Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.8 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹31.3 L+₹7.0 L (28.7%)Rejected-AOC 1 TROPICAL REFRIGERATION PHONIX BAY PORT BLAIR PORT BLAIR ANDAMAN NICOBAR 744101 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744101 | L2 | Rejected-AOC Being not L1 | |
| 3 | L3₹35.8 L+₹11.5 L (47.3%)Rejected-AOC | L3 | Rejected-AOC Being not L1 | |
| 4 | L4₹36.8 L+₹12.5 L (51.4%)Rejected-AOC | L4 | Rejected-AOC Being not L1 | |
| 5 | L5₹38.6 L+₹14.3 L (59.1%)Rejected-AOC | L5 | Rejected-AOC Being not L1 |
Tender Value
Refer Docs
EMD Value
₹69,600
Closing Date
16 Dec 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Col PS Chand, CWE
Commander Works Engineer Military Engineer Services Minniebay Junglighat Post Port Blair
Rep Maint of AC Plats Central AC plants and Package type AC plants INS Utkrosh NTS Teylerabad and Dollygunj of AGE EM-2 Under GE Minniebay
2020_MES_395780_1
80906 Rep Maint AC Plants GE Minniebay
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
Garrison Engineer Minniebay Port Blair
As per NIT
8 documents required · 8 mandatory
₹500
Garrison Engineer Minniebay
₹69,600
Yes
21 Jan 2021
17 Nov 2020
22 Dec 2020
17 Nov 2020
16 Dec 2020
2 Dec 2020
60 days
Amount
Overhauling of compressor 22.5 TR complete including taking down unserviceable parts and refixing new parts where ever necessary complete all as directed by Engr-in-Charge after the pumping down the complete system and collecting the refrigerant into condenser, compressor oil into clean container, disconnecting the compressor from suction & discharge side and including leak testing of compressor after reassembling the parts, recharging/filling retrieved oil & gas, replacement of belt if required and testing upto satisfactory cooling performance complete all as specified and as directed. Make: ACCEL compressor.( UTK) Note: (i) spare parts , refrigerant (gas) & compressor oil for top up if required shall be measured and paid for separately as supply only in respective item of this schedule. (ii) Metal filling , grinding, polishing spring, washer, quarter, and consumable items such as grease cotton waste etc., are deemed to be included in the quoted rate. (iii) Belt shall be paid separately as supply only.
Overhauling of compressor 36TR complete including taking down unserviceable parts and refixing new parts where ever necessary complete all as directed by Engr-in-Charge after the pumping down the complete system and collecting the refrigerant into condenser, compressor oil into clean container, disconnecting the compressor from suction & discharge side and including leak testing of compressor after reassembling the parts, recharging/filling retrieved oil & gas, replacement of belt if required and testing upto satisfactory cooling performance complete all as specified and as directed. Make: Bock compressor.(NTS) Note: (i) spare parts , refrigerant (gas) & compressor oil for top up if required shall be measured and paid for separately as supply only in respective item of this schedule. (ii) Metal filling , grinding, polishing spring, washer, quarter, and consumable items such as grease cotton waste etc., are deemed to be included in the quoted rate. (iii) Belt shall be paid separately as supply only.
M&L for repair to suction & discharge valve of compressor 22.5 TR & 36 TR of capacity by means of replacing the teflon washer sheet, suction & discharge valve ring, spring, 'O' rings, gaskets etc complete and testing for proper holding of valve, leak testing etc all as specified and as directed. make: ACCEL compressor & BOCK compressor. NOTE: The rate inclusive of suction & discharge valve which is considered as one job.
M & L for descaling the shell & tube condenser of 20 to 36 TR capacity at by circulating the descaling chemical (scale gun) (HCL acid) through condenser by pressure feeding method after disconnecting condenser water lines, and opening the end covers of both side, brushing condenser water tubing, removing the scales, normalising the copper surface circulation normalising agent and refixing all dismantled parts including replacement of gasket set all as specified .
M & L for leak testing of AHU unit cooling coil after pumping down the complete system, isolating the cooling coil from both ends and charging the dry nitrogen gas for pressure leak test, after detecting leak point, release the nitrogen gas, repairing the leak point but means of soldering/brazing and connecting the cooling coil with system, vaccumised the complete system and re-charge the system by refrigerant, testing and commissioning up to satisfactory cooling performance of 45 & 72TR capacity. Note: (i) Refrigerant gas shall be measured and paid separately as supply only. (ii) Nitrogen gas required deemed to be inclusive in the quoted rate.
M & L for leak testing of AHU unit cooling coil after pumping down the complete system, isolating the cooling coil from both ends and charging the dry nitrogen gas for pressure leak test, after detecting leak point, release the nitrogen gas, repairing the leak point but means of soldering/brazing and connecting the cooling coil with system, vaccumised the complete system and re-charge the system by refrigerant, testing and commissioning up to satisfactory cooling performance of 16 TR capacity. (INS UTK) Note: (i) Refrigerant gas shall be measured and paid separately as supply only. (ii) Nitrogen gas required deemed to be inclusive in the quoted rate.
M & L for leak testing of AHU unit cooling coil after pumping down the complete system, isolating the cooling coil from both ends and charging the dry nitrogen gas for pressure leak test, after detecting leak point, release the nitrogen gas, repairing the leak point but means of soldering/brazing and connecting the cooling coil with system, vaccumised the complete system and re-charge the system by refrigerant, testing and commissioning up to satisfactory cooling performance of 10 TR capacity. (INS UTK) Note: (i) Refrigerant gas shall be measured and paid separately as supply only. (ii) Nitrogen gas required deemed to be inclusive in the quoted rate.
M&L for Cleaning / servicing the cooling coil of AHU AC plant by pressure air method with using air blower and cleaning the cooling coil with cleaning the solution, cleaning the AHU base tray completely and applying one coat of synthetic enamelled paint inside the base tray, including greasing to AHU blower shaft bearing for smooth functioning, cleaning the AHU filter replacement of V-belt ( if required) of 45 & 72 TR plant capacity complete all as specified and as directed.
S & F in Replacement of panel air filters, dry type, washable, rated air flow capacity 1600 CFM 99.9%, down to particle 20 micron of Suitable sizes or nearest for AHU of central AC plant.(NTS,NAD UTKROSH)
M&L for pumping down the gas of the Package type AC plant of various capacities pressure testing the complete plant by dry nitrogen gas by separating high side and low side, rectifying the leakage by gas welding brazing pressure testing vacuuming the system and re-charging the system with gas, testing and commissioning complete.(INS UTK & NAD) Note:- (i) Nitrogen gas required are deemed to include in the quoted rate. (ii) Refrigerant gas shall be measured and paid separately as supply only.
Cleaning / servicing the cooling coil of AHU AC plant by pressure air method with using air blower and cleaning the cooling coil with cleaning the solution, cleaning the AHU base tray completely and applying one coat of synthetic enamelled paint inside the base tray, including greasing to AHU blower shaft bearing for smooth functioning, cleaning the AHU filter replacement of V-belt (if required) of 16 TR plant capacity at INS UTK & NAD all as specified .
Supply & Fixing compressor in replacement for up to 8.5 TR capacity package type AC plant including mounting brackets , clamps, nut, bolts and necessary electrical connections all as specified and directed
Cleaning / servicing the cooling coil of AHU AC plant by pressure air method with using air blower and cleaning the cooling coil with cleaning solution, cleaning the AHU base tray completely and applying one coat of synthetic enamelled paint inside the base tray, including greasing to AHU blower shaft bearing for smooth functioning, cleaning the AHU filter replacement of V-belt (if required) of 10 TR plant capacity at INS UTK & all as specified .
M&L for pumping down the gas of the Central AC plant of various capacities pressure testing the complete plant by dry nitrogen gas by separating high side and low side, rectifying the leakage by gas welding brazing pressure testing vacuuming the system and re-charging the system with gas, testing and commissioning complete.(INS UTK & NTS )
Cleaning/servicing of cooling tower, natural draught type of central AC plant including cleaning of wooden louvers by scraping inside and outside, cleaning of water tank, cleaning of nozzles (brass/PVC) , arranging all wooden louvers in correct manners, and applying one coat of bituminous paint inside and outside of water tank complete of capacity 45 & 72 TR complete all as specified and as directed.
supply and fixing of PVC spray nozzles 20 mm size for cooling tower as per sample.
supply and fixing of PVC spray nozzles 25 mm size for cooling tower as per sample.
Material and labour spray nozzle GI pipe assembly at INS UTK & NTS Cooling tower GI pipe assembly of size 100mm dia medium grade 3 metre long, duly welded with 50 mm sockets-3 Nos,20 mm sockets-8 Nos. and 50 mm branch pipes-(two metre each )-3 Nos with welding of 20 mm sockets -24 Nos. by cutting with gas cutter and welding with GI welding rods including supply and fixing of 20 mm dia medium grade GI pipe nipples-30 cm long -32 Nos complete all as directed.
M&L for preparation of old painted steel surfaces and applying two coats of synthetic enamelled paint to external surfaces to compressor with motors - 03 No's, foundation of compressor & motor units- 03 No's, suction & discharge refrigerant pipe line, condenser water pump with motor & foundation - 02 No's, water pipe line, AHU unit and motor/blower- 01 No, condenser - 03 No's of any capacity of central AC plant. (INS UTK & NTS)
M & L for dismantling burnt out three phase, 50 C/S capacity 20/25 HP motor for rewinding with same gauge, weight and same number of turns of super annealed copper wire including paper/tape of approved quality and varnishing with Class I varnishing compound including heating and re-assembling the motor, testing and commissioning after repair including replacement of worn out bearing complete all as specified. NOTE for Sl item No 20 and 27:-Bearing shall be measured and paid for separately as supply only under respective items of this schedule.
All as per item No.20 above but motor capacity 12.5 HP.
All as per item No.20 above but motor capacity 10 HP.
All as per item No.20 above but motor capacity 7.5 HP.
All as per item No.20 above but motor capacity 5 HP.
S & F in replacement of `V' belt size B-78.
S & F in replacement of `V' belt size A-32.
M&L for dismantling Monoblock pump set up to 10 HP removing scales cleaning, heating varnishing of motor winding, servicing the pump sets by replacing the worn out bushes, bearings, gland rope, gland bolts & nuts, and applying two coats of synthetic enamel painting etc reassembling the complete pump set including testing and commissioning and replacement of worn out bearings complete all as directed by Engineer - in - Charge.
S & F in replacement of pressure gauge of HP size 4" dia of rating 0 - 300 PSI all as specified .
S & F in replacement of water pressure gauge of 4 " dia of range 0 - 7 Kg /sqcm or 0 - 100 PSI all as specified
S & F replacement of pressure gauge of LP OP (low pressure /oil pressure) size 4" dia of rating -30 to 150 PSI all as specified
S & F in replacement of HP cut out Type MP - 5 suitable for R - 22 gas complete all as specified and as directed.
S & F in replacement of LP/HP combination cut out MP - 15 Suitable for R 22 gas complete with flare nut complete all as specified and as directed.
S & F in replacement of oil pressure control switch type MP - 55 suitable for R - 22 complete with flare nut complete all as specified and as directed..
S & F in replacement of solenoid pilot control valve type 10 with two / three coil assembly of same model all as specified. (INS Utkrosh & NTS, NAD)
Supply only synthetic refrigeration compressor oil suitable for 36TR compressor.
Supply only compressor oil N 68 sheetal suitable for ACCEL compressor of capacity 22.5 TR
S&F in replacement of thermostatic expansion valve of model MWE - 34 - CP 100 of Make - SPORLAN all as specified.(INS UTK & NTS, NAD)
Supply only refrigeration gas R 22 in manufacturer sealed cylinder. NOTE:- (i) Gas to be supplied in manufacturer sealed container. (ii) Empty containers will be returned to contractor .
Replacement of 6/10 mfd condensor suitable for cooling fan motor of outdoor unit of package AC plant 5 TR capacity(INS UTK)
Replacement of 20 mfd condensor suitable for cooling fan motor of outdoor unit of package AC plant 8.5 TR capacity
Replacement of 20 mfd condensor suitable for cooling fan motor of outdoor unit of package AC plant 10 TR capacity(INS UTK)
S & F in replacement of condensor fan motor 1/5 HP single phase complete for 5 TR package AC plant .
S & F in replacement of condensor fan motor 1/5 HP single phase complete for 8.5 TR package AC plant .
S & F in replacement of condensor fan motor 3/4 HP single phase complete for 10 TR package AC plant .
S & F in replacement of condensor fan motor 3/4 HP single phase complete for 16 TR package AC plant .
S & f in replacement of micro computer control with PCB complete for package AC unit 5 to 16 TR.
Supply only bearing suitable for 25 HP three phase motor .
Supply only bearing suitable for 20 HP three phase motor .
Supply only bearing suitable for 10 HP three phase motor .
Supply only bearing suitable for 7.5 HP three phase motor
Supply only bearing suitable for 5 HP three phase motor
Supply only bearing suitable for 3 HP three phase motor
Supply only bearing suitable for 1 HP three phase motor
Supply only threaded flanged joints suitable for 80/100mm bore GI pipe.
Supply only sump heater assy Cat No. 8426 Make. Bock
Supply &fix in replacement of glow sign/Name board for installation in front of installation with SS pipe for standing pipe of 25mm/40mm of suitable height, with appropirate stickring on the board, the colur of letters and backgroung as directed by Eng-In-Charge
Supply & fix replacement of power contactor MNX 45 Make: L&T
Supply & fix replacement of power contactor MNX 25 Make: L&T
Supply & fix replacement of power contactor MNX 18 Make: L&T
Supply & fix of electronic type star delta starter fully automatic suitable for 10 HP water coolant motor. Make: L&T all as specified & directed.(NTS)
S& F in replacement of current convertor at starter panel type CTS 80 Amps suitable for 36 TR all as specified & directed. Make : Minic
S& F in replacement of current convertor at starter panel type CTS 40 Amps suitable for 22.5 TR all as specified & directed. Make : Minic
S& F in replacement of current convertor at starter panel type CTS 20 Amps all as specified & directed. Make : Minic
S & F in replacement of over load relay suitable for 22.5 & 36 TR compressor motor starter all as specified & directed. Make Minic
S & F in replacement of timer 22.5 & 36TR compressor motor starter all as specified & directed. Make BCH
S& F in replacement of earth leakage relay suitable for 22.5 & 36TR compressor motor starter all as specified & directed. Make: L&T.
Supply & fix replacement of MCCB 3-pole 100 Amps with breaking capacity 25 KA MAKE :L&T Thermostatic type , all as specified & directed.
S & F in replacement of timer suitable for upto 7.5 HP motor starter all as specified & directed. Make BCH/ L&T/ Schneider/ C&S
S & F in replacement of timer suitable for 25 HP motor starter all as specified & directed. Make BCH
Supply & fix replacement of MCCB 4-pole 250 Amps with breaking capacity 36 KA Adjustable thermal Magnetic setting Ics=75% of Icu MAKE :L&T Thermostatic type , all as specified & directed.
S & F in replacement of Single Phase Preventer suitable for up to 30Hp motor starter all as specified & directed. Make: Minic
Supply & fix replacement of current transformer 100/5 Amps ratio at main panel all as specified & directed.
Supply & fix replacement of ammeter with ratio of 0-100 Amps & all as specified & directed.
Supply & fix replacement of voltmeter 0-500 V AC supply 50 Hz & all as specified & directed.
Replacement of drier core suitable for 36 TR Central AC plant, all as specified & directed.
Replacement of drier core suitable for 22.5 TR Central AC plant, all as specified & directed.
Replacement of drier core suitable for 16 TR Central AC plant, all as specified & directed.
Replacement of drier core suitable for 10 TR Central AC plant, all as specified & directed.
Replacement of drier core suitable for 5 TR Central AC plant, all as specified & directed.
Supply and fix in Replacement of u/s POP with thermocole At AHU Cooling pipe liquid ,discharged pipe suitable for36/ 22.5 TR Central ac plant, all as specified & directed.
Supply & fix replacement of MCB TPN 40 Amps 440 V 50Hz all as specified & directed.
Supply and fixing Electrical wiring of panel with suitable 1.5 Sq.mm/2.5 Sqmm (nominal area) PVC unsheathed multi stranded copper conductor pvc insulated 1100 volt FRLS grade single core cable, testing and commissioning of complete power system including fixing of conductor, timer, overload relay, earth leakage relay, MCCB, servicing of starter etc.satisfacotry operation of the AC plant of capacity 22.5TR all as specified and directed. Note:- Additional spare parts measured and paid separately
S & F in replacement of MCCB 4 pole 63 to 100 Amps with breaking capacity 18 KA Make: L&T adjustable type
M&L for repairing existing LT panel dismantling all damaged doors . Hinges and repair & replacement of all damaged doors .with new nut bolt and washers refixing in the same place properly with painted and applying two coats of synthetic enamelled paint to external & internal surfaces all as specified
Supply only Gasket Set for compressor SMC 6-65 make ACCEL.
Supply only Half section of bearing standard (0.25/0.50) for compressor SMC 4-65/ 6-65 make ACCEL.
Supply only Piston ring standard size for compressor SMC 6-65 make ACCEL.
Supply only Scrapper ring standard size for compressor SMC 6-65 make ACCEL.
Supply only Seegar ring standard size for compressor SMC 6-65 make ACCEL.
Supply only Suction valve retaining plate for compressor SMC 6-65 make ACCEL.
Supply only discharge valve retaining plate for compressor SMC 6-65 make ACCEL.
Supply only Piston standard size for compressor SMC6-65 make ACCEL.
Supply only Oil regulating valve for compressor SMC 6-65 make ACCEL.
Supply only Bush for piston pin for compressor SMC 6-65 make ACCEL.
Supply only Piston pin for compressor SMC 6-65 make ACCEL.
Supply only Rocket arm spring for compressor SMC 6-65 make ACCEL.
Supply only oil pump assembly for compressor SMC 6-65 make ACCEL.
Supply nly Teflon washer for suction valve for compressor SMC 6-65 make ACCEL.
Supply only Teflon washer for Discharge valve for compressor SMC 6-65 make ACCEL.
Supply only of Circlips collar pins for compressor SMC 6-65 make ACCEL.
Supply only Unloading cylinder for compressor SMC 6-65 make ACCEL.
Supply only Crankshaft assembly for compressor SMC 6-65 make ACCEL.
Supply and fixing Expansion valve for 5.5 TR condensor Make : Danforce
Supply and Fixing in replacement fan blade for 5.5 TR condensor Make : Danforce
supply and fix PC Board assembly suitable for 16 TR package AC Make : Blue star
Supply and Fixing in replacement of Air cooled condensor out door type with tank and copper tube for discharge line unit assembly including contactor capacitor suitable for capacity 5.5 to 8.5 TR all as specified and directed Make: Blue star
M & L for disconnecting , removing of 3 HP motor form package type AC carry out to workshop for repairing/ rewinding , brushing Cleaning and replaced necessary required items , refixing in the same position with out damage all as specified and as directed by Eng-in-Charge.
Supply and fixing canvas for suitable for 10/16 TR package type AC duct as sample approval .
Supply& fixing in replacement shaft seal assy including connected accessories etc. compressor SMC 6-65 make ACCEL complete all as specified and directed.
M&L for repair maintenance of wooden cooling tower of capacity 45/80 TR, replacement of old unserviceable wooden louvers blanks (1mtr x 0.30 mtr x 0.8mm) = 30 Nos with wooden base support, corner chouket and applying one coat of bituminous paint inside and outside of cooling tower water tank complete all as specified and as directed.
S & F in replacement of MCCB 4 pole 400A, 36kA breaking capacity Adjustable thermal Magnetic setting Ics=75% of Icu MAKE :L&T Thermostatic type , all as specified & directed. (as incoming)(NTS)
M&L in repairs for butterfly valve, both ends flanged and drilled with disc of DI with epoxy coating or CI with nylon coating and duly sealed with neoprene rubber / EPDM, of class PN-1.6, ISI marked complete all as specified and as directed of sizes 100 mm bore complete all as specified and as directed.
M&L in repairs for fire dampers made out of GI section with 16 SWG GI sheet with UL stamped fusible link duly operated with stainless steel spring and provided in main supply duct to cut off in case of fire, etc. complete all as specified and as directed by Engineer- in- charge.
M&L for GI duct dampers with extruded aluminium sections for volume control complete all as specified and as directed by Engineer- in- charge.
M&L for Brick work with sub class 'B' bricks straight or curved on plan exc 6m mean radius built in cement mortar 1:6, complete all as specified and as directed
M&L for cement concrete in foundation type C2 ,1:3:6 using 40mm graded stone aggregate all as specified and as directed by Engineer-in-Charge.
M&L for 10mm thick cement plastering in cement mortar 1:6 on brick work or concrete surfaces finished even & smooth without using extra cement complete all as specified and as directed
Tropical Refrigeration
MGP Enterprises
M/s Karbhagam Sales Agency
EVEREST COOLING WORKS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .