Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.6 LAccepted-AOC 94 PHASE II HOUSEING COLONY UDHAMPUR J K | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L1 | Accepted-AOC LOWSET BIDDER | |
| 2 | L2₹13.8 L+₹16,163.20 (1.18%)Rejected-AOC 1 181 KAMATCHI AMMAN KOVIL STREET KANNAN COLONY CHINTHAMANI MADURAI 625009 | MADURAI | MADURAI | TAMIL NADU | 625009 | L2 | Rejected-AOC OTHER THAN LOWSET BIDDER | |
| 3 | L3₹14.8 L+₹1.2 L (8.66%)Rejected-AOC 13 P N DOGRA MARKET GOLE MARKET UDHAMPUR 182101 J K | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L3 | Rejected-AOC OTHER THAN LOWSET BIDDER | |
| 4 | L4₹15.5 L+₹1.8 L (13.5%)Rejected-AOC | L4 | Rejected-AOC OTHER THAN LOWSET BIDDER | |
| 5 | Rejected-Technical | - | Rejected-Technical Not Approved |
Tender Value
₹14.5 L
EMD Value
₹29,040
Closing Date
27 Apr 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SHRI A K DUBEY
Military Engineer Services, Commander Works Engineer, Udhampur, PO - Garhi, Udhampur-182121
PROVN OF DSC GAURDS POST ROOM AT MAIN GATE IN CH (NC) UNDER GE (NORTH) UDHAMPUR
2021_MES_427865_1
CWE/U(N)-107/2020-21
Open Tender
Civil Works
Lump-sum
180 days
UDHAMPUR
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE (NORTH) UDHAMPUR
₹29,040
Yes
5 Jun 2021
4 Mar 2021
29 Apr 2021
4 Mar 2021
27 Apr 2021
15 Apr 2021
60 days
Amount
BUILDING WORK (SCHEDULE 'A' PART-I) Lump sum price worked out by the Contractor for “Building Work” as listed in Schedule ‘A’ Part- I.
Internal Water Supply (SCHEDULE 'A' PART-II) Lump sum price worked out by the Contractor for “Internal Water Supply” as listed in Schedule ‘A’ Part- II .
INTERNAL ELECTRIFICATION (SCHEDULE 'A' PART-III)(SEC-I) Lump sum price worked out by the Contractor for “Internal Electrification” as listed in Schedule ‘A’ Part- III (Sec-I)
INTERNAL ELECTRIFICATION (SCHEDULE 'A' PART-III) (SEC-II) SCHEDULE `A' PART-III, Sec-II is not prepriced by MES and prepriced rates indicates 0.0 under column 5 signified this fact only. Bidder shall insert their rates in Green filed under Col-6.
Decorative ultra slim linear surface mounted LED lighting fixture (4 feet length), 20Watt LED with integral electronic driver complete making connection and testing after fixing all as specified and directed by Engr-in-charge.The specification of light fitting should meet the following : - (a) Housing of Light fitting : Aluminium Extruded (b) Operating Voltage : Between 150 V- 270V (c) Operating Temperature : -10 to +45 Degree Centigrade (d) Lumen efficacy : Not less than 110 lm/W (e) System Lumens : Not less than 2000 lm (f) Colour Temperature : Not less than 5700K (g) Surge Voltage Protection : Up to 2KV (h) Ingress protection : IP 20 (j) Total Harmonic Distortion (THD) : less than 20% (k) Power factor : Not less than : 0.90 (l) Line protection : Under/Over voltage Protection (m) Input Frequancy : 50 Hz
Decorative ultra slim linear surface mounted LED lighting fixture (2 feet length), 10 Watt LED with integral electronic driver complete making connection and testing after fixing all as specified and directed by Engr-in-charge.The specification of light fitting should meet the following : - (a) Housing of Light fitting : Aluminium Extruded (b) Operating Voltage : Between 150 V- 270V (c) Operating Temperature : -10 to +45 Degree Centigrade (d) Lumen efficacy : Not less than 100 lm/W (e) System Lumens : Not less than 1000 lm (f) Colour Temperature : Not less than 5700K (g) Surge Voltage Protection : Up to 2KV (h) Ingress protection : IP 20 (j) Total Harmonic Distortion (THD) : less than 20% (k) Power factor : Not less than : 0.9 (l) Line protection : Under/Over voltage Protection (m) Input Frequancy : 50 Hz
MCB SPN 40 to 63 Amps ( ISI Marked) 50 C/S 10 KA 'B' sereis complete all as specified.
MCB SP 5 to 32 Amps ( ISI Marked) 50 C/S 10 KA 'B' sereis complete all as specified.
Non metallic ventilating fan 150 mm sweep 240 Volts AC single phase complete with lovers and shutters including provision of flexible three core copper conductor cable of 23/0.0076 up to ceiling rose complete all as specified and directed by Engr- in-charge.
Vertical electric water heater (Geyser) storage type with PVC/thermoplastic body, Single phase AC supply, 230 volts 50 Hz , BEE 5 star rating, pressure rating 8 bar, steel /copper inner tank with glass liner/polymer protective coating with thermal cut off, ON/OFF indication lamps, safety valave of capacity 25 Ltrs including suitable size heavy duty PVC connection hot & cold and grouting fashner with suitable size on the wall as per site requirment all as specified and directed by EIC.
Sub Total
PATH (SCHEDULE 'A' PART-IV) Lump sum price worked out by the Contractor for “PATH” as listed in Schedule ‘A’ Part- IV .
EXTERNAL ELECTRIFICATION (SCHEDULE 'A' PART-V) Lump sum price worked out by the Contractor for “External electrification” as listed in Schedule ‘A’ Part- V .
SEWAGE DISPOSAL (SCHEDULE 'A' PART-VI) Lump sum price worked out by the Contractor for “Sewage Disposal” as listed in Schedule ‘A’ Part- VI
EARTH WORK AND SITE CLEARANCE (SCHEDULE 'A' PART-VII) Lump sum price worked out by the Contractor for “Earth work and site clearance” as listed in Schedule ‘A’ Part- VII .
R K BUILDERS
VARDHMAN INTERNATIONAL
s l sharma and sons
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .