Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.6 LAccepted-AOC PLOT NO 32 FF SHIVAJI ENCLAVE NEW DELHI 110027 | NEW DELHI | NEW DELHI | DELHI | 110027 | L1 | Accepted-AOC L1 | |
| 2 | L2₹43.5 L+₹85,150 (1.99%)Rejected-Finance 97 19 JWALA HERI PASCHIM VIHAR NEW DELHI 110063 | WEST | DELHI | 110063 | L2 | Rejected-Finance Being not lowest tenderer | |
| 3 | L3₹43.8 L+₹1.2 L (2.71%)Rejected-Finance | L3 | Rejected-Finance Being not lowest tenderer | |
| 4 | L4₹44.7 L+₹2.0 L (4.66%)Rejected-Finance 110059 NEW DELHI NATIONAL CAPITAL TERRITORY OF DELHI 110059 | WEST DELHI | DELHI | 110059 | L4 | Rejected-Finance Being not lowest tenderer | |
| 5 | L5₹48.6 L+₹5.9 L (13.9%)Rejected-Finance | L5 | Rejected-Finance Being not lowest tenderer |
Tender Value
₹58.0 L
EMD Value
₹1.1 L
Closing Date
23 Dec 2024, 6:00 pmClosed
CWE AF TUGHLAKABAD
HQ CWE AF TUGHLAKABAD AF STATION, TUGHLAKABAD PO SANGAM VIHAR NEWDELHI-110080
SPECIAL REPAIR TO BER COOLING APPLIANCES AND PACKAGED ACs AT AF STN TUGHLAKABAD UNDER GE (AF) TUGHLAKABAD
2024_MES_685534_1
CWE/TKD/TOKEN-68 OF 2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE (A)F Tughlakabad
As per NIT conditions
7 documents required · 7 mandatory
₹0
₹1.1 L
Yes
13 Feb 2025
25 Nov 2024
25 Dec 2024
25 Nov 2024
23 Dec 2024
9 Dec 2024
Amount
Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2.of capacity 2 TR Make:- Blue star,LG,Hitachi as shown Note: 1) Making hole in wall, insulation of copper tubes, PVC drain pipe 3 Mtr, stand for outdoor unit (wall mounted/roof top type), T&P required for installation & making good the disturbed surface is deemed to be included in quoted rates.
Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2 of capacity 1.5 TR Make:- Blue star,LG,Hitachi as shown Note: 1) Making hole in wall, insulation of copper tubes, stand for outdoor unit (wall mounted/roof top type), T&P required for installation & making good the disturbed surface is deemed to be included in quoted rates.
Supply and fixing Industrial socket sheet metal enclosure with socket plug top and MCB single pole and neutral with a two pin and earth plug and socket with one single pole MCB of 32 Amp complete. Make:- Legrand
Taking down old UNSV split,window AC included metal clad socket, copper tubes, included outdoor unit from various location and keep at MES yards or store.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 150 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA, complete all as specified and directed by Engineer-in-charge. Make:- Blu Bird, Micro teck, V-Guard.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 150 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4 KVA, complete all as specified and directed by Engineer-in-charge. Make:- Blu Bird, Micro teck, V-Guard.
M&L Sub main wiring complete with non-metallic rigid PVC insulated fire retardant grade unsheathed 1100V grade multistranded copper conductor cable 2 run of 6 Sqmm single core confirming to IS-694 with copper conductor drawn through PVC casing capping/conduit heavy duty and accessories in walls, roof and floors along with 1 run of 6 Sqmm PVC insulated unsheathed cable with multistranded copper conductor as earth continuity conductor complete including chase cutting by cutter concealed in PVC conduit all as specified and as directed by Engineer-in-Charge. Make: Plaza/Havells/Finolex
Supply , install , commissioning and testing of Air Cooled Packaged Air Conditioners, comprising of Hermetic/Semi - Hermetically sealed Reciprocating or Hermetically sealed Scroll Compressors with microprocessor based control, including copper refirgerant piping, electrtical interconnection between indoor and outdoor units , suitable for operation on R - 407c/R -410a refrigerants and of nominal capacity 7.5 Ton Note: 1) Making hole in wall, insulation of copper tubes, PVC drain pipe 3 Mtr, stand for outdoor unit (wall mounted/roof top type), T&P required for installation & making good the disturbed surface is deemed to be included in quoted rates Make:- Voltas, Blue star.Not:- 2 Refrigerant measure seprately.
Taking down old UNSV air cooled Package Type AC complete set, supply/return air ducting fabricated out of GI sheet 22 Gauge thickness with also remove hanging fastener hook,bolt,GI hanging wire,iron strip with J hook etc, complete all items deposited to the MES store yardas .
Supply and fixing in replacement of aluminium powder coated grills / diffusers for supply air/return air duct, size 400x 400mm, square type with MS volume control dampers complete all as specified and directed by Engr-in-Charge.
M&L for thermal insulation for ducts with 9mm thick nitrile rubber insulation as well as silver heating insulation complete all as specified and directed by Engr-in-Charge.
Design,Supply ,fabrication installation of air distribution system made out of 24 gauge(OGI Sheet) galvanized steel section ducting of thickness as peer Indian Standard (IS 655:1963) including 3 mm rubber gasket ,nut and bolts for jointing.The supply air and return air duct over the ceiling with necessary inbuilt stiffeners to maintain desired noise level from AHU to condition room ,of commercial grade VII as per IS 655 with main air chamber complete with insulated with TF quality EPS sheet 50 mm thick density not less than 36 Kg /Cum and covered with chicken wire mesh ,vapour barrier PVC aheet and 10 mm thick cement and plaster with suitable MS supporing arrangements from floor /RCC roof/Ceiling /Wall.
Design,Supply ,fabrication installation of air distribution system made out of 22 gauge(OGI Sheet) galvanized steel section ducting of thickness as peer Indian Standard (IS 655:1963) including 3 mm rubber gasket ,nut and bolts for jointing.The supply air and return air duct over the ceiling with necessary inbuilt stiffeners to maintain desired noise level from AHU to condition room ,of commercial grade VII as per IS 655 with main air chamber complete with insulated with TF quality EPS sheet 50 mm thick density not less than 36 Kg /Cum and covered with chicken wire mesh ,vapour barrier PVC aheet and 10 mm thick cement and plaster with suitable MS supporing arrangements from floor /RCC roof/Ceiling /Wall.
Interconnecting electrical cabling for Package units between indoor & outdoor units(12 RM per Circuit)
S & F for Refrigerant Charging
Canvass connection fire retardant (1 No per machine)
Copper refrigerant piping for Package split units duly insulated with nitrile tube and supported (10 RM per Circuit)
Hard PVC Drain pipe of 25 mm dia with fittings duly insulated(10 RM Per Machine)
MS stand for Ductable outdoor units
Supply and fixing in replacement PVC insulated, FRLS, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 35 sq mm 3.5 core all as specified and as directed by Engineer-in-Charge. Make: Plaza/Havells/Finolex
M&L for Rubber Matting one sided chequered and other side plain 19 mm thick insulated for 11000 Volts ISI Marked in Standard size 2m x1 m
Supply,Installation & Testing One No Temper Proof Electronic Digital Thermometer ,Hygrometer with recording & display facility fixed at Plant Room from Relative Humidity & Return Air Temp Sensor with necessary fixing arrangement
RefAir Technical Services (BID ID -3186215)
M/S S.K.Electricals (BID ID -3196326)
V r traders (BID ID -3195555)
Sadh builders (BID ID -3196153)
Neeraj Enterprises (BID ID -3195596)
Sumit Enterprises (BID ID -3196402)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .