| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.6 CrAccepted-AOC 5 KEDAR APARTMENTS 484 60 PARVATI MITRAMANDAL COLONY PARATI PUNE 411 009 | PUNE | PUNE | MAHARASHTRA | 411009 | ₹1.6 Cr | L1 | Accepted-AOC REASONABLE LOWEST BIDDER |
| 2 | L2₹1.7 Cr+₹8.3 L (5.26%)Rejected-Finance | ₹1.7 Cr+₹8.3 L (5.26%) | L2 | Rejected-Finance NOT BEING LOWEST BIDDER |
| 3 | L3₹1.7 Cr+₹11.4 L (7.20%)Rejected-Finance | ₹1.7 Cr+₹11.4 L (7.20%) | L3 | Rejected-Finance NOT BEING LOWEST BIDDER |
| 4 | Rejected-Technical FLAT NO 10 S NO 98 PLAT NO 78 SAI SAYAJI PARK A RIGHT BHUSARI COLONY KOTHRUD PUNE 411 038 | PUNE | MAHARASHTRA | 411038 | - | - | Rejected-Technical Since adverse remarks of CESC under Part II of WLR for QE Mar 2022 |
Tender Value
₹1.7 Cr
EMD Value
₹2.4 L
Closing Date
7 Oct 2022, 5:00 pmClosed
Chief Engineer RND Secunderabad
Chief EngineerRND OPP JBS picket Secunderabad
ADDITION / ALTERATION TO BUILDING No. 119 (CEPP-01) AT HEMRL, PASHAN PUNE
2022_MES_541780_2
81367
Open Tender
Civil Works
Item Rate
270 days
Pashan Pune
Class B category ai
7 documents required · 7 mandatory
₹1,000
Yes
GE I RND PASHAN PUNE
₹2.4 L
Yes
1 Dec 2022
8 Sept 2022
14 Oct 2022
8 Sept 2022
7 Oct 2022
23 Sept 2022
Amount
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed.
Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), removing off the premises complete all as specified and directed.
Taking down chowkhats & frames with shutters (without taking off shutters from the frames) n exc 1.50 Sqm each complete all as specified and directed.
Taking down chowkhats & frames with shutters (without taking off shutters from the frames) exc 1.5 Sq. m but n exc 4 Sq. m each complete all as specified and directed.
Dismantling structural steel work including doors, gates but excluding framed truss etc, complete all as specified and directed.
Demolition of existing padding concrete of any description and in any position not otherwise specifically provided for / lime concrete / brick coba / APP membrane in any layer etc for roof complete and removing rubbish out of MoD land complete without making any damage to existing RCC slab complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for, complete all as specified and directed.
M&L for 25 mm thick PCC (1:2:4) type B1 (using 20mm graded aggregate) as base for laying floor finishes complete all as specified and directed.
M&L for 15 mm thick screed bed in CM 1:4 or bedding layer for laying floor finishes complete all as specified and directed.
M&L for backing coat 10mm thick cement plaster in CM 1:3 on brick / concrete surfaces specified and directed by the Engineer-in-Charge.
M&L for acid resistance tile conforming to IS-4457: 2007, not less than 15mm thick of size not exc. 36 Sqm viterous ceramic unglazed set jointed and pointed in chemical resistant mortar, resin type as in skirting / dado complete all as specified and directed.
M&L for coloured dark shade Non Skid ceramic tiles 7 to 8mm thick (square / rectangular) area of each tile exceeding 0.18 but not exceeding 0.38 Sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
M&L for coloured dark shade non skid ceramic tiles 7 to 8mm thick (square / rectangular) area of each tile exceeding 0.11 but not exceeding 0.18Sqm and shall be of premium quality (B-IIA Grade) confirming to IS-13712, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
M&L for glazed coloured (including designer tiles as approved by GE) ceramic tiles in vertical surface, of size 300 x 450 x 7 to 8mm thick set and joined in neat cement slurry and pointed in cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
M&L for acid resistant tile not less than 15mm thick viterous ceramic, unglazed, set jointed and pointed in chemical resistant mortar, resin type as in skirting / dado over and including 10mm thick back coat in CM skirting / wall over and 1:3 complete all as specified and directed.
M&L for double charged vitrified tiles 8 to 9mm thick (square / rectangular) in skirting / dado area of each tile exceeding 0.36 sqm but n exc 0.42 Sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
M&L for double charged vitrified tiles 8mm to 9mm thick (square / rectangular) area of each tile exceeding 0.36 sqm but n exc 0.42 Sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
Granite (of any type) tiles 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing over and including 15mm thick screed bed in cement mortar 1:4 complete all as specified and directed.
S&F, butt hinges 100mm size, bright finish stainless steel with galvanised mild steel hinge pincomplete all as specified and directed.
M&L for 35 mm flush door shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides face is covered with decorative face veneers with teak wood lipping / frame to match complete all as specified and directed.
S&F, 150 mm long aluminium barrel tower bolt, with barrel of extruded section and rolled or cast bolts and fixed complete all as specified and directed.
S&F, floor door stopper 150 mm of aluminium alloy body and tongue, anodised, with hard drawn steel spring fixed in floor complete all as specified and directed.
M&L for door closer hydraulically regulated, designation No. 2, universal type, suitable for door shutters of 701 to 850 mm in width and of weight between 36 to 60kg and fixed complete all as specified and directed.
M&L for rim latch 150 mm with two levers, of brass body, polished bright, stove enamelled finish; with brass knob or lever handle and fixed door lock with locking arrangement with keys made up with bright finish CP coating / stainless steel complete all as specified and directed.
Aluminium alloy, anodised, sliding door bolt 300mm with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified and directed.
S&F, 150mm aluminium handles, extruded type, anodised complete all as specified and directed.
S&F, 105 x 60mm pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc., complete as specified, supplied and fixed.
M&L for PCC type B0 1:2:4 (12.5 mm graded aggregate) as in bed plates complete all as specified and directed.
20mm thick marbles (Baroda green) as in slab machine cut in window cills, skirting risers, treads of steps including moulding edges laid over and including cement screed bed 15 mm thick and jointed with matching cement slurry including cutting and polishing complete all as specified and directed.
S&F, side hung steel windows glazed shutter as per IS 1038 using rolled steel section as per IS 7452 including hinges, hold fast, flat latches for locking inclusive of required fittings and fixtures and provision of peg stay inclusive of one coat of red oxide zinc chromate primer complete all as specified and directed. Note: Iron safety grills, glass panes & painting shall be measured and paid separately under respective items of BOQ.
S&F, powder coated aluminium section for partition, frames for doors and windows with one or more rebates including joining cleat, glazing clips, rubber packing, powder coated aluminium snap beading, screws for fixing etc, including powder coating minimum thickness of powder coating shall be 50 micron complete all as specified and directed.
S&F, powder coated aluminium door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc, complete all as specified and directed. Size of aluminium section (Jindal CAT K 2005) shall be as under: - (a) Shuttern vertical - Section Nos. 19569 & 19502. (b) Shutter Top - Section No. 19571. (c) Shuttern Middle - Section No. 20014. (d) Shutter bottom - Section No. 19352.
S&F, aluminium sliding windows three track with two glass shutters using 5.5 mm thick tinted glass (Modi Guard) and on shutter with stainless steel wire gauge of 0.31 mm dia, 1.61 mm average aperture using powder coated aluminium sections including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc complete all as specified and directed. Note: 5.5 mm thick tinted glass and stainless wire cloth shall be measured and paid separately. Size of aluminum sections are as under: - (i) Three track top & vertical - Jindal main - 2010 Section No. 20621. (ii) Three track bottom - Jindal main - 2010 Section No. 20620. (iii) Shutter vertical section - Jindal main - 2010 Section No. 20606. (iv) Shutter top & bottom - Jindal main - 2010 Section No. 20604 (v) Shutter vertical middle (interlock) - Jindal main - 2010 Section No. 20605.
S&F, framed work such as grills, gratings etc, with ends of bars shouldered and / or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed.
M&L for prelaminatd particle board 12mm thick, exterior grade, type-1, as per IS-12823 prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to aluminium frame work complete all as specified and directed.
S&F, rough cast wired figured glass, 6.4mm thick and glazing with oil putty in square exc 0.75 but not exc 1.0 Sq m in each pane for partition complete all as specified and directed.
S&F, 6mm thick reflective toughened glass, curtain wall glazing frame of size 63mm x 57mm, 16 guage, aluminium Jindal section and curtain wall clips 57mm curtain base 57mm with powder coating any colour, 25mm x 38mm 'L' angle, EPDM rubber 10mm x 100mm fastener, 75mm x 75mm x 6mm thick bracket, 10mm x 100mm nut bolts and openable window complete including all necessary bracket, fittings for the fixing on wall as per requirement including necessary scaffolding all as specified and directed.
M&L in replacement double action floor door spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation body, main box with stainless steel cover, governing pivot made of brass, other part made of mild steel heavy duty for aluminium doors complete all as specified and directed by Engineer-in-Charge.
S&F, steel ventilators with top hung glazed shutter as per IS 1038 using rolled steel section as per IS 7452 including hinges, hold fast, flat latches for locking and provision of peg stay inclusive of one coat of red oxide zinc chromate primer complete all as specified and directed. Note: Iron safety grills, glass panes & painting shall be measured and paid separately under respective items of BOQ.
Taking down gear operated rolling steel shutter complete all as specified and directed.
Taking down rolling shutter complete all as specified and directed.
S&F steel rolling shutters of thickness of laths 1.25 mm, with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer, erected in position as indicated complete push pull or manual type.
All as per Sl item No. 43 above but, gear operated type with bevel gear box and crank handle.
Preparation of new steel surfaces of any description, not otherwise described over 10cm width or girth and applying two coats of aluminium painting over a coat of primer complete all as specified and directed.
Taking down collapsible gate area of gate n exc 10 sqm complete all as specified and directed.
S&F, collapsible steel gates top hung consisting of channel pickets, pivoted flat bars top and bottom runners brass handles etc as specified erected in position and securing runners with holdfasts and brackets complete all as specified and directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation etc.) or insulation boards / slabs / blankets, any thickness, including cover fillets complete all as specified and directed.
Anodised aluminium snap grid frame work for false ceiling all as specified hangers 6mm dia GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 x 3mm size 60mm long and expansion hold fasteners 12.5mm dia, 40mm long complete all as specified perforated particle board / tiles 16mm for insulation and acoustic purposes, 60 x 60 cm in size, fixed frame work or with staples on snap grid complete all as specified and directed.
M&L for PCC 1:2:4, type B0, (using 12.5mm graded aggregates) average thickness 40mm as in levelling course / padding / coping on roof / sunken slab or chajjas etc to level the undulations of roof or to maintain the slope of roof etc complete all as specified and directed.
Rendering 10mm thick in CM (1:4) on green concrete surfaces of roof slab, projections and parapets mixed with WPC complete all as specified and directed. Note: Water proofing compound shall be measured and paid separately.
Supply only integral liquid WPC of approved make Dr Fixit, Fosroc complete all as specified and directed.
PCC 1:2:4, type B0 (using 12.5mm graded stone aggregate) as in benching, copings, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating as directed including necessary formwork, complete all as specified and directed.
Brushing neat cement slurry with wpc 3.0kg of cement per sq. metre complete all as specified and directed.
S&F, 3mm thick APP pre-fabricated membrane with non woven polyester matt central core of 160 gsm (min) impregnated and coated on both side layer of APP modified bitumen and finished with micro-perforated heat fusible polyuthene film on both surfaces over 0.3 ltrs/Sqm bituminous primer confirming to IS-3384. The weight of APP membrane shall not less than3.0 kg/Sqm and laid over primed surface by using torch and aply uniform preserve with roller. The overlap of membrane shall be 100mm on sides and 150mm on end laps. Applying a coat of hot blown bitumen 85/25 grade @1.2Kg/Sqm over the membrane and finally applying two coats of aluminium paint @ 0.10 ltrs/Sqm as directed by Engineer-in-Charge. Make: Torch shield, Asian paints smart care APP membrane, IWL, SIkka, Forsroc Note: (i) The work should be executed through authorised applicator only. Approval of which shall be taken from GE before commencement of work. (ii) The contractor has to furnish guarantee for 10 years for APP membrane.
M&L for brickwork with fly ash bricks, straight or curved on plan to any radius in half brick thick walls built in CM (1:4) complete all as specified and directed.
M&L for rendering 10mm thick cement plaster in CM 1:4 on other than fair faces of brick / concrete surfaces finished even and smooth with specified and directed by the Engineer-in-Charge.
Rendering 15mm thick in CM 1:4 on brick / concrete sufaces finished even & smooth using extra cement mixed with liquid water proofing compound as per mfg instruction complete all as specified and directed.
M&L for applying Epoxy Resin coating polymer modified cementeous coating like Brush Bond of Fosroc or eqivallent complete all as specified and directed.
S&F, stainless steel railing in 304 grade material for staircase railing of height 0.95m with top rail pipe 75mm dia 16 gauge, verticle pipe 50mm dia 16 gauge @ n.exc 2.00m centre to centre and turning and corners and three longitudinal parallel pipe of size 20mm dia 16 gauge including connected socket, base coupling, brackets, tee, cross bend, fixing side of steps with necessary fasteners complete mat finish including dismantling of old existing railing complete all as specified and directed.
Scraping loosened / cracked concrete of RCC structure at any location by chiselling etc including removal of debris away from n.exc 500 mtr site all as specified and directed.
M&L for applying one coat epoxy based concrete bonding agent over the existing concrete surface to bond old surfaces to receive cement mortar with / guniting including preparation of old concrete surface by wire brushing making surface dirt / dust free complete all as specified and directed.
S&F, hard down steel wire fabric not exceeding 4 kg/sqm cut to lengths, bent to shape mild steel wire, (annealed) not less than 0.9mm dia as in reinforcement as directed by Engineer-in-Charge.
M&L for mild steel deformed TMT bars 10mm dia and over cut to length cranking bending spirally or hopping ends MS wire annealed not less than 0.9mm dia complete all as specified and directed.
All as per Sl item No. 64 above but, 8mm dia and above bars as stirrups in columns.
M&L for pressure guniting 25mm thick lath over existing RCC structure with CM (1:3) incorporating with approved acryic polymer agent and 5mm thick plaster CM (1:4) for finished the gunited surfaces even and fair without using extra cement including scaffolding any height from base complete all as specified and directed. Note: Acyrlic polymer shall be measured and paid seperately under relevant items of this Schedule.
Supply only, Arcylic polymer agent of approved make for pressure guniting complete all as specified and directed.
M&L for preparation of old plastered surfaces of walls and applying two coats of distemper oil emulsion over a coat of alkali resistant primer complete all as specified and directed.
M&L for preparation of old plastered surfaces of ceiling and applying two coats of distemper oil emulsion over a coat of alkali resistant primer on ceiling complete all as specified and directed.
Taking down cement plaster on brick / concrete / stone surface including raking out joints, hacking for key scrubbing down with water etc, complete all as specified and directed.
Rendering 5 mm thick in CM 1:3 on concrete surfaces as in ceiling finished even & smooth without using extra cement including necessary scaffolding at any height complete all as specified and directed.
M&L for 15mm thick rendering on brick work / block masonry in CM (1:4) in two layers 10 mm thick in first layers and 5 mm thick in second layers with liquid water proofing compound finished even and smooth without using extra cement including necessary scaffolding at any height complete all as specified and directed. Note: Liquid water proofing compound shall be measured and paid separately.
M&L for 15mm thick rendering on brick work / block masonry in CM (1:6) finished even and smooth without using extra cement complete all as specified and directed.
M&L for preparation of new plastered surfaces of walls including 3mm wall care putty and applying two coats of distemper oil emulsion over a coat of alkali resistant primer complete all as specified and directed.
M&L for preparation of new plastered surfaces of ceilings and applying three coats of white wash complete all as specified and directed.
M&L for applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre / 10 Sqm over and including priming coat of exterior primer applied @ 0.90 litre / 10 Sqm over new surfaces including necessary scaffolding at any height complete all as specified and directed.
M&L for complete removal of existing treatment by scrapping down with wire brushes; washing & drying up filling with exterior grade wall care putty where undulated on wall and applying two coat of exterior acrylic emulsion over a coat of acrylic primer after preparation of surfaces at any height including necessary scafolding etc complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of old steel surfaces any description, not otherwise described, over 10 cm width / girth and applying two coats of synthetic enamel paint complete all as specified and directed.
M&L for preparation of new steel surfaces any description, not otherwise described, over 10 cm width / girth and applying two coats of synthetic enamel paint complete all as specified and directed.
Demolition of cement concrete of any description and in any position not otherwise specifically provided for (unreinforced) complete all as specified and directed.
Demolition of brickwork of stone / boulder masonry, build in lime mortar including all quoins, arches, pillars etc, but excluding ashlars facings, dressed stonework and precast concrete articles complete all as specified and directed.
M&L for PCC 1:5:10 type E2 (40 mm graded aggregate) filling in sunken portion complete all as specified and directed.
Providing precast cement concrete solid building blocks or slabs 10cm thick (with plain or interlocking joints as directed) setting in mortar, complete in walls set in cement mortar 1:6, type C1, 1:3:6 (20 mm graded aggregate) complete all as specified and directed.
M&L for rendering / backing coat 10mm thick in CM (1:3) on fair faces of brick work or concrete surfaces complete all as specified and directed.
M&L for glazed ceramic tiles coloured in vertical surface 300 x 600mm x 8-10mm thick premium quality, set and jointed in neat cement slurry and pointed in white or coloured cement to match over rendering 10mm thick with CM (1:3) on fair faces of brick work or concrete surfaces all as specified and directed by Engineer-in-Charge.
Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and directed.
Taking up or down steel tubing and connections 15mm dia bore, including cleaning for re-fixing or removal to store complete all as specified and directed.
Taking up or down steel tubing and connections 20mm dia bore, including cleaning for re-fixing or removal to store 2 complete all as specified and directed.
Refixing old steel tubing and connections 15 mm dia bore in new or old position (walls, ceiling, floors etc.) complete all as specified and directed.
Refixing old steel tubing and connections 20 mm dia bore in new or old position (walls, ceiling, floors etc.) complete all as specified and directed.
S&F, 15mm dia bore, GI tubing medium grade, galvanised with all fittings and fixed complete to walls and ceilings or laid in floor etc, complete all as specified and directed.
S&F, 20mm dia bore, GI tubing medium grade, galvanised with all fittings and fixed complete to walls and ceilings or laid in floor etc, complete all as specified and directed.
M&L for cutting chases, pinning in brick masonary making good to facings where required and pointing in CM 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels etc; and cutting chases for concealed water tubing or concealed conduit wiring, etc, and making good, cutting not exc 10cm girth complete all as specified and directed.
S&F, stop cock 15mm dia, fancy type, chromium plated cast copper alloy screwed pressure, with crutch of butterfly handle, screwed both ends for iron pipe for unions and fixed complete all as specified and directed.
S&F in repairs, self-closing taps, 15 mm dia cast copper alloy, chromium plated, screwed for iron pipe and fixed complete all as specified and directed.
S&F, urinal spreader of PTMT any colour for fixing with 15mm dia pipe (minimum weight 60gms) complete all as specified and directed.
S&F, PVC connections 15mm size with PTMT nuts of length 450 mm complete all as specified and directed.
S&F, 15mm bore, CP fancy type bib taps, cast copper ally with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
S&F in repairs, 15mm pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe complete all as specified and directed.
S&F in repairs, brass chromium plated shower rose 125mm size complete all as specified and directed.
S&F in repairs, vitreous China wash basin flat back type white, size 550 x 400mm,15mm bore CP fancy type pillar tap,CP brass coupling, PVC waste pipe 32mm dia, PVC connection pipe 15mm dia and necessary fitting etc all as approved and directed by Engineer-in-Charge.
Liquid soap container of PTMT fixed with and including chromium plated brass screws and wooden / plastic leats (Minimum weight 105gms) complete all as specified and directed.
S&F, towel rail 600mm long, 20mm dia brass chromium plated fixed with and including chromium plated brass screws and wooden / plastic cleats (Minimum weight 190 gms) complete all as specified and directed.
S&F in repairs, vitreous China ware water closet (Orissa pattern) long pan of size 580mm x 440mm white with integral foot rests with ‘P’ or ‘S’ trap front or back inlet complete including provision of cement concrete bedding complete fixed in repair and all specified and directed by Engineer-in-Charge.
S&F, vitreous China wash down water closet pan (pedestal pattern), white including fixing bolts (excluding flushing cistern and flush pipe) add fixed in repairs including pan seat cover complete all as specified and directed.
S&F, PVC flushing cistern 10 litres capacity syphonic action type, low level, white with inlet, ball valve, float, handle and flush pipe etc, 'P' or 'S' trap complete all as specified and directed.
S&F in repairs, vitreous china urinals, full stall type complete including CP self closing 15mm bore tap (Push Cock), 32mm CP coupling, 32mm waste pipe fixing brackets plugs complete all as specified and directed.
S&F, Push cock, CP fancy type 15mm bore complete all as specified and directed.
M&L for high density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2 bore of pipe 40 mm laid in trenches complete all as specified and directed.
Taking down cast iron pipe any type in any position spigot and socket ends and lead joints including burning out joints and recovering lead complete all as specified and directed.
S&F, PVC (SWR) pipes double socketed in any length with rubber ring joints fixed to walls 110mm bore complete all as specified and directed.
S&F, PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls 75 mm bore complete all as specified and directed.
S&F, PVC (SWR) bends any radius, shoe, socket etc 110 mm bore including clamp & oval access door complete all as specified and directed.
S&F, PVC (SWR) bends any radius, shoe, socket etc 75mm bore including clamp & oval access door complete all as specified and directed.
S&F, PVC (SWR) branch piece, double (double Y), equal or unequal 110mm bore complete all as specified and directed.
S&F, PVC (SWR) branch piece, double (double Y), equal or unequal 75mm bore complete all as specified and directed.
S&F, PVC (SWR) branch piece, single (single Y) equal or unequal 110mm bore complete all as specified and directed.
S&F, PVC (SWR) branch piece, single (single Y) equal or unequal 75mm bore complete all as specified and directed.
S&F in repairs, CI nahani traps, 75 mm dia with SS grating including jointing to waste pipe and fixed in cement concrete 1:2:4 type B1 (using 20 mm graded stone aggregates) complete all as specified and directed.
S&F in repairs, cast iron floor trap, 100 mm dia with SS grating including jointing to waste pipe and fixed in cement concrete 1:2:4 type B1 (using 20 mm graded stone aggregates) complete all as specified and directed.
S&F in repairs, rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) double layered and ISI marked hoisted and fixed in position all as specified in SSR Part-I including ball brass valve, high pressure float and fly nut complete, screwed for iron pipe or brass ferrule and fixed of 20mm dia of capacity 1000 Ltr with 20dia nipple suitable for HDPE water tank (minimum weight 20mm-45gms) complete fixed to pipe etc all as specified and directed by Engineer-in-Charge.
S&F, gun metal, globe or gate valves, 20mm dia bore with iron wheel head, screwed both end for iron pipe and fixed complete all as specified and directed.
S&F, factory made solid PVC door frame of size 50mm x 47mm made out of 5 mm colour PVC sheet single side prelam PVC Sheet used instead of Plain colour PVC sheet & edges will be painted to match with prelam sheet reinforced with MS square tube complete all as specified and directed.
S&F, factory made solid PVC moulded door shutters 28 to 30 mm thick (tile), with 2, 4 or 6 raised panel design with 5mm thick Moulded PVC Sheet on the front face & 5mm Prelam / plan colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing complete all as specified and directed.
Demolition & breaking up drain pipes (salt glazed ware / AC / RCC) set in CM of pipe 150 mm dia complete all as specified and directed.
M&L for PCC (1:3:6) type C2 (using 40 mm graded aggregate) as in bed to drain pipe including packing under & haunching against the sides of pipes of 150 mm dia after they are laid tested complete all as specified and directed. Note: Thickness of bed below pipe shall be 10cm and width shall be outer dia of pipe plus 30cm.
M&L for reinforced concrete pipes, class NP-2, laid and jointed complete with collars of dia 150 mm complete all as specified and directed.
Excavation in trenches; not exc 1.50 m depth & n. exc1.50m wide for foundation & getting out in any type of soil complete all as specified and directed.
Demolition of reinforced cement concrete of any descreption and in any position above or below ground level complete all as specified and directed.
M&L for precast cement concrete type B1, 1:2:4 (using 20 mm graded aggregate) as in landings, cover slabs for man holes etc and similar articles with plain faces set in cement morter (1:4) complete all as specified and directed.
M&L for mild steel deformed TMT bars 6 to 8mm dia and over cut to length bent to shape required including cranking bending spirally etc and binding with MS wire (annealed) not less than 0.9 mm dia or securing clips complete all as specified and directed.
M&L for rendering 10mm thick cement plaster in CM 1:4 on other than fair faces of brick / concrete surfaces finished even and smooth with using liquid WPC @ 3% by weight of cement in MH all as specified and directed by the Engineer-in-Charge. Note: Integral liquid water proofing compound shall be measured and paid separately.
Supply only liquid water proofing compound complete all as specified and directed.
Demolition of brick work or stone / boulder masonry built in cement morter or cement lime mortar including all quoins, pillars, arches etc, and clearing off the premises complete all as specified and directed.
M&L for pre-cast cement concrete block masonry type C1, 1:3:6 (20mm graded aggregate) with solid blocks exc. 10cm in width and setting in cement mortar 1:6 complete all as specified and directed.
Removing excavated material to a distance upto 250m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed.
Returning filling in including spreading, levelling, watering & well ramming in layers not exe 25cm complete all as specified and directed.
M&L for PCC type C-2, 1:3:6 (using 40mm graded stone aggregate) as in plinth protection, 75 mm thick, including bitumenous seal finished the surface fair and even complete all as specified and directed.
M&L for reinforced cement concrete nominal mix type B0 1:2:4 (using 12.5mm graded aggregate) in beams, canlilevers, bressummers, lintels over 1.5m span complete all as specified and directed.
M&L for formwork to flat rough finished sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs etc, also splays between floors and beams etc, complete all as specified and directed.
M&L for complete removal of existing treatment of surfaces of any description wood, steel, iron, concrete, brick, stone etc, including preparation and applying of two coats of fire resistance paint over and including a coat of primer complete all as specified and directed.
FENCING & GATES Excavation in trenches n. exc 1.5m wide and n.exc 1.5m wide and n.exc 1.5m in depth and getting out in hard / dense soil complete all as specified and directed.
M&L for PCC 1:4:8, type D2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and directed.
Fixing only, chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire complete all as specified and directed.
Supply only, chain link MS galvanised fencing, any size or type complete all as specified and directed.
Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut exc 5cm & n exc 10cm long complete all as specified and directed.
M&L for preparation of new steel surfaces any description not otherwise described, over 10 cm width / girth and applying two coats of synthetic enamel paint over a coat of red oxide complete all as specified and directed.
Rendering 15mm thick in CM 1:4 on brick / concrete sufaces finished even & smooth using extra cement specified and directed by the Engineer-in-Charge.
M&L for preparation of new plastered surfeces of wall and applying two coats of cement based paint over a coat of primer complete all as specified and directed.
INTERNAL ELECTRIFICATION Taking down Existing copper / aluminium point wiring including taking down of fixture such as light / fan / plug / bell / power point and all electrical fittings any type including making good the disturbed surfaces of wall / ceiling etc removing materials under Schedule of Credit complete all as specified and directed.
Taking down existing copper / aluminium flame proof point wiring on stove enemelled steel / ERW conduit along with fittings / fixture such as light / fan / plug / bell / power point and all electrical fittings any type including making good the disturbed surfaces of wall / ceiling etc removing materials to store for keeping in safe custody complete all as specified and directed.
Taking down existing unserviceable DBs with MCBs any type and any capacity including making good to the distrubed surface of wall complate all as specified and directed.
Dismantling the existing sub main wiring / earth wire 2/4/6 runs of cable of any size / any type along except stove enemelled steel / ERW conduit alongwith fixture and fitting including making good to the distrubed surface of wall complete all as specified and directed.
M&L for point wiring (concealed) in existing conduit pipe, with 1.5 Sqmm PVC insulated unsheathed FRLS stranded copper conductor cable, single core, 1100 volts grade as per IS colour code, with 3 mm thick plastic laminated sheet cover with brass screw, cup washer and including PVC insulated & unsheathed stranded copper conductor of 1.5 Sq mm as continuous earth wire complete all as specified for one light point controlled by one switch one way.
All as per Sl item No. 155 above, but for one exhaust / fan point controlled by one switch.
All as per Sl item No. 155 above, but for one 5 Amps socket outlet point on same board controlled by one switch.
All as per Sl item No. 155 above, but for one 5 Amps socket outlet point on independent board controlled by one switch.
All as per Sl item No. 155 above but, power point wiring with 2.5 Sqmm single core PVC insulated unsheathed cable with stranded copper conductor for one switch socket outlet, 5/15 Amps multi purpose on independent board including PVC unsheathed copper conductor of 2.5 Sqmm as earth wire.
M&L for point wiring (concealed) with 1.5 Sqmm size single core PVC insulated sheathed multistranded FRLS copper conductor 1100 volts grade with & including suitable size of PVC conduit with conduit accessories ISI marked including 1.5 Sqmm single core PVC insulated FRLS copper wire green in colour for earth continuity conductor connected to common earth dolly with provision of connector for connection of ceiling fan / exhaust fan / bracket fan and T/L fittings for one light point / fan point controlled by one way switch.
All as per Sl item No. 160 above, but for one bell point controlled by one way switch.
All as per Sl item No. 160 above, but for one 5 Amps socket outlet point on same board controlled by one switch.
All as per Sl item No. 160 above, but for one 5 Amps socket outlet point on independent board controlled by one switch.
All as per Sl item No. 160 above but, power point wiring with 4.0 Sqmm single core PVC insulated unsheathed cable with stranded copper conductor for one switch socket outlet, 5/15 Amps multi purpose on independent board including PVC unsheathed copper conductor of 4.0 sqmm as earth wire all as directed by Engineer-in-Charge.
M&L for flame proof point wiring with 1.5 Sqmm, PVC insulated and unsheathed FRLS cable of copper conductor, multistranded, single core 1100 volts grade in stove enameled / ERW steel conduit alongwith flame proof accessories on surface of walls, ceiling etc; for flame proof application and connecting up of the fitting, including 1.5 Sqmm dia PVC insulated copper conductor to PVC insulated unsheathed FRLS cable green in colour for earth continuity and connected to earth dolly complete for one flame proof light point point controlled by one; single pole switch / rotary switch.
All as per Sl item No. 165 above, but for one exhaust / fan point controlled by one switch.
All as per Sl item No. 165 above but, power point wiring with 4.0 Sqmm single core PVC insulated unsheathed cable with stranded copper conductor for flame proof switch socket outlet, 16 Amps multi purpose on independent board including PVC unsheathed copper conductor of 4.0 Sqmm as earth wire all as directed by Engineer-in-Charge.
S&F, switch piano, flush type single pole, one way, 5 Amps, 240 volts complete all as specified and directed.
S&F, switch socket combination 2 in 1, 3 pin, 5 A, flush type complete all as specified and directed.
S&F, switch socket combination 5 in 1, 6 pin, 5A/16A, flush type universal complete all as specified and directed.
S&F, ceiling rose surface bakelite, 65x50mm three terminals 230 Volts, AC Single phase complete all as specified and directed.
S&F, stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as required complete all as specified and directed.
S&F, buzzer, ding dong AC, 230 volts, single pole complete all as specified and directed.
Sub main wiring with 2 runs of 4 Sqmm single core, multistranded PVC insulated unsheathed cable 1100 volts grade with copper conductor, drawn through and including concealed PVC conduit pipe with one run of 1 x 4.0 Sqmm PVC insulated unsheathed copper conductor cable as earth continuity conductor and connecting to common earth dully all as specified and directed by Engineer-in-Charge. Note: 2 runs of 4 Sqmm copper wire, one run of 4 Sqmm copper wire and one run of PVC conduit shall be measured as one unit.
Sub main wiring with 4 runs of 6 Sqmm single core, multistranded PVC insulated unsheathed cable 1100 volts grade with copper conductor, drawn through and including concealed PVC conduit pipe with one run of 1 x 6.0 Sqmm PVC insulated unsheathed copper conductor cable as earth continuity conductor and connecting to common earth dully all as specified and directed by Engineer-in-Charge. Note: 4 runs of 6 Sqmm copper wire, one run of 6 Sqmm copper wire and one run of PVC conduit shall be measured as one unit.
S&F, suspended architectural LED luminaire 36 W including PVC three core flexible copper conductor cable from ceiling rose to connector of fitting with end cap complete all as specified and directed by Engineer-in-Charge. Make: Havells Cat No. DESTG250LP / S36WLED857SWH1130 or equivalent in Crompton Greaves / Philips / Bajaj / Wipro. Note: The quoted rate shall be deemed to include the cost of suspension system.
S&F, LED tube light 1 x 20 W 4 feet long wall mounted anodized aluminium extruded head provided for efficient heat dissipation and integrated and interchangeable integrated electronic driver luminaries LED as light source housing complete with all accessories including suitable 20W polycarbonate tube rod including pre wire and including up with twin core twisted flexible copper cable of suitable size all as per specified and as directed by Engineer-in-Charge. Make: Havells Cat No. STREAKT8UPTO1X22WDSBSWH or equivalent in Crompton / Phillips / Bajaj / Wipro.
S&F, LED 36 W 2' x 2' environmental friendly, new eneration, aesthetically designed, ultra modern recess mounting luminaire with high brightness complete all as specified and directed by Engineer-in-Charge. Make: Havells Cat No. VENUSNEOHE 2X2R36WLED857 PIRSENSOR or equivalent in Crompton / Phillips / Bajaj / Wipro.
S&F, LED 36 W 2' x 2' flat panel for surface mounting luminaire with high brightness complete all as specified and directed by Engineer-in-Charge. Make: Havells Cat No. PLANOSURFACE2X2PLS36WLED857S or equivalent in Crompton / Phillips / Bajaj / Wipro.
S&F, energy saving and environmental friendly long life LED street light, 40 watt made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having IP-65 protection and impact resistance of IK07 with 10 kV Built-in Surge Protection Device complete all accessories as per directed by Engineer-in-Charge. Make: Havells Cat No. ENDCITYLITEPLAT+SL40WLED757PASYBOPCWOSPD or equivalent in Crompton / Phillips / Bajaj / Wipro.
S&F, suitable shape street light fitting bracket made out of GI Pipe 40 mm dia med grade or of suitable size as per requirement and shape, clamps made out from MS flat of size 40 mm x 6 mm with nuts and bolts (length of pipe should not less than 1.5 m) complete all as specified and directed by Engineer-in-Charge.
S&F, surface mounted LED downlighter 18 W with white powder coated aluminium housing with integrated electronic driver all as specified and directed by Engineer-in-Charge. Make: Havells. Cat No. ENDURANEOHESURFACEDLS18WLED857S or equivalent in Crompton / Phillips / Bajaj / Wipro.
S&F, load line distribution board, TPN vertical, 4 way double door type, fixed on wall semi flush, bus-bars, neutral link, blanking plates with incommer MCCB 4 pole 63 A, 18 KA complete all as specified and directed by Engineer-in-Charge. Note: MCB's for out goings shall be measured and paid for separately under relevant items.
S&F, SPN distribution board, double door flush type all as per IS 8623 made from sheet metal duly powder coated 8 way to be fixed flush with wall complete with all accessories all as specified and directed by Engineer-in-Charge. Note: MCB's for out goings shall be measured and paid for separately under relevant items.
S&F, load line distribution board, TPN vertical, 8 way double door type, fixed on wall semi flush, with incoming MCCB 4 pole, 250 Amps, 36 KA, bus-bars, neutral link, blanking plates complete all as specified and directed by Engineer-in-Charge. Note: MCB's for out goings shall be measured and paid for separately under relevant items.
S&F, connecting and testing MCB three pole and neutral (MCB TPN) 440 volts, of capacity 16 to 63 Amps, 10 kA 'C' curve complete all as specified and directed by Engineer-in-Charge.
S&F, connecting and testing MCB single pole and neutral (MCB SPN) 230 volts, of capacity 32 Amps, 10 kA 'C' curve complete all as specified and directed by Engineer-in-Charge.
S&F, connecting and testing MCB single pole (MCB SP) 220 volts of capacity 6 to 32 Amps, 10 kA 'C' curve complete all as specified and directed by Engineer-in-Charge.
S&F, flame proof / weather proof LED well glass light fitting suitable for 45 Watt with lumen out put not less than 4400 Lumens, body made out of aluminium alloy LM-6 body epoxy painted with wire guard relfector, flame proof Heat Resistant Clear Toughened ‘Type‐A’ with Led chip - Osram smd / Citizen / Epistar including suitable electronic including necessary fixing arrangments and connecting up completely all as Gas Gr. IIA, IIB Certified by CMRI Dhanbad & CCOE (PESO) Nagpur along with ISI marking glass complete all as specified and directed. Make: Shyaam switch gear Cat part SSPL/1233 / Flexpro / Baliga / Sudhir / Bajaj / Crompton.
S&F, flame proof switch of LM 6 body, rotary switch, SP, 16 Amps for ON / OFF light / fan point to operate on single phase 230 Volts, AC CMRI certified IS-2145 complete all as specified and directed. Make: Shyaam switch gear Cat part SSPL/2C/1010 / Flexpro / Baliga / Sudhir / Bajaj / Crompton.
S&F, flame proof switch socket combination suitable for 2P+E 16 Amps, 250 volts including plug and top, LM-6 body, CMRI certified, ISI marked all as specified and directed by Engineer-in-Charge. Make: Shyaam switch gear Cat part SSPL/2C/1010 / Flexpro / Baliga / Sudhir / Bajaj / Crompton.
S&F, flame proof switch socket combination suitable for 2P+E 25 Amps, 250 volts including plug and top, LM-6 body, CMRI certified, ISI marked all as specified and directed by Engineer-in-Charge. Make: Shyaam switch gear Cat part SSPL/2C/1010 / Flexpro / Baliga / Sudhir / Bajaj / Crompton.
Taking down fan, sealing cable end, dismantling blades and removing fan and blades to store complete all as specified and directed.
Refixing ceiling fan and connecting up including providing of cable from ceiling rose or connector to fan complete all as specified and directed.
Taking down exhaust fan / FLP exhaust fan, sealing cable end, dismantling blades and removing fan and blades to store complete all as specified and directed.
Refixing exhaust fan / FLP exhaust fan and connecting up including providing of cable from ceiling rose or connector to fan complete all as specified and directed.
Supply, installing, testing and commissioning of LT feeder panel box indoor type, made out of CRCA sheet 2.0 mm thick, cubical type water / weather proof, factory made with front opening type, suitable for 415 volts, 3 phase, 4 wire, 50 Hz, AC supply, having 03 Nos aluminium bus bars of 400 Amps and neutral bus bar of 400 Amps capacity duly insulated with heat shrinkable colour coated sleeve complete, painted with powder coated with pure polyster, 60 microns thickness RAL-7032 code with locking arrangement, mounted on base angle iron 50 x 50 x 5mm wall mounted type including grouted with PCC foundation all as specified and directed. The LT feeder panel box provided with the following accessories: (to be fixed in 2nd floor) (a) MCCB, 415 volts, 4 pole, 36 KA rupturing capacity of 250 Amps - 1 No. (As Incoming). (b) MCCB, 415 volts, 4 pole, 16 KA rupturing capacity of 63 Amps - 5 Nos. (As outgoing) (c) Digital multi function meter for Amp, Volt, KWH, power factor and other parameter flush mounting of size 96 x 96 mm and 3 Nos of CTs class 1.0, 10VA - 01 Set. (d) Indicating lamps R, Y, B - LED with switch control - 03 Nos.
M&L for earthing complete with galvanised steel earth plate electrode 60 x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to galvanised iron strip 32 x 6mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion all as specified and directed by Engineer-in-Charge. Note: The quoted rate shall be deemed to include the cost of GI earth strip 32 x 6mm upto 7.5m length.
M&L for earth contunity conductor or main earthing lead fixed to wall on recessed or burried in ground or drawn in conduit / pipe fixed to poles or any other indicated situation for loop earthing as required 32 x 6 mm size galvanised strip complete all as specified and directed. Note: All GI strip joints shall be butt welded atleast 50mm long.
M&L for sub main wiring with 2 runs of 6 Sqmm single core, multistranded PVC insulated unsheathed cable 1100 volts grade with copper conductor, drawn through and including concealed PVC conduit pipe with one run of 1 x 6.0 Sqmm PVC insulated unsheathed copper conductor cable as earth continuity conductor and connecting to common earth dully and making good disturbed surface of wall, roof and floor etc all as specified and directed by Engineer-in-Charge. Note: 2 runs of 6 Sqmm copper wire, one run of 6 Sqmm copper wire and one run of PVC conduit shall be measured as one run.
LIGHTENING PROTECTION Taking down / dismantling existing perished aluminium strip of size 25 x 3 mm from any height of roof top / on walls of conventional type lightening protection network system complete all as specified and directed.
Taking down / dismantling existing perished GI strip of size 32 x 6 mm from on walls / buried in to ground of conventional type lightening protection network system complete all as specified and directed.
Taking down existing air termination, single pointed aluminium rod 12mm dia and 300mm long complete all as specified and directed.
Taking down existing unserviceable test point terminal block complete all as specified and directed.
S&F, air termination single pointed aluminium rod of 12mm dia 300mm long complete all as specified and directed by Engineer-in-Charge.
S&F, test point terminal block made of gun metal or phosphorus bronze size 75 x 75 x 25mm, drilled and screwed including, 03 Nos, 8mm dia, 25mm long hex, head screw complete all as specified and directed by Engineer-in-Charge.
S&F, aluminium strip 25 x 3mm with saddle and fixing screws etc for roof conductors and down conductors above ground level fixed on walls / roof with all neccesary fixing arrangements complete all as specified and directed by Engineer-in-Charge. Note: Epoxy base insulator only will be measured and paid seperately.
S&F, epoxy base insulator suitable size 35 mm height fixed on PCC blocks / on wall on MS angle / on towers with and including nut, bolts and washers etc complete all as specified and directed by Engineer-in-Charge.
M&L for PCC block of size 150 x 150 x 150mm in PCC (1:3:6) type C-1 with 20mm stone graded aggregate including necessary form / mould for fair and even surfaces, air termination rod / GI strip etc., complete all as specified and directed by Engineer-in-Charge.
M&L for GI tubing light grade of size 40 mm bore for connecting to air termination rod / protection to GI strip including brackets for fixing complete all as specified and directed.
S&F, earth pit indicator made out of MS sheet of 16SWG of size 30 x 20cm welded to angle of size 25 x 25 x 3mm at a height 1M above ground including dismantling taking out old earth pit indicator complete all as specified and directed by Engineer-in-Charge.
S&F, inspection boxes / test point boxes 250 x 150 x 100 mm made out of 16 gauge MS sheet with top cover including provisioin of fixing of 02 Nos epoxy insulator with and including insulating PVC sheet for incoming and outgoing copper strip for proper insulation etc, complete all as specified and directed by Engineer-in-Charge.
INCOMING a) Air circuit breaker 4 pole, 800 Amps, thermal magnetic based, manual draw out with overload short circuit, 415Volts, 50KA, 50Hz - 01 No. b) Digital Multi Function Meter (A, V, Z, PF, KW, KVA) - 01 No. c) Indication lamp R, Y, B LED type set of three - 01 No. OUTGOING a) MCCB, 3 pole, 400 Amps, 440 Volts, rupturing capacity 36 KA, adjustable overload type 80-100% with thermal magnetic release, Ics = 100%, Icu - 01 No. b) MCCB, 3 pole, 250 Amps, 440 Volts, rupturing capacity 36 KA, adjustable overload type 80-100% with thermal magnetic release, Ics = 100%, Icu - 05 Nos. c) MCB TPN 32 Amps, 10 KA, 'C' type - 02 Nos. d) MCB SPN 32 Amps, 10 KA, 'C' type - 02 Nos. e) Digital Ammeter (0 to 1000 Amps) - 06 Nos. f) Indication lamp R, Y, B LED type set of three - 06 Nos.
Taking down existing old version LT panel out door type including disconnecting of incoming / outgoing UG cables complete all as specified and directed.
Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 300 sq mm 3.5 core complete all as specified and directed.
Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 240 sq mm 3.5 core complete all as specified and directed.
Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sq mm 3.5 core complete all as specified and directed.
Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3.5 core complete all as specified and directed.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr deep for taking out / laying of LT under ground cable and getting out in soft / loose soil complete all as specified and directed by Engineer-in-Charge.
All as per Sl item No. 220 above but, soft / disintegrated rock.
Removing surplus excavated soil to a distance not exceeding 50m depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed by Engineer-in-Charge.
Supply & lay in trenches un-reinforced precast concrete cable cover class LV type 1 flat size 250 x 150 x 40 mm for cable protection all as specified and directed by Engineer-in-Charge.
M&L for sand (stone crushed sand) in cable trenches as cushioning to cables including spreading and punning down all as per clause No. 3.21 of SSR Part - I (2009) complete all as specified and directed by Engineer-in-Charge. Note: Punned thickness shall be measured and paid.
M&L for 100mm GI tube, light grade with all fittings, complete, fixed to walls, pole ceiling or laid in trenches for cable protection including removing of old unserviceable pipe of any size all as specified by Engineer-in-Charge. Note: Excavation and earth work where required shall be measured separately. MS clamps for fixing on wall / pole etc, are included in the unit rate.
M&L for 80mm GI tube, light grade with all fittings, complete, fixed to walls, pole ceiling or laid in trenches for cable protection including removing of old unserviceable pipe of any size all as specified by Engineer-in-Charge. Note: Excavation and earth work where required shall be measured separately. MS clamps for fixing on wall / pole etc, are included in the unit rate.
M&L for 40mm GI tube, light grade with all fittings, complete, fixed to walls, pole ceiling or laid in trenches for cable protection including removing of old unserviceable pipe of any size all as specified by Engineer-in-Charge. Note: Excavation and earth work where required shall be measured separately. MS clamps for fixing on wall / pole etc, are included in the unit rate.
M&L for cutting of roads / plinth for removal / laying of pipe and making good the disturbed surfaces as per existing adjoining surfaces complete all as specified and directed by Engineer-in-Charge.
M&L for PCC 1:2:4 type B-1 using 20mm graded crushed stone aggregate as in foundations of for making good road / foot path / hard standing / drain / bldg plinth protection complete all as specified and directed by Engineer-in-Charge.
AIR CONDITIONING Supply & install, inverter technology split units indoor / outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with copper condeser green gas with minimum 5 star rating and EER 3.3 of capacity 1.5 TR complete all as specified and directed by Engineer-in-Charge. Make: Voltas / Bluestar / Daikin / Carrier / Hitachi.
S&F, voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA complete all as specified and directed by Engineer-in-Charge. Make: V Guard / Automatic Electric / Vinitec / Aplab / Volina / Indian Transformer and Electricals / Emerson / Andrewyule.
S&F, single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole, MCB 20 Amps, 240 volts complete all as specified and directed.
Taking down shutters of any description exc 1 Sqm but n.exc. 2 Sqm each and refixing in same opening after resecuring, easing etc complete all as specified and directed.
SLB Enterprises
tulsani associates
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .