Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.4 LAccepted-AOC 1001 63 SHALIMAR GARDEN ISMAILGANJ NEAR INDIRA NAGAR SECTOR 08 CROSSING LUCKNOW 226016 | LUCKNOW | UTTAR PRADESH | 226016 | L1 | Accepted-AOC Being lowest tenderer | |
| 2 | L2₹24.5 L+₹1.3 L (5.61%)Rejected-Finance 53 13 A OUTER CIRCULAR ROAD KILPAUK GARDEN COLONY CHENNAI 600 010 | CHENNAI | CHENNAI | TAMIL NADU | 600010 | L2 | Rejected-Finance Being other than lowest tenderer |
Tender Value
Refer Docs
EMD Value
₹60,000
Closing Date
12 Sept 2020, 6:00 pmClosed
COL PUNEET JAIN
COMMANDER WORKS ENGINEERS CHENNAI PALLAVAN SALAI CHENNAI 600 002
87615E8 RPRS AND MAINT RO PLANT AND SUMMER APPLIANCES AT AF AND ARMY AREA UNDER GE AVADI
2020_MES_370129_1
87615E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AVADI, CHENNAI
AS PER NIT
7 documents required · 7 mandatory
₹500
Yes
GE AVADI, CHENNAI
₹60,000
Yes
23 Nov 2020
18 Aug 2020
17 Sept 2020
18 Aug 2020
12 Sept 2020
25 Aug 2020
18 Aug 2020 - 22 Aug 2020
Amount
RETENDER BOQ UPLOADED ON 18 AUG 2020
MISCELLANEOUS ELECTRICAL ITEMS
Taking down existing unserviceable point wiring and taken on credit and provision of point wiring on stone / brick masonry wall complete with two 1.50 sqmm single core PVC insulated 1100 volts grade unsheathed cable confirming to IS-694, 1977 with multistranded copper conductor, drawn through and including non-metalic rigid PVC conduit, conduit fittings and conduit accessories not less than 20 mm dia surface run on ceiling / walls and fixed with suitable clamps and including provision of one 1.5 sqmm PVC insulated single core multistranded copper conductor green in colour as earth continuity conductor and connected to common earth dolly, including pressed steel terminal boxes made out of 1.6 mm thick mild steel sheet, 60mm deep, concealed in walls, duly painted with two coats of anti-corrosive over a coat of red oxide zinc chrome primer and covered with bakelite hylam sheet cover 3mm thick fixed with cadmium plated screws for housing the switches, socket outlets, fan regulators etc., complete all as specified and as directed for for one 3 pin switch socket outlet, 5 Amps, on independent board complete all as specified and as directed.
Cost of terminal box and cutting chases for concealing pipes is deemed to be included in the item rates quoted for point wiring.
All as per Sl Item No.1(a) here-in-before but for point wiring with two 4.0 sqmm single core copper conductor multistranded cable and one 4.0 sqmm PVC insulated single core multistranded cable as earth continuity conductor green in colour for for one 3 pin switch socket outlet, 15 Amps, on independent board complete all as specified and as directed.
Cost of terminal box and cutting chases for concealing pipes is deemed to be included in the item rates quoted for point wiring.
Taking down the existing unserviceable metal clad two pin and earth plug with MCB and taken on credit and replacing with metal clad two pin and earth plug and MCBs, single pole and neutral with two pin and earth plug and socket complete one single pole MCB 32 Amps, 10 kA, "C" Curve, 240 V complete all as specified and as directed.
Taking down the existing unserviceable metal clad two pin and earth plug with MCB and taken on credit and replacing with metal clad two pin and earth plug and MCBs, single pole and neutral with two pin and earth plug and socket complete one single pole MCB 20 Amps, 10 kA, "C" Curve, 240 V complete all as specified and as directed.
Sheet metal enclosures with socket plug top and MCBs, single pole and neutral with two pin and earth plug and socket complete one single pole MCB 20 Amps, 10 kA, "C" Curve, 240 V as in repairs complete all as specified and as directed.
Taking down carefully unserviceable sub main wiring aluminium conductor cables any number of runs of any cross section complete, including removal of batten / conduit and separating the serviceable items for reuse, removal from site under Sch of credit and removal of unserviceable items out of site and making good the disturbed surfaces of walls, ceilings etc., complete all as specified and as directed.
Power / Sub-main wiring with PVC insulated unsheathed, 1100 volts, grade multistranded copper conductor, two runs of single core 6 sqmm conforming to IS-694, drawn through and including suitable dia rigid PVC conduit, conduit fittings and conduit accessories alongwith one run 6 sqmm PVC insulated single core multistranded copper conductor cable (green) as earth continuity conductor surface run on ceiling / walls and fixed with suitable clamps, screws etc., and connecting with terminal lugs complete all as specified and as directed.
(a) Two runs of 6 sqmm cable and one run of 6 sqmm cable and one run of conduit will be measured as one length.
(b) Cost of terminal box is deemed to be included in the item rates quoted for sub-main wiring / circuit wiring.
Taking down the existing unserviceable PVC insulated and sheathed flexible cable, copper conductor of size 3 core, 4 sqmm and taken on credit and replacing with new PVC insulated and PVC sheathed cable, copper conductor of size 3 core, 4 sqmm, 1100 volts grade complete all as specified and as directed.
Taking down the existing unserviceable PVC insulated and sheathed flexible cable, copper conductor of size 3 core, 2.5 sqmm and taken on credit and replacing with new PVC insulated and PVC sheathed cable, copper conductor of size 3 core, 2.5 sqmm, 1100 volts grade complete all as specified and as directed.
Preparing surfaces and writing letters such as SM No. & MES No. with black colour oil paint of 20mm width x 20mm height for each letter complete all as specified and as directed.
The rate quoted is deemed for the entire job of writing SM No. & MES No.
Gun metal, globe or gate valves, with iron wheel head screwed both ends for iron pipe and fixed of bore of pipe 20mm as in repairs complete all as specified and as directed.
MAINT OF SUMMER APPLIANCES AND RO PLANT
Taking down the existing window type AC, 1.5 ton / 2.0 ton capacity of any make / model from its position and cleaning the AC externally and servicing the AC including cleaning of condensor, filter, cooling coil base bottom and fins, oiling / greasing of fan motor, checking of electrical wiring, replacement of worn out and short circuited wires, terminal clips etc., ensure smooth functioning and re-install and reconnect the AC unit in its exising location after proper cleaning of the place and testing and commissioning complete all as specified and as directed.
Taking down the existing split type AC, 1.5 ton / 2.0 ton capacity of any make / model from its position and cleaning the AC externally and servicing the AC including cleaning of condensor, filter, cooling coil base bottom and fins, oiling / greasing of fan motor, checking of electrical wiring, replacement of worn out and short circuited wires, terminal clips etc., ensure smooth functioning and re-install and reconnect the AC unit in its exising locations after proper cleaning of the places and testing and commissioning complete all as specified and as directed.
Taking down existing window type AC unit, repairing of opening in wall of size 1000mm x 600mm including necessary plaster and masonry patchwork in cement mortar 1:3, for proper reinstallation of window type AC unit, including plywood work and replacment of old thermacole around the AC for air tight fitting complete all as specified and as directed.
Taking down existing window type AC unit and dismantling old unserviceable timber framework and provision of timber framework, wrought in IInd class hardwood of section 100mm x 60mm, size of opening 1000mm x 600mm, for proper reinstallation of window type AC unit, including painting the exposed wooden surfaces with two coat of synthetic enamel paint over a coat of pink primer and tarring the hidden surfaces after due preparation of surfaces, suitable holdfasts of mild steel FI, duly tarred and sanded complete all as specified and as directed.
Preparing surface by removing dust, tinkering work by removing dents etc, making good any holes by welding and brazing, applying metal putty wherever necessary and spray painting with one coat of synthetic enamel paint after due preparation of surfaces of base plate and fan motor base of window type AC, of any make / model complete all as specified and as directed.
Rewinding of blower motor having high and medium speed of window type AC, 1.5 ton / 2.0 ton capacity of any make / model with super enamelled copper winding of appropriate gauge and quality and insulated with varnish after removal of burnt out winding from slots with emery paper, including replacement of worn out bush, bearing, shaft metalling / grinding complete all as specified and as directed.
Rewinding of blower motor having high and medium speed of split type AC, 1.5 ton / 2.0 ton capacity of any make / model with super enamelled copper winding of appropriate gauge and quality and insulated with varnish after removal of burnt out winding from slots with emery paper, including replacement of worn out bush, bearing, shaft metalling / grinding complete all as specified and as directed.
Charging of window type AC, 1.5 ton / 2.0 ton capacity of any make / model with freon gas (R-22), after dehydration as per standard practice, including detection of leaks and arresting the same by welding / brazing complete all as specified and as directed.
Spares as required shall be measured and paid separately.
Charging of split type AC, 1.5 ton / 2.0 ton capacity of any make / model with freon gas (R-22 / R-32), after dehydration as per standard practice, including detection of leaks and arresting the same by welding / brazing complete all as specified and as directed.
Spares as required shall be measured and paid separately.
Taking down the existing unserviceable compressor sealed unit by disconnecting the incoming / out going refrigerant lines and taken on credit and replacing with new compressor sealed unit, reconnecting refrigerant lines, detection of leakage and arresting the same by welding / brazing, flushing vacuuming and charging with gas of required quantity, after dehydration as per standard practice, compressor suitable for window type AC, 1.5 ton capacity of any make / model complete all as specified and as directed.
Taking down the existing unserviceable compressor sealed unit by disconnecting the incoming / out going refrigerant lines and taken on credit and replacing with new compressor sealed unit, reconnecting refrigerant lines, detection of leakage and arresting the same by welding / brazing, flushing vacuuming and charging with gas of required quantity, after dehydration as per standard practice, compressor suitable for split type AC, 1.5 ton capacity of any make / model complete all as specified and as directed.
Taking down the existing unserviceable compressor sealed unit by disconnecting the incoming / out going refrigerant lines and taken on credit and replacing with new compressor sealed unit, reconnecting refrigerant lines, detection of leakage and arresting the same by welding / brazing, flushing vacuuming and charging with gas of required quantity, after dehydration as per standard practice, compressor suitable for inverter type split AC, 1.5 ton capacity of any make / model complete all as specified and as directed.
Renewal of insulation materials for copper tubing as required for air tight fitting, ensure smooth functioning and re-install and reconnect the AC unit in its exising locations after proper cleaning of the places and testing and commissioning for split type AC 1.5 ton capacity complete all as specified and as directed.
Taking down the existing unserviceable copper tubing of size 1/2 inch and taken on credit and replacing with new copper tubing of size 1/2 inch for refrigent gas suitable for split type AC of any make / model complete all as specified and as directed.
Taking down the existing unserviceable copper tubing of size 1/4 inch and taken on credit and replacing with new copper tubing of size 1/4 inch for refrigent gas suitable for split type AC of any make / model complete all as specified and as directed.
Taking down the existing unserviceable copper tubing of size 3/8 inch and taken on credit and replacing with new copper tubing of size 3/8 inch for refrigent gas suitable for split type AC of any make / model complete all as specified and as directed.
Taking down the existing unserviceable copper tubing of size 5/8 inch and taken on credit and replacing with new copper tubing of size 5/8 inch for refrigent gas suitable for split type AC of any make / model complete all as specified and as directed.
Sleeves for copper tubing any size for split type AC of any make / model as in repairs complete all as specified and as directed.
Spring hose drainout for outdoor unit of split type AC of any make / model as in repairs complete all as specified and as directed.
Taking down the existing unserviceable strainer and capillary tube and taken on credit and replacing with new strainer and capillary tube suitable for window / split type AC, 1.5 ton capacity of any make / model complete all as specified and as directed.
Taking down the existing unserviceable GI bracket including all accessories and taken on credit and replacing with new GI bracket including all accessories suitable to fix outdoor unit of split type AC, of any make / model complete all as specified and as directed.
Taking down the following existing spare parts and taken on credit and replacing with new spare parts suitable for window type / split type AC of any make / model complete all as specified and as directed.
(a) Condensor coil suitable for window type AC, 1.5 ton capacity.
(b) Evaporator coil suitable for window type AC, 1.5 ton capacity.
(c) Evaporator coil suitable for split type AC, 1.5 ton capacity.
(d) Running capacitor 36 Mfd.
(e) Running capacitor 50 Mfd.
(f) Starting capacitor 100-120 Mfd.
(g) Starting capacitor 80-100 Mfd.
(h) Starting relay 1622.
(j) Starting relay 1022.
(k) Overload protector 1622.
(l) Overload protector 1022.
(m) Running capacitor 4 Mfd.
(n) Thermostat switch.
(p) Condensor fan blade suitable for window type AC, 1.5 ton capacity.
(q) Blower for cooling coil suitable for window type AC, 1.5 ton capacity.
(r) Condensor fan blade suitable for split type AC, 1.5 ton capacity.
(s) Blower for cooling coil suitable for split type AC, 1.5 ton / 2.0 ton capacity.
(t) Blower motor double speed suitable for window type AC, 1.5 ton / 2.0 ton capacity.
(u) Evaporator motor double speed suitable for split type AC, 1.5 ton / 2.0 ton capacity.
(v) Condensor motor suitable for split type AC, 1.5 ton / 2.0 ton capacity.
(w) Remote control sensor and digital device complete set with remote suitable for split type AC, 1.5 ton / 2.0 ton capacity.
(x) PCB (mother board) suitable for split type AC, 1.5 ton / 2.0 ton capacity.
(y) Air filter suitable for window type AC, 1.5 ton capacity.
(z) Front grill suitable for window type AC, 1.5 ton capacity.
(aa) Oscillating motor / device to change direction of air flow suitable for split type AC, 1.5 ton / 2.0 ton capacity.
(ab) Magnetic coil suitable for split type AC, 1.5 ton / 2.0 ton capacity.
(ac) Remote control sensor and digital device complete set with remote suitable for inverter split type AC, 1.5 ton capacity.
Renewal with fabricated sheet metal upto to a height of 100mm from bottom of the refrigerator on all the sides and bottom with 2mm thick mild sheet and framework and spray painting with two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer after due preparation of surfaces to match the adjacent surfaces for refrigerator of capacity 300 lits to 320 lits complete all as specified and as directed.
Preparation of surface by removing dust, tinkering, applying metal putty wherever necessary and painting with two coats of synthetic enamel paint by spray painting of the following cooling appliances all as specified and as directed.
(a) Refrigerator of capacity 300 lits to 320 lits.
(b) Refrigerator of capacity 165 lits to 200 lits
(c) Deep freezer of capacity 300 lits to 320 lits.
Taking down the existing unserviceable compressor sealed unit by disconnecting the incoming / out going refrigerant lines and taken on credit and replacing with new compressor sealed unit, reconnecting refrigerant lines, detection of leakage and arresting the same by welding / brazing, flushing vacuuming and charging with gas of required quantity, after dehydration as per standard practice, compressor suitable for digital inverter refrigerator of any make / model and capacity 300 lits to 350 lits complete all as specified and as directed.
Taking down the existing unserviceable compressor sealed unit, including flushing and taken on credit and replacing with new compressor sealed unit, reconnecting refrigerant lines, detection of leakage and arresting the same by welding / brazing, flushing vacuuming and charging with gas of required quantity, after dehydration as per standard practice, compressor suitable for refrigerator capacity 165 lits to 200 lits of any make / model and complete all as specified and as directed.
Taking down the existing unserviceable compressor sealed unit, including flushing and taken on credit and replacing with new compressor sealed unit, reconnecting refrigerant lines, detection of leakage and arresting the same by welding / brazing, flushing vacuuming and charging with gas of required quantity, after dehydration as per standard practice, compressor suitable for refrigerator of capacity 300 lits to 320 lits of any make / model complete all as specified and as directed.
Taking down the existing unserviceable compressor sealed unit by disconnecting the incoming / out going refrigerant lines and taken on credit and replacing with new compressor sealed unit, reconnecting refrigerant lines, detection of leakage and arresting the same by welding / brazing, flushing vacuuming and charging with gas of required quantity, after dehydration as per standard practice, compressor suitable for deep freezer of capacity 306 lits of any make / model complete all as specified and as directed.
Taking down the existing unserviceable compressor sealed unit by disconnecting the incoming / out going refrigerant lines and taken on credit and replacing with new compressor sealed unit, reconnecting refrigerant lines, detection of leakage and arresting the same by welding / brazing, flushing vacuuming and charging with gas of required quantity, after dehydration as per standard practice, compressor suitable for deep freezer of capacity 300 lits / 320 lits of any make / model complete all as specified and as directed.
Cutting the suction / discharge tubes of the compressor line and flushing, vacuuming and charging of refrigerator / freezer of any make / model with refrigerant gas (R-12/R-404), after dehydration as per standard practice, including detection of leaks and arresting the same by welding / brazing complete all as specified and as directed.
Spares as required shall be measured and paid separately.
(a) Refrigerator of capacity 165 lits to 200 lits
(b) Refrigerator of capacity 300 lits to 320 lits.
(c) Deep freezer of capacity 300 lits to 320 lits.
Taking out the existing unserviceable digital electronic circuit board and taken on credit and replacing with new digital electronic circuit board suitable for digital inverter refrigerator of any make / model and capacity 300 lits / 350 lits complete all as specified and as directed.
Taking down the existing unserviceable strainer and capillary tube and taken on credit and replacing with new strainer and capillary tube suitable for refrigerator / deep freezer of capacity 165 lits to 320 lits of any make / model complete all as specified and as directed.
Taking down the following existing spare parts and taken on credit and replacing with new spare parts suitable for refrigerators of any make / model complete all as specified and as directed.
(a) Magnetic door gasket suitable for refrigerator of capacity 300 lits to 320 lits.
(b) Freezer (cooling coil) suitable for refrigerator of capacity 300 lits to 320 lits.
(c) Freezer door set suitable for refrigerator of capacity 300 lits to 320 lits.
(d) Thermostat switch with knob
(e) Relay box type suitable for refrigerator of capacity 165 lits to 320 lits.
(f) Relay open type suitable for refrigerator of capacity 165 lits to 320 lits.
(g) Timer switch suitable for refrigerator of capacity 165 lits to 320 lits.
(h) Bimetal suitable for refrigerator of capacity 165 lits to 320 lits.
(j) Heater suitable for refrigerator of capacity 165 lits to 320 lits.
(k) Blower motor suitable for refrigerator of capacity 165 lits to 320 lits.
(l) Running capacitor 4 Mfd suitable for refrigerator of capacity 165 lits to 320 lits.
(m) Door lock with key in duplicte suitable for refrigerator of capacity 165 lits to 320 lits.
(o) Pigmy lamp screw / pin type with holder suitable for refrigerator of capacity 165 lits to 320 lits.
(p) Ice box tray suitable for refrigerator of capacity 165 lits to 320 lits.
(q) Vegetable tray suitable for refrigerator of capacity 165 lits to 320 lits.
(r) Bottle tray suitable for refrigerator of capacity 165 lits to 320 lits.
(s) Shelves of inner panel suitable for refrigerator of capacity 165 lits to 320 lits.
Taking down the following existing spare parts and taken on credit and replacing with new spare parts suitable for freezers of any make / model complete all as specified and as directed.
(a) Relay with OLP suitable for freezer of capacity 300 lits to 320 lits.
(b) Thermostat switch suitable for freezer of capacity 300 lits to 320 lits.
(c) Condensing motor suitable for freezer of capacity 300 lits to 320 lits.
(d) Starting capacitor 40 Mfd to 60 Mfd suitable for freezer of capacity 300 lits to 320 lits.
(e) Running capacitor 4 Mfd suitable for freezer of capacity 300 lits to 320 lits.
(f) Deep freezer door hinges with spring, screw etc suitable for freezer of capacity 300 lits to 320 lits.
(g) Hard PVC stand suitable for freezer of capacity 300 lits to 320 lits.
(h) Door shelves suitable for freezer of capacity 300 lits to 320 lits.
Renewal with fabricated sheet metal of base where compressor and condensor are mounted alongwith legs by base plate of sheet metal 2mm thick of size 600mm x 600mm with frame of angle iron 25mm x 25mm x 6mm alround,x 20mm with legs of mild steel pipe 40mm dia, 150mm long with bottom sealed with MS sheet 2mm thick and spray painting with two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer after due preparation of surfaces for water coolers of capacity 120 lits / 150 lits complete all as specified and as directed.
Cleaning of tank and condensor unit, preparation of surface by removing dust, tinkering, applying metal putty wherever necessary and painting with two coats of synthetic enamel paint by spray painting entire unit of water coolers of capacity 120 lits / 150 lits all as specified and as directed.
Rewinding of condensor fan motor of water cooler 120 lits / 150 lits capacity of any make / model with super enamelled copper winding of appropriate gauge and quality, including replacement of worn out bush, bearing, base clamp with rubber "O" ring, shaft metalling / grinding complete all as specified and as directed.
Cutting the suction / discharge tubes of the compressor line and Flushing, vacuuming and charging of water cooler of any make / model with refrigerant gas, after dehydration as per standard practice, including detection of leaks and arresting the same by welding / brazing complete all as specified and as directed.
Spares as required shall be measured and paid separately.
(a) Water cooler of capacity 150 lits.
(b) Water cooler of capacity 120 lits.
Taking down the existing unserviceable compressor sealed unit by disconnecting the incoming / out going refrigerant lines and taken on credit and replacing with new compressor sealed unit, reconnecting refrigerant lines, detection of leakage and arresting the same by welding / brazing, flushing vacuuming and charging with gas of required quantity, after dehydration as per standard practice, compressor suitable for water cooler of capacity as given here-in-after of any make / model complete all as specified and as directed.
(a) Water cooler of capacity 150 lits.
(b) Water cooler of capacity 120 lits.
Taking down the existing unserviceable strainer and capillary tube and taken on credit and replacing with new strainer and capillary tube suitable for water cooler of any make / model complete all as specified and as directed.
Taking down the existing unserviceable short circuited wires and terminal clips and taken on credit and replacing with new wires and terminal clips suitable for water cooler of any make / model complete all as specified and as directed.
Taking down the existing unserviceable PVC hose as drain out pipe and taken on credit and replacing with new PVC hose pipe heavy duty 25mm dia drain out pipe for water cooler complete all as specified and as directed.
Taking down the existing unserviceable PVC hose as drain out pipe and taken on credit and replacing with new PVC hose pipe heavy duty 40mm dia drain out pipe for water cooler complete all as specified and as directed.
Taking down the existing unserviceable PVC water inlet pipe and taken on credit and replacing with new PVC pipe, transparent, heavy duty 20mm dia water inlet pipe for water cooler complete all as specified and as directed.
Taking down the existing unserviceable PVC pipe as drain out pipe and taken on credit and replacing with new PVC pipe, heavy duty 50mm dia drain out pipe laid on walls / floor for water cooler complete all as specified and as directed.
Taking down the existing unserviceable PVC pipe as drain out pipe and taken on credit and replacing with new PVC pipe, heavy duty 20mm dia drain out pipe laid on walls / floor for water cooler complete all as specified and as directed.
Taking down the following existing spare parts and taken on credit and replacing with new spare parts suitable for water coolers of capacity 120 lits / 150 lits of any make / model complete all as specified and as directed.
(a) Running capacitor 30 Mfd.
(b) Running capacitor 15 Mfd / 20 Mfd.
(c) Starting capacitor 60 Mfd to 80 Mfd.
(d) Starting capacitor 40 Mfd to 60 Mfd.
(e) Starting relay box type 1022.
(f) Starting relay 522.
(g) Starting relay 412.
(h) Overload protector 1022
(j) Overload protector 522
(k) Thermostat switch
(l) Float valve with ball of size 15mm.
(m) Push cock straight type nickel coated 15mm.
(n) Push cock angle type with round disc nickel coated 15mm.
(o) Plug top 3 pin 15 Amps
(p) Socket outlet 5 pin 5 / 5 Amps
(q) Rubber gasket for water cooler tank
(r) Door lock with key in duplicte suitable for water cooler tank
(s) PVC connections 15mm size with PTMT nuts of length 600mm complete all as specified and as directed.
(t) Condensor coil .
Taking down the following existing spare parts and taken on credit and replacing with new spare parts suitable for voltage stabilizers of capacity 9 kVA / 5 kVA of any make / model complete all as specified and as directed.
(a) Main transformer
(b) Sub transformer
(c) Transistorised electronic relay.
(d) Electronic PC circuit plate having diodes, condensers etc.,
(e) Voltmeter 0-300 Volts
(f) High / low voltage cut-off relay
(g) Time delay relay
(h) Output terminal contacts
(j) Socket outlet 5 pin 5 / 15 Amps
Disconnecting and dismantling of RO plant of capacity 250 LPH / 500 LPH etc.,and servicing / overhauling, cleaning of sand / carbon / micro filter / membrane filmtech, check water leakage in filters and pipe, re-installing, reconnecting, testing and commissioning for proper and smooth functioning complete all as specified and as directed
Spares as required shall be measured and paid separately.
Taking down the following existing spare parts and taken on credit and replacing with new spare parts suitable for RO plant of capacity 250 LPH / 500 LPH complete all as specified and as directed.
(a) Raw water pump 0.50 HP.
(b) Sand / carbon filter vessel 1054
(c) Sand bag 10 kg as 1 unit
(d) Fine Sand bag 10 kg as 1 unit
(e) Silex 10 kg as 1 unit
(g) Pebbles 10 kg as 1 unit
(h) Carbon bag 450 IV 10 kg as 1 unit
(j) Multiport valve 20 NB
(k) Dozing pump
(l) 20 inch housing filter
(m) 20 inch filter spun
(n) 20 inch wound
(o) Antiscalant liquid
(p) High pressure pump (CRI) 2-100
(q) 40-40 membrane housing
(r) End cup
(s) End cup "O" ring
(t) Saddles and straps
(u) Membrane (Filmtech), (hydro nautics)
(v) Membrane connecter
(w) Auto electric panel
(x) Flow meter 0-600
(y) Flow meter 0-1200
(z) Pressure gauge
(aa) UPVC pipe 20mm dia and accessories
(ab) Ball valve 1/4 inch
(ac) Ultra violet media 250 LPH
(ad) Clip for Ultra violet media
(ae) High pressure pump bolt
(af) 50 litre tank
(ag) Membrane cleaning liquid
(ah)Ball valve 1/2 inch
Disconnecting and dismantling of RO plant of capacity 15 LPH / 50 LPH etc.,and servicing / overhauling, cleaning of sand / carbon / micro filter / membrane filmtech, check water leakage in filters and pipe, re-installing, reconnecting, testing and commissioning for proper and smooth functioning complete all as specified and as directed
Spares as required shall be measured and paid separately.
Taking down the following existing spare parts and taken on credit and replacing with new spare parts suitable for RO plant of capacity 15 LPH / 50 LPH complete all as specified and as directed.
(a) Carbon granules filter
(b) 5-5 membrane and housing assembly 70 gallon per day.
(c) Pressure pump 48 V
(d) Adaptor 48 V
(e) Carbon black filter.
(f) Micron filter
Disconnecting, dismantling and removing of domestic water purifier with filters fixed on wall and connected to water coolers at various locations, servicing / overhauling, cleaning of filters, re-installing, reconnecting, testing and commissioning for proper and smooth functioning complete all as specified and as directed.
The minor spares and consumables as required are deemed to be included in rate quoted.
The model of the purifier required to serviced / overhauled shall be ascertained at site.
M/s.Sai Agency
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .