Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.1 LAdmitted-Finance | L1 | Admitted-Finance | |
| 2 | L2₹31.0 L+₹3.9 L (14.2%)Admitted-Finance | L2 | Admitted-Finance | |
| 3 | L3₹34.7 L+₹7.6 L (27.9%)Admitted-Finance | L3 | Admitted-Finance | |
| 4 | L4₹35.6 L+₹8.5 L (31.3%)Admitted-Finance WZ 1000 NANGAL RAYA PANKHA ROAD SOUTH WEST DELHI DELHI 110046 | DELHI | SOUTH WEST DELHI | DELHI | 110046 | L4 | Admitted-Finance | |
| 5 | L5₹37.0 L+₹9.9 L (36.4%)Admitted-Finance NO 9 BYRAVESHWARA INDUSTRIAL ESTATE ANDRAHALLI MAIN ROAD NEAR PEENYA 2ND STAGE BENGALURU 560 091 | BENGALURU URBAN | KARNATAKA | 560091 | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Vijay Electricals L5 | MV Engineers And Contractors L6 | Rajindera Enterprises L3 | mayur enterprises L4 | M/s JAIMAA ASSOCIATES L2 | Microsys Controls India L7 | INDIAN CONSTRUCTION CO. L1 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches not exc. 1.5 m wide and not exc 1.5 mtr deep in soft loose soil for laying / taking up/ taking down of cables and getting out and levelling of bottom suface to required level all as specified and directed by Engineer- in- Charge. | 1,600 | Cum | 9 ₹14,400 Lowest | 89 ₹1,42,400 | 40 ₹64,000 | 50 ₹80,000 | 35 ₹56,000 | 80 ₹1,28,000 | 49 ₹78,400 |
| 2.00 | Returning filling in,. Including spreading, levelling,. Watering and well ramming soil in layers not exceeding 25 cm thick all as specified and directed. | 1,034 | Cum | 9 ₹9,306 Lowest | 16 ₹16,544 | 9 ₹9,306 Lowest | 10 ₹10,340 | 10 ₹10,340 | 20 ₹20,680 | 9 ₹9,306 Lowest |
| 3.00 | Removing excavated material (ie soil) from site to a distance n. exc 50 mtrs away and depositing where directed at a level n. exc. 1.5 mtr above the starting point all as specified and directed by Engineer-in-Charge. | 566 | Cum | 9 ₹5,094 Lowest | 16 ₹9,056 | 9 ₹5,094 Lowest | 10 ₹5,660 | 10 ₹5,660 | 20 ₹11,320 | 9 ₹5,094 Lowest |
| 4.00 | Material and labour for river washed and screened, dry sand for filling in trenches below and around underground cables for cushioning of cables etc, complete all as specified. | 480 | Cum | 150 ₹72,000 | 180 ₹86,400 | 100 ₹48,000 | 110 ₹52,800 | 80 ₹38,400 | 280 ₹1,34,400 | 9 ₹4,320 Lowest |
| 5.00 | S&F sub class B bricks having minimum compressive strength 75 Kg/ Sqcm laid in trenches for cable protection etc complete all as directed by Engineer-in-Charge. | 44,000 | Each | 2 ₹88,000 | 2 ₹88,000 | 2 ₹88,000 | 1.5 ₹66,000 | 1 ₹44,000 | 3 ₹1,32,000 | 0.09 ₹3,960 Lowest |
| 6.00 | All as per srl item No 5 here-in-before but using old bricks obtained under srl item No 1 here in before. | 5,000 | Each | 0.5 ₹2,500 | 0.5 ₹2,500 | 0.1 ₹500 | 0.2 ₹1,000 | 0.2 ₹1,000 | 0.3 ₹1,500 | 0.09 ₹450 Lowest |
| 7.00Supplying, laying, jointing testing and connecting in replacement XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with multistranded aluminum conductors, IS 7098 marked, suitable for LT 1100 Volt system, laid in trenches fixed to pole, including jointing & testing complete all as specified and directed of following sizes:- Note :- Excavation, earth work ,cable protection , sand fillings , cable joint shall be measured and paid separately under respective items of schedule. | ||||||||||
| 7.01 | 16 Sqmm 4 core | 1,500 | RM | 89 ₹1,33,500 | 81 ₹1,21,500 | 55 ₹82,500 | 60 ₹90,000 | 45 ₹67,500 Lowest | 79 ₹1,18,500 | 59 ₹88,500 |
| 7.02 | 25 Sqmm 3.5 core | 1,500 | RM | 110 ₹1,65,000 | 89 ₹1,33,500 | 75 ₹1,12,500 | 75 ₹1,12,500 | 69 ₹1,03,500 Lowest | 99 ₹1,48,500 | 99 ₹1,48,500 |
| 7.03 | 35 Sq mm 3.5 core. | 500 | RM | 125 ₹62,500 | 131 ₹65,500 | 95 ₹47,500 | 110 ₹55,000 | 75 ₹37,500 Lowest | 119 ₹59,500 | 129 ₹64,500 |
Tender Value
Refer Docs
EMD Value
₹1 L
Closing Date
21 Nov 2020, 6:00 pmClosed
MR ARJUN PATRO
GE U ELECTRIC SUPPLY DELHI CANTT-10
Repair and maintenance of of LT cable LT poles and connected items at 4 No P F Station Road Maude Road Church Road Cassel Road Manekshaw Enclave Manekshaw Centre Mall Road Polo Road Tigris Road Mandir Marg Harbaksh Stadium Parade Road Parade Camp DG
2020_MES_365072_3
GE ELECT/D-68/2020-2021
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE U ELECTRIC SUPPLY DELHI CANTT
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE U ELECTRIC SUPPLY
₹1 L
Yes
23 Nov 2020
7 Nov 2020
23 Nov 2020
8 Nov 2020
21 Nov 2020
9 Nov 2020
Amount
Excavation in trenches not exc. 1.5 m wide and not exc 1.5 mtr deep in soft loose soil for laying / taking up/ taking down of cables and getting out and levelling of bottom suface to required level all as specified and directed by Engineer- in- Charge.
Returning filling in,. Including spreading, levelling,. Watering and well ramming soil in layers not exceeding 25 cm thick all as specified and directed.
Removing excavated material (ie soil) from site to a distance n. exc 50 mtrs away and depositing where directed at a level n. exc. 1.5 mtr above the starting point all as specified and directed by Engineer-in-Charge.
Material and labour for river washed and screened, dry sand for filling in trenches below and around underground cables for cushioning of cables etc, complete all as specified.
S&F sub class B bricks having minimum compressive strength 75 Kg/ Sqcm laid in trenches for cable protection etc complete all as directed by Engineer-in-Charge.
All as per srl item No 5 here-in-before but using old bricks obtained under srl item No 1 here in before.
Supplying, laying, jointing testing and connecting in replacement XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with multistranded aluminum conductors, IS 7098 marked, suitable for LT 1100 Volt system, laid in trenches fixed to pole, including jointing & testing complete all as specified and directed of following sizes:- Note :- Excavation, earth work ,cable protection , sand fillings , cable joint shall be measured and paid separately under respective items of schedule.
16 Sqmm 4 core
25 Sqmm 3.5 core
35 Sq mm 3.5 core.
50 Sq mm 3.5 core.
70 Sqmm 3.5 core
95 Sqmm 3.5 core
120 Sqmm 3.5 core
185 Sqmm 3.5 core
240 Sqmm 3.5 core
300 Sqmm 3.5 core
400 Sqmm single core
630 sqmm single core
Boring of hole under road/pavement/hard standing or any other situation by mannual means and suitable for passing of GI pipe 40 to 100 mm bore and making good both ends all specified and directed
S&F in replacement GI Pipe (light grade) with necessary accessories/ fittings for cable protections/pole for crossing of culverts/nallah of following bore sizes
Taking out faulty underground 1100 Volt LT cable of different sizes by excavation and removing bricks of any size and relaying in the same trenches or re routing after rectification of fault or replacing faulty portion of cable with new cable and removing of surplus soil and using new bricks as required. Note: (a) 1100 Volt LT cable & joints shall be measured and paid for seperately under respective items of schedule. (b) Retrieved old serviceable bricks will be laid in trenches for cable protection. If extra bricks and sand required at site shall be measured and paid separately under respective items of BOQs. (c) Excavation and earth work will be measured and paid for seperately under respective items of schedule.
Supply, fixing and testing straight through joint heat shrinkable type with jointing kit suitable for cable PVC/XLPE insulated armoured heavy duty aluminium conductor 1100 Volts grade complete all as directed for the following sizes :-
25-50 Sqmm x 3.5 core/ 4 core
70-150 Sqmm x 3.5 core
185 -240 Sqmm x 3.5 core
Taking down unservicable RCC/ steel tubular poles of any type and supply & installing steel tubular swaged poles type 410 SP-31 (9 mtr long) of approx wt.147 kg conforming to IS 2713 (Part-II) including excavation, earth work, PCC foundation, base plate,PCC coping,GI pipe for cable protection etc. and GI bracket for fitting mounting, complete all as per manufacturer's instructions and as specified and as directed by E-in-charge. NOTE:- The unit rate in this item is deemed to be included the cost of exacavation and earth work in any type of soil,PCC foundation 1:4:8 type D-2 , PCC coping 1:2:4 type B-1 as in steel tubular pole and GI bracket made of GI pipe medium grade 40 mm bore, 1.5 mtr long for fixing of street light fitings . The steel pole shall be painted by bituminious paint total length inside and up to planting depth outside and remaining portion of pole painted with two coat of aluminium paint over a coat of red oxide complete all as specified and directed.
Earthing in replacement complete with galvanized steel earth plate electrode of size 60cmx60cmx6 mm thick, buried directly in ground (earth pit not less than 2.1 m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level, connected to galvanized lead wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel as shown in electrical plate No 5 of SSR Part I, connected to earth test point and the equipment on the other nuts and washers of galvanised ironside complete all as specified, including testing and commissioning complete all as directed. Note : (a) The unit rates quoted against this item shall be deemed to include the cost of excavation and earth work in any type of soil, common salt & charcoal dust in alternate layers, PCC 1:3:6 as in pit, precast RCC 1:2:4 type B-1 with necessary reinforcement as in cover & frame for pit, funnel, watering pipe 20 mm bore GI pipe light grade, protection pipe 15 mm bore GI pipe light grade etc. (b) The quoted rates shall also deemed to include the cost of earth test point and earth strip/GI lead wire and protection pipe upto 7.5 meter beyond the earth plates electrode.
Supply & Fix in replacement Transparent KIOSK box weather proof incluiding made out of one piece mounted SMC base and door pole mounted hinged door size 333x233x120 mm out side and 300x200x105 mm inside dimensions comprising of aluminium bus bar 4 strip for 3 phase and neutral 63 Amps and incluiding embossing/ painting of danger notice of size not less than 10cm x 7.5 cm with letters,figures band conventional skull and bones in signal red colour on front face of KIOSK box body complete all as specified and directed.
S&F in replacement KIOSK box wheather proof including made out of one piece mounted SMC base and door pole mounted hinged door size 333x233x120mm out side and 300x200x105mm inside dimensions comprising of aluminium bus bar 4 strips for 3 phase and neutral 63 Amps including embossing/painting of danger notice of size not less than 10cm x 7.5cm with letters, figures and conventional skull and bones in signal red colour on front face of KIOSK box body complete all as specified and directed.Incluiding MS clamp of size 25x3 mm with suitable size nut,bolts & washer.
M&L for re-painting of LT Panels/feeder pillars of approx size 2 to 4 Sqm with 2 coats of super enamal paint over a coat of red-oxide with sparygun including writing of feeder pillar numbers in appropriate size of letters as directed.
All as per item No 16 above but of approx size upto 1.90 Sqm
M&L for re-painting of LT Steel tubular poles of any sizes with apply of 2 coats of aluminium paint including rubbing with wire brush/emery paper & writing pole Nos in appropriate size of letters including making yellow and black strips upto height of 1.5 mtr above from ground level complete all as specified and directed.
Earthing in replacement complete with galvanized steel earth plate electrode of size 60cmx60cmx6 mm thick, buried directly in ground (earth pit not less than 2.10 m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level, connected to galvanized iron strip 32mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel as shown in electrical plate No 3 of SSR Part I, connected to earth test point and the equipment on the other nuts and washers of galvanised ironside complete all as specified, including testing and commissioning complete all as directed. Note : (a) The unit rates quoted against this item shall be deemed to include the cost of excavation and earth work in any type of soil, common salt & charcoal dust in alternate layers, PCC 1:3:6 as in pit, precast RCC 1:2:4 type B-1 with necessary reinforcement as in cover & frame for pit, funnel, watering pipe 20 mm bore GI pipe light grade, protection pipe 40 mm bore GI pipe medium grade etc. (b) The quoted rates shall also deemed to include the cost of earth test point and earth strip/GI lead wire and protection pipe upto 7.5 meter beyond the earth plates electrode.
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 11 0 mm dia suitable for 0.6 mpa working pressure
Taking down unservicable RCC/ steel tubular poles of any type and supply & installing of Ornamental Cast iron pole of total height 7 Mtr nominal above the foundation top level with 2 mtr long single arm designer bracket fabricated out of cast iron embellishment, joints, column ,sections etc reinforced internally with a pipe inside. The bottom column should have an integral inbuilt looping box with cover duly mounted with one No. MCB, SP, 10 Amp, one No. 32 Amp, 4 way heavy duty connector and earth stud etc complete etc as required. The pole and bracket shall be painted with polyurthane paint of approved colour finish complete all as per manufacturer's instructions and as specified and as directed by Engr-in-charge. Make : Bajaj/Philips/Schreder/Surya/Hi Lite luminairies Note:- Sketch of pole with bracket is attached in particulars specifications no 37 at serial page no. 108 of tender documents Note:- The unit rate in this item is deemed to be include the cost of exacavation and earth work of any type of soil incuding dismantling of PCC foundation of unserserviciable pole ,RCC for foundation 1:2:4 type B-1 approx size 0.6mx0.6mx1.0m for new pole including supply and erection of EN-grade foundation Bolt M20*600mm long complete. Foundation for new pole to be made as per manufacturer's recommendations and approved by GE.
Taking down unservicable RCC/ steel tubular poles of any type and supply & installing steel tubular swan neck pole type 410 SP-31 (9 mtr long) complete with mild steel base plate, finial taper plug, bolts, nuts and screws including two coats of aluminium painting over a coat of primer for exposed surfaces and two coats of bituminous black paint over a coat of primer to the surfaces in contact with concrete inclusing two runs of PVC insulated 1100V multi-stranded copper wire of size 2.5 Sqmm from the junction box to the fitting complete all as specified and directed. Note :- The unit rate in this item is deemed to be included the cost oif exacavation and earth work in any type of soil,PCC foundation 1:4:8 type D-2 , PCC coping 1:2:4 type B-1 as in steel tubular pole and GI bracket made of GI pipe medium grade 40 mm bore, 1.5 mtr long for fixing of street light fitings . The steel pole shall be painted by bituminious paint total lenth inside and up to planting depth outside
Trimming and cutting of tree branches coming across LT over head line clearing the line around 1.5m single/both sides and stacking of serviceable material and disposal of unserviceable material to a distance n.exc 50m and cleaning site complete all as directed. Note :(i) Length of span is 35 to 40 RM. (ii) Due care is to be given while trimming/cutting the tree branches that there should no damage to over head line conductor/pole. In case due to any negligence, damage is caused to be make good/renewal by the contractor from his own resources and nothing extra shall be admissible on this account
S&F in replacement of LT, 1100 volt grade separators suitable for two no O/H conductor on exiting LT o/H Line complete all as directed.
S&F in replacement of LT, 1100 volt grade separators suitable for four no O/H conductor on exiting LT o/H Line complete all as directed.
Taking down unservicable RCC/ steel tubular poles of any type and supply & installing octagonal street light poles of 8 mtr height with 150mm bottom dia and 75mm top dia made up of 3mm thick alongwith galvanised base plate of size 225mmx225mmx16mm suitable to with stand maximum wind speed of 169 Km/hr and for mounting , decorative double/single over hand bracket for street light fittings . The internal & external surface of pole shall be dip galvanised 65 microns (minimum) DFT complete all as specified and directed. NOTE:- The unit rate in this item is deemed to be included the cost dismantling of old one pole , exacavation and earth work in any type of soil,PCC foundation 1:4:8 type D-2 , PCC coping 1:2:4 type B-1 as in pole and GI bracket made of GI pipe medium grade 40 mm bore, 1.5 mtr long for fixing of street light fitings .
S&F of stranded aluminium conductor cable PVC sheathed unarmoured , 1100 Volts , flat twin core of following sizes:-
Supply and fixing in replacement suspension type street light fitting, made of spun aluminium housing, polycarbonate diffuser protector with IP 65 protection for optical compartment with 60 Watt LED system, CCT 5700K. Make - Bajaj (Borage)/Philips /Schreder/Surya
Supplying and fixing in replacement LED flood light fittings 200 Watt complete all as specified and directed by Engr-in-charge :-
Supply and fix in replacement MCCB 63 Amp, 4 pole , 25 KA, 50 Hz including MCCB sheet metal enclosure mounted on wall with fastner and suitable size of nut and bolts complete all as directed .
M&L for Bore earthig 150 mm dia buried by vertical boring machine, depth 50 mtr below ground level using earth electrode 50mm dia GI pipe medium grade duly drilled hole of 12mm dia, 115mm C/C on both side of the pipe including lowering in bore well upto the depth of 49 mtr and one mtr above the ground level. The pipe electrode should be filled around commericial salt charcoal dust, copper suphate and magnesium phosphate of 30 cm layer each upto the full length of pipe. The borewell should have 12 mtr of length 150mm dia MS pipe for protection of borewell. Welding of GI Strip 50mmx6mm on earth electrode GI Pipe 50mm dia upto 10mtr below ground level and 15 mtr from the bore well to test point gun metal and PCC foundation surrounding the borewell 60cmx60cmx30cm all as directed by Engr-in-charge. GI strip more than 25mtr will be measured and paid separately. Note :- Cost of gun metal test point deemed to be included in the quoted rate.
Note : contractor should procure and provide 50 % of the material as listed above within 15 days of the placing of work order and shall be verified by the Eng-in-charge
M/s JAIMAA ASSOCIATES
Rajindera Enterprises
mayur enterprises
Vijay Electricals
MV Engineers And Contractors
Microsys Controls India
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .