| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.6 LAccepted-AOC | L1 | Accepted-AOC Lowest tenderer | |
| 2 | L2₹48.6 L+₹2.9 L (6.39%)Rejected-Finance | L2 | Rejected-Finance Other than lowest tenderer | |
| 3 | L3₹50.7 L+₹5.0 L (11.0%)Rejected-Finance | L3 | Rejected-Finance Other than lowest tenderer | |
| 4 | L4₹53.7 L+₹8.1 L (17.7%)Rejected-Finance 261 BHARAT NAGAR BATHINDA PB 151001 | BATHINDA | BATHINDA | PUNJAB | 151001 | L4 | Rejected-Finance Other than lowest tenderer | |
| 5 | L5₹56.2 L+₹10.5 L (23.1%)Rejected-Finance | L5 | Rejected-Finance Other than lowest tenderer |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
4 Jan 2024, 6:00 pmClosed
Vipin Chandra Rai
GE UTILITY BATHINDA
REPAIR/ REPLACEMENT OF LT PANEL AND MISC ELECTRICAL WORKS AT DIFFERENT LOCATION UNDER GE (U) BATHINDA.
2023_MES_631361_1
8772/2023-24/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
Garrison Engineer Utility Bathinda
Class D cat b i
9 documents required · 9 mandatory
₹500
Garrison Engineer (U) Bathinda
₹1 L
Yes
26 Feb 2024
6 Dec 2023
6 Jan 2024
6 Dec 2023
4 Jan 2024
21 Dec 2023
Amount
Dismantling/Taking down existing unserviceable panel board of any size by disconnecting the existing cable connection, earthing complete all as directed. Note :- (i) The cost of necessary excavation and earthwork for LT UG cables of any size and type for taking out loop is included in the quoted rate.
Taking out old unserviceable / faulty cable /service connection cable of any grade / type / class of size of 10 Sq mm to 70 Sq mm 2 core /4 core to repair / replacement from pole / wall / cable duct under ground trench complete all as directed.
Supply and laying XLPE, LT Cable of size 10 Sqmm, 2 core, 1100 Volt grade heavy duty with XLPE insulated standard aluminium conductor served with an inner sheathening of PVC tape armoured with Galvanized steel wire and over all PVC Sheathed stranded conductor conforming to IS- 7098 (Part-I) with latest amendments laid in trenches/fixed to wall/pole/laid in floor including necessary connections and suitable size of thimbling complete all as specified and directed.
All as per item No 09 above but sectional area 16 Sqmm 4 core.
All as per item No 09 above but sectional area 50 Sqmm 4 core.
All as per item No 09 above but sectional area 70 Sqmm 3.5 core.
Laying only old serviceable XLPE insulated armoured heavy duty underground electric cable reterived of any size, laid in trenches/ ducts/ through pipes/ in floors / under roads/ hard standing /along poles complete all as directed.
Excavation in trenches not exceeding 1.5 metre wide and not exc 1.5 metre in depth for foundation of pole / stay, or cable trenches and getting out in soft/loose soil complete all as specified and directed.
Returning filling in including spreading, leveling watering and well ramming in layers not exceeding 25 cm in soft loose soil complete all as specified and directed.
Removing excavated materials to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 metre above the starting point all as specified and directed.
Supply and laying Best quality, locally available, sub class ‘B’ clay bricks (Old Size) for cable protection cover, laid flat and dry in trenches over the cable , perpendicular to the direction of cable complete all as specified and directed.
Material & labour sand cushioning using clean Fine River sand for underground cable 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cable complete all as specified and directed. ( Note:- Punned thickness shall be considered for payment purpose)
Supply and laying or fixing in repair GI tubing light grade 50 mm bore for cable protection including fitting with flat iron clamps size of flat iron 25 mm x 4 mm, nuts, bolts & washers fixed to poles / along wall / floor / under road / across the drain or nallah / laid in trench complete all as directed.
Supply and errect in repair steel tubular poles type 410 SP-31 (9.00 mtr long) with cast iron base plate, finial, taper plug, bolts nuts & screws including painting with bituminous paint internal surface of steel tubular pole through out and external surface up to planting depth and remaining external surface shall be treated with two coats of aluminium paint over a coat of red oxide zinc chromate primer and painting upto 1.5 mtr with alternate layer of yellow & black including marking Sr No of poles complete all as specified and directed. Note:- Necessary earthwork and cement concrete work shall be measured and paid seperately under respective items of BOQ.
Supply and fixing in repair LT Cable junction box , insulated and made out of Polycarbonate with glass fiber reinforced and size should not less then 260 mm x 210 mm x 116 mm. The Polycarbonate Junction Box shall be environment friendly, recyclabe, halogen & silicon free, anti acid & anti corrosive. The Junction Box shall be rated for Degree of ingress Protection IP 66 in accordance with IEC 60529. The gasket material of junction box shall be Polyurethane and the gasket shall be internally embedded.The Junction Box shall be complies with requirements of the standards IEC 60998 - 1, IEC 60670 - 22 & IEC 60670 - 2 - 5. The Junction Box colour according to RAL 9011. 7.The manufacturer of Junction Box / Enclosure shall submit a copy of IEC Certificate . For beter safety the Polycarbonate enclosure and shall be fire retardant & self - extinguishing in accordance with IEC 60695 - 2 - 11, DIN VDE 0304 Part - 3, UL Subject 94 for Flammability V-2. It should be tested at Glove Wire test for 960 degree Centigrade. The impact strength of Polycarbonate enclosure / boards i.e. the Degree of protection against mechnical load shall be in accordance with EN 50298 - 98 for IK 08 including one No. 4 pole connector and one no. MCB SP 'C' curved 6 Amp 9/10KA and chromium plated clamps and nut bolts complete all as per manufacturers instructions. Manufacturer should submit routine test certificate of CJB/PJB complete all as directed. Make : Hensel, Cat Part K 9350 /Siemens/GE Power/ Sintex. Note :- The cost of one No. 4 pole connector and one No. MCB SP 'C' curved 6 Amp 9/10KA and chromium plated clamps and nut bolts are included in the quoted rate of this item and nothing shall be paid extra on this account.
Supply and fixing in repair street light bracket made out of 40 mm dia GI tubing medium grade made to shape 1.5 Mtr long with fixing arrangement for LED fitting including MS clamps and back plates fabricated from steel section including nuts, bolts, washer and duly painted the MS clamps and back plates ,bolts, washer etc with two coats of synthetic enamel paint over a coat of primer complete all as specified and directed.
Material and Labour for PCC (1:3:6) type C2 using 40 mm graded crushed stone aggregate as in foundation of poles/struts including necessary form work complete all as specified and directed.
Material and Labour for PCC (1:2:4) type B1 using 20 mm graded crushed stone aggregate as in coping, foundation of poles/struts etc including necessary form work complete all as specified and directed. Note for serial item No. 23 and 24: Volume of poles / struts embedded in concrete shall be deducted for the purpose of payment.
Supply and fixing wall mounted LED Batten T-8 Retro LED 18/20 watt, appx 4 feet long, pre wired including LED tube light, not less than 6000K, integrated electronic driver complete fitting and all other accessories fitting arrangements including electric connection connecting with using flexible copper wire twin core upto ceiling rose/connector and including taking down of existing fitting complete all as specified and as directed.
Supply and fix in repair energy efficient LED street light fitting of 25 Watt capacity with toughened clear glass , LED chip efficacy > 130 lumen / watt, system efficacy > 120 lumen / watt, luminarie shall be mandatory brand embossed on luminaries, potted antivibration driver. The driver shall be able to withstand for indoor at 440V for 8 hours . The driver should have fascility and cut off voltage. Input over voltage protection will be > 300 Volt AC and for cut off the luminaires should withstand for 48 hours at 100 Volt AC. The LED efficacy shall be more than 85% at a junction temperature of 85 degree centigrade. All screws of the luminaires should be SS304. Luminaires pressure dicast aluminium housing with mendatory secondary optics, CCT: 5700K ANSIBIN, CRI > 70, LED source : 1-5 Watt high power type , driver of luminaire shall be preferably in separate compartment another optical compartment .The LED driver shall be constant current type fully potted. Driver shall be provided for all luminaires. It should be moiture resistant and fire reterdant. At least industrial grade or higher grade component should be used for manufacturing of driver. The driver shall be able to withstand surge (EFT+ESD interference) of minimum 4 KV. Luminaire shall have surge protection device of minimum 10 KV inside the driver compertment. The driver shall have under voltage, over voltage and short circuit protection and auto recovery mode. Total harmonic distortion shall be < 10% with power factor minimum 0.95. It should give consistent performance in the input voltage range of 120 V - 270 V at 50 Hz. Luminaires shall be mandatory brand embossed of luminaries and including all electric connection and accessories complete all as directed.
All as per serial item No. 26 above but for LED street light fitting of 60 Watt
M&L for post top lantern decorative oriental design landscape luminaire suitable for 1X40 watt LED lamp with opel diffuser including taking down the old existing unserviceable one complete all as directed.
Supply and fix in repair energy efficient LED flood light fitting of 150 Watt capacity with toughened clear glass , LED chip efficacy > 130 lumen / watt, system efficacy > 120 lumen / watt, luminarie shall be mandatory brand embossed on luminaries, potted antivibration driver. The driver shall be able to withstand for indoor at 440V for 8 hours . The driver should have fascility and cut off voltage. Input over voltage protection will be > 300 Volt AC and for cut off the luminaires should withstand for 48 hours at 100 Volt AC. The LED efficacy shall be more than 85% at a junction temperature of 85 degree centigrade. All screws of the luminaires should be SS304. Luminaires pressure dicast aluminium housing with mendatory secondary optics, CCT: 5700K ANSIBIN, CRI > 70, LED source : 1-5 Watt high power type , driver of luminaire shall be preferably in separate compartment another optical compartment .The LED driver shall be constant current type fully potted. Driver shall be provided for all luminaires. It should be moiture resistant and fire reterdant. At least industrial grade or higher grade component should be used for manufacturing of driver. The driver shall be able to withstand surge (EFT+ESD interference) of minimum 4 KV. Luminaire shall have surge protection device of minimum 10 KV inside the driver compertment. The driver shall have under voltage, over voltage and short circuit protection and auto recovery mode. Total harmonic distortion shall be < 10% with power factor minimum 0.95. It should give consistent performance in the input voltage range of 120 V - 270 V at 50 Hz. Luminaires shall be mandatory brand embossed of luminaries and including all electric connection and accessories complete all as directed.
All as per serial item No. 29 above but for LED flood light fitting of 60 Watt
Supply and fixing in repair fully automatic star delta starter with sheet metal enclosure 415 volts, 3 phase, 50 Hz with single phase protection feature and timer with relay range 45 to 75 Amp and contractors suitable for 60 HP electric motor including making electric connections complete all as specified and directed.
Supply and fixing in repair fully automatic star delta starter with sheet metal enclosure 415 volts, 3 phase, 50 Hz with single phase protection feature and timer with relay range 20 to 33 Amp and contractors suitable for 40 HP electric motor including making electric connections complete all as specified and directed.
Supply and fixing in repair DOL starter with sheet metal enclosure 415 volts, 3 phase, 50 Hz with relay range 9 to 15 Amp suitable for 10 HP electric motor including making electric connections complete all as specified and directed.
Supply and fixing in repair power contactor 415 volt, 50 HZ, 3 pole, type ML-6 complete all as specified and directed.
Supply and fixing in repair power contactor 415 volt, 50 cycles, 3 pole, type ML-4 complete all as specified and directed.
Supply and fixing in repair power contactor 415 volt, 50 HZ, 3 pole, type ML-3 complete all as specified and directed.
Supply and fixing in repair power contactor 415 volt, 50 cycles, 3 phase, type MNX 80 complete all as specified and directed.
Supply and fixing in repair power contactor 415 volt, 50 cycles, 3 phase, type MNX 70 complete all as specified and directed.
Supply and fixing in repair power contactor 415 volt, 50 cycles, 3 phase, type MNX 95 complete all as specified and directed.
Supply and fixing in repair power contactor 415 volt, 50 cycles, 3 phase, type MNX 110 complete all as specified and directed.
Supply and fixing in repair bimetal over load relay single phase protection directly mounted 28 to 42 Amps, range ML2/ML3 complete all as specified and directed.
Supply and fixing in repair bimetal over load relay single phase protection directly mounted 66 to 110 Amps, range MN5 complete all as specified and directed.
Supply and fixing in repair bimetal over load relay single phase protection directly mounted 45 to 75 Amps, range MN5 complete all as specified and directed.
Supply and fixing in repair electronic timer (time delay relay) of range 12-120 sec, input voltage 220 to 240 volts AC complete all as specified and directed.
Supply and fixing in repair single phase preventor, type VSP-2 suitable for 3 phase star delta starter of any capacity complete all as specified and directed.
Supply and fixing in repair MCCB, 250 Amp, 4 pole ,415 Volts, 50 cycle, breaking capacity 36 KA, thermal magnetic release complete all as specified and directed.
Supply and fixing in repair MCCB, 250 Amp, 3 pole ,415 Volts, 50 cycle, breaking capacity 36 KA, thermal magnetic release complete all as specified and directed.
Supply and fixing in repair MCCB, 125 Amp, 3 pole ,415 Volts, 50 cycle, breaking capacity 36 KA, thermal magnetic release complete all as specified and directed.
Supply and fixing in repair MCCB, 100 Amp, 3 pole ,415 Volts, 50 cycle, breaking capacity 36 KA, thermal magnetic release complete all as specified and directed.
Supply and fixing in repair MCCB, 63 Amp, 3 pole ,415 Volts, 50 cycle, breaking capacity 36 KA, thermal magnetic release complete all as specified and directed.
Supply and fixing in repair change over switch 200 Amps, 415 Volts, FP 50 HZ manually Operated complete all as specified and directed.
Supply and fixing in repair change over switch 400 Amps, 415 Volts, FP 50 HZ manually Operated complete all as specified and directed.
Supply and fixing in repair change over switch 630 Amps, 415 Volts,FP 50 HZ manually Operated complete all as specified and directed.
Supply and fixing in repair change over switch 800 Amps, 415 Volts,FP 50 HZ manually Operated complete all as specified and directed.
Preparation of the old painted surfaces of feeder piller boxes/panels/boards of any size any description and in any position including removal of faded & deteriorated paint eaither by hand scrapping or by blow lamps, applying necessary filler coat and scrspping as required and applying two coats of synthetic enamelled paint (grey in colour) by using spray machine on old prepared surfaces complete all as spcified and as directed.
Supply and fixing in repair MS sheet Water Level indicator for Overhead Tanks, board size 30 cm x 450 cm x 3 mm thick along with suitable support MS angle,Clamps,Iron Pulley,rope and float valve complete all as directed. Note:- (i) Level indicator board must be painted with two coats of Synthetic enemal Paint over a coat of red oxide primer and Levels should be marked and written on it as directed. (ii) Rate of Painting and Writing deemed to be included in the quoted rate. (iii) Rate of Scaffolding for execution of this item is deemed to be included in Quoted rate. (iv) Contractor will submit the labour insurence to Engineer in Charge before execution of this work and contractor will arrange all the sefty equipments required for execution of this work.
Supply and fixing in repair MS sheet Water Level indicator for Underground Sumps, board size 30 cm x4 50 cm x 3 mm thick along with suitable support MS angle,Clamps,Iron Pulley,rope and float valve complete all as directed. Note:- (i) Level indicator board must be painted with two coats of Synthetic enemal Paint over a coat of red oxide primer and Levels should be marked and written on it as directed. (ii) Rate of Painting and Writing deemed to be included in the quoted rate.
Supply and fixing in repair Flow meter of cast iron suitable for pipeline of dia 250 mm , Mechanical type, megnetic drive with flanged ends (flanged standards PN-16) complete all as directed.
Supply and fixing in repair Flow meter of cast iron suitable for pipeline of dia 200 mm , Mechanical type, megnetic drive with flanged ends(flanged standards PN-16) complete all as directed.
Supply and fixing in repair Compact motor protection relay - MM10 as specified and directed. Note:- The devise must have protection against Thermal Overload with pre-alarm , Short Circuit , Earth fault , Phase loss, unbalanced,phase reversal, under current,prolong starting and locked Rotor.
M&L for collection of water sample from different locations as directed by the Engineer-in-Charge in clean/sanitized bottle of capacity 01 Ltr in front of MES rep, carrying out the Bioligical and chemical analysis test from the govt approved laboratory and submiting the test result to Engineer-in-Charge for each sample complete all as directed.
Demolition of old earth pit and Material and Labour for Earthing complete with galvanised iron earth plate electrode of size 600mm x 600mm x 6mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including GI strip 32 mm X 6 mm by means of GI bolts/nuts/washers, protected by 40 mm bore GI light grade pipe. Earth plate shall be surrounded by alternate layer of charcoal or coke and common salt 15 cm thick all around bottom and top. 20 mm GI light grade pipe for watering and including funnel, wire mesh,RCC cover & frame, PCC (1:3:6) type C1 (using 20 mm graded crushed stone aggregate) as in earthing pit including necessary excavation & earth work, all as specified & shown in electrical plate No. 3 of SSR Part – I. Note:- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner.
M/s NIRMAN BUILDERS
MICKY CONSTRUCTION PVT LTD
Surindera Kumar Bansal
M/s Kataria Construction Company
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .