Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.3 CrAccepted-Finance | ₹4.3 Cr | L1 | Accepted-Finance L1 |
| 2 | L2₹4.4 Cr+₹1 L (0.23%)Rejected-Finance | ₹4.4 Cr+₹1 L (0.23%) | L2 | Rejected-Finance L2 |
Tender Value
Refer Docs
EMD Value
₹8.7 L
Closing Date
9 Jul 2022, 6:00 pmClosed
Execuitve Engineer
O/o Executive Engineer, Engg. Wing, Itanagar
Construction of Temporary Structure at Sainik School Niglok, East Siang District (SH Pre-fabricated Boys Hostel, Pre-fabricated Classroom, MI Room (Boys), Administration Block, Principal Quarter Type V).
2022_ARED_801_1
EDN(EW)/Plg-015/2021/45
Open Tender
Civil Works
Item Rate
540 days
Pasighat
Please refer Tender documents.
4 documents required · 4 mandatory
₹5,000
Yes
Payable To Executive Engineer
₹8.7 L
Yes
O/o Executive Engineer, Engg. Wing, Itanagar
2 Sept 2022
4 Jul 2022
11 Jul 2022
4 Jul 2022
9 Jul 2022
4 Jul 2022
7 Jul 2022
Amount
I) (SH:- Administrative Block Building) Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock), lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required, into plinth sides offoundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus soil as directed within a lead of 50m.
Filling in plinth with sand under floors including watering, ramming, consolidating and dressing complete.
Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering.
Providing and laying cement concrete 1 : 2 : 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering in : b) Walls including attached buttresses, pilasters and their caps and bases and string courses etc. up to floor two level.
Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcement in :a) 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement.
Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface.
Centring and shuttering including strutting, propping etc and removal of form work for : a) Foundation, footings, bases of columns etc. and mass concrete.
b) Column Pillars Struts.
c) Lintels, beams, girders, bressumers and cantilevers etc.
Reinforcement of RCC work including bending, binding and placing in position complete.a) Mild Steel
Brick work with best available local bricks in foundations and plinth in cement mortar 1:5 (1 cement : 5 fine sand).
Extra for brick work with best available local bricks in superstructure above plinth level up to floor two level.
Providing approved best available local wood (Class - B II) work in frames of doors, windows clerestory windows and other frames, wrought framed and fixed in position.
Providing best available local wood (Class - B II) work in frames of false ceiling, partitions and trusses etc, sawn and put up in position.
Providing and fixing panelled, glazed or panelled and glazed shutters for doors, windows and clerestory windows including necessary iron butt hinges with necessary screws. a) 38 mm thick best available local wood, class - B I
Providing and fixing 40 x 3 mm flat iron hold fasts 40 cm long including fixing to frame with 10 mm dia bolts, nuts and wooden plugs and embedding in cement concrete block 30 x 10 x 15 cm in 1 : 3 : 6 (1 cement : 3 sand : 6 hard stone chips 40 mm nominal
Providing and fixing MS grills of required pattern in wooden frames of windows etc with MS flat, square or round bars with round headed bolts and nuts or by screws.a) Ornamental Grill.
Providing and fixing aluminum butt hinges anodised, transparent or dyed to required color or shade with necessary screws etc complete. b) 100 x 63 x 4 mm
Providing and fixing aluminum Handles anodised transparent or dyed to required color or shade with necessary screws etc complete. a) 100 mm
Providing and fixing M.S. hooks and Eyes (a) 150 mm.
Providing and fixing MS fan clamp type I of 16 mm dia MS bar bent to shape with hooked ends in RCC slabs during lying including painting the exposed portion of loop all as per standard design complete.
Steel work in built up tubular trusses including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer welded and bolted including special shaped washers etc complete (welding to be paid separately).
Steel work in ralling including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer welded and bolted including special shaped washers etc complete (welding to be paid separately).
Welding by gas plant
Cement concrete flooring 1 : 2 : 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement. c) 75 mm thick
White glazed tiles 5mm.thick in flooring, skirting, risers of step and dado in 12 mm thick cement plaster 1 : 3(1 cement: 3 coarse sand) painted with white cement slurry.
12 mm cement plaster 1 : 5 (1 cement : 5 fine sand).
15 mm cement plaster 1 : 4 (1 cement : 4 fine sand) on the rough side of single or half brick wall.
Distempering with dry distemper of approved brand and manufacture (two or more coats) and of required shade on new work including priming coat of whiting to give an even shade.
Finishing walls with water proofing cement paint of approved brand and manufacture and required shade on new work (three or more coats) to give an even shade.
Applying priming coat with ready mixed pink primer of approved brand and manufacture on wood complete.
Painting two or more coats (excluding priming coat) with superior ready mixed paint for wood work of approved brand and manufacture in all shades on new work to give an even shade.
Painting two or more coats on GI sheets with ready mixed superior paint of approved brand and manufacture on new work to give an even shade.
Providing corrugated G.I.sheet roofing fixed with galvanised iron J or L hooks, bolts & nuts 8 mm dia with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead complete, excluding the cost of purlins, rafters and trusses. a) 0.80 mm thick GI sheet
Providing and fixing on wall face C.I. rain water pipe including filling the joints with spun yarn soaked in neat cement slurry and cement mortar 1 : 2 ( 1 cement : 2 fine sand). c)150 mm diameter pipe
Construction of cement concrete drain 30 cm wide and 23 cm deep in cement concrete 1 : 3 : 6 (1 cement : 3 sand : 6 hard graded stone chips/shingle 40 mm and down gauge) 8 cm thick on sides and bottom and plastering on all exposed surfaces with 12 mm thick cement mortar1 : 3 (1 cement : 3 fine sand) including shuttering complete.
Making plinth protection with 2nd class bricks on edge in cement mortar 1 : 6 (1 cement : 6 fine sand) over 7.50 cm bed of dry bricks aggregate 40 mm nominal size rammed consolidated and grouted with fine sand and the top of bricks pointed with cement mortar 1 : 2 (1 cement : 2 fine sand).
Providing and fixing GI pipes complete with GI fittings and clamps including cutting and making good the walls (internal work). a) 15mm nominal bore.
Providing and fixing GI pipes complete with GI fittings including trenching and refilling etc (external work). d) 32 mm nominal bore
Providing and fixing brass bib cock of approved quality. a) 15mm nominal bore.
Providing and fixing brass stop cock of approved quality. a) 15 mm nominal bore
b) 32 mm nominal bore
Providing and fixing PVC connection pipe with brass union 30cm length. a) 15mm nominal bore.
b) 20mm nominal bore.
Providing and fixing white vitreous china type water closet pedestal (European type WC pan) with seat and lid CP brass hinges and rubber buffers, 12.5 Litres high level CI flushing cistern with fittings RS or CI brackets, galvanized steel telescopic flush pipe with fittings and clamps, 20 GI overflow pipe with specials and mosquito proof coupling of approved municipal design and GI chain and pull complete including painting of cistern and fittings, cutting making good the walls and floors where required. a) WC pan with white plastic seat and lid.
Providing and fixing 600x450 mm bevelled edge mirror or superior glass (of approved quality) complete with 6 mm thick asbestos sheet ground fixed to wooden cleadt with CP brass screws and washers.
Providing and fixing white vitreous china wash basin with RS or CI brackets painted white 15 mm CP brass pillar taps and CP brass chain with rubber plug 32 mm CP brass waste of standard pattern, 32 mm dia CP brass trap and MI unions complete, including cutting and making good the walls where required. a) Flat back wash basin size 550x400 mm with a pair of 15 mm CP brass pillar taps of heavy quality.
Providing and fixing rubber plug for sink or wash basin.
Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x430x265 mm sizes respectively with CI automatic flushing cistern with fittings, RS or CI brackets standard size galvanized steel flush pipe and spreaders with brass unions and GI clamps complete including painting of cistern and fittings, cutting and making good the walls and floors where required. d) Range of four urinals with 15 Litre CI automatic flushing cistern
Providing and fixing sand cast iron/ cast iron (spun) soil, waste and vent pipes. a) 50 mm dia
b) 100 mm dia
Providing and fixing sand cast iron heel rest sanitary bend. a) 100 mm dia
a) 50 mm dia
Making soak pit 2.50 m dia 3 m deep with 45 x 45 cm dry brick honeycomb shaft and SW drain pipe 100 mmdia 1.80 m long complete as per standard design.
II) Septic tank Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock), lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required, into plinth sides of foundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus soil as directed within a lead of 50m.
Providing and laying in foundations and plinth cement concrete 1 : 5 : 10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering.
Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with 1 : 2 : 4 (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size).
Reinforced cement concrete in walls (any thickness) including attached pillasters, buttresses, plinth and string course, fillets etc from top of foundation up to floor two level including finishing and plastering the exposed surfaces with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface excluding cost of centring, shuttering and reinforcement in : a) 1 : 1.5 : 3 (1 cement : 1.5 corase sand : 3 stone aggregate 20 mm nominal size)
Cement concrete flooring 1 : 2 : 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement. C) 75mm thick
Centring and shuttering including strutting, propping etc. and removal of form work for: b) Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.
b) Suspended floors, roofs, landing shelve and theirsupports, balconies and chajjas (3.50m height)
Reinforcement of RCC work including bending, binding and placing in position complete. a)Tar/ TMT steel
20 mm cement plaster 1 : 3 (1 cement : 3 fine sand).
Neat cement punning
Brick work with best available local bricks in foundations and plinth in cement mortar 1:3 (1 cement : 3 fine sand).
Providing and fixing sand cast iron/ cast iron (spun) soil, waste and vent pipes. a) 100 mm dia
b) 50 mm dia
Providing and fixing sand cast iron single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. a) 100 x 100 x 100 mm
Providing and fixing sand cast iron single equal plain junction of required degree. a) 100 x 100 x 100 mm
Making soak pit 2.50 m dia 3 m deep with 45 x 45 cm dry brick honeycomb shaft and SW drain pipe 100 mmdia 1.80 m long complete as per standard design..
ELECTRIFICATION A. POINT WIRING Point wiring in PVC conduit, with modular type switch. Wiring for light point /fan point/exhaust fan point/call bell point with 1.5 Sq.mm FR PVC insultated copper conductor single core cable in surface/recessed PVC conduit,with modular switch, modular switch, suitable size G.I. box and earthing the point with 1.5 sq. mm. FR PVC insulated copper conductor single core cable etc. as required. Group C
Circuit/sub-main wiring in PVC conduit :- Wiring for circuit/submain wiring alongwith earth wire with the following sizes of PVC insulated copper conductor, single core cable in surface/recessed PVC conduit as required. a) 2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire (5A Plug).
b) 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire (for ckt wiring).
c)2 x 4 sq. mm + 1 x 4 sq. mm earth wire(for power point).
S/F PVC conduit :- Supplying and fixing of following sizes of PVC conduit along with accessories in surface /recess including cutting the wall and making good the same in case of recessed conduit as required. A) 25 mm
S/F modular type switch/socket :- Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. a) 5/6 Amps Switch
b) 15/16 Amps Switch
c) 5/6 Amps Socket
d) 15/16 Amps socket outlet
S/F modular boxes, Base & Cover Plate :- Supplying and fixing following size/module GI box along with modular base and cover plate for modular switch in recess extr as required. 1 or 2 module (75 mm x 75 mm)
S/F modular type electronic fan regulator :- Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
S/F modular type blanking plate :- Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate etc. as required.
S/F light plug point modular type accessories :- Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection, painting etc. as required.(For light plugs to be used in non residential buildings).
S/F power plug point modular type accessories:- Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 15/16 & 5/6 amps modular socket outlet and 15/16 amps modular switch, connection, painting etc. as required.
ITC fluorescent fitting directly on surface :- Installation, testing and commissioning of pre-wired, fluorescent fitting/compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/wall, including connection with 1.5 sq. mm FR PVC insualted, copper conductor, single core cable and earthing etc. as required.i/c Fittings
ITC ceiling fan :- Installation, testing and commissioning of ceiling fan including the down rods of standard length (upto 30 cm) with 1.5 sq. mm FR PVC insualted, copper conductor, single core cable and earthing etc. as required.i/c Standard fan ( bajaj or Khaitan)
Carriage of fan :- Carriage of ceiling fan and regulator/exhaust fan from store to site as required.
S/F call bell/buzzer :- Supplying and fixing call bell/buzzer suitable for D.C/A.C single phase , 230 volts, complete as required.
S/F steel conduit :- Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. a) 20 mm
Wiring in existing conduit :- Supplying and drawing of following sizes of FR PVC insulated copper conductor ,single core cable in the existing surface /recessed steel /PVC conduit as required. a) 2 x 1.5 sq. mm
b) 2 x 2.5 sq. mm
B. MCB DISTRIBUTION BOARDS S/F prewired SP MCB DB : Supplying and fixing following way, single pole and neutral, prewired, sheet steel, MCB distribution board, 240 volts, on surface/recess, complete with loose wire box, terminal blocks, duly prewired with suitble size FR PVC insulated copper conductor up to terminal blocks, tinned copper bus bar, neutral link earth bar, din bar, detachable gland plate,interconnections,phosphatized and powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) a) (2 +8) way double door
S/F prewired TP MCB DB : Supplying and fixing following way, three pole and neutral, prewired, sheet steel, MCB distribution board, 415 volts, on surface/recess, complete with loose wire box, terminal blocks, duly prewired with suitble size FR PVC insulated copper conductor up to terminal blocks, tinned copper bus bar, neutral link earth bar, din bar, detachable gland plate,interconnections,phosphatized and powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) a) 8 way (4+24), Double door
S/F 'C' series,SP MCB Supplying and fixing 5 amps to 32 amps rating, 240 volts.'C' series, miniature circuit breaker suitable for lighting and other loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. a) Single Pole
Single Pole and Neutral
S/F TP MCB isolator :- Supplying and fixing following rating, Four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required . 63 Amps
S/F SPN RCCB :- Supplying and fixing following rating, double pole,(single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 100 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63Amps
S/F 20A SPN MCB Industrial Socket outlet :- Supplying & Fixing 20 A 240V SPN Industrial Type Socket Outlet with 2 Pole earth metal enclosed plug top along with 20 A "C Series" SP MCB in sheet metal enclosure on surface or in recess with chained metal cover for the socket outlet & complete with connections, testing & commissioning as required.
C. CABLE WORK MV cable laying upto 400 sqmm. in pipe Laying of one number PVC insulated and PVC sheathed power cable of 1.1 KV grade of size exceeding 120sq. mm but not exceeding 400 sq. mm in the existing RCC Hume / Stoneware / G. I. pipe etc. as required
MV cable laying upto 400 sqmm. On surface Laying of one number PVC insulated and PVC sheathed power cable of 1.1 KV grade of size exceeding 120 sq. mm but not exceeding 400 sq. mm direct in the Surface as required.
11 KV CABLE JOINTING WITH CAST RESIN COMPOUND Supplying and making INDDOR Cable end jointing with cast resin compound , including lugs and and other jointing materils, for followings size of 3 core XLPE ALUMINIUM CONDUCTOR CABLE OF 11 KV GRADE AS REQUIRED. 3CX120 SQMM
11 KV CABLE JOINTING WITH CAST RESIN COMPOUND Supplying and making OUTDDOR Cable end jointing with cast resin compound , including lugs and and other jointing materils, for followings size of 3 core XLPE ALUMINIUM CONDUCTOR CABLE OF 11 KV GRADE AS REQUIRED. 3CX120 SQMM
F/I cable trays Fabricating and installing following size of perforated M.S. cable trays including horizontal and vertical bends, reducers, tees, cross members and other accessories as required and duly suspended from the ceiling with M.S. Suspenders and including painting with powder coating etc. as required. 100 mm width x 50 mm depth x 1.6 mm thickness
D. EARTHING G.I Plate Electrode :- Earthing with G.I plate 600 x 600 x 6 mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and water pipe etc.(but without charcoal or coke and salt) complete as required.
Copper Plate Electrode :- Earthing with Copper plate 600 x 600 x 3 mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and water pipe etc.(but without charcoal or coke and salt) complete as required.
Salt / charcoal for plate earth electrode :- Extra for using salt and charcoal for G.I or Copper plate earth electrode as required.
Providing and fixing 25 mm x 6 mm G.I earth strip from earth electrode as required.
Providing and fixing 25 mm x 5 mm Cu. strip on surface or in recess for connection etc. as required.
S/L 8 SWG Copper wire in ground Providing and fixing 8 SWG Copper wire from earth electrode as required .
III) SH: Type - V Quarter Earth work in excavation in foundation and trenches in soils containing 50% or more of shingle or small size boulders upto 30 cm size, lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers when required, into plinth, sides of foundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated soil as directed within a lead of 50m.
Re-filling excavated earth in foundations and plinth etc. in 15 cm layer including ramming and watering etc. complete.
Filling in plinth with sand under floors including watering, ramming, consolidating and dressing complete.
Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and Shuttering
Reinforcement of RCC work including bending, binding and placing in position complete. Tar/ TMT steel
Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcement in : a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
Centring and shuttering including strutting, propping etc and removal of form work for : a) Foundation, footings, bases of columns etc. and mass concrete.
b) Column, pillars, posts and struts etc.
c) Lintels, beams, girders, bressumers and cantilevers etc.
d) Suspended floors, roofs, landings shelves and their supports, balconies and chajjas (3.5 m height).
Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement. a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement. a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
Providing and laying damp proof course 38 mm thick with cement concrete 1 : 2 : 4 (1 cement : 2 coarse sand : 4 stone aggregate 12.5 mm nominal size).
Reinforced cement concrete in chajjas exceeding 15mm in thickness upto floor two level centring and shuttering complete but excluding the cost of reinforcement with M20( 1 cement: 1.5 coarse sand : 3 stone aggregate 20 mm nominal size
Brick work with best available local bricks in foundations and plinth in cement mortar 1:4 (1 cement : 4 fine sand).
Half brick masonry with best available local bricks in cement mortar 1:4 (1 cement:4 coarse sand) in foundation and plinth
Providing approved best available local wood (Class - B II) work in frames of doors, windows clerestory windows and other frames, wrought framed and fixed in position.
Providing best available local wood (Class - B II) work in frames of false ceiling, partitions and trusses etc, sawn and put up in position.
Providing and fixing panelled, glazed or panelled and glazed shutters for doors, windows and clerestory windows including aluminium butt hinges with necessary screws. a) 38mm thick best available local wood class - B I
Providing and fixing 30 mm thick wire gauge shutters using galvanized mild steel wire gauge of IS gauge designation 85G with wire of dia 0.56 mm for doors, windows and clerestory windows including iron butt hinges with necessary screws. a) Best available local wood class -B I
Providing and fixing 2.50 cm thick approved local wood eaves boards 23 cm wide with necessary mouldings etc.
Providing and fixing MS grills of required pattern in wooden frames of windows etc with MS flat, square or round bars with round headed bolts and nuts or by screws. a) Ornamental grill.
Providing and fixing aluminum sliding door bolts anodised transparent or dyed to required color or shade with nuts and screws etc complete. a) 300 x 16 mm
Providing and fixing aluminum Tower bolts anodized or transparent or dyed to required color or shade with necessary screws etc complete. a) 250 x 10 mm
Providing and fixing aluminum Handles anodised transparent or dyed to required color or shade with necessary screws etc complete. a) 125 mm
Providing and fixing MS Hooks and Eyes. d) 150 mm
Providing and fixing 12 mm thick and 100 mm wide pelmet with 25 mm dia wooden curtain rod and brackets including fixing with 25 x 3 mm MS flat 10 cm long and plugs etc complete. a) Timber class - A IV
Steel work in built up tubular trusses including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer welded and bolted including special shaped washers etc complete (welding to be paid separately).
Providing and fixing MS fan clamp type I of 16 mm dia MS bar bent to shape with hooked ends in RCC slabs during lying including painting the exposed portion of loop all as per standard design complete.
Providing and fixing MS round holding down bolts with nuts and washer plates etc complete.
Providing and fixing plain, square edged wooden beading 38 mm x 12 mm section with screws of approved quality for ceiling. a) Best local approved quality wood.
Extra for making chamfered edges of beading.
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete a) Size of Tile 500x500 mm
Providing corrugated G.I.sheet roofing fixed with galvanised iron J or L hooks, bolts & nuts 8 mm dia with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white leadcomplete, excluding the cost of purlins, rafters and trusses. b) 0.63 mm thick GI sheet
Providing ridges or hips 60 cm overall in plain G.I. sheet fixed with galvanised iron J or L hooks, bolts and nuts 8 mm dia. G.I. limpet and bitumen washers complete. b) 0.63 mm thick GI sheet
Providing and fixing 4.0 mm thick asbestors plain sheet ceiling of approved quality with necessary nails etc.complete (frame work for base to be paid separately).
15 mm cement plaster 1 : 4 (1 cement : 4 fine sand) on the rough side of single or half brick wall.
12 mm cement plaster 1 : 4 (1 cement : 4 fine sand).
Neat cement punning.
Distempering (two or more coats) with oil bound washable distemper of approved brand and manufacture and of required shade on new work over and including a priming coat with distemper primer of approved brand and manufacture to give an even shade.
Applying one coat of distemper primer of approved brand and manufacture on wall surface.
Applying priming coat with ready mixed pink primer of approved brand and manufacture on wood work complete.
Painting two coats with oil type wood preservative of approved brand and manufacture on new work.
Applying priming coat with ready mixed primer of approved brand and manufacture on steel work.
Painting two or more coats on GI sheets with ready mixed superior paint of approved brand and manufacture on new work to give an even shade.
Painting two or more coats (excluding priming coat) with superior ready mixed paint for steel work of approved brand and manufacture in all shades on new work to give an even shade.
Finishing walls with water proofing cement paint of approved brand and manufacture and required shade on new work (three or more coats) to give an even shade.
Making plinth protection 50 mm thick of cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 stone aggregate using 20 mm nominal size) over 75 mm bed of stone ballast 40 mm nominal size well rammed and consolidated and grouted with fine sand including finsihing the top smooth.
Construction of cement concrete drain 30 cm wide and 23 cm deep in cement concrete 1 : 3 : 6 (1 cement : 3 sand : 6 hard graded stone chips/shingle 40 mm and down gauge) 8 cm thick on sides and bottom and plastering on all exposed surfaces with 12 mm thick cement mortar1 : 3 (1 cement : 3 fine sand) including shuttering complete.
Providing and laying cement concrete 1 : 5 : 10 (1 cement : 5 lime sand : 10 graded stone aggregate 40 mm nominal size) all around SW Pipe including bed concrete 15 cm thick as per standard design. a) 100 mm dia SW pipes
Providing and fixing white vitreous china water closet squatting pan size 580 mm size. b) Orissa Pattern WC Pan
Providing and fixing white vitreous china pedestal type (European type) WC pan.
Providing and fixing white vitreous china wash basin with RS or CI brackets painted white 15 mm CP brass pillar taps and CP brass chain with rubber plug 32 mm CP brass waste of standard pattern, 32 mm dia CP brass trap and MI unions complete, including cutting and making good the walls where required. a) Flat back wash basin size 550x400 mm with a pair of 15 mm CP brass taps of heavy quality.
Providing and fixing kitchen sink including making all connection excluding cost of fittings. a) White glazed fire clay sink size 600x450x150 mm
Providing and fixing 600x450 mm bevelled edge mirror or superior glass (of approved quality) complete with 6 mm thick asbestos sheet ground fixed to wooden cleat with CP brass screws and washers.
Providing and fixing 600 x 120 mm glass shelf with CP brass brackets and guard rail complete, fixed to wooden cleats with CP brass screws.
Providing and fixing CP brass towel rail complete with CP brass brackets fixed to wooden cleadt with CP brass screws (heavy quality). a) 750 x 20 mm size
Providing and fixing CP brass waste for wash basins and sinks. a) 32 mm dia
Cement concrete flooring 1 : 2 : 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement b) 50 mm thick
Providing and fixing GI pipes complete with GI fittings and clamps including cutting and making good the walls (internal work). a) 15 mm nominal bore
b) 20 mm nominal bore
Providing and fixing brass bib cock of approved quality. a)15 mm nominal bore
Providing and fixing brass stop cock of approved quality. a) 15 mm nominal bore
FURNITURES Wooden Bed
Cane Chair
Pegtable
Writing Table
Coffee Table
Dining Table(6'x4')
Dining Chair
Wooden meat safe
Sofa Set
Centre Table
Dressing Table
Executive Office Chair
Office Chair
Office Table
Kitchen Table with Stool
Storewell Type Almirah
Mattress of 4" thick for beds,3'-3"x6'-6"
Water filter 10 Ltr Capacity
ELECTRIFICATION A. POINT WIRING Point wiring in PVC conduit, with modular type switch. Wiring for light point /fan point/exhaust fan point/call bell point with 1.5 Sq.mm FR PVC insultated copper conductor single core cable in surface/recessed PVC conduit,with modular switch, modular switch, suitable size G.I. box and earthing the point with 1.5 sq. mm. FR PVC insulated copper conductor single core cable etc. as required. Group C
Circuit/sub-main wiring in PVC conduit :- Wiring for circuit/submain wiring alongwith earth wire with the following sizes of PVC insulated copper conductor, single core cable in surface/recessed PVC conduit as required. a) 2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire (5A Plug).
b) 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire (for ckt wiring).
c) 2 x 4 sq. mm + 1 x 4 sq. mm earth wire(for power point).
S/F PVC conduit :- Supplying and fixing of following sizes of PVC conduit along with accessories in surface /recess including cutting the wall and making good the same in case of recessed conduit as required. a) 25 mm
S/F modular type switch/socket :- Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. a) 5/6 Amps Switch
b) 15/16 Amps Switch
c) 5/6 Amps Socket
d) 15/16 Amps socket outlet
S/F modular boxes, Base & Cover Plate :- Supplying and fixing following size/module GI box along with modular base and cover plate for modular switch in recess extr as required. a) 1 or 2 module (75 mm x 75 mm)
S/F modular type electronic fan regulator :- Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
S/F modular type blanking plate :- Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate etc. as required.
S/F light plug point modular type accessories :- Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection, painting etc. as required.(For light plugs to be used in non residential buildings).
S/F power plug point modular type accessories:- Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 15/16 & 5/6 amps modular socket outlet and 15/16 amps modular switch, connection, painting etc. as required.
ITC fluorescent fitting directly on surface :- Installation, testing and commissioning of pre-wired, fluorescent fitting/compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/wall, including connection with 1.5 sq. mm FR PVC insualted, copper conductor, single core cable and earthing etc. as required.i/c Fittings
ITC ceiling fan :- Installation, testing and commissioning of ceiling fan including the down rods of standard length (upto 30 cm) with 1.5 sq. mm FR PVC insualted, copper conductor, single core cable and earthing etc. as required.i/c Standard fan ( bajaj or Khaitan)
Carriage of fan :- Carriage of ceiling fan and regulator/exhaust fan from store to site as required.
S/F call bell/buzzer :- Supplying and fixing call bell/buzzer suitable for D.C/A.C single phase , 230 volts, complete as required.
S/F steel conduit :- Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm
Wiring in existing conduit :- Supplying and drawing of following sizes of FR PVC insulated copper conductor ,single core cable in the existing surface /recessed steel /PVC conduit as required. 2 x 1.5 sq. mm
2 x 2.5 sq. mm
B. MCB DISTRIBUTION BOARDS S/F prewired SP MCB DB : Supplying and fixing following way, single pole and neutral, prewired, sheet steel, MCB distribution board, 240 volts, on surface/recess, complete with loose wire box, terminal blocks, duly prewired with suitble size FR PVC insulated copper conductor up to terminal blocks, tinned copper bus bar, neutral link earth bar, din bar, detachable gland plate,interconnections,phosphatized and powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) a) (2 +8) way double door
S/F prewired TP MCB DB : Supplying and fixing following way, three pole and neutral, prewired, sheet steel, MCB distribution board, 415 volts, on surface/recess, complete with loose wire box, terminal blocks, duly prewired with suitble size FR PVC insulated copper conductor up to terminal blocks, tinned copper bus bar, neutral link earth bar, din bar, detachable gland plate,interconnections,phosphatized and powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) a) 8 way (4+24), Double door
S/F 'C' series,SP MCB Supplying and fixing 5 amps to 32 amps rating, 240 volts.'C' series, miniature circuit breaker suitable for lighting and other loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. a) Single Pole
b) Single Pole and Neutral
S/F TP MCB isolator :- Supplying and fixing following rating, Four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required . 63 Amps
S/F SPN RCCB :- Supplying and fixing following rating, double pole,(single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 100 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63Amps
S/F 20A SPN MCB Industrial Socket outlet :- Supplying & Fixing 20 A 240V SPN Industrial Type Socket Outlet with 2 Pole earth metal enclosed plug top along with 20 A "C Series" SP MCB in sheet metal enclosure on surface or in recess with chained metal cover for the socket outlet & complete with connections, testing & commissioning as required.
C. CABLE WORK MV cable laying upto 400 sqmm. in pipe Laying of one number PVC insulated and PVC sheathed power cable of 1.1 KV grade of size exceeding 120sq. mm but not exceeding 400 sq. mm in the existing RCC Hume / Stoneware / G. I. pipe etc. as required
MV cable laying upto 400 sqmm. On surface Laying of one number PVC insulated and PVC sheathed power cable of 1.1 KV grade of size exceeding 120 sq. mm but not exceeding 400 sq. mm direct in the Surface as required.
11 KV CABLE JOINTING WITH CAST RESIN COMPOUND Supplying and making INDDOR Cable end jointing with cast resin compound , including lugs and and other jointing materils, for followings size of 3 core XLPE ALUMINIUM CONDUCTOR CABLE OF 11 KV GRADE AS REQUIRED. 3CX120 SQMM
11 KV CABLE JOINTING WITH CAST RESIN COMPOUND Supplying and making OUTDDOR Cable end jointing with cast resin compound , including lugs and and other jointing materils, for followings size of 3 core XLPE ALUMINIUM CONDUCTOR CABLE OF 11 KV GRADE AS REQUIRED. 3CX120 SQMM
F/I cable trays Fabricating and installing following size of perforated M.S. cable trays including horizontal and vertical bends, reducers, tees, cross members and other accessories as required and duly suspended from the ceiling with M.S. Suspenders and including painting with powder coating etc. as required. 100 mm width x 50 mm depth x 1.6 mm thickness
D. EARTHING G.I Plate Electrode :- Earthing with G.I plate 600 x 600 x 6 mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and water pipe etc.(but without charcoal or coke and salt) complete as required.
Copper Plate Electrode :- Earthing with Copper plate 600 x 600 x 3 mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and water pipe etc.(but without charcoal or coke and salt) complete as required.
Salt / charcoal for plate earth electrode :- Extra for using salt and charcoal for G.I or Copper plate earth electrode as required.
Providing and fixing 25 mm x 6 mm G.I earth strip from earth electrode as required.
Providing and fixing 25 mm x 5 mm Cu. strip on surface or in recess for connection etc. as required.
S/L 8 SWG Copper wire in ground Providing and fixing 8 SWG Copper wire from earth electrode as required .
SH : Septic Tank Earth work in excavation in foundation trenches in soils containing 50% or more of shingle or small size boulders upto 30 cm size, lift upto 1.50m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers when required, into plinth, sides of foundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated soil as directed within a lead of 50m. a) Hard Soil
Providing and laying cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) excluding the cost of centring an shuttering in: a) Foundations plinth
Brick work with best available local bricks in foundation and plinth in cement mortar 1 : 3 (1 cement :3 fine sand).
Providing and laying cement concrete 1 : 2 : 4 (1 cement : 2 coarse sand : 4 aggregate 20 mm nominal size)excluding the cost of centring and shuttering in: a) Foundations and plinth
Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1:3(1 cement :3 fine sand ) of thickness not exceeding 6mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
Reinforcement of RCC work including bending, binding and placing in position complete. a) Tar/TMT steel
Constructing brick masonry manhole with 2nd class bricks in cement mortar 1 : 5 (1 cement :5 fine sand) RCC top slab with 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4 stone single 20 mm nominal size), foundation concrete 1 : 4 : 8 mix (1 cement : 4 coarse sand : 8 stone aggregate 40 mm nominal size) inside plastering 12 mm thick with cement mortar 1 : 3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement and making channels in cement concrete 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size) neatly finished complete as per standard design Inside size 90 x 80 cm and 45 cm deep including CI cover with frame (light duty) 455 x 610 mm internal dimensions total weight of cover and frame to be not less than 38 Kg (weight of cover and frame to be not less than 38 kg, (weight of cover 23 Kg and weight of frame 15 Kg).
12 mm cement plaster 1 : 3 (1 cement :3 fine sand).
Making soak pit 2.50 m dia 3 m deep with 45 x 45 cm dry brick honeycomb shaft and SW drain pipe 100 mmdia 1.80 m long complete as per standard design.
IV) SH: C/O Laundry cum Drying Area Construction of pre-fabricated Laundry (10.00 m x 20.00 m) (Manufacture, Supply, Erection, Civil and Electrical work.) SIZE OF BUILDING:- L 24.00m Wide 10.00 m (Including 2.0 m Verandah on one side) CLEAR HEIGHT:- 3.5 m (False Ceiling height MAIN BUILDING:- Elevated steel footing -600mm from ground level ,ROOF:- Sheet 0.63 Thk PPGI FLOORING:- Deck sheet with PCC flooring of 100mm Thk ,- Parking Tiles, ACCESSORIES:- Wiring with havels Led Fitting, Ceiling Fans Etc as required
V) C/o Pre-fabricated MI Room (For Boys) Construction of pre-fabricated MI room (21.0 m x 6.5 m) including 2m wide verandah in front (Manufacture, Supply, Erection, Civil work and Electrical work) MAJOR SPECIFICATION. SIZE OF BUILDING:- L 21.0m Wide 6.50 m (Including 1.5 m Verandah) CLEAR HEIGHT:- 3.5 m (False Ceiling height. MAIN BUILDING:- Elevated steel footing -600mm from ground level, Main Building - Pre-fab type, Wall -Puf insulated-50mm Thick, False Ceiling- 30mm Thick Puf Insulated panels ROOF:- Sheet 0.63 Thk PPGI. FLOORING:- Deck sheet with PCC flooring of 100mm Thk , Top Finishing:- Corridor Area:- Vitrified tiles, Verandah- Parking Tiles, Room - Ceramic Tiles and Bathroom and Toilet- Non Skid Ceramic Tiles. DOOR:- Main- Pressed Steel Frame with Puf Shutter. ACCESSORIES:- a) Wiring with havels Led Fitting, Ceiling Fans Exhaust Fan Etc as required. b) windows & ventilators with Fixed Mosquito/Fly wire Mesh as required. c) Fixing of 300mm diaTurbo ventilation
C/o Septic tank (RCC) Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock), lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required, into plinth sides of foundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus soil as directed within a lead of 50m.
Providing and laying in foundations and plinth cement concrete 1 : 5 : 10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering.
Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with 1 : 2 : 4 (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size).
Reinforced cement concrete in walls (any thickness) including attached pillasters, buttresses, plinth and string course, fillets etc from top of foundation up to floor two level including finishing and plastering the exposed surfaces with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface excluding cost of centring, shuttering and reinforcement in : a) 1 : 1.5 : 3 (1 cement : 1.5 corase sand : 3 stone aggregate 20 mm nominal size)
Cement concrete flooring 1 : 2 : 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement. C) 75mm thick
Centring and shuttering including strutting, propping etc. and removal of form work for: b) Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.
c) Suspended floors, roofs, landing shelve and theirsupports, balconies and chajjas (3.50m height)
Reinforcement of RCC work including bending, binding and placing in position complete. a)Tar/ TMT steel
20 mm cement plaster 1 : 3 (1 cement : 3 fine sand).
Neat cement punning
Brick work with best available local bricks in foundations and plinth in cement mortar 1:3 (1 cement : 3 fine sand).
Providing and fixing sand cast iron/ cast iron (spun) soil, waste and vent pipes. a) 100 x 100 x 100 mm
b) 50 mm dia
Providing and fixing sand cast iron single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. a) 100 x 100 x 100 mm
Providing and fixing sand cast iron single equal plain junction of required degree. a) 100 x 100 x 100 mm
Making soak pit 2.50 m dia 3 m deep with 45 x 45 cm dry brick honeycomb shaft and SW drain pipe 100 mmdia 1.80 m long complete as per standard design..
VI) SH: C/o Pre-fabricated 60 Bedded Boys Hostel Building Construction of pre-fabricated hostel building (43.3 m x 19.5 m) for 60 student with one hostel warden (Manufacture, Supply, Erection, Civil work, Electrical work, Sanitation and Plumbing work) MAJOR SPECIFICATION. SIZE OF BUILDING:- L 43.3m Wide 19.5 m (Including 2.5 m Verandah on both side)CLEAR HEIGHT:- 3.5 m (False Ceiling height. MAIN BUILDING:- Elevated steel footing -600mm from ground level, Main Building - Pre-fab type, Wall -Puf insulated-50mm Thick, False Ceiling- 30mm Thick Puf Insulated panels ROOF:- Sheet 0.63 Thk PPGI. FLOORING:- Deck sheet with PCC flooring of 100mm Thk , Top Finishing:- Corridor Area:- Vitrified tiles, Verandah- Parking Tiles, Room - Ceramic Tiles and Bathroom and Toilet- Non Skid Ceramic Tiles DOOR:-Main- Pressed Steel Frame with Puf Shutter ACCESSORIES:- a) Wiring with havels Led Fitting, Ceiling Fans, Exhaust Fan Etc as required. b) Water supply with sanitation: PVC water reservoir with staging, ECW and ICW fittings as required with low down system, all necessary bathroom and toilet fitting, wash basin, kitchen sink and windows with ventilators as required. All connection to incoming water supply from reservoir (Our Supply), Drain/Outlet from Toilet and Bathroom to Septic Tank. c) windows & ventilators with Fixed Mosquito/Fly wire Mesh as required. d) Fixing of 600mm diaTurbo ventilation ( including fittings & eqipments)
VII) SH: C/o Pre-fabricated Class Room Construction of pre-fabricated Class Room (8.00 m x 8.0 m) including 2m wide verandah (Manufacture, Supply, Erection, Civil and Electrical work.) MAJOR SPECIFICATION. SIZE OF BUILDING:- L 12.00m Wide 8.00 m (Including 2.0 m Verandah on one side) CLEAR HEIGHT:- 3.5 m (False Ceiling height. MAIN BUILDING:- Elevated steel footing -600 mm from ground level, Main Building - Pre-fab type, Wall -Puf insulated-50mm Thick, False Ceiling- 30mm Thick Puf Insulated panels ROOF:- Sheet 0.63 Thk PPGI. FLOORING:- Deck sheet with PCC flooring of 100mm Thk , Top Finishing:- Corridor Area:- Vitrified tiles, Verandah- Parking Tiles, Room - Ceramic Tiles and Bathroom and Toilet- Non Skid Ceramic Tiles DOOR:-Main- Pressed Steel Frame with Puf Shutter Window :-All the window Should be made up of Pressed Steel Frame with Puf Shutter with Fixed Mosquito wire Mesh at outside. ACCESSORIES:- a) Wiring with havels Led Fitting, Ceiling Fans, Exhaust Fan Etc as required. b) FIRE FIGHTING: Carbon Dioxide Fire Extinguisher of capacity 4.5 Kg.. c) windows & ventilators with Fixed Mosquito/Fly wire Mesh as required.
M/s Kunyung Construction Agency
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .