SH M V SANKAR SE CWE
CWE NAVY VASCO
REPAIR AND MAINTENANCE OF HT VCB RMU TRANSFORMER LT HT CABLES LT PANELS INCLUDING CAPACITOR PANELS AND ALLIED WORKS AT SITE A UNDER GE SB KARWAR
2020_MES_325981_1
85230/E8
Open Tender
Civil Works
Item Rate
180 days
CWE NAVY VASCO
AS PER TENDER DOCUMENS
9 documents required · 9 mandatory
₹500
Yes
GE SB KARWAR
₹47,600
Yes
8 May 2020
17 Feb 2020
18 Mar 2020
17 Feb 2020
16 Mar 2020
2 Mar 2020
Amount
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth for laying/taking out cable and getting out in soft/loose soil all as specified and as directed.
Returning, filling in including spreading, leveling, watering and well ramming in layer not exceeding 25 cm in soft/loose soil all as specified and as directed.
Removing excavated material/soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point all as specified and as directed.
Taking down carefully old unserviceable UG cable of any size from the trenches/wall/pole and keeping aside for reuse and remove the unserviceable cable from site including removal of brick/PCC cable cover complete all as specified and as directed. Note :Excavation and earthwork shall be measured and paid separately.
Laying only in repairs including jointing, testing and commissioning of, PVC insulated, armoured, heavy duty, LT UG electric cable with aluminum conductor 1100 volt grade of size 3.5 core 35/50 sqmm including provision of new lugs, glands etc laid in trenches or fixed on wall/pole or drawn through conduit all as specified and as directed.
All as per item No 5 here in before, but of cross sectional area 70 Sqmm 3.5 core/ 95 sqmm 3.5
All as per item No 5 here in before, but of cross sectional area 120 Sqmm 3.5 core/150 Sqmm 3.5 core
All as per item No 5 here in before, but of cross sectional area 3.5 core 185 sqmm/ 3.5 core 240 sqmm
Notes for item Nos. 5,6,7 & 8 1. Cable shall be issued under Sch 'B' free for fixing/laying only. 2. The unit rate quoted shall be deemed to include the cost of providing new lugs, glands etc complete. 3. Excavation & earth work, sand cushioning and PCC cover for cable protection shall be measured & paid separately.
Laying only including jointing, testing and commissioning of serviceable , LT UG cable of following sizes obtained from item No 4 herein before and providing with new glands & lugs etc complete all as specified and as directed for the cable of size 3.5 core 35 sqmm/3.5 core 50 sqmm
All as per item No. 9 here in before, but of cross sectional area 3.5 core 70/95/120/150 Sqmm
All as per item No. 9 here in before, but of cross sectional area 3.5 core 185/240/400 Sqmm
Supply & laying in repair including testing of XLPE insulated, armoured, heavy duty, HT UG electric cable with stranded aluminum conductor 11 KV grade all as specified and as directed of following sizes:-
(a) 3 core 95 Sqmm
(b) 3 core 185 Sqmm
(c) 3 core 240 Sqmm
Laying only in repair including testing of serviceable, HT UG cable of following sizes obtained from item No 4 herein before all as specified and as directed.
(a) 3 core 95 Sqmm
(b) 3 core 185 Sqmm
(c) 3 core 240 Sqmm Notes for Item Nos 12 & 13 : 1. Serviceable cable obtained from Sl item No 4 shall be used. 2. Excavation and earth work, sand cushioning, PCC cover for cable protection shall be measured and paid separately.
Supply and lay un-reinforced pre-cast concrete cable cover, class LV, type 1, flat, size 250mm x 150mm x 40mm as cable protection covers complete all as specified and as directed.
Supply only un-reinforced pre-cast concrete cable cover, class LV, type 1, flat, size 250mm x 150mm x 40mm as cable protection covers obtained from Si Item No 4,complete all as specified and as directed.
Supply and lay un-reinforced pre-cast concrete cable cover, class HV, type 1, flat, size 300mm x 180mm x 40mm as cable protection covers complete all as specified and as directed.
Supply and spread dry river sand in trenches for cable cushioning all as specified in clause 19.75 of SSR Part-I. Note:- Punned thickness of sand only shall be measured & paid.
Taking down old U /S GI tubing light grade including fittings in trenches of following sizes :-
(a) 100 mm bore
(b) 80 mm bore
(c) 50 mm bore
Supply & Laying in repair GI tubing light grade with necessary fittings as in cable protection fixed on wall / floor including necessary clamps bolts and nuts complete all as specified and as directed of following sizes :-
(a) 100mm bore
(b) 80mm bore
(c) 50mm bore
Material & Labour for straight through heat shrunkable joints (epoxy) size for underground cable including joint kits & labour complete for making joints suitable for LT PVC / XLPE insulated armoured heavy duty aluminium stranded complete all as specified and as directed of following sizes.
(a) 3.5 / 4 core 25 to 50 sqmm. Cat No .EPKJ 0130 or equivalent as mentioned in Appendix 'B'
(b) 3.5 / 4 core 70 to 150 sqmm. Cat No .EPKJ 0137 or equivalent as mentioned in Appendix 'B'
(c) 3.5 Core 185 to 300 sqmm. Cat No EPKJ 0144 or equivalent as mentioned in Appendix 'B'
Supply, Jointing & testing Indoor end termination type heat shrunkable 11 KV HT joint kit suitable for PVC / XLPE insulated stranded aluminium conductor of size 3core 95 Sqmm all as specified and as directed.
Supply, Jointing & testing Indoor end termination type heat shrunkable 11 KV HT joint kit suitable for PVC / XLPE insulated stranded aluminium conductor of size 3core 240 Sqmm all as specified and as directed.
Supply, Jointing & testing straight through type heat shrunkable 11 KV HT joint kit suitable for 3 core 95 Sqmm PVC / XLPE insulated stranded aluminium conductor all as specified and as directed.
Supply, Jointing & testing straight through type heat shrunkable 11 KV HT joint kit suitable for 3 core 185 Sqmm PVC / XLPE insulated stranded aluminium conductor all as specified and as directed.
Supply, Jointing & testing straight through type heat shrunkable 11 KV HT joint kit suitable for 3 core 240 Sqmm to 400 Sqmm PVC / XLPE insulated stranded aluminium conductor all as specified and as directed.
S&F Danger notice plate of 1.6 mm thick mild steel sheet vitreous enamelled white, with letters, figures & conventional skull & bones in signal red colour and fixed with MS clamps, bolts and nuts of approved size, for HT 20x25 cm size all as specified & as directed.
All as per Item No 26 here in before, but for LT 20 X 15 cm size
Testing of HT UG cable by checking the insulation resistance using 5000v x 10000v fault insulation locator tester, identify any number of cable fault in a single stretch (from source to load) having minimum length upto 1500 RM and pin point the fault location complete all as specified & as directed. Note: In single stretch having minimum length 1500 RM whatsoever Nos of fault shall be paid as each job
Testing of HT UG cable by checking the insulation resistance using 5000v x 10000v fault insulation locator tester, identify any number of cable fault in a single stretch (from source to load) having length more than 1500 RM and pin point the fault location complete all as specified & as directed. Note:In single stretch having length more than 1500 RM whatsoever Nos of fault shall be paid as each job
Testing of LT UG cable by checking the insulation resistance using 5000v x 10000v fault insulation locator tester, identify any number of cable fault in a single stretch (from source to load) and pin point the fault location complete all as specified & as directed for length upto 1500 m . Note: In single stretch any Nos of fault shall be paid as each job.
Testing of LT UG cable by checking the insulation resistance using 5000v x 10000v fault insulation locator tester, identify any number of cable fault in a single stretch (from source to load) and pin point the fault location complete all as specified & as directed for length more than 1500 m. Note : In single stretch any Nos of fault shall be paid as each job
Cutting & removing the existing rusted & pitted hinges of panel board door using gas cutter, Supply & weld new hinges of matching type & size to the existing one all as specified & as directed.
S&F in repairs of existing rusted panel board doors with new panel doors made out of 2.6 mm (12 Gauge) thick CRCA sheet all as specified & as directed.
S&F in repairs of wornout panel door rubber gasket including pasting & aligning properly all as specified and as directed.
S&F in repairs panel door locks heavy duty allen key operated suitable to match the existing one including taking down the existing defective one all as specified and as directed.
S&F in repairs MCCB 400 Amps 4 pole 50 KA breaking capacity,415 Volt ,50 Hz with thermal magnetic release all as per all as specified and as directed. Make : L&T Cat No. CM98404OORO or equivalent as mentioned in Appendix ‘B’.
S&F in repairs MCCB 250 Amps 4 pole 25 KA breaking capacity,415 Volt ,50 Hz with thermal magnetic release all as per all as specified and directed. Make : L&T Cat No. CM90634OOPO or equivalent as mentioned in Appendix ‘B’.
S&F in repairs MCCB 125-160 Amps 4 pole 25 KA breaking capacity,415 Volt ,50 Hz with thermal magnetic release all as per all as specified and directed. Make : L&T Cat No. CM90634OOMO or equivalent as mentioned in Appendix ‘B’.
S&F in repairs MCCB 100 Amps 4 pole 25 KA breaking capacity,415 Volt ,50 Hz with thermal magnetic release all as per all as specified and directed. Make : L&T Cat No. CM90634OOPO or equivalent as mentioned in Appendix ‘B’.
Supply & Fix in repairs HRC fuses of HN type of 100 Amps rated at 415 AC with breaking capacity of 80 KA all as specified and directed . Make : L&T Model No. SF94029 or equivalent as approved by GE.
Supply & Fix in repairs HRC fuses of HN type of 125 Amps rated at 415 AC with breaking capacity of 80 KA all as specified and directed . Make : L&T Model No. SF94029 or equivalent as approved by GE.
Supply & Fix in repairs Tinned aluminium lugs suitable for LT cable of following sizes :- Make : Dowells or equivalent as approve by GE.
(a) 16 Sqmm
(b) 25 Sqmm
(c) 35 Sqmm
(d) 50 Sqmm
(e)70 Sq mm
(f) 95 Sqmm
(g) 120 Sq mm
(h) 150 Sqmm
(j) 185 Sqmm
(k) 240 Sq mm
M&L for two coats of cement based paint of approved colour including preparation of surface pedestals of outdoor type LT panels all as specified and as directed.
M&L for painting of steel surfaces of panel board with one coat of smoke grey synthetic enamel paint over the existing surface using spray gun including making surface by cleaning/ removing dust, duet etc before painting all as specified and as directed.
All as per item No 44 above but with two coats of smoke grey synthetic enamel paint over a coat of primer on new steel surfaces of panel board all as specified and as directed.
M & L for writing letters or figures (Block / Roman ) in English to mark incoming / outgoing cables / power supply locations etc., on painted panel boards, in black colour with enamel paint of size all as specified & as directed.
M&L for isolating earthing lead conductor from test point and measuring resistance value of earth pits transformer,panels etc after testing , report shall be furnished to Engineer-in Charge in standard format approved by Engineer-in Charge.
Servicing of 11 KV Vaccum Circuit Breaker (VCB) by drawing out circuit breaker mechanism, cleaning thoroughly inside and outside lubricating the mechanism adjusting the required various mechanism settings, checking and lubricating the various interlocks, checking the breakers operations, checking the healthiness of pole by meggaring , lubricating racking mechanism, checking the operation of various limit switches checking the operation of the breaker and the racking mechanism, testing the unit on no load complete all as specified and as directed.
M&L for attending emergency breakdown for 11 KV VCB any capacity as and when ordered by Engineer-in-Charge, including servicing, adjusting and fault finding and rectifying the fault by qualified Engineer and testing the unit complete and submitting the test report all as specified and as directed.
Notes for item Nos 48 and 49 (a) Servicing of breakers to be carried out by qualified Engineer. The servicing of breaker shall include the followings :- (i) Inspection and cleaning to be carried out by qualified Engineer. (ii) Operation of door interlock, interlocking plate and shutter operation inside of panel. (iii) Check the Mechanical ON-OFF function, electrical and mechanical operation and damage part of VCB. (iv) Regrasing and oiling of breaker mech, adjustment of various mechanism setting as required, checking contact tightness, contact erosion pins, mannually vaccum check of VCB. (v) Racking-Rack out operation in test and service position of VCB troolly.
(vi) Megger Test (IR Value -1 KV/2.5 KV) E-RYB, RY-YB-BR-R'R, Y'Y,B'B. (vii) CRM Test (Contact resistance ) of Vaccum interrupter R,Y,B in on condition outside of panel. (viii) Time test of contact pole by test kit (in mile second). (ix) Function of closing coil, trip coil, spring charging motor, auxilary contact , limit switches etc. (x) Checking and lubricating of various interlocks. (xi) Submission of test report in standard format of vaccum circuit breaker.
(b) Tools and testing instruments required for servicing of VCB shall be arranged by the contractor. (c) The unit rate quoted shall be deemed to be include the cost of grease, lubricating material, cleaning material service and list of spares required for preventive /breakdown maintenance. (d) After servicing, report shall be furnished to Engineer-in-Charge in standard format approved by Engineer-in-Charge. (e) List of spare parts required for preventive maintenance /emergency breakdowns shall be submitted to Engineer -in-Charge after Ist inspection.
S&F in repairs of space heaters with thermostate with setting 0-80c at HT 11 KV VCB Panel all as specified and as directed.
Servicing of dry cast Transformer 1600KVA , 11 KV/433V by disconnecting incoming & outgoing power supply, opening up, cleaning the transformer internally & externally inspecting all the metering equipments, tightening all electrical connections checking & recording insulation resistance on both LT & HT sides, checking & recording earth resistance complete through authorised service engineer of OEM all as specified & as directed. Location : DSS-1/ DSS-1A/ DSS4/ DSS-4A/ DSS-6/ DSS-8/ DSS-9
Servicing of oil cooled Transformer 500 KVA , 11 KV/433V by disconnecting incoming & outgoing power supply, opening up, cleaning the transformer internally & externally inspecting all the metering equipments, tightening all electrical connections checking & recording insulation resistance on both LT & HT sides, checking & recording earth resistance complete through authorised service engineer of OEM all as specified & as directed. Location : DSS-10 at corritop
Servicing of oil cooled Transformer 630 KVA , 11 KV/433V by disconnecting incoming & outgoing power supply, opening up, cleaning the transformer internally & externally inspecting all the metering equipments, tightening all electrical connections checking & recording insulation resistance on both LT & HT sides, checking & recording earth resistance complete through authorised service engineer of OEM all as specified & as directed. Location : DSS-11 ( Near Map quarters)
Taking out ACB of L&T make, of capacity 12KV, 800 Amp rating Air Break indoor load break switch from its sub cubicle and carrying out routine maintenance as per manufacturer maintenance manual, examine the moving isolating contacts for any discolouration, cluster contacts, remove the arc chutes, check the SMC moulding are intacts, examine the moving contacts main contacts silver tips, spring mechanism, clean all contacts with a suitable solvent and contacts regreased with HP multipurpose grease, all contacts setting checked, readjusted if required, and regreased with HP multipurpose grease, all tripping device like manual trip, undervoltage, shunt trip release, over current and earth fault tripping device to be tested, readjusted and confirm all tripping device is in healthy condition, check and record IR value of ACB, with 1.1. KV LT megger calibrating ground fault / short ckt, overload relays for tripping & timing complete and rendering test report all as specified and as directed. Location : DSS-1, DSS-1A, DSS4, DSS-4A, DSS (UC), DSS-6, DSS-8, DSS-9, DSS-10, DSS-11 (Map qtrs)
NOTES : (a) Rate is inclusive of fixing of spares if any required. (b) The scope of work includes following :- (aa) Inspection & cleaning the mechanism house (ac) Check the Mechanical ON-OFF function, electrical & mechanical operation and damage part of VCB. (ad) Re-greasing and oiling of breaker mech, adjustment of various mechanism setting as required, checking contact tightness, contact erosion pins, mannually vaccum check of ACB.
(af) Megger test (IR value - 1KV / 2.5KV) E-RYB, RY-YB, BR-R'R, Y'Y, B'B. (ag) CRM Test (contact resistance) of Vacuum Inteerupter R, Y, B in on conditionout side of panel. (aj) Function of closing coil, Trip coil, spring charging motor, auxiliary contact, limit switches etc. (ak) Checking & lubricationof varius interlocks. (al) Submission of test report in standard format of vacuum circuit breaker. (ii) Tools & testing instruments reqd for servicing of ACB will be arranged by the contractor. (iii) The unit rate quoted shall be deemed to include the cost of grease, lubricating material, cleaning material service & list of spares reqd for preventive / breakdown maint. (iv) After servicing, report will be furnished to Engr-in-Charge in standard format approved by Engr-in-Charge. (v) List of spare parts required for preventive maintenance / emergency breakdowns shall be submitted to Engineer-in-Charge
M & L for Calibration of all relay & meters by primary/ secondary injection current complete all as specified and as directed.
Supply and fixing in repair of Male Contact (Gattu) of 11 KV VCB HT Panel VD4 suitable for 800 Amps article No 590664-001 of OEM as per existing and size complete all as specified and as directed.
Supply and fixing in repair of tulip contact (Female) of 11 KV VCB HT Panel VD4 suitable for 800 Amps article No 587869-805 of OEM as per existing size complete all as specified and as directed.
Supply & Fixing in repairs Incoming spout bushing without contacts for 11 KV VCB breakers complete all as specified and as directed.
Supply & Fixing in repairs Outgoing spout bushing without contacts for 11 KV VCB breakers complete all as specified and as directed.
M & L for Calibration of Current Transformer by primary injection test complete all as specified and as directed.
M & L for circuit checking of panel wiring for its indicating and protection complete all as specified and as directed.
ANKIT SHIP REPAIRERS AND SUPPLIERS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .