GEMC-511687718669918
Awarded to secutronics
₹1.4 L
Products
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| SOLAR WATER HEATING SYSTEM | SUPREME SOLAR 500 LPD ETC | - | 1 NOS | ₹1.4 L | 140,000 |
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹1.4 LQualified Make: Supreme Solar
Model: SUPREME SOLAR 500 LPD ETC 6 SHOP POLYTECHNIC SQUARE GANDHI BHAWAN ROAD BHOPAL SHYAMLA HILLS BHOPAL MADHYA PRADESH 462002 | BHOPAL | MADHYA PRADESH | 462002 | Make: Supreme Solar
Model: SUPREME SOLAR 500 LPD ETC | ₹1.4 L | L1 | Qualified |
| 2 | Disqualified Make: Supreme Solar
Model: SUPREME SOLAR 500 LPD ETC 4 66 NETAJI SUBHASH SADAN PLOT NO 4 66 SEC 2 RAJENDRA NAGAR RAJENDRA NAGAR GHAZIABAD UTTAR PRADESH 201005 | GHAZIABAD | UTTAR PRADESH | 201005 | Make: Supreme Solar
Model: SUPREME SOLAR 500 LPD ETC | - | - | Disqualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
12 Aug 2018, 9:00 amClosed
solar water heating system Experience with Gov. Required 2 Year (s) Solar Water Heating System ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Conformity to standards for Solar water Heating System -Code for Acceptance IS:12976:1990 with latest amendment - BIS Approved Yes Yes If Yes
Mention CM/L No. otherwise write NA 6200092699 - Model Number of Solar Water Heater System 500 LPD - Solar water Heating System Compatibility with Heat Exchange Solar water Heating System with Heat Exchanger Solar water Heating System with Heat Exchanger Region Type 2 Warm (Areas where ambient temp. is moderate and do not normally below 5 Deg. C - Rated Capacity in Litres per Day (LPD) 500 500 Warranty (Years) 5 Years 5 Years CONSTRUCTIONAL Aperture area of collector
Sq. 3.6 3.6 1/6 Meteres (Sq Meter) Electrical Heater ( Back up ) Capacity (kw) 2 2 Capacity of Make up tank( SWHS with Heat Exchanger only ) (Ltrs) 5.0 5.0 Solar Flat Plate shall be BIS marked and as per IS :12933/2003 with amendment 1 to 3 Yes - Type of Cover Plate conforming to IS 12933/2003 Made up of Toughened Glass with thickness 4.00 mm minimum Made up of Toughened Glass with thickness 4.00 mm minimum Solar Transmittance for cover plate at normal Incidence (%) 82 - Material for Collector Box Aluminium Aluminium Numbers of collectors 4 - Minimum Channel Section Thickness for sides ( For Al based) >/= 1.4 mm for aluminium based - Minimum Thickness of Sheet for Bottom ( For Al based) >/= 0.45 mm for aluminium based - Minimum Thickness of Sheet used as Support for Glass retaining ( For Al based) >/= 1.2 mm for aluminium based - Thickness of Sheet for entire body >/= 1.0 mm for aluminium based - CRCA Material Thickness >/= 0.91 mm for CRCA - Riser and Header assembly designed for working pressure Riser and Header assembly designed for working pressure 24.5 k pa tested for leakage at a minimum hydraulic pressure of 490 K pa - Number of absorber sheets per collector 9 - Numbers of Header Tubes 9 - Numbers of Riser Tubes 9 - Diameter of Header Tube (mm) >/= 24.5 mm - 2/6 Thickness of Header Tube (mm) >/=0.71 - Thickness of Riser Tube (mm) >/= 0.56 mm - Material of Riser Header for Absorber Copper Only - Distanace Between Risers from center to center (mm) >/= 120 (mm) - Material of sheet for absorber Copper Copper Collector Box Insulation Back and sides - Thermal Resistance of Insulation in Square Degree for Back Face >/=0.96 W/Km - Thermal Resistance of Insulation in Square Degree for Side Face >/=0.47 W/Km - Gasket and Grommets shall confirm to IS 12933/2003 with latest amdt Yes - Material for Hot water storage Tank SS304 SS304 Name the Material if choose others SILICON RING - Non Pressure Type Hot water Storage Tank Yes - Position of Hot water tank Horizontal - Thickness of sheet of Hot water tank (mm) 2.8 - Hot water Tank Insulation Density ( High density PUF insulation for 32 kg meter cube or higher density (mm) >/=40 - Hot water Welding TIG - Coating Material for Hot water tank Polyster Epoxy Plus Balck Epoxy based Paint - Thickness of Coating (micron) 50 - Tank stand Material Mild Steel - Size of Tank Stand (L x W x H ) Must be Yes - 3/6 Greater Than 38 x 38 x 4 (mm3) Type of Heat Exchanger cage Type - Material for Heat Exchanger Stainless steel Stainless steel Thickness of tube of heat Exchanger
Minimum 22 SWG Yes - Heat Transfer Rate for heat Exchanger Must be greater than 0.24 sq meter per 100 LPD capacity - Numbers of Electrical Heaters ( Back Up Type ) provided 2 2 Collector Stand Material Mild steel - Size of Collector Tank Stand (L x W x H ) Must be Greater Than 38 x38 x 4 (mm3) Yes - System Interconnecting Pipes material G.I Pipes as per IS: 1239 - if other mention the Material for interconnecting pipes GI - Size of interconnecting Pipes (mm) 24 - Tank test Pressure (bar) 5 - System Working Pressure (Bar) 1 - Inlet and Outlet Valve Yes - Temp Gauge( for Hot Water ) Yes - Gun Metal Strainer ( for Cold Water ) Yes - Water Meter Yes - Gasket for Flanges 3 mm thick gasket of neoprene - Electrical Back up Control panel Yes - Make of Control Panel Schneider - if others
mention the make of Control Panel NA - 4/6 Weight of solar water heater system (kg) 150 - CERTIFICATIONS Availability of Test Report as per IS : 6893-6 (1985) used for purcahse specification for Machine Tools
Part 6 Bench/Pillar type Drill Machine with latest amndmt.from Central Govt./NABL/ILAC acredited lab to prove confirmity to specification yes - Test Report No. MKU/RTC/18/206 - Test Report Date 13/09/2017 - Name of the Lab RTC - Address of the Lab MADHUR KAMRAJ UNIVERSITY - Availability of Schematic Drawing Yes - Instruction Manual for installation
Repair and maintanance Yes - test teat1 true - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Ravindra Singh Gaur 462003
Managing DIrector
MP Rajya Pashu Dhan Evam Kukkut Vikas Nigam
New Broiler Bhawan Main Road No 3 Kotra Sultanabad Bhopal 1 15
451592
GEM/2018/B/63844
GeM Contract
solar water heating system
GeM Contract
15 days
Madhya Pradesh; Bhopal
PRODUCT
Awarded to secutronics
₹1.4 L
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| SOLAR WATER HEATING SYSTEM | SUPREME SOLAR 500 LPD ETC | - | 1 NOS | ₹1.4 L | 140,000 |
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| solar water heating system Experience with Gov. Required 2 Year (s) Solar Water Heating System ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Conformity to standards for Solar water Heating System -Code for Acceptance IS:12976:1990 with latest amendment - BIS Approved Yes Yes If Yes | - | - | - |
| Mention CM/L No. otherwise write NA 6200092699 - Model Number of Solar Water Heater System 500 LPD - Solar water Heating System Compatibility with Heat Exchange Solar water Heating System with Heat Exchanger Solar water Heating System with Heat Exchanger Region Type 2 Warm (Areas where ambient temp. is moderate and do not normally below 5 Deg. C - Rated Capacity in Litres per Day (LPD) 500 500 Warranty (Years) 5 Years 5 Years CONSTRUCTIONAL Aperture area of collector | - | - | - |
| Sq. 3.6 3.6 1/6 Meteres (Sq Meter) Electrical Heater ( Back up ) Capacity (kw) 2 2 Capacity of Make up tank( SWHS with Heat Exchanger only ) (Ltrs) 5.0 5.0 Solar Flat Plate shall be BIS marked and as per IS :12933/2003 with amendment 1 to 3 Yes - Type of Cover Plate conforming to IS 12933/2003 Made up of Toughened Glass with thickness 4.00 mm minimum Made up of Toughened Glass with thickness 4.00 mm minimum Solar Transmittance for cover plate at normal Incidence (%) 82 - Material for Collector Box Aluminium Aluminium Numbers of collectors 4 - Minimum Channel Section Thickness for sides ( For Al based) >/= 1.4 mm for aluminium based - Minimum Thickness of Sheet for Bottom ( For Al based) >/= 0.45 mm for aluminium based - Minimum Thickness of Sheet used as Support for Glass retaining ( For Al based) >/= 1.2 mm for aluminium based - Thickness of Sheet for entire body >/= 1.0 mm for aluminium based - CRCA Material Thickness >/= 0.91 mm for CRCA - Riser and Header assembly designed for working pressure Riser and Header assembly designed for working pressure 24.5 k pa tested for leakage at a minimum hydraulic pressure of 490 K pa - Number of absorber sheets per collector 9 - Numbers of Header Tubes 9 - Numbers of Riser Tubes 9 - Diameter of Header Tube (mm) >/= 24.5 mm - 2/6 Thickness of Header Tube (mm) >/=0.71 - Thickness of Riser Tube (mm) >/= 0.56 mm - Material of Riser Header for Absorber Copper Only - Distanace Between Risers from center to center (mm) >/= 120 (mm) - Material of sheet for absorber Copper Copper Collector Box Insulation Back and sides - Thermal Resistance of Insulation in Square Degree for Back Face >/=0.96 W/Km - Thermal Resistance of Insulation in Square Degree for Side Face >/=0.47 W/Km - Gasket and Grommets shall confirm to IS 12933/2003 with latest amdt Yes - Material for Hot water storage Tank SS304 SS304 Name the Material if choose others SILICON RING - Non Pressure Type Hot water Storage Tank Yes - Position of Hot water tank Horizontal - Thickness of sheet of Hot water tank (mm) 2.8 - Hot water Tank Insulation Density ( High density PUF insulation for 32 kg meter cube or higher density (mm) >/=40 - Hot water Welding TIG - Coating Material for Hot water tank Polyster Epoxy Plus Balck Epoxy based Paint - Thickness of Coating (micron) 50 - Tank stand Material Mild Steel - Size of Tank Stand (L x W x H ) Must be Yes - 3/6 Greater Than 38 x 38 x 4 (mm3) Type of Heat Exchanger cage Type - Material for Heat Exchanger Stainless steel Stainless steel Thickness of tube of heat Exchanger | - | - | - |
| Minimum 22 SWG Yes - Heat Transfer Rate for heat Exchanger Must be greater than 0.24 sq meter per 100 LPD capacity - Numbers of Electrical Heaters ( Back Up Type ) provided 2 2 Collector Stand Material Mild steel - Size of Collector Tank Stand (L x W x H ) Must be Greater Than 38 x38 x 4 (mm3) Yes - System Interconnecting Pipes material G.I Pipes as per IS: 1239 - if other mention the Material for interconnecting pipes GI - Size of interconnecting Pipes (mm) 24 - Tank test Pressure (bar) 5 - System Working Pressure (Bar) 1 - Inlet and Outlet Valve Yes - Temp Gauge( for Hot Water ) Yes - Gun Metal Strainer ( for Cold Water ) Yes - Water Meter Yes - Gasket for Flanges 3 mm thick gasket of neoprene - Electrical Back up Control panel Yes - Make of Control Panel Schneider - if others | - | - | - |
| mention the make of Control Panel NA - 4/6 Weight of solar water heater system (kg) 150 - CERTIFICATIONS Availability of Test Report as per IS : 6893-6 (1985) used for purcahse specification for Machine Tools | - | - | - |
| Part 6 Bench/Pillar type Drill Machine with latest amndmt.from Central Govt./NABL/ILAC acredited lab to prove confirmity to specification yes - Test Report No. MKU/RTC/18/206 - Test Report Date 13/09/2017 - Name of the Lab RTC - Address of the Lab MADHUR KAMRAJ UNIVERSITY - Availability of Schematic Drawing Yes - Instruction Manual for installation | - | - | - |
| Repair and maintanance Yes - test teat1 true - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Ravindra Singh Gaur 462003 | - | - | - |
| Managing DIrector | - | - | - |
| MP Rajya Pashu Dhan Evam Kukkut Vikas Nigam | - | - | - |
| New Broiler Bhawan Main Road No 3 Kotra Sultanabad Bhopal 1 15 | - | - | - |
Exempted
24 Aug 2018
8 Aug 2018
contract_GEMC-511687718669918.pdf
GEM_CONTRACT • 0.02 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_451592.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .