| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.5 LAccepted-AOC | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹34.7 L+₹90,890 (2.69%)Rejected-Finance | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹36.4 L+₹2.6 L (7.66%)Rejected-Finance 131 SHINGANAPUR ROAD KOLKI KOLKI SATARA MAHARASHTRA 415523 | SATARA | MAHARASHTRA | 415523 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹36.7 L+₹2.9 L (8.70%)Rejected-Finance | L4 | Rejected-Finance Other than lowest |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
12 Nov 2024, 6:00 pmClosed
GE (AF) E/M CHAKERI KANPUR
GE (AF) E/M CHAKERI KANPUR
REPAIR MAINT AND SERVICEING OF SPLIT YPE AND WINDOW TYPE AIR CONDITIONERS AT TECHNICAL AREA AT AFS CHAKERI KANPUR
2024_MES_679599_1
8723/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Area under GE(AF) EM Chakeri Kanpur
AS PER NIT
9 documents required · 9 mandatory
₹500
GE(AF) EM Chakeri
₹90,000
Yes
22 Jan 2025
15 Oct 2024
18 Nov 2024
16 Oct 2024
12 Nov 2024
30 Oct 2024
Amount
M&L for servicing of window air conditioner 1/1.5 /2TR at various locations complete by cleaning/ filter/ condenser/ evaporator section with spraying water jet, and brushing, removing of dust/ dirt from air conditioner all over, check all electric connections, checking any leakage by applying soap solution on joints and liquid/ vapour lines properly. Cheking of functionally of spares of air conditioners and replacing the defective items supply under relevant item of schedule & rectifying the defects and put the air conditioners into operation complete all specified and directed by Engr-in-Charge. (Notes- (i)Spares shall me measured and paid saperately under relevent item of schedule (ii) As the nature of work is of daily maintanace of air conditioners contractor should deploy adequate trained technicians with helpers as intimated by Engineer in charge to rectify the complaint within 48 hours of receipt of complaint failing which penalty of Rs 200 per complaint per Day till the rectiication shall be charged from the contractor (iii) Contractor should make own arrangement for transportation of Air conditioners from site to workshop
M&L for servicing of split type AC (including indoor and outdoor units) of capacity 1.5/2 TR at various locations complete by cleaning of filters, indoor cooling coil, condenser coil with sparying water and brushing, removing of dust, dirt from air condtioners all over heck all electric connections, checking any leakage by applying soap solution on joints and liquid/ vapour lines properly. Cheking of functionally of spares of air conditioners and replacing the defective items supply under relevant item of schedule & rectifying the defects and put the air conditioners into operation complete all specified and directed by Engr-in-Charge. (Notes- (i)Spares shall me measured and paid saperately under relevent item of schedule (ii) As the nature of work is of daily maintanace of air conditioners contractor should deploy adequate trained technicians with helpers as intimated by Engineer in charge to rectify the complaint within 48 hours of receipt of complaint failing which penalty of Rs 200 per complaint per Day till the rectiication shall be charged from the contractor (iii) Contractor should make own arrangement for transportation of Air conditioners from site to workshop)
All as per item no.2 here in before but Tower AC of capacity 3.5 TR
Supply only Running capacitor 1.5 MFD ISI Marked of approved make
Supply only Running capacitor 2.5 MFD , ISI Marked of approved make
Supply only Running capacitor 4 MFD ISI Marked of approved make
Supply only Running capacitor 6 MFD ISI Marked of approved make
Supply only Running capacitor 36 MFD ISI Marked of approved make
Supply only Running capacitor 45+6 MFD ISI Marked of approved make
Supply only Running capacitor 50+6 MFD ISI Marked of approved make
Supply only Running capacitor 55+6 MFD ISI Marked of approved make
Supply only starting relay 1.5/2.0 TR/3.5 TR ISI Marked of approved make
Supply only thermostate switch with knob suitable for window AC
Supply only in replacement contactor relay for split/tower AC of capacity up to 3.5 TR AC, 415V, 50Hz, 3 Phase of approved .
M & L for disconnecting of u/s PCB from the unit of split AC/ window AC for repair / replacement of defective parts required to make servicable & reinstalling with the unit and making connections complete all as per specified and directed by Engr-in-Charge.
S & F replacement of MCB SP 240 Volt 32 Amp 10 KA capacity of approved make complete all as specified.
S & F in replacement Metal clad socket industrial 2pin & earth plug of 20A, 230V complete suitable for AC Box of approved make complete all as specified.
S & F in replacement Metal plug top industrial 2pin & earth plug of 20A, 230V complete suitable for AC Box. of approved make complete all as specified.
Supply only (NRV) suitable for window/split Ac of 1.5/2 TR of approved make complete all as specified.
Supply,fixing and replacement of Flare nut 6/8'' all as specified and directed by Engr-in-Charge.
Supply,fixing and replacement of Flare nut 5/8'' all as specified and directed by Engr-in-Charge.
Supply,fixing and replacement of Flare nut 3/8'' all as specified and directed by Engr-in-Charge.
Supply,fixing and replacement of Flare nut 1/2'' all as specified and directed by Engr-in-Charge.
Supply,fixing and replacement of Flare nut 1/4'' all as specified and directed by Engr-in-Charge.
Supply,fixing and replacement of Dead nut 6/8'' all as specified and directed by Engr-in-Charge.
Supply,fixing and replacement of Dead nut 5/8'' all as specified and directed by Engr-in-Charge.
Supply,fixing and replacement of Dead nut 3/8'' all as specified and directed by Engr-in-Charge.
Supply,fixing and replacement of Dead nut 1/2'' all as specified and directed by Engr-in-Charge.
Supply,fixing and replacement of Dead nut 1/4'' all as specified and directed by Engr-in-Charge.
Supply,fixing and replacement of suction valve 6/8'' all as specified and directed by Engr-in-Charge.
Supply,fixing and replacement of suction valve 5/8'' all as specified and directed by Engr-in-Charge.
Supply,fixing and replacement of suction valve 1/2'' all as specified and directed by Engr-in-Charge.
Supply,fixing and replacement of Discharge valve 3/8'' all as specified and directed by Engr-in-Charge.
Supply,fixing and replacement of Discharge valve 1/4'' all as specified and directed by Engr-in-Charge.
Supply fix in replacement OLP relay suitable for 1.5 TR/2.00 TR AC of approved make complete all as specified.
Supply only copper liquid line filter 3 way suitable for copper pipe of 3/8 dia for window/ split AC
Supply and fix in replacement Copper pipe 5/8 " outer dia all as specified and directed by Engr-in-Charge.
Supply and fix in replacement Copper pipe 3/8 " outer dia all as specified and directed by Engr-in-Charge.
Supply and fix in replacement only Copper pipe 1/2 " outer dia all as specified and directed by Engr-in-Charge.
Supply and fix in replacement Copper pipe 1/4 " outer dia all as specified and directed by Engr-in-Charge.
S & F in replacement copper pipe insulation of any size complete suitable for split /Tower AC all as specified and directed by Engr-in-Charge.
M&L for dismantaling, disconnecting u/s compressors from Split /window AC of capacity 1.5 TR and replacement with new HSCM compressor (rotary type) on mountings such as rubber pads, nut, bolt, wahers and breezing suction and discharge lines properly, making electrical connections, checking and leakage at joints and vaccuming the system all as specified and directed by Engr-in-Charge. Note: Serial Number of Sealed Compressor shall be entered in MB.Contractor shall submit manifecturer's test certificate of compressor.
All as per item no. 42 here in before but Rotary Compressor for 2.0 TR AC, 220V, Single Phase.
All as per item no. 42 here in before but Reciprocating compressor for 1.5 TR AC 220 V.
All as per item no. 42 here in before but Reciprocative compressor for 2.0 TR AC 220 V.
All as per item no. 42 here in before but Scroll compressor of capacity 3.5 TR AC, 415V,50Hz , Three phase
M & L transportaion of air conditioner from site to work shop for defecting leakage from the close circuit of window air conditioner 1/1.5/2.0 TR capacity, rectifying the leakage by breezing of copper rod using by butane gas flame, vaccuming the system after rectification of leak charging nitrozen and holding the pressure not less than 24 hours or as specified and directed by Engr-in-Charge & refixing back to its original position at site.(Note:- Cost of brazzing rod, butane gas cartridge and nitrogen shall be included in the quoted rates)
M & L for dismantling of Indoor unit split Air conditioner of capacity 1.5/2 TR transporting from site to workshop for defecting leakage from the close circuit of split air conditioner of rectifying the leakage by breezing of copper rod using by butane gas flame, vaccuming the system after rectification of leak charging nitrozen and holding the pressure not less than 24 hours or as specified and directed by Engr-in-Charge & refixing back to its original position at site.( Note:-Cost of brazzing rod, butane gas cartridge and nitrogen shall be included in the quoted rates)
M & L for dismantling of outdoor unit Split Air conditioner of capacity 1.5/2.0 TR transporting from site to workshop for defecting leakage from the close circuit of Split air conditioner of rectifying the leakage by breezing of copper rod using by butane gas flame, vaccuming the system after rectification of leak charging nitrozen and holding the pressure not less than 24 hours or as specified and directed by Engr-in-Charge & refixing back to its original position at site. ( Note:-Cost of brazzing rod, butane gas cartridge and nitrogen shall be included in the quoted rates)
M & L for defecting leakage from the close circuit of Tower air conditioner of capacity 3.5 TR rectifying the leakage by breezing of copper rod using by butane gas flame, vaccuming the system after rectification of leak charging nitrozen and holding the pressure not less than 24 hours or as specified and directed by Engr-in-Charge & refixing back to its original position at site.( Note:-Cost of brazzing rod, butane gas cartridge and nitrogen shall be included in the quoted rates)
M & L for charging of refrigerent R-22 in window / split AC of capacity 1/1.5/2.0/3.5 TR capacity after detection and rectification of leakage under relevant items of schedule and testing complete all as specified and directed by Engr-in-Charge.
All as per item no. 51 here in before but charging of refiregent R-32
All as per item no. 51 here in before but charging of refiregent R-410
Supply only refrigerent R-22 gas suitable for split/ window type air conditioner in empty cylinder at AGE E/M-III storeyard complete all as specified and directed. Note: (i) Empty cylinder will be provided by the department for filling up refrigerent. (ii) Refrigerent gas purchase voucher shall be provided by the contractor. (iii) The refrigerent shall be taken on ledger charge with receipt voucher and issued as per requirement complete all as specified and directed.
All as per item no. 54 here in before but refrigent R-32
All as per item no. 54 here in before but refrigent R-410
M&L for disconnecting and dismentaling of blower/ condenser fan motor of window air conditioner of capacity 1.5/2.0 TR transporting for civil workshop and rewinding with new super enamelled copper conductor/ wires of superior quality with same gaudge and assembling with the AC unit and testing and commisioning complete all as specitfied directed by Engr-in-Charge.
All as per item no 57 but fan motor of out door unit of split type air conditioner of capacity 1.5/2.0 TR
All as per item no 57 but but fan motor of Tower AC 3.5 TR capacity
S&F in replacement of single phase electric motor AC of indoor unit capacity 1.5/2.0 TR split AC as per existing make and sample as per site requirement all as specified and directed by Engr-in-Charge.
S&F in replacement of single phase electric motor DC of indoor unit capacity 1.5/2.0 TR split AC as per existing make and sample as per site requirement all as specified and directed by Engr-in-Charge.
M & L for disconnecting and leak almunium condenser coil from split air conditioner of capacity 1.5/2.0 TR and supply & fixing of new copper tube condenser coil of suitable size as per sample and make and fixing with the outdoor unit of air conditioner vaccuming the system complete and commissioning after fixing complete all as specified and directed by Engr-in-Charge.
S&F replacement sheet metal enclosure, 32 Amp single pole and nutral with a two pin and earth plug socket complete metal clad board (industrial type with MCB 32 Amp fix properly all as directed by Engr-in-charge.
M & L for factory made MS Stand, powder coated of suitable size to mount outdoor unit of capacity 1.5/2.0 TR split AC with and including GI nut bolts of suitable size complete all as specified and directed.
Supply of Copper rod for brezzing complete all as specified & directed by Engr-In-charge.
S & F Nylon stranded PVC flexible pipe drain pipe of size 15 mm of length up to 3 mtr as per sample all as specified & directed by Engr-In-charge.
S & F in replacement PVC insulated & sheathed round multi stranded copper conductor 2.5 sq mm 3 core 1100 Volts graded complete all as specified & directed by Engineer in Charge.
Supply and fix in replacement fan blade for window AC of 1.5/2.0 TR capacity as per existing make and sample and as specified and directed by Engr-in-Charge.
Supply only Butane gas cartridge container not less then 230 grms or standard available in market for all as specified and dircted
S&F replacement of condenser fan blade of outdoor unit of split type air conditioner 1.5/2.0 TR capacity as per make & sample and all as specified and directed by Engrin Charge.
M&L for disconnecting of burnt PCB from the unit and supply and fixing of new PCB of window AC of cap of 1.5/2.0 TR of approved make/model as per OEM, including testing and commitioning all as specified & directed by Engr-in-charge.
M&L for disconnecting of burnt PCB from the unit and supply and fixing of new PCB of split AC of cap of 1.5/2.0 TR of approved make/model as per OEM, including testing and commitioning all as specified & directed by Engr-in-charge.
S&F in replacement of condenser fan motor including mounting base, rubber, clips, as per existing make and soft length in split type AC of 1.5/2.0 TR capacity complete all as specified and directed.
S&F swing motor any type, split/ window type AC of 1.5/2.0 TR capacity complete all as specified and directed.
S&F black insulation Tap 4" wide and up to 50 feet complete all as specified and directed.
M & L for rewinding of burnt transformer of voltage stablizer of capacity 5 KVA with new super enameled copper conducter winding wire of existing gauge , including proper insulation and assembling with the stablizer complete all as directed by Engr-in-Charge.
S & F in replacement of relay 25/30 Amps, 24 Volt make and capacity of 5 KVA voltage stabilizer complete all as specified & directed.
S & F in replacement of main PCB with high and low voltage cut off PCB suitable for 5 KVA voltage stabilizer suitable making for existing all as specified & directed.
S & F window AC kit for 1.5 TR of approved make complete all as specified & directed.
S & F window AC kit for 2.0 TR of approved make complete all as specified & directed.
S & F split AC kit indoor unit for 1.5 TR of approved make complete all as specified & directed.
S & F split AC kit indoor unit for 2.0 TR of approved make complete all as specified & directed.
S & F split AC kit outdoor unit for 1.5 TR of approved make complete all as specified & directed.
S & F split AC kit outdoor unit for 2.0 TR complete all as specified & directed.
Supply,fixing and replacement of Timer for Tower AC complete all as specified & directed.
Supply,fixing and replacement of new remote with leak proof battery of suitable size of make as per OEM , including configuring with the AC unit complete all as specified & directed.
Supply,fixing and replacement of coling coil senser complete all as specified & directed.
Supply,fixing and replacement of remote battery complete all as specified & directed.
Supply only Charging set with suiatble gaudge-02, three charging line complete all as specified & directed.
Supply only gulli pench fasner of size up to 50mm long in Box / Packet containing 100 Nos fateners complete all as specified & directed.
Supply only Insulation Tape White of size 4" and 50 feet long complete all as specified & directed.
Supply only Taflon Tape Role White colour complete all as specified & directed.
Supply only Thimble of any type and size in Box containg 100 Nos complete all as specified & directed.
keerti trading corporation (BID ID -3163089)
VISHAL TRADERS (BID ID -3157563)
PAWAN COOL CORPORATION (BID ID -3158285)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .