Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.1 LAccepted-AOC BARJORA BANKURA | BANKURA | BANKURA | WEST BENGAL | 722202 | L1 | Accepted-AOC L1 | |
| 2 | L2₹11.1 L+₹4,977.37 (0.45%)Rejected-Finance RAMPUR HAZRA LANE BANKURA W B | BANKURA | BANKURA | WEST BENGAL | L2 | Rejected-Finance L2 | |
| 3 | L3₹11.1 L+₹7,200.68 (0.65%)Rejected-Finance WEST BENGAL WB | DARJEELING | WEST BENGAL | 734008 | L3 | Rejected-Finance L3 |
Tender Value
₹11.1 L
EMD Value
₹22,500
Closing Date
13 May 2022, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EXECUTIVE ENGINEER DPMU BANKURA WBADMIP
ADMIN BUILDING WRIDD PRANABANANDA SARANI KENDUADIHI BANKURA 722102
Gopalpur Solar LDTW Mouza Gopalpur JL No 49 Plot no 535 Block Onda in the district of Bankura under Matir Shristi Project
2022_WRDD_375587_1
04/2022-23/ MS/ EE DPMU/ BANK
Open Tender
CIVIL WORKS
Item Rate
180 days
BANKURA
Please refer Tender documents.
4 documents required · 4 mandatory
₹22,500
Yes
26 Sept 2022
12 Apr 2022
17 May 2022
12 Apr 2022
13 May 2022
12 Apr 2022
180 days
Amount
Drilling of borehole by direct rotary rig through any kind of soil or rock down to required depth by using not more than 215 mm dia. drill bit including arrangement of water for the bore hole all complete.
(a) 0 mtr. to 120 mtr
Electrologging of bore hole of different dia tubewell for locating water bearing strata and saline aquifer, if any, after conducting relevant geophysical tests. All test reports, compiled data and raw data sheets should be submitted to the Engineer-in-Charge (Cost is inclusive of all charges for equipments, labour, data aquisition & compilation of data sheets as per direction of the Engineer-incharge)
Labour charges for fitting, fixing & jointing thread to thread with solvent cement the PVC. pipes (Housing pipe, Blank Pipes, Strainers, bottom plug etc.) and lowering the same carefully into the bore hole down to the required depth complete in all respects as per direction of the Engineer-in-charge
a) 150 mm DN dia. blank pipe, Bottom Plug & Screen/Slotted Pipe
b) 250 mm DN dia. Housing pipe
i)150 mm N.D. 7.5 mm thick UPVC(CM) pipes/ pipes , screwed on both ends, one end socketed and other end protected with plastic protector, dully ISI certification marked., as per IS: 12818 with latest amendments thereof. and threaded to match with GI pipes as per Is: 1239 (PART -1) with latest amendments as per approval of Engineer-in-charge.
Supplying PVC strainer of approved make with adapter conforming to I.S.12818 specifications. (v) 150 mm dia
(ii) M.S. Centre guide (consisting of 3 nos., not less than 450 mm long and 125 mm rise of arch) of approved quality with two nos. MS clamps suitable for PVC- U pipes.
Supplying, fitting and fixing including supplying of suitable jointing compound for fixing in position, threading, if necessary etc. all complete.
(b) ii) 100 mm. X 150 mm. M.S. heavy type belmouth reducing socket (6 mm. thick).
( c ) 150 mm dia. G.I. threaded top cap fixed in position.
(e) (ii) 100 x 150 mm UPVC readucing socket
Supply of gravel for use as packin tubewell of 2mm to 4mm. Size (as per IS:4097) and gravel treatment of tubewell including screening ,washing ,cleaning etc. of the gravels at the site, all complete as per direction of the Engineer-in-Charge
Washing and development by pumping with 30 cum per hour capacity pump for a period till sand free water comes out and the discharge is about 30 cum per hour, followed by final yield test; inclusive of all tools, plants and scaffolding and hire charge of submersible pump, generator etc. all complete
Hire charge of generators including accessories and operational personnels for aquifer parameter test including transporation, fuel, lubricant, electrical connections etc. complete ( 2 nos generators - one running & one stand by for uninterrupted power supply to be arranged for each site).
Hire charges of submersible pump sets of 100 cum/hr capacity, with column pipes, sluice valve, 900 bend, short piece, starter, mainswitch, cable etc. all complete as per instruction of Engineer-in-charge including testing equipments.
Labour charges for lowering the submersible pump set, column pipes with necessary accessories including fitting & fixing the same in the tubewell including proper electrical connection with generator all complete as per direction of Engineer-in-charge and also withdrawal of the same after completion of the test.
Collecting of sample of water for bacteriological & chemical test from any depth at any point of time during execution of works including hire & labour charges for tools and plants and sterilizing the equipments, paying all charges and fees towards testing by accredated Lab. etc. complete in all respects as per direction of the Engineer-in-charge.
(A) Sypply of E.R.W.M.S.(Electrical Resistant Welded M.S.) black pipe of TATA make (heavy quality) as per standard specification, 5 mm thick iv) 250 mm dia. (internal)
(iii) M.S.Top cap of suitable size (6mm thick) and approved quality for covering top of housing pipe of 250 mm NB (Top cap will be tack welded with housing pipe at 4 points 90° apart).
Installation of submersible electro motor pumping set of following capacities by using necessary requisite, tools and plants by lowering the same within the tubewell housing pipe upto the following depth as per direction by fitting, fixing column pipes and other accessories, fixtures with necessary nuts, bolts and washers and suspending the entire assembly of pump set vertically by fixing the same supported by M.S. clamps over the top of housing pipe, binding the motor cable with each column pipes and drawing cable upto pump controllerl starter point including opening out of the top cap of housing pipe of the tubewell and testing of motor both in loading as well as in unloaded condition before and after installation of the same. (The rate is inclusive of hiring charges of tools & plants.)
(b) 30 m3 per hour capacity electro motor pumping set.
(ii) Length of pump assembly of any length exceeding 18 metre length.
Supplying, fitting and fixing G.I. pipes of TATA make with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads, fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) (ii) 80 mm dia. medium quality
80 mm NB heavy duty suppoting clamps in two halves made of MS flats for holding column pipes
Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete.
(a) Depth of excavation not exceeding 1,500 mm.
Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work)
(a) With earth obtained from excavation of foundation
(A) Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity)
Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.
Brick work with 1st class bricks in cement mortar (1:4)
(a) In foundation and plinth
Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes.
(iv) With local hard blackstone variety chips (crusher broken)
125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor.
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface]
(ii) With 1:4 cement mortar (Outside)
(a) 20 mm thick plaster
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction.
(a) For works in foundation, basement and upto roof of ground floor/upto 4 m
(i) Tor steel/Mild Steel
I. SAIL/ TATA/RINL
(a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor.
(i) Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr.
(b) Extra for work in grill gate.
(I) For hanging and locking arrangements including supply of materials and labour complete.
Supplying 1.5mm thick M.S. sheet fitted and fixed on one or both faces of M.S./ W.I. gate etc. with point welding at not more than 150mm apart complete in all respect as per design including cost of all labour and materials.
(a) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.
A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary.
With other than hi-gloss of approved quality.
(iv) Two coats (with any shade except white)
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works
(a) 25 mm to 30 mm thick wooden shuttering as per decision & direction of Engineer-In- Charge.
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes.
d) With local hard blackstone variety chips (crusher broken)
Neat cement punning about 1.5mm thick in wall,dado,window sill,floor etc. NOTE: Cement 0.152 cu.m per 100 sq.m.
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured(matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as perdirection of the EIC.
In Ground Floor: (b) Two coat
Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of EIC to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer.
In Ground floor (Two Coat) a) Normal Acrylic Emulsion
Solar Module: Supply, transport, installation and commissioning of MNRE (Ministry of Renewable Energy,Govt. of India)/ IECapproved Solar Module of multicrystaline cell with min. efficiency of 15% and fill factor more than 70%, laminated between sheet of -Ethylene Vinyl Acetate (EVA)and high transmissivity 3.2 mm tempered glass, framed in anodized aluminium frame .The power output of individual PV modules used in the PV array, under STC,should be a minimum of 300 Watt peak,with adequate provision for measurement tolerances.Modules supplied with the Spy system should have certificate as per IEC61215 specification or equivalent National or International standards. Modules must qualify to IEC 61730 part I and part II for safety qualification testing and Salt Mist Corrosion Testingasper IEC61701/IS 61701 and having warranty for output wattage, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. Necessary test certificate also to be supplied. c) For 5 HP Off-grid Solar Water Pumping System with Monocrystalline / Monocrystalline PERC/bifacial spv modules -5600/5700 Wp. (Item No.1 Chapter 12,P-10)
Module Mounting Structure ( For 2HP, 3HP and 5HP Solar Water Pumping System): Supply , transportation & installation of G.I manual tracking structure made of MS hollow sections, pipes, plates, angles etc as per IS 1161/1239, 1079/2062, to hold min 300 Wp SPV Module as per drawing and specification of MNRE . The steel structure is to be protected with minimum 80 micron galvanisation(hot dip) and provided with dual axis manual tracking arrangement three times in a day and seasonal tilting are to be regulated to face the sun optimally. The weight of the Module Mounting Structure holding 4 Modules should not be less than 165 Kgs, holding 5/ 6 Modules should not be less than 235 Kg and holding 7/ 8 Modules should not be less than 265 Kg. (Item No.2 Chapter 12,P-10)
Foundation of Module Mounting Structure: Suitable and stable Reinforced Cement Concrete foundation for dual axis manual tracking Spy Module structure as per approved drawing. b) For 6 module structure having maximum capacity of 1950Wp
Powerconditioning unit including MPPT, Data logger and IP54enclosure: Supply , transport , installation and commissioning of IP S4 protected enclosured Inverter Unit qualifying IEC 61683-Efficiency measurement and IEC 600682-Environment Standard , safety standard suitable for 3 Phase A.C. motor, IGBT based high voltage switching inverter with MPPT technology,to take care of the variation of Sun light and will be suitably mounted inside the metal enclosure.Inverter should have protection againstDry run, Overcurrent, Under current, Overvoltage, Undervoltage, Short circuit etc. Systemshould be able to run at low sunshineand minimum 7 to 8 hours a day run should be possible during normal sunshinecondition. Inverter should have option to auto start for any short trip off due to low light/ cloudy situation exceptfor dry run. Inverter should 4 be providedwith a display to show the various parameter by the user suchasVoltage, Current, Solar panel DC voltage, Inverter IGBTtemperature, Out put AC voltage, Output frequency, Pump flow (direct or calculatedmethod), Irradiation etc. The system should be capable to store the data at a set Interval and transfer it in a pendrive through USB port. It should also monitor and save total run time, total water pumped etc. There should be provision for interfacing GPRS based data transmission c) For 5 HP capacity Pump-motor set (Item No.3 Chapter 12,P-11)
Cableand Accessories: Supplying,fitting and fixings of UV rated Copper Cablel aid inside HOPE conduit and other accessories as per followings with necessary connection with the Solar PV Module, MPPTetc. I. 4.0 Sq mm single core multi studs - 5 m ( for 2 HP) & 20m for 3/5 HP) II. Lugs,HOPE Pipe,Flexible Pipe,Saddle,Cabletie etc c) For 5 HP per structure (Item No.4 Chapter 12,P-11)
Earthing: Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWGGI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S& F 15 mm dia GI pipe protection (1 Mt. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an averagedepth of 3.65 Mts. below the ground level as below: By lSI-Medium GI pipe including excavation of soil for installation of Earth Electrode and filling & ramming and connecting to individual structure to earth electrode including S &F 20' mm x 3 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddlesas required and connection to equipments incl. drilling holes,with bolts, nuts, washers etc complete. (Item No.5 Chapter 12,P-11)
Lightning protection (Pole mounted): Lightning protection with 3" X1.5" G.I pipe of 4 mts height with base flange in proper RCC foundation and S & F Lightning Conductor Air Terminal made of 20 mm dia 1000 mm long GI pipe (lSI Medium) having five discharge prongs of 4 SWGGI (Hot Dip) wire at top duly soldered with 7/16 stranded GI(Hot Dip) wire and 85 mrn dia 6 mm thick GI base plate at bottom incl. necessary holes etc. Earthing with 65 mm dia GI pipe (Medium) 3.0 Mts. long and 1 x 19/10 stranded GI (Hot Dip) wire (4 Mts. long), 20 mm dia x 125 mm long galvanized bolt, double nuts, double washers including socketing at both ends of stranded GI (Hot Dip) wire by crimping sockets/thimbles and S & F 40 mm dia GI pipe (lSI-Medium) protection (3 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 Mts. (Provision of one lightning protection for each structure). (Item No.7a Chapter 12,P-12)
Supply and installation of 3 phase electro motor pump set suitable for Solar operation covering 5 years warranty for the following conditions including loading, unloading,transportation etc. c) iii) Submersible Pump-motor set for LDTW ISI marked as per IS:8034 with dischargeof 7.5 tps- 5.83 Lpsat 30 mts.-40 mts. total head with cable (3m), bends,cover plate, Socket,flanged, Nipple, Rubber Insertion, Nuts & bolts and all other accessories Including transportation of bend, column pipes,Sluic valve, lay flat hose pipe etc. from Deptt. Store to site within 100 k.m. (Item No.8 Chapter 12,P-13)
Testing and commissioning of scheme after completion of all work. (Item No.9 Chapter 12,P-13)
Comprehensive maintenance charges for 4 years beyond 1 year warranty period (which cover monthly inspection, Yearly training to WUA, to attend breakdown within 3 days and to keep the scheme in operation without lapse of time). c) For 5 HP both for Submersible & Surface pump. (Item No.10 Chapter 12,P-13)
Remote monitoring for 5 years: Supply & installation of GSM/ GPRS based Data Transmitter or Modem and to provide remote monitoring service to transmit the parameters to central server from the solar pumping system with time stamp at user defined interval and report generation at the buyer end. (Item No.11 Chapter 12,P-13)
Insurance @ 2% Item No. 1,4,7a/7b, and 9 for a period of 5 years. (Item No.12 Chapter 12,P-13)
Construction of display board
ABHIJIT MUKHERJEE
BISWESWAR CONSTRUCTION
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .