| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.9 LAccepted-AOC | L1 | Accepted-AOC lowest bid quoted | |
| 2 | L2₹29.3 L+₹3.5 L (13.5%)Rejected-Finance | L2 | Rejected-Finance Highest bid quoted | |
| 3 | L3₹32.4 L+₹6.5 L (25.3%)Rejected-Finance | L3 | Rejected-Finance Highest bid quoted | |
| 4 | L4₹33.7 L+₹7.9 L (30.6%)Rejected-Finance 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NEW DELHI | DELHI | DELHI | 110006 | L4 | Rejected-Finance Highest bid quoted | |
| 5 | Rejected-Technical | - | Rejected-Technical Rejected due to fresh enlistment letter |
Tender Value
₹45.0 L
EMD Value
₹90,000
Closing Date
16 Jul 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Gurgaon
Gurgaon
REPAIR REPLACEMENT OF LT DISTRIBUTION SYSTEM AT DIFFERENT POWER HOUSES ALONGWITH CONNECTED ITEMS AT AIR FORCE STATION GURGAON UNDER AGE EM AF GURGAON OF GE AF GURGAON
2021_MES_452756_1
CA NO GE/GUR-/NIT-19/2021-22
Open Tender
Miscellaneous Works
Piece-work
240 days
GE (AF) Gurgaon
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) Gurgaon
₹90,000
23 Aug 2021
18 Jun 2021
19 Jul 2021
18 Jun 2021
16 Jul 2021
2 Jul 2021
60 days
Amount
Supply, installing, testing and commissioning factory made and tested LT Outdoor type, platform mounted, suitable for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system having bus bar chamber with insulated electrolytic Aluminium bus bars TPN of capacity 2400 Amps rating installed on DMC insulators with bus bar chamber. The panel shall be dust and vermin proof, and made out of 3.15 mm thick CRCA mild steel sheet and mild steel & Mounting channel frame work made out of 75 mm ), front opening type with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FRLS cable of adequate size but not less than 1.5 sqmm complete. All steel metal works including frame shall be with anticorrosive coating with seven tank process and finally epoxy polyester powder coating of Siemens grey RAL- 7035 shade. The scope of work also comprising of the following:- Make of Panel: Adlec/ Schneider / Universal Switch Gear Control/ Tricolite.
The panel manufacturer should have following Govt. Approved Certificates: 1. CPRI Certification Degree of Protection IP-54 2. CPRI Short Circuit withstand strenght should be 50kArms for 1.0 Sec with intial peak of 105kA 3. CPRI Certification Rated current for short circuit not less than 4000 A with rated insulation voltage 660V 4. ISO 9001 CERTIFIED
Supply, installing, testing and commissioning factory made and tested LT Outdoor type, platform mounted, suitable for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system having bus bar chamber with insulated electrolytic Aluminium bus bars TPN of capacity 500 Amps rating installed on DMC insulators with bus bar chamber. The panel shall be dust and vermin proof, and made out of 3.15 mm thick CRCA mild steel sheet and mild steel & Angle iron frame work made out of 50 mm x 50 mm X 6 mm ), front opening type with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FRLS cable of adequate size but not less than 1.5 sqmm complete. All steel metal works including frame shall be with anticorrosive coating with seven tank process and finally epoxy polyester powder coating of Siemens grey RAL- 7035 shade. The scope of work also comprising of the following:- Make of Panel: Adlec/ Schneider / Universal Switch Gear Control/ Tricolite. Note for item 1 to 4 : Rates are deemed to be included in quoted rates for suitable size PCC platform in 1:2:4 type B1 including plasterinity & fasterness complete all as directed
The panel manufacturer should have following Govt. Approved Certificates: 1. CPRI Certification Degree of Protection IP-54 2. CPRI Short Circuit withstand strenght should be 50kArms for 1.0 Sec with intial peak of 105kA 3. CPRI Certification Rated current for short circuit not less than 4000 A with rated insulation voltage 660V 4. ISO 9001 CERTIFIED
Supply, installing, testing and commissioning factory made and tested LT Panel Indoor type of size 1800 X 550 X 1700 mm ( LxWxH ), platform mounted, suitable for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system having bus bar chamber with insulated electrolytic Aluminium bus bars TPN of capacity 1000 Amps rating installed on DMC insulators with bus bar chamber. The panel shall be dust and vermin proof, and made out of 2.00 mm thick CRCA mild steel sheet and mild steel & Angle frame work of 50 X 50 X 6 mm ), front opening type with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FRLS cable of adequate size but not less than 1.5 sqmm complete. All steel metal works including frame shall be with anticorrosive coating with seven tank process and finally epoxy polyester powder coating of Siemens grey RAL- 7035 shade. The scope of work also comprising of the following:- Make of Panel: Unilac/ Schneider / Universal Switch Gear Control/ Tricolite. ( LOCATION :- )
The panel manufacturer should have following Govt. Approved Certificates: 1. CPRI Certification Degree of Protection IP-54 2. CPRI Short Circuit withstand strenght should be 50kArms for 1.0 Sec with intial peak of 105kA 3. CPRI Certification Rated current for short circuit not less than 4000 A with rated insulation voltage 660V 4. ISO 9001 CERTIFIED
Supply, installing, testing and commissioning factory made and tested LT Panel Feeder Pillar Outdoor type, platform mounted, suitable for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system. Shall be dust and vermin proof, protection class (IP-42) and made of 3.15 mm thick CRCA SHEET & suitable frame work/ support made out of 40 x 40 x 5 mm Aluminium, front opening type with space for cable entry from back side of the panel, with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FRLS cable of adequate size but not less than 1.5 sqmm complete. The scope of work also comprising of the following:- ( Location:-) Make:- Havells/ Schneider / ABB/ L&T/ Universal Switch Gear Control/ Tricolite.
BUS BAR CHAMBER :- (a) 600 Amp 3 Strips & Neutral Strip 300 Amp, Aluminium conductor, with color coded heat shrinkable sleave and shall be mounted on non hygroscopic, non combustible, track resistant, high strength DMC material, interconnection of all incomings & outgoings. INSTRUMENT CHAMBER :- (i) Digital Multi Function Meter with LED display for measurement of Voltage, current, frequency, Power Factor, 96 X 96 mm, 3 Phase - 01 Set. (ii) C.T's 400/5 A CL 1.0 Tape Wound- 01 Set. (Set of three) (iii) Red,Yellow,Green Phase indicating Lights LED type 220V AC- 1 Set. (Set of three). (iv) Protection MCB 6 A SP C Series- 1 Set. (Set of three). Make of Metering Accessories :-L&T/ AE/ Trinity/ Schneider. INCOMING SUPPLY :- (i) MCCB 400 Amps 50 KA , 4 Pole with Fixed thermal & magnetic release 415 volts , 50Hz,=01 No., OUTGOING SUPPLY :- (i) MCCB 315 Amps 36 KA , 4 Pole with Fixed thermal & magnetic release 415 volts , 50Hz,=01 No., (i) MCCB 160 Amps 25 KA , 4 Pole with Fixed thermal & magnetic release 415 volts , 50Hz,=01 No., (iii) Provision for Space = 1 No. Make of MCCB:- L&T/ Siemens/ Legrand/ABB.
The panel manufacturer should have following Govt. Approved Certificates: 1. CPRI Certification Degree of Protection IP-54 2. CPRI Short Circuit withstand strenght should be 50kArms for 1.0 Sec with intial peak of 105kA 3. CPRI Certification Rated current for short circuit not less than 4000 A with rated insulation voltage 660V 4. ISO 9001 CERTIFIED
Isolate/de-energize the supply to the LT Panel Board of capacity ranging from 200 Amps to 2000 Amps and voltage 415 Volts/230 Volts, opening the doors/covers of the cubicle enclosure for carrying out the servicing/maintenance/repairs of the Panel Board, switch gear, metering etc and re-fixing the same in place after repairs including testing and commissioning of the paenl board comprising of the following:- a) Cleaning the inside switch gear chambers for removing dust, carbon and rusted surfaces including cleaning with blower and apply insulating varnish. b) Check the condition of the DMC/SMC support insulators including cleaning applying Dr beck red for better IR values and replacement of insulators if required. c) Tightening up of all bus bar connections, cable connections, replace bolt, nuts wherever required. Note : Contractor has to inspect the site before quoting. Any modifications/frame work and renewal is deemed to be included in the quoted rates. Spares will be measured and paid under relevant items of schedule
S&F in repair mild steel hinges suitable for LT panel board shutters incl welding, riveting complete all as specified and as directed.
Disconnecting and taking down existing bus bars 4 wire system from LT panel board cleaning with CTC applying with becktol solution, removing old insulation and providing new heat shrink insulating sleeves, connecting and fixing in the same panel with new nuts, bolts, washers of suitable size complete all as specified and directed.
Disconnecting and taking out old existing worn out control wiring connections incl cable lugs of LT panel board of 4 wire system and supply and connect with new cable PVC insulated, stranded copper conductor 2.5 sqmm incl new copper lugs and nuts, bolts, washers complete all as specified and directed.
Disconnecting and taking out old existing worn out cable lugs, nuts, bolts, washers etc from LT panel board of 4 wire system (incomming and outgoing) and supply and connect with new aluminium lugs and nuts, bolts, washers etc complete all as specified and directed.
Taking out old existing worn out neoprene gasket from shutters of LT panel board single door /double doors or openable on both sides and supply and fix new neoprene gasket complete all as specified and directed.
Excavation in trenches n exc 1.5 wide and n exc 1.5 m in depth for foundation etc or for laying cable etc n exc 10 Sqm on plan and n exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and as directed.
Returning filling in including spreading, leveling, watering and well ramming in layers exc 25 cm thick complete all as specified and as directed.
Removal of excavated material/surplus soil to a distance n exc 50m and depositing where directed at a level n exc 50m above the starting point complete all as specified and as directed.
Supply and filling river sand in trenches including spreading for cushioning of LT UG cable complete all as specified and as dirceted. Note : Punned down thickness shall be measured and paid .
M&L for sub class ‘B’ bricks old size laid flat dry in trenches over cable, across the direction of cable complete all as specified & directed .
Supply, laying and testing in replacement of cable XLPE insulated screened, PVC bedded galvanized steel strip or wire armoured electric power cable (heavy duty) with aluminium conductor 1100 Volts grade cross sectional area 3.5 core x 300 Sq mm. complete all as directed. Note : Provision of suitable double crimpped lugs and glands shall deemed to be included in quoted rates.
.-Ditto- all as per item No 16 described here in before but 3.5 core 240 sqmm
Ditto all as per item No 16 described here in before but 3.5 core 185 sqmm
Ditto all as per item No 16 described here in before but 3.5 core 120 sqmm
Ditto all as per item No 16 described here in before but 3.5 core 95 sqmm
Ditto all as per item No 16 described here in before but 3.5 core 70 sqmm
Ditto all as per item No 16 described here in before but 3.5 core 50 sqmm
Ditto all as per item No 16 described here in before but 4 core 25 sqmm
Ditto all as per item No 16 described here in before but 4 core 16 sqmm
Material and Labour for disconnection of LT Electric supply by taking proper shut down and removing old UNSV LT Fidder Pillar retrieved from existing location vide Ser item No 1 to 4 complete all as spfd and directed by Engr-in-Charge.
S&F MCCB 400 A ,4 pole ,36 KA with adjustable thermal & fixed magnetic setting with bus bar spreader links for connecting both incoming and outgoing cables with suitable connections with suitable size of glands etc complete including testing & commissioning all as directed as per existing model/make.
M & L for Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6.0mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including using galvanised iron strip 32×6mm as earthing strip by means of bolts, nuts, check nuts and washers of galvanized iron or steel, earth plate surrounded by packed layer of char coal dust and common salt, 15cm thick all around bottom and top and watering pipe 20mm bore of GI light grade with funnel, wire mesh and 40 mm dia GI protection pipe medium grade all as shown in electrical plate No 3 of SSR Part-I and connected to earthing test point, main switch board and testing on completion including excavation, earth work concrete pit with 80mm thick RCC cover in RCC 1:2:4 type B-1 duly reinforced with MS bars 8mm dia @ 150C/C both ways and pit chamber in PCC 1:2:4 type B-1 with 2 Nos suitable lifting handles of 12mm MS bar complete all as specified.
Supply and lay in trenches GI strip 25 mm x 4 mm galvanised iron strip for earth continuity earthing all as specified and directed
M&L for Boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure complete all as directed.
Supply and lay in trenches /under roads/ crossing or fixed to wall/ pole, GI tubing light grade of size 40mm bore for protection of UG cables complete all as directed.
Ditto all as per item No 30 described here in before but 80 mm
M&L for defect rectification high tension or LT cable laid in trenches by locating fault with the help of electronic fault locating machine comprising of surge generator pulse, ECHO fault locator with high frequency distance calculator etc. including and additional excavation in normal alluvial strata required for exposing the cable fault ; removal of deteriorated portion of cable treating of cable and keeping the same ready for jointing work for cable of size up to 185 Sq mm three core. The fault locating equipments shall be brought to site within the hours of instruction from Engr-in-Charge as directed
S&F in repairs/removing the UG cable for rectification of faults after fault detection excavating the area and Crimping with suitable ferrules/lugs or any other misc items providing suitable insulation tape and relaying complete after rectification of faults complete all as specified and as directed. Note: (i) Excavated area shall be made good to original finish and no extra payment shall be done on this account. The items like Lugs, Ferrules, nuts, bolts if any shall deemed to be included in the rates quoted and no extra payment shall be done on this account. (ii) Item No 32 & 33 shall be attended immediately on intimtion by phone or SMS failing which an amount of Rs 5000/- per day after 2 days shall be recovered as penality.
Supply and Fix in replacement of security Light for use on top of the watch tower cabin with motorised system: 400 W HPSV high intensity, long range, weather & dust proof motor operated Security Search light with highly polished stainless steel reflector-cum-body, suitable heat sinks, toughened front glass, retaining ring, M.S. Cradle and passivated bolts. The search light would be supplied with 230 V ,400 Watt HPSV Lamps with control gear in cast alumiminum housing, The search light fitting would be suitable for installing on the roof of the watch tower cabin. The search light would be swiveling type & have both vertical & horizontal operational controls with the help of remote control unit with suitable control cables complete all as specified and directed. Make:Kalin/Dragon/Superoptics sale.
Supply, fixing and erection steel tubular swaged pole type 410SP-31(9 Mtr long) Swan neck complete with CI base plate,taper plug,bolts,nuts,and screws etc duly painted internally and externally with metal oxide anti corrosive paint before errection and painting with two coats aluminium paint after erection complete all as cofirming to IS 2713 (part-1 to 111) and complete all as specified and as directed. Note : Necessary earth work and concrete shall be measured and paid separately
M&L for Foundation for Tubular swaged pole type including excavation , getting out, pole foundation with PCC (1:4:8) type D 2 (using with 40 mm graded crushed stone aggregate). Coping of pole with PCC (11:3:6) type C ( using with 20 mm graded stone agregate) and removing surplus soil to a distance n.exc 50 m and making good surface complete all as specified and as directed
Supply and jointing in replacement of heat shrinkable straight through joint suitable for LT 1100 volts XLPE cable of size120 to 185 sqmm 3.5 core complete all as specified and as directed
Supply and jointing in replacement of heat shrinkable straight through joint suitable for LT 1100 volts XLPE cable of size 70 to 95 Sqmm 3.5 core complete all as specified and as directed
Supply and jointing in replacement of heat shrinkable straight through joint suitable for LT 1100 volts XLPE cable of size 25 to 50 Sqmm 3.5 core complete all as specified and as directed
Taking down old UNSV fidder pillar and Supply, fixing, testing and commissioning in replacement of feeder pillar panel single door floor mounted and wall/pole mounted outdoor type, as per IP-55 grade, made out of MS sheet 3.15 mm thick of size 540x525x200mm with aluminium bus bar 250 Amps, 4 strip (3 phase) complete drilled, insulated with colour coded insulation tape, mounted on insulators etc with RYB indicator, panel should be dust proof, vermin proof, powder coated , locking should be screw type, mechanical type, inter locking with 150 Amps 25 KA MCCB four pole for incomer cable, should have danger notice for 415 volts, AC, mounted on 50x50x6 mm angle iron frame having minimum 2 feet ground clearance duly embedded in and including PCC block (1:2:4) complete including termination of all incoming and outgoing cables with suitable size thimbles/lugs and glands etc and providing fixing arrangements including earthing lead fixing arrangement, complete all as directed. Note :- Installation, testing, commissioning and connecting of incoming and outgoing cable connection LT feeder pillar panel shall included in rates quoted.
S&F vertical type load line distribution board, double door, 4 way AC, 3 phase 415 volts, TPN bus bar 200 Amps rating and earth bus and din rail including 01 No. MCCB 3/4 pole 415 volts, 50 Hz, 100Amps 16 KA breaking capacity as incomer complete .
S&F in replacement of MCCB 4 pole, 415 volts, adjustable type 63 Amps with breaking capacity 16 KA and connecting testing with MCCB complete all as specified and as directed.
S&F in replacement of MCCB 4 pole, 415 volts, adjustable type 100 Amps with breaking capacity 16 KA and connecting testing with MCCB complete all as specified and as directed.
Supply and fix in replacement of MCB SP 6-32 Amps 230 volts 'B' series complete all as specified and as directed.
Supply and fix in replacement of MCB SPN 40-63 Amps 230 volts 'B' series complete all as specified and as directed.
M&L submain wiring with unsheathed multi-stranded FR Grade copper conductor cable 1100 volts grade drawn through in and including PVC rigid conduit medium grade of not less than 25mm dia with conduit accessories and concealed in wall/surface of ceiling for two runs of 6 Sqmm single core HR Grade and one run of 4 Sqmm PVC insulated copper conductor for earth continuity wire between main DB to Sub main DB complete all as specified and as directed. Note :- (i) Two run of single core cable with one run of earth continuity conductor and PVC conduit and accessories will be measured as one length including cutting chasing in wall complete. Note (ii): Rates shall deemed to be included for chases of conduit and sunking for boxes cutting and making holes in wall/floor for passing in or through conduit.
S&F in replacement of Solar panel for Intergrated Solar Street light 30 watt LED all in one luman/watt>125,Solar charge controller MPPT, Solar PV Module (wp) flow, Battery 12.8V 36AH, Back up 02 days with Li-ion battery with kit with hardware, connector & panel for installation of street light with Pole, with suitable dia for street light fitting with all fixing arrangements like nuts, bolts, clamps, PCC foundation etc complete all as directed Note: Earth work & PCC foundation is included in quoted rate. Make :- (Model No LHSTAKU7CBAF030 of Havells or equivalent in Halonix/Crompton)
M&L for painting of steel tubular pole including cable protection pipe and all iron parts of 9 mtr long pole complete with 2 coats of aluminium paint after cleaning all rust and dust and preparing surface with wire brush and including strips of white and red colour of synthetic enamel paint up to the height of 1.5 mtr from the bottom of the pole complete all as directed. Make : Nerolac/Asian paint
S&F MCCB 250 A ,3 pole ,25 KA with adjustable thermal & fixed magnetic setting with bus bar spreader links for connecting both incoming and outgoing cables with suitable connections with suitable size of glands etc complete including testing & commissioning all as specified and as directed
S&F MCCB 200 A ,3 pole ,25 KA with adjustable thermal & fixed magnetic setting with bus bar spreader links for connecting both incoming and outgoing cables with suitable connections with suitable size of glands etc complete including testing & commissioning all as specified and as directed
Supply and fixing weather proof street light junction box of size 300 x 200 x 105mm including MCB SP 6 Amps and connecting terminals 4 way and fixing with street light poles using necessary MS clamps, nuts, bolts washers, lugs for incoming and out going cables, gland for cable etc of suitable size complete all as specified and as directed. Make : Hensel/Sintex/Universal Switch Gear control Note : The rates quoted shall inclusive of provision and fixing of suitable lugs and glands for cable connection.
Material and labour for PVC flat twin core 2.5 sq mm aluminium wire 1100 volt grade laid in 20 mm dia medium grade rigid PVC conduit (and fixing brackets on PCC pole) from Loop-in-loop out junction box to light fitting terminal complete all as specified and as directed. Note :- PVC conduit shall be clamped properly with suitable clamps and no extra payment shall be done on this account.
S&F street light liminaree high power LED of 72 watt rating with unique lens to ensure to uniform distribution complete all as spcd as directed Cat Part No LSTP-72-CDL Make of CG or its equvalent Havells/Hallonix Note :- Rent for hydra is included in rates quoted by the contractor. All fixing material inculdied in the unit rate.
Supply only aluminium thimble heavy duty ISI mark suitable for 25 sqmm 3.5 core cable all as spfd & directed by Engr-in-Charge
.-do-all as item 54 above but 35sqmm x 3.5 core cable
.-do-all as item 54 above but 50sqmm x 3.5 core cable
.-do-all as item 54 above but 70sqmm x 3.5 core cable
.-do-all as item 54 above but 95sqmm x 3.5 core cable
.-do-all as item 54 above but 120sqmm x 3.5 core cable
.-do-all as item 54 above but 150sqmm x 3.5 core cable
.-do-all as item 54 above but 185sqmm x 3.5 core cable
.-do-all as item 54 above but 240sqmm x 3.5 core cable
.-do-all as item 54 above but 300sqmm x 3.5 core cable
D P ENTERPRISES
J B Electricals
Commercial Traders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .