Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.1 LAdmitted-Finance | ₹16.1 L | L1 | Admitted-Finance |
| Sl No | Description | Qty | Unit | GD ENTERPRISES L1 |
|---|---|---|---|---|
| 1.00 | SITC of 2.0 TR Window Air Conditioners with all accessories and ambient upper temperature range of >= 52 degree Celsius for cooling with Maximum cooling capacity >= 6500 W and having Air Flow Rate >=590 cfm with minimum 3 star rating and of reputed make along with allied accessories . Complete job as per site requirement and instructions of Engineer-in-charge and also includes cost of materials, labour charges, transportation charges and all other charges and taxes | 12 | no. | 54,000 ₹6,48,000 Lowest |
| 2.00 | SITC of Wall mounted Copper wound stabilizer for 02 TR Air conditioners of capacity 5 KVA (voltage range 90 volts-300 volts ) of reputed Make i.e. Electricfield/Servocon/Aulten/ Microtek /V guard along with allied accessories. Complete job as per site requirement and instructions of Engineer-in-charge and also includes cost of materials, labour and all types of taxes etc | 12 | no. | 9,050 ₹1,08,600 Lowest |
| 3.00 | Providing and laying of (using conduits and wire fasteners / cable clips/conduit fasteners) 4 sq mm ISI Marked, FRLS PVC insulated copper conductor cable of standard make i.e. Havells, Polycab, Finolex, Anchor only for the purpose of connecting air conditioning units to the Stablizer. Complete job as per instructions of Engineer-in-charge and site requirements and also includes cost of materials (including PVC pipes 1”, clamps, bends/elbows, Tee-bends, thimbles etc.), labour charges, transportation charges and all other charges and taxes etc. | 1 | job | 19,990 ₹19,990 Lowest |
| 4.00 | Providing and laying of PVC drain pipes of assorted sizes viz. ¾”, etc. to collect and transport the drained water from the AC unit to a designated location, considering the specific requirements of the site. The PVC pipes will be installed with appropriate size bends and clamps to ensure proper alignment and secure connections. Job also Includes miscellaneous works Civil works like wall opening to pass ducts & pipes, plastering & refinishing of the same to the original finish as per the site requirements. The job includes Providing and Fitting of SPN 40 Amp Box type -12 No’s . Complete job as per instructions of Engineer-in-charge and site requirements and includes cost of materials (including clamps, bends/elbows, nipples, Tee-bends, etc.), labour charges, transportation charges and all other charges and tax | 1 | job | 16,000 ₹16,000 Lowest |
| 5.00 | Supplying & laying of PVC insulated and PVC sheathed/ XLPE Aluminium power cable of 1.1 KV grade of following size on surfaces/ direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. (Armoured cable)
150 sq. mm 3.5 core | 250 | mtrs | 1,500 ₹3,75,000 Lowest |
| 5.10 | Supplying & laying of PVC insulated and PVC sheathed/ XLPE Aluminium power cable of 1.1 KV grade of following size on surfaces/ direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. (Armoured cable)
70 sq. mm 3.5 core | 30 | mtrs | 800 ₹24,000 Lowest |
| 6.00 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required
3.5X70 sq mm | 4 | no. | 420 ₹1,680 Lowest |
| 6.10 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required
3.5X150 sq mm | 4 | no. | 620 ₹2,480 Lowest |
| 7.00 | Supply, installation, testing & commissioning of maintenance free copper earthing system with 3 mtrs. Electrode 40 mm dia with minium 2mm thick and does not require manual additional of water. The electrode shall be pre-filled with hygroscopic powder and provided with suitable breathing and leaching ports at the ends. the electrode shall be surrounded by suitable powdered form of BEE MOIST so as to provide maximum contact between the electrode and the compund. The compound should be eco-friendly The earthing pit should be covered with PVC cover. | 1 | set | 13,400 ₹13,400 Lowest |
| 7.10 | Providing and fixing of 25 mm x 5 mm copper strip on surface or in recess for connections etc. as required. | 10 | mtrs | 1,040 ₹10,400 Lowest |
Tender Value
₹18.0 L
EMD Value
₹36,500
Closing Date
30 Dec 2025, 4:00 pmClosed
XEN MECHANICAL AND HOSPITAL DIVISION JAMMU
XEN MECHANICAL AND HOSPITAL DIVISION JAMMU
Upgradation and Strengthening work of Physiotherapy Department by Air conditioning and allied works at GMC, Jammu
2025_PWDJK_297606_1
MHDJ/e-NIT 284 of 2025-26
Open Tender
Machineries/ Mechanical Engg Items
Turn-key
45 days
GMCH JAMMU
as per e nit
2 documents required · 2 mandatory
₹1,000
XEN MECHANICAL AND HOSPITAL DIVISION JAMMU
₹36,500
12 Jan 2026
8 Dec 2025
31 Dec 2025
8 Dec 2025
30 Dec 2025
13 Dec 2025
8 Dec 2025 - 19 Dec 2025
SITC of 2.0 TR Window Air Conditioners with all accessories and ambient upper temperature range of >= 52 degree Celsius for cooling with Maximum cooling capacity >= 6500 W and having Air Flow Rate >=590 cfm with minimum 3 star rating and of reputed make along with allied accessories . Complete job as per site requirement and instructions of Engineer-in-charge and also includes cost of materials, labour charges, transportation charges and all other charges and taxes
SITC of Wall mounted Copper wound stabilizer for 02 TR Air conditioners of capacity 5 KVA (voltage range 90 volts-300 volts ) of reputed Make i.e. Electricfield/Servocon/Aulten/ Microtek /V guard along with allied accessories. Complete job as per site requirement and instructions of Engineer-in-charge and also includes cost of materials, labour and all types of taxes etc
Providing and laying of (using conduits and wire fasteners / cable clips/conduit fasteners) 4 sq mm ISI Marked, FRLS PVC insulated copper conductor cable of standard make i.e. Havells, Polycab, Finolex, Anchor only for the purpose of connecting air conditioning units to the Stablizer. Complete job as per instructions of Engineer-in-charge and site requirements and also includes cost of materials (including PVC pipes 1”, clamps, bends/elbows, Tee-bends, thimbles etc.), labour charges, transportation charges and all other charges and taxes etc.
Providing and laying of PVC drain pipes of assorted sizes viz. ¾”, etc. to collect and transport the drained water from the AC unit to a designated location, considering the specific requirements of the site. The PVC pipes will be installed with appropriate size bends and clamps to ensure proper alignment and secure connections. Job also Includes miscellaneous works Civil works like wall opening to pass ducts & pipes, plastering & refinishing of the same to the original finish as per the site requirements. The job includes Providing and Fitting of SPN 40 Amp Box type -12 No’s . Complete job as per instructions of Engineer-in-charge and site requirements and includes cost of materials (including clamps, bends/elbows, nipples, Tee-bends, etc.), labour charges, transportation charges and all other charges and tax
Supplying & laying of PVC insulated and PVC sheathed/ XLPE Aluminium power cable of 1.1 KV grade of following size on surfaces/ direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. (Armoured cable) 150 sq. mm 3.5 core
Supplying & laying of PVC insulated and PVC sheathed/ XLPE Aluminium power cable of 1.1 KV grade of following size on surfaces/ direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. (Armoured cable) 70 sq. mm 3.5 core
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required 3.5X70 sq mm
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required 3.5X150 sq mm
Supply, installation, testing & commissioning of GI Electrode Earthing with 50mm dia and 3 meter length, with 3mm thick the electrode should be hot-dip galvinised. The GI Electrode shall be pre-filled with Cristaline Conductive Materila (CCM). The GI electrode shall be surrounded with BEE MOIST compound to provide maximum contact betwen the electrode and compound should be eco-friendly GI Electrode Earthing should be maintinance free and does not require regular manual addition of water . The earthing pit should be covered with PVC cover
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
SITC of wall/free standing floor mounted dust and vermin proof compartmentalized cubical panel for electrical Works, made out of CRCA sheet. Other parameters required as per point (a) Thickness of sheet shall not be less than 1.6 mm up to 600 mm length/width of any compartment and be of 2.0 mm above 600 mm. Load bearing structure shall be of 2.0 mm thick sheet supported by base M.S. channel if required. Side walls and cable alley compartment shaving bolted type doors with/without detachable extension type structure (b) Panel shall be duly treated for derusting in 7 tank process with de phosphating and with powder coating of minimum 70 microns on both side of panel in desired shade The panel having PU/Neoprene rubber gasket of not less than 3mm thickness, required hardware, separate detachable gland plate M.S. base channel (min 75mm), hinged door with locking arrangement for equipment/switchgear c) Interconnection between bus bar and switch gears/cable shall be rigidly supported and made out by flexible copper wires (upto 125 amp) and by solid bus bar (> 125). (d) Only outer area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator CPRI Test certificates to be submitted) All as per pre approved by Engineer in charge
stage.html
html • 0.02 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.82 MB
BOQ_964615.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .