Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹66.0 LAccepted-AOC F 402 AMBIKA APARTMENT PLOT A 9 SECTOR 20 NERUL W NAVI MUMBAI 400 706 | THANE | MAHARASHTRA | 400706 | ₹66.0 L Quoted ₹67.1 L | L1 | Accepted-AOC AOC |
| 2 | L2₹75.2 LRejected-Finance A 14 USHA SADAN NEAR POST OFFICE COLABA MUMBAI 05 | MUMBAI | MUMBAI | MAHARASHTRA | 400005 | ₹75.2 L | L2 | Rejected-Finance Other Than Being Lowest |
| 3 | L3₹75.5 LRejected-Finance 1202 SAI PROVISO DHNISHT PLOT NO 72 73 SECTOR 20 KOPARKHAIRANE NAVI MUMBAI | THANE | MAHARASHTRA | 400601 | ₹75.5 L | L3 | Rejected-Finance Other Than Being Lowest |
| 4 | L4₹76.9 LRejected-Finance | ₹76.9 L | L4 | Rejected-Finance Other Than Being Lowest |
| 5 | L5₹89.0 LRejected-Finance SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON W MUMBAI 400 104 | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | ₹89.0 L | L5 | Rejected-Finance Other Than Being Lowest |
| Sl No | Description | Qty | Unit | ASHOK ENTERPRISES L3 | Shetty Construction Co L4 | Advait Enterprises L1 | Shree Ayyappa Engineering L5 | S S ENTERPRISES L2 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Routine maintenance of STP (Sewage treatment Plant) installed at Vandana and Vishakha complex having capacity of treatment 200 KL/day, maintenance of entire system, filtration/ dosing system carrying out the routine maintenance recommended by the manufacturer for daily, weekly, monthly and quarterly including repairs/ replacement of parts such as bearings, repairs of pumps, filters, welding of cracked/ broken any mild steel items/ foundation, pipes and their fittings, gasket, nut bolts and removing of blocking/overflow systems, LT panel boards etc complete all as specified & directed by Engineer-in-Charge the following items : (a) Fine bar screen & Oil Grease tank - 01 Nos
(b) Oil and grease trap chamber -01 Nos
(c) Equalization tank - 01 (d) ANOXIC chamber -01, (e) Clarified water tank -01, (f) Treated water tank -01 (g) Sludge Holding tank -01 (h) MBBR Tank -01, (j) Raw sewage pump - 02, (k) Sewage reccee pump -02 (l) Filter feed pump -02 (m) Screw pump -02, (n) Treated water pump -02 (o) Air blower -02 and all butter fly valve, pipe line inside STP and LT Panel - 02 Nos, complete dosing system including cleaning of STP area daily as directed .(p) The record of lab testing of treated water samples will also maintained in similar way.The cost of same is deemed in the unit rate quoted & the report submitted to the Engineer-in -Charge at every month. | 11 | Per Month | 8,500 ₹93,500 | 5,500 ₹60,500 | 3,700 ₹40,700 | 2,400 ₹26,400 | 40,000 ₹4,40,000 |
| 2.00 | Taking down old rusted and damaged blower filter and supply and fixing blower filter as per existing size and sample at site all as directed. | 2 | Each | 7,000 ₹14,000 | 18,000 ₹36,000 | 28,000 ₹56,000 | 18,000 ₹36,000 | 30,000 ₹60,000 |
| 3.00 | Supply and use sodium hypochlorite ,( as per Particular specification), liquid specification include a clear, pale yellow- green appearance ,free alkali and free sodium carbonate , in sealed HDPE container of 100% concentration of standard capacity all as specified and directed. [Note : Necessary chemicals and testing kit (residual chlorine & PH) for testing of water samples at lab shall be provided by the Contractor and cost of the same shall be deemed in the unit rate quoted.] | 200 | Ltr | 225 ₹45,000 | 300 ₹60,000 | 300 ₹60,000 | 230 ₹46,000 | 250 ₹50,000 |
| 4.00 | Supply and use chemical DWPE (Dewatering polyelectrolyte) of 100% concentration of standard grade complete all as specified and directed. | 250 | Kg | 250 ₹62,500 | 425 ₹1,06,250 | 300 ₹75,000 | 280 ₹70,000 | 185 ₹46,250 |
| 5.00 | Cleaning of RCC sewage fine bar screen chamber of size 1.2m x 0.5 m x 1.0m including washing removing the scales dust , removing of sludge etc including plugging the insects dusting washing, internal/ external paint complete all as all as specified & directed. | 1 | Each Job | 3,800 ₹3,800 | 7,500 ₹7,500 | 7,500 ₹7,500 | 6,300 ₹6,300 | 25,000 ₹25,000 |
| 6.00 | Cleaning of RCC sewage Oil and Grease trap chamber of size 1.75m x 1.2 m x 2.5 m including washing removing the scales dust , removing of sludge etc including plugging the insects dusting washing, internal/ external paint complete all as all as specified & directed. | 1 | Each Job | 4,000 ₹4,000 | 10,000 ₹10,000 | 7,900 ₹7,900 | 6,500 ₹6,500 | 25,000 ₹25,000 |
| 7.00 | Cleaning of RCC ANOX IC tank of size 2.1 m x 2.1 m x 4.5 m including washing removing the scales dust , removing of sludge etc including plugging the insets dusting washing, internal/ external paint complete all as all as specified & directed | 1 | Each Job | 4,200 ₹4,200 | 10,000 ₹10,000 | 7,900 ₹7,900 | 7,500 ₹7,500 | 20,000 ₹20,000 |
| 8.00 | Cleaning of treated water tank of size 4.0m x 3.7 m x 2.5 m by rubbing, washing removing the scales dust etc including plugging the insets dusting washing and painting complete all as specified and directed | 1 | Each Job | 4,000 ₹4,000 | 18,000 ₹18,000 | 8,000 ₹8,000 | 7,500 ₹7,500 | 12,000 ₹12,000 |
| 9.00 | Cleaning of RCC sludge holding tank of size 1.7 m x 6.0 m x 1.5m by rubbing, washing removing the scales dust etc including plugging the insets dusting washing and painting complete all as specified and directed | 1 | Each Job | 4,000 ₹4,000 | 15,000 ₹15,000 | 9,500 ₹9,500 | 8,500 ₹8,500 | 18,000 ₹18,000 |
| 10.00 | Repair and maintenance of filter press with replacement of filter press cloth and minor parts complete all as specified and directed | 1 | Each Job | 4,000 ₹4,000 | 10,000 ₹10,000 | 9,000 ₹9,000 | 10,000 ₹10,000 | 5,000 ₹5,000 |
Tender Value
₹1.2 Cr
EMD Value
₹2.0 L
Closing Date
26 Jan 2026, 6:00 pmClosed
CWE (NW) Mumbai
CWE (NW) Mumbai
REPAIR MAINTENANCE OF WATER SUPPLY PIPELINES PUMPS SETS VALVE PITS, PANELS AND EARTHING OF OUTLAYING AND REPLACEMENT OF COMPONENTS OF STP, RO PLANT AND OTHER MISC ITEMS AT OUTLYING AREA UNDER GE (NW) NOFRA COLABA MUMBAI
2025_MES_745406_1
8669/CWE(NW)Mumbai/E8
Open Tender
Civil Works
335 days
GE (NW) NOFRA
Class B
Category a(ii)
7 documents required · 7 mandatory
₹1,000
GE (NW) NOFRA
₹2.0 L
Yes
18 Mar 2026
20 Dec 2025
28 Jan 2026
20 Dec 2025
26 Jan 2026
14 Jan 2026
20 Dec 2025 - 10 Jan 2026
M&L for attending leakage complaints in pump house/ high rise building by checking centrifugal pump / NRV / sluice valve/Non return valve/gate valve of pipe line leakage including replacement of unseriviceable component including preventive maintinance spares by replacing minor parts i.e galand packing nut and bolts complete all as specified and as directed. Note :- If the contractor will not attend the complaints by his trades man in any working day /holiday including sunday the necessary reovery of Rs. 500/- per day shall be imposed complete all as specified and directed .
Supply and use chemical DWPE (Dewatering polyelectrolyte) of 100% concentration of standard grade complete all as specified and directed.
Taking down old submersible cable copper conductor and Supply & fixing flat type 2.5 sqmm 3 core complete all as specified & directed.
As per item No 12.00 here in above but 5 HP to 7.5 HP motor
As per item No 12.00 here in above but 10 HP to 12.5 HP motor
As per item No 12.00 here in above but 15 HP to 20 HP motor
Material and labour for attending Raw water supply complaints and rectification as mentioned below here in after Internal complaint (in side Room) Including Flush tank Cleaning 2 nos [Note :- for item no 29.00 to 33.00 (a) Scaffolading if any required during the progress of work the contractor sha
ll provide the same with out any extra cost to the department the rates quoted shall be deemed inclusive of this provision (b) Necessary complaint book shall be provided and maintained by the contractor, complaint slip shall be deposited very next day in the complaint cell of Vishakha/ Vandana w/s duly signed by the occupant (c) Rates for small fittings and parts are deemed to be included in item rate however pipes, valves, PVC connection shall be measured and paid for separately under relevent items of schedules.]
Supply and fix 25 mm bore steel water tubing galvanised medium grade (ISI Marked) of following size, with all fitting fixed complete to walls and ceilings or laid in floor/wall/ceiling (in high rise building including scafolding) including taking down old complete all as specified and directed .
Supply and fix in repair gun metal gate valve 20 mm bore, ,ISI marked with iron wheel head, screwed both ends for GI pipe of following sizes, with union, (ISI Marked) fixed in existing line and in position complete all as specified and directed.
Ditto as per item No 29.00 here in above but External complaint upto 16th floor
Supply and fix in repair gun metal gate valve 25 mm bore,ISI marked with iron wheel head, screwed both ends for GI pipe of following sizes, with union, (ISI Marked) fixed in existing line and in position complete all as specified and directed .
Supply only Antiscalant chemical for RO Plant (Make : As approved )
Supply only cleaning Chemical for RO Plant (Make: As approved )
Disconnecting and taking out unserviceable multiple valve and supply fix with new multiple valve of RO plant complete to match the existing and connecting up with existing system including all accessories complete all as specified and directed by Engineer-in-Charge. Make :- As approved
Cleaning and painting external surface with cement based paint complete, colour as existing Semi under ground RCC sump of cap 01 lakh ltrs after draining out scraping out bottom and side of wall with wire brush and bleaching powder, removing scaling fungus, flushing thoroughly with clean water, applying on coat of white washing after drying inside, writing of tank capacity and date of cleaning and due date of cleaning in capital letters of 20mm size on external surface of wall with white enamel paint over black paint surface all as specified and directed
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth and taking out soft/loose soil for laying of cable /evection of pole/stay pit excavation/pipe line complete all as specified and directed
Returning and filling including spreading levelling watering and well ramming in layers not exceeding 25 cm complete all as specified and directed
Taking down the broken rubber coupling from 60 HP to 75 HP motor / pump and fixing the new coupling with cotter pin, rubber piece and nut bolts in position as per approved make complete all as specified and directed.
Taking down the broken rubber coupling from 40 HP to 60 HP motor / pump and fixing the new coupling with cotter pin, rubber piece and nut bolts in position as per approved make complete all as specified and directed.
Taking down the broken rubber coupling from 05 HP to 300 HP motor / pump and fixing the new coupling with cotter pin, rubber piece and nut bolts in position as per approved make complete all as specified and directed.
Supply & fixing in relacement non return valve (ISI marked) of CI body 80mm to100 mm bore flanged with rubber packing including nuts bolts and wahsers etc complete all as specified and directed.
Supply & fixing in replacement non return valve (ISI marked) of CI body 150mm to 200 mm bore flanged with rubber packing including nuts bolts and wahsers etc complete all as specified and directed.
Supply and fix in replacement Fresh water tankcast iron lid, including locking arrangements black paint in /out side fixed on RCC water tank on top of building cap of tank 20000 gallons capacity complete all as specified and directed.
Supply & fix in replacement foot valve, 50 mm size ISI marked PN-1.6 pressure rating including all joints with rubber or fibre board, bolts, nuts washers, etc complete all as specified and directed.
Supply & fix in replacement foot valve, 80 mm size ISI marked PN-1.6 pressure rating including all joints with rubber or fibre board, bolts, nuts washers, etc complete all as specified and directed.
Supply & fix in replacement foot valve,100 mm size ISI marked PN-1.6 pressure rating including all joints with rubber or fibre board, bolts, nuts washers, etc complete all as specified and directed.
Supply & fix in replacement foot valve,150 mm size ISI marked PN-1.6 pressure rating including all joints with rubber or fibre board, bolts, nuts washers, etc complete all as specified and directed.
All as per item No 105.00 here in before but pump of capacity 40 HP complete all as specified and directed.
M&L for disconnecting the unserviceable pump set of capacity 60 to 75 HP any make from the pump foundation after opening nuts/bolts, transporting from site to workshop, dismantling pump, removing worn out impeller, ball bearing, gasket, and replacement the unserviceable parts , gland packing, greasing, transporting back to pump house and refixing up on the existing foundation, connecting the electrilc supply to the motror and testing complete to entire satisfaction of Engineer-in-Charge all a speciied and directed..
All as per item No 105.00 here in before but pump of capacity 30 HP complete all as specified and directed.
All as per item No 105.00 here in before but pump of capacity 10/15 HP complete all as specified and directed.
All as per item No 105.00 here in before but pump of capacity 5/7.5 HP complete all as specified and directed.
All as per item No 105.00 here in before but pump of capacity 2/3 HP complete all as specified and directed.
All as per srl item No. 111 here in before but Motor of capacity 40 HP
Material and labour for rewinding the electric motor of capacituy 60HP to 75 HP capacity, disconnecting the electtic connection of motor, earth connections, decoupling motor and pump, removing foundation nuts/bolts and removing the motor from its existing position to workshop (Note:- following workds deemed to be included in the quoted rates.) (a) Removing the split case/body cover of motor, seperate stator/rptar and cutting the complete burnt/defective copper winding. (b) Cleaning the stator body complete by rubbing and paper removal all carbons. (c) Insert insulating materials such as insulating paper sleeves. (d) Rewinding the stator with existing size of super enameled copper winding, varnishing and heaating up at desired temperature for achieve the particular Ohm resistance. (e) Clean the rotor and assembling in motor. (f) Connecting/coupling the motor with pump, connect all electric/earth connection foundation nuts.bolts at its original position and testing on load and complete all as specified and directed.
M & L for dismantling the rusted foundation bed of the motor and pump set, and fabrication of the forundation beds with MS channels angle of the required as per pump set capacity( 40 HP to 75 HP) and duly applying one coat of red oxide primer and two coat of bitumen paint of approved quality and re errection the pump and motor testing to the entire satisfaction of Engineer-in-Charge. [Note:- (a) Quoted rate deemed to be included for welding work, nuts, bolts, washer and MS fasteners including Concrete required for foundation]
M & L for dismantling the rusted foundation bed of the motor and pump set, and fabrication of the forundation beds with MS channels angle of the required as per pump set capacity( 20 HP to 35 HP) and duly applying one coat of red oxide primer and two coat of bitumen paint of approved quality and ieerrction the pump and motor testing to the entire satisfaction of Engineer-in-Charge. [Note:- (a) Quoted rate deemed to be included for welding work, nuts, bolts, washer and MS fasteners including oncrete required for foundation]
Supply & fixing in replacement of high pressure single head gear motored adjustable dosing pump with accessories include lead tubing, connecting nuts, injection check valve, clay weight, ferules etc complete all as specifed and directed.
All as per srl item No. 111 here in before but Motor of capacity 10/15 HP
Supply and Fixing in replacement of dosing system consisting 40 ltr-100 ltr PE/FRP Tank with PE/FRP Lid & level gauge along with agitator with shaft & blade in plastic tank complete all as specified and directed.
Taking out old unserviceable membranes and supply & fix new Reverse Osmosis membrane for RO plant of cap 40000 LPD (as per existing) all as specified and directed.
Disconnecting all electric connections from the chlorine dosizing motor 1.5 HP & taking out and rewinding the same motor with copper winding and refixing the same postion and testing complete all as specified and directed .
Supply and fix in replacement of butterfly valve (ISI Marked)of PN 1.0 of dia 100mm complete all as specified and directed.
Supply and fix in replacement of new butterfly valve (ISI Marked) of PN 1.0 of dia 150mm complete all as specified and directed
Supply and fixing in replacement 40 mm of gun metal globe or gate valves, (ISI Marked) with iron whel head, screwed both endes for iron pipe complete all as specified and directed
Supply and fixing in replacement 50mm of gun metal globe or gate valves,(ISI Marked) with iron whel head, screwed both endes for iron pipe complete all as specified and directed.
Supply and fixing in replacement 80 mm of gun metal globe or gate valves,(ISI Marked) with iron whel head, screwed both endes for iron pipe complete all as specified and directed.
M&L for disconnecting all electric connections from the submersible pump & motor 03 HP and taking out column assly from bore well and transporting the same to civil workshop for repair including winding etc complete all as specified and directed.
All as per srl item No. 111 here in before but Motor of capacity 30 HP
Taking down old leakage sand media filter vessel and supply and fix sand filter vessel polyethylene material, volume 450 Ltrs, pressure 10 bar for RO plant of capacity 40000 LPD complete all as specified and directed .
Disconnect the electric connections form starter and taking out burnt submersible starter from the existing position and supply and fixing new water sensor, starter 3 phase of 10HP , 440 Volt , front side openable and locking arrangement all as per directed .
M&L for attending underground pipe line leakage complaints of pipe of bore 80 mm to 150 mm upto 2 mtr depth line in any type of soil/ hard standing/ under road including earth work/welding work and labour charges complete all as specified and directed by Engr in Charge. Note : any pipe/ pipe fittings/rubber packing/any type of joint required for stop the leakage up to 5 mtr length of pipe included in the same rate.
Taking down oldunserveciable power contractor of any make and supply and fix 3 pole power contaractor ML-4 suitable for motor upto 40 HP complete all as specified and directed. Make- as approved, all as specified and directed.
M&L for attending underground pipe line leakage complaints of pipe of bore 20 mm to 63 mm upto 2 mtr depth line in any type of soil/ hard standing/ under road including earth work/welding work and labour charges complete all as specified and directed by Engr in Charge. Note : any pipe/ pipe fittings/rubber packing/any type of joint required for stop the leakage up to 5 mtr length of pipe included in the same rate.
Taking down of leakage /rusted not grether than of 3 mtrs 100 boreGI suction pipe from the existing position pump house and replace with new GI pipe line of size by threading / welding work / bend /, flanged / , nut, bolts /, labour charge all as directed
Supply and laying GI tubing 15 mm bore medium grade with all fitting such as tee, socket, bend, union etc in wall/trenches including taking down old rusted pipe complete all as specified and directed .
Supply and laying GI tubing 20 mm bore medium grade with all fitting such as tee, socket, bend, union etc in wall/trenches including taking down old rusted p
ipe complete all as specified and directed .
Supply and laying GI tubing 40 mm bore medium grade with all fitting such as tee, socket, bend, union etc in wall/trenches including taking down old rusted pipe complete all as specified and directed .
Supply and laying GI tubing 50 mm bore medium grade with all fitting such as tee, socket, bend, union etc in wall/trenches including taking down old rusted pipe complete all as specified and directed .
Supply and laying GI tubing 80 mm bore medium grade with all fitting such as tee, socket, bend, union etc in wall/trenches including taking down old rusted pipe complete all as specified and directed .
Supply and laying GI tubing 100 mm bore medium grade with all fitting such as tee, socket, bend, union etc in wall/trenches including taking down old rusted pipe complete all as specified and directed .
Supply and laying GI tubing 150 mm bore medium grade with all fitting such as tee, socket, bend, union etc in wall/trenches including taking down old rusted pipe complete all as specified and directed .
M & L for in repair maintenance free chemical earthing of environment friendly earth electrod set comprising of 17.2 mm dia , 3 m long rod low carbon steel molecular copper bounded for a thickness of 250 micro Omhs highly conductive ANS/INSF STD -60 certified carbon bound backfill compound which shall set like concrete accordingly to BS 7430 & IEEE 80 each bag shall contain 50 ibs complete ass as specified and directed.
M&L for Welding work any type Gas welding/ electric welding for any tpye and in any position including cutting jointing completed as directed
Supply and fix bronze impeller suitable for 60/75 HP pump all as per manufacturer's design as per staging and eye of the impeller complete all as per specified and directed.
Supply and fix bronze impeller suitable for 40 HP pump all as per manufacturer's design as per staging and eye of the impeller complete all as per specified and directed.
Supply and fix bronze impeller suitable for 20 HP pump all as per manufacturer's design as per staging and eye of the impeller complete all as per specified and directed.
Dismantling of Damaged/Burnt MCCB and Supply & fixing of MCCB,3 Pole, 630 Amps, 36kA, 415Volts,50Hz AC s complete all as specified
Dismantling of Damaged/Burnt MCCB and Supply & fixing of MCCB,4Pole, 400 Amps, 25kA, 415Volts,50Hz AC s complete all as specified and directed
Dismantling of Damaged/Burnt MCCB and Supply & fixing of MCCB,4Pole, 200 Amps, 25kA, 415Volts,50Hz AC s complete all as specified and directed
Dismantling of Damaged/Burnt MCCB and Supply & fixing of MCCB,4Pole, 160 Amps, 25kA, 415Volts,50Hz AC s complete all as specified and directed
Dismantling of Damaged/Burnt MCCB and Supply & fixing of MCCB,3 Pole, 200 Amps, 25kA, 415Volts,50Hz AC s complete all as specified and directed
Dismantling of Damaged/Burnt MCCB and Supply & fixing of MCCB,3 Pole, 160 Amps, 25kA, 415Volts,50Hz AC s complete all as specified and directed
M & L for area cleaning of water supply installation including clearing of veglitation, wild growth and trimming of grass etc around the water storage tanks, valve pits and installation compound and removing rubbish off the premises complete including spreading of suitable chemicals as approved for further growth of weeds and vegtation in the vicinity of installations complete all as specified and as directed.
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.41 MB
8669.rar
Tender Documents • 3.08 MB
BOQ_834663.xls
BOQ • 3.70 MB
Download all tender documents and submit your bid