| 1 | 1₹17.3 LAccepted-AOC | 1 | Accepted-AOC Being lowest | |
| 2 | 2₹19.8 L+₹63,180 (3.30%)Rejected-Finance | 2 | Rejected-Finance Not being lowest | |
| 3 | 3₹21.0 L+₹1.8 L (9.56%)Rejected-Finance 9 NAROTTAM KUNJ MADHU NAGAR AGRA CANTT 282001 | AGRA | UTTAR PRADESH | 282001 | 3 | Rejected-Finance Not being lowest |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
4 Sept 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
HQ CWE Agra
112 Taj Road, Agra Cantt
REPAIR / MAINT OF HT DISTRIBUTION SYSTEM AND OTHER ALLIED WORKS AT FATEHGARH CANTT
2024_MES_664601_1
86188/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
Fatehgarh
MES contractors enlisted for Class E and above and category b(ii) for unenlisted contractors meeting the enlistment criteria corresponding to value class and category of work
8 documents required · 8 mandatory
₹500
AGE (I) Fatehgarh
₹50,000
5 Dec 2024
8 Jul 2024
11 Sept 2024
8 Jul 2024
4 Sept 2024
22 Jul 2024
8 Jul 2024 - 15 Jul 2024
Amount
Excavation in trenches/ foundation in soft/ loose soil not exc. 1.5 metre wide and n'exc. 1.50m deep for HT under ground cable/pole foundation and getting out including forming bottom surface to required level or slope, complete all as specified and directed
Returning filling including spreading leveling watering and well ramming in layers not exc 25Cm in soft/ loose soil, complete all as specified and directed.
Removing excavated material in soft/ loose soil n'exc 50M and depositing where directed at a level n'exc1.5M above the starting point, complete all as specified and directed.
Dismantling cross-arms of mild steel channel or angle sections etc including mild steel bolts , nuts,washers etc complete all as specified and as directed
Dismantling of old unserviceable HT concrete/Steel pole of 11 Mtr long with necessary demolition of concrete foundation including excavation, earth work complete all as specified and as directed.
M&L for sand cushioning to U/G cable in layers of 23 cm thick ( 8 Cm before laying the cable and 15 Cm thick after laying the cable) in trenches complete all as specified and directed. Note :- Only Puned down volume shall be measured.
Supply and laying un-reinforced precast concrete cable cover, class HV, Type I, flat size 300 mm x 180 mm x 40 mm laid dry for protection of UG cable complete all as specified and directed
Dismantling / Taking out unserviceable HT cables for replacement of any size from any position i.e ground / walls / poles / culverts etc complete with protection pipe complete all as specified and directed . Note : Earth work shall be measured and paid separately
Supply, laying , jointing and testing of HT XLPE cable 3 core, 11000 volt screened, PVC 'E' grade insulated bedded, galvanised steel (Heavy duty) strip armoured with aluminium conductor 11 KV pressure earth system confirming to IS-7098(Part-I) 1977 and part-II of 1985 laid in pipe /ducts/trenches, under floor and road or fixedd to wall etc complete cross-sectional area of cable 95 sqmm 3 core, all as specified and directed.
M & L in replacement of GI tubing light grade for passing through cables under the floor ,along the wall or along the pole of 80 mm bore and fixed to the poles/walls with suitable size of MS clamps and nut and botls/washers etc including taking down old GI tubing complete all as specified and directed.
M&L Cross-arms, Bracings,channel or angle sections, Supports, Clamps and Back Plates fabricated from Structural Steel Sections including Nuts, Bolts, Washer, welding, bending cold or hot, drilling holes for Bolts, in any shape or size as indicated/ directed and inclusive of two coat of Aluminium Paint over a coat of red oxide primer, complete all as specified and as directed.
Material and labour for lightning arrester 11000 volts non linear resister type conforming to IS-3070 part-I, line discharge class-2, nominal discharge 10 KA and high discharge 65 KA assembly complete suitable for 11 KV including all clamps, nuts, bolts and washers and connecting to earth with 4 mm dia GI wire complete all as specified and directed.
M&L in replacement of indoor end terminal joints heat shrinkable Suitable for HT 11000V, XLPE insulated armoured Heavy duty under ground cable including joint kits and labour complete for making joints suitable for aluminium conductor cable of cross sectional area 120 Sqmm, 3 Core, complete all as specified and directed.
M&L in replacement of indoor end terminal joints heat shrinkable Suitable for HT 11000V (Earthed), XLPE insulated armoured Heavy duty under ground cable including joint kits and labour complete for making joints suitable for aluminium conductor cable of cross sectional area 95 Sqmm 3 Core complete all as specified and directed.
M&L in replacement of outdoor end terminal joints heat shrinkable Suitable for HT 11000V (Earthed), XLPE insulated armoured Heavy duty under ground cable including joint kits and labour complete for making joints suitable for aluminium conductor cable of cross sectional area 120 Sqmm 3 Core complete all as specified and directed.
M&L in replacement of outdoor end terminal joints heat shrinkable Suitable for HT 11000V (Earthed), XLPE insulated armoured Heavy duty under ground cable including joint kits and labour complete for making joints suitable for aluminium conductor cable of cross sectional area 95 Sqmm 3 Core complete all as specified and directed
M&L in replacement of straight through joints heat shrinkable Suitable for HT 11000V, XLPE insulated armoured Heavy duty under ground cable including joint kits and labour complete for making joints suitable for aluminium conductor cable of cross sectional area 120 Sqmm 3 Core complete all as specified and directed.
M&L in replacement of straight through joints heat shrinkable Suitable for HT 11000V, XLPE insulated armoured Heavy duty under ground cable including joint kits and labour complete for making joints suitable for aluminium conductor cable of cross sectional area 95 Sqmm 3 Core all as specified and directed.
Boring holes horizontally under road without damaging the surface of road ( minimum 1.0 Metre below the road surface with the help of GI tubing not exc 80 mm bore(dia) for passing UG cable, complete all as specified and as directed. Note : - GI Pipe laid will be measured and paid separately under appropriate item
Supply, installation, commissioning and testing of switch air break gang operated HT 11000 volts grade triple pole with 09 insulators, 200 amp capacity current rating complete with dropout fuse assembly with fuse carrier fuse elements mounted on insulators and steel frame mechanically operated mechanism from ground level consisting of rod of 25 mm nbore GI pipe, light grade of suitable length worked from ground level with locking arrangement fixed with flat iron clamp 50X6 mm and MS channel of suitable size & length for fixing GO/DO including bolts, nuts and washers complete all as specified and directed.
S&F steel tubular swaged pole type 410 SP 55 (11 mtr. Long) complete with cast iron base plate/final taper plug, bolt, nuts and washers including excavation earth work in any type of soil , PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in plinth block ,copping PCC 1:2:4 , including two coats of aluminium painting over a coat of red oxide primer on external surface and black bituminous paint on internal surface of pole and external surface upto planting depth as specified in SSR 2009 Part-I including writing pole numbers with white lettering on black background and making black & yellow strips upto 1.5 mtr height including excavation and earth work and PCC copping complete as specified and directed.
Dismantling and Taking out Transformer from its position from any location under AGE(I) Fatehgarh for repair/rewinding of capacity 100 to 500 KVA , 11/0.433 KV capacity disconnecting /opening HV, LV Electrical connections, earthing connections along with following other works. (a) Transporation of transformer to workshop at Unnao/Kanpur and back to site by making necessary arrangements of T&P (crane, recovery, vehicle, tripoid to be arranged by firm ) as directed (b) Opening of transformer top cover by extraction ,removing of serviceable - unserviceable nuts bolts and washers etc in presence of Engr -in -Charge. (d) Lifting primary coil (HT) and secondary coil (LT) , dismantaling of transformer complete part by part carefully , and display all the parts without damaging any portion for inspection of Engr -in -Charge. (e) Refilling topping up of new transformer oil after dehyderation and filteration in transformer. (f) Reassembeling the transformer complete with all existing serviceable parts, and new parts as ordered . (g) Reinstall the Transformer at site in position as directed after repair connecting HV, LV electrical connections, earthing connections and testing to entire satisfaction on load . Note- (a) Payment shall be made on actual weight basis i.e. actual weight of finished coil before varnishing and bakinge.(b) Renewal of adequate size Nut, bolts & washers of transformer top cover shall deemed to be included in UNIT RATE QUOATED
M & L for rewinding HT coil of 11/0.433 KV Transformer any capacity using proper size DPC copper wire and insulation material,heating coils in heat chamber after rewinding including taking out carefully burnt unserviceable copper winding of coils complete all as specified and directed.
M & L for rewinding LT coil of 11/0.433 KV Transformer any capacity using proper size DPC copper wire and insulation material,heating coils in heat chamber after rewinding including taking out carefully burnt unserviceable copper winding of coils complete all as specified and directed.
Dehydration and filtration of existing transformer oil of transformers capacity ranging from 100 KVA to 500 KVA ( 1/0.433 KV ) on site at different locationswithout disturbing the power supply system with filtration machine and heating systemin order to achieve Di-electri strength of oil 40 KV minimum 2.5 mm gap complete all as specified and as directed. Note : (a) Testing of transformer HT switch gear oil before & after dehydration shall be carried out as directed(b) The unit of payment under this term shall be per liter of oil meant for all process to the entire completion of jobs
Supply and filling up of Transformer oil conforming to as per IS:335-1993 in topping up/replacement up to desired level of transformer oil capacity complete all as specified and directed. ( Note : Dielectric strength of oil should not be less than 50 KV complete all as specified and directed.)
Supply and replacing silica gel in crystal form of breather assembly of transformer capacity upto 1500 KVA at installed site complete all as specified and directed.
Repair/servicing to transformer at site of capacity 100 to 500 KVA installed on plinth/pole mounted structur by opening top cover & replacing unserviceable spares/components of transformer ,without lifting core assembly reassembling after repair & testing complete all as specified and directed
Supply only ceramic Bush insulator on LT side as per existing size,shape and specification for capacity 100 to 500 KVA,11/0.433 KV transformer complete all as specified and directed
Supply only cork sheet gasket ( set of four) for ceramic bushing on LT side as per existing size,shape and specification for capacity 100 to 500 KVA ,11/0.433 KV transformer complete all as specified and directed
Supply only ceramic Bush insulator on HT side as per existing size,shape and specification for capacity 100 to 500 KVA ,11/0.433 KV transformer complete all as specified and directed
Supply only top cover gasket as per existing size,shape and specification for capacity 100 to 500 KVA ,11/0.433 KV transformer complete all as specified and directed
Supply only breather assembly as per existing size,shape and specification for capacity100 to 1500 KVA ,11/0.433 KV transformer complete all as specified and directed
M & L for preparing old painted surfaces by scrapping and removing old paints, rust etc from steel tubular poles ( above the planting depth and PCC coping of 11.0 Metre length pole ) and Mild Steel cross arms,cable protection pipe,brackets etc and applying one coat of synthetic enamel paint alternate yellow & black strips painting( 5 nos each strip 300 mm wide) and remaining portion of pole and cross arms,cable protection pipe,brackets etc treated with one coats of Aluminium paint incl writing pole no with white paint on black back ground complete all as specified and as directed
M & L for 2 Pole structure preparing old painted surfaces by scrapping and removing old paints, rust etc from steel tubular poles ( above the planting depth and PCC coping of 11.0 Metre length pole ) and Mild Steel cross arms,cable protection pipe,brackets etc and applying one coat of synthetic enamel paint alternate yellow & black strips painting (5 nos each strip 300 mm wide) and remaining portion of pole and cross arms,cable protection pipe,brackets etc treated with one coats of Aluminium paint incl writing pole no with white paint on black back ground complete all as specified and as directed
M & L for 4 Pole structure preparing old painted surfaces by scrapping and removing old paints, rust etc from steel tubular poles ( above the planting depth and PCC coping of 11.0 Metre length pole ) and Mild Steel cross arms,cable protection pipe,brackets etc and applying one coat of synthetic enamel paint alternate yellow & black strips painting (5 nos each strip 300 mm wide) and remaining portion of pole and cross arms,cable protection pipe,brackets etc treated with one coats of Aluminium paint incl writing pole no with white paint on black back ground complete all as specified and as directed
Dismantling of mechanism system of defecitive 11 KV VCBs/ OCBs, repair/replace the unserviceable items such as closing/triping coil, spring charging motor etc including overhauling the same after necessary cleaning with CTC, and providing silicon grease to the all moving parts including adjustment of all springs etc and made 100% serviceability complete all as specified and directed. NOTE :- Spring charging motor shall be measured and paid separately.
Supply only spring charging motor of 230 volts 0.25 HP, 8000 RPM of 11 KV VCB's type VE -12, 30/110 volts complete all as specified and directed.
Supply and fixing in replacement of 3 phase over current and earth fault (IDMT) relay installed on existing panel or separate enclosure, with connecting, internal control wiring , testing complete all as specified and directed NOTE Ser item No. 37 to 39:- (i) Tenderer shall be checked the existing VCB's/OCB's and shall be taken all the details of existing defective one before order the materials (ii) New items shall be match with the existing system in any cases. (iii) Any minor adjustment /modification for the fixing the item if required at site contractor shall be carried out at site without any extra cost.
M&L for earthing complete with galvanized steel earth plate electrode 600 x 600x 6 mm thick buried in ground vertically to a depth n.less than 2.25 mtr below normal ground level connected to galvanized steel strip 25 x 4 mm earth lead by means of bolts, nuts and washers made of galavanised iron or steel earth strip protected by 40 mm bore light grade GI pipe and connected for body earthing of feeder pillar box all as specified and directed incl PCC work as per sketch No 3 of SSR Part -I (2009) pit cover slab of size 300x300x50 mm with handle as shown in drawing funnel, wire mesh 20 mm dia GI pipe medium grade for watering, charcoal and slat in alternate layers incl necessary earth pole and excavation in hard/dense soil and removal etc incl testing complete all as specified and directed.
Trimming of tree branches girth not exceeding 50 mm around OH eiectric lines and cleaning up to 3.00 mtr from the OH electric lines and removing trimmed branches from sites and stacking as ordered complete all as specified and as directed.
Supply, installation, testing and commissioning of a set of 3 Nos lightening arrestors station class single pole non linear register type as per IS 3070 with all fittings discharge capacity 10 KA, rating 30KV(rms) suitable for 33 KV grounded neutral link system fixed on channels, cross arms including connecting to over head line and up to earth pit complete all as specified and directed.
virendera singh (BID ID -3074130)
M/s SCHOLASTIC ENTERPRISES (BID ID -3073053)
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .