| 1 | L1₹33.5 LAccepted-AOC | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹36.5 L+₹2.5 L (7.42%)Rejected-Finance N A | NEW DELHI | DELHI | 110001 | L2 | Rejected-Finance Being other than lowest | |
| 3 | L3₹39.0 L+₹5.0 L (14.7%)Rejected-Finance RAMA PARK A 121 BLOCK A UTTAM NAGAR WEST DELHI DELHI 110059 | DELHI | WEST DELHI | DELHI | 110059 | L3 | Rejected-Finance Being other than lowest | |
| 4 | L4₹41.4 L+₹7.4 L (21.7%)Rejected-Finance 22 319 GALI NO 5 MAHABIR PARK BAHADURGARH 124507 HARYANA | JHAJJAR | HARYANA | 124507 | L4 | Rejected-Finance Being other than lowest | |
| 5 | L5₹43.7 L+₹9.7 L (28.6%)Rejected-Finance | L5 | Rejected-Finance Being other than lowest |
Tender Value
₹47.2 L
EMD Value
₹94,380
Closing Date
30 Oct 2023, 6:00 pmClosed
GE (EAST) DELHI CANTT-10
GE (EAST) DELHI CANTT-10
SPL REPAIR TO BLDG NO T-67 (SCIC WARD) AT BASE HOSPITAL UNDER GE (EAST) DELHI CANTT-10
2023_MES_622399_1
GE/DE-68/2023-24
Open Tender
Civil Works
Item Rate
180 days
GE (EAST) DELHI CANTT-10
Class D Cat a (i)
8 documents required · 8 mandatory
₹500
Yes
GE (EAST) DELHI CANTT-10
₹94,380
Yes
10 Nov 2023
9 Oct 2023
1 Nov 2023
9 Oct 2023
30 Oct 2023
23 Oct 2023
Amount
Dismantling Asbestos cement corrugated or semi corrugated sheets in roof covering complete all as specified and as directed by Engg-in-Charge.
Dismantling timber scantlings 40 sq. cm and over in section, in any position framed work complete all as specified and as directed by Engg-in-Charge.
All same as per srl item No 2 above but as in fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section complete all as specified and as directed by Engg-in-Charge.
S&F Steel work as in tubular trusses, purlins, rafter, vertical post and similar works including special shaped washer etc complete using ERW or induction butt welded tubes confirming to IS- 1161 -1979-grade St-240 including one shop coat of zinc chromate primer paint incl prepartion of surface at contractor workshop before fabrication complete all as specified and directed.
S & F plain MS plate incl cutting / welding & drilling (Fe 410- w Gde-E 250 Quality A) complete all as specified & directed.
S&F Mild steel screw bolts (machine made) dia of neck 10mm with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long complete all as specified.
Supply and fixing in position galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, Chajja etc fixed with self tapping screws as specified high tensile alloy steel trap sheet having 55 MPA yeild strength and zinc (galvanized ) + Aluminum combined, coating of 150 GSM /PM2(AZ-150) of 50mm TCT having top colour coat of regular modified polyester/silicon modified polyester/HDEP polyester of 18 to 20 micron and back coat of 5 to7 micron Epoxy primer fixes. RMR 1040 profile width 1125 mm complete all as specified & directed.
All as per item No 7 above but plain sheet as in ridge/valley gutter
Demolition/dismantling of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets
S&F GI powder coated snap grid frame work for false ceiling (Size of grid 605X605 mm) complete all as specified and directed.
S&F Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I.flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and directed.
S&F 4 mm thick Eco building board fixed or laid/inserted to GI/ Aluminium framework with screws complete all as specified and directed.
S&F Solid PVC Wall lining consisting of 5mm thick wood grain printed PVC sheet inclusive of solvent cement and fixing at site on PVC frame complete all as specified and directed.
S&F 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame acomplete all as specified and directed.
S & F powder coated aluminium anodised section 40 x 44mm x14 gauge for aluminium partition wall in wall in panel 1m x1m covered with 5mm thick plain/frosted tinted glass on top half portion and 5 mm thick Aluminium Composite panel fixed in half bottom portion complete all as specfied and directed. Make:- Jindal/ Hindalco/Balco
S&F aluminium powder coated door frame with partially glazed shutters single/ double leaf divided into two glazed panels including aluminium anodised snap beading and rubber gasket/lining for fixing of glass as directed. The frame shall be fixed with aluminium anodised bolt by drilling in the existing wall and with thrust bolt of suitable size all as directed. The frame and shutter will be made out of the following section and fitting a) Aluminium anodised door frame 101.60 mm x 44.75 mmx2mm fixed with aluminium thrust bolt in walls by drilling as directed. b) Aluminium anodised sides rail of shutter section 83.5mmx 44.5mm x 2mm c) Aluminium anodised bottom rail of shutter section 150mm x 44.5 mm x2mm. d) Aluminium anodised top and middle rail of shutter section 100mm x 44.5 mm x 2mm. e) Aluminium anodised tower bolt 200 mm long - 02 Nos in each leaf of Make Classic/Argent as approved. f) Aluminium anodised handle 250 mm long of approved Make Classic/Argent 02. No’s in each leaf. h) Glass Pane shall be 5.5 mm thick tinted glass. j) 5 mm thick Aluminium Composite panel and lock including complete all as specified and directed Make- JINDAL/HINDALCO/BALCO.
Supply, fabricating and fixing windows with frame of aluminium powder coated of extruded aluminium section two track with two sliding shutters with following sections (a) Frame section shall be 63.50 mmx38.10 mmx2 mm thick. (b) Two track bottom rail for sliding of shutters 61.85mm x 31.75mmx2mm thick. (c) Two track top section shall be 61.85mmx31.75mmx2mm thick(d) for sliding shutter handle& 'H' bottom section should be 40mmx(18mm+9)mmx1.45mm thick(e) sliding shutter to be provided with 5.5mm thick sheet glass( Modi/Saint gobain/tinted, plain, frosted (f) stainless steel wire clothes 0.36mm nominal dia of wire and average width of aperature 1.40mm complete all as specified and as directed
M&L for 18-20 mm thick of approved shade granite stoneZ Black (superior Quality) slab (table rubbed and polished as in floors, jambs, steps, cooking platform etc and the like, over & including 15 mm thick screed in CM 1:4, pointed in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including two strip of line make on (tread of stair case) granite complete all as specified and directed
M&L for Granite stone (of any type) 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone grinding and polishing complete including bedding layer of mortar 15 mm thick in CM 1:4 for laying floor finishes etc and the like including round cutting etc complete all as specified and directed.
S&F Stainless steel 20 mm dia curtain rod of medium weight including fixing SS brackets, curtain ring @ 7 nos/Rm and decorative end/Latto supports etc complete all as directed.
Demolition of brick work built in cement mortar of any description and including PCC Coping etc and disposal of all debris out side Mod land complete all as specified and directed.
M&L for brick work with sub class ‘B’ bricks straight or curved on plan exceeding 6 M mean radius, using old sise bricks built in CM 1:6
M&L for plastering 15 mm thick in CM 1:4 on fair faces of brick or concrete surfaces, finished the surface even and fair with using WPC @ 2% by weight of cement(If Required) (Note- WPC shall be measured and paid separately)
M&L for 15mm thick cement plaster on other than fair faces of brick work or concrete surfaces in CM 1:6 finished even and fair complete all as specified and directed
M&L for 25 mm thick PCC 1:2:4 type B-0 using 12.5mm graded stone aggregates as in sub base of floors, finished the surface even and rough complete all as specified and directed.
M&L for Virified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick cement plaster in CM 1:6 and finished the surface of plaster rough complete all as specified and directed
M&L for glazed ceramic coloured tiles of size 300x600x8mm thick on vertical surfaces such as skirting, dados and risers to steps etc set and jointed in neat cement slurry and pointed with white cement and coloured pigment to match the tile over and including 10mm thick cement plaster in CM 1:4 and finished the surface of plaster rough complete all as specified and directed
M & L for preparation of new plaster surfaces and applying two coat distemper oil emulsion over 3 mm thick wall care putty on walls as levelling course complete all as specified and directed.
Supplying and laying of 20 mm CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ ceiling or laying in floors complete all as specified
S&F 20 mm bore Brass Elbow for fixing of cpvc pipe
S&F Brass Elbow (3/4 X ½) mm for fixing of cpvc pipe
S&F 20 mm Brass Tee for fixing of cpvc pipe
S&F 20 mm Male Brass Threaded Adaptor (MTA/ MBTA) ) for fixing of cpvc pipe
S&F Wash down water closet (Pedestal pattern) using vitreous China squatting pan of pattern “long pan”, size 580 mm white with ‘P’ or ‘S” trap, front or back inlet and foot rests, any pattern including PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets, Flush pipe of polyethylene of low or high density or PVC 32 mm dia, for low level cistern, Plastic water closet seat, white, recessed bottom pattern and cover and mild steel chromium plated or aluminised hinging device
S&F PVC low level 10 lit capacity valve less syphonic action type flushing cistern with inlet ball valve and handle including brackets complete all as specified and directed
S&F PVC connections of 15mm size with PTMT nuts of 600mm long complete all as specified and directed.
S&F bib taps chromium plated 15mm alloy with crutch or butter fly handle screwed down screwed for iron pipe 15mm bore complete all as specified and directed
S&F15 mm bore angle stop valves cast copper alloy chromium plated screwed down high pressure with crutch or butterfly handle screwed withr iron pipe of union. (Make : Prayag/Jaquar/Cera)
S&F for CP soap dish compete all as specified and directed (Make : Prayag/Jaquar/Cera)
S&F for CP 600 mm long towel rail compete all as specified and directed (Make : Prayag/Jaquar/Cera)
S&F for CP health faucet with 1 mtr flexible tube and hook compete all as specified and directed (Make : Prayag/Jaquar/Cera)
S&F for CP paper holder fixing to wall with ss screw compete all as specified and directed (Make : Prayag/Jaquar/Cera)
S&F 15 mm bore Brass CP wash hand besin mixer for mixing hot & cold water screwed down complete all as specified and directed. (Make : Prayag/Jaquar/Cera)
M&L for 75mm dia of outlet, PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed.
S & F 75 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall/Floor, complete all as specified and directed.
S & F for 75 mm bore PVC (SWR) bends any radius with oval access doors complete all as specified and directed.
S&F 75 mm dia PVC (SWR) junction (single ‘T’) equal or un-equal complete all as specified and directed
S & F 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed.
S & F for 110 mm bore PVC (SWR) bends any radius complete all as specified and directed.
S & F PVC (SWR) vent cowl suitable for 110 mm bore of pipe complete all as specified and directed.
S&F 110 mm dia PVC (SWR) junction (single ‘T’) equal or un-equal complete all as specified and directed
S&F grating dome 100 mm dia of PTMT (minimum weight 25 gms) complete all as specified nad directed.
Taking down of chowkhat or frame (without taking off shutter from frame) area not exc 1.50 Sqm each including builder hardware fitting complete all as specified and as directed.
All as per item No 54 here in Before but area exc 1.50 Sqm & not exc 4.00 Sqm each complete all as specified and as directed.
S&F solid PVC moulded door frame of size 50x47mm, made out of 5mm thick one side prelaminated and other side plain colour PVC sheet & edges will be painted to match with prelaminated sheet, reinforced with MS square tube fixed with screw/plugs to brick walls complete all as specified and as directed.
S&F Factory made Solid PVC Moulded Door Shutter 28 to 30mm thick (stiles), with 2, 4 or 6 raised panel design with 2mm thick Moulded Prelam PVC Sheet on the front face & 2mm prelam PVC Sheet on back face, supplying & fixing in frame at site as per specification & drawing, supplying & fixing in the frame at site as per specification & drawing complete all as specified and as directed.
S&F 100mm size, stainless steel butt hinges, fixed with Stainless steel screws complete all as specified and as directed.
S&F 200 mm long aluminium anodised barrel tower bolts of extruded section complete all as specified and as directed.
S&F 150mm size extruded aluminium alloy handles, cast type anodised complete all as specified and as directed.
S&F of 4 mm thick Aluminium Composite panel cladding of approved quality and colour as approved by GE,fixing in MS frame at any height and including MS frame of size not exc 0.36 sqm (used in rect angular tubes of size 50.8mmx 25.4mm x 2.9mm thick or square tubes 38mm x38mm x 2.9 mm thick are used in frame) and filling the joints with all weather silicon sealant including all mouldings, cuttings, etc complete all as specified and directed (Make -ACP Aluedecor,Alstrong,Wonder alu Board over seas,VIVA and Eurobond
M&L for roof treatment with polymeric membrance (APP based) with non woven polyster mat as reinforcement with following:- (a) M&L for cleaning the new plastered surface and providing & laying a coat of cold applied bitumen 85/25 based primer on entire surface @ 0.30 Ltr/Sqm on dry and clean surface. (b) M&L for providing & laying APP based polymeric membrane of 3 mm thickness of weight not less than 3.0 Kg/Sqm with non woven polyster fibre as reinforcement on primed surface by torch application with 15 cm end over laps & 10 cm side over laps etc as per manufacturers instruction.(Make:- SNL ltd ,STP Ltd or Choksy chemical pvt ltd) (c) M&L for finishing of top surface by applying two coats of aluminium paint complete all as specified and directed.
Cutting grooves 75 mm wide & 65 mm deep in brick wall/ RCC surfaces at any location shaping horizntal face with mechanical cutter and grooves filled with PCC 1:2:4 type B-0 (using 12.5 mm gradded stone aggregate) mixed with chemical compound SUPER LATEX OR DR FIXIT OF PIDILITE INDUSTRIES LTD or SBR LATEX of STP LTD mixed with proportion 200 ml per 50 kgs cement as per manufactures instruction all as specified & directed.
M & L for washed stone grit plaster on exterior walls in two layers, under layers 12 mm thick cement plaster 1:4 (1 cement :4 coarse sand) following the under layer with scratching tool, applying cement slurry on the under layer @ 3 Kg of cement per square metre, top layer with 15 mm thick cement plaster 1:1/2:2 (1 cement: 1/2 coarse sand:2 coloured marble stone chipping 10mm nominal size) in panels with groove all around as per approved pattern including scrubbing and washing the top layer with wire brushes and water to expose the stone chippings complete all as specified and as directed.
M&L for forming groove of uniform size 15mm wide and 15mm deep in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repair to the edges of panels and finishing the groove complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 M wide and not exceeding 1.5 M in depth for foundation etc or for shafts, wells, cess pits, manholes, pier holes etc not exceeding 10 Sqm on plan and not exceeding 1.5 M in depth and getting out in soft/loose soil.
Removing of excavated materials to a distance not exceeding 50 M and deposing where directed at a level not exceeding 1.5 M above the starting point
Returning filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm in soft/loose soil
M&L RCC M-25 design mix using 20 mm graded stone aggregate as in foundation, including rafts, footings, foundation beams, plinth beams, bases for columns, etc, basement slab, under reamed piles and mass concrete.
M&L RCC M-25 design mix using 20 mm graded stone aggregate as in Columns, pillars, piers, posts and struts
M&L RCC M-25 design mix Using 20 mm stone aggregate as in Beams, cantilevers, bressummers, lintels over 1.5m span complete.
M&L RCC M-25 design mix Using 20 mm stone aggregate as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves etc complete.
M&L for mild steel 10 mm dia tmt bar and over as in reinforcement cut to length, bent in shape required including cranking, bending, spirally hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips etc.
Description all as per item No 73 above but mild steel tmt bar 6mm to 8 mm dia.
Use and waste of formwork to sides of concrete foundations, plinth beams, footings, base of columns, pile caps and similar work, vertical or to batter, complete all as specified and as directed for rough finished surfaces
Use and waste of formwork to sides of concrete pillars, post, struts, piers, columns and similar work, square, rectangular or polygonal rough finished complete all as specified and as directed.
Use & waste Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, Chhajja, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc.
Use & waste Formwork to soffits of suspended slabs such as roof slabs,flat, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) fair finished complete.
Use & waste formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide complete.
S&F1000 litres capacity rotational moulded polyethylene water storage tanks triple layer (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I including one 20mm ball brass valve with polythene float and fly nut complete all as specified and directed.
S&F stop/Gate valves, cast copper alloy, screwed down, high pressure with crutch or butter fly handles, screwed both ends for iron pipe 20 mm dia, fixed complete all as specified and directed
S&F 15 mm bore tubes medium grade galvanised with all fittings and fixed to walls, ceilings or laid in floors complete all as specified and directed
Description all as per item No 82 above but 20 mm dia
Taking down carefully copper/ aluminium point wiring (light, fan, socket or power) complete (fitting such as switches, ceiling roses, pendent, regulator socket etc to be measured separately) and making good disturbed surfaces of wall floor etc complete all as specified and directed.
Taking down old and unserviceable sub main wiring and removing from the site and making good the disturbed surface complete all as specified and directed.
M&L point wiring for modular switches with 1.5 Sqmm, single core, multistranded copper conductor PVC insulated and unsheathed (FRLS) cable 1100 Volts grade, drawn through concealed conduit 25mm as requirement of site incl cadmium plated screws as per ISI, size PVC insulated un-sheathed copper earth condinuity conductor to common earth and connecting to earth dolly for one light/ bell point controlled by one switch 5 Amps one way single pole complete all as specified and as directed by Engr-in-Charge.
All as per item No. 88 above but one fan point controlled by one switch 5 Amps one way single pole.
All as per item No. 88 above but one three pin 5 Amps socket out let on independent board.
All as per item No. 88 above but one three pin 5 Amps socket out let on same board.
All as per item No. 88 above but point wiring of copper cable multi stranded 2.5 Sqmm size for 15 Amps socket outlet on independent board with 2.5 Sqmm size of earth conductor complete all as specified and directed.
All as per item No. 88 above but point wiring of copper cable multi stranded 4.00 Sqmm size for AC point wiring with 4.0 Sqmm size of earth conductor complete all as specified and directed.
S & F Ceiling rose, PVC/ polycarbonate, isolated body type three terminal, 240 volt complete all as specified and directed.
S&F Modular switch piano , flush button type , single pole , one way 10 Amps complete all as specified and directed.
S&F Modular switch piano , flush button type , single pole , one way 15 amps complete all as specified and directed.
S&F Modular socket outlet 3 pin and 2 pin , 10 amps , flush type complete all as specified and directed.
S&F Modular socket outlet 2-in-1, 3 pin, 10 and 20 amps , flush type complete all as specified and directed.
S&F Fan step regulator, 120W - 2 module suitable for ceiling fan complete all as specified and directed
S&F for Modular Bell push 6A 1 module,
S&F Bell ding dong, AC, 230 Volts, fixed in position & connecting complete all as specified and as directed. Make:- Anchor, Wipro
S&F Lamp holder, white Polycarbonate body, with back plate suitable for batten fittings fixed in position & connecting complete.Make :- Anchor, Cona, Legrand
M&L for sub main wiring with 2 runs of 4 sqmm FRLS single core, PVC insulated & unsheathed cable 1100 Volts grade with multi stranded, copper conductor drawn through concealed conduit including PVC rigid conduit 25mm medium grade with all fittings fixed to the surface of walls/ ceiling as per ISS and one run of 4 sqmm FRLS earth wire size PVC insulated copper conductor complete all as specified and directed.(Note. Two run of cable and earth conductor with conduit shall be measured as one length).
M&L for sub main wiring with 2 runs of 10 sqmm FR single core, PVC insulated & unsheathed cable 1100 Volts grade with multi stranded, copper conductor drawn through concealed conduit including PVC rigid conduit 32mm medium grade with fittings as per ISS and one run of 10 sqmm FR size earth wire PVC insulated copper conductor complete all as specified and directed. (Note Two runs of 10 sqmm copper cable & one run of 10 sqmm copper cable in and including 32 mm PVC conduit medium grade will be measured as one unit.
S & F in repair for distribution board double door type, SPN, 12 way, complete including 200 Amps rated bus bar, neutral link, blanking plates etc complete all as specified and directed.
S & F in repair for load line distribution board double door type, TPN, vertical, 4 way, complete suitable for accomodating upto 125 Amps MCCB with incomming frame three pole , including bus bar, neutral link, blanking plates etc complete all as specified and directed.
S & F MCCB 415 V, 125 Amps, 36 KA, 4 Pole complete all as specified and directed.
S & F MCB DP, 240 Volts, 40 Amps complete all as specified and directed.
S & F MCB DP, 240 Volts, 63 Amps complete all as specified and directed.
S & F MCB SP, 240 Volts, 10 Amps complete all as specified and directed.
S & F MCB SP, 240 Volts, 16 Amps complete all as specified and directed.
S & F MCB SP, 240 Volts, 32Amps complete all as specified and directed.
S & F MCB SP, 240 Volts, 63 Amps complete all as specified and directed.
S&F in repair Bldg security light fitting LED 45 Watt cast aluminium housing, toughened glass,silicon gaskect, high power LED with lens for uniformed distribution pre-wired and electric connection with suitable size of stranded copper flexible PVC insulated wire including GI bracket light grade 1.5 Mtr, 40 mm dia with clamps and bolts complete all as specified and directed.
Material and labour for earthing complete with GI earth plate electrode 600mm x 600mm x 6mm thick buried directly in ground not less than 2.25 mtrs below ground level with top edge of plate not less than 1.5 mtr deep below normal ground level connected to galvinised earth wire 4 mm by means of nuts, bolts and check nut to earth plate and to main board or DB including necessary PCC 1:2:4 type B-1 pit, cover frame , GI pipe 15 mm dia light grade for protection and GI pipe 20 mm dia medium grade for watering with funnel, wire mesh, salt and charcoal dust all over the plate all as specified and as directed.
S&Fmodular white cover plate with frame , 1/2 module.
S&F modular white cover plate with frame , 3 module.
S&F modular white cover plate with frame , 4 module.
S&F modular white cover plate with frame , 6 module.
S&F modular white cover plate with frame , 18 module.
S&F metal flush box 1/2 module. Make: Legrand/Anchor/Indo Asian
S&F metal flush box 3 module. Make: Legrand/Anchor/Indo Asian
S&F metal flush box 4 module complete all as specified and directed. Make: Legrand/Anchor/Indo Asian
S&F metal flush box 6 module complete all as specified and directed. Make: Legrand/Anchor/Indo Asian
S&F metal flush box 18 module square type. Make: Legrand/Anchor/Indo Asian
Supplying, installation, testing & Commissioning in repair of recessed Type Full window opal Diffuser Ultra modern recess mounting LED Panel 2x2of not more than 36W, size 595X595x65mm (Nominal) suitable for Existing false ceiling with CRCA powder coated White Housing & Isolated Electronic Driver with Output Short-circuit protection, Surge Voltage protection min 3KV, safety & performance test as per IS:15885 Part 2/Sec 13. Total system Lumen not less than 4200 in Cool day Light(5700K), Power factor>0.95, CRI (Ra) >80 with Average life of 50000 Burning hours. Complete with all accessories as required with connections. Make - Havells cat part No. - PLANO2X2PLR36WLED857S /Polycab/CG
Supplying, installation, testing & Commissioning in repair of Surface/Wall Mounted 10W integrated LED 2 feet Fitting with Epoxy powder coated white polycarbonate channel housing. Total system Lumen of 10W Led should be 800 or above in Cool day Light(6500K), Power factor>0.95, CRI (Ra) >80, System Lumen Efficacy>100 Lm/w, THD(%) < 20, Complete with all accessories as required with connections. Make - Havells cat part No -LUMILINEBS10WLED865SPCWH/ Polycab/CG
Supplying, installation, testing & Commissioning in repair of Surface/Wall Mounted integrated LED 4 feet Fitting of not more than 20w with polycorbonate housing & opal diffuser finish , Integral electronic driver with Output short circuit protection, Surge Voltage Protection of min 3 KV and Safety test as per IS15885 Part 2/ Sec 13. Total system Lumen not less than 2000 or above in Cool day Light(6500K), Power factor>0.95, CRI (Ra) >80, System Lumen Efficacy100 Lm/w, THD(%) < 20, LED with Average life of 50000 Burning hours. Complete with all accessories as required with connections. All above mentioned Specs will be verified through NABL Certified LM79 & LM80 Report before supply of LED Fixture on site. Make - Havells cat part No -LUMILINEBS20WLED865SPCWH/Polycab/CG
S & F in repair sheet metal enclosure with socket plug top single pole, neutral enclosure with a two pin earth plug, socket complete with one MCB of Cap 25 Amps, 240 V complete all as specified and directed. Make - Havells/ Legrand/ABB.
Supply and Fixing in repair of five star rated Geysers of cap. 25 Ltr, Electric Driven, Single phase, 240 V, Storage vertical type and heating element 2 KW, inner shell made up of copper, automatic cutoff , including electrical and water connection with hot and cold water connection pipe (PVC type) and fixed on the wall with mild steel fastner 150 mm long and 10 mm dia with pin and bolts complete all as specified and directed. Make: HAVELLS/RECOLD /BAJAJ Note :- Old unserveciable Geyser will be deposited to MES store yard.
S&F in repair BAHAR Metallic grey exhaust fans of size 300 mm sweep AC single phase 230/240 v , RPM 1375 , Power 42 watt, with louver, fixed as per manufacturer instruction, connecting with and including 1.5 Sq mm copoer conductor, PVC insulated and PVC sheathed three core cable including making suitable size hole in brick/PCC block/ Stone masonary wall built in cement mortar and making good disturbed surface complete as as specified and directed by Engr-in-Charge . Make: BAHAR 300 MM METALLIC GREY EF/ Havells/CG Note :- Old unserveciable exhaust fan will be deposited to MES store yard.
M/S Rohit Enterprises
HANUMAN BUILDERS
R R Associates
RV. Enterprises
MAA SANTOSHI ENTERPRISES
POONAM ENTERPRISES
The new hut furnitures
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .