| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.6 LAccepted-AOC 106 1 RAJA RAMMOHAN SARANI KOLKATA 700 009 | KOLKATA | WEST BENGAL | 700009 | L1 | Accepted-AOC Being L1 bidder. | |
| 2 | L2₹39.5 L+₹10.9 L (38.0%)Rejected-Finance | L2 | Rejected-Finance Rejected due to higher than L1 bidder. Amount considered after deduction of schedule of credit amount i.e. Rs. 56580.00 | |
| 3 | L3₹40.3 L+₹11.7 L (40.9%)Rejected-Finance | L3 | Rejected-Finance Rejected due to higher than L1 bidder. Amount considered after deduction of schedule of credit amount i.e. Rs. 56580.00 |
Tender Value
₹41.9 L
EMD Value
₹83,700
Closing Date
7 Dec 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE CENTRAL, KOLKATA
Garrison Engineer (Central) Kolkata, T-37, Napier Road, Hastings, Kolkata-700022
PROVN OF PVC DOOR IN BATHROOM TOILET OR ACCN IN VARIOUS BLDG AT STRANDLINE AND AL SLIDING WINDOW DOOR SHUTTER IN BALCONY AND COMMON PASSAGE FOR PROTECTION BLDG NO P1 AND SPL REP TO BDY WALL AND ADDN ALTN BLDG NO P174 AT AFCB AT HQ EAC UNDER GEC KOL
2020_MES_387269_3
8302
Open Tender
Miscellaneous Works
Item Rate
180 days
Kolkata
As per tender documents
9 documents required · 9 mandatory
₹500
GE CENTRAL KOLKATA
₹83,700
Yes
4 Jan 2021
20 Nov 2020
9 Dec 2020
20 Nov 2020
7 Dec 2020
25 Nov 2020
20 Nov 2020 - 24 Nov 2020
60 days
Amount
Taking down cement plaster on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water complete all as specified and directed
Taking down chowkats or frame, n.exc 1.5 Sqm each with shutters (without taking off shutter from the frame) complete all as specified and directed.
Demolition of plain cement concrete (reinforced) of any description and in any position complete all as specified and directed.
Demolition of plain cement concrete (unreinforced) in ground floors and pavings not exceeding 15 Cm thickness. (below or above ground level) complete all as specified and directed.
Demolition of brick work / stone masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and as directed.
Taking down cement plaster on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water complete all as specified and directed
Dismantling wrought iron or mild steel work of any description not otherwise specifically provided for complete all as specified and directed.
Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation etc. or for shafts, well , cesspits,manholes,pier holes etc. not exc 10 Sqm on plan and getting out in soft / loose soil. complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 Cm as in soft / loose soil complete all as specified and directed.
Removing excavated material of soft / loose soil not exc. 50 m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and directed.
Supply and laying dry coarse sand as in cushioning of under ground electric cable in trenches, laid to a uniform thickness of 23 Cm (15 Cm under the cable & 8 Cm over the cable) and gently punned down to 18 Cm thickness complete all as specified and as directed by the Engr-in-Charge. Note:- Thickness after punning down shall be measured for payment.
Supply and laying in trenches Bricks, sub class 'B' over burnt (kiln burnt) old size bricks, laid flat dry with width of the bricks laid to the axis of the cable for protection of cable complete all as specified and as directed by the Engr-in-Charge.
Laying only in trenches Old serviceable bricks obtained from taking out old unserviceable XLPE cable, laid flat dry with width of the bricks laid to the axis of the cable for protection of cable complete all as specified and as directed by the Engr-in-Charge.
Material and Labour for hardcore of gauge n.exc 63 mm of broken stone or boulders, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
Material and Labour Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed.
Material and Labour Reinforced cemnt concrete type A1 ( 1:1.5:3, using 20mm graded crushed stone aggregates) as in slabs, beam, cantilevers, lintel over 1.5m span etc complete all as specified and as directed.
Material and Labour Reinforced cemnt concrete type A1 ( 1:1.5:3, using 20mm graded crushed stone aggregates) as in chajja, slaba and shelves and like etc complete all as specified and as directed.
Material and Labour for Plain cement concrete 1:4:8, type D-2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed.
Material and Labour for Plain cement concrete 1:3:6, type C-2 (using 40 mm graded stone aggregate) as in foundation , filling and mass concrete etc complete all as specified and directed.
Material and Labour for Plain cement concrete 1:2:4, type B-0, (using 12.5 mm graded stone aggregate) as in coping of bed block for fencing posts including weathering, slightly rounded or chamfered angles and throating including necessary formwork and finishing the surfaces complete all as specified and as direcetd.
Material and Labour for Plain cement concrete 1:2:4, type B-0, (using 12.5 mm graded stone aggregate) 25mm thick as in damp proof course including mixing water proofing compound @ 2% by the weight of cement complete all as specified and as direcetd.
"Supply only" liquid water proofing compound (ISI marked) complete all as specified and directed. Make:- STP NO 1/ PEDILITE(DR FIXIT)/ FOSROC/ CICO/ SIKA
Materials and Labour Use and waste Formwork to edges of concrete flats, breaks in floors, openings in concrete walls, floors and roofs and sides of RCC/PCC bands in walls, horizontal or sloping, and similar work all exceeding 20cm wide. (Where RCC/PCC band in walls, spanning and opening complete all as specified and as directed.
Materials and Labour Use and waste Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide for rough finished surface of concrete complete all as specified and as directed.
Material and Labour Brick work with fly ash bricks of designation 7.5, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 complete all as specified and directeded.
Supply and fix 4mm thick E-board classic any design plain of size 595 x 595 mm fixed as in ceiling over aluminium grid suspended with GI hooks 6mm dia and clamp to hold GI pipe of the following section :- a) 25 x 25 x 1.5mm(Minimum thick) aluminium angle b) 25 x 25 x 1.5mm (Minimum thick) aluminium cross Tee. c) 25 x 35 x 1.5mm (Minimum thick) aluminium main Tee , including applying two coats of acrylic emulsion distemper after preparation of surface complete all as specified and directed by Engr-in-Charge.
Supply and fix TMT steel bars 10mm dia., and over cut to length, bend to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality complete all as specified and directed.
Supply and fix TMT steel bars 5 to 8mm dia, cut to length as in stirrups, spacers and binders bend to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality complete all as specified and directed.
Supply and Fix Mild steel work as Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc conforming to Fe-410W(GdeE-250) qualityB complete all as specified and as directed.
Supply and Fix Mild steel work as in angle iron posts and struts in fencing including setting and benching to shape required, drilling holes, notching for wire and fixed in position conforming to Fe-410-0 complete all as specified and as directed.
Supply and fix Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured) complete all as specified and as direcetd.
Supply and fix Pre painted Concentrina coil, punched tape manufactured from 2.24mm dia high tensile spring steel wire, dia of each concentrina being @ 610mm and the height of coil when stretched shall be approximately 500mm duly tied to the barbed wire with and including provision of steel clips @ 5 clips ibn one row complete with Zink coating and as directed by Engineer-in-Charge.
Supply and fix Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
Supply and fix factory made solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube complete all as specified & directed by the Engr-in-Charge.
S & F factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded, plain colour PVC 'C' channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement, as per specification and drawing and as directed.
Supply and fix aluminium anodised three track sliding window frame with shutters ( two panels of glazed shutter and one panel of wire mesh shutter) including all necessary joining cleats, hold fast, rubber gasket, snap beading and locking arrangements etc. complete and glazing with 5 mm thick tinted glass to aluminium frame work using rubber gasket and stainless steel wi\re cloth of 0.36mm nominal dia of wire fitted with screws and washer. The section of frame and shutter is as under complete all as specified and as directed:- (A) Sections for frame (i) Top and verticals 92x 29.50 x 1.30 mm thick (ii) Bottom 92 x 29.50 x 1.20 mm thick. (B) Sections for shutter (i) 'A' section 39 x 20 x 1.50 mm thick (ii) 'Interlock' section 39 x 20 x 1.50 mm thick (iii) 'H' section 41 x 20 x 1.10 mm thick .
Supply and fix aluminium anodized ( Powder coated) four track sliding window shutters with frame including all necessary jointing cleats, holdfasts, , rubber gasket, snap beading and locking arrangements fixed with with screws to wall etc complete and glazing with and including 5mm thick tinted glass to aluminium frame work using rubber gasket and including stainless steel wire cloth of 0.36mm dia & average width of aperture 1.40mm with staple or suitable fillets and wire mesh fitted with screws and washers etc with the following section of frame and shutter Complete all as specified and as directed. (A) Section for shutters:- (i) 'H' Section 39mm x 20mm x 1.50mm thick. (ii) Interlocking section 39mm x20mm x1.50mm tthick. (iii) Edge and bottom section 41mm x 20mm x 1.50mm thick. (B) Section of frame:- (i) Top and side of section 123mm x29.70mm x1.50mm thick not less than 1.30Kg/Rm. (ii) Bottom section 123mm x29.70mm x1.50mm thick not less than 1.502 Kg / Rm complete all as specified and as directed by Enginner in Charge. Note:- Cost of 5mm thick tinted glass and cost of wire gauge shall deemed to be included in the rate quoted by Tenderer.
Suplly and fixing Exterior Aluminium composit panel ( ACP) of any shade/ colour, thickness of panel shall be 3mm thick of ISO 9001-2008 certified including aluminium frame work of rectangular section 63.5mm x 38.10mm x1.50mm thick for back support frame for installing ACP panel in hollow space between coloumns / wall etc. The Joints betwen ACP will be filled with backer rod and sealed with silicon weather seal complete all as specified and directed by engineer-in-Charge. Note:- Aludecor Lamination Pvt.Ltd / Pratabond / Hex Bond ACP / Alstrong.
Supply and fix 100mm butt hinges Stainless steel complete all as specified and as directed.
Supply and fix 100mm butt hinges mild steel, medium weight, cold rolled complete all as specified and as directed.
Supply and fix 150mm Aluminium anodized barrel tower bolts of extruded section complete all as specified and as directed.
Supply and fix 150 mm extruded aluminium alloy handles, fabricated type, anodized complete all as specified and as directed.
Supply and Fix 300mm aluminium, anodised sliding door bolt with hasp, staple(bolt type) and fixing clip of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy complete all as specified and as directed.
Material and Labour for 100 mm thick, plain cement concrete 1:3:6, type C-2 (using 40 mm graded stone aggregate) as in sub-base of flooring, etc complete all as specified and directed.
Material and Labour for 25 mm thick, plain cement concrete 1:2:4, type B0 (using 12.5 mm graded stone aggregate) as flooring, etc complete all as specified and directed.
Material and Labour for 75 mm thick, plain cement concrete 1:3:6, type C-2 (using 40mm graded stone aggregate) as in plinth proction or pavings etc finishing cement concrete surface even and fiar without using extra cement complete all as specified and directed.
Material and Labour 25mm thick Pre polished coloured cement concrete chequerred tiles of size 400X400 mm jointed and pointed in neat cement slurry with white or coloured to match including over 20 mm thick screed bed CM 1:4 complete all as specified and directed.
Materials and labour for non-skid, ceramic, coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exc 0.11 Sqm but n.exc 0.18 Sqm, in floors etc,set and jointed in neat cement slurry and jointed in white or coloured cement to matcht as on vertical surfaces such as skirtings, dados, risers etc over 10mm thick backing course in CM 1:4 complete all as specified and directed.
Materials and labour Glazed ceramic colour tiles in vertical surfaces such as skirtings, dados, risers etc of size 450 x 300 x 7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement ot match the tiles over and including 10mm thick backing course in CM 1:4 for receiving tiles.
Material and Labour Rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 and finished the surfaces even and smooth without using extra cement complete all as specified and directed.
Material and Labour Rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 and finished the surfaces even and smooth without using extra cement complete all as specified and directed.
Material and Labour Rendering 15 mm thick on other than fair faces of brick work or concrete surfaces in cement mortar 1:4 and finished the surfaces even and smooth without using extra cement complete all as specified and directed.
Material and Labour Preparation of new steel surfaces of any description, over 10 Cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint of any colour / tint over a coat of red oxide primer complete all as specified and directed.
Material and Labour Preparation of new wooden surfaces of any description, over 10 Cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint of any colour / tint over a coat of pink primer complete all as specified and directed.
Material and Labour Preparation of old steel surfaces of any description, over 10 Cm in width or girth, not otherwise described and applying one coat of synthetic enamel paint of any clour / tint complete all as specified and directed.
Materials and labour Preparation of newly plastered wall surfaces of any description and applying two coats of cement base paint of any colour / tint over a coat of primer at any height with safety measure complete all as specified and directed.
Materials and labour Preparation of newly plastered wall surfaces of any description and applying two coats of Exterior emulsion paint ( Weather Coat) of any colour / tint over a coat of primer complete all as specified and directed.
Materials and labour Preparation of old plastered wall surfaces of any description and applying two coats of cement base paint of any colour / tint at any height with safety measure complete all as specified and directed.
Materials and labour Preparation of newly plastered wall surfaces of any description and applying two coats of acrylic distemper of any colour / tint over a coat of primer complete all as specified and directed.
Materials and labour Preparation of old plastered wall surfaces and applying one coat of acrylic distemper of any colour / tint complete all as specified and directed.
Material and labour for Concealed Point wiring with PVC insulated and unsheathed FR cable single core multistranded copper conductor 1.5 sqmm size, 1100 volts grade cable conforming to IS - 694 1990 drawn through and including PVC non metallic rigid conduit 20mm dia, ISI marked with all accessories including fabricated MS terminal boxes fixed flush with wall surface with 3 mm thick plastic masonite laminated sheet top cover fixed with cadmium screw for mounting switches, sockets, regulator etc including 1.5 sq mm FR stranded PVC insulated and unsheathed copper conductor earth continuity conductor to common earth and connecting to earth dolly including cutting, chasing the surface and then making good the same in CM 1:3 all as specified for one light or fan point controlled by one switch single pole one way/ 3 pin 5 Amps Socket outlet point. Note: Red coloured cable shall be used for live connection, black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board, cost of conduit shall deemed to be included in the rate quoted.
All as per item No 69 here-in-before but for one 15/16 Amps switch socket outlet on independent board with 2.5 sqmm PVC (FR) insulated un-sheathed copper conductor cable multistranded conductor 1100 volts grade and 2.5 Sqmm copper conductor cable (FR) as earth continuity conductor complete as directed.
Supply and fix Ceiling rose surface Bakelite three terminals 230 volts complete all as specified and as directed.
Supply and Fix LED luminarie 36 watt recessed type full open 2'x2' uniform lumination with longer life and less maintenance and making connection with PVC cable of 0.50 Sqmm copper conductor complete including all accessories complete all as specified and as directed. Make:- Crompton / Syska/ Philips/ Havells/ Century LED/ Bajaj/C&S
Supply and Fix LED bulk head ftiings of capacity 10 watt wall mounted type with bulb complete including all accessories complete all as specified and as directed. Make:- Crompton / Syska/ Philips/ Havells/ Century LED/ Bajaj/C&S
Supply and fix Sheet metal enclosure Metal Door for DB's where MCBs to be used 8 way single pole and neutral with 200 amps rated bus bar complete all as specified and as directed. Make:- Legrand / Siemens/ ABB/ Schneider.
Supply and fix MCB 6 to 32 Amps, SP, 240 Volts , 'C' curve braking capacity 10 kA as directed by the Engr-in-Charge. Make:- Legrand / Siemens/ ABB/ Schneider.
Supply and fix MCB 6 to 32 Amps, DP, 240 Volts , 'C' curve braking capacity 10 kA as directed by the Engr-in-Charge. Make:- Legrand / Siemens/ ABB/ Schneider.
Supply and fix Ceiling fan 1200mm sweep, 230 Volts, 50 Hz, single phase including fixing of 'S' hook on roof with clamp complete all as specified and as directed. Make:- Crompton / Havells / Usha/ Bajaj.
Supply & fix Modular type switch 6 Amps 230V AC single module one way complete all as specified and as directed. Make:-Legrand / ABB / Crabtree.
Supply & fix Modular type switch 16 Amps 230V AC single module one way complete all as specified and as directed. Make:-Legrand / ABB / Crabtree.
Supply & fix Modular type White cover plate with frame, 1 module complete all as specified and as directed. Make:-Legrand / ABB / Crabtree.
Supply & fix Modular type White cover plate with frame, 3 module complete all as specified and as directed. Make:-Legrand / ABB / Crabtree.
Supply & fix Modular type White cover plate with frame, 12 module complete all as specified and as directed. Make:-Legrand / ABB / Crabtree.
Supply & fix Modular type socket, 6 Amps, 2/3 pin combined 2 module complete all as specified and as directed. Make:-Legrand / ABB / Crabtree.
Supply & fix Modular type socket, 6/16 Amps, 2/3 pin combined 2 module complete all as specified and as directed. Make:-Legrand / ABB / Crabtree.
Supply & fix Modular type step type fan regulator, 120W, 2 module complete all as specified and as directed. Make:-Legrand / ABB / Crabtree.
Supply & fix Sunken flush metal GI boxes for fixing of modular switches/sockets flush to the walls, 1 Module/ 2 Module complete all as specified and as directed. Make:-Legrand / ABB / Crabtree/ Anchor/ Havells
Supply & fix Sunken flush metal GI boxes for fixing of modular switches/sockets flush to the walls, 3 Module complete all as specified and as directed. Make:-Legrand / ABB / Crabtree/ Anchor/ Havells
Supply & fix Sunken flush metal GI boxes for fixing of modular switches/sockets flush to the walls, 12 Module complete all as specified and as directed. Make:-Legrand / ABB / Crabtree/ Anchor/ Havells
Supply & fix Rigid non-metallic PVC conduit 25mm external dia exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc complete all as specified and as directed. Make:-Plaza/ Precision/ Prestoplast// Supreme/ Oriplast
Supply & fix TV co-axial socket 1 module complete all as specified and as directed by Engineer-in-Charge. Make:-Legrand / ABB / Crabtree
Supply & fix RJ11 socket 1 module complete all as specified and as directed by Engineer-in-Charge. Make:-Legrand / ABB / Crabtree
Materials and labour Earthing complete with galvanised steel earth plate electrode 60 Cm x 60 Cm x 6.00 mm thick buried in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to GI wire 4 mm as earthing lead by means of bolts, nuts, check nuts and washers of GI or steel, GI strip projected by 15 mm bore light grade GI pipe and other end connected to earth test point as directed including funnel with watering pipe 20 mm bore light grade galvanised iron, wire mesh, charcoal or coke common salt laid in alternative layer of 15 cm (complete thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1, 50 mm thick pre-cast RCC (1:2:4) type B-1 normal mix cover slab reinforced with 8 mm dia TMT bar 10 Cm c/c both ways and single handle of 10 mm dia round bar including necessary excavation, earth work etc. in soft / loose soil and disposal pf soil to a distance n. exc. 50 m and necessary testing on completion all as shown in electrical plate No. 3 MES Schedule Part-I complete all as specified and as directed.
Taking out unserviceable UG cables of any type and any sizes from trenches etc and removing from the site of work complete all as specified and directed. Note:- (i) Serviceable bricks obtained shall be stacked properly for re-use. (ii) Excavation and earth work shall be measured and paid separately under relevant item of these schedule as mentioned above
Relaying / refixing of old serviceable XLPE insulated PVC sheathed, armoured, aluminium conductor cable 1100 Volt grade of any size in duct/floor/wall with provision of saddle and lugs, joints etc including connection obtained from Item above complete all as directed by the Engr-in-Charge.
Supply and laying XLPE insulated PVC sheathed, armoured, aluminium conductor cable 1100 Volt grade 16 Sqmm 4 core in duct/floor/wall with provision of saddle and lugs, joints etc including connection complete all as directed by the Engr-in-Charge.
Supply and laying XLPE insulated PVC sheathed, armoured, aluminium conductor cable 1100 Volt grade 4 Sqmm 2 core in duct/floor/wall with provision of saddle and lugs, joints etc including connection complete all as directed by the Engr-in-Charge.
Supply and laying XLPE insulated PVC sheathed, armoured, aluminium conductor cable 1100 Volt grade 10 Sqmm 2 core in duct/floor/wall with provision of saddle and lugs, joints etc including connection complete all as directed by the Engr-in-Charge.
Supply and fix GI pipe, 40mm bore, light grade for protection & passing of LT cable fixed to pole/walls/laid under floor/roads complete including fittings/clamps as required at site all as specified for size of 40mm bore dia all as specified & directed at site including taking out old unserviceable one.
Supply and fix LED flood light luminaries of 80W with pressure die cast housing and high output omitted LED and IP66 proction including all accessories and taking down old unserviceable LED light of any capacity complete all as specified and as directed. Make:- Century Magik/ Philips/ Syska/ Crompton/ C&S/ Bajaj/ Havells.
Materials and Labour Synthetic enamel paint , one coat after preparation of surfaces by taking out the old old flood light steel bracket from the boundary wall and refixing after necessary painting complete all as directed by engineer-in-Charge.
Taking out the old Busbar box / Distribution box from the boundary wall and keeping in safe custody and refixing the same to its original position ( bounday wall) and making connection complete.
Supply and fixing Junction pole box of high quality, thermoplastic polycarbonate ( shock proof, rust free, corrosion pfree, acid and chemical resistant, fire returdant, having high proction UV resistant of IK 9 made of halogen and silica free recycable materials IP66/67 degree of proction UV resistant, having high graded internally embedded gasket made of polyurethene and should withstand glow wire test at 96º C and should be flame returdant and self estinguishing with switch gear assemblies as per IEC 439-1, the junction box should have 4 power terminal of 25 sqmm and earth terminal along with SP MCB of 6 Amps fitted in it and dimmenssion of the box shall be 205x 255x 112mm and fixed to tubular / PCC pole using MS flat of size 25mmx 3mm with suitable nuts and bolts and taking out old unserviceable one complete all as directed by Engineer-in-Charge. Make:- Hansel / RMC
C. P. ENTERPRISE
B G Trading Co.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .