Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.4 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹42.5 L+₹1.5 L (3.57%)Rejected-Finance MAKARDHA PO MAKARDHA PS DOMJUR BANERJEEPARA WEST BENGAL 711409 | HOWRAH | WEST BENGAL | 711409 | L2 | Rejected-Finance Unsuccessful bidder | |
| 3 | L3₹43.1 L+₹2.0 L (4.89%)Rejected-Finance | L3 | Rejected-Finance Unsuccessful bidder | |
| 4 | L4₹43.8 L+₹2.7 L (6.66%)Rejected-Finance | L4 | Rejected-Finance Unsuccessful bidder | |
| 5 | L5₹50.4 L+₹9.3 L (22.7%)Rejected-Finance C O KALIPADA MITRA SOUTH BHARAT NAGAR NEAR JAGDISH CHANDRA HIGH SCHOOL SILIGURI DISTT DARJEELING WB 734004 | JALPAIGURI | WEST BENGAL | 734004 | L5 | Rejected-Finance Unsuccessful bidder |
Tender Value
₹40.5 L
EMD Value
₹81,000
Closing Date
17 Oct 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF Bagdogra
GE AF Bagdogra Bagdogra Airport PO, Dist Darjeeling, WB - 734421
ADDN/ ALTN OF ATC TOWER GLASS IN BLDG NO P-113 AT 20 WING, AFS AND CONSTRUCTION OF DRAINAGE AT MT WASHING BAY AT 273 SU, AF STN BAGDOGRA UNDER GE (AF) BAGDOGRA
2023_MES_619571_1
8517/E8
Open Tender
Civil Works
Item Rate
180 days
GE AF Bagdogra
As per NIT
8 documents required · 8 mandatory
₹500
GE AF Bagdogra
₹81,000
Yes
8 Nov 2023
19 Sept 2023
18 Oct 2023
19 Sept 2023
17 Oct 2023
3 Oct 2023
Amount
Addn/Altn to ATC Tower Glass Removing of existing vacuum filled tinted double layered hermetically sealed window glass including its necessary frame work and making good condition of the disturbed surface for fixing new frame complete all as specified and directed.
S&F 24mm thick vacuum filled double layered hermetically sealed clear toughened glass (6mm thick clear toughened glass +12mm thick vacuum filled +6mm thick clear toughened glass) including necessary rubber beading/ gasket and sealing compound as required for fixing/ sealed the glass complete all as specified and directed. Note:- (i) The glass panes should consist of single panel from wall to roof separated with vertical frame work for support. The joining between the glass pane and frame work should be properly sealed to prevent seepages. (ii) Aluminium frame work shall be measured and paid separately under appropriate item. (iii) Size of each glass pane/panel shall be ___ Sqm (approx).
S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS:733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gape at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ panelling, C.P. brass/ stainless steel screws complete all as specified and directed.
Taking down chowkhat or frame with shutter (without taking off shutter from the frame) area not exc 1.5 Sqm each including making good the disturbed surfaces of wall etc to match with existing adjoining surfaces complete all as specified and directed.
Taking down chowkhat or frame with shutter (without taking off shutter from the frame) area exc 1.5 Sqm but n.exc 4 Sqm each including making good the disturbed surfaces of wall etc to match with existing adjoining surfaces complete all as specified and directed.
S&F Powder coated aluminium sliding window shutters with frames (consisting of 02 Nos glazed shutters) Series-D (25mm), 2 track sliding shutters, duly fitted with neoprene beading, glazing clips, locking device, 5.50 mm thick heat absorbing glass, in glazed shutters, complete all as specified and directed. Note:- The cost of glass shall deemed to be included in the quoted rate.
S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) door shutters, aluminium section weighing not less than 0.55 Kg/m including necessary joining cleats, glazing clips, rubber neoprene pacing, powder coated aluminium fittings such as handles 02 Nos, 100 mm long hinges 03 Nos, sliding bolt 01 Nos, tower bolt 02 Nos in each door, powder coated aluminium snap beading and rubber gasket, screws etc complete all as specified and directed. Note:- Glass shall be measured separately.
S&F 5.50 mm thick heat absorbing glass, ordinary quality and glazing with rubber beading, cleats in necessary to aluminium door of any size complete all as specified and directed.
S&F Aluminium (Die cast body) door closer hydraulically regulated designation No 3 universal type suitable for door shutters of 851 to 1000mm in width and of weight between 61 to 80 Kg complete all as specified and directed.
S&F solid PVC wall lining consisting of 5mm thick wood grain printed PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing etc complete all as specified and directed.
S&F 5mm thick PVC sheet fillet of width 35mm for wall panelling inclusive of fixing on to wall to make PVC frame as per specification and drawing complete all as specified and directed.
M&L for taking down existing wooden flooring and providing 8mm thick wooden flooring consisting of panels of approved size or as per manufacturer specification, having class of use 23/33, wear resistance level of AC 5 as per EN 13329 with a high resistant surface impregnated with melamine resins and aluminium oxide and high density fibre board of E1 standards. The panels having a click system tongue and groove joint to secure a long lasting joint with the edges duly impregnated with paraffin. The Floating laminate flooring shall be laid over a 0.20 mm thick polythene film to form a vapour barrier and 2mm to 3mm thick approved FOAM. The panels used shall be of high solidity, high impact strength, high temperature resistance without change in shape. Each panels shall have click system (tongue and groove profile) and to be laid in approved pattern with suitable glue as per manufacturers specifications including around suitable edge profile around/ wherever required for firm and licking. The timber floor shall be resistant to impact, abrasion, stains, fade cigarette burns and house hold chemicals. The quoted rate shall include the cost of laying, wastage, glue, loading, unloading and all applicable taxes complete all as specified and directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards/ slabs etc any thickness including cover fillets complete all as specified and directed.
S&F Powder coated galvanised iron snap grid frame work of size 600 x 600mm for false ceiling comprising of main runner 'T' section of size 38mm x 24mm x 0.30mm thickness, cross 'T' of size 24mm x 25mm x 0.3mm thickness and wall angle of size 24mm x 24mm x 0.40mm thick suspended with 4mm dia GI wire from purlin @ 1.20m centre to centre complete all as specified and directed.
S&F 12mm thick Perforated false ceiling board/ tiles for insulation and acoustic purposes, 60x60 cm in size, fixed on snap grid false ceiling complete all as specified and directed.
Construction of drainage at MT Washing Bay Excavation in trenches n.exec 1.5m width and n.exc 1.5m depth and getting out in Soft/ loose soil complete all as specified and as directed.
Returning and filling in with soil obtained from excavation in laying n.exc 25cm thick including watering ramming etc. complete all as specified and as directed.
Removal of excavated spoil of soil to a distance n.exc 50 mtr and deposited complete all as specified and as directed.
M&L for PCC 1:4:8, type D-2 (using 40mm graded stone aggregate) as in foundation complete all as specified and as directed.
M&L for RCC M-30 DM (using 20mm graded stone aggregate) as in foundation including raft, footings, foundations beams, plinth beams, bases for columns etc. basement slab, under reemed piles and mass concrete complete all as specified and as directed.
M&L for RCC M-30 DM (using 20mm graded stone aggregate) as in walls, retaining walls, basement walls and the like any thickness above top of footings including attached pilasters and buttresses, complete all as specified and as directed.
M&L for form work to sides of concrete foundation work vertical or to batter for rough finished surfaces of concrete (flat) complete all as specified and as directed.
M&L for form work to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pilasters, buttresses etc. vertical or to batter for fair finished surfaces of concrete (flat) complete all as specified and as directed.
M&L for PCC 1:2:4, type B-1 (using 20mm graded stone aggregates) as in landing, cover slab (for main holes etc.) chullah hoods, chajjas, water troughs, managers, shelves and similar articles with plain faces set in CM (1:4) complete all as specified and as directed.
M&L for Fe-500 TMT bars 6mm dia to 8mm dia cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and as directed.
M&L for Fe-500 TMT bars 10mm dia and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
M&L for Framed work such as grills, gratings etc. with ends of bars shouldered and/ or riveted or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; frame work of water tanks and similar work conforming to Fe 290 Gde - E - 165 complete all as specified and as directed.
Excavating over areas, n.exc 1.5m deep and getting out in Soft/ loose soil complete all as specified and as directed.
M&L for hard core of gauge not exc 63mm deposited, spread and levelled in layers not exc 15cm thick watered and rammed to a true surfaces with broken stone or boulders complete all as specified and as directed.
M&L for PCC 1:3:6, type C-2 (using 40mm graded stone aggregate) as in surface channel and drains complete all as specified and as directed.
M&L for brickwork with sub class 'B' bricks, straight or curved on plan exc 6m mean radius built in CM 1:4 complete all as specified and as directed.
M&L for 15mm thick, rendering on fair faces of brick work or concrete surfaces built in cement mortar 1:6 finished even and smooth in wall complete all as specified and as directed.
NOTES :- 1. The amount of schedule of credit shall be deducted from the total of this BOQ for arriving at contract sum.
M/S Banerjee construction co
SREE SWAPAN KUMAR GHOSH
INDIA DEVELOPMENT CONSTRUCTION
M/S MANAS MITRA
SUNIL DAS AND CO
M/S IDEAL CONSTRUCTIONS
NIRANJAN SARKAR
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .