Loading…
Loading…
Tender Value
₹5.6 Cr
EMD Value
₹11.3 L
Closing Date
8 May 2026, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
SRDSTECSIG
14 conditions · 2 needing a document upload
Financial Eligibility Criteria: The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Form-2, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
Technical Eligibility Criteria: The Tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i)Three similar works costing not less than the amount equal to 30% of advertised value of the tender, or (ii)Two similar works costing not less than the amount equal to 40% of advertised value of the tender, or (iii)One similar work costing not less than the amount equal to 60% of advertised value of the tender.
Defination of Similar Work :- "Any signalling work involving trenching, cable laying, termination and outdoor wiring. Note 1:- Tenderer maybe required to submit the schedule of those works completion/performance certificate of which have been submitted by him/her in support of 30 /40/ 60 % (as the case may be) criterion of similar nature of work.
14 conditions · 9 needing a document upload
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
PAN Number to be attached.
Detail of Bid Security paid, through only payment modes available on IREPS portal like net banking, debit card, credit card etc.
Registered Office Address with contact no.
Mandatory undertaking regarding Employment/Partnership of Retired Railway Employees as per Clause No. 12 of Chapter-I as per Annexure- E.
Mandatory certificate to be submitted by tenderer along with tender documents as per Annexure- A.
GST Number to be attached.
Mandatory Power of Attorney to be submitted by tenderer along with tender documents as per Annexure- B.
MOA & AOA, Resolution of Board and POA, Sole Proprietorship, Notarized partnership deed with POA and latest certificate of registration with Registrar of the firms must be attached. Year of Formation / Incorporation. (As per Clause-10 of Tender Document)
Upload duly filled and signed Cover Letter (Tender Form 1).
Mandatory Document Tenderer uploaded Annexure-A (1) {This certificate is to be given by attorney/authorized signatory/each member of Partnership firm/Joint Venture (JV)/Hindu Undivided Family (HUF)/Limited Liability Partnership (LLP) etc.)}of tender documents.
An undertaking by the tenderer shall be provide at the time of tender submission that the equipment shall be procured from RDSO/TEC/OEM covering supply, installation, testing, commissioning of system including after sales support required during the warranty period.
Improvement works in section under Sr.DSTE-I for enhancement of reliability and focus on PRIME items.
558-Sig-16-M-Tender-1470
558-Sig-16-M-Tender-1470
Open
Works - General
12 Months
Delhi, Delhi
₹0
₹11.3 L
8 May 2026
15 Apr 2026
24 Apr 2026
197 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 5,64,22,152.38 | ||
| — | 900.00 | — | — | ||
| Charging of Lead Acid Batteries 2V 300AH/ 500 AH with contractors own battery grade sulphuric acid and distilled water with minimum two charge - discharge cycles, installation of charged batteries in groups & their connection & wiring. The work shall be done as per extant practice of N.Rly & instruction of Engineer in-charge. Detailed measurements of initial charging shall be recorded jointly by contractor & Rly's site-in charge. Inspection: Consignee. | — | — | — | 8,00,775 | |
| — | 60.00 | — | — | ||
| Charging of lead acid secondary cells of 80 AH capacity as per standard charging procedure (with contractor charging equipment). All charging materials i.e. Sulphuric acid conforming to latest IRS specs and distilled water as per IRS specs will be supplied by contractor. This also includes installation of secondary batteries, their interconnection and writing work. Inspection: Site Engineer | — | — | — | 14,597.4 | |
| — | 25.00 | — | — | ||
| Supply of Electric point machine, non-trailable type conforming to RDSO Spec no.IRS:S.24/2002 amendment no.1 or later with the following parts (a) 220mm throw with interlocking for operation of the point as per RDSO Drg.no.S-/11000 with AC immunity of 160 volt (RMS),50 HZ.(b):-Clamp point lock 60kg for BG as per RDSO Drg no. S-3395A.(c):-Switch extension Bracket ( P- Bracket) and insulation plates as per RDSO Drg.no S-3591,3592 & 3593.(d) Detector rods (Long & Short) as per RDSO drg no.S-3596-97. (e) Drop lug as per RDSO drg no S-3598 including all insulation and accessories Electric Point Operating Machine-IRS Type 220 mm Throw, High thrust (AC Immunity 160V AC), non-trailable to operate on 110V DC complete with Lock & Detector slides, Cable terminal Box and Clamp Lock & Ground Connections. Confirming to IRS : S 24 / 2002 & Assy. Drg. No.- RDSOS/11000 & for Motor IRS: S 37 / 82 Inspection: RDSO | — | — | — | 43,73,744.25 | |
| — | 20.00 | — | — | ||
| Supply of ELECTRIC POINT MACHINE 143 MM143STROKE AC IMMUNITY 400V AC COMPLETE WITHLOCK DETECTOR AND SLIDES FOR LOCKDETECTOR NON -TRILABLE TO OPERATE ON 110V DC ROTARY LOCKING WITH CRANK HANDLEUNIVERSAL TPE AS PER RDSO SPECN. NO.IRS:S- 24/2002 (AMND 1) RDSO DRG. NO S-10800 (ALT.5) WITH JUNCTION BOXTELESCOPIC. THE MOTOR WILL BE AS PER RDSOSPECN. NO. IRS: S-37/82 (AMND. 3) WITH RDSODRG. NO. S-10910. This includes supply of Set of tools as per para20.1 & 20.2 of RDSO SPECN.NO. IRS:S-24/2002 (AMND 1) 20.1 The following set of tools in a suitable tool box shall be supplied along with every set of eight- point machines or less. i). Hand operated square drive socket wrenches of 12.5 mm driving square (short type) as per IS: 7381 for M8, M10, M12 & M18 threads. (One 250 mm long 12.5 mm square extension bar as per IS: 7991 along with compatible Tee handle square drive as per IS: 7975 suitable for above socket wrenches shall also be provided.) ii). Open jaw wrenches (spanners) for M10, M12, M20, M24 & M33 threads as per IS: 2028. iii). Adjustable wrench. iv). Screw driver 300 mm long. 20.2 Junction box and two numbers of telescopic pipes of approved type shall be supplied as an integral part of the point machine. Inspection: RDSO. | — | — | — | 13,39,219.4 | |
| — | 20.00 | — | — | ||
| Fabrication & Supply of complete set of point rodding for point machines of IRS type or its equivalent type as per. drg. No. SA 8800-01 (Adv) or latest along with 'P' brackets and 'L' bracket required (coal Bengal for smithy work, all type of nuts & bolts and Lugs as required also to be supplied by contractor with each set) , Inspection: Consignee. | — | — | — | 1,94,084.8 | |
| — | 45.00 | — | — | ||
| Fixing, wiring, testing & adjustment of point machines as per standard practice. It also includes: - i) Fixing of switch extension 'P' bracket, providing insulation for switch extension bracket, fixing ground connections, adjusting the correct opening of switches and adjusting the point machine with crank handle. ii) Wiring inside the point machine, erection & wiring of JB with lock & key as per drawing, provided with terminal strips. iii) Supply & fixing of GI pipes with flange for taking cable in to point machine and junction Box through gland/GI pipe. iv) Complete material for installation viz. point insulation material, Jn. box, GI pipe, gland pipe, wiring material, nut & bolts of various sizes, angle iron of size 75mmx75mmx10mm, channels for fixing the machine, lugs for point rodding and insulation materials for stretcher bar 90R/52kg/60kg as per.drg.no.SA-23172 (adv.) Alt.1 will be supplied by the contractor. v) Smithy and fitting work required at site for complete installation of Gauge tie plate and insulation of GTP as per approved Drg.no.NR/S&T/CON/7-6/97 and William stretcher bar (if reqd.) will be done by the contractor. Machine shall be overhauled by contractor if required. vi) This includes removal of existing gears and fixing the machine at raised level on channel as per standard practice to avoid flooding wherever required. vii) Supply of ground connections of electric point machine, non-insulated GTP & CTP extension plate, Junction box and stretcher bar shall be made available by the Rlys. in which the supply of ground connections, Jn box is covered separately. Inspection: Site Engineer | — | — | — | 3,85,737.3 | |
| — | 45.00 | — | — | ||
| Supply and fixing of Spigot for point machines. (Job = Per Point Machine). Inspection: Consignee | — | — | — | 11,591.55 | |
| — | 16.00 | — | — | ||
| Supply, installation & wiring of Earth leakage detector (12 Channel) for monitoring different AC and DC, supplies including all accessories as per. specification no. RDSO/SPN/256/2002 or latest. Inspection: RDSO for supply portion, execution: Site Engineer. | — | — | — | 26,24,452.16 | |
| — | 7.00 | — | — | ||
| Supply, installation, wiring, validation, testing & commissioning of Data logger for maintenance of 512 port digital input and 32 port analog input with built in network internal modem and power supply as per RDSO Specification No. S/99/2006(Amendment-3) with latest amendments or as per latest specification along with data logger failure analyzer system, furniture set (Specification as in special condition of tender documents) and technical conditions of the tender document. INSPECTION:RDSO for supply portion other than furniture, Execution and furniture: Site Engineer. | — | — | — | 50,45,037.06 | |
| — | 10.00 | — | — | ||
| Supply and installation of Automatic Media changeover of modems working on redundant channels for data transmission on OFC/Quad to work with UFSBI (as per IRS:S-104/2012). Inspection: Consignee. | — | — | — | 4,80,258.3 | |
| — | 12.00 | — | — | ||
| Supply of WHEEL SENSOR WITH 5 MTR MOULDED CABLE 60KG COMPATIBLE WITH EXISITING FRAUSHER MSDAC as per RDSO Specification No. RDSO/SPN/176/2013 (Version.3) OR LATEST. Inspection: RDSO. | — | — | — | 20,62,219.92 | |
| — | 5.00 | — | — | ||
| Supply of Tx Coil for HASSDAC asper RDSO Specification No. RDSO/SPN/177/2012 with Version 3 or Latest : CEL make. Inspection: RDSO. | — | — | — | 55,376.85 | |
| — | 5.00 | — | — | ||
| Supply of Receiver Coil (Rx Coil) for HASSDAC as per RDSO Specification No. RDSO/SPN/177/2012 with Version 3 or Latest Make : CEL. Inspection: RDSO. | — | — | — | 55,376.85 | |
| — | 15.00 | — | — | ||
| Supply of TRACK DEVICE (AXLE COUNTER) AS PER RDSO SPEC. NO. RDSO/SPN/177/2012 VERSION 3.0 OR LATEST RX 21/25 KHZ SUITABLE FOR SSDAC OF GGTRONICS MAKE (15 mtr). MAKE/BRAND GGTRONICS. Inspection: RDSO. | — | — | — | 6,50,401.8 | |
| — | 15.00 | — | — | ||
| — | — | — | 6,57,122.1 | ||
| — | - Supply OF | of TRACK DEVICE VERSION 3.0 OR GGTRONICS MAKE. | AS PER SUITABLE RDSO. | ||
| — | 4.00 | — | — | ||
| Supply of Web detector set of Medha Make Single Section Digital Axle Counter consisting of TX Coils 31KHz/36KHz assembly- 01 Nos as per RDSO Specification No. RDSO/SPN/177/2012 Version 3 or latest.Inspection: RDSO. | — | — | — | 2,01,072 | |
| — | 80000.00 | — | — | ||
| Laying of signalling/Telecom/power cables of different sizes as per approved Drg. No. NR/S&T/CON/1-1/97A and as per cable route plan approved by Railways and meggering of cable before and after its laying of all type of outdoor cables. Inspection: Site Engineer | — | — | — | 6,54,400 | |
| — | 10000.00 | — | — | ||
| Excavating and refilling of trench in Normal Soil to the level of ground with rammed earth as per approved Drg. No.NR/S&T/CON/1-1/97A. Aso as not to form a drain 0.3 Mtrs. Wide & 1 Mtr. Deep on both side of the station alongside the track. It shall conform to the safe distance as per signalling and cable plan. It also includes clearance of rooots of trees & bushes. Inspection: Site Engineer. | — | — | — | 8,05,400 | |
| — | 2000.00 | — | — | ||
| Excavating and refilling of trench in Rocky soil to the level of ground with rammed earth as per approved Drg. No.NR/S&T/CON/1-1/97-A1 so as not to form a drain 0.3 Mtrs. Wide & 0.5Mtr. Deep on both side of the station alongside the track .This includes 50mm thick concreting work throughout in 1:3:6 ratio. All concreting material to be supplied by the contractor. It shall conform to the safe distance as per signalling and cable plan It also includes clearance of routes of trees & bushes. Inspection: Site Engineer. | — | — | — | 2,53,520 | |
| — | 80000.00 | — | — | ||
| Supply and laying of 2nd class bricks in the trench and laying as per approved Drg. No.NR/S&T/CON/1-1/97A as per instructions of the site Engineer. Inspection: Site Engineer. | — | — | — | 6,49,600 | |
| — | 1200.00 | — | — | ||
| Supply and fixing of G.I. pipe perforated at a distance of 20 CM or less of required length at culverts/ bridges/along the cuttings, suitably concreted at both ends as per drg. No. (NR/S&T/CON/1. 4/97) or at ASM office / other buildings suitably fixing it to the wall and at both ends. G.I. clamps of M.S. flats bolts and nut, to be supplied by the contractor. G.I. pipe 75/80 mm dia, 3mm thick. Inspection: RITES for supply portion. | — | — | — | 10,31,928 | |
| — | 1000.00 | — | — | ||
| All work of horizontal boring and trenchless cabling along with supply,transpotation and insertion of double wall corrugated pipe -( ISI marked ) conforming to RDSO Spec no. RDSO/SPN/204/2011, and the laying of cable in the boring under the track / road etc as per instruction of site engg. by using pipe of size 120 mm outer dia, 103.5 mm inner dia in which required number of cables to be crossed. The depth of horizontal boring should be minimum 1.0 m from rail flange/road level. Inspection : RITES for DWC pipe. | — | — | — | 21,89,250 | |
| — | 2700.00 | — | — | ||
| HDD Boring & Trenchless of 120mm dia without HDPE pipe for laying of signalling/ telecom / power cable under Track /Road/Culvert etc cable laying is covered separately. Inspection: Site Engineer. | — | — | — | 26,09,280 | |
| — | 50.00 | — | — | ||
| Supply of single app.case steel RE with 'E' type lock and key ward no.42 and handle as per drg. No. RE/S&T/ALD/SK/219/82 with (Alt A) and 221/82 with Alt.B. Inspection :RITES | — | — | — | 11,03,758.5 | |
| — | 50.00 | — | — | ||
| Casting, concreting and curing of foundation and erection of single app.cases of size (1160mmx760mm) at surface and 650mm deep as per approved Drg.No.NR/S&T/CON/2-7/97. A layer of 3 mm of bitumen compound has to be provided between foundation and location box to prevent ingress of water in the base of location box. All material such as cement, coarse sand, aggregate and anchor bolt shall be supplied by contractor. App. Case single will be supplied by Railway. Contractor is required to execute all type of repair Works of foundations if required during inserting the cable for termination. Inspection: Site Engineer | — | — | — | 2,89,522 | |
| — | 20.00 | — | — | ||
| Preparation of App. Case single involving wiring of relays. Preparation & fixing of bakelite hylum sheet 910x800x6mm and backelite shelf 900x450x10mm duly fixed by angle iron piece of different size inside all the app. Cases. Hylum board shall be fixed on an angle iron frame of 25mmx25mmx3mm. Angle iron frame will be fixed in location boxes secured by nuts and bolts.This includes fixing of fuses, ARA terminal, Q series relays and other type relays on square bars fixing and jamming of cables with 2 inch thick salwood plank provided at the bottom. This will include opening, pasting and jamming armour of each cable in the hole drilled separately for each cable through the salwood plank and all cable entry points on location boxes, location huts, JBs relay room/battery room to be closed with suitable masonry Works covered with sand and plastering.Wiring description for terminal drawing of circuits, inside app. Case. Painting from out side as well inside with red oxide and aluminum paint is covered separately. Size of lettering will be 100mm or as per instructions of Engineer at site. All materials including Backelite shelf, hylum board, salwood plank, angle iron square bar, wire and wiring material as per the IRS specn., non deteriorating type HRC fuses with bases, catenary wires , nuts and bolts and other items shall be supplied by the contractor. Relays, ARA terminals only shall be supplied by the Railways. Inspection: Site Engineer. | — | — | — | 1,23,097.2 | |
| — | 30.00 | — | — | ||
| Preparation of App. Case single not involving wiring of relays. Preparation & fixing of bakelite hylum sheet 910x800x6mm and Backelite shelf 900x450x10mm duly fixed by angle iron piece of different size inside all the app. Cases. Hylum board shall be fixed on an angle iron frame of 25mmx25mmx3mm. Angle iron frame will be fixed in location boxes secured by nuts and bolts.This includes fixing of fuses, ARA terminal and fixing and jamming of cables with 2 inch thick salwood plank provided at the bottom. This will include opening, pasting and jamming armour of each cable in the hole drilled separately for each cable through the salwood plank and all cable entry points on location boxes, location huts, JBs relay room/battery room to be closed with suitable masonry Works covered with sand and plastering.Wiring description for terminal drawing of circuits, inside app. Case. Painting from out side as well inside with red oxide and aluminum paint is covered separately. Size of lettering will be 100mm or as per instructions of Engineer at site. All materials including Backelite shelf, hylum board, salwood plank, angle iron square bar, wire and wiring material as per the IRS specn., non deteriorating type HRC fuses with bases, catenary wires , nuts and bolts and other items shall be supplied by the contractor. ARA terminals only shall be supplied by the Railways. Inspection: Site Engineer | — | — | — | 1,46,674.2 | |
| — | 15.00 | — | — | ||
| Supply of apparatus case steel RE half with E type lock and key ward no.42 and handle as per drg.no. RE/S&T/ALD/SK/220/82 and 221/82 with Alt.B. Inspection :RITES | — | — | — | 2,46,953.55 | |
| — | 15.00 | — | — | ||
| Casting, concreting and curing of foundation and erection of half app.cases of size (670mmx760mm) and 650mm deep as per Drg. No. NR/S&T/CON/2. 8/97. A layer of 3 mm of bitumen compound has to be provided between foundation and location box to prevent ingress of water in the base of location box . All material such as cement, coarse sand, aggregate and anchor bolt shall be supplied by contractor. App. Case half will be supplied by Railway. Contractor is required to execute all type of repair Works of foundations if required during inserting the cable for termination. Inspection: Site Engineer. | — | — | — | 75,992.1 | |
| — | 5.00 | — | — | ||
| Preparation of Apparatus Case (location box) half involving wiring of relays. Preparation and fixing of bakelite hylum sheet 450x800x6mm and Backelite shelf 450x450x10mm duly fixed by angle iron piece of different size inside all the app. Cases. Hylum board shall be fixed on an angle iron frame of 25mmx25mmx3mm. Angle iron frame will be fixed in location box secured by nuts and bolts. This includes fixing of fuse ARA terminal, Q series relays and other type of relays on square bars, fixing and jamming of cable with 2 inch thick salwood plank provided at the bottom. This will include opening, pasting and jamming armour of each cable in the hole drilled separately for each cable through the salwood plank and all cable entry points on location boxes, location huts, JBs relay room/battery room to be closed with suitable masonry Works covered with sand and plastering. Wiring description for terminal drawing of circuits, inside app. Case. Painting from out side as well inside with red oxide and aluminum paint is covered separately. Size of lettering will be 100mm or as per instructions of Engineer at site. All materials including Backelite shelf, hylum board, salwood plank, angle iron square bar, wire and wiring material as per the IRS specn., non deteriorating type HRC fuses with bases,catenary wires, nuts and bolts and other items shall be supplied by the contractor. Relays, ARA terminals only shall be supplied by the Railways. Inspection: Site Engineer | — | — | — | 21,896.8 | |
| — | 10.00 | — | — | ||
| Preparation of App. Case half not involving wiring of relays. Preparation and fixing of Bakelite hylum sheet 450x800x6mm and Backelite shelf 450x450x10mm duly fixed by angle iron piece of different size inside all the app. Cases. Hylum board shall be fixed on an angle iron frame of 25mmx25mmx3mm. Angle iron frame will be fixed in location box secured by nuts and bolts. This includes fixing of fuse ARA terminal and fixing and jamming of cable with 2 inch thick salwood plank provided at the bottom. This will include opening, pasting and jamming armour of each cable in the hole drilled separately for each cable through the salwood plank and all cable entry points on location boxes, location huts, JBs relay room/battery room to be closed with suitable masonry Works covered with sand and plastering.Wiring description for terminal drawing of circuits, inside app. Case. Painting from out side as well inside with red oxide and aluminum paint is covered separately. Size of lettering will be 100mm or as per instructions of Engineer at site. All materials including Backelite shelf, hylum board, salwood plank, angle iron square bar, wire and wiring material as per the IRS specification, non deteriorating type HRC fuses with bases, catenary wires, nuts and bolts and other items shall be supplied by the contractor. Relays, ARA terminalsonly shall be supplied by the Railways. Inspection: Site Engineer | — | — | — | 37,011.3 | |
| — | 5000.00 | — | — | ||
| Supply of ARA Terminal Block 25MM center M6 terminal made of PBT as per IRS spec. No.IRS-S75/2006 (Rev.2) & IRS drawing No. SA23741A(Alt.4), SA23745(Alt.5) ,SA-23746 & SA23756(Alt.3) .Inspection :RDSO | — | — | — | 3,62,850 | |
| — | 5000.00 | — | — | ||
| Testing & meggering of all types of outdoor cables after its laying and termination on both ends under supervision of Railway representative. This also includes preparation of test report for core to core and core to earth on prescribed proforma for each core of the cable separately. This also include dressing and lacing of cable on both ends. Proforma for testing and material for lacing to be supplied by the contractor. Inspection: Site Engineer. | — | — | — | 74,250 | |
| — | 10.00 | — | — | ||
| — | — | — | 4,07,277 | ||
| — | Supply by | of Earth Tester or similar Offer Consignee. | per specification: Model: CET- 03 | ||
| — | 2.00 | — | — | ||
| Supply and testing of electronic Cable Route Locator/Tracer equipment capable of tracing electronic markers and different types of underground signalling/ electrical cables of suitable make:3M Dynatel Model-2273M-iD/C-scope/ Stanlay or similar.(1) Receiver seek tech line locator/Cable avoidance tool 01 No. .(2)Transmitter /Signal Generator complete with earth stake and connection leads.01 No. (3) Inductive signal clamp.01 No (4) Carry bag 01 No. Inspection by RITES. | — | — | — | 8,88,070.98 | |
| — | 60.00 | — | — | ||
| Supply of Portable digital auto range multi-meter Philips, Motwane, Fluke or Rishabh make Rish Max12 or similar capable to measure from (0.1mv/0.01ma) AC/DC upto 10Amp(AC/DC), 600V(AC/DC) and 0.1 ohms-40M ohms suitable for measurement of Freq., capacitance complete with Manual, leads, battery and holster etc. (Inspection: Consignee) | — | — | — | 5,16,685.2 | |
| — | 30.00 | — | — | ||
| Supply of Portable digital auto range multi-meter clamp type Philips, Motwani, Fluke or Rishabh make capable to measure from (0.1mv/0.01ma) AC/DC upto 50Amp(AC/DC), 600V(AC/DC) and 0.1 ohms- 40M ohms suitable for measurement of Freq., capacitance complete with Manual, leads, battery and holster etc. Inspection :Consignee | — | — | — | 2,67,855.3 | |
| — | 5.00 | — | — | ||
| Supply of cable fault locator for underground cable as per model no. Telscout TS- 90(Test signal output 1/2 Sine, Pulse width 5nsec to 2500 nsec, Max range:1500m, Filter cut off frequency :150 Khz (High Pass Filter), Gain :0 to 63db), Stanlay or similar branded make as per specification. Inspection: Rites | — | — | — | 17,73,539.5 | |
| — | 5.00 | — | — | ||
| Therma vision Camera Specification as Per RDSO SPECIFICATION No- TI/SPC/OHE/TIPS/1031 December or latest, 2013, CEM MAKE MODEL DT-9897 or better, Inspection: RITES. | — | — | — | 9,42,820 | |
| — | 10.00 | — | — | ||
| Supply of Megger 500V DC Philips or similar make. Inspection : Consignee | — | — | — | 42,587.2 | |
| — | 10.00 | — | — | ||
| Supply of Digital Insulation Tester(Megger) 100V,Motwani,Philips or equal to make. Inspection by- Consignee. | — | — | — | 62,598.7 | |
| — | 500.00 | — | — | ||
| Wiring of relays in existing PI/RRI and at LC Gates as per appd wiring diagrams and to suit Railway electrified area. All wiring material including resistances and condensers except cables/wires to be supplied by contractor (Supply of cables & wires covered separately). It also includes dressing, bunching, lacing and fixing of relay bases. (Inspection: Site Incharge) | — | — | — | 2,43,115 | |
| — | 50.00 | — | — | ||
| Fabricating, writing and fixing of description boards made of ply 6mm thick with white sunmica glued over its surface and 1"x1" wooden baton fitted all around on the rear and having aluminum angle size of 25.4mmx25.4mmx3.15mm on all four sides as per instruction of Engineer at site. All the materials to be supplied by contractor. Inspection :Site Engineer | — | — | — | 1,34,936.5 | |
| — | 600.00 | — | — | ||
| Supply of Track Lead Junction Box(TLJB) as per Drg.No.RST-11509 or TLJB latest made from FRP material including brass bolts and hylam board sheet with terminals etc. The technical specifications are as follows: (a) TLJB complete with cover to be in black/red having approximate weight of 4.0 Kg with L-262mm W-212mm and H 90mm and all the holes required for mounting on FRP stump (vertical two for each FRP angle) HDPE pipe , cable etc. (b) Each TLJB shall have two TLJB bakellite terminal block fitted horizontally : each bakellite terminal block shall have two nickel chrome plate M10 brass terminal, 50mmlong.Alongwith each TLJB , nickel TLJB chrome plated brass links(two nos.0fadequate strength for vertical linking of the terminals to be supplied. (c)HDPE pipe of size 32/35mm , 380 mm long along with two nuts for fixing on the TLJB hole. (d) The FRP stump for TLJB mounting the TLJB to be made of one TLJB meter long 30mm X30mmX 4mm angle (2 nos.) and 300mm long 30mmX30mmX 4mm angle (1 no.) fixed at 50mm from the bottom using galvanized nuts and bolts. The TLJB and the angles TLJB for stump should come along with holes on them for fixing using galvanized nuts and bolts of adequate strength to be supplied along with TLJB drawing TLJB no. 11509. Inspection: RITES. | — | — | — | 10,89,954 | |
| — | 10.00 | — | — | ||
| Installation of Berthing and straight DC track circuits to suit RE area as per std. Practice. This will include following as per site requirement: - (a) Drilling of holes 7.2 mm dia or size as required provision of continuous G.I. wire bonding on switch portion and crossing of point with two bonds wires and two clips duly fastened with fish plates and bolts at each joints including transverse bonding with rope wire. 8 SWG G.I. soft bond wire, Channel bond pins and all other material required will be supplied by contractor. (b) Jumpering from rail to rail or to track lead junction box including polarity jumpers/cables as per track jumpering/ insulation diagram. This includes continuity of joint on rail web for TLJB/BOOTLEG bonding method, terminating the jumpers in the TL JB and fixing the jumper on the sleeper as per instructions of Engr. at site. (c) Fixing of insulated block joints complete with provision of skimmed fish plate. Fish plates shall be supplied by the Railways but skimming to be done by contractor. Supply of insulation materials for insulated block joints is not included. (d) Fixing of TL JBs as per drg. No.(NR/S&T/CON/3.2/97A) along with concrete foundation and plastering on both ends i.e. T.F. and TR end and for polarity changers as per the track jumpering/ insulation diagram. All material for fixing including angle iron shall be supplied by the contractor. This also includes supply and fixing of TLJBs will provision of M-6 terminals. TLJB to be written with track circuit number. (e) Prov. and wiring in the app. Cases/relay huts of T.F. battery charger, TF resistance 15 Ohms, track relays, choke B type (at Feed End & Relay End) & batteries as per the standard practice using fuses and terminals. This all include supply of all material by contractor except supply of TF battery charger, batteries, relays which are covered separately. (f) Commissioning of track circuits as per prov.of para of IRS specn. S36/87 Amd 2. This includes adjustment of track feed resistance, testing with train shunt resistance. This also includes preparation of track history cards. Track history card should be supplied by the Contractor. Inspection : RDSO (for Track feed Resistance and B type choke). | — | — | — | 1,51,833.3 | |
| — | 10.00 | — | — | ||
| Installation of Point track circuit having single point (excluding traps) DC track circuits to suit RE area as per std. Practice. This will include following as per site requirement:- (a) Drilling of holes 7.2 mm dia or size as required provision of continuous G.I. wire bonding on switch portion and crossing of point with two bonds wires and two clips duly fastended with fish plates and bolts at each joints including transverse bonding with rope wire. 8 SWG G.I. soft bond wire, Channel bond pins and all other material required will be supplied by contractor. (b) Jumpering from rail to rail or to track lead junction box including polarity jumpers/cables as per track jumpering/ insulation diagram. This includes continuity of joint on rail web for TLJB/BOOTLEG bonding method, terminating the jumpers in the TLJB and fixing the jumper on the sleeper as per instructions of Engr. at site. (c) Fixing of insulated block joints complete with provision of skimmed fish plate. Fish plates shall be supplied by the Railways but skimming to be done by contractor. Supply of insulation materials for insulated block joints is not included.(d) Fixing of TL JBs as per drg. No. (NR/S&T/CON/3.2/97A) along with concrete foundation and plastering on both ends i.e. T.F. and TR end and for polarity changers as per the track jumpering/ insulation diagram. All material for fixing including angle iron shall be supplied by the contractor. This also includes supply and fixing of TLJBs will provision of M-6 terminals. TLJB to be written with track circuit number. (e) Prov. and wiring in the app. Cases/relay huts of T.F. battery charger, TF resistance 15 Ohms, track relays, choke B type (at Feed End & Relay End) & batteries as per the standard practice using fuses and terminals. This all include supply of all material by contractor except supply of TF battery charger, batteries, relays which are covered separately.(f) Commissioning of track circuits as per pro v.of para of IRS specn. S36/87 Amd 2. This includes adjustment of track feed resistance, testing with train shunt resistance. This also includes preparation of track history cards. Inspection: RDSO (for track feed resistance and B type choke) | — | — | — | 2,42,747.5 | |
| — | 20.00 | — | — | ||
| Supply of track feed batt. charger 110VAC/2-4-6 VDC / 10 Amps as per RDSO spec. no. IRS: 89/2013 (Amd 1) or latest from RDSO appd. Firm. Inspection: RDSO | — | — | — | 95,063.4 | |
| — | 10.00 | — | — | ||
| Supply of Colour light signal post 3.6mtr and ladder 3.5Mtr & bases as per tech. spec. IRS-S-6-81, Rev-3 or latest . Inspection: Consignee. | — | — | — | 1,87,104.2 | |
| — | 5.00 | — | — | ||
| Supply of Colour light signal post 4.6Mtr and ladder 4.5Mtr & bases as per tech. spec. IRS-S-6-81, Rev-3 or latest . Inspection: Consignee. | — | — | — | 1,05,404.65 | |
| — | 15.00 | — | — | ||
| Casting, concreting and curing of foundation for main signal of size (1041mmx1041mm)at bottom and (711mmx711mm) at top and 1750mm deep as per approved Drg. no. NR/S&T/CON/2.1/97 all material such as anchor bolts, cement, coarse sand aggregate to be supplied by contractor. Inspection: Site Engineer | — | — | — | 1,76,405.25 | |
| — | 10.00 | — | — | ||
| Supply of 2 Aspect colour light signal unit complete with-out holders, lamps, lenses and signal transformer as per RDSO Drg. No. SA-23003 A/M (Adv), Alt-9 or latest . Specification no. IRS:S-26/64 Rev 1 or latest. Inspection: Consignee. | — | — | — | 1,80,705.5 | |
| — | 5.00 | — | — | ||
| Supply of 3/4 Aspect colour light signal unit complete with-out holders, lamps, lenses and signal transformer as per RDSO Drg. No. SA-23001 A/M (Adv), Alt-9 or latest respectively. Specification no. IRS:S-26/64 Rev 1 or latest.Inspection: Consignee. | — | — | — | 1,16,305.7 | |
| — | 10.00 | — | — | ||
| Fixing of CLS surface base, bolting on the foundation. Erection of CLS post with signal unit on the top or on an off-set bracket and fitting ladder and guard to the post at the top. Concreting ladder base and embedded into the ground with supporting bracket in the middle, blanking of the ladder for a distance of 1 feet between the height 6' 9" and 7' 9" from the rail level by MS angle and MS sheet 6mm thick wherever required. This includes provision of wooden (SAL) cross arm 1 mtr x 1 mtr for CLS unit prior to the commissioning, fixing of LED aspect, current regulator and hoods of CLS unit, terminating cables, wiring the CLS unit and focusing the signal. Elevation & distance of foundation from track shall be in accordance with schedule of dimension for Indian Railways and as per NR practice. All items for the above Works except Signal unit, LED signal, Signal post, Base and Ladder shall be supplied by the contractor including but not limited to the following: i) "U" bolt for offset brackets, ii) Wooden cross arm 1 mtr. x 1 mtr., iii) MS angle and MS sheet for blanking of ladder, iv) Supply and fixing of signal number plate (retro reflective) with complete fittings as per standerd railway practice. v) Wire mesh guard, lock for unit if required, nuts, bolts etc for the following: (a) Installation, erection, wiring of 2 aspect color light signal. Inspection: Site Engineer. | — | — | — | 30,394.1 | |
| — | 5.00 | — | — | ||
| Fixing of CLS surface base, bolting on the foundation. Erection of CLS post with signal unit on the top or on an off-set bracket and fitting ladder and guard to the post at the top. Concreting ladder base and embedded into the ground with supporting bracket in the middle, blanking of the ladder for a distance of 1 feet between the height 6' 9" and 7' 9" from the rail level by MS angle and MS sheet 6mm thick wherever required. This includes provision of wooden (SAL) cross arm 1 mtr x 1 mtr for CLS unit prior to the commissioning, fixing of LED aspect, current regulator and hoods of CLS unit, terminating cables, wiring the CLS unit and focusing the signal. Elevation & distance of foundation from track shall be in accordance with schedule of dimension for Indian Railways and as per NR practice. All items for the above Works except Signal unit, LED signal, Signal post, Base and Ladder shall be supplied by the contractor including but not limited to the following: i) "U" bolt for offset brackets, ii) Wooden cross arm 1 mtr. x 1 mtr., iii) MS angle and MS sheet for blanking of ladder, iv) Supply and fixing of signal number plate (retro reflective) with complete fittings as per standerd railway practice. v) Wire mesh guard, lock for unit if required, nuts, bolts etc for the following: (a) Installation, erection, wiring of 3/4 aspect color light signal. Inspection: Site Engineer. | — | — | — | 23,864.3 | |
| — | 5.00 | — | — | ||
| Installation, erection and wiring of 2/3/4 aspect LED lit colour light signal including 1/2/3/4/5/6 way Jn. type/Stencil/Theatre type route indicator which also includes fixing of route indicator on the top of the signal post or on offset bracket including fixing of offset bracket, wiring the whole unit, focusing of signal & route indicators. All items for installation and erection (excluding unit junction type route indicator and offset bracket covered separately) to be supplied by the contractor. Wiring & other fixing material, 'U' bolts will also be supplied by the Contractor. Inspection: Site Engineer | — | — | — | 22,114.55 | |
| — | 5.00 | — | — | ||
| Supply of 1-way route indicator junction type as per drg. No. SA-23401 (adv.) or latest complete with hoods & offset bracket 5 1/2" as per . specn.no.IRSS-66/84 (Amd-1) or latest, drg.no. SA 23401(Adv), Alt.-2 or latest. Inspection: Consignee. | — | — | — | 1,29,048.45 | |
| — | 20.00 | — | — | ||
| Fabrication, Supply and fixing of retroreflective P/G/C/A markers with complete fittings as per approved Drg. No. NR/S&T/CON/6.2/97. All material required for the job such as MS sheet, MS angle. Nut and bolts will be supplied by the Contractor. The P and G markers shall be as per Drg. No.S 23456(Adv) & SA 23477(Adv) respectively. Inspection: Site Engineer | — | — | — | 16,853.2 | |
| — | 10.00 | — | — | ||
| Casting, concreting, curing of foundations of size (400mmx300mm) at surface and 1000mm deep and erection of retroreflective SLB/BSLB/SB/ calling on boards/stop dead boards/Goods Warning Board/Passenger Warning Board as per drg. No. NR/S&T/CON/7.4/97 & provisions of SEM. Supply of SLB/BSLB/SB/calling on boards as per approved Drg. No.SA-2373 or latest has to be done by the contractor. Inspection: Site Engineer | — | — | — | 1,06,273.8 | |
| — | 5.00 | — | — | ||
| Installation, erection and wiring of LED lit calling- on/dependent shunt signal /illuminated 'A' marker/ 'AG' marker/ 'F' markers on the same post below main signal on offset bracket. Which also includes fixing of stencil and hoods, wiring and focusing of the signal. Offset brackets, calling on signal/shunt signal complete will be supplied by Railways (Supply of calling on/shunt signal is covered separately, elsewhere in the schedule). U-bolt for offset bracket and wire and wiring material will be supplied by contractor. Inspection: Site Engineer | — | — | — | 5,350.55 | |
| — | 5.00 | — | — | ||
| Supply of shunt signal position light with lock, unit offset bracket 3.5" dia. without holders bulbs etc. to drg.no.SA 23840(adv) to SA 23848 (adv), spec no .IRS-S-23/88 Dependent post type. Inspection : Consignee. | — | — | — | 50,712.4 | |
| — | 5.00 | — | — | ||
| Casting, concreting and curing of foundations for shunt signal/ 'F' marker of size (855mmx855mm) at bottom and (711mmx711mm) at top and 750mm deep as per approved Drg. no. NR/S&T/CON/2- 1/97A. All material such as cement, coarse sand, aggregate & foundation bolts will be supplied by contractor. Inspection: Site Engineer | — | — | — | 21,300.6 | |
| — | 5.00 | — | — | ||
| Installation, erection and wiring of independent position light shunt signal/'F' marker. This includes fixing of shunt signal, surface base signal post, LED signal unit/ lenses, lamp hood and wiring of shunt unit and focusing the signal. All material such as wire, nut & bolt etc. will be supplied by the contractor. Inspection: Site Engineer | — | — | — | 6,713.35 | |
| — | 300.00 | — | — | ||
| Supply and installation signal number plates Retroreflective type as per SEM. (Inspection: Supply- Consignee, Installation- Site Incharge) | — | — | — | 1,74,891 | |
| — | 5.00 | — | — | ||
| Supply of shunt signal position light complete with lock, unit post and surface base mounting socket 90mm dia without holders bulbs etc. to drg.no.23840 adv. Or latest specs.no.IRS-S- 23/88 Independent post type. Inspection :RITES | — | — | — | 50,619.25 | |
| — | 20.00 | — | — | ||
| Supply and installation of earth electrodes as per std. practice. The item includes digging of pit in earth, 3 Mtrs. deep and fixing earth electrode pipe. Casting of cement concrete enclosures as per drg. No. (NR/S&T/CON/6.4/97). The soil treatment shall be done as per std. practice. The item includes provn. of mild steel flat of size 35mm x 6mm (as per IRSEM) and nut bolted connection of MS flat with earth electrode. The other end of mild steel flat to be connected to block instrument, cable sheath of power equipment, signal base, apparatus case, CT rack / relay racks, other equipments as per the instruction of Engr. at site & IRSEM. Earthing connection location to location shall be done through cable which shall be provided by Railway. Complete materials such as earth electrodes as per drg. No. (NR/S&T/CON/6. 3/97), cement, wiring material, nut bolt for connection & mild steel flat of size 35mm x 6mm or 210 sqm as per SEM etc. to be supplied by the contractor. Inspection: Consignee. | — | — | — | 61,408.2 | |
| — | 200.00 | — | — | ||
| Supply, Installation & Commissioning of maintenance free earth suitable kit as per RDSO Specification no. RDSO/SPN/197/2008 and Drg No.SDO/./E&B/001 dated:- 19.09.2008 and Drg No. RDSO/SDO/./E&B/002 dated:- 19.09.2008. Earthing kit consisting of earthing electrode of 17mm dia as 3m long -01 no 2 MEEB (300mmx25mmx6mm) -o1 no. 3. SEEB (150mmx25mmx6mm) -01 no 4. Earth enhancing compound - 30 kg (minimum). This includes:- Provisiion of earth connection from MEEB to S&T equipment i.e. cable sheath, apparatus case, BPAC, Axle counter, IPS, Data Logger etc. with PVC earth wire of size 25/35 sq.mm through copper lugs of suitable size PVC earth wire shall be supplied by contractor. Note: At certain locations, it may not be possible to acheive earth resistance of less than 1.0 ohm with one earth electrode /pit due to soil resistivity. In such cases, provision of loop earth consisting of more than one earth pit shall be done, for interconnection of two earth pits copper tape of size 25x2 sq.mm shall be provided by the contractor. The number of pits required shall be decided based on the resistance achieved for the earth pits already installed. The procedure mentioned above for one earth pit shall be repeated for other earth pits. The other earth so installed for the purpose of loop earthing arrangement shall be counted as seperate earth. Inspection : RDSO for supply portion, Execution: Site Engineer. | — | — | — | 51,74,574 | |
| — | 50.00 | — | — | ||
| General concrete work in cement, coarse sand and aggregate ratio 1:3:6, work scattered at different places for items not covered in above schedule and fine plastering of top will be done with cement sand ratio of 1:4 . Volume of foundation also includes volume of C.I. base, anchor bolts etc. Coarse sand, aggregate 25mm and cement to be supplied by contractor. Inspection : Site Engineer | — | — | — | 1,50,737.5 | |
| — | 75.00 | — | — | ||
| Earth work for excavation and refilling around location boxes, signals etc. where necessary including 50m lead and 1.5m lift by excavation. The earth shall be rammed including breaking of clods, levelling and dressing. The earth work around the location/junction boxes/signalls shall be up to the plaster level and for width sufficient for the maintainer to attend the box both from front & back side. Inspection : Site Engineer | — | — | — | 10,309.5 | |
| — | 200.00 | — | — | ||
| Fabrication, supply and fixing of cable marker as per RDSO drg. No. SDO/Cable Laying / 020, dated 31.10.11. The marker shall be fixed at various places of Cable route as per instruction of Engg. at site. Inspection: Consignee. | — | — | — | 2,73,504 | |
| — | 20.00 | — | — | ||
| Supply and installation of 24-40V/5ADC-DC convertor module suitable for IPS systems as per instruction of Site Incharge and RDSO spec No.RDSO/SPN/ 165/ 2012 ver.3.0 or latest. (Inspection: Supply- RDSO,Installation- Site Incharge) | — | — | — | 3,87,526.8 | |
| — | 80.00 | — | — | ||
| Supply of DC-DC Converter for existing IPS of rating 60-66V/5A as per Spec.No.RDSO/SPN/165/2012 with ver.03 or latest. (Inspection: Supply- RDSO,Installation- Site Incharge) | — | — | — | 19,11,600 | |
| — | 100000.00 | — | — | ||
| Loading, unloading and leading of released materials from site to the store of Consignee/Dy. CMM/SSB or any other store of Northern Railway. (Inspection: Site In charge) | — | — | — | 7,33,000 | |
| — | 8.00 | — | — | ||
| Supply of ESM furniture of Godrej or similar make consisting of the following :- 1. Executive revolving bearing series low back floating chair with normal arms cushioned Chair : 1No. 2. Executive Table size 72x36x30"" with 3 drawers one side, lockers cabinet on other side : 1No. 3. Visitor chair seat & back cushion with high density Foam with plastic PVC handle capsul type Flat pipe duly Painted black : 3Nos. 4. One Steel Almirah of size 48""x30""x17"" with lock and handle arrangement for record keeping at station. Inspection : Consignee. | — | — | — | 3,32,111.92 | |
| — | 20.00 | — | — | ||
| Supply of hand operated track drilling machine for bonding hole. Inspection: Consignee | — | — | — | 1,60,702.8 | |
| — | 5.00 | — | — | ||
| Supply of Sine Wave output Voltage inverter of 2.0KVA capacity with minimum 180 Minutes backup, with having battery capacity VAH:8640 with trolley stand. Inspection:Consignee. | — | — | — | 1,65,907.95 | |
| — | 5.00 | — | — | ||
| Supply of Self Regulating Type Battery Charger,230V AC/110V DC, Charger 50 Amps as per RDSO Specn.No.IRS:S-86/2000 (Amnd.4) or latest. Inspection: RDSO | — | — | — | 6,11,731.45 | |
| — | 5.00 | — | — | ||
| Supply of Office table, laminated top, size minimum 4 ft x 5 ft, make Godrej/Durian/Methodex/President or of similar reputed make. (Inspection by consignee | — | — | — | 64,146.5 | |
| — | 30.00 | — | — | ||
| Supply of Chair, superior quality, size 57D x 58W x 88H and seat height 45 mm, make CH-7 (Godrej)/Geeken make. (Inspection by consignee) | — | — | — | 91,569 | |
| — | 2000.00 | — | — | ||
| Lettering and Numbering of all S&T gears like Signals, Loc.Boxes, Pt. Machines, TLJBs, Block joints etc. Each item to be taken as one unit.Inspection: Consignee. | — | — | — | 1,78,440 | |
| — | 22.00 | — | — | ||
| Lettering and numbering of detail and description writing of particulars of terminations and equipment's on relay rack, relays, cable termination rack, battery and power equipment's IPS operating panel, axle counter etc. constituting entire system with contractor's own paint and writing material (Asian make paint to be used). This includes supply and fixing of Teflon strip 3 mm thick and 25 mm wide for each row of relays and cable termination. This works hall be done as per existing practice of the division. Inspection: Site Engineer. | — | — | — | 2,16,368.46 | |
| — | 326.00 | — | — | ||
| Lettering, numbering, description writing, termination particulars, equipment's name etc. inside location boxes. Inspection: Site Engineer. | — | — | — | 1,03,113.8 | |
| — | 5.00 | — | — | ||
| [Supply of managed SDH (STM-1 Add/Drop MUX land upgradeable to STM-4) fully wired for 2 X 63 MB and equipped for 21E1s and a Virtual Container (VC)-12 with STM-1(L1.1) aggregate interface including power supply, order wire, Ethernet card, sub rack, inbuilt DDF, installation material and all other accessories, manuals etc. as per TEC. Specification GR SDH 04/02, March 02 or with latest amendment. The contractor will supply all other accessories as mentioned in the labove said TEC Specifications and system will have provision of different redundancy cards as per the TEC Specifications. Note: It shall be possible to increase capacity from 21E1 to 63 E1s by adding / inserting tributary cards. This includes connecting all pig tails, optical patch cords etc. to the SDH equipment. This also includes connecting the SDH equipment with all cards to the 48V Bus including supply of wires land connectors. Termination of all E1s on DDF taking PVC cable over runway or a wall. At the terminal station, one port may be disabled if required as per instructions given by site lengineer incharge. | — | — | — | 10,83,373.25 | |
| — | 5.00 | — | — | ||
| Supply of 2 Mb Programmable Primary Digital drop insert multiplexer as per RDSO Specs. IRS ITC- 68/2004 (Amnd.1) or latest with conference facility and other stipulation to tender documents and fully wired for 30 channel lcomplete with power supply card, remote control, supervision facility and all other accessories, installation material, manuals etc. It should have facilities to accommodate data interface card in multi drop mode and should be able to support cards needed for video conferencing and ISDN. It shall support NMS installed at Test Room and may operate local/remote location of entire section. It also includes submission of all technical documents, manuals and supply of all miscellaneous items which will be required for final testing and lcommissioning of system. The above MUX should be equipped with following circuits: - i) 2 wire/ 4 wire E&M VF circuits ( minimum 16 nos ckts) il) Subscriber loop circuits ( minimum 4 nos ckts) iii) Exchange loop interface circuits (minimum 8 circuits ) iv) This also includes connecting all pigtails, optical patch cords etc to the SDH lequipments. This also includes connection of [SDH and primary MUX equipment with all interface cards to the 48V Bus including supply of wires and connectors termination of all evens lon DDF taking PVC cable over runway or a wall and termination of VF interface circuit to the Krone type. INSPECTION: RDSO FOR SUPPLY PORTION. | — | — | — | 12,31,177.35 | |
| — | 365.00 | — | — | ||
| Maintenance of Track Mounted Equipments like S&T fitting on turnouts including different activities during BCM/TTM/UNIMATE machine works as follows: Specially opening and refixing of DC Track circuit jumpers / Axle Counter transducers during different Engineering Works.Opening of DC Track circuit / Axle Counter transducers digging work from rail toTLJB / TMU/ Location is required to be done as per site requirement also after refixing of DC-Track circuit / Axle Counter transducers needs to be buried in proper depth. It includes drilling hole in rail as per site requirement. The team to be provided for this work should comprise of: Fitter -1 Nos., Blacksmith -1 Nos., Mason / Carpenter - 1 Nos. and Helpers - 5 Nos.also it includes any work of Electrical operated lifting barriers (EOLB) or sliding boom and earthing arrangement of Signalling gears. Any other work as per instruction of Railway Engineer. All T&P & jigs required to execute the work will be supplied by the contractor. (NOTE: THE UNIT FOR THIS ITEM MAY BE READ AS "PER DAY PER TEAM"). | — | — | — | 27,60,049.7 | |
| — | 20.00 | — | — | ||
| Supply, Installation, testing & commissioning of MAPLE 4C of equivalent 1U, 19 Inch rack mountable device consisting of four E1 ports and three slots and one populated with 2W/4W E&M supporting up to eight interfaces, Balance two slots empty, units shall support both 230V AC/48V DC power supply including 50 pin cable one No. for supporting both 2W/4W E & W, AC adopter one number. Make: Mro tek, Real time, Cygnus, Cisco or equivalent. Inspection: RITES for supply portion. | — | — | — | 20,30,026.8 | |
| — | 10.00 | — | — | ||
| Supply, installation, commissioning Heat and Smoke Multi sensor detector with automatically adjusts sensitivity levels without the need for operator intervention or programming sensitvity increase with heat varying and floating sensitvity from 0.5 to 4%/Ft and shall be plug in type facility and address through switch. The base should also be supplied as per RDSO/SPN/217/2018. ver 2.0 or latest. Inspection : RDSO for supply portion. | — | — | — | 57,616.4 | |
| — | 1.00 | — | — | ||
| Supply, Installation, commissioning of analogue addressable UL listed Fire alarm Control Panel with 80 character display with battery charger and battery, backup for 24 Hr. normal operation and 15 Min alarm operation addressable power supply and alphanumaric keypad for installation for the FAS panel and 1000 event recording facility without GSM interface module as per RDSO/SPN/217/2016. Ver. 1.0 or latest. Inspection: RDSO for supply portion. | — | — | — | 5,34,843.39 | |
| — | 40.00 | — | — | ||
| Supply of Insulation for 'L' type bracket for point fitting IRS type complete consisting of Insulation plate - 01 No. Ferrule - 02 Nos. Washers - 04Nos. (Material Nylon 66). Inspection : CONSIGNEE | — | — | — | 12,098.4 | |
| — | 80.00 | — | — | ||
| Supply of Insulation for 'P' bracket for point fitting IRS type complete consisting of Insulation plate - 01 No. Ferrule - 02 Nos. Washers - 04Nos. (Material Nylon 66). Inspection : CONSIGNEE | — | — | — | 61,015.2 | |
| — | 40.00 | — | — | ||
| Supply of William Stretcher Insulation Set (complete) as per RDSO/SPN/168/2005 with insulating bush and washer to suit point layout and conforming to RDSO Drg.No.T-10372 or latest, T- 10368 or latest andT-10371 or latest. 1.1 Insulation for Leading stretcher bars(BG) each set comprising of (a) Insulating plate for leading insulated stretcher bars BG as per RDSO Drg.No.T- 10384 - 2 Nos. (b)Insulating bushing for leading insulated stretcher bars for BG as per RDSO Drg.No.T-10535- 4 Nos. (c)Insulating Washer for insulated stretcher bar BG as per RDSO drg.No.T- 10371 - 6 Nos. 1.2 Insulation for following stretcher bars BG. Each set comprising of: (a) Insulating sideplate for insulated stretcher bars BG asper RDSO Drg.No.T-10367 - 3 No. (b)Insulating bushing for insulated stretcher bars BG as per RDSO Drg.No..T-10368 - 6 Nos. (c)Insulating washer for insulated stretcher bars BG as per RDSO Drg.No.T10371 - 12 Nos Inspection: Consignee. | — | — | — | 17,440 | |
| — | 200.00 | — | — | ||
| Supply of drill bit of size 9/32"(7.2/7.14mm) twist drill morseshank suitable for making holes inthe rails. Contractor should get theapproval of sample from railwayEngineer before supply. (Inspection-Consignee)Make-JK or similar. | — | — | — | 12,272 | |
| — | 100.00 | — | — | ||
| Supply of plastic cover for 2 aspect signal unit cover is opened from front side and bottom side and made of black polythene sheet of 100 micron thickness size 1200mmx460mmx205 mm on back side 75mm wide corner to corner diagonal cross mark of silver of 100 micron thickness to be provided to the up cover with signal unit suitable to nylon rope of 5 mm dia and 4 mtr length to be provided on front side and of 1.5 mtr length. Inspection: Consignee. | — | — | — | 6,678 | |
| — | 100.00 | — | — | ||
| Supply of plastic cover for 3 aspect signal unit cover is opened from front side and bottom side and made of black polythene sheet of 100 micron thickness size 1300 mmx460 mmx205 mm on back side 75mm wide corner to corner diagonal cross mark of silver of 100 micron thickness to be provided to the up cover with signal unit suitable to nylon rope of 5 mm dia and 4 mtr length to be provided on front side and of 1.5 mtr length at centre. Inspection: Consignee. | — | — | — | 7,906 | |
| — | 100.00 | — | — | ||
| Supply of plastic cover for 4 aspect signal unit cover is opened from front side and bottom side and made of black polythene sheet of 100 micron thickness size 1700mmx460mmx205 mm on back side 75mm wide corner to corner diagonal cross mark of silver of 100 micron thickness to be provided to the up cover with signal unit suitable to nylon rope of 5 mm dia and 4 mtr length to be provided on front side and of 1.5 mtr length at centre. Inspection: Consignee. | — | — | — | 9,555 | |
| — | 200.00 | — | — | ||
| Supply of Reflective Tape (Yellow): Highlighter-grade retroreflective tape is made of non-metallized polycarbonate microprismatic material, visible from 1,000 meters. It is highly durable and meets AIS 090 specified reflection values. The material will not deteriorate, ensures a clean application, and provides enduring protection against seepage and dirt. All materials must confirm compliance to AIS 090. Size: four feet width in roll. Inspection by Consignee. | — | — | — | 26,380 | |
| — | 75.00 | — | — | ||
| Fabrication, supply and fixing of scaffolding /cable carrier made of angle ironof Size 35mmX35mmX5mm and flat of size 25mmX3mm as per instructions of engineer at site.The space between two flats will be 25cm or less as per site requirements allthe fixing materials i.e nut, bolt washer, insulators, cement concrete etc will be supplied by the contractyor . This includes insulating flat strips, cleaning priming by Red oxide, painting by ISI mark paint.Inspection :Site Engineer | — | — | — | 38,372.25 | |
| — | 2.00 | — | — | ||
| Supply of 4-Wire DTMF base way station eqpt.consisting of the following : i) Supply of 4 wire way station equipment as per IRS - TC - 60 / 2007 oflatest complete with 4 wire control telephone as perIRS - TC - 38 / 97 with latest amendment suitableto work on 4/6 quads- ii) Supply of Battery charger/power supply unit 230VAC/12VDC withbattery back up of 12V/7AH as per IRS-TC- 72/97 orlatest-1 no. Inspection : RDSO | — | — | — | 17,001.94 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
splinstruction.pdf
ATTACHMENT
Tender-Doc1470_1.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .