Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.5 LAccepted-AOC AT RAY COLLIERY POST CHURI DIST RANCHI 829209 | HAZARIBAGH | JHARKHAND | 829209 | ₹2.5 L Quoted ₹2.1 L | L1 | Accepted-AOC L1 |
| 2 | Rejected-Technical | - | - | Rejected-Technical L2 |
| 3 | Rejected-Technical | - | - | Rejected-Technical L3 |
Tender Value
₹2.3 L
EMD Value
₹2,879
Closing Date
11 Jul 2022, 5:00 pmClosed
project engineer, ray bachra
Office of the Project engineer(EnM), Ray Bachra
Wiring/rewiring at Unit Store building under Ray-Bachra Project, PPR Area.
2022_CCL_248548_1
PE(EnM)/BCH/e-NIT/22-23/04
Open Tender
Electrical and Maintenance Works
Item Rate
7 days
Bachra
2 documents required · 2 mandatory
₹2,879
21 Oct 2022
1 Jul 2022
12 Jul 2022
2 Jul 2022
11 Jul 2022
2 Jul 2022
2 Jul 2022 - 8 Jul 2022
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and\ earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.Group A
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of ollowing poles in the existing MCB DB complete with connections,testing and commissioning etc. as required.Single pole
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of ollowing poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole & neutral.
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25 Amp
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Supplying and drawing 2x2.5 Sqmm sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required
Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required.
10.0 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable. For service wire.
12 way, SPN, double door, MCB DB
Supply & fixing of Brass batten/ angle holder
Supply & fixing of 50W LED Flood light
Supply & fixing of 20W LED tube light
Supply & fixing of Wall Fan
CPOH 15% of item no.9 to 14
Total impact of GST for the purpose of CTC
M/S DEO KUMAR SINGH
M/s Rajkumar Mahto
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_256781.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .