110mm PVC(SWR) branch piece, single (single Y) equal or unequal fixed with solvent cement, with oval access door, complete all as specified and directed.
Taking up or down steel tubing of 15 mm bore and connections, including cleaning for re-fixing or removal to store
Taking up or down steel tubing of 20 mm bore and connections, including cleaning for re-fixing or removal to store
Refixing 20 mm old steel tubing and connections in new or old possition ( wall ceiling floors, etc.)
S&F Chlorinated PVC (CPVC) pipes 20 mm outer dia, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.0 m spacing . this includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete all as specified and directed. Make : Supreme/Vectus or equivalent
Supply & fixing mild steel tubes of size 20 mm bore (medium grade) galvanised with all fittingsand fixed complete to wall all as specified.
Supply & fixing mild steel tubes of size 40 mm bore (medium grade) galvanised with all fittings and fixed complete to wall or floors all as specified.
S&F in repairs vitreous china wash down water closet pan padestel pattern white including connection pipe to union of flushing cistern, inlet and overflow pipes,connecting only to flushing cistern anti-syphonage pipe with PVC flush pipe of 32mm dia including Jet spray and plastic seat cover with mild steel chromoum plated hinging and 'P' or 'S' trap device complete all as specified and directed by Engineer-in-Charge.
S & F in repairs PVC 10 ltrs syphonic action type flushing cistern, low level with inlet, ball valve, float and handle including brackets, flush pipe of PVC 32mm bore and connection to WC pan complete all as specified .
S&F in repair vitreous china,white wash hand basin ,pedestal type, flat back size 550x400mm complete all as specified and directed by Engineer-in-Charge.
S&F in repair bib taps long body, 15mm bore dia, fancy type, cast copper alloy chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe all as specified .
S & F in repairs 15mm bore CP Angle cock one way chromium plated, high pressure, with crutch or butterfly handle, screwed both ends of iron pipe or for union and fixed all as specified .
S&F in repairs 15mm stop valves fancy type, chromium plated with long shank and cup (concealed type) ,cast copper alloy, screwed down, high pre-ssure, with crutch or but-terfly handle, screwed both ends for iron pipe or for unions and fixed.
S & F in repair brass chromium plated central hole basin mixer with regular spout , popup waste system and 450mm long braided hoses with connection and nuts complete all as specified and directed by Engr-in-charge.
S&F sink mixer with swinging spout (wall mounted model) chromium plated brass with connection and nut complete all as specified and directed by Engineer-in-Charge.
S & F in repairs brass chromium plated wall mixer with for mixing hot and cold water screwed down for iron pipe and fixed as directed by Engr-in-charge : Make : ESS ESS/Prayag/Jaquar or equivalent.
S & F in repairs for brass chromium plated shower rose 150 x 150 mm size with swivel joint including fixing to 15 mm dia steel pipe or union.
S & F soap dish brass chromium plated, fixed to plugs with brass chromium plated screws complete all as specified and directed by Engineer - in - Charge
S & F brass chromium plated tubular towel rail 20mm dia “D” type 60 cm long between flanges incldg brackets complete all as specified and directed by Engineer - in - Charge .
S&F in repair CP grating suitable for 75/100 mm bore floor trap and fixed with white cement.
S&F in repair PVC connection both side brass unions internal for size 15mm dia and 600mm long all as specified and directed by Engineer-in-Charge.
M & L RCC 1:1½:3, (nominal mix), Type A-1, using 20mm graded aggregates as in chajjas, fins, fascias,shelves , louvers, parapets and railing etc and the like including necessary formworks all as specified and directed by Engineer - in - Charge.
S&F TMT bars 10mm dia and over, cut to length, bent to shape required,including binding with mild steel wire (annealed) not less than 0.9mm dia.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for.
Demolition of brick work or stone masonry built in cement mortar including all quoins, pillars, arches etc. but excluding ashlar facings, dressed stone work and precast concrete articles, complete all as specified and as directed.
M&L Brick work with old size burnt fly ash bricks, straight or curved on plan exceeding 6 mtr mean radius built in CM 1:6 all as specified and directed by Engineer - in - Charge .
M&L 50mm thick PCC 1:3:6 type C2 using 40 mm graded stone aggregate as in plinth protection, surface finished even smooth without using extra cement.
S&F Alum door stopper of any description all as specified and directed by Engineer-in-Charge.
S & F in repair powder coated aluminum sliding window three track with frame & two glass shutter using 4 mm thick glass tinted modi guard and one shutter with stainless steel wire gauge wire cloth 0.31 mm nominal dia of wire and width of aperture 1.61 mm using aluminum powder coated section aluminum cleat , PVC track, bearing, handle lock rubber beading etc complete fittings as approved. Note :- Size of aluminum section shall be under – (i) three track top and vertical – jindal main 2010. Section No 20621 or equivalent as approved by GE. (ii) Three track bottom – Jindal main – 2010 section 20620 or equivalent as approved by GE. (iii) Shutter Vertical Section - Jindal main – 2010 section 20604 or equivalent as approved by GE. (iv) Shutter top and bottom - Jindal main – 2010 section 20604 or equivalent as approved by GE. (v) Shutter vertical middle ( interlock) - Jindal main – 2010 section 20605 or equivalent as approved by GE.
S&F powder coated anodized aluminum frame for doors, windows , ventilators with one of more rebates including joining cleat for fixing etc. completed all as specified
S&F powder coated aluminum Window/Ventilators shutter side hung type without sash, aluminum section weighing glazed clips, rubber packing anodized aluminum fittings such as peg stays 150 mm long (1 nos) hinges type B-21 100 mm long (2 Nos) suitable handle (1 Nos) complete all as specified.
S&F aluminum anodized grill diamond shape 100mm x 100mm aperture of 6 mm dia round bars including necessary joining cleats, clips anodised complete all as specified.
S&F fibre sheet 2mm thick reinforced translucent plain sheeting with drilling punching corrougation fixed with coach screw and washer etc in angle wall and other necessary item, complete all as specified
S&F Structural steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes grade St-240 complete all as specified and as shown on drawing.
Shortcreting 25MM thick in RCC columns, beams and slabs etc in layers with approved design mix(minimum cement content of 350 Kg/Cum on M-25) concrete having the specified minimum characteristic compressive strength (with ordinary protland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria) including the cost of certering and shuttering at edges and corners etc as directed by Engineer-in-Charge including Chipping of unsound/weak concrete material 25mm average thickness from slabs, beams, columns etc with manual chisel and/or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes and thoroughly washing with water and allowing it to dry etc. including removal of rust by applying approved rust removal chemical & the coating with Dr Fixit epoxy zinc primer@6 sqm/ltr at DFT of 100 microns as per specifications and disposal of debries for all lead and lifts all complete as per direction of Engineer-in-Charge. Note : After completion of shorcreting the splash of cement on wall to be cleaned completely.
S & F Hard drawn steel wire fabric not exc 4Kg/Sqm cut to lengths, bent to shape required and typing with and including mild steel wire (annealed) not less than 0.9mm in dia supplied and fixed in reinforcement all as specified & directed by Engineering-in-Charge.
SCHEDULE 'A' SECTION II (E&M Portion)
Taking down carefully existing aluminium/Copper point wiring light, fan socket or power bell complete with fitting such as sockets, ceiling roses, pendants batten holders regulators socket, call bells & making good to the disturbed surfaces of walls, matching the colour with existing Surface all as spd and directed by Engr-in-Charge. Note: Rate for making good shall be deemed to be included in above item rate.
Taking down unserviceable main switches and MCB distribution boards single phase complete all as spd
M & L for point wiring complete with 1.5 Sqmm (Nominal area) PVC insulated multustranded fire retardant (low smoke unsheathed and multicore copper conductor cable with colour code ISI marked and including PVC concealed conduict ISI marked and conduit fittings for one light point/fan point/exhaust fan controlled by one switch including PVC insulated 1.5 Sqmm single core copper earth wire to common earth and connecting to earth dolly and including suitable MS sunken box of suitable size and covered with & including 3 mm thick bakelite, laminated hylem sheet top cover etc complete all as specified (Cost of MS sunken box and bakelite sheet included in the rate).
All as per Srl item No. 1 here-in-before but one three pin socket outlet 5 Amps on the independent board complete all as specified.
All as per Srl item No. 1 here-in-before but one three pin socket outlet 5 Amps on the same board complete all as specified.
All as per Srl item No.1 here in before but with 1.5 Sqmm (nominal area) PVC insulated multistranded copper conductor cable unsheathed ISI marked controlled by two way switches complete all as specified.
M&L for point wiring complete with 2.5 Sqmm (Nominal area) PVC insulated multistranded fire retardant low smoke unsheated and stranded copper conductor cable ISI marked in and including PVC concealed conduit medium quality and conduit fitting for 3 pin 15 amp multicore switch socket combination including PVC insulated 2.5 Sqmm single core copper earth wire to common earth and connected to earth dolly and including suitable MS sunken box of suitable size and covered with & including 3 mm thick bakelite, laminated hylem sheet top cover etc complete all as specified.
S&F switch Piano type single pole one way 5 Amp,230 VAC supply.
S&F switch Piano type single pole two way 5 Amp,230 VAC supply. .
S&F socket two in one ,3 Pin 5 Amps 230 VAC supply, .
S&F switch Piano type single pole one way 15 Amp on laminated sheet top cover complete to all as spd (Sheet top cover incl in point wiring) .
S&F socket Pinao type 6 Pin 16 amp,230 VAC .
Supply & fixing PVC Lamp holder suitable for and including batten fittings ,LED Electric lamp 9 Watt with backalite 20mm back plate complete all as specified & directed, .
M&L for Ceiling Rose, surface bakelite 12 to 3 terminal, 240 volts, 5 Amp ISI marked complete all as specified and directed.
S&F Electric bell ding dong complete all as spd
S&F bell push flush type 5 Amp, complete all as spd
S&F of fan regulator step down electronic type heavy duly flush type 230 volts AC single phase fixed on laminated sheet top cover (laminated top cover is included in point wiring) and connecting up complete all as specified and directed. (Laminated sheet top cover and sunken box is included in point wiring).
M&L for LED 10W bulkhead fitting with IP-43 engineering plastic housing with clear ,single phase 240V, including 1.0sqmm copper flexible cable twiested three core alongwith flelxible PVC condiut from ceiling rose to fitting testing complete all as specified and directed .
Supply and fix LT main control board of CRCA sheet metal board of size 100cmX80 cm X 25 cm made out of 2 mm thick sheet vermin proof, including painting with 2 coats of synthetic enamelled paint over a coat of red oxide including copper busbar and fixed on/inside wall for fixing arrangement of existing electronic meter incl internal connection with suitable size of copper conductor wire and accessories , locking arrangement with opening handle comprises following euipments,internal wiring and termination of external cables, lugs nad glands and conduit as required including taking out of existing old unserviceable main control board comprising following : (A) Incoming :- MCCB 4P , 100 Amps, 415 Volts 16 KA - 01 Nos (B) Copper bus bar 200 Amps for phase and neutral and earth bar (C) Outgoing MCB SPN 40 Amps - 06 Nos. (D) Outgoing MCB SPN 10 Amps - 01 No.
S & F of MCB suitable for 240 volts AC supply, SP with over load and short circuit protection and rupturing capacity not less than 10 KA and 6 to 32 Amps all as specified and directed.
S & F of MCB suitable for 240 volts AC supply, SPN with over load and short circuit protection and rupturing capacity not less than 10 KA and 16 to 40 Amps all as specified and directed.
S&F Distribution board double door made out of CRCA mild steel sheet surface with insulated material like polyester or with powder coating surface mounting SPN 8 way 240 volts with bus bar rating 200 Amps dust and vermin proof suitable for incorporation of MCB's and isolators etc complete all as specified and directed..
S&F and testing LED light fitting 1x18watt 4 feet long including LED tube with driver complete suitable for fixation on wall/roof with body robust, corrosion resistant, superior finish and without any cracks or through h oles. The system wattage of fitting should not be more than 18 watt= 10%, surge protection of minimum 2 KV power factor should be more than 0.90 cool while colour, total hormonic distoration (THD) should not be more than 15% lumen output should not be less than 1700 lumens, total input voltage range 140-280V AC, colour rendering index should not be less than 80, Corelated colour should be minimum 6000 degree Kelvin.
M & L for Sub main wiring with 2 single core 6 Sqmm PVC insulated FRLS cable with multicore copper conductor drawn into and including PVC conduit rigid non metallic of suitable dia with and including independent PVC insulated one run 6 Sqmm single core copper earth wire complete all as specified. (Note:- Three lengths of 6 sqmm cable and will be measured as one length).
Taking down carefully, dismantling ceiling fan of any make sweep and size and reassembling after necessary repairs overhauling,greasing, oiling and replacement of worn out spares, sealing cable ends, dismantling blades, opening up for inspection and transportation to contractor’s workshop and back including hanging, fixing and connecting up and testing complete all as directed by Engineer-in-Charge. Note 1. Material and labour required for rewinding of fan motor shall be measured and paid for separately. 2. Spare parts where ever required for replacement shall be measured and paid for separately as supply only and fixing is including under this item.
Material & labour for rewinding of ceiling fan motor 1200/1400mm sweep with super enameled copper wire of existing specification, gauge and weight including insulating etc complete all as specified and as directed by Engineer-in-charge. Brand of copper wire -: Atlas / Devi Dyal/BPL
Supply and fixing only ball bearing of existing No. and size suitable for ceiling fan 1200 / 1400 mm sweep of any make including necessary greasing etc complete all as specified and as directed by Engineer-in-charge. Make: SKF/NBC
Supply and fixing only gun metal bush of existing No. and size suitable for ceiling fan 1200 / 1400 mm sweep of any make including necessary greasing etc complete all as specified and as directed by Engineer-in-charge. Make: SKF/NBC
Supply and fixing only Rubber bush of existing No. and size suitable for ceiling fan 1200 / 1400 mm sweep of any make including necessary greasing etc complete all as specified and as directed by Engineer-in-charge. Make: SKF/NBC
Supply and fixingonly Ceiling Fan Capacitor 3.15 MFD including necessary connections complete all as specified and as directed by Engineer-in-charge. Make : KELTRON / USHA / UNISTAR.
S&F for twin core twisted copper flexible wire/cable of size 23/.0076 for ceiling fan complete all as spd and dir .
Supply and fixing only top and bottom canopy with U clamp suitable for ceiling fan 1200 / 1400 mm sweep of any make including suitable colour match as existing complete all as specified and as directed by Engineer-in-charge. Make: SKF/NBC
S&F only down rod 300 mm long of size 20 mm dia for ceiling fan complete all as spd and dir.
S&F only Ceiling fan blade suitable for 1200/1400 mm sweep suitable for existing make & type as per sample complete all as spd and dir.
Taking down complete ceiling fan of size 1200/1400 mm sweep down rod with its accessories and filling the cavities with filler material and painting of ceiling fan removing old paint with brush and spray painting with two coats of synthetic enamelled paint after reassembling spares for serviceable condition complete all as specified and directed by Engr-in-Charge.
Taking down carefully, dismantling Exhaust fan of any make sweep and size and reassembling after necessary repairs overhauling,greasing, oiling and replacement of worn out spares, sealing cable ends, dismantling blades, opening up for inspection and transportation to contractor’s workshop and back including hanging, fixing and connecting up and testing complete all as directed by Engineer-in-Charge. Note 1. Material and labour required for rewinding of fan motor shall be measured and paid for separately. 2. Spare parts where ever required for replacement shall be measured and paid for separately as supply only and fixing is including under this item.
Material & labour for rewinding of Exhaust fan motor 250/300mm sweep with super enameled copper wire of existing specification, gauge and weight including insulating etc complete all as specified and as directed by Engineer-in-charge. Brand of copper wire -: Atlas / Devi Dyal/BPL
Supply and fixing only ball bearing of existing No. and size suitable for Exhaust fan 250 / 300 mm sweep of any make including necessary greasing etc complete all as specified and as directed by Engineer-in-charge. Make: SKF/NBC
Supply and fixing only gun metal bush of existing No. and size suitable forExhaust fan 250 / 300 mm sweep of any make including necessary greasing etc complete all as specified and as directed by Engineer-in-charge. Make: SKF/NBC
Supply and fixing only Rubber bush of existing No. and size suitable for Exhaust fan 250 / 300 mm sweep of any make including necessary greasing etc complete all as specified and as directed by Engineer-in-charge. Make: SKF/NBC
S&F for twin core twisted copper flexible wire/cable of size 23/.0076 for exhaust fan complete all as spd and dir .
S&F only exhaust fan blade suitable for 300/450 mm sweep suitable for existing make & type as per sample complete all as spd and dir.
Taking down complete exhaust fan of size 250/300 mm sweep with its accessories and filling the cavities with filler material and painting of exhaust fan removing old paint with brush and spray painting with two coats of synthetic enamelled paint after reassembling spares for serviceable condition complete all as specified and directed by Engr-in-Charge.
Disconnecting electrical/mechanical connections and taking down existing u/s storage type water heater (Geyser) Capacity 25 ltrs of any make,type and size by unscrewing nuts,bolts,washers and transporting to store yard of MES at Fazilka(site of repairs) where necessary repairs to be carried out, opening up , inspecting the defects jointly by contractor or his rep and Engg-in-charge,making joint inventories of defects to be rectified and spared to be replaced , re-assembling after repairs and replacement of spares, transporting back to the location from where taken down and fixing in original position and making the water and electrical connections, testing and making functional ect complete all as specified and directed by Engr-in-Charge. Note:- Replacement of spare parts such as Inner assembly, inner tank, glass wool & outer body shall be measured and paid separately under respective items.
Supply and fixing MS outer cover as per existing thickness with nuts , bolts,clamps,brackets duly painted with two coats of synthetic enamel paint with spray gun over a coat of red oxide primer rubber clamps base plate,screws etc for storage type water heater of capacity 25 Ltrs all as specified and directed by Engr- in-Charge.
Replacement of Geyser Inner tank of capacity 25 Ltrs including nut bolts, rubber sheet and necessary connected items and after repairing refixing the same at site making all electrical connections, testing, commissioning complete all as spd and dir by Engr-in-Charge.
Supply and fix compressed glass wool 48 mm thick between outer body and inner tank of geyser by means of adhesive all as specified and directed by Engr-in-Charge.
Supply and fixing geyser inner assembly 09 holes of brass with inlet/outlet & over flow provision rubber washer suitable for 25 ltrs capacity all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement heating element 1500 watt of suitable shape and size,any specification, confirming to ISI with PVC rubber washer clamps type all as specified and directed by Engr-in- Charge. Make: Daspass/Recold/Bajaj
S&F in replacement of thermostat of size 0-90, thermostat switch suitable for storage type geyser all as specified and directed by Engr-in-charge, Make :Daspass/Denfoss/Bajaj
S&F PVC Connection 450 mm long 15 mm for cold pipe line
S&F PVC Connection 450 mm long 15 mm for cold pipe line
Taking down complete storage type water heater (Geyser) of capacity 25 Ltrs with its accessories and filling the cavities with filler material and painting of geyser removing old paint with brush and spray painting with two coats of synthetic enamelled paint after reassembling spares for serviceable condition complete all as specified and directed by Engr-in-Charge.
KATARIA CONSTRUCTION
G S CONSTRUCTIONS
M/s Manoj Construction Co.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .