Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.7 LAdmitted-Finance | ₹11.7 L | L1 | Admitted-Finance |
| 2 | L2₹15.4 L+₹3.7 L (31.5%)Admitted-Finance 57 B FEEDER ROAD GROUND FLOOR 57 B FEEDER ROAD BARRACKPORE NORTH 24 PARGANAS WEST BENGAL 700120 | 24 PARAGANAS NORTH | WEST BENGAL | 700120 | ₹15.4 L+₹3.7 L (31.5%) | L2 | Admitted-Finance |
| 3 | L3₹17.7 L+₹6.0 L (51.1%)Admitted-Finance | ₹17.7 L+₹6.0 L (51.1%) | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | ALPHA GAMMA AIR SOLUTIONS PVT. LTD. L2 | FRAISTEK IDEACS L3 | MP Entreprise L1 |
|---|---|---|---|---|---|---|
| 1.00Supply, Installation, testing and commissioning including vaccumization and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for Split AC system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : Note: Wall opening and making good to the damages. | ||||||
| 1.01 | 6.4 mm (¼") dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation | 305 | Rmt | 207 ₹63,135 Lowest | 238 ₹72,590 | 320 ₹97,600 |
| 1.02 | 9.5 mm (⅜")dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation | 455 | Rmt | 346 ₹1,57,430 | 400 ₹1,82,000 | 340 ₹1,54,700 Lowest |
| 1.03 | 12.7 mm (½") dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation | 305 | Rmt | 416 ₹1,26,880 | 402 ₹1,22,610 | 320 ₹97,600 Lowest |
| 1.04 | 15.86 mm ( ⅝") dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation | 305 | Rmt | 514 ₹1,56,770 | 605 ₹1,84,525 | 420 ₹1,28,100 Lowest |
| 1.05 | 19 mm (¾")dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation | 150 | Rmt | 10 ₹1,500 Lowest | 100 ₹15,000 | 520 ₹78,000 |
| 2.00 | Interconnection electrical Copper cables from Indoor , Outdoor & electrical control panel complete with 4 core 2.5 sqmm copper FRLS insulated cable(ISI marked) with cable tie & clamp etc as required. | 1,500 | Rft | 175 ₹2,62,500 | 250 ₹3,75,000 | 46 ₹69,000 Lowest |
| 3.00 | Supply & installation M.S epoxy painted fabricated stand for different size condensing unit with vibration isolators, grouting, for complete platform type stand for outdoor unit having safety railing etc as per site requirement. | 80 | Nos | 600 ₹48,000 | 415 ₹33,200 Lowest | 750 ₹60,000 |
| 4.00 | Supply & installation of UPVC drain pipe (ISI marked) with 6mm thick nitrile rubber insulation from IDU - 25mm dia | 1,500 | Rft | 100 ₹1,50,000 | 90 ₹1,35,000 | 70 ₹1,05,000 Lowest |
| 5.00 | 40 mm Rigid UPVC drain pipe (ISI marked) with 6 mm thick nitrile rubber insulation complete with fittings, U traps etc. & as specified to the nearest toilet with required civil works & finishing the same. | 200 | Rft | 125 ₹25,000 | 150 ₹30,000 | 100 ₹20,000 Lowest |
Tender Value
₹13.0 L
EMD Value
₹26,000
Closing Date
19 Jan 2026, 12:00 pmClosed
Superintending Engineer (E and M)
RAC Unit,1st Floor, Old Building, IIT Kharagpur, Kharagpur WB 721302
SITC of extra material for installation of unitary ACs in different Departments /Centers/Schools, office etc. at IIT Kharagpur, Kharagpur (Phase I).
2026_IITKG_892372_1
IIT/IW/RAC/TC/03/2025-26
Open Tender
Electrical Works
Item Rate
365 days
Kharagpur
Please refer Tender documents.
7 documents required · 7 mandatory
₹0
₹26,000
Meeting Room of SE (E and M)
6 Feb 2026
2 Jan 2026
20 Jan 2026
2 Jan 2026
19 Jan 2026
2 Jan 2026
8 Jan 2026
Supply, Installation, testing and commissioning including vaccumization and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for Split AC system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : Note: Wall opening and making good to the damages.
6.4 mm (¼") dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation
9.5 mm (⅜")dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation
12.7 mm (½") dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation
15.86 mm ( ⅝") dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation
19 mm (¾")dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation
Interconnection electrical Copper cables from Indoor , Outdoor & electrical control panel complete with 4 core 2.5 sqmm copper FRLS insulated cable(ISI marked) with cable tie & clamp etc as required.
Supply & installation M.S epoxy painted fabricated stand for different size condensing unit with vibration isolators, grouting, for complete platform type stand for outdoor unit having safety railing etc as per site requirement.
Supply & installation of UPVC drain pipe (ISI marked) with 6mm thick nitrile rubber insulation from IDU - 25mm dia
40 mm Rigid UPVC drain pipe (ISI marked) with 6 mm thick nitrile rubber insulation complete with fittings, U traps etc. & as specified to the nearest toilet with required civil works & finishing the same.
Supply of R-22 Gas for Top Up
Supply of R-32 Gas for Top Up
Supply & installation of good quality wooden frame (2" x 2") thick required for window ac installation
Supply & installation of 16amps Plug top (ISI marked)
Supply & installation of 100mm PVC Trunking with snap on trunking (ISI marked)
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray with cover (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.
100 mm width X 50 mm depth X 1.6 mm thickness
225 mm width X 50 mm depth X 1.6 mm thickness
300 mm width X 50 mm depth X 1.6 mm thickness
Installation, testing & commissioning of the window ,split acs ,Cassette Ac supplied by department. Price shall be inclusive of installtion upto 3mtr of refrigerant pipe, drain pipe and cable.
Window Acs
Split Acs
Cassette Acs
Tower Acs
Reinstallation, Lifting, Shifting of existing AC units (Split & window Acs & Cassette Ac).
Window Acs
Split Acs
Cassette Acs
Tower Acs
Dismantling of Existing AC (Split AC / Window AC) units including all copper pipes, drain pipes mounting surfaces, etc. complete and keeping the premises clear of all and shifting to RAC work shop
Dismantling of Existing AC (Cassette AC) units including all copper pipes, drain pipes mounting surfaces, etc. complete and keeping the premises clear of all and shifting to RAC work shop
Dismantling of Existing AC (Tower AC) units including all copper pipes, drain pipes mounting surfaces, etc. complete and keeping the premises clear of all and shifting to RAC work shop
Buy-back of existing unserviceable AC (Split AC / Window AC/Cassette AC) units(all type) including all copper pipes, drain pipes mounting surfaces, etc. complete. The item shall be quoted as negative item
Window Acs
Split Acs
cassette Acs
Decorative Pelmets of required size for IDUs with 16 mm thick anti termite laminated board.
Window AC 0.75 / 1 / 1.5 / 2 Tonne GI drain tray
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.85 MB
BOQ_937959.xls
BOQ • 0.40 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .