Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.5 LAccepted-AOC 306 SHIV BARI MARG PANCHVATI NAGAR BATHINDA 151001 PB | BATHINDA | BATHINDA | PUNJAB | 151001 | L1 | Accepted-AOC L1 | |
| 2 | L2₹4.2 L+₹39,433.90 (10.4%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹4.4 L+₹63,068.65 (16.6%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | L4₹5.8 L+₹2.0 L (53.4%)Rejected-AOC | L4 | Rejected-AOC L4 |
Tender Value
₹8 L
EMD Value
₹16,000
Closing Date
17 Aug 2020, 6:00 pmClosed
CWE
HQ CWE AF Bhisiana
Repair Replacement and Maintenance of DG Set installation along with allied works in Domestic area at AF Station Bhisiana
2020_MES_362701_1
CWE(BHI)/BHI-17/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AFS Bhisiana
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
GE AF Bhisiana
₹16,000
Yes
28 Aug 2020
21 Jul 2020
19 Aug 2020
21 Jul 2020
17 Aug 2020
4 Aug 2020
22 Jul 2020 - 29 Jul 2020
Amount
Supply and replacing set of fuel pre- filters and fine -filters as per sample and make for 160 KVA capacity of DG set. Each set shall be comprising complete set of pre/fine filters complete all as specified and as directed.
All as per Sr Item No 1.00 here-in-before but for 100 KVA.
All as per Sr Item No 1.00 here-in-before but for 82.5 KVA.
All as per Sr Item No 1.00 here-in-before but for 62.5 KVA.
All as per Sr Item No 1.00 here-in-before but for 40 KVA.
All as per Sr Item No 1.00 here-in-before but for 30 KVA.
All as per Sr Item No 1.00 here-in-before but for 25 KVA.
Supply and replacing Air filters as per sample and make for 160 KVA capacity of DG set. Each set shall be comprising complete set of air filters complete all as specified and as directed.
All as per Sr Item No 8.00 here-in-before but for 100 KVA.
All as per Sr Item No 8.00 here-in-before but for 82.5 KVA.
All as per Sr Item No 8.00 here-in-before but for 62.5 KVA.
All as per Sr Item No 8.00 here-in-before but for 40 KVA.
All as per Sr Item No 8.00 here-in-before but for 30 KVA.
All as per Sr Item No 8.00 here-in-before but for 25 KVA.
Supply and replacing lube oil super by pass filter suitable for 160 KVA complete all as specified and as directed.
Supply and replacing set of lube/ engine oil filters as per sample and make for 160 KVA capacity of DG sets. Each set shall be comprising complete set of complete all as specified and as directed.
All as per Sr Item No 16.00 here-in-before but for 100 KVA.
All as per Sr Item No 16.00 here-in-before but for 82.5 KVA.
All as per Sr Item No 16.00 here-in-before but for 62.5 KVA.
All as per Sr Item No 16.00 here-in-before but for 40 KVA.
All as per Sr Item No 16.00 here-in-before but for 30 KVA.
All as per Sr Item No 16.00 here-in-before but for 25 KVA.
Supply and fix in replacement Low oil pressure switch 12 V ,1.7kg / sq cm, complete all as specified and as directed.
Supply and fixing in replacement of battery lead of copper conductor PVC insulated multi strand size 4 AWG gauge, 1.25 Mtr long (two Nos) duly fixed with terminals and lugs, complete all as directed.
Supply and fix in replacement V- belt for fan A 56/A55/B47, complete all as specified and as directed.
Supply and fix in replacement stopping solenoid 24V for 160 KVA DG set, complete all as specified and as directed.
Supply and fix in replacement stopping solenoid 12 V for any type/any capacity of DG set, complete all as specified and as directed.
Supply and fix in replacement Benjo bolts complete including washers (02 washers for each bolt), complete all as specified and as directed.
Supply and fix in replacement fuel pipe, fuel filter to FIP wire braided, complete all as specified and as directed.
Supply and fix in replacement fuel pipe upto 15 mm size from fuel tank to the DG set & over flow return complete all as specified and as directed.
Material and labour for descaling and servicing the radiator of DG set 160/100 KVA internally and externally by using chemicals, including soldering the copper tubes and tankfor arresting leakage etc, complete all as specified and as directed.
Material and labour for descaling and servicing the radiator of DG set 82.5/62.5 KVA internally and externally by using chemicals, including soldering the copper tubes and tank for arresting leakage etc, complete all as specified and as directed.
Material and labour for descaling and servicing the radiator of DG set 40/30/25 KVA internally and externally by using chemicals, including soldering the copper tubes and tank for arresting leakage etc, complete all as specified and as directed.
Supply and fir in replace Water outlet and inlet hose pipe from radiator to Engine and back from Engine to radiator as per existing size, complete all as specified and as directed.
Supply and fix replace Lub oil pipe as per existing size/make, complete all as specified and as directed.
Supply and fix replace Anti vibration rubber pad for radiator, complete all as specified and as directed.
Supply and fix replace DC ameter 12 V of range (-) 30 to (+)30 A, complete all as specified and as directed.
Supply and fix replace Lub oil pressure guage 0 to 10 kg / sq cm, complete all as specified and as directed.
Material and labour for reconditioning of battery 12 volt 150 AH any make and any type opening up and taking out all dead battery cell plates, terminal post and mixture of acid using same container of battery and replacing of new solution, battery cell, plates, making terminals all as specified and directed.
Material and labour for reconditioning of battery 12 volt 90 AH any make and any type opening up and taking out all dead battery cell plates, terminal post and mixture of acid using same container of battery and replacing of new solution, battery cell, plates, making terminals all as specified and directed.
Repairing the self starter 24Volts after removing from the Gen set of any capacity and transporting to an authorised sevice centre and back, complete all as specified and as directed.
Repairing the self starter 12Volts after removing from the Gen set of any capacity and transporting to an authorised sevice centre and back, complete all as specified and as directed.
Supply and fix in repair Armature for any capacity of DG set, complete all as specified and as directed.
Supply and fix in repair in repair bendix of suitable size all as directed.
Supply and fix in repair in repair bearing /bushes complete all as specified and as directed.
Supply and fix replace Relay switch complete of suitable size complete all as specified and as directed.
Material and labour for Repairing the self Dynamo 12 Volts after removing from the Gen set of any capacity and transporting to an authorised sevice centre and back complete all as specified and as directed.
Supply and fix in repair Automatic Voltage regulator (AVR) of suitable size complete all as specified and as directed.
Supply and fixing in replacement A series electronic timers on/off delay function model A1D1 / AIDCS ,12 V DC, with time range 0.3 S to 30Min. Make EAPL or equivalent suitable for AMF panel complete all as specified and as directed.
Supply and fixing in replacement under/over voltage relay input voltage 110-220 V AC suitable for AMF panel complete all as specified and as directed.
Supply and fixing in replacement engine starting relay DC 12V/24V suitable for AMF panel complete all as specified and as directed.
Supply and fixing in replacement Genral purpose miniature relay, MSP type 3-5 Amp with LED indication 4Poles suitable for AMF panel complete all as specified and as directed.
Supply and fixing in replacement 8 pin PLC control relay, voltage range DC voltage 12 V to 230 V and AC voltage 12 V to 440V suitable for AMF panel complete all as specified and as directed.
Supply and fixing in replacement 8 pin relay Base Socket voltage range DC voltage 12 V to 230 V and AC voltage 12 V to 440V suitable for AMF panel complete all as specified and as directed.
Supply and fixing in replacement contact element NO-NC suitable for AMF panel complete all as specified and as directed.
Supply and fixing in replacement green colour Actuator Push button with complete set suitable for AMF panel complete all as specified and as directed.
Supply and fixing in replacement Red colour Actuator Push button with complete set suitable for AMF panel complete all as specified and as directed.
Supply and fixing in replacement HRC fuses 4 A to 20 A complete all as specified and as directed.
Supply and fixing in replacement indicator lamps DC filament type 10 W ,12 V complete all as specified and as directed.
Supply and fixing in replacement indicator lamps AC 230 V, LED type for the panel boards complete all as specified and as directed.
Supply and fixing in replacement Current Transformer as required for the Gen/ AMF panel complete all as specified and as directed.
Supply and fixing in replacement Ameter of range as required for the Gen/ AMF panel complete all as specified and as directed.
Supply and fixing in replacement Volt meter 0 to 600 V range suitable for the Gen/ AMF panel complete all as specified and as directed.
Supply and fixing in replacement frequency meter 45 to 60 Hz range suitable for theGen/ AMF panel complete all as specified and as directed.
Supply and fixing in replacement main contactor 250A, 4 pole suitable for AMF panel complete all as specified and as directed.
Supply and fixing in replacement main contactor 160A, 4 pole suitable for AMF panel complete all as specified and as directed.
Supply and fixing in replacement main contactor 130A, 4 pole suitable for AMF panel complete all as specified and as directed.
Supply and fixing in replacement main contactor 100A , 4 pole suitable for AMF panel complete all as specified and as directed.
Supply and fixing in replacement main contactor 63A , 3 pole suitable for AMF panel complete all as specified and as directed.
Supply and fixing in replacement 3 pole power contactor 55 A, type MNX 40 CAT No. CS94190 complete all as specified and as directed.
Supply and fixing in replacement auxiliary contactor of suitable size for AMF panel complete all as specified and as directed.
Supply and fixing in replacement On load change over switch 4 pole of capacity 160 amps, 415 Volts including thimbles, nuts bolts, washers of suitable size in sheet metal encloser complete MS angle grouted in wall for fixing change over switch Cat Pat No. ICAE0160.
Supply and fixing in replacement On load change over switch 4 pole of capacity 125 amps, 415 Volts including thimbles, nuts bolts, washers of suitable size in sheet metal encloser complete MS angle grouted in wall for fixing change over switch Cat Pat No.ICAE0125.
Supply and fixing in replacement On load change over switch 4 pole of capacity 63 amps, 415 Volts including thimbles, nuts bolts, washers of suitable size in sheet metal encloser complete MS angle grouted in wall for fixing change over switch Cat Pat No.INAE0063.
Supply and fixing in replacement On load change over switch 4 pole of capacity 200 amps, 415 Volts including thimbles, nuts bolts, washers of suitable size without enclouser, complete all as specified and as directed.
Supply and fixing in replacement On load change over switch 4 pole of capacity 160 amps, 415 Volts including thimbles, nuts bolts, washers of suitable size without enclouser, complete all as specified and as directed.
Supply and fixing in replacement On load change over switch 4 pole of capacity 125 amps, 415 Volts including thimbles, nuts bolts, washers of suitable size without enclouser, complete all as specified and as directed.
Material and labour for Drain the out lived engine oil, clean the oil sump and filling the engine oil as required, complete all as specified and as directed.
Supply and fixing in replacement MCCB 4 pole 200 A rating, breaking capacity Icu at 415V,36 KA with adjustable thermal setting with necessary fixing accessories, complete all as specified and as directed.
Supply and fixing in replacement MCCB 4 pole 160 A rating, breaking capacity Icu at 415V, 36 KA with adjustable thermal setting with necessary fixing accessories, complete all as specified and as directed.
Supply and fixing in replacement MCCB 4 pole 125 A rating, breaking capacity Icu at 415V, 36 KA with adjustable thermal with necessary fixing accessories, complete all as specified and as directed.
Supply and fixing in replacement MCCB 4 pole 63 A rating, breaking capacity Icu at 415V, 25 KA with adjustable thermal setting with necessary fixing accessories, complete all as specified and as directed.
Supply and fixing in replacement MCCB 4 pole 100 A rating, breaking capacity Icu at 415V, 25 KA with adjustable thermal setting with necessary fixing accessories, complete all as specified and as directed.
Supply and fixing in replacement MCB FP 63 Amps, 10 kA 'C' series with necessary fixing accessories, complete all as specified and as directed.
Supply and fixing in replacement MCB TPN 40 Amps, 10 kA 'C' series with necessary fixing accessories complete all as directed at site.
Supply and fixing in replacement MCB SP 6-32 Amps 10 kA 'B' series with necessary fixing accessories, complete all as specified and as directed.
Supply and fixing in replacement MCB SPN 6-32 Amps 10 kA 'C' series with necessary fixing accessories, complete all as specified and as directed.
Material and labour for GI earth strip 25 x 4mm for connecting earthings to test point, complete all as specified and as directed.
Material and labour for Earthing complete with galvanised iron earth plate electrode of size 600mm x 600mm x 6.3 mm thick buried directly under ground vertically to a depth not less than 2.25 meter below ground level with top edge of the plate at a depth not less than 1.5m below normal ground level connected to and including earth strip 32 x 6 mm with GI protection pipe 40 mm dia, light grade connected upto DB's/DG set by means of bolts, nuts, check nuts, and washers made out of copper all as shown on plate No. 5 of SSR Part-I upto 7.5m including necessary excavation earthwork, PCC 1:3:6 chamber, RCC 1:2:4 cover 50mm thick with 8mm TMT bars @ 140mm centre to centre, watering pipe medium grade 20mm bore, funnel, wire mesh, etc. and testing on completion all as specified and as directed.
Supply and fixing Battery Charger of capacity 24V suitable for any type AMF Panel, complete all as specified and as directed.
Supply and fixing Battery Charger of capacity 12V suitable for any type AMF Panel, complete all as specified and as directed.
Supplying & fixing in replacement GI pipe light grade 40 mm for earth strip protection test point to Dg Set complete with and including, fittings as requited all as specified.
Removing the cable from the existing trenches, cut the damaged/burning parts, crimping with suitable lugs and connecting/relaying the same all as directed for sizes 180/150/120 Sqmm 3.5 Core.
All as per Sr Item No 94.00 here-in-before but for 95/70/50 Sqmm 3.5 Core.
All as per Sr Item No 94.00 here-in-before but for 35/25 Sqmm 3.5 Core.
All as per Sr Item No 94.00 here-in-before but for 16 Sqmm 4 Core.
Supply and fix in repair Disc type coupling suitable for Kirloskar Engine/Cummins/ Mahindra.
Supply and fix in repair Glow Sign Board box type size 1.50x0.46x0.23 m having base height 0.75 M, which is show Dg capacity and location including painting black colour on metal parts excavation and using PCC 1:2:4 for foundation, complete all as specified and as directed.
Supply and laying control cable size 2.5 Sqmm 12 core, complete all as specified and as directed.
Supply and fixing LT service cable 10 Sqmm single core copper conductor with necessary thimbles suitable for AMF panel, complete all as specified and as directed.
Supply and filling distilled water for batteries of suitable grade complete all as specified and as directed.
Supply and fixing in replacement of ignition switch with key complete all as directed at site.
Material and labour for Repairing of alternator, engine mounted with replacement of rectifier, voltage regulator, diode plate and carbon brushes etc 24 V capacity complete all as specified and as directed.
Material and labour for Repairing of alternator, engine mounted with replacement of rectifier, voltage regulator, diode plate and carbon brushes etc 12 V capacity complete all as specified and as directed.
Supply and filling coolent, complete all as specified and as directed.
Removal of old painted surface of DG Set complete with fuel tank by scraping with emery paper and cleaning by thinner and finishing the surface smooth for new paiting of two coat of spray painting with synethetic enamal paint complete including writing of SM/MES No and colour code, complete all as specified and as directed.
Supply and fixing protocol (instruction board) for how to operate Gen set. Information, writing in Hindi and Punjabi on partical board 3.0 mm thick of size 1.00 Mtr x 1.25 Mtr with suitable aluminium frame including fix on wall, complete all as specified and as directed.
Supply and fixing first aid chart with pic and instruction 3.0mm thick of size 1.00 Mtr x 1.25 Mtr with suitable aluminium frame incuding fix on wall, complete all as specified and as directed.
Material and labour for complete AMF/LT panel rewiring by using 2.5 sqmm copper conductor of capacity DG Set of any Make/any type, complete all as specified and as directed.
Supply,laying,jointing and testing XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade, cross sectional area 25 sqmm 4 core, complete all as specified and as directed.
Supply,laying,jointing and testing XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade, cross sectional area 35 sqmm 31/2 core, complete all as specified and as directed.
Supply,laying,jointing and testing XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade, cross sectional area 50 sqmm 31/2 core, complete all as specified and as directed.
Supply,laying,jointing and testing XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade, cross sectional area 70 sqmm 31/2 core, complete all as specified and as directed.
Supply,laying,jointing and testing XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade, cross sectional area 95 sqmm 31/2 core, complete all as specified and as directed.
Excavation in trenches not exc 1.5 m wide and not exceeding 1.5m depth for foundation, laying of cables etc and getting out in soft/loose soil, complete all as specified and as directed.
Returning, filling including spreading, leveling watering and well ramming in layers not exceeding 25 cm, complete all as specified and as directed.
Removing excavated material (soil) n.exc 50m and depositing where directed at a level not exceeding 1.5 mtr above the starting point, complete all as specified and as directed.
Material and labour for providing dry river sand as in sand cushioning to under ground cable including punning down of sand in layers as specified and as directed
Material and labour for brick protection cover of UG cable by old size bricks common burnt clay building bricks sub class `B’ laid dry and flat abutting each other with width equal to length of brick and gap between adjacent brick not exceeding 10mm, complete all as specified and directed.
Material and labour cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate for foundation of DG set & LT Panel etc, complete all as specified and directed
Material and labour cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate for fixing of LT Panel (PCC) including necessary form work and plastering etc, ccomplete all as specified and as directed.
Supply and fix complete DG set controller system for any type/any capacity DG set as per sample or existing Make, complete all as specified and as directed.
Supply and fix in replacement of Stainless steel Canopy lock with Key for DG set any make any type, complete all as specified and as directed.
Supply and fix in replacement of generator door hinges metal type with nut bolts or screws for DG set any make any type, complete all as specified and as directed.
Supply and fix in replacement of fuel tank cap for any type/any capacity DG set as per sample or existing Make which, complete all as specified and as directed.
Supply and fix in replacement of radiator cap any type/any capacity DG set as per sample or existing Make, complete all as specified and as directed.
Supply and fix with replacement of B-12 Governor Rotary Actuator, engine mounted having control capability for both rotary and inline type mechanical diesel injection pumps, supports both fuel stop lever control as well as throttle lever control for any capacity/Any Make DG Set, complete all as specified and as directed.
Supply and Fix with replacement of generator rubber oil seal any size for any type/any capacity diesel engine, complete all as specified and as directed.
Supply and Fix with replacement of cylinder head gaske any size for any type/any capacity diesel engine, complete all as specified and as directed.
Material and labour for repairing of Generator fuel feed pump with necessary washers and filters for any type/any capacity of DG set, complete all as specified and as directed.
Taking down complete fuel tank of DG set capacity 62.5/75/100/125/160/200/437.5 KVA and cleaning of fuel tank inner and outer side,welding if any leakage than refix same place, complete all as specified and as directed.
Supply and fix with replacement Generator Fuel tank gauge with float valve, nut, bolts and gaskets including refix its setting AMFpanel Controoler System for any capacity/Any Make DG Set, complete all as specified and as directed.
NOTE : (1) Contractor has to attend the breakdown at any time and place of Air force Stn Bhisiana during the contract period. (2) The labour charge for attending any complaints any time for DG set and AMF panel shall be deemed to be included in quoted rates to contractor no extra charge shall be paid by department.
M/s Vee Kay Associates
M/s SUPERTECH ENGINEERS
Aman Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .