Loading…
Loading…
Tender Value
₹9.0 Cr
EMD Value
₹4.5 L
Closing Date
28 May 2026, 5:00 pmClosed
MR Yognarayan sahu(DFLT)
CE(Raipur)
CONSTRUCTION OF OFFICE BUILDING FOR PWD DIVISION NO.3 & DIVISION OFFICE (E/M) BUILDING -02 NOS & 04 NOS SUB DIVISIONAL OFFICE BUILDING AT DISTT. RAIPUR.( DN. NO.3 NAWA RAIPUR).
190179
NIT No. 139/TC/EinC/PWD/26-27
RESTRICTED TENDER
WORKS
18 days
CE(Raipur)
Required Past Technical Experience: AS PER NIT
Required Financial Turnover (in INR): AS PER NIT
Required Bid Capacity (in INR): AS PER NIT
17 documents required · 17 mandatory
Public Works Department (PWD)
WORKS
MR Yognarayan sahu(DFLT)
RESTRICTED TENDER
PERCENTAGE
A B
CE(Raipur)
PWD Circle-1,Raipur
Pwd Div No3 Raipur
120
18
No
0
190179
28 May, 2026 5:00:00 PM IST
2 Jun, 2026 10:00:00 AM IST
6 May, 2026 5:00:00 PM IST
NIT No. 139/TC/EinC/PWD/26-27
CONSTRUCTION OF OFFICE BUILDING FOR PWD DIVISION NO.3 & DIVISION OFFICE (E/M) BUILDING -02 NOS & 04 NOS SUB DIVISIONAL OFFICE BUILDING AT DISTT. RAIPUR.( DN. NO.3 NAWA RAIPUR).
450000.00 INR
RTGS/CHALLAN (ONLINE) Internet Banking (ONLINE)
89990000.00
2
1 Jun, 2026 5:00:00 PM IST
89990000
AS PER NIT
AS PER NIT
AS PER NIT
0.00 INR
22d 16h 39m
17 documents required · 11 mandatory · 6 optional
₹0
₹4.5 L
4 May 2026
4 May 2026
2 Jun 2026
6 May 2026
28 May 2026
6 May 2026
1 Jun 2026
Surface dressing of the ground including removing vegetation and making up undulations and in-equalities not exceeding 15 cms in depth/ height including disposal of rubbish up to 1.5 m lift and lead up to 50m (at least 5m away from the dressed area).
Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunks and branches removing the roots and stacking of serviceable material after cutting in approved sizes and disposal of unserviceable material. 1.3.2) Beyond 60 cm girth upto and including 120 cm girth
Beyond 120 cm girth upto and including 240 cm girth
Excavation for all types and sizes of foundations, trenches and drains or for any other purpose including disposal of excavated stuff up to 1.5 m lift and lead up to 50m (at least 5m away from the excavated area), including dressing and levelling of pits. 1.1.1) In all types of soil
Extra for every additional lift of 1.5 m or part thereof. 1.6.1) All types of soil
Pumping out water caused by springs tidal or river seepage, broken water main or drains and like during Excavation or during Excavation and laying of base concrete (volume to be calculated taking height from water level to bottom of pit and to be measured and paid) .
Filling from available excavated stuff (Excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering with a lead up to 50 M. and lift up to 1.5 M.
Providing and filling in plinth with sand/ Crusher dust and hard moorum under floor in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering, including dressing etc. complete.
Supplying chlorpyrifos/ Lindane emulsifiable concentrate of 20% in sealed containers including delivery as specified.
Diluting chemical emulsion (chlorpyrifos/ lindane) in water as per manufacturers recommendation and injecting for pre-constructional curative cum preventive anti-termite treatment:(Five year service guarantee bond to be signed by contractor) 1.25.1) Surface treatment by spreading emulsion under floor, over the plinth area before laying base concrete @ 5 litres / sqm
Carriage by mechanical transport up to 5 km lead: 1.26.1) Earth
Dismantled Building debris (Mulba)
Extra for mechanical transport for every one km or part thereof beyond first 5 km lead. 1.27.1) Earth
Providing and fixing formwork including centering, shuttering, strutting, staging, propping bracing etc. complete and including its removal at all levels, for: 2.1.1) Foundations, footings, base of columns and plinth beam in any shape and size.
Wall of any thickness including attached pilasters, buttresses etc. in super structure.
Window sills, anchor blocks, string course, bends, copings, bed plates and like.
Columns, Pillars, Piers and likes- rectangular or square in shape
Suspended floors, roofs, access platform, balconies (plain surfaces) and shelves (cast in situ)
Beams, lintels, cantilevers & walls
Weather shade, chhajja, Cornices and mouldings
Stair cases of all types excluding spiral and folded plate type, including risers and landings
Extra for additional height every 1m or part thereof where height of staging for form work exceeds 4.0 metre with adequate bracing, propping etc at all levels, for suspended floor, roof, landing, beam and balcony. (only plan area is to be measured):
Providing and laying nominal mix plain cement concrete with crushed stone aggregate using concrete mixer in all works up to plinth level excluding cost of form work. 3.1.3) 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size).
1:4:8 (1 cement : 4 coarse sand 8 graded stone aggregate 40mm nominal size).
Providing and laying nominal mix reinforced cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work. (Note :Excess/ less cement used as per design mix is payable/ recoverable separately) 3.2.1) 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20mm nominal size).
Providing and laying design mix reinforced cement concrete with crushed graded stone aggregate 20mm nominal size using batching plant, transit mixer and concrete pump, in all works up to plinth level excluding cost of form work. 3.3.3) M-30 Grade
Extra for laying PCC/RCC of any grade in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth:
Extra for laying PCC/RCC of any grade in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth:
Extra for laying PCC/RCC of any grade in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth:
Extra for laying PCC/RCC of any grade in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth:
Providing and placing in position reinforcement for R.C.C. work including straightening, cutting, bending, binding etc. complete as per drawings including cost of binding wire in foundation and plinth all complete: 3.12.2) Thermo-Mechanically treated bars FE 500D
Providing and laying damp proof course (up to 50mm thick) with plain cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded crushed stone aggregate 20mm nominal size) including form work.
Providing and mixing water proofing material in PCC/ RCC work in the proportion recommended by the manufacturer.
Providing and fixing aluminium strip 1.60 mm thick on expansion joints with iron screws as per design to match the colour, shade of wall treatment .
Providing and fixing in expansion joint pre moulded cross linked polymer based filler as per IS:1838 (part III) of approved make including cutting to required size and shape etc complete. 3.23.1) 50 mm thick
Providing and applying for hermetically water proof sealing of vertical / horizontal expansion joint with approved make Poly Sulphide Sealant compound (two component elastomeric sealant) having 80% tensile modulus elongation, proper bonding with building surface complete with cleaning and preparing of building surface, applying polymer solvent primer, providing and fixing PU back up rod of suitable dia in expansion joint for core making, filling with Poly Sulphide Sealant (Sealant filling depth should be minimum half of the joint gap), finishing and smoothing the surface etc complete. The application shall be got done through the authorised applicator of the manufacture of compound 3.24.1) For gap 50 mm wide
Providing and laying integral cement based treatment for water proofing on horizontal surface at all depth below ground level for underground structures using rough Kota stone and consisting of: i) 1st layer of 22mm to 25mm thick approved rough Kota stone slab over a 25mm thick base of cement mortar 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound conforming to IS:2645 over the leveling course (leveling course to be paid separately). Joints sealed and grouted with cement slurry mixed with water proofing compound. ii) 2nd layer of 25mm thick cement mortar 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound. iii) Finishing top with stone aggregate of 10mm to 12mm nominal size spreading @ 8 cudm/sqm thoroughly embedded in the 2nd layer.
Providing and laying integral cement based treatment for water proofing on the vertical surface at all levels by fixing 22 mm to 25mm thick rough Kota stone slab with cement slurry mixed with water proofing compound conforming to IS:2645 with a gap of 20mm (minimum) between stone slabs and the receiving surfaces and filling the gaps with neat cement slurry mixed with water proofing compound and finishing the exterior of stone slab with 20mm thick cement mortar 1:3 (1 cement : 3 coarse sand) with neat cement punning mixed with water proofing compound complete.
Providing and laying water proofing treatment in sunken portion of WCs, bathroom, kitchen etc., by applying cement slurry mixed with water proofing cement compound consisting of following applications including surface preparation: i) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours.ii) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound@ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
Providing and laying three course damp proofing treatment in water reservoir, sump, tank etc., with bitumen felt and blown type petroleum bitumen at the rate of 1.6 Kg/sqm 1st, 3rd course and 2nd course with tar felt including applying priming coat at the rate of 0.25 litre per sqm and fillets and rounding corners, wherever required, complete. 4.10.1) Bitumen felt of type 2 grade 2 (Fibre base)
Providing water proofing treatment against dampness & Seepage on RCC or lime concrete roof/ terrace, over head tank, sunken slab consisting of following operations: i) Removing loose material and 25 mm cement concrete/ cement plaster including gola etc. and cleaning the surface. ii) Drilling 20mm dia holes spacing not more than 300 mm centre to centre in cracks and joint of wall & slab. iii) Injecting polymer based high strength water proofing compound of approved brand & make, admixed with cement in the ratio as specified by manufacturer, in holes by pressure pump. iv) Levelling the surface by providing and laying 25mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5/6mm) mixed with polymer based high strength water proofing compound of approved brand & make in the ratio as specified by manufacturer. v) Providing and laying of bonding slurry prepared by mixing of cement with approved make and brand acrylic polymer (as per IS 13435 Part-3) in two layers (totalling up-to 3mm thick) by brush. Second layer to be laid after 4 hours of first layer. vi) Providing and laying 15mm thick cement plaster in cement mortar 1:4 (1 cement : 4 coarse sand) and finishing the surface with neat cement admixed with integral water proofing compound (IS: 2645) as per manufacturers recommendations. This operation shall be continued up to 300 height on parapet wall. vii) After a short period of above operation a string marking shall be done making squares of 300x300mm.
Grading roof for water proofing treatment with: 4.13.1) Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10mm and down grade) including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design :
Brick work with modular well burnt clay bricks of crushing strength not less than 25 kg/sqcm and water absorption not more than 20% in foundation and plinth in: 7.2.2) Cement Mortar 1:6 (1 Cement : 6 Coarse Sand)
Brick work with modular fly-ash lime bricks (FaLG Bricks) confirming to IS:12894-2002 of class designation 4.0 in foundation and plinth in: 7.5.4) Cement Mortar 1:6 (1 cement : 6 coarse sand)
Extra for brick work in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth:
Extra for brick work in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth:
Extra for brick work in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth:
Half brick thick brick masonry with fly-ash lime bricks (FaLG Bricks) confirming to IS:12894-2002 of class designation 4.0 in superstructure above plinth level up to plinth level: 7.11.2) Cement Mortar 1:4 (1 cement : 4 coarse sand)
Extra for half brick work in superstructure above plinth level for every story or part thereof in addition to rate for up to plinth level:
Extra for half brick work in superstructure above plinth level for every story or part thereof in addition to rate for up to plinth level:
Extra for half brick work in superstructure above plinth level for every story or part thereof in addition to rate for up to plinth level:
Extra for providing and placing in position hopping 25x1.60 mm or 2 Nos 6mm dia MS bars reinforcement at every third course of half brick masonry.
Providing wood work in frames of doors, windows, clerestory windows and other frames wrought framed and fixed in position. 8.1.2) Sal, bijasal, benteak, khair, haldu
Providing 40x5mm iron hold fast 40cm long including fixing to frame with 10mm bolts nuts and wooden plug and embedding in Cement Concrete 1:2:4 in blocks of size 30x10x15cm
Providing and fixing flush door shutters, conforming to IS : 2202 (Part-I), decorative type core of block board construction with frame of first class hard wood and well matched teak ply veneering with vertical grains or cross bands and face veneers on both faces of shutters excluding hinges. 8.12.1) 40 mm. thick (single leaf)
35 mm. thick (single leaf)
Extra for double leaf shutter instead of single leaf.
Providing and fixing lipping with second class teak wood lipping on all edges of shutters. 8.18.4) 40 x 6 mm size
Providing and fixing 200 mm wide teak wood moulding such as base moulding, chair rail, architrave, moulded posts moulding skirting including necessary screws and painting on unexposed surfaces with wood primer etc complete for per cm thick.
Providing and fixing antique/ SS finished brass butt hinges with antique/ SS polished MS screw complete: 8.77.1) 125x85x5.50mm (Heavy Type)
Providing and fixing antique/ SS finished brass sliding door bolt with necessary bolts, nuts and antique/ SS polished MS screw complete: 8.79.1) 300X16mm
Providing and fixing antique/ SS finished brass door latch with antique/ SS polished MS screw complete: 8.80.1) 250x16x5mm
Providing and fixing antique/ SS finished brass tower bolts (Barrel type) with antique/ SS polished MS screw complete: 8.81.1) 250 x10 mm
Providing and fixing antique/ SS finished brass handles with antique/ SS polished MS screw complete: 8.84.1) 125 mm
Providing and fixing antique/ SS finished brass hanging door stopper with necessary antique/ SS finished MS steel screws complete.
Providing and fixing stainless steel butt hinges IS : 12817 marked with necessary stainless steel screws etc complete. 8.132.2) 125x2.5mm (heavy)
Providing and fixing stainless steel sliding door bolts with 16mm rod, 2.5mm thick flap, necessary stainless steel nuts bolts and screws etc complete. 8.137.1) 300 mm
Providing and fixing stainless steel door latch with 12mm rod, 2.5mm thick flap, necessary stainless steel screws etc complete. 8.138.2) 250mm
Providing and fixing stainless steel tower bolts (Barrel type) with necessary stainless steel screws etc complete. 8.139.3) 150 x10mm
Providing and fixing stainless steel door handles having flap thickness 2.5mm, necessary stainless steel screws etc complete. 8.140.1) 150 mm
Providing and fixing 30mm thick fibreglass reinforced plastic (F.R.P.) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF) / Polystyrene foam to be used as filler material throughout the hollow panel, casted monolithically with testing parameters of F.R.P. laminate conforming to table - 3 of IS: 14856 : 2000, complete.
Providing and fixing IS: 3564 marked aluminium die cast body tubular type universal hydraulic door closer with necessary accessories and screws etc complete.
Providing and fixing factory made UPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of UPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60±0.2 mm thick galvanised mild steel section made from roll forming process of required length (shape and size according to UPVC profile ), appropriate dimension of UPVC extruded glazing beads and UPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers(weight bearing capacity to be 40 kg), G.I fasteners 100*8mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame and sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and approved quality, all complete as per approved drawing and direction of Engineer - in -charge. (Single/double glass panes, wire mesh and silicon sealent shall be paid seperately vide chapter no. 9.51, 9.58, 9.59 Respectively. Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. 8.165 D2Three track three panels sliding window with fly proof SS wire mesh (Two nos. glazed & one wire mesh panels ) made of (small series ) frame 92 x 44 mm & sash 32 x 60 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension (Area of window up to 1.75 sqm).
Three track three panels sliding window with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm).
Providing and fixing zinc alloyed (white powder coated) touch lock for uPVC sliding window with necessary screws etc. complete.
Providing and fixing steel roller for uPVC sliding window with necessary screws etc. complete.
Providing and fixing steel (white power coated) crescent lock for uPVC sliding window/ door with necessary screws etc. Complete.
Structural steel work in single section including cutting, hoisting, fixing in position and applying a priming coat of red oxide zinc chromate primer.
Structural steel work riveted or bolted or welded in built-up sections, trusses and frames work upto a height of 5m above plinth level, including cutting, hoisting, fixing in position and applying a priming coat of red oxide zinc chromate primer.
Providing and fixing M.S. grill of approved pattern made of M.S. flats or square or round bars welded to steel frame of windows etc. including applying a priming coat of red oxide zinc chromate primer
Providing and fixing aluminium work for doors, windows, ventilators and partitions made out of extruded aluminium standard sections (main section with minimum 1.5mm thickness) conforming to IS: 733, IS: 1285 mitred and jointed mechanically including aluminium cleats, neoprene weather stripping gasket bevelled edge beading, screws duly fixed in wall/ floor with fixing clips or hold fasteners or bolts and nuts as required aluminium sections shall be anodized transparent or dyed to approved shade according to IS: 1868, minimum anodic coating shall be of grade AC-15. (Glazing to be paid for separately: 9.47.1) For fixed portion
For shutter of doors, windows & ventilators including providing and making provision for fixing of fitting wherever required including the cost of PVC/ neoprene gasket required (Fittings shall be paid for separately).
Extra for powder coated (minimum 50 micron) aluminium sections instead of anodized.
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC/ neoprene gasket etc. complete. (Cost of aluminium snap beading shall be paid in basic item):9.51.6With float Toughened glass panes of 5 mm thickness
Providing stainless steel railing/ grill made of S.S. flats, hollow S.S. pipe or square/ rectangular sections of approved design fixing in stair case, balcony or other places with metal fasteners and stainless steel bolts etc complete. 9.57.2) SS Grade 304
Extra for providing and fixing reflective glass panes in aluminium door, window, ventilator shutters and partitions instead of float glass. 9.59.2) 5 mm thickness
Designing, providing and fixing aluminium frame work made of special aluminium section on building face with M.S. angle iron brackets fixed on RCC structure with S.S. hold fasteners, including providing and fixing two sided structural adhesive tape of appropriate grade (NORTON or equivalent), on aluminium sections for fixing aluminium/ glass panel, sealing on periphery of frame work, by providing EPDM gasket, silicon weather sealant between aluminium frame and building structure including hire charges of double scaffolding complete.
Providing and fixing aluminium composite panels in approved panel sizes, thickness and shape on aluminium frame work on face of building. (Frame to be paid separately) 9.61.2) 4mm thick
Providing and fixing laminated glass sheet of 8.76mm thickness in approved sizes on aluminium frame work on face of building. (Frame to be paid for separately).
Providing and fixing clear float toughened glass door or partition in required thickness frameless in appropriated sizes inclusive of edge moulding police and making required size slot or hole for patch fitting/hardware etc. The glass to be assembled together with patch fitting and hardware in proper alignment with all labour tools and tackles etc. complete. (Patch Fittings and hardware to be paid for separately). 9.63.1) 12mm thick for door/partition
Providing and fixing of stainless steel grade 316 patch fitting and hardware of approved (Hardwyn, Ozone, Godrej) make in frame less toughened glass door or partition in proper alignment with all tools tackles and labour etc complete. 9.64.1) Top patch with pivot SS grade 304
Bottom lock patch with three key SS grade 304
Two way action Hydraulic floor spring machine heavy duty double cylinder type Capacity 120/150 kg mounted on floor including required cutting on floor and proper grouting with rich cement mortar.
H type handle 32x600mm SS 304 grade
Floor/Wall to Glass Connector SS grade 304
Supply and fixing of polymer precoated galvalume profile sheets (PPGL) of approved size, shape and pitch of corrugation, total coated thickness (TCT) 0.60 mm +/- 5%, epoxy primer on both side of the sheet and colour polyester top coat 18-20 microns and 6-7 microns on bottom. Sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55mm) with EPDM seal or with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead complete upto any pitch in horizontal/ vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Providing and fixing semi transparent polycarbonate compact sheet roofing of approved colour to make any normal shape of roofing / covering of any pitch and fixing with specially designed powder coated aluminium section with 60mm wide flange of standard design weighing not less than 1.1 kg/ m at spacing not more than 1.2 m centre to centre with EPDM gasket and silicon sealant on all four edges of aluminium section fixed with self drilling stainless steel screws all complete including aluminium edge angle 40 mm x 40 mm x3mm as per manufacture specification and as per direction of Engineer-in-Charge. 10.28.1) 6 mm thick twin wall
Providing and fixing at all height false ceiling consisting of frame work "W" / "U" / "L" sections made of G.I. sheet with zinc coating of grade 120 consisting of angle cleats of size 25mm wide x 1.6mm thick with flanges of 22mm and 37mm at 1200mm centre to centre one flange fixed to the ceiling with dash fastener 12.5mm diax40mm long with 6mm dia bolts to the angle hangers of 25x25x0.55mm of required length, and other end of angle hanger being fixed with nut and bolts to G.I. channels 45x15x0.9mm running at the rate of 1200mm centre to centre to which the ceiling section 0.5mm thick button wedge of 80mm with tapered flanges of 26mm each having clips of 10.5mm at 450mm centre to centre shall be fixed in a direction perpendicular to G.I. channel with connecting clips made out of 2.64mm diax230mm long G.I. wire at every junction including fixing the gypsum board with ceiling section and perimeter channels 0.55mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450mm centre to centre with 25mm long drive-all screws @ 230mm interval including jointing and fixing to a flush finish of tapered and square edges of the board with recommended filler, jointing tapes, finisher and two coats of primer suitable for board as per manufactures specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed including providing and fixing 12.5 mm thick tapered edge gypsum board conforming to IS: 2095- Part-I all complete as per drawing and specification and direction of the Engineer in Charge but excluding the cost of painting.
Providing and making 6mm thick cement plaster of mix: 11.1.1) In Cement mortar 1:3 (1 cement : 3 fine sand)
Providing and making 12mm thick cement plaster of mix: 11.2.4) In Cement Mortar 1:6 (1 cement : 6 fine sand)
Providing and making 15mm thick cement plaster on the rough side of single or half brick wall of mix: 11.3.4) In Cement Mortar 1:6 (1 cement : 6 fine sand)
Neat Cement punning.
Providing and making 18mm thick cement plaster in two coats with under layer of 12mm thick plaster 1:5 (1 cement : 5 fine sand) and top layer of 6mm thick with cement plaster 1:3 (1 cement : 3 fine sand) finished rough with sponge.
Extra for plastering of exterior walls when height exceeds 10m above ground level for every additional height of 3.0m or part thereof.
Extra for plastering done on mouldings, cornices or architraves including neat finish to line and level.
Providing and making 12mm thick plain cement mortar bands in cement mortar 1:4 (1 cement : 4 fine sand) per cm width: 11.31.2) Sunk Bands
Extra for plastering done on mouldings, cornices or architraves including neat finish to line and level. 11.32.2) Sunk Bands
Providing and fixing chicken mesh weighting not less than 250 gms/ sqm as per IS : specification in the required width with 40mm long steel nails on vertical and horizontal surface near R.C.C. and brick walls junctions including scaffolding and all lead and lifts etc. complete before plastering up to 10mts in height.
Cement concrete flooring with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm) finished with a floating coat of neat cement. 12.3.2) 50 mm thick
15 mm thick Table rubbed polished Granite stone slab flooring laid over 20mm (Average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry including rubbing and polishing etc. complete. (Area of slab should be 0.50 sqm and above) 12.45.1) Granite stone grey/pink
Granite stone black
15 mm thick Table rubbed polished Granite stone slab in risers and treads of steps skirting dado and pillars laid on 12mm (Average) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) and jointed with grey cement slurry including rubbing and polishing etc. complete (single stone is to be used for risers and treads of steps and width of stone for skirting and dado shall be equal to the height of skirting & dado and length of 1.0 m). 12.46.1) Granite stone grey/pink
25 mm thick KOTA stone slab flooring over 20mm (Average) thick base of cement mortar 1:4 laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including grinding rubbing and polishing etc. complete (Area of slab to be over 0.20 sqm and upto 0.50 sqm)
Providing and fixing rectified glazed ceramic Floor tiles of 1st quality conforming to IS : 15622-2017 of approved make, in all colours shades over 20mm thick bed of cement Mortar 1:3 (1 cement :3 coarse sand) and jointing with grey cement slurry @ 3.3Kg per sqm including pointing in white cement mixed with matching pigment complete. 12.74.1) Size 300x300mm thickness 7 to 8mm
Providing and fixing rectified glazed ceramic wall/dado tiles of 1st quality conforming to IS:15622-2017 of approved make, in all colours, shades on wall and dados over 12mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with matching pigment complete. 12.75.1) Size 300x450mm thickness 7 to 8 mm
Providing and laying DOUBLE/MULTI CHARGE (minimum 2.0 mm thick layer) VITRIFIED floor tiles with wate absorption less than 0.05% and conforming to IS:15622-2017 of 1st quality of approved make in all colours and shades and size mentioned below (+/- 10mm) laid on 20mm thick cement mortar 1:4 (1cement: 4 coarse sand) including grouting the joints with withe cement and matching pigments etc. complete. 12.79.1) Size 600x600mm thickness 9 to 10 mm
Providing and fixing plain cement concrete fibre reinforced heavy duty designer glazed floor tiles with uniform colour (for coloured tiles) and texture conforming to IS: 1237 (for abrasion wear) and IS : 516 (for compressive strength) of approved make, colours, shades and size on cement Mortar bed and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with matching pigment complete. 12.8.2) On floor, steps and risers over 20mm thick bed of cement Mortar 1:4 (1 cement : 4 coarse sand)
Providing and laying tactile full body vitrified tile (for vision impaired persons as per standard laid down in CPWD guide lines) of size having 300x300 and total thickness 15mm, water absorption less than 0.05% and conforming to I.S. 15622-2017 of H&R Johnson or equivalent approved make in all standard colour laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with white cement and matching pigments 12.80.1) Dot pattern hazard warning tactile 23 mm dia 36 dots (6 dot in both direction) and 5mm exposed from the surface
Strip pattern directional tactile 23 mm strip 4nos equally spaced and 5mm exposed to the surface
15mm thick Granite work (machine cut, table rubbed & mirror polished) for wall lining (veneer work) in cement mortar 1:3 (1 cement : 3 coarse sand) including pointing with cement mortar 1:2 (1 white cement: 2 marble dust) mixed with matching pigment. (Area of slab should be over 0.5 sqm). 13.4.2) Granite stone black
15mm thick Granite work (machine cut, table rubbed & mirror polished) for kitchen platform, vanity counters, window sills and similar locations of required size laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) including joints treated with white cement mixed with matching pigment including rubbing and polishing to edge moulding to give high gloss finish. 13.6.2) Granite stone black
Extra for providing edge moulding to 15mm thick stone counters, vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. 13.19.2) Granite work
Providing and applying French sprit polish on new wood work after preparing the surface by rubbing down smooth with sand papers, covering the knots, if visible, applying a coat of wood filler, cleaning the surface, applying various (minimum 4 coats ) of French Spirit polish @0.35 Lit/sqmt till the surface gives high gloss. Inclusive of Providing abro tape on edges and article and cleaning of adjucent surface with all tools,tackles and labours etc complete for the work.
Providing and applying 2mm thick white cement based polymeric Exterior grade Putty with minimum 3 coats applied @ 5.4 kg/ 10Sqm as per relevant IS code 17545:2021 (Product such as Birla wall care, Asian trucare,JK wall putty, Berger Bison wall putty) to make the surface smooth and even with all tools tackles and labour etc. complete for the work.
Providing and applying 2mm thick white cement based Acrylic grade putty with minimum 3 coats applied @ 4.0 kg/ 10Sqm as per relevant IS code 17545:2021 (Product such as Asian trucare, Berger Happy walls Putty , Birla Opus One pro smooth) to make the surface smooth and even with all tools tackles and labour etc. complete for the work . (This Item to be use in heigher grade painting works Item No. 14.65)
Providing and applying Polymaric cement primer on all surface applied @ 0.80 litrs/10 sqm as per relevant I.S. code 15489:1974 (product such as Birla white primacoat/activcoat, Asian Trucare , Dulux interior cement primer, Opus Calista / I10 ) with all tool tackles and labour etc. complete for the work .
Providing and applying of Acrylic primer on all surface applied @ 0.80 litrs/10 sqm as per relevant I.S. code 15489:1974 ( Product such as Asian Spark/suprimo , J.K. Primer, Dulux Acrylic Primer) with all tools tackles and labour etc. complete for the work.
Providing and applying Luxury plastic emulsion paint with roller application minimum three coats applied @ 1.25 lit / 10Sqm up to final finish as per relevant Type -1 Class D , C , B & A (Glossy /Semi Glossy and Matt , Egg Shell or Satin finish ) of required shade (Product such as Asian Royale Shyne,Dulux Velvet Touch, Berger Silk Luxury Emulsion ,Nippon Impression Pearl , Opus Pure Elegance) inclusive of providing abro tape on edges and article and cleaning of door, windows, floor and surface as required with all tools tackles and labour etc, complete for the work. (with 4 Years Warranty )
Providing and applying exterior surface with PREMIUM HEAVY DUTY Glossy or Matt Finish Exterior Emulsion paint of required shade to give protective and water proof finish minimum three coats applied @ 1.43 lit / 10Sqm up to final finish as per relevant I.S. Code 15489:2013 Type -2 Class D , C , B & A ( Glossy / matt / Egg Shell finish )having high DFT and silicon aditive for elastomaric property (Product such as Asian Ultima ,Dulux Weathershield Maxx , Berger Weathercoat All Guard , Nerolac Excel Total , Nippon Durafresh Expert , Opus Tru Look) inclusive of providing abro tape on edges and article and cleaning of door, windows, floor and surface as required with all tools tackles and labour etc. complete for the work. (With 4 Year Warranty)
Providing and applying acrylic modified resin EXTERIOR TEXTURED with special quality silica quartz plaster as an intermediate coating on external surface giving protective layer and decorative finish on plastered surface in approved design and shade (product such as Asian Apex Series Duracast Dulux weathersheald sandtax creation) as per manufacturer's specifications inclusive of providing abro tape on edges and article and cleaning of door, windows, floor and surface as required with all tools tackles and labour etc.complete for the work.14.70.12.0mm thickness (average) having design scratched with leveled & smooth surface.
Providing and applying satin/ matt finish Enamel paint mimimum 2 coats in all surface applying @ 0.75 lit/ 10 Sqm up to required finish as per relevent I.S. code 2932: 2013 of (Product such as Asian satin Enamel, Dulux Promise Premium Enamel, Nerolac Synthatic Enamel, Opus Prime enamel) inclusive of providing abro tape on edges and article and cleaning of door, windows, floor and surface as required with all tools tackle and labour etc. complete for the work.
Providing and applying priming coat on steel work with red oxide/ zinc phosphate primer applied @ 0.50 lit /Sqm as per relevant code 3536:1999 ( product such as Asian Zinc phosphate , Dulux Steel primer,Burger Red oxide primer ) with all tools tackles and labour etc. complete for the work.
Extra for painting exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof for all painting work with all tools , tackles and labour etc.complete for the work.
Excavation in Soil (by Mechanical Means.) Excavation for roadway in soil using mechanical means including loading in tipper for carrying of cut earth to embankment site and unloading with all leads & lifts as per relevant clauses of section 300.
Granular Sub-base as per Table:- 400-1 Construction of granular sub-base by providing graded Material, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface watering, rolling and compacting with vibratory power roller at OMC to achieve the desired density, complete as per clause 401. (A) Plant mix method (with Mechanically crushed stone only) (a) For Sub-base cum drainage layer or upper sub-base with (i) Grading- III Material
Wet Mix Macadam Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the material with water at OMC in mechanical mix plant carriage of mixed material by tipper to site, laying in uniform layers with paver in subbase / base course on well prepared surface and compacting with vibratory roller to achieve the desired density as per clause 406.
Prime coat Providing and applying primer coat with bitumen emulsion (SS-1, grade confirming to IS:8887) on prepared surface of granular base including clearing of road surface and spraying primer using mechanical means as per clause 502.
Tack coat Providing and applying tack coat with bitumen emulsion (RS-1, grade confirming to IS:8887) using emulsion pressure distributor on the prepared bituminous/granular surface cleaned with mechanical broom and as per clause 503. (ii) Granular surface treated with primes @ 0.30 kg/ Sqm
Dense Graded Bituminous Macadam Providing and laying dense bituminous macadam with minimum 40-60 TPH capacity HMP using crushed aggregates of specified grading, premixed with bituminous binder @ 4.0 to 4.5% by weight of total mix of mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher to the required grade, level and alignment, rolling with smooth wheeled,vibratory and tandem rollers to achieve the desired compaction as per MORTH specification clause No.505 complete in all respects. (B) With Mechanical paver (ii) for Grading II (26.5 mm nominal size bitumen content 4.50%)
Bituminous Concrete Providing and laying bituminous concrete with minimum 40-60 TPH capacity hot mix plant using crushed aggregates of specified grading, premixed with bituminous binder @ 5.0 to 6.0% by weight of total mix of mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MORTH specification clause No. 507 complete in all respects. (B) With Mechanical paver (iii) for Grading II (13.2 mm nominal size aggregate) with bitumen 6.0 %
Road Marking with Hot Applied Thermoplastic Compound with Reflectorizing Glass Beads on Bituminous Surface Providing and laying of hot applied thermoplastic compound as per MoRTH Grade 2.5 mm thick including reflectorizing glass beads @ 250 gms per sqm area,thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35-1997. The finished surface to be level, uniform and free from streaks and holes.
Construction of RCC open drain Construction of RCC open drain with width 0.60m or 0.45 m (inside dimension) and average depth from inlet to outlet 0.60m or 0.45 m (maintaing slope as per site conditions) with 120 mm thick RCC M-25 walls, 120 mm thick RCC M-25 bottom slab, over 100 mm thick (Av.) levelling course in PCC M-15 includingexcavation, dressing of sides and bottom, providing HYSD reinforcement consisting of 8 mm dia horizontal bars @ 150 mm c/c and U-shaped 8 mm dia bars @ 150 mm c/c including cutting,bending and binding wires, placing in position, providing shuttering and concreting by using cocrete mixer , compaction by vibration etc complete as per drawings and technical specifications. (i) 0.60 m width x 0.60 m average depth
0.45 m width x 0.45 m average depth
Providing and laying Pre cast RCC slab over RCC drain of required size made of grade RCC M-25 with 50mm dia perforation @ 600mm c/c in two rows in zig-zag pattern as per structural drawing including transportation of pre cast segements to work site and placing over drain as instructed by Engineer-in-charge. (i) Slab with reinforcement 1 Omm dia at 150mm c/c both ways (A) 690 mm wide and 120mm thick (for drain 450 x 450 mm)
840mm wide and 150mm thick (for drain 600 x 600 mm)
Providing & laying precast interlocking concrete blocks of required compressive strength with approved size, shape/ pattern over coarse sand bed of thickness 30 +/- 5 mm and joints filled with fine sand including leveling with surface vibrator, temping and sweeping etc. complete as per IRC-SP-63. (A) 60mm thick precast interlocking concrete block of C.C. M-30 grade on Footpath/Cycle Track (ii) Polymer coated coloured precast interlock concrete blocks
80mm thick precast interlocking concrete block of C.C. M-40 grade on Area of Light Traffic/ residential streets (ii) 80mm thick Polymer coated coloured precast interlock concrete blocks
Providing and fixing in position precast R.C.C. manhole cover and frame L D- 2.5 of required shape and approved quality 20.15.1) Rectangular shape 600x450mm internal dimensions
Boring/drilling bore well perfectly vertical for the specified depth suitable to receive required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer–in-charge upto 90 metre depth below ground level. (A) All types of soil 21.1.1.3) 150 mm dia.
Rocky strata including Boulders. 21.1.2.3) 150 mm dia.
150 mm dia.
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete 150mm thick as per standard design: 20.2.1) 100 mm diameter S.W. pipe
150 mm diameter S.W. pipe
Providing and fixing square-mouth S.W. gully trap grade 'A'’ complete with C.I. grating brick masonry chamber with well burnt modular clay bricks crushing strength not less than 35kg/cm2, water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : 20.3.3) 180x150 mm size P type
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) slotted pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 21.4.3) 150 mm nominal size dia.
Supplying, assembling, lowering and fixing in vertical position in bore well, ISI marked G.I. casing pipe (Plain) medium class in 4 to 7 meters length one end fitted with socket as per IS: 1239 (Part-1&Part-2) 1992 with IVth revision (Up-to-date amendments), of reputed & approved make, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer- in-charge. 21.5.3) 150 mm nominal dia
Constructing brick masonry manhole with well burnt modular clay bricks crushing strength not less than 35kg/cm2 in cement mortar 1:4 ( 1 cement : 4 coarse sand), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation in cement concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design : 20.7.1) Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) :
Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tube well as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 21.12.3) 150 mm clamp.
Supplying, filling, spreading & leveling stone boulders/ Gravels/ Coarse sand, in recharge pit, in the required layers and thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. (excavation of pit will be paid separately). 21.14.1) Stone boulders of size range 5 cm to 20 cm, in recharge pit
Gravels of size range 5 mm to 10 mm, over the existing layer of boulders
Coarse sand of size range 1.5 mm to 2 mm over existing layer of gravel
Providing and fixing water closet squatting pan (Indian type W.C. pan ), 100mm sand cast Iron P or S trap, 10 litre low level P.V.C. flushing cistern (same colour) conforming to IS : 7231, with flush bend and other fittings and fixtures complete including cutting and making good the walls and floors wherever required : 18.1.3) White Orissa pattern W.C. pan of size 580x440 mm
Providing and fixing vitreous china pedestal type water closet (European type) with inbuilt 10 litre low level vitreous china flushing cistern, ISI marked plastic seat and lid (same colour), mosquito proof coupling complete 18.12.1) White
Providing and fixing white vitreous china urinal basin with waste fitting as per IS : 2556, and other couplings in C.P. brass complete: 18.13.1) Flat back half stall urinal of size 460x380x250mm
Providing and fixing vitreous china wash basin with C.I. brackets, 32 mm C.P. brass waste of standard pattern, including painting of brackets, cutting and making good the walls wherever required : 18.17.6) White surgeon type Size 660x460 mm
Providing and fixing on wall face or under floor UV stabilized Unplasticised Rigid PVC pipes (single socketed) having 3.2mm wall thickness conforming to IS : 13592 (4kg/sqcm) including required couplers, jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion etc complete. 18.76.2) 110 mm dia pipe.
150 mm dia pipe.
75 mm dia pipe.
Providing and fixing on wall face UV stabilized Unplasticised - PVC moulded fittings/ accessories having 3.2mm wall thickness for Rigid PVC pipes conforming to IS : 13592 (heavy) jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. 18.77.1) Tee/ Tee with door/ Bend 45°/ Bend 90° 18.77.1.2) 110 mm
Double "Y" with or without door 18.77.2.2) 110 mm
Vent covel 18.77.3.2) 110 mm
Access door cap 18.77.4.2) 110 mm bend
Nahani trap 110x75mm
Multi floor trap 110
Plain reducing Tee 110x75mm
Providing and fixing UV stabilized Unplasticised -PVC pipe clips of approved design to Rigid PVC pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 18.78.2) 110 mm
Constructing masonry Chamber 30x30x50 cm, inside with modular well burnt clay bricks of 35 kg/ cm² in cement mortar 1:4 (1 cement : 4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) necessary excavation foundation concrete 1:5:10 ( 1 cement : 5 fine sand:10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick finished with a floating coat of neat cement complete as per standard design :
Constructing masonry Chamber 60x60x75 cm, inside with modular well burnt clay bricks of 35 kg/ cm² in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm. top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) necessary excavation foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design :
Providing and fixing on wall surface G.I. pipes medium class complete with G.I. fittings and clamps, including cutting, making good the walls etc. and testing of joints complete: 19.7.6) 50 mm dia. nominal bore
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. CONCEALED WORK including cutting chases and making good the walls etc., 19.5.1) 15 mm nominal outer dia .Pipes.
25 mm nominal outer dia .Pipes.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This included jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. EXTERNAL WORK 19.6.3) 25 mm nominal outer dia pipes
32 mm nominal outer dia pipes
50 mm nominal outer dia pipes
Making connection of G.I. distribution branch in G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete: (Dia of main line to be measured) 19.10.1) 25 mm nominal bore
32 mm nominal
50 mm nominal bore
Providing and fixing G.I. Union in G.I. pipe (New work) including cutting and threading the pipe and making long screws etc. complete: 19.11.1) 15 mm nominal bore
25 mm nominal bore
32 mm nominal
50 mm nominal bore.
Providing and fixing 15 mm nominal bore C.P. brass fittings of approved make and conforming to IS:8931 including C.P. brass extension if required: 19.14.1 Bib cock (400 grams)
Long body bib cock (500 grams)
Piller Cock (400 grams)
Two way bib cock (800 grams)
Stop cock (concealed) (600 grams)
Angle valve for basin mixer and geyser points (450 grams)
Toilet paper holder
Soap dish plate
Towel rail (600mm long x 20mm dia)
Towel ring (150 mm dia)
Basin mixer pillar tap with spout (1000 grams)
Kitchen sink mixer with cast swivel spout (1000 grams)
Wall mixer with elegant knob (1400 grams)
Hand shower set with flexible extension pipe
Bottle trap set with extension pipes
Toilet paper holder
Soap dish plate
Towel rail (600mm long x 20mm dia)
Towel ring (150 mm dia)
Health foscet (hand jet) with flexible connection pipe (for WC)
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end): 19.16.1) 25 mm nominal bore
32 mm nominal bore.
50 mm nominal bore
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 19.17.2) 20 mm nominal bore
Providing and fixing gun metal non- return valve (horizontal type) of approved quality (screwed end) : 19.18.4) 50 mm nominal bore
Painting G.I. pipes and fittings with synthetic enamel white paint over a red oxide zinc chromate priming coat, both of approved quality for new work: 19.21.4) 19.21.1 15 mm diameter pipe.
32 mm diameter pipe.
50 mm diameter pipe.
Providing and filling fine sand or coarser grade all-round the G.I. pipes in external work. 19.24.1) 15 mm diameter pipe
32 mm diameter pipe
50 mm diameter pipe
Constructing masonry Chamber 90x90x100 cm, inside with modular well burnt clay bricks of 35 kg/ cm² in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm. top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) necessary excavation foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design :
Providing and placing on terrace (at all levels) polyethylene water storage tank ISI marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
Wiring for light/ fan/ exhaust fan / call bell point with 3x1.5 sqmm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) with 5/6 amp modular switch, modular base and cover plate, suitable size G.I. box as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 1.7.1 Short Point
Medium Point
Long Point
Wiring for twin control light point with 3x1.5 sqmm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) with 5/6 amp modular switch, modular base and cover plate, suitable size G.I. box as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5)
Extra for providing and fixing light plug point on board in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) point wiring with modular type 3 pin 5/6 amp socket outlet and 5/6 amp switch including cost of base and cover plate and G. I. box etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5)
Wiring for light plug point with 3x2.5 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with modular type 6 Amp switch and 3 pin 6 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 1.10.1 Short Point
Medium Point
Long Point
Extra Long Point I
Extra Long Point II
Extra Long Point III
Wiring for power plug point with 3x4 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with modular type 16 Amp switch and 6 pin 16 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 1.11.1 Short Point
Medium Point
Long Point
Extra Long Point I
Extra Long Point II
Extra Long Point III
Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, wire in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 1.13.1 3 X 1.5 sq. mm in 20mm conduit
3 X 2.5 sq. mm in 20mm conduit
6 X 2.5 sq. mm in 25mm conduit
9 X 2.5 sq. mm in 32mm conduit
3 X 4 sq. mm in 25mm conduit
6 X 4 sq. mm in 32mm conduit
6 X 6 sq. mm in 32mm conduit
6 X 10 sq. mm in 40mm conduit
Supplying and fixing of following sizes FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with accessories in concealed complete as per specification and IS: 9537 (2000 Part 5) 1.15.1 20 mm
Extra for providing modular starter in power point wiring instead of modular 32 amp SPMCB and 16 amps socket outlet as per specification.
Wiring for light/ fan/ exhaust fan / call bell point with 3x1.5 sqmm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) with 5/6 amp modular switch, modular base and cover plate, suitable size G.I. box as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 2.7.1 Short Point
Medium Point
Long Point
Supplying and drawing following grade co-axial TV wire FR PVC insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ concealed Steel/FRLS PVC conduit as per specification 3.13.1 RG-6 grade
Supplying and drawing UTP 4 pair Cat 6 LAN wire in existing surface/ concealed Steel/FRLS PVC conduit as per specification and IS: 694 (2010)
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as per specification. 4.4.1 75mmX75mm (1/2 Module)
200mmX75mm (6 Module)
125mmX125mm (8 Module)
Supplying and fixing following modular switch, socket, other accessories on the existing modular plate & switch box including connections but excluding modular plate etc. as per specification. 5.4.1 5/6 amps one way switch
5/6 amps two way switch
Bell push
Fan regulator (two module size) electronic stepped type moving all rounds
RJ-45 {CAT6} socket outlet
RJ-45 {CAT6} LAN, I/O Box
Telephone socket outlet
T.V. antenna socket outlet
Blanking plate
Providing and fixing composite unit for computer points having modular type 1 No 6 pin 16 amp socket outlet, 1 No 16 amp switch, 3 Nos 3 pin 6 amp socket outlets, 3 Nos 6 amp switches, suitable G.I. box, base and cover plates, earthing the sockets and switch box including etc. as per specification.
Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts A.C. supply, complete as per specification. 5.7.2 Deluxe
Providing and fixing round/ hexagonal fan box (125mm dia) depth 75mm (max.) with 12mm dia steel bar hook, 1.6mm thick MS sheet cover, in RCC slab etc. as per specification.
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, including connection, earthing etc. complete as per specification.
Supplying and fixing of wall/ cabin fan including connection etc. as per specification. P.F. should be greater than 0.9 6.5.2 400 mm sweep
Supplying, installation, testing and commissioning of following sizes heavy duty (continuous running) 1400 rpm exhaust fan in existing opening in wall including earthing etc. complete as per specification. P.F. should be greater than 0.9 6.6.1 300 mm sweep
Supplying, installation, testing and commissioning of following sizes fancy exhaust fan having built in louvers in existing opening in wall including earthing etc. complete as per specification. P.F. should be greater than 0.9 6.8.1 225 mm sweep
300 mm sweep
Supplying and fixing following sizes of down rod of 15/20mm dia M.S. pipe of thickness 2 mm to ceiling fan including painting with matching colour etc. as per specification. 6.11.2 60 cm long
Providing and fixing phenolic laminated sheet cover of 180 mm dia 3 mm thick on the fan box etc. as per specification. (If provided at the time of installation of ceiling fan)
Supplying, installation, testing and commissioning of following LED fitting (luminaries) panel light in round/ square shape complete with electronic driver heat sink capacitor and all other accessories on surface/ in false ceiling etc. as per specification and P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 100 lumens /watt. 6.15.6 18/20 Watt
Supplying, installation, testing and commissioning of following sleek LED panel down lighters (luminaries) in round/ square shape complete with electronic driver heat sink capacitor and all other accessories on surface/ in false ceiling etc. as per specification and P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 100 lumens /watt. 6.16.2 36 watt, size 600 x 600mm
Supplying, installation, testing and commissioning of following COB LED Spot Light fitting complete with Electronic Driver Heat sink Capacitor and all other accessories including connection, earthing etc complete as per specification and IP20, P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 100 lumens /watt. 6.18.1 6 watt
Supplying, installation, testing and commissioning of following LED tube light fitting including batten with Electronic Driver Heat sink Capacitor complete with all other accessories on surface/ in false ceiling, including connection, earthing etc complete as per specification and IP20, P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 100 lumens /watt. 6.19.2 10 watt {2 feet}
18/20 watt {4 feet}
Supplying, installation, testing and commissioning of following LED Bulk Head fitting complete with Electronic Driver Heat sink Capacitor and all other accessories, including connection, earthing etc complete as per specification and P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 100 lumens /watt. IP65 6.27.1 10 watt
Fabrication, supply, installation, testing and commissioning of cubicle type compartmentalized wall/ floor mounted power cum control panel board of specified size and following depth made out of not less than 2 mm thick CRCA MS powder coated sheet with suitable size compartments for bus bars, switchgears and necessary cutouts for voltmeters, ammeters etc as per specifications including powder coating painting but without busbars, switchgears and other accessories etc complete as per specification. 7.19.1 Upto 300 mm deep
Above 300 mm and upto 450 mm deep
Above 450 mm and upto 600 mm deep
900 mm deep
Supply, installation, testing and commissioning of 4 pole (3 phase + neutral) aluminium bus bars in existing cubicle type compartmentalized wall/ floor mounted panel board along with suitable size and shape insulators, necessary bolts and nuts etc complete as per specification. 7.20.2 200 amp (30x5mm)
300 amp (50x5mm)
500 amp (75x6mm)
Providing and fixing following rating and breaking capacity MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as per specification, IS/ IEC: 60947-2 and Ics = 100 % Icu. 9.1.3 3 pole MCCB, 25-100A, Adjustable Thermal Release, 18KA
4 pole MCCB, 100A, Adjustable Thermal - Magnetic Release, 35KA
4 pole MCCB, 160A, Adjustable Thermal - Magnetic Release, 35KA
4 pole MCCB, 250A, Adjustable Microprocessor Release, 35KA
4 pole MCCB, 400A, Adjustable Microprocessor Release, 50KA
Supplying and fixing on surface/ recess following way, 240 volts SP&N MCB distribution board consumer unit of sheet steel phosphatized and powder painted, complete with tinned copper busbar, neutral busbar, earth bar, din bar, detachable gland plate, including interconnections, earthing etc. as per specification. (But without MCB/RCCB/Isolator) 9.3.3 2 + 12 way
Supplying and fixing on surface/ recess horizontal type following way, 415 volts, TPN MCB distribution board of sheet steel phosphatized and powder painted, complete with tinned copper busbar, neutral busbar, earth bar, din bar, detachable gland plate, including interconnections, earthing etc. as per specification. (But without MCB/RCCB/Isolator) 9.4.5 6 way Double door
Supplying and fixing on surface/ recess prewired horizontal type following way, 415 volts TP&N, MCB distribution board of sheet steel phosphatized and powder painted complete complete with loose wire box, terminal blocks, tinned copper busbar, neutral link, earth bar, din bar, detachable gland plate, duly prewired with suitable size FRLS PVC insulated copper conductor up to terminal blocks including interconnections, earthing etc. as per specification. (But without MCB/ RCCB/ Isolator) 9.8.5 4 way (4 + 12), Double door
Supplying and fixing SP MCB, 240 volts, 'C' curve, suitable for inductive load in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. 9.11.2 6 amps to 32 amps
Supplying and fixing DP MCB, 240 volts, 'C' curve, suitable for lighting and other loads in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. 9.12.2 6 amps to 32 amps
Supplying and fixing TP&N MCB, 440 volts, 'C' curve, suitable for lighting and other loads in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. 9.16.3 40 amps
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current up to 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. 9.22.2 40 amps
Providing and fixing metal clad, TP&N 4 pole automatic change over switch unit, 415/500 volts, including drilling holes on the board, connections, earthing the body, testing and commissioning etc. as per specification. 10.9.3 250 amps
Providing and fixing following rating current transformer in existing cubical panel including, connections, testing and commissioning etc. as per specification. 10.15.2 100/5 amps
Providing and fixing penal mounting 230 volt LED type indicating lamp in existing cubical panel including, connections, testing and commissioning etc. as per specification.
Providing and fixing penal mounting digital type ammeter of size 100x100 (NS) in existing cubical panel including, connections, testing and commissioning etc. as per specification
Providing and fixing penal mounting 0-500 volt voltmeter of size 100x100 (NS) in existing cubical panel including, connections, testing and commissioning etc. as per specification. 10.20.2 Digital type
For ammeter
Providing and fixing following Time switch (timer) in existing panel including connection, testing and commissioning as per specification. 10.22.1 Digital type
Providing and fixing panel mounting digital type VAF (Volt-amp-frequency combined) Multi Function meter of size 100x100 (NS) in existing cubical panel including connection, testing and commissioning etc. as per specification.
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe, with charcoal and salt as per specification and IS Code 3043: 1987(R 2016)
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe, with charcoal and salt as per specification and IS Code 3043: 1987(R 2016)
Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including soldering, excavation and refilling the trench etc. as per specification.
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including soldering, excavation and refilling the trench etc. as per specification.
Supplying and laying 25 mm X 6 mm G.I. strip at 0.50 metre below ground as strip earth electrode, including soldering, excavation and refilling the trench etc. as per specification.
Providing maintenance free earthing with following size GI pipe including making bore pit of minimum 150mm dia, providing and laying approved make Earthing Electrode of Pipe-in-Pipe technology as per IS 3043(R 2016) -1987 made of corrosion free G.I. Pipes having outer pipe of 80mm dia and inner pipe of 50mm dia and filling with specified qty highly conductive compound around pipe and above that with soft soil in bore pit complete and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. as per specification: 12.19.2 With 2 metre long GI Pipes and 25 kg back filling compound.
Supplying and laying ISI marked double wall HDPE pipe (IS 14930 Part II) having corrugation on the outer wall and plan surface on inner wall in ground below road, path etc at a depth not less than 40 cm and upto 90 cm including excavation, dismantling of road if required and refilling the trench with excavated material, ramming and making the surface good etc. as per specification. 14.1.3 90 mm outer dia and 75 mm Inner dia
200 mm outer dia and 170 mm Inner dia
Supplying and laying following size RCC Hume pipe class NP-2 (in standard length of 2 metre) with collar in ground below road, path etc at a depth not less than 50 cm and upto 90 cm including excavation, dismantling of road if required and refilling the trench with excavated material, ramming and making the surface good etc. as per specification. 14.4.3 200 mm dia
Supplying and laying following sizes one number FRLS PVC insulated /XLPE, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade in existing RCC/ HUME/ STONEWARE/ METAL/ HDPE pipe as per specification, IS: 1554 (1988, Part 1) / IS: 7098 (1988, Part 1). 15.3.11 3.5 x 25 sq. mm.
3.5 x 70 sq. mm.
3.5 x 95 sq. mm.
3.5 x 150 sq. mm.
3.5 x 300 sq. mm.
4 x 10 sq. mm.
4 x 16 sq. mm.
Supplying and laying following sizes one number FRLS PVC insulated, PVC sheathed, steel armoured, copper conductor control /power cable of 1.1 KV grade direct in ground including sand cushioning, protective covering etc as per specification and IS: 694 (2010). 15.12.5 4 x 16 sq. mm
Supplying and making end termination with brass compression gland and aluminum lugs for following size armoured aluminum conductor power cable of 1.1 KV grade as per specification. . 15.23.23 4 X 10 sq. mm (22 mm)
4 X 16 sq. mm (22 mm)
3½ X 25 sq. mm (25 mm)
3½ X 70 sq. mm (35 mm)
3½ X 95 sq. mm (38 mm)
3½ X 150 sq. mm (45 mm)
3½ X 300 sq. mm (63 mm)
Supplying and making end termination with brass compression gland and copper lugs for following size armoured copper conductor power cable of 1.1 KV grade as per specification. . 15.24.9 4 X 16 sq. mm (22 mm)
Supplying and installing following size of perforated hot dipped Galvanised Iron cable tray (Galvanisation thickness not less then 50 microns) with perforation not more than 17.5% rigidly suspended from the ceiling with G.I. suspenders at a distance not more than 2.5 metre and near every junction/ joint etc complete as per specification. 18.4.4 300 mm width X 50 mm depth X 1.6 mm thickness
450 mm width x 50 mm depth x 2.0 mm thickness
600 mm width X62.5 mm depth X 2.0 mm thickness
Supplying and fixing of following size of perforated hot dipped Galvanised Iron (Galvanisation thickness not less then 50 microns) cable tray "bends" (horizontal) turning at 90º in same plane with perforation not more than 17.5% rigidly jointed with cable tray etc. complete as per specification. 18.5.6 450 mm width X 50 mm depth X 1.6 mm thick
600 mm width X 62.5 mm depth X 2 mm thick
Supplying and erection DANGER BOARD made MS sheet duly painted and maked as per IE rules and specification.
Add or deduct for providing all additional parts/ equipments or for enhancing the capacity of parts/ equipments in automatic lift for 13 persons, speed 1.0 m/sec for every additional floor beyond initial G+3 floors.
Supplying, installation, testing and commissioning of centrifugal type mono-block electric pump set for water supply system having following capacity three phase, 415 volts AC induction motor and pump including suitable channel iron base frame, suitable C.C. foundation and connection of suction and delivery line etc. as per specification. 23.2.1 3 HP, 420 LPM, 20 m head, suction size 65 mm, delivery size 50 mm
Supplying and fixing following dia HDPE pipe PE-80 Grade (8kg/sqcm) in single length in the suction/ delivery line of water supply pump etc. as per specification. 23.6.3 63 mm outer dia
Supply, installation, testing and commissioning of 1-3 HP 1 phase submersible motor starter cum control wall/ floor mounted type made out of not less than 1.6 mm thick MS sheet and comprising of following panel mounting switchgears there in including connection inter-connection etc. as per specification. a) Phase indicating lamps with fuses and toggle switches 1 set b) 1/2/3 HP 1 phase DOL starter with over load and no volt relay 1 No c) 25 A "C" curve DPMCB 1 No d) Voltmeter 0-250 V 1 set e) Ammeter 0-10 A 1 set
Supplying, laying and fixing following size submersible cable along with GI/PVC/HDFC pipe line or laid in ground etc as per specification 23.14.3 3x4.0 sqmm
Supplying and making water proof joint with heat shrinkable joint kit including copper ferrules for following size of 3 core submersible copper conductor cable of 1.1 KV grade as per specification. 23.15.3 3x4.0 sqmm
Supplying of approved make split type Air Conditioner unit with cooling unit (copper coil) and condensing unit (copper coil) including 5 years compressor warranty and standard length of upto 3 metre of copper piping with insulation, etc complete as per specification: 24.3.7 3.0 ton Cassettee split type capacity 9000 kcal / hr.
Installation of split type Inverter/Non Inverter Air Conditioner unit, cooling unit on wall inside and condensing unit on out side wall/ ceiling/ floor at desired locations with existing standard length of copper piping with insulation and power cable including providing and fixing necessary good quality powder coated MS frame etc complete as per specification. (Extra length of copper piping and power cable shall be paid extra on linear basis)
Installation of cassettee type type Air Conditioner unit, cooling unit inside and condensing unit on out side wall/ ceiling/ floor at desired locations with existing standard length of copper piping with insulation and power cable including providing and fixing necessary good quality powder coated MS frame etc complete as per specification. (Extra length of copper piping and power cable shall be paid extra on linear basis)
Supply, connecting and fixing extra length of copper piping for split type air conditioners of following dia and approved quality with insulation sleave etc complete as per specification 24.10.1 5/8 "
Supplying, connecting and fixing 15mm dia PVC flexible drain pipe (reinforced with nylon threads) in drain outlet of split type air conditioners etc complete as per specification
Supplying of approved make Hiwall split Inverter type Air Conditioner unit with cooling unit (copper coil) and condensing unit (copper coil) including 5 years compressor warranty and standard length of upto 5 metre of copper piping with insulation etc complete as per specification: 24.20.8 1.5 Ton split type Inverter AC {5 Star}
2.0 Ton split type Inverter AC {5 Star}
All Control /communication wiring between indoor and Outdoor Units with FRLS PVC conduit and necessary clamps/saddling etc. complate as requird.
Supplying , installation , testing and commissioning of 6U Indoor Rack Wallmount 6U 450D With Front Glass Door Lock & Key 550 6U - loaded with cable manager + PDU + Fan complete as required.
UOM Name
Percentage
Per mile
Siemens Per meter
Activity unit
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 1.09 MB
3662590503382863201_153213_1258250143523725404_129113_Guidelines_to_Bidders_EPS_v1.pdf
NIT • 0.13 MB
8847772852613611261_190179_Approve Material List.docx
NIT • 0.02 MB
9164458629388199958_190179_Form A.doc
NIT • 0.15 MB
6726554938935893108_190179_NIT.doc
NIT • 0.28 MB
3460823154238841104_190179_PQ.doc
NIT • 0.28 MB
6854304274582446462_190179_Terms Condition.docx
NIT • 0.02 MB
7759759464724573077_190179_Notice.doc
NIT • 0.10 MB
6800827119279951816_190179_BOQ.xls
BOQ • 0.25 MB
Download all tender documents and submit your bid