Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.3 LAccepted-Finance | L1 | Accepted-Finance BEING L1 | |
| 2 | L2₹32.3 L+₹7.0 L (27.6%)Accepted-Finance | L2 | Accepted-Finance NOT BEING L1 | |
| 3 | L3₹33.6 L+₹8.3 L (32.6%)Accepted-Finance | L3 | Accepted-Finance NOT BEING L1 | |
| 4 | L4₹33.9 L+₹8.5 L (33.7%)Accepted-Finance | L4 | Accepted-Finance NOT BEING L1 | |
| 5 | L5₹33.9 L+₹8.6 L (33.8%)Accepted-Finance | L5 | Accepted-Finance NOT BEING L1 |
| Sl No | Description | Qty | Unit | MUKTI ENTERPRISES L1 | MAHIMA CONSTRUCTION L6 | SHRI SULAI ELECTRICALS L3 | M/s.NIKI ENTERPRISES L5 | LOKMANYA ENTERPRISES L2 | United Enterprises L4 | ANIKET ENGINEERING L7 | Shree Sai Samarth Enterprises L8 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down carefully aluminium/copper point wiring (light,fan,socket power etc) on TW batten/PVC casing capping, surface steel/PVC conduit including all fitting/fixtures and making good disturbed surfaces of wall/floor/ceiling etc to match the adjoining surfaces. | 760 | Per Point | 20 ₹15,200 | 47 ₹35,720 | 47 ₹35,720 | 47 ₹35,720 | 45 ₹34,200 | 25 ₹19,000 | 10 ₹7,600 Lowest | 50 ₹38,000 |
| 2.00 | M&L for point wiring complete with two single core, PVC insulated, unsheathed, multi stranded bright annealed copper conductor FRLSHS cable, 1.5 Sq.mm 1100 Volts , FR grade drawn through and including heavy duty PVC casing and capping/PVC conduit as required site not less than 25 mm width/circmfrnace and accessories surface mounted on walls, ceilings etc. on & including PVC board with earth dolly arrangement with surface plate PVC box for mounting modular and regular switches, sockets, regulators etc and one run of 1.5 Sq.mm PVC insulated FRLSH, unsheathed, multistranded, copper conductor cable FR grade as earth wire and connected to common earth dully complete for the following :-
(a) One light point controlled by one switch. | 350 | Per point | 600 ₹2,10,000 | 712 ₹2,49,200 | 713 ₹2,49,550 | 720 ₹2,52,000 | 686 ₹2,40,100 | 737 ₹2,57,950 | 485 ₹1,69,750 Lowest | 750 ₹2,62,500 |
| 3.00 | (b) One fan point controlled by one switch. | 50 | Per point | 600 ₹30,000 | 712 ₹35,600 | 713 ₹35,650 | 720 ₹36,000 | 686 ₹34,300 | 763 ₹38,150 | 490 ₹24,500 Lowest | 740 ₹37,000 |
| 4.00 | (c) One bell point controlled by one push button. | 50 | Per point | 600 ₹30,000 | 826 ₹41,300 | 828 ₹41,400 | 835 ₹41,750 | 796 ₹39,800 | 847 ₹42,350 | 520 ₹26,000 Lowest | 750 ₹37,500 |
| 5.00 | (d) One 3 pin socket out let 5 Amps on Same board. | 100 | Per point | 200 ₹20,000 | 255 ₹25,500 | 256 ₹25,600 | 258 ₹25,800 | 246 ₹24,600 | 262 ₹26,200 | 160 ₹16,000 Lowest | 200 ₹20,000 |
| 6.00 | (e) One 3 pin socket out let 5 Amps on independent board. | 100 | Per point | 600 ₹60,000 | 826 ₹82,600 | 828 ₹82,800 | 835 ₹83,500 | 796 ₹79,600 | 853 ₹85,300 | 535 ₹53,500 Lowest | 768 ₹76,800 |
| 7.00 | Ditto- all as per Sl item No 02 above but with two runs of 2.5 Sq.mm cable and one run of 2.5 Sq.mm cable as earth wire for one 3 pin socket outlet/power point 15 Amps controlled by one switch. | 110 | Per point | 750 ₹82,500 | 1,054 ₹1,15,940 | 1,057 ₹1,16,270 | 1,066 ₹1,17,260 | 1,016 ₹1,11,760 | 1,113 ₹1,22,430 | 635 ₹69,850 Lowest | 950 ₹1,04,500 |
| 8.00 | M & L for submain wiring with two single core PVC insulated flexible copper conductor cable of sze 2x 4 sqmm FRLSH and one single core PVC insulated flexible copper conductor cable green colour of size 4 Sqmm FRLSH as earth lead in and including PVC conduit/casing and capping and making good the disturbed wall surfaces to match with existing specification for power circuit ACs all as required at site or directed by Engr-in- charge. Make of Wire : HPL/Havells/KEI | 700 | RM | 300 ₹2,10,000 | 287 ₹2,00,900 | 287 ₹2,00,900 | 290 ₹2,03,000 | 276 ₹1,93,200 | 268 ₹1,87,600 Lowest | 280 ₹1,96,000 | 300 ₹2,10,000 |
| 9.00 | All as per item Si No 8 but 6 Sq.mm cable and one run of 6 Sq.mm complete all as specified and directed. | 600 | RM | 400 ₹2,40,000 | 390 ₹2,34,000 | 391 ₹2,34,600 | 394 ₹2,36,400 | 376 ₹2,25,600 | 390 ₹2,34,000 | 360 ₹2,16,000 Lowest | 650 ₹3,90,000 |
| 10.00 | S&F in repairs switch paino 5 Amps flush type single pole suitable for 230 Volts Make: Anchor Roma | 300 | Each | 50 ₹15,000 | 30 ₹9,000 | 29 ₹8,700 | 29 ₹8,700 | 28 ₹8,400 Lowest | 31 ₹9,300 | 30 ₹9,000 | 40 ₹12,000 |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
3 Aug 2026, 6:00 pmClosed
GE AF OJHAR
GE AF OJHAR AIR FORCE STN OJHAR DIST NASHIK PIN 422221
REPAIR REPLACEMENT OF INTERNAL WIRING AND ELECTRIC FITTING FIXTURE EXHAUST FAN CEILING FANS, HANGER LIGHTS AND OTHER CONNECTED ITEMS IN TECH AREA AND ADMIN AREA AT AF STN DEOLALI
2026_MES_778119_1
8429/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE AF OJHAR
As per tender documents
8 documents required · 8 mandatory
₹500
GE AF OJHAR
₹60,000
Yes
6 Aug 2026
13 Jul 2026
5 Aug 2026
13 Jul 2026
3 Aug 2026
28 Jul 2026
13 Jul 2026 - 27 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Taking down carefully aluminium/copper point wiring (light,fan,socket power etc) on TW batten/PVC casing capping, surface steel/PVC conduit including all fitting/fixtures and making good disturbed surfaces of wall/floor/ceiling etc to match the adjoining surfaces. | 760 | Per Point | - | - |
| 2 | M&L for point wiring complete with two single core, PVC insulated, unsheathed, multi stranded bright annealed copper conductor FRLSHS cable, 1.5 Sq.mm 1100 Volts , FR grade drawn through and including heavy duty PVC casing and capping/PVC conduit as required site not less than 25 mm width/circmfrnace and accessories surface mounted on walls, ceilings etc. on & including PVC board with earth dolly arrangement with surface plate PVC box for mounting modular and regular switches, sockets, regulators etc and one run of 1.5 Sq.mm PVC insulated FRLSH, unsheathed, multistranded, copper conductor cable FR grade as earth wire and connected to common earth dully complete for the following :-
(a) One light point controlled by one switch. | 350 | Per point | - | - |
| 3 | (b) One fan point controlled by one switch. | 50 | Per point | - | - |
| 4 | (c) One bell point controlled by one push button. | 50 | Per point | - | - |
| 5 | (d) One 3 pin socket out let 5 Amps on Same board. | 100 | Per point | - | - |
| 6 | (e) One 3 pin socket out let 5 Amps on independent board. | 100 | Per point | - | - |
| 7 | Ditto- all as per Sl item No 02 above but with two runs of 2.5 Sq.mm cable and one run of 2.5 Sq.mm cable as earth wire for one 3 pin socket outlet/power point 15 Amps controlled by one switch. | 110 | Per point | - | - |
| 8 | M & L for submain wiring with two single core PVC insulated flexible copper conductor cable of sze 2x 4 sqmm FRLSH and one single core PVC insulated flexible copper conductor cable green colour of size 4 Sqmm FRLS as earth lead in and including PVC conduit/casing and capping and making good the disturbed wall surfaces to match with existing specification for power circuit ACs all as required at site or directed by Engr-in- charge. Make of Wire : HPL/Havells/KEI | 700 | RM | - | - |
| 9 | All as per item Si No 8 but 6 Sq.mm cable and one run of 4 Sq.mm complete all as specified and directed. | 600 | RM | - | - |
| 10 | S&F in repairs switch paino 5 Amps flush type single pole suitable for 230 Volts Make: Anchor Roma | 300 | Each | - | - |
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.29 MB
BOQ_871481.xls
BOQ • 1.33 MB
TENDER8429.pdf
Tender Documents • 0.80 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .