Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
₹3.5 L
EMD Value
₹3,500
Closing Date
22 Jan 2024, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Sivakasi Corporation Commissioner
Sivakasi Corporation office Rathinam nagar Sivakasi
Providing New HDPE Tank with Bore well at Ward No 06 in Sivakasi City Municipal Corporation
2024_MAWS_407614_9
8823/2023/E2
Open Tender
Civil Works
Works
15 days
SIVAKASI
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹3,500
Yes
22 Jan 2024
9 Jan 2024
22 Jan 2024
9 Jan 2024
22 Jan 2024
9 Jan 2024
Amount
Charges for conducting Geophysical Survey to locate for favourable point for drilling 4 ½" dia borewell
Providing 4½" dia borewell in hard rock area including all accessories etc., complete as per standard specifications.
Supply and fixing of 140mm OD PVC pipe etc., complete as per standard specifications.
Supply and delivery of PVC and GI Specials as Per Standard Specification Asper TWAD P.No. 37 (5.1B) i) 4" Dia PVC Pipe
ii) 4" Dia Cowl
iii) 32 mm G.I. Pipe
iv) 20 mm G.I. Pipe
v) 15 mm G.I. Pipe
viii) 1" G.I. Elbow
ix) ½" G.I. Elbow
x) ½" M.S. Union
xi) 1" G.I. Union
xii) ½" G.I. Union
xiii) 1" G.I. Hex Piple
xiv) ½" G.I. Hex Nipple
xvi) 1" G.I. Coupling
xvii) 1" G.I. Tee
xix) 1" Ball Valve
xx) ½" Coupler
xxi) ¾" G.I. Elbow
xxii) ¾" x ½" G.I. Elbow
xxiii) ½" Ball Valve
xxiv) ½" G.I. Bend
xxv) ½" Tap
xxx) 32 mm HDPE Hose
Supply and delivery and fixing of 1000 Liter HDPE tank as per IS 12701 / 1996 including loading, unloading, transportation and labour charges for fixing of the GI pipes and specials for pipe connection works including cutting, threading and fixing charges etc.,
Earth work excavation and depositing on bank with initial lead of 10 m and lift of 2 M in narrow trenches for laying of pipes for water supply in the following type of soils as directed by Departmental officers b Hard stiff clay, stiff black cotton, hard red earth, shales, murram gravel, stoney earth and earth mixed with small size boulders and hard gravelly soil complete etc..,
Supplying and filling in foundation and basement with Crushed Stone Sand (M- Sand) in layers of not more than 15cm thick well rammed watered and compacted etc., complete complying with standard specification.
Plain cement concrete 1:4:8 (One cement four sand and eight aggregate) using 40mmH.B.G.metal for foundation and flooring including dewatering if 'necessary and laid inlayer of not more than 15 cm thick complying with standard specification.
Brick work in cement mortar 1:5 (One cement and Five sand) using country bricks of size 8 ¾" x 4¼"x2¼ " including cost and conveyance of allmaterials to site and all other labour charges and incidential charges etc., complete complying with standards specifications.
Plastering with cement mortar (1:5) 12mm ,thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications (S.I.306)
Supplying and filling the basement with Good Earth filling in layers of not more than 15cm thick well rammed watered and compacted - etc., complete complying with standard specification.
Plain Cement Concrete 1:2:4 (one cement, two Crushed Stone Sand (M- Sand) and four coarse aggregates) using 20mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying and labour charges etc., complete as per standard specification
Supply and run of 2 of 6 sq.mm. (84 / 0.3) PVC insulated SC unsheathed copper conductor of 1100V on 7 / 20 GI bearer wire for service connection mains
Supply and run of 2 x 1.5 sq.mm. (22 / 0.3) PVC insulated SC unsheathed copper conductor of 1100V grade in 25mm dia GI pipe (Class 'B') suitably bent at both ends with necessary angle iron upright and end supports for mains
Supply and fixing of 15 A arial fuse unit on suitable MS plate with hylem sheet on thetapping pole with necessary clamps. only.
Wiring with 2 x 1.5 sq.mm. (22 / 0.3) PVC insulated SC unsheathed copper conductor cable of 1100V grade in suitable heavy gauge MS conduit pipe on wall and ceiling with MS accessories with switch box with 5A FT switch inflush with wall and covered with hylum sheet of 3mm thick with painting of suitable colour with continuous earth wire connection of 14 SWG TC wire for light point / fan point (for electronic regulator)
Supply of THREE PHASE SUBMERSIBLE PUMPSET SUITABLE FOR 100MM DIA BOREWELL of lpm against 100meter head as per ISI foot valve arrangements with 30 mm G.I.Pipe 6m with 2 M.S. Union and all accessories etc.,complete as per standard specifications.
Supply and delivery of THREE PHASE Panal Board DOL Two level Guard and auto start complete as per standard specifications
Labour charges for erection of compressor motor in borewell up to 115 M dia including fixing of suction pipe up to a maximum depth of 110 M and elivery pipes and erection of DPIC Switch Complete and testing the pumps on trial run for ten days including siging of completion reports as required by the E.B. authorities as instructed by the departmental officers.
PALANIKUMAR K
stage.html
html • 0.02 MB
finance_485246.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .