Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.8 LAccepted-AOC 1501 BHAGWATI EMINENCE SAVITRIBAI PHULE MARG BESIDES R R PATIL GARDEN SECTION 13 NERUL E NAVI MUMBAI | RAIGAD | MAHARASHTRA | 400702 | L1 | Accepted-AOC Admitted being L1 | |
| 2 | L2₹46.0 L+₹2.2 L (5.13%)Rejected-Finance FLAT NO 201 GREEN VALLEY CHS PLOT NO 26 SECTOR 19 NERUL EAST NAVI MUMBAI 400 706 | THANE | MAHARASHTRA | 400706 | L2 | Rejected-Finance Not admitted being L2 | |
| 3 | L3₹46.7 L+₹2.9 L (6.67%)Rejected-Finance 203 NIVAAN LAXMI SOCIETY PLOT NO 169 SECTOR 19 KHARGAHAR NAVI MUMBAI 410210 | RAIGAD | MAHARASHTRA | 410210 | L3 | Rejected-Finance Not admitted being L3 | |
| 4 | L4₹47.6 L+₹3.8 L (8.70%)Rejected-Finance SHOP NO 106 1ST FLOOR ASHOKA SHOPPING CENTRE LT ROAD MUMBAI 400001 | MUMBAI | MUMBAI | MAHARASHTRA | 400001 | L4 | Rejected-Finance Not admitted being L4 | |
| 5 | L5₹48.7 L+₹5.0 L (11.3%)Rejected-Finance SHOP NO 12 KHOPKAR APARTMENT KUMBHARAWADA URAN DISTT RAIGAD 400 702 | URAN | RAIGAD | MAHARASHTRA | 400702 | L5 | Rejected-Finance Not admitted being L5 |
| Sl No | Description | Qty | Unit | M.K Enterprises L2 | pk Enterprises L4 | Nexus Infratech L6 | SREE HARITHA ASSOCIATES L1 | ENJOY L5 | R A Electric Co. L8 | Tripura Engineers L7 | BALAJI TRADERS L3 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply, installation, commissioning and testing of factory made, CPRI type tested, indoor, cubical compartmental type HVAC Panel in replacement of HVAC Panel DBM 16 AC plant suitable size, having both sides openable with hinged double doors & locking arrangement and IP 42 protection made out of 2.0 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labeling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel sheet, vitreous enameled (white) with letters figures and conventional skull and bones in signal red colour, suitable for 3- Phase 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length & size, including fixing lugs, bolts, screws etc. complete with accessories as and as directed by Engineer-in-charge, Make: CPRI approved panel builder. The HVAC Panel shall comprising of the following provisions:-
Bus bar Chamber:
INCOMER:-
[i] 01 Set (3L + N) of copper bus bar of rated capacity 320 Amp, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connection Incoming:[ii] 250 A, 415 V, Ics = 100% Icu = 26 kA, 50 Hz FP MCCB, conforming to IEC 60947-2, having thermal magnetic based trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (Ready, Overload and pre-alarm & Overload), etc.- 01 Nos.
[ii] Cl 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Run hrs. On hrs & interupts01 Nos.
[iii] LED phase indicators (Red, Yellow, Blue) - 01 Set
Outgoing:
[i] 100 A, 415 V, Ics = Icu = 16 kA, conforming to IEC 60947- 2, 50 Hz, FP MCCB with adjustable thermal settings & fixed magnetic settings with compression lug connectors and thermal magnetic trip unit (TMD)- 03 Nos. [for chillers] | 1 | Each Job | 3,83,669 ₹3,83,669 | 3,85,221 ₹3,85,221 | 3,77,613 ₹3,77,613 | 3,20,000 ₹3,20,000 Lowest | 3,80,000 ₹3,80,000 | 3,81,553 ₹3,81,553 | 3,50,000 ₹3,50,000 | 3,79,337 ₹3,79,337 |
| 1.01BoQ Serial Item No.1.00 Contd - [ii] 63 A, 415 V, Ics = Icu = 16 kA, conforming to IEC 60947- 2, 50 Hz, FP MCCB with adjustable thermal settings (0.70- 1 X In) & fixed magnetic settings with compression lug connectors and thermal magnetic trip unit (TMD)- 01 Nos. [for AHU] [iii] 25 A, 415 V, Ics = Icu = 16 kA, conforming to IEC 60947- 2, 50 Hz, FP MCCB with adjustable thermal settings & fixed magnetic settings with compression lug connectors and thermal magnetic trip unit (TMD)- 02 Nos. [for condenser pump] (iv) 20 A, 415 V, Ics = Icu = 16 kA, conforming to IEC 60947- 2, 50 Hz, FP MCCB with adjustable thermal settings & fixed magnetic settings with compression lug connectors and thermal magnetic trip unit (TMD)- 03 Nos. [for Cooling tower & 02 Spare] (v) Fully automatic DOL starter, complete with contactors, push button, LED type indicators, auto/manual selector switch, overload protection, current sensing type single phase preventer complete with all accessories and wiring etc-total 01 Nos. (Cooling tower motor capacity 3 HP - 01 Nos) (vi) Fully automatic Star Delta Starter, complete with contactors, push button, LED type indicators, auto/manual selector switch, overload protection, current sensing type single phase preventer complete with all accessories and wiring etc-total 02 Nos (condenser pump capacity 5 HP - 02 No) [vii] LED phase indicators (Red, Yellow, Blue)- 8 Set , [viii] Cl 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Run hrs. On hrs & interupts10 Nos. | |||||||||||
| 2.00 | Supply, installation, commissioning and testing of factory made, CPRI type tested, indoor, cubical compartmental type HVAC Panel in replacement of HVAC Panel DBM 17 AC plant suitable size, having both sides openable with hinged double doors & locking arrangement and IP 42 protection made out of 2.0 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labeling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel sheet, vitreous enameled (white) with letters figures and conventional skull and bones in signal red colour, suitable for 3- Phase 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length & size, including fixing lugs, bolts, screws etc. complete with accessories as and as directed by Engineer-in-charge, Make: CPRI approved panel builder. The HVAC Panel shall comprising of the following provisions:-
Bus bar Chamber:
INCOMER:- [i] 01 Set (3L + N) of copper bus bar of rated capacity 320 Amp, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connection Incoming:[ii] 250 A, 415 V, Ics = 100% Icu = 26 kA, 50 Hz FP MCCB, conforming to IEC 60947-2, having thermal magnetic based trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (Ready, Overload and pre-alarm & Overload), etc.- 01 Nos. [ii] Cl 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Run hrs. On hrs & interupts01 Nos. [iii] LED phase indicators (Red, Yellow, Blue) - 01 Set
Outgoing:
[i] 125 A, 415 V, Ics = Icu = 16 kA, conforming to IEC 60947- 2, 50 Hz, FP MCCB with adjustable thermal settings & fixed magnetic settings with compression lug connectors and thermal magnetic trip unit (TMD)- 02 Nos. [for chillers] | 1 | Each Job | 3,99,669 ₹3,99,669 | 4,10,557 ₹4,10,557 | 4,10,660 ₹4,10,660 | 3,16,990 ₹3,16,990 Lowest | 3,65,000 ₹3,65,000 | 4,09,700 ₹4,09,700 | 3,25,000 ₹3,25,000 | 3,87,331 ₹3,87,331 |
| 2.01BoQ Serial Item No.2.00 Contd - [ii] 63 A, 415 V, Ics = Icu = 16 kA, conforming to IEC 60947- 2, 50 Hz, FP MCCB with adjustable thermal settings (0.70- 1 X In) & fixed magnetic settings with compression lug connectors and thermal magnetic trip unit (TMD)- 01 Nos. [for AHU] [iii] 40 A, 415 V, Ics = Icu = 16 kA, conforming to IEC 60947- 2, 50 Hz, FP MCCB with adjustable thermal settings & fixed magnetic settings with compression lug connectors and thermal magnetic trip unit (TMD)- 02 Nos. [for condenser pump] (iv) 20 A, 415 V, Ics = Icu = 16 kA, conforming to IEC 60947- 2, 50 Hz, FP MCCB with adjustable thermal settings & fixed magnetic settings with compression lug connectors and thermal magnetic trip unit (TMD)- 03 Nos. [for Cooling tower & 02 Spare] (v) Fully automatic DOL starter, complete with contactors, push button, LED type indicators, auto/manual selector switch, overload protection, current sensing type single phase preventer complete with all accessories and wiring etc-total 01 Nos. (Cooling tower motor capacity 3 HP - 01 No.) (vi) Fully automatic Star Delta Starter, complete with contactors, push button, LED type indicators, auto/manual selector switch, overload protection, current sensing type single phase preventer complete with all accessories and wiring etc-total 02 Nos. (condenser pump capacity 10 HP - 02 No) [vii] LED phase indicators (Red, Yellow, Blue)- 8 Set [viii] Cl 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Run hrs. On hrs & interrupts 8 Nos. | |||||||||||
| 3.00 | Supply, installation, commissioning and testing of factory made, CPRI type tested, indoor, cubical compartmental type HVAC Panel in replacement of HVAC Panel HTL 05 AC plant suitable size, having both sides openable with hinged double doors & locking arrangement and IP 42 protection made out of 2.0 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labeling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel sheet, vitreous enameled (white) with letters figures and conventional skull and bones in signal red colour, suitable for 3- Phase 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length & size, including fixing lugs, bolts, screws etc. complete with accessories as and as directed by Engineer-in-charge, Make: CPRI approved panel builder. The HVAC Panel shall comprising of the following provisions:- Bus bar Chamber:
INCOMER:-
[i] 01 Set (3L + N) of copper bus bar of rated capacity 320 Amp, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connection Incoming:[ii] 250 A, 415 V, Ics = 100% Icu = 26 kA, 50 Hz FP MCCB, conforming to IEC 60947-2, having thermal magnetic based trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (Ready, Overload and pre-alarm & Overload), etc.- 01 Nos.
[ii] Cl 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Run hrs. On hrs & interupts01 Nos.
[iii] LED phase indicators (Red, Yellow, Blue) - 01 Set
Outgoing:
[i] 100 A, 415 V, Ics = Icu = 16 kA, conforming to IEC 60947- 2, 50 Hz, FP MCCB with adjustable thermal settings & fixed magnetic settings with compression lug connectors and thermal magnetic trip unit (TMD)- 03 Nos. [for chillers] | 1 | Each Job | 2,69,669 ₹2,69,669 | 2,93,470 ₹2,93,470 | 2,80,470 ₹2,80,470 | 2,60,000 ₹2,60,000 Lowest | 2,90,000 ₹2,90,000 | 2,86,550 ₹2,86,550 | 2,89,000 ₹2,89,000 | 2,73,881 ₹2,73,881 |
| 3.01BoQ Serial Item No.3.00 Contd - [ii] 63 A, 415 V, Ics = Icu = 16 kA, conforming to IEC 60947- 2, 50 Hz, FP MCCB with adjustable thermal settings (0.70- 1 X In) & fixed magnetic settings with compression lug connectors and thermal magnetic trip unit (TMD)- 01 Nos. [for AHU] [iii] 25 A, 415 V, Ics = Icu = 16 kA, conforming to IEC 60947- 2, 50 Hz, FP MCCB with adjustable thermal settings & fixed magnetic settings with compression lug connectors and thermal magnetic trip unit (TMD)- 02 Nos. [for condenser pump] (iv) 20 A, 415 V, Ics = Icu = 16 kA, conforming to IEC 60947- 2, 50 Hz, FP MCCB with adjustable thermal settings & fixed magnetic settings with compression lug connectors and thermal magnetic trip unit (TMD)- 03 Nos. [for Cooling tower & 02 Spare] (v) Fully automatic DOL starter, complete with contactors, push button, LED type indicators, auto/manual selector switch, overload protection, current sensing type single phase preventer complete with all accessories and wiring etc-total 01 No. (Cooling tower motor capacity 3 HP - 01 No.) (vi) Fully automatic Star Delta Starter, complete with contactors, push button, LED type indicators, auto/manual selector switch, overload protection, current sensing type single phase preventer complete with all accessories and wiring etc-total 02 Nos. (condenser pump capacity 5 HP - 02 No) [vii] LED phase indicators (Red, Yellow, Blue)- 8 Set [viii] Cl 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Run hrs. On hrs & interupts10 Nos. | |||||||||||
| 4.00 | Taking down and dismantling of existing street Light/ Flood Light / post lantern / tube light fittings any type any wattage for repair or replacement of burnt /worn out accessories and re-fixed of the same in position after repair complete all as directed by Engr-in-Charge.
Note :- (i) Accessories only wherever required shall be measured and paid separately as supply only. (ii) Labour charges for taking down and repair including minor spares like nuts, bolts , insulation materials & cleaning of area up to 1.0 m around the street light / building lights / Poles shall be deemed to be included in unit quoted rates of this item. | 220 | Each Job | 39 ₹8,580 | 23 ₹5,060 Lowest | 27 ₹5,940 | 40 ₹8,800 | 50 ₹11,000 | 37 ₹8,140 | 52 ₹11,440 | 35 ₹7,700 |
| 5.00 | Supply and fixing pressure die cast aluminium housing LED street light luminaires with IP66 of 35/45/50 Watts, complete all as specified and directed by Engr-in-Charge.
Make:- Bajaj Cat Part No BRTFG45 W or equivalent in Chrompton Greaves / Havells. | 25 | Each | 2,929 ₹73,225 | 2,953 ₹73,825 | 3,000 ₹75,000 | 2,800 ₹70,000 | 3,100 ₹77,500 | 3,131 ₹78,275 | 2,780 ₹69,500 Lowest | 2,933 ₹73,325 |
| 6.00 | Supply and fixing Pressure die cast aluminium housing LED street light luminaires with IP66 of 90 Watts, complete all as specified and directed by Engr-in-Charge.
Make Bajaj Cat Part No BRTFG90 W or equivalent in Chrompton Greaves / Havells. | 20 | Each | 7,469 ₹1,49,380 | 7,500 ₹1,50,000 | 7,530 ₹1,50,600 | 7,200 ₹1,44,000 Lowest | 7,700 ₹1,54,000 | 7,663 ₹1,53,260 | 7,400 ₹1,48,000 | 7,417 ₹1,48,340 |
| 7.00 | S&F of pressure die cast aluminium housing LED street light luminaires with IP66 of 120 Watts, complete all as specified and directed by Engr-in-Charge.
Make Bajaj Cat Part No BRTFG120 W LED I or equivalent inChrompton Greaves / Havells. | 15 | Each | 10,669 ₹1,60,035 | 8,977 ₹1,34,655 Lowest | 9,321 ₹1,39,815 | 9,220 ₹1,38,300 | 10,200 ₹1,53,000 | 12,077 ₹1,81,155 | 10,190 ₹1,52,850 | 11,000 ₹1,65,000 |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
27 Jun 2026, 6:00 pmClosed
GE NW KARANJA
NAVAL STATION KARANJA, URAN, RAIGAD, MAHARASHTRA
REPAIR REPLACEMENT AND IMPROVEMENT OF EXISTING LT PANEL SUB PANEL CONTROL CABLES DBS MCCBS MCBS CONTACTOR TIMER VOLTMETER AMMETER ARMOURED CABLE AND EARTHINGS WITH CONNECTED ACCESSORIES AND ALLIED WORKS OF E/M-II AC PLANT INSTALLATION UN
2026_MES_769989_1
8333/E8
Open Tender
Civil Works
Item Rate
270 days
GE NW KARANJA
Class D and above and category b (i)
8 documents required · 8 mandatory
₹500
Yes
GE NW KARANJA
₹98,000
Yes
13 Aug 2026
5 Jun 2026
29 Jun 2026
5 Jun 2026
27 Jun 2026
20 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply, installation, commissioning and testing of factory made, CPRI type tested, indoor, cubical compartmental type HVAC Panel in replacement of HVAC Panel DBM 16 AC plant suitable size, having both sides openable with hinged double doors & locking arrangement and IP 42 protection made out of 2.0 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labeling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel sheet, vitreous enameled (white) with letters figures and conventional skull and bones in signal red colour, suitable for 3- Phase 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length & size, including fixing lugs, bolts, screws etc. complete with accessories as and as directed by Engineer-in-charge, Make: CPRI approved panel builder. The HVAC Panel shall comprising of the following provisions:-
Bus bar Chamber:
INCOMER:-
[i] 01 Set (3L + N) of copper bus bar of rated capacity 320 Amp, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connection Incoming:[ii] 250 A, 415 V, Ics = 100% Icu = 26 kA, 50 Hz FP MCCB, conforming to IEC 60947-2, having thermal magnetic based trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (Ready, Overload and pre-alarm & Overload), etc.- 01 Nos.
[ii] Cl 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Run hrs. On hrs & interupts01 Nos.
[iii] LED phase indicators (Red, Yellow, Blue) - 01 Set
Outgoing:
[i] 100 A, 415 V, Ics = Icu = 16 kA, conforming to IEC 60947- 2, 50 Hz, FP MCCB with adjustable thermal settings & fixed magnetic settings with compression lug connectors and thermal magnetic trip unit (TMD)- 03 Nos. [for chillers] | 1 | Each Job | - | - |
| 1.01 | BoQ Serial Item No.1.00 Contd -
[ii] 63 A, 415 V, Ics = Icu = 16 kA, conforming to IEC 60947- 2, 50 Hz, FP MCCB with adjustable thermal settings (0.70- 1 X In) & fixed magnetic settings with compression lug connectors and thermal magnetic trip unit (TMD)- 01 Nos. [for AHU]
[iii] 25 A, 415 V, Ics = Icu = 16 kA, conforming to IEC 60947- 2, 50 Hz, FP MCCB with adjustable thermal settings & fixed magnetic settings with compression lug connectors and thermal magnetic trip unit (TMD)- 02 Nos. [for condenser pump]
(iv) 20 A, 415 V, Ics = Icu = 16 kA, conforming to IEC 60947- 2, 50 Hz, FP MCCB with adjustable thermal settings & fixed magnetic settings with compression lug connectors and thermal magnetic trip unit (TMD)- 03 Nos. [for Cooling tower & 02 Spare]
(v) Fully automatic DOL starter, complete with contactors, push button, LED type indicators, auto/manual selector switch, overload protection, current sensing type single phase preventer complete with all accessories and wiring etc-total 01 Nos. (Cooling tower motor capacity 3 HP - 01 Nos)
(vi) Fully automatic Star Delta Starter, complete with contactors, push button, LED type indicators, auto/manual selector switch, overload protection, current sensing type single phase preventer complete with all accessories and wiring etc-total 02 Nos (condenser pump capacity 5 HP - 02 No)
[vii] LED phase indicators (Red, Yellow, Blue)- 8 Set , [viii] Cl 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Run hrs. On hrs & interupts10 Nos. | - | - | - | - |
| - | Supply, installation, commissioning and testing of factory made, CPRI type tested, indoor, cubical compartmental type HVAC Panel in replacement of HVAC Panel DBM 17 AC plant suitable size, having both sides openable with hinged double doors & locking arrangement and IP 42 protection made out of 2.0 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labeling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel sheet, vitreous enameled (white) with letters figures and conventional skull and bones in signal red colour, suitable for 3- Phase 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length & size, including fixing lugs, bolts, screws etc. complete with accessories as and as directed by Engineer-in-charge, Make: CPRI approved panel builder. The HVAC Panel shall comprising of the following provisions:-
Bus bar Chamber:
INCOMER:- [i] 01 Set (3L + N) of copper bus bar of rated capacity 320 Amp, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connection Incoming:[ii] 250 A, 415 V, Ics = 100% Icu = 26 kA, 50 Hz FP MCCB, conforming to IEC 60947-2, having thermal magnetic based trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (Ready, Overload and pre-alarm & Overload), etc.- 01 Nos. [ii] Cl 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Run hrs. On hrs & interupts01 Nos. [iii] LED phase indicators (Red, Yellow, Blue) - 01 Set
Outgoing:
[i] 125 A, 415 V, Ics = Icu = 16 kA, conforming to IEC 60947- 2, 50 Hz, FP MCCB with adjustable thermal settings & fixed magnetic settings with compression lug connectors and thermal magnetic trip unit (TMD)- 02 Nos. [for chillers] | 1 | Each Job | - | - |
| 2.01 | BoQ Serial Item No.2.00 Contd -
[ii] 63 A, 415 V, Ics = Icu = 16 kA, conforming to IEC 60947- 2, 50 Hz, FP MCCB with adjustable thermal settings (0.70- 1 X In) & fixed magnetic settings with compression lug connectors and thermal magnetic trip unit (TMD)- 01 Nos. [for AHU]
[iii] 40 A, 415 V, Ics = Icu = 16 kA, conforming to IEC 60947- 2, 50 Hz, FP MCCB with adjustable thermal settings & fixed magnetic settings with compression lug connectors and thermal magnetic trip unit (TMD)- 02 Nos. [for condenser pump]
(iv) 20 A, 415 V, Ics = Icu = 16 kA, conforming to IEC 60947- 2, 50 Hz, FP MCCB with adjustable thermal settings & fixed magnetic settings with compression lug connectors and thermal magnetic trip unit (TMD)- 03 Nos. [for Cooling tower & 02 Spare]
(v) Fully automatic DOL starter, complete with contactors, push button, LED type indicators, auto/manual selector switch, overload protection, current sensing type single phase preventer complete with all accessories and wiring etc-total 01 Nos. (Cooling tower motor capacity 3 HP - 01 No.)
(vi) Fully automatic Star Delta Starter, complete with contactors, push button, LED type indicators, auto/manual selector switch, overload protection, current sensing type single phase preventer complete with all accessories and wiring etc-total 02 Nos. (condenser pump capacity 10 HP - 02 No)
[vii] LED phase indicators (Red, Yellow, Blue)- 8 Set
[viii] Cl 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Run hrs. On hrs & interrupts 8 Nos. | - | - | - | - |
| - | Supply, installation, commissioning and testing of factory made, CPRI type tested, indoor, cubical compartmental type HVAC Panel in replacement of HVAC Panel HTL 05 AC plant suitable size, having both sides openable with hinged double doors & locking arrangement and IP 42 protection made out of 2.0 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labeling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel sheet, vitreous enameled (white) with letters figures and conventional skull and bones in signal red colour, suitable for 3- Phase 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length & size, including fixing lugs, bolts, screws etc. complete with accessories as and as directed by Engineer-in-charge, Make: CPRI approved panel builder. The HVAC Panel shall comprising of the following provisions:- Bus bar Chamber:
INCOMER:-
[i] 01 Set (3L + N) of copper bus bar of rated capacity 320 Amp, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connection Incoming:[ii] 250 A, 415 V, Ics = 100% Icu = 26 kA, 50 Hz FP MCCB, conforming to IEC 60947-2, having thermal magnetic based trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (Ready, Overload and pre-alarm & Overload), etc.- 01 Nos.
[ii] Cl 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Run hrs. On hrs & interupts01 Nos.
[iii] LED phase indicators (Red, Yellow, Blue) - 01 Set
Outgoing:
[i] 100 A, 415 V, Ics = Icu = 16 kA, conforming to IEC 60947- 2, 50 Hz, FP MCCB with adjustable thermal settings & fixed magnetic settings with compression lug connectors and thermal magnetic trip unit (TMD)- 03 Nos. [for chillers] | 1 | Each Job | - | - |
| 3.01 | BoQ Serial Item No.3.00 Contd -
[ii] 63 A, 415 V, Ics = Icu = 16 kA, conforming to IEC 60947- 2, 50 Hz, FP MCCB with adjustable thermal settings (0.70- 1 X In) & fixed magnetic settings with compression lug connectors and thermal magnetic trip unit (TMD)- 01 Nos. [for AHU]
[iii] 25 A, 415 V, Ics = Icu = 16 kA, conforming to IEC 60947- 2, 50 Hz, FP MCCB with adjustable thermal settings & fixed magnetic settings with compression lug connectors and thermal magnetic trip unit (TMD)- 02 Nos. [for condenser pump]
(iv) 20 A, 415 V, Ics = Icu = 16 kA, conforming to IEC 60947- 2, 50 Hz, FP MCCB with adjustable thermal settings & fixed magnetic settings with compression lug connectors and thermal magnetic trip unit (TMD)- 03 Nos. [for Cooling tower & 02 Spare]
(v) Fully automatic DOL starter, complete with contactors, push button, LED type indicators, auto/manual selector switch, overload protection, current sensing type single phase preventer complete with all accessories and wiring etc-total 01 No. (Cooling tower motor capacity 3 HP - 01 No.)
(vi) Fully automatic Star Delta Starter, complete with contactors, push button, LED type indicators, auto/manual selector switch, overload protection, current sensing type single phase preventer complete with all accessories and wiring etc-total 02 Nos. (condenser pump capacity 5 HP - 02 No)
[vii] LED phase indicators (Red, Yellow, Blue)- 8 Set
[viii] Cl 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Run hrs. On hrs & interupts10 Nos. | - | - | - | - |
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.67 MB
8333TenderDocs.pdf
Tender Documents • 1.20 MB
BOQ_862271.xls
BOQ • 0.87 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .