| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | FIRST₹21.4 LAccepted-AOC | FIRST | Accepted-AOC BEING LOWEST | |
| 2 | SECOND₹22.7 LRejected-Finance 39 SR LAYOUT MAIN ROAD NAL WING TUNNEL ROAD MURUGESH PALYA BANGALORE 560 017 | BENGALURU URBAN | KARNATAKA | 560017 | SECOND | Rejected-Finance BEING NOT LOWEST |
Tender Value
₹27 L
EMD Value
₹54,000
Closing Date
8 Sept 2022, 6:00 pmClosed
GE (AF) MARATHAHALLI
GE AF MARATHAHALLI WIND TUNNEL ROAD, KEMPAPURA, YEMALUR POST, BANGALORE. PIN- 560037
REPAIRS TO INTERNAL EXTERNAL ELECTRIFICATION AND REPAIR MAINT OF POWER FENCING AT ASTE UNDER GE AF MARATHAHALLI
2022_MES_545060_1
8979/E8
Open Tender
Civil Works
Item Rate
270 days
GE (AF) MARATHAHALLI
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE (AF) MARATHAHALLI
₹54,000
Yes
10 Oct 2022
12 Aug 2022
13 Sept 2022
12 Aug 2022
8 Sept 2022
26 Aug 2022
Amount
Taking down carefully copper/aluminium point wiring of any type of batten or conduit (Light, Fan, Socket or power) complete removing material from site and making good the disturbed surfaces of walls, roofs etc including two coats of white/colour washing/distempering etc to match the existing complete all as directed by EIC.
Taking down carefully unserviceable sub main wiring of any size and type including making good the disturbed surfaces of walls, ceilings etc including two coats of white /colour washing/ distempering etc to match the existing complete all as directed by EIC.
Taking down carefully unserviceable distribution boards/metal enclosures of any type and capacity including wooden board and making good the disturbed surfaces of walls, ceilings etc including two coats of white/colour washing/ distempering etc to match the existing complete all as directed by EIC.
M & L point wiring with 1.5 sqmm nominal cross sectional area, single core, 1100 Volts grade, stranded, PVC insulated, unsheathed copper conductor cable in and including PVC concealed conduit of 25 mm dia or higher, medium grade complete with and including all PVC conduit accessories/fittings, brass screws, washers etc, Sunk Zinc coated pressed steel terminal boxes including all cutting/chases etc in walls, making good to walls, ceiling etc including two coats of white/colour washing/ distempering etc to the disturbed surfaces to match the existing with 3 mm thick plastic laminated sheet top cover concealed in wall with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, PVC insulated copper conductor cable, unsheathed and connected to common earth and earth dolly complete all as specified and directed by Engr -in -charge for One light point / bell point controlled by one, one way switch.
All asper Item No.04 above but One fan point controlled by one, one way switch.
All asper Item No.04 above but one light point controlled by 2 way switch.
All asper Item No.04 above but for One 3 pin, 05 /06 Amps socket outlet point on same board controlled by one , one way 05/06 Amps switch
All asper Item No.04 above but for One 3 pin, 05 /06 Amps socket outlet point on independent board controlled by one , one way 05/06 Amps switch
All asper Item No.04 above but capping cassing wiring One Light/fan point controlled by one, one way switch.
All asper Item No.04 above but capping cassing wiring for One 3 pin, 05 /06 Amps socket outlet point on independent board controlled by one , one way 05/06 Amps switch
M & L point wiring with 2.5 sqmm nominal cross sectional area, single core, 1100 Volts grade, stranded, PVC insulated, unsheathed copper conductor cable in and including PVC concealed conduit of 25 mm dia or higher, medium grade complete with and including all PVC conduit accessories/fittings, brass screws, washers etc, Sunk Zinc coated pressed steel terminal boxes including all cutting/chases etc in walls, making good to walls, ceiling etc including two coats of white/colour washing/ distempering etc to the disturbed surfaces to match the existing with 3 mm thick plastic laminated sheet top cover concealed in wall with and including continuous earth wire of size 2.5 Sqmm nominal cross sectional area, single core, PVC insulated copper conductor cable, unsheathed and connected to common earth and earth dolly complete all as specified and directed by Engr -in -charge for one 15 /16 Amps socket outlet point on independent board.
All asper Item No.11 above but capping cassing wiring for One 3/5 pin, 15 /16 Amps socket outlet point on independent board with 2.5 sqmm cables.
S & switch piano flush type, 05/06 Amps single pole, one way 240 volts complete all as specified & directed
Supply & fixing of socket outlet 3 pin, 05/06 Amps (2-in-1 Multipurpose) flush type 240 volts complete all as specified & directed.
Supply & fixing of socket outlet 3 pin, 15/16 Amps (2 -in-1 Multipurpose) flush type 240 volts complete all as specified & directed.
Supply & fixing switch piano flush type, 15 /16 Amps single ploe, one way 240 volts complete all as specified & directed
Supply & fixing of ceiling rose surface three terminals complete all as specified & directed.
Supply & fixing in repairs bell push flush type 5 Amps complete all as specified & directed.
S & F in repairs Door bell AC, 230 volts, single pole complete all as specified & directed..
Supply & fixing in repairs Switch socket combination 2-in-1, 3 pin, 5 and 15 Amp flush type complete all as specified & directed.
Supply & fixing in repairs Switch socket combination 2-in-1, 3 pin, 5 Amp flush type complete all as specified & directed..
Supply & fixing in repairs modular switch 06 Amps 1 module complete all as specified & directed
Supply & fixing in repairs modular switch2 way , 06 Amps 1 module complete all as specified & directed
Supply & fixing bell push modular type 6 Amps complete all as specified & directed.
S & F modular socket 06 Amps 2/3 pin combined 2 module complete all as specified & directed.
Supply & fixing in repairs modular switch 16 Amps 1 module complete all as specified & directed
S & F modular in repairs socket 06/16 Amps 2/3 pin combined 2 module complete all as specified & directed.
S & F electronic in repairs fan regulator modular type, 2 module, 120W including complete all as specified and directed.
S & F in repairs electronic fan regulator stepped, socket type 400W including removing the switch board panel and making the provision for fixing the electronic type regulator and refixing the same complete all as specified and directed.
S & F MCB DB SPN 4Way with 200 Amps rated busbar, Double door, flush to wall including all cutting etc on wall and making good the disturbed surfaces to match the existing complete all as specified and directed.
S & F MCB DB SPN 8Way with 200 Amps rated busbar, Double door, flush to wall including all cutting etc on wall and making good the disturbed surfaces to match the existing complete all as specified and directed.
S & F MCB, DB SPN 12Way with 200 Amps rated busbar, Double door, flush to wall including all cutting etc on wall and making good the disturbed surfaces to match the existing complete all as specified and directed.
S & F MCB, DB TPN 4Way, Double Door flush to wall including all cutting etc on wall including making good the disturbed surfaces to match the existing in replacement of old U/s complete all as specified and directed.
S & F MCCB, DB Vertical TPN 8 Way 'A' Frame,Including MCCB TPN 125 Amp Beaking capacity 25Ka -01 nos, Double Door flush to wall including all cutting etc on wall including making good the disturbed surfaces to match the existing in replacement of old U/s complete all as specified and directed. Make -Havells or equivalent
M & L for sub main wiring complete with two runs of 2.5 Sqmm single core FRLS grade PVC insulated unsheathed cable 1100Volt grade multistranded copper conductor drawn through and including PVC conduit and accessories surface on wall, roofs etc with one run of PVC insulated solid copper conductor 2.5 Sqmm single core as earth continuity conductor connected with earth dolly and mains complete all as specified and directed. (Two runs of 2.5 Sqmm single core with one run of PVC insulated solid copper conductor 2.5 Sqmm single core as earth continuity conductor and PVC conduit shall be measured as one unit)
M & L for sub main wiring complete with three runs of 4 Sqmm single core FRLS grade PVC insulated unsheathed cable 1100Volt grade multistranded copper conductor drawn through and including PVC conduit and accessories surface on wall, roofs etc with one run of PVC insulated solid copper conductor 4.0 Sqmm single core as earth continuity conductor connected with earth dolly and mains complete all as specified and directed. (Three runs of 4.0 Sqmm single core with one run of PVC insulated single core copper conductor 4.0 Sqmm as earth continuity conductor and PVC conduit shall be measured as one unit)
M & L for sub main wiring complete with two runs of 10 Sqmm single core FRLS grade PVC insulated unsheathed cable 1100Volt grade multistranded copper conductor drawn through and including PVC conduit and accessories surface on wall, roofs etc with one run of PVC insulated solid copper conductor 10.0 Sqmm single core as earth continuity conductor connected with earth dolly and mains complete all as specified and directed. (Two runs of 10.0 Sqmm single core with one run of PVC insulated single core conductor 10.0 Sqmm single core as earth continuity conductor and PVC conduit shall be measured as one unit)
Material and labour for Cutting, chases, pinning in making good to facing where required and pointing in cement mortar 1:3 to ends or edges of landing, steps, chills, sunshades shelves, lintels etc, and cutting chases for concealed water tubing or concealed conduit wiring etc; and making good, cutting not exc 10 cm girth complete all as specified and directed.
S & F MCB SPN 40 Amps, 'C' series, 240 V complete incl making conections all as specified and directed.
S & F MCB SP 6-32 Amps, 'C' series, 240 V complete incl making conections all as specified and directed.
S & F MCB TPN 63 Amps incl making connections all as specified and directed.
S & F MCB TP 63 Amps incl making connections all as specified and directed. Make -Havells or equivalent.
S&F in repairs Lumiline LED tube with box type fitting , 2 feet, 10 watts alongwith tube complete all as specified and directed. Make : Bajaj /CG/Philips/Havells
Supply and fixing in repairs LED lights batten type fittings 1x 18W, 220V AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
S&F in repars lumiline LED tube with box type fitting Decorative ultra slim square profile LED lighting fixture with extruded polycarbonate, environment, friendly, energy efficient 4Ft of 20 Watts and making all necessary connections in the existing fittings and refixing the same back to its position complete all as specified and directed.
Supply & Fix in repairs linear LED T8 tubular lamp 18W with extruded aluminium/PC body and PC diffuser complete with inbuilt driver incl making necessary connections in the existing fittings to suit the LED tube complete all as specified and directed.
S & F in repairs LED fitting of 15 watts - Square surface mounted LED flat panel down light, PDC aluminum housing and PMMA diffuser makes it a robust Luminaire alongwith driver and 15W LED lamp complete all as specified.
Supply only LED lamp 10 watt complete all as specified and directed.
Supply only LED lamp 5 watt complete all as specified and directed.
Taking down ceiling fan/Exhaust fan, sealing the cable ends dismantling the fan blade kept in safe costody complete all as specified. Note: (a) Servicing and Spares will be measured and paid seperately .
M & L for painting of ceiling fan complete, at site with synthetic enamel paint by spraying including filling cavities with filler,one coat after cleaning all dust all as specified.
Hanging only ceiling fan and connecting up including provision of cable from ceiling rose or connector to fan all as specified ,and any addn/alteration /threading if required to down rod shall be done by contractor with out any extra cost.
Labour for servicing the ceiling / exhaust fan of any make including greasing /oiling /repairs and replacing the spares such as cater pin unserviceable / rusted bolts, split pins, rubber wheel, bearing, washers, bush all as specified and directed .
Supply only GM bush of ISI marked suitable for ceiling fan of size 1200 / 1400mm sweep.
Supply only ball bearing suitable for ceiling fan of 1200 /1400mm sweep. Make : SKF, bearing No 6202 or equivalent in NBC.
Supply only capacitors 2.5 MFD of the fan in position as directed by Engr - in - Charge
Supply only capacitors 4.0 MFD of the fan in position as directed by Engr - in - Charge
M & L for dismantling the defective exhaust fan motor by taking out the burnt copper winding, rewinding the motor with super enamelled copper winding wire of existing gauge and weight including replacement of all insulation material, "O" rings and other petty items required for making motor functional and checking the winding leak proof complete all as specified and directed.
M & L for dismantling the defective Ceiling fan motor by taking out the burnt copper winding, rewinding the motor with super enamelled copper winding wire of existing gauge and weight,warnishing , including replacement of all insulation material, and other petty items required for making motor functional and checking the winding leak proof complete all as specified and directed.
M&L for straight through joints (epoxy) heat shrinkable type for UG cable including joint kit and all accessories complete for making joints suitable for LT UG Cable of Aluminium conductor upto 16/25 Sqmm 3.5 core complete all as specified and directed. (Make : 3M /Densons).
All as per ser item no. 60 here-in-before but of size upto 35/50 sqmm x 3.5 core complete all as specified and directed. (Make : 3M /Densons).
All as per ser item no. 60 here-in-before but of size upto 95 to 150 sqmm x 3.5 core complete all as specified and directed. (Make : 3M /Densons).
All as per ser item no. 60 here-in-before but of size upto 150/185 sqmm x 3.5 core complete all as specified and directed. (Make : 3M /Densons).
All as per ser item no. 60 here-in-before but of size upto 240/400 sqmm x 3.5 core complete all as specified and directed. (Make : 3M /Densons). Note for ser item nos 60 to 64 : Excavation and earth work shall be measured and paid seperately.
M & L for Fault locating of LT UG cables by using measuring instruments and rectification of the same by using epoxy cable joints of suitable size of cables and testing the phase contuinity of the cable complete all as specified and directed. Note : Cable joint kit and Excavation/earth work shall be measured and paid seperately.
Supply & Fixing in repairs MCCB TPN 415 Volts 250 Amps rating with breaking capacity of 35 kA with adjustable thermal & magnetic release complete with making all connections as per site requirement as specified and directed.
All as per ser item no.66 here-in-before but MCCB TPN 415 Volts 100 Amps, 25 kA complete with making all connections as specified and directed.
All as per ser item no.66 here-in-before but MCCB TPN 415 Volts 63 Amps, 25 kA complete with making all connections as specified and directed.
Supply and fixing four pole changeover switch disconector with advance neutral 415 volt 50 Hz 200 amps in sheet steel enclosure and Conforming to IS / IEC : 60947 - 3 including dismantling old one complete all as directed. Make - L & T /Siemens/Schneider.
Supply and fixing four pole changeover switch disconector with advance neutral 415 volt 50 Hz 100/125 amps in sheet steel enclosure and Conforming to IS / IEC : 60947 - 3 including dismantling old one complete all as directed. Make - L & T /Siemens/Schneider.
Supply and fixing in repair for swich disconnector fuse unit in sheet steel enclosure TPN current rating 200 Amp with HRC Fuse including disconnecting and taking out unserviceable one complete all as directed. Make - L&T / Havells / HPL .
Supply and erecting steel tubular pole, swaged, complete with cast iron base plate, finial taper plug, bolts, nuts, washer and screws including painting with two coats of aluminium paint over one coat of red oxide primer on all exposed surfaces and tarring with black bituminous paints to portion embedded in PCC including numbering of poles with two coats of synthetic enamel paints, type 410-SP-22 (8.5 meter long) complete, Including disconnecting and taking out old damage PCC pole all as directed. (Note Excavation & Earth work and PCC foundation/base shall be measured and paid separately under relevant items of this BoQ)
M & L for Cross arms, bracing, supports, clamps and back plate, fabricated from structural steel section including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as directed including two coats of synthetic enamel paint over a coat of red oxide primer, complete all as directed .
Dismantling and taking out servicable cross arms, bracings, supports, clamps and back plates from existing poles / dismantled poles / pole structures complete all as directed.
M & L for painting the surface of post top poles of size 50mm dia and 3 mtr length by applying two coats of synthetic enamel paint complete all as specified and directed by Engr-in-charge.
M & L for Painting of steel pole/PCC pole with cross arms, clamp of any length and shape for LT overhead line with single coat of aluminium paint including preparation of the existing surface including marking pole numbers in a 20 cm dia yellow circle & marking six black & four yellow bends width 15 cm by fluorescent paint, from bottom of pole to 1.5 Mtr height and providng three nos of Red ,Yellow & Blue of reflecting strip of 25 mm width adhesive PVC tape around the pole at suitable height complete all as specified and directed.
Excavation in trenches in soft /loose soil not exceeding 1.5 metre wide and not exceeding 1.5 metre deep for laying of cables etc, getting out and forming bottom surface to required gradient complete.
Excavating in trenches exceeding 1.5 m wide and not exceeding 3 m depth and not less than 1.5 m in depth for laying of cables & foundation of poles , stay assembly and getting out in any type of soil complete all as specified and directed .
Returning filling including spreading levelling watering and well ramming to excavated soil in layers not exc 25 cm thick each complete all as specified.
Removing excavated material to adistance not exc 50m and depositing where directed at a level not exc 1.5m above the starting point in soils complete all as specified.
Sand (Tibba) cushioning to cables with a layer of sand 8 cm deep before laying the cable and 15 cm depth after laying of cable, complete all as specified.
Brick protection cover on cable with sub class 'B' brick, laid dry and flat adjacent to each other complete all as specified.
M & L for G.I. tubing light grade of size 50mm bore for protection of cables to be laid under roads, crossings/culverts complete all as specified and directed.
All as per Srl item No 83 here in above but GI pipe of size 80 bore.
Taking up underground unservicable cable of any size from existing trench including bricks, etc and removing of materials from work site all as directed by Engr-in-charge.
Supply, laying, jointing & testing in trenches or passing through pipe, 1100 volts grade, XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured LT electric power under ground cables, heavy duty with aluminium conductor of cross sectional area 400 sqmm 3.5 core with all fixing & connecting accessories such as Alluminium cable lugs, cable gland, nut, bolts, washer etc complete as specified and as directed.
Ditto All as per Srl item No 86 here in above but size of cable 240 Sqmm 3.5 core
Ditto All as per Srl item No 86 here in above but size of cable 10 Sqmm 2 core
Ditto All as per Srl item No 86 here in above but size of cable 25 Sqmm 4 core
Ditto All as per Srl item No 86 here in above but size of cable 95 Sqmm 3.5 core
Ditto All as per Srl item No 86 here in above but size of cable 50 Sqmm 3.5 core
S&F in repairs single pole and neutral enclosure with two pin and earth plug and socket including 1 No. MCB 20 Amp capacity complete all as specified and as directed.
Supply and fixing in replacement of 1100 Volts grade heavy duty cable 10 Sqmm 2 core with PVC insulated stranded aluminium conductor served with inner sheathing of PVC tape and over all PVC sheathed in service connection suspended by insulated hanger not more than 1 mtr a part including 4mm suspension wire, one twin core cable flat or circular complete all as specified and directed by Engr-in-Charge.
Material and labour for boring of holes under road, pavement hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure.
M & L for Earthing complete with galvanized iron or steel plate electrode 600 mm x 600 mm x 6.0 mm buried directly in ground vertically in pit of depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides with mixture of charcoal and common salt in alternate layers and electrode connected to galvanized iron strip 32 x 6mm dia as earthing lead by means of GI bolts, nuts, check nuts and washers, earth wire protected by galvanized steel pipe 15 mm bore (light grade) connected to machinery/ equipment all as shown in electrical plate No. 5 of SSR Part I and including necessary excavation and earth work in any type of soil, 20 mm bore light grade GI pipe for watering funnel wire mesh, PCC (1:3:6), type C-1 chamber, RCC (1:2:4), type B-1, reinforced with 6 mm dia MS round bars @ 15 cm c/c both way for cover and MS frame etc., complete all as specified.
Material & labour for fixing of Earth continuity conductor GI strip of size 25X 4 mm with nut bolts at joints , fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles,equipments or any other indicated situation for loop earthing etc, strip fixed on with epoxy insulatorof suitable size all as specified and directed by Engineer-in-Charge.
Supply and fixing in repairs New generation, post-top lantern of 40 Watts, 240V, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source including making all necessary wiring, provn of suitable fitments and connecting upto control box complete all as specified and directed. Make : Bajaj /CG/Philips/Havells
S&F PVC Junction box of size 255X200X100mm inside dimension fixed on pole by means of mild steel clamps with hinged door, bolt and nuts, provn for cable entry for incoming and outgoing including MCB 2.5 amps-1 No and 4 way connector-1nos neccessary connection duly fixed with clamps on pole and including cable glands threaded type IP55/IP65 made of polymide with lock nut complete all as specified. Make : Sintex GSJB2520 or equivalent.
M&L for PCC (1:4:8) type D-2 using 40mm graded crushed stone aggregate as in foundations for electric poles, filling and mass concrete complete all as specified and directed.
M & L for PCC (1:3:6) type C-1 using 20mm graded crushed stone aggregate as in coping of the LT poles including form work complete all as specified
Supply and fixing of Endura Citylite Platinum, 45 W LED Street Light fittingpressure die cast aluminium housing, heat resistance toughened glass, IP-66 protection in replacement of old UNSV 70W HPSV light fittings complete all as specified and directed.
Supply and fixing of Endura Cityliner Neo, 72 W LED Street Light fitting pressure die cast aluminium housing, heat resistance toughened glass, IP-66 protection in replacement of old UNSV 150W HPSV light fittings complete all as specified and directed.
Supply and fixing LED flood light 120 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed.
S&F in repairs LED Driver unit suitable for 30 to 45 watt capaity complete all as specified and directed. Make - Bajaj /CG/Philips/Havells
S&F in repairs LED Driver unit suitable for 70 to 150 watt capaity complete all as specified and directed Make - Bajaj /CG/Philips/Havells
Supply and fixing in repairs 36W LED Fitting, 2 x 2 recess / Surface LED flat panel with high brightness LED for glare free homogenous illumination including LED driver complete all as specified including taking down old unserviceable fittings.
Supply only Capacitor (MPP, Heavy duty) 440 volts with inrush current limiting coil, 5 KVAR
Supply only Capacitor (MPP,Heavy duty) 440 volts with inrush current limiting coil, 10 KVAR
Supply only Capaitor duty contactor 7 KVAR
Supply only Add on Auxiliary contact Block 4 NO
Maintenance of storage type electric water heaters(Geyser) of storage capacity 25 ltrs comprising of the following tasks and all as per specified and directed by Engr-in-Charge. (a) Inspection taking down, opening (dismantling),descaling, brushing cleaning of storage tank and painting internally with one coat of proprietary bituminous compositions not liable to impart taste or or odour or otherwise contaminate the water. (a) Examine water tightness of storage tank after cleaning. (b) Carry out operation of all stop cocks,pressure reducing valves etc to ensure free movement of the working parts. (c) Replacement washers and glands of all taps and ball valves to ensure water tightness. (d) Visual examination of fusible plug to (e) Descaling of the immersion type heating element and cleaning with diluted hydrochloric acid or "clear pedette" solution and testing before refitting. (f) Replacement/repair of neon lamp/indicator lamp. (g) Replacement of the rubber/PVC gaskets to ensure water tightness.. Note : (i) Attending complaint during the currency contract period on phone call and rectification with in 24 Hrs. (ii) The spares will be measured and paid seperately.
All as per Item No-112 above, but of 50 ltrs storage capacity.
Supply only new heating element suitable to existing model and make 2 KW Dual clip type/tri angle type and round type with rubber gasket suitable for geysers up to 25/50 Ltr capacity . Make: Theeta /Elteck or equivalent
Supply only new heating element suitable to existing model and make 1.5 KW Dual clip type/tri angle type and round type with rubber gasket suitable for geysers up to 25/50 Ltr capacity . Make: Theeta /Elteck
Supply only thermostat clip type (Range 30 C to 80 C and acting at 70 C) for geysers up to 50 Lts. range 30 C to 80 C and acting at 70 C all as specified .
Supply only PVC connections up to 600 mm in length suitable to connect GI pipe 15 mm dia to hot water outlet of geyser.
Supply only PVC connections up to 650 mm in length suitable to connect GI pipe 15 mm dia to cold water inlet of geyser.
Supply only pressure release valves suitable for geyser up to 50 ltrs capacity
M&L for arresting the leakage in inner tank of any size/make of geyser complete with brazing work and leak test, servicing etc
Taking down unserviceable power fencing 12 runs of GI wire on 1.2 mtr height stand post on wall including break away insulators, strain insulators, intermediate post, end post etc all connected items complete all as directed to Engr-in-Charge.
Supply, install and testing of energizer (CS 250- V3) with CE marking conform to IEC 60335-2-76, IEC 61000-3-3 and IS 8437 standards including necessary connecting up control wire, complete all as specified and directed by Engr-in-Charge.
Supply, install and testing of conventional charger including necessary connection, complete all as specified and directed by Engr-in-Charge.
Supply and fixing of live lite for power fence complete with necessary connecting up all as specified and directed by Engr-in-Charge.
Supply, install and testing of hooter with strobe light of 12V DC, 100 db rating complete all as specified and directed by Engr-in-Charge.
Supply, install and testing of 12V/65AH battery complete all as specified and directed by Engr-in-Charge.
Supply, install and testing of Lightening diverter kit (dual channel) complete all as specified and directed by Engr-in-Charge.
Supply, install and testing of IP65 rated outdoor console rack on suitable size MS angle iron ISA 2525 with 3mm thick with minimum 600 mm height complete all as specified and directed by Engr-in-Charge.
Supply and fixing of Intermediate posts : 45 x 25 x 2 mm KIWITAH post of 1.5 meter length with top bend having facility to fix 12 strands complete all as specified and directed by Engr-in-Charge.
Supply and fixing of 50 NB class B strain post of 1.5 meter length duly galvanized with top bend with required hardware complete all as specified and directed by Engr-in-Charge.
Supply and fixing of 25 mm dia support duly galvanized post suitable to support strain post with hardware complete all as specified and directed by Engr-in-Charge.
Supply and fixing of Break away insulators should be suitable for 15 KV rating (dielectric strength) complete all as specified and directed by Engr-in-Charge.
Supply and fixing of End strain hooks of 6mm dia complete all as specified and directed by Engr-in-Charge.
Supply and fixing of strain insulators made up of polypropelene co-polymer complete all as specified and directed by Engr-in-Charge.
Supply and fixing of wire tightener LM6 grade for tightening complete all as specified and directed by Engr-in-Charge.
Supply and fixing of joint clamps will be made of zinc coated bolt with clamp & SS nuts for interconnections of power fence complete with fixing all as specified and directed by Engr-in-Charge.
Supply , fixing, Installation, commissioning and testing of power fence incl restoration of power fence at ASTE incl all charges comprising of HT GI wire 2.5 mm thick (Power Fence) complying with IS 398 Part 2 including testing complete all as specified and directed by Engr-in-Charge.
Supply and fixing of double insulated cable of 2 mm dia hot dip galvanized wire with 9 mm outer dia having double insulation to withstand breakdown voltage of more than 15 KV along with HDPE conduit including testing complete all as specified and directed by Engr-in-Charge.
Supply and fixing of warning sign board of polyethylene plastic material with yellow background and red letters on both sides in english / Kannada language and size of 250 x 150 x 3 mm complete all as specified and directed by Engr-in-Charge.
GKR and CO
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .