| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.1 LAccepted-AOC MOSUR HASSAN BARBHUIYA 2B APPIN PT II APPIN PT II PO LALA PS LALA HAILAKANDI PIN 788161 | HAILAKANDI | ASSAM | 788161 | ₹21.1 L | L1 | Accepted-AOC Lowest Bidder |
| 2 | L2₹21.1 L+₹1 (<0.01%)Rejected-AOC ARENGABAD CHARGOLA BAZAR DIST SRIBHUMI | SEPAHIJALA | TRIPURA | 799011 | ₹21.1 L+₹1 (<0.01%) | L2 | Rejected-AOC 2nd Lowest |
| 3 | L3₹26 L+₹4.9 L (23.1%)Rejected-AOC MOHANPUR PT III P O MOHANPUR P S ALGAPUR HAILAKNDI PIN 788150 | HAILAKANDI | ASSAM | 788150 | ₹26 L+₹4.9 L (23.1%) | L3 | Rejected-AOC 3rd Lowest |
| 4 | Rejected-Technical | - | - | Rejected-Technical Technically Dis-Qualified |
| 5 | Rejected-Technical SILCHAR CACHAR ASSAM | - | - | Rejected-Technical Technically Dis-Qualified |
Tender Value
₹23.5 L
EMD Value
₹46,949
Closing Date
26 Dec 2024, 2:00 pmClosed
SE PWD Silchar Building Circle Silchar
SE PWD Silchar Building Circle Silchar
Civil, Sanitary and Water supply and Electrical Work
2024_PWBNH_40758_1
SBC/CS/2024-25/10/501/Gr-V
Open Tender
Civil Works - Building
Item Rate
180 days
Katlicharra Hailakandi
As per NIT
5 documents required · 5 mandatory
₹500
₹46,949
Yes
SE PWD Silchar Building Circle Silchar
20 Jan 2025
4 Dec 2024
26 Dec 2024
4 Dec 2024
26 Dec 2024
4 Dec 2024
4 Dec 2024 - 26 Dec 2024
9 Dec 2024
Amount
Earthwork in surface excavation not exceeding 30cm in depth but exceeding 1.5m in width as well as 10 Sqm on plan including getting out and dispsal of excavatex earth upto 50m and lift upto 1.5m as directed by Engineer-in-Charge. All kinds of soil.
Earthwork in surface excavation not exceeding 30cm in depth but exceeding 1.5m in width as well as 10 Sqm on plan including getting out and dispsal of excavatex earth upto 50m and lift upto 1.5m as directed by Engineer-in-Charge. 2.1.1: All kinds of soil.
Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete : 16.12.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering. All work up to plinth level. 4.1.8 : 1:4:8 : (1 Cement : 4 coarse sand (Zone-III) derived from natural sources : 8 graded stone agreegate 40mm nominal size derived from natural gravel.
Brick work with common burnt clay F.P.S (non modular) bricks of class designation 7.5 in foundation and plinth in : 6.1.1 : Cement mortar 1:4 (1 cement : 4 coarse sand)
Brick work with common burnt clay F.P.S (non modular) bricks of class designation 7.5 in super structure above plinth level upto floor V level in all shapes and sizes Cemnent mortar 1:4
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). 9.1.2 : Sal wood.
Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-In-Charge. (Note : Butt hinges and necessary screws shall be paid separately). 9.5.1 : Second class teak wood. 9.5.1.2 : 30mm thick shutters
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. In layers not execeding 20cm in depth, consolidated each deposited layers by ramming and watering lead upto 50m and lift upto 1.50m.
Providing and laying 75 mm thick compacted bed of dry brick aggregate of 40 mm thick nominal size including spreading, well ramming, consolidating and grouting with jamuna sand, including finishing smooth etc. complete as per direction of Engineer-in-charge.
Providing and fixing M.S grills of required pattern in frames of windows etc with M.S flats, square or round bars etc including priming coat with approved steel primer all complete. 9.48.2 : Fixed to openings / wooden frames with rawlplugs screws etc.
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 10.25.2 In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering. All work up to plinth level. : 1:3:6 ( 1Cement : 3 coarse sand (Zone-III) derived from natural source : 6 graded stone aggregate 20mm nominal size derived from natural sources)
Centering and shuttering including strutting, propping etc and removal of form for Foundations, footings, bases of columns etc for mass concrete.
Centering and shuttering including strutting, propping etc and removal of form for 5.9.3 : Suspended floors, roofs, landing, balconies, and access platform.
Centering and shuttering including strutting, propping etc and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers.
Centering and shuttering including strutting, propping etc and removal of form for Columns, Pillars, Piers, Abutments, Posts and struts.
Centering and shuttering including strutting, propping etc and removal of form for Suspended floors, roofs, landings, balconies and access platform with water proof ply 12mm thick.
Centering and shuttering including strutting, propping etc and removal of form for Lintels. Beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12mm thick.
Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering and shuttering finishing and reinforcement. All work up to plinth level. 1:1.5:3 (1 Cement : 1.5 coarse sand (Zone-III) derived from natural sources : 3 graded stone aggregate 20mm nominal size derived from natural sources)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 5.2.2 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size)
Steel reinforcement for R.C.C work including straightening, cutting, bending placing in position and binding all complete upto plinth level. 5.22.6 : Thermo- Mechanically Treated bars of grade Fe-500D or more.
Steel reinforcement for R.C.C work including straightening, cutting, bending,placing in position and binding all complete above plinth level. 5.22.6 : Thermo- Mechanically Treated bars of grade Fe-500D or more.
Brick work with common burnt clay F.P.S (non modular) bricks of class designation 7.5 in foundation and plinth in :6.1.1 : Cement mortar 1:4 (1 cement : 4 coarse sand)
Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominal size derived from natural sources.)
Half brick masonry with common burnt clay F.P.S. (non modular) bricksof class designation 7.5 in superstructure above plinth level up to floor V level 6.13.2 Cement mortar 1:4 (1 cement :4 coarse sand)
Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
62mm thick cement concrete flooring with concrete hardener topping under layer 50mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mix @2 litre per 50 Kg of cement or as per manufacture"s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc complete.
15mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix :
12 mm cement plaster of mix : 13.4.1 1:4 (1 cement: 4 coarse sand)
15 mm cement plaster on rough side of single or half brick wall of mix: 13.5.1 1:4 (1 cement: 4 coarse sand
Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre
Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives. New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm.
Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : 13.61.1 Two or more coats on new work
Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting fixing in position and applying a priming coat of approved steel primer all complete.
Providing corrugated G.S Sheet roofing including vertical/ curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I limpet washers orwit G.I. Limpet etc of approved paint on over lapping of sheets complete (Upto any pitch in horizontal / Vertical or curved surfaces) 12.1.3 : 0.63mm thick with zinc coating not less than 275 gm/ Sqm.
Providing ridges or hips of width 60cm overall width plain G.S. Sheet fixed with polymer coated J or L hooks, bolts and nuts 8mm dia G.I limpet and bitumen washers complete. 12.4.2 : 0.63mm thick with zinc coating not less than 275 gm/M2
Providing and fixing false Ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S sheets and galvanized with zinc coating of 120 gms/ sqm (both side inclusive ) as per IS: 277 and consisting of angle cleats of size 25mm wide x 1.6mm thick with flanges of 27mm and 37mm, at 1200mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25 x 10 x 0.50mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I channels 45 x 15 x 0.90mm running at the spacing of 1200mm centre to centre, to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26mm each having lips of 10.5mm, at 450mm centre to centre , shall be fixed in a direction perpendicular to G.I intermediate channel with connecting clips made out of 2.64mm dia x 230mm long G.I wire at eevery junction, including fixing perimeter channels with the help of dry wall screws of size 3.5 x 25mm at 230mm c/c, including jointing and finishing with jointing compound in 3 layers covering upto 150mm on both sides of joint and two coats of primer suitable for board, all as per manufacture's, specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer-In-charge but excluding the cost of painting with : 12.45.1: 12.5mm thick tapered edge gypsum plain board conforming to IS:2095-(Part-I) : 2011 (Board with BIS certification marks).
Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance ±1mm), with wall thickness 2.0 mm (± 0.2 mm), corners of the door frame to be Jointed with galvanized brackets and stainless steel screws, joints mitred and Plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer’s specification and direction of Engineer -in-Charge. 9.117.1: Extruded section profile size 48x40mm.
Providing and fixing to existing door frames. 9.118.1 24 mm thick factory made PVC door shutters made of styles and rails of a uPVC hollow section of size 59x24 mm and wallthickness 2 mm (± 0.2 mm) with inbuilt edging on both sides. The styles and rails mitred and joint at the corners by means of M.S. galvanised/ plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 20x20 mm and 1 mm (± 0.1 mm) wall thickness. The lock rail made up of 'H' section, a uPVC hollow section of size 100x24 mm and 2 mm (± 0.2 mm) wall thickness, fixed to the shutter styles by means of plastic/galvanised M.S. 'U' cleats. The shutter frame filled with a uPVC multi-chambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm (± 0.1 mm) wall thickness. The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacturer's specification and direction of Engineer-in-charge. (For W.C. and bathroom door shutter).
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, etc. 21.1.1.1 Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): 21.3.2 With float glass panes of 5 mm thickness (weight notless than 12.50 kg/ sqm)
Providing and applying white cement based putty of average thickness 1mm of approved brand and manufacturer, over the plastered wall surfaceto prepare the surface even and smooth complete.
Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound) content less than 50 grams/ litle of approved brand and manufacture, including applying additional coats wherever required to achieved even shade and colour.
Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 17.1.1 White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : 17.32.2 Rectangular shape 453x357 mm
Providing and fixing 600x120x5 mm glass shelf with edges round off, supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete.
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conformingto IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 12.42.5 Bend 87.5° 12.42.5.2 110 mm bend
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conformingto IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion 12.42.3 Single tee with door 12.42.3.2 110x110x110 mm
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conformingto IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion 12.42.4 Single tee without door 12.42.4.2 110x110x110 mm
Gravel packing in tubewell construction in accordance with IS: 4097,including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge.
Providing fitting and fixing 450mm dia, 90mm thick C.I. Man hole cover and frame of 58 Kg. Weight complete as directed and specified.
Construction of 1.80 metre high Boundary wall with 1.65m high chainlink fensing on angle iron post embeded to CC basw 250mmx 250mm placed @2.50m apart and .30m high brick wall wiith plaster and colouring
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. 1.8.1 Group A
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. 1.8.2 Group B
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. 1.8.3 Group C
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth level.5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D or more.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 1.14.1 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 1.14.2 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 1.14.5 2 X 10 sq. mm + 1 X 6 sq. mm earth wire
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. 1.23.3 15/16 A switch
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. 1.23.4 3 pin 5/6 A socket outlet
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. 1.23.5 6 pin 15/16 A socket outlet
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. 1.23.8 Bell push
Supplying and fixing brass batten/ angle holder including
Installation, testing and commissioning of pre-wired,fluorescent fitting / compact fluorescent fitting of all types,complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc.as required.
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
Supplying and fixing following way, single pole and neutral,sheet steel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without CB/RCCB/Isolator) 2.3.2 8 way , Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 2.10.1 Single pole
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 2.10.2 Single pole and neutral
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
Supply, installation, testing & commissioning of 1200 mm sweep BEE sotas rated ceiling from including all accessories safety pin ,nut & bolts washess /suitable for 230 V, 50H2, single phase Ac supply eartthing etc complete as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.
Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required 14.13.3 100 mm dia
Supplying installation testing and commissioning of Solar sheet light with IP65 Led fixture with light efficiency mono crystalliue solar panel and LiFe PO4 battery ,MPPT charge controler with PIR senxt complete with accessoreies as directed & specified by the deptt. b) 20 wall in one integrated solar sheet light with 40 W momone crystallive panel ,21 AhLiFe PO 4 battery MPP charge controler with PIR etc
Supplying installation testing and commissioning of Solar roof top off grid system with PV module, MS frame for fitting & fixing of PV module panel, battery bank etc complete as directed & specified by the deptt. b) Solar roof top off grid PV module of 1 Kwp, PCU of 1KVA, 48 V, single phase, battery bank of 48V/150 AR.
Supplying with fitting & fixing of 7 watt LED lamlb (Anchor/Panasonic make )
Supplying with fitting & fixing of LED batten tube light 20 watt 4 ft length including canectain etc (Anchor)
RAJAN DEY (BID ID -252910)
U G BUILDER AND CONSULTANCY (BID ID -252916)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .