Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.0 CrAccepted-AOC F 18 ANSAL COMPLEX OPP JWALA HARI MARKET PASCHIM VIHAR NEW DELHI 110063 | NEW DELHI | WEST DELHI | DELHI | 110063 | ₹20.0 Cr | L1 | Accepted-AOC Being lowest |
| 2 | L2₹20.9 CrRejected-Finance | ₹20.9 Cr | L2 | Rejected-Finance Not being lowest |
| 3 | L3₹23.3 CrRejected-Finance | ₹23.3 Cr | L3 | Rejected-Finance Not being lowest |
| 4 | L4₹23.7 CrRejected-Finance PLOT NO 137 2ND FLOOR AVTAR ENCLAVE PASCHIM VIHAR NEW DELHI 110063 | WEST | DELHI | 110063 | ₹23.7 Cr | L4 | Rejected-Finance Not being lowest |
| 5 | L5₹26.0 CrRejected-Finance K 99 LGF KALKAJI NEW DELHI 110 019 | NEW DELHI | SOUTH EAST DELHI | DELHI | 110019 | ₹26.0 Cr | L5 | Rejected-Finance Not being lowest |
Tender Value
Refer Docs
EMD Value
₹12.5 L
Closing Date
8 Feb 2021, 6:00 pmClosed
Chief Engineer Delhi Zone
HQ Chief Engineer Delhi Zone Delhi Cantt-10
ADDN ALTN AND REPAIR OF MAIN BLDG AND OTM ACCN OF ARMY HOSPITAL (RR) DELHI CANTT UNDER GE EM RR HOSPITAL DELHI CANTT-10
2020_MES_402506_1
CEDZ 35 OF 2020-21
Open Tender
Civil Works
Delhi Cantt
MES contractor enlisted in MES under class SS cat a i and b i having deposited Standing Security of Rs 15.00 lakh with department. Contractors not enlisted in MES should meet the MES enlistment criteria corresponding to appropriate class and categor
9 documents required · 9 mandatory
₹3,000
GE EM RR HOSPITAL
₹12.5 L
Yes
1 Mar 2021
10 Dec 2020
10 Feb 2021
10 Dec 2020
8 Feb 2021
19 Jan 2021
Amount
Excavation in trencehs n exc 1.5 mtr wide and n exc 1.5mtr in depth for foundation, getting out in any type of hard and desnse soil complete all as specified and directed by Engineer-in-Charge.
Excavation in post holes in Hard/dense soil (or similar holes) each not exc 0.5 cum, getting our, returing, filling in and remming earth of broken rubble mixed with earth around, in layers not exceeding 25 cm complete all as specified and directed.
M&L for PCC 1:4:8 type D-2 (using 40 mm graded stone aggregates) as in foundation filling and mass concrete complete all as specified and directed.
M&L for PCC 1:3:6 type C-2 (using 20 mm graded stone aggregates) as in foundation filling and mass concreting complete all as specified and directed
M&L 75mm thick cement concrete type D2, 1:4:8 (using 40mm graded stone agg) as in sub base floor complete all as specified and directed
M&L 25mm thick cement concrete type B1, 1:2:4 (using 20mm graded stone agg) as in floor complete all as specified and directed
Surface excavation n.exc 30 cm deep and averaging 15 cm deep and getting out soft/loose soil complete all as specified and directed
M&L sand filling over concrete surface of under interlocking paver blocks complete all as specified and directed
M&L Machine pressed precast & prepolished coloured concrete interlocking paver block any shape and size of 80mm thick with grey cement pigment of M-40 grade complete all as specified and directed
S & F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc (Fe-410 Gde E-290) complete all as specified and directed
S&F MS Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment (Fe-410 Gde E-290) complete all as specified and directed.
M&L preparation of new untreated iron surface of any description, not otherwise described, over 10cm width or girth and two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed
Pre- painted galvalum aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with J or L type hook screws complete all as specified and directed
Removing of excavated material or soil n.exc 50m and depositing where directed at a level n.exc. 1.5m above the starting point complete all as specified and directed
M&L for prepation of old plastered surface and applying two coat of cement based paint over a coat of alkaline resistant priming paint complete all as specified and directed.
Dismantling brick tiles or terracing tiles single layer on roof complete all as specified and directed.
Disconnecting existing tanks exc 250 & n exc 500Ltrs capacity settig aside (or lowering if required) for repairs,cleaning etc and hoisting if required reconnecting and refixing in position complete all as specified and directed.
Dismantling OH water tank of capacity exc 1000ltrs not exc 2000Ltrs complete all as specified and directed.
S & F 2000Ltrs capacity rotational moulded PVC water storrage tank double layer cylindrical including 20mm PVC float valve complete all as specified and directed.
Demolition of mud/mud phuska in roofs any thickness, including plastering and leaping if any and clearing the roof surfaces with wire brushes and removal of mud /mud phuska to a distance exceeding 250 M and n.exc 500M complete all as specified and directed.
Demolition of reinforced cement Concrete of any description and in any position not otherwise specifically provided for (reinforcement cut as required to facilitate demolition) complete all as specified and directed.
M&L cement concrete 1:2:4 type B1 using 20 mm graded aggregates as in roof kerb, mud stops and padding complete all as specified and directed.
Dismantling of floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
M&L 15mm thick screed bed or bedding layer of mortar in CM 1:6 for laying floor finishes complete all as specified and directed.
M & L for non-skid ceramic coloured tiles 7 to 8 mm thick area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
M&L for 10 mm thick rendering in cement mortar 1 : 4 on brick work or concrete surfaces walls for fixing of tiles complete all as specified and directed
M&L for glazed ceramic colour digital tiles (high quality) in vertical surface with highlighter tiles as directed of size 450 X 300 x 7 mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles complete all as specified and directed
M&L for light coloured vitrified tiles (digital high quality), 10 mm thick square/rectangular) jointless, area of each tiles not exceeding 0.36 in floors etc., set and jointed complete all as specified and directed
M&L for 18 to 20mm thick granite of size not less than 1.5sqm of each piece for floor (table rubbed & polished) in floors, jambs, pillars, window cills, plate forms and like in CM (1:4) including pointing in white cement (1:2) ,using marble dust with admixture of pigment to match with shade of granite, complete all as specified and directed
M & L for 20-25mm thick, machine cut, Kota stone slab, as in floors, steps, landing etc. set and jointed in neat cement slurry and pointed in coloured cement to match the shade of slab, including cutting, polishing etc. with over and including 20mm thick screed bed in CM 1:4 complete all as specified and directed
Taking up or down tubing GI 15 mm bore including all fittings complete all as specified and directed by Engineer-in-Charge.
All as per srl item No-32 (here in before) but bore of pipe 20 mm complete all as specified and directed
All as per srl item No-32 (here in before) but bore of pipe 25 mm
All as per srl item No-32 (here in before) but bore of pipe 40 mm
Refixing of 40mm bore old steel tubing and connection in new or old position in wall,ceiling,floor etc complete all as specified and directed.
Refixing 25mm bore old steel tubing and connection in new or old position in wall,ceiling,floor etc complete all as specified and directed.
Refixing 20mm bore old steel tubing and connection in new or old position in wall,ceiling,floor etc complete all as specified and directed
Refixing 15mm bore old steel tubing and connection in new or old position in wall,ceiling,floor etc complete all as specified and directed . Note for Srl No. 36 to 39- old servicable pipe obtained from dismantling shall be re-used after cleaning
S & F 15 mm bore medium grade galvanised steel water tubing with all fittings fixed to wall or laid in floors complete all as specified and directed
All as per item No-40 (here in before) but bore of pipe 20 mm
All as per item No-40 (here in before) but bore of pipe 25 mm.
All as per item No-40 (here in before) but bore of pipe 40 mm.
S&F 1.5 mm thick section aluminium anodized glazed window shutter, styles & rail 44mm x 44mm including all fittings, such as aluminium handle of size 100mm ,two no aluminium hinges of size 75mm each ,two no aluminium anodized tower bolts of size 100mm, with each moving leaf complete all as specified and directed
S&F of frosted/plain glass in squares n.exc 0.5 sqm each panes 4.0 mm thick, as in aluminum window/Ventilator/door, including rubber packing and aluminium beading complete all as specified and directed
S & F of MS bar deformed, TMT 10mm dia and over cut to length, bent to shape including cranking, binding with MS wire of dia not less 0.9 mm dia, complete all as specified and directed
All as per item No. 46 (here in before) but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and directed.
S&F of roller blinds vertical type 100mm wide slats made out of fabric cloth of approved shade fixed as per the instructions of manufacturers, complete all as specified and directed.
S&F of venatian blinds vertical type 100mm wide slats made out of fabric cloth of approved shade fixed as per the instructions of manufacturers, complete all as specified and directed.
S&F 9mm thick (5 no of ply) Plywood, grade BWR, type BB, fixed with screws to brick wall complete all as specified and directed.
S&F 150mm bore PVC pipe (SWR) single socketed in any length with rubber ring joints fixed to wall complete all as specified and directed.
S&F PVC (SWR) bend 150 mm dia any radius complete all as specified and directed.
M&L for wall cladding, laminated wooden type made of high density fibre board (HDF), comprising of tongue and groove interlocking type of planks of 1210 x 193mm size 8mm thick, commercial grade, abrasion resistance of AC-III category, with and including all fixing material i.e chemical adhesive, base strip /fillets etc veneered and matching top beading etc complete all as specified and directed.
M&L formwork for fair finish surface of concrete to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. complete all as specified and directed.
M&L Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed.
M&L RCC type B-1 1:2:4 (20mm graded agg) Beams, cantilevers, bressummers,lintels over 1.5m span complete all as specified and directed.
M&L RCC type B-1 1:2:4 (20mm graded agg) Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
S & F of MS TMT deformed bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming to, complete all as specified and directed.
S & F of MS TMT deformed bar, 6 to 8 mm dia and over cut to length, bent to shape including cranking, binding with MS wire of dia not less 0.9 mm dia, complete all as specified and directed.
S&F in repairs aluminium partition wall of aluminum section 100mm x 44mm x 1.5mm thick frame rectangular section area of each panel n exc 1.0 sqm of 9mm thick prelaminated board in bottom panel or whole panel and 5.5mm thick frosted glass in top panel with rubber lining and aluminum beading around length including necessary fixing arrangement for bottom and top member of aluminum frame in floor/PCC/Brick work as per site requirement with rawl plug etc, including chromium plated steel screws 60cm centre to centre all as specified and directed by Engineer-in-Charge (Note : Cost of PVC panel or prelaminated board and sheet glass shall deemed to be included in the rate quoted for this item )
S&F aluminium powder coated glazed three track sliding window of frame 100x 44x1.5 mm size, three track sliding channel of size 95 x 42 and sliding shutter of section , 40mm x 19mm including 3mm thick glass pane in two track shutterand in one track Stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples, all fittings, such as aluminium handle of size 100mm and locking arrangements with each moving leaf complete all as specified and directed.
S&F toughened (plain / frosted type) glass frameless door with fixed portion, of 12 mm thickness, including cutting holes, edges rounded and etching works etc and all kind of SS patch fitting & fixture, spider patch etc, complete all as specified and directed.
S&F toughened (plain / frosted type) glass frameless window with fixed portion, of 12 mm thickness, area of window upto 4.00 sqm in single piece glass including cutting holes, edges rounded and etching works etc and all kind of SS patch fitting & fixture, spider patch etc, complete all as specified and directed.
S&F of stainless steel handle 450 mm long fixed to 12 mm thick toughned glass door with and including all fixing accessories i. e. bolt washer, adhesive etc, complete all as specified and directed.
S&F of SS door lock, glass to glass type, suitable for 12 mm thick frameless toughned glass door with and incl all fixing accessories i. e. bolt, washer, screw, adhesive etc of suitable size, complete all as specified and directed.
S&F in repair of Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box,main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed, complete all as specified and directed.
M&L 18 mm thick Medium density fibre board, exterior grade, fixed as in framework for cupboard and cupboard shutters including leeping/beading fancy type with screws complete all as specified and directed.
S&F soft closing clip on hinge, full / half overlay type, of stainless steel, complete all as specified and directed.
S&F 100 mm size extruded brass handles, fabricated type polished complete all as specified and directed.
S&F multi purpose lock 50mm size with triple keys, suitable for cup board door/drawer , complete all as specified and directed.
M&L for wooden flooring, laminated wooden type made of high density fibre board (HDF), comprising of tongue and groove interlocking type of planks of 1210 x 193mm size 8mm thick, commercial grade, abrasion resistance of AC-III category, with and including all fixing material i.e chemical adhesive, base strip /fillets etc veneered and matching top beading etc complete all as specified and directed.
S&F cup board / drawer knob of stainless steel with matt finish fixed with screw, complete all as specified and directed.
S&F of SS (Gd-304) brackets, angles, hollow tubes, flats etc of any shape and size with & including SS screws / fasteners etc and all kind of machine works i.e. cutting, welding, bending, moulding, grinding, polishing, buffing etc to get the required shape like (independent piece or framing work) and size, fixed to any position and at any surface etc,complete all as specified and directed. (Note : All fixtures and fittngs should be of stainless steel)
S&F in repairs of stainless steel sink, 1.00 mm thick for kitchen or laboratory with plug, waste pipe, washers, including mild steel brackets, connecting union etc overall approx size 550 mm x 450 mm with approx bowl size of 500 mm x 375 mm x 200 mm etc, complete all as directed. Make - Nirali / Neelkanth/ Bluestar
S&F 3mm thick aluminium coated panel (ACP Sheet) including necessary clips, rubber packing & aluminium beading (aluminium frame ) complete all as specified and directed.
M&L sensor for operating toughened glass sliding door with complete fittings and sliding accessories complete all as specified and directed.
M&L for surgical scrub station made of stainless steel 304 gde with sensor operated 02 nos surgical tap / mixer (weight of scrub station 110 Kg to 120 Kg), fitted at site with complete fittings and making outlet and connected complete all as specified and directed.
S&F telescopic type ball bearing slide & runner, suitable for drawers, complete all as specified and directed.
S&F in repair for 100 mm size stainless steel handles, matt finish, complete all as specified and directed.
M&L for complete removal of existing treatment on walls surfaces and providing a layer of 1-2 mm thick wall care putty on plaster surfaces of wall and preparation to receive plastic emulsion/distemper etc, complete all as specified and directed.
M&L for applying two coat of oil bound distemper with roller on wall surface over a coat of primer, complete all as specified and directed.
S&F Solid PVC Wall Lining consisting of 5mm thick wood grain finish colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing complete all as specified and directed.
S&F 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing. complete all as specified and directed.
M & L for making designer cornices of 75 mm x 75 mm by POP and applying two or more coats of plastic emulsion paint to match colour with gypsum board false ceiling, etc.,complete all as specified and directed.
S&F 32mm bore CPVC pipe for carrying wash basin waste water with all fittings and fixture complete all as specified and directed.
M&L 0.9mm thick decorative laminate type 1 of surface finish, fixed with approved adhesive smooth surface finish, wooden texture colour and pattern, including taking down of old laminates,complete all as specified and directed.
S & F in repairs 1mm thick Steel rolling shutters, with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete; push pull or manual type complete all as specified and directed.
S & F in repair 1mm thick Steel rolling shutters, but gear operated type with bevel gear box and crank handle, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete; push pull or manual type
M&L for applying two or more coats of french polishing on wooden surface of any description/size with and including preparation of old painted surfaces, complete all as specified and directed.
M&L cutting chasing pinning in brick work making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth complete all as specified and directed.
M&L, Priming roof surfaces and applying water proofing treatment over roofs comprising of the following complete all as specified & as directed:- (a) Applying oil bound bituminous primer at the rate of 0.4 Ltrs/Sqm as per IS 3384-1986 on prepared surfaces. Surface shall be kept free till the moment, the primer is impregnated and the solvent oil in primer is evaporated. (b) Applying one coat of hot straight run bitumen @ 1.20 Kg/Sqm of grade 30/40 confirming to IS-73 (Grade S-35). (c) Laying 3mm thick APP polymeric water proofing membrane of weight not less than 3.6 kg/sqm, black finish reinforced with non woven polyster matt, with a thermo fusible finish, torching overlaps with a propane or a butane gas torch, with a overlap of 75mm at sides and 100mm at the ends and sealing including applying a coat of cold emulsion bituminous primer all as per manufacturer's instruction including preparation of surface. (d) Applying one coat of hot straight run bitumen grade 30/40 (Grade S-35) conforming to IS-73 @ 1.20 kg/Sqm. Make: "Moply FP" manufactured by STP Texsa Ltd or Hyper Plas (Polyester) manufactured by M/S IWL Ltd or "Shaliplas"ter) manufactured by M/S Capital Steels and Chemical Pvt Ltd or Makpolyplast manufactured by M/S M K Patro as approved by GE. Note :- The water proofing treatment shall be got carried out by the manufacturer or their authorised applicators. The contractor shall give 10 years guarantee for effectivenss of water proofing treatment, 2.5% of work done amount of this item shall be retained from contractors payment for a period of 10 years reckoned from date of physical completion of this work, or inlieu contractor may deposit bank FDR for the said amount for 10 years which shall be released by GE on expiry of satisfactory completion of 10 years period.
M&L for pre-cast PCC tiles machine pressed of size 250mm x 250mm x 20 - 25mm thick over and including 15mm thick screed bed in Cement Mortar 1 : 6 and joints grouted flush in cement mortar 1:3 mixed with WPC as per manufacturer instruction complete all as specified and directed.
M&L for guniting of spalled / corroded reinforced cement concrete surface, on vertical or overhead position, comprise of chipping of spalled and loose concrete; cleaning rust from reinforcement by sand blasting; scrubbing down concrete surface with wire brushes; cleaning with water; allowed to dry and applying a layer of zinc rich epoxy primer as anti rust on all exposed reinforcement followed by a layer of bonding coat of approved epoxy adhesive on complete exposed surfaces of concrete to be gunited; applying two layers of guniting over steel welded wire mesh having 4 mm dia of wire and aperture 75 mm, total thickness of gunite not exc 25 mm thick (average thickness) in cement mortar 1:2 using OPC 53 grade cement duly mixed with polycrete admixture @ 2% by weight of cement or as per manufactures instruction and finally applying cement plaster over gunite surface of required thickness to give even, uniform & smooth finish conforming to proper geometrics in cement mortar (1:3) to match with the existing surface as in sides and soffits etc of slabs, chajjas, fins, fascias, parapets, lintels, columns and beams etc with and incl necessary scaffolding, shuttering, chases to brick work or RCC members etc, and applying two coat of weather proof exterior emulsion paint over a coat of primer complete all as directed. Note : (i) This item will be executed up to G+4th floor height with proper safty instructions). (ii) Reinforcement shall be measured and paid seprately under respective item of this schedule.
S&F of white colour, 1st quality vitreous china washdown water closet (pedestal pattern) white (excluding fixing of flushing cistern & flush pipe) including fixing in floor complete all as specified and directed.
S&F of 1st quality vitreous China white colour wash hand semi under counter type of size 65 x 50 x17 cm , complete all as specified and directed.
S&F in repairs brass chromium plated tubular towel rail, 20mm dia, (Double rail type) 60cm long between flanges complete all as specified and directed.
S&F in repair brass CP angle cock 15 mm bore with flange complete all as specified and directed.
M&L hard core of broken bricks guage n exc 63mm deposited spreads and leveled in layer n exc 15cm thick watered and rammed to a true surface complete all as specified and directed.
M&L 75mm thick cement concrete type C2 1:3:6 (40mm graded stone agg) as in plinth protection & path complete all as specified and directed.
M&L for cutting into existing manholes for inserting SWG / RCC pipe upto 300mm dia and making good to pipe and rendering cutting out existing benching for and forming branch channel (1/2 round or 3/4 section ) in cement concrete 1:2:4 type B-I, smooth finished and reforming benching as required, complete all as specified and directed.
S&F 100mm dia cast iron nahani trap with grating incl jointing to waste pipe fitted in cement concrete type B1 (1:2:4) complete all as specified and directed.
S&F solid PVC door frame of size 50x47mm made out of 5mm but wood grain printed PVC sheet used instead of Plain colour PVC sheet & edges will be painted to match with printed sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing
S & F Factory Made Solid PVC moulded door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm wood grain printed PVC sheet on back face, supplying & fixing in frame at site as per specification & drawingl etc complete all as specified and directed.
S&F stainless steel butt hinges of size 100 mm ISI mark complete all as specified and directed.
S&F aluminium anodized handle 150mm long ISI mark complete all as specified and directed.
S&F aluminium tower bolt 150mm long ISI mark complete all as specified and directed.
S&F aluminium sliding door bolt 250mm long ISI mark complete all as specified and directed.
S&F in repairs vitreous China white urinal flat back (Long) 600 to 680mm x 400mm to 420mm x 375 to 380mm with 32mm dia CP casted bottle trap, 32mm dia brass CP dome waste, 32mm dia brass CP spreader union for discharge pipe 32mm complete with necessary fittings complete all as specified and directed.
S&F in repairs of 15mm dia Brass CP connection and 45cm long with 2 Nos brass check nuts with washers for geyser, complete all as specified and directed.
M&L in repair brass CP angle stop valve (fancy type) 15 mm bore with flange complete all as specified and directed.
S&F in repair of 15mm Bib taps, fancy type cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed chromium plated, complete all as specified and directed.
S&F in repairs fancy type Pillar taps, cast copper alloy, with capstan heads, chromium plated,screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed.
S&F SS glossy finish grating of square shape, overall size of 150x150mm with hinge type openable jali of 100 mm dia size with and including fixing with cement mortar to floor/nahani traps etc, complete all as specified and directed.
M & L in repairs for cast iron floor trap of 75 mm outlet plain with grating including jointing to waste pipe in run lead fixed in cement mortar complete all as specified and directed.
S&F 100 mm size mild seel butt hinges medium weight cold rolled complete all as specified and directed.
S&F of white colour, vitreous china washdown water closet pan (pedestal pattern) fancy type including built in vitreous china flushing cistern dual flush type of capacity 10 litres including PVC white seat cover, complete all as specified and directed.
S&F 150mm size aluminium alloy handles,cast type,anodised complete all as specified and directed.
S&F 300mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet,cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium complete all as specified and directed.
S&F in repairs gun metal, globe or gate valve with iron wheel, screwed both ends for iron pipe suitable for 20 mm bore iron pipe complete all as specified and directed.
S&F in repairs gun metal, globe or gate valve with iron wheel, screwed both ends for iron pipe suitable for 15 mm bore iron pipe complete all as specified and directed.
S&F in repairs gun metal, globe or gate valve with iron wheel, screwed both ends for iron pipe suitable for 25 mm bore iron pipe complete all as specified and directed.
S&F in repairs gun metal, globe or gate valve with iron wheel, screwed both ends for iron pipe suitable for 40 mm bore iron pipe complete all as specified and directed.
S&F in repairs vitreous china water closet (Padestal pattern ) white (excluding fixing flushing cistern & flush pipe) including fixing in floor complete all as specified and directed.
S&F in repairs vitreous china wash basin, white colour, flat back type, of approx size 580 x 450 mm (for hospital use) including waste coupling, wall bracket, waste pipe of suitable size etc, complete all as specified and directed.
S&F in repairs of urinal partition of vitreous china white colour of size310 x 700mm and including all fittings and accessories, duly fixed to walls, complete all as specified and directed.
S&F in repairs vitreous china water closet semi-pedestal pattern (Anglo-Indian Type white (excluding fixing flushing cistern & flush pipe) including fixing in floor complete all as specified and directed.
S&F in repairs solid toilet seat cover moulded frame high grade thermoplastic complete with polymer fitting white colour complete all as specified and directed.
S&F in repair 10 liters PVC valve less syphonic action type flushing cistern, low level white with inlet, ball valve, float and handle including bracket and flush pipe to squatt pattern closet including all joints and making good to the floor complete all as specified and directed.
S&F in repairs of 15mm dia PVC connection 45 cm long, complete all as specified and directed.
S&F in repairs of wash basin mixer, with out pop up waste system, long body, made of cast copper alloy, chromium plated fancy type, suitable for 15 mm bore pipe, complete all as specified and directed.
S&F in repair toilet paper roll holder with flap made of cast copper alloy, chromium plated, complete all as specified and directed.
S&F in replacement brass chromium plated Tubular towel rail 20mm dia, 60cm long D type complete all as specified and directed.
S&F in replacement of bottle trap 32 mm size with 250 mm long wall connection pipe and wall flange made of cast copper alloy, chromium plated fancy type, complete all as specified and directed.
S&F in replacement of two way bib cock suitable for 15 mm bore water pipe, with & including wall flange made of cast copper alloy, chromium plated fancy type, complete all as specified and directed.
S&F in replacement of handshower (health faucet) with 1.20mtr long PVC flexible tube, wall hook made of cast copper alloy, chromium plated fancy type, complete all as specified and directed.
S&F in replacement PVC made multipurpose cabinet with front door looking mirror of overall minimum size 350 x 450 mm, ccomplete all as specified and directed.
M & L in repairs for Cast iron floor trap of 100 mm outlet plain including jointing to waste pipe in run lead fixed in cement mortar complete all as specified and directed.
Taking down CI pipes of any size or pattern including all fitting fixed to wall, floors, etc complete all as specified and directed.
S&F for 100mm bore cast iron soil waste and vent pipes (sand cast pipes) in any length fixed with lead joints fixed to walls, complete all as specified and directed.
S&F 100mm bore cast iron soil waste and vent pipe (sand cast pipes) in any length with or without ears fixed with cement joints laid in floors or in trenches complete all as specified and directed.
S&F 75mm bore cast iron soil waste and vent pipe (sand cast pipes) in any length with or without ears with cement joints laid in floors or in trenches complete all as specified and directed.
S&F for 75mm bore cast iron soil waste and vent pipes (sand cast pipes) in any length with lead joints fixed to walls, complete all as specified and directed.
S&F for 100mm bore cast iron branch pieces, single (equal or unequal) ordinary or inverted (spigot or socket type) with parallel branches complete all as specified and directed.
S&F of cast iron 'P' trap or 'S' trap of 100mm size as per IS:1729-2002, ISI marked, fixed with lead joints, laid in floors, complete all as specified and directed.
S&F cast iron bends,Tee (any radius) diminishing pieces or tapers (larger bore measured) of 100mm bore of pipe fitted with oval access doors complete all as specified and directed.
S & F in repair of 100mm dia Stack clamps out of 50mm by 5mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof complete all as specified and directed.
S & F in repair of 75mm dia Stack clamps out of 50mm by 5mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof, complete all as specified and directed.
Demolition of un-reinforced cement concrete in ground floors and pavings not exceeding 15 cm thickness. (Below or above ground level) and removing rubbish off premisses to a distance n exc 500 m complete all as specified and directed.
M&L PCC 1:5:10 type E-2 (using 40 mm graded stone aggregate) in sunken floor complete all as specified and directed.
M&L for rendering 15 mm thick in CM 1:4 on brick or concrete surfaces using integral water proofing compound (3% by weight) for floor and sides of wall complete all as specified and directed. (Note :Water proofing compound shall be measured for paid separately as supply only).
M&L for sealing of pipe penetration of toilets core cutting & sunken slab treatment in following stages :- Supply and apply solvent free, moisture insensitive epoxy resin based patch repair putty Sikagrade-694F (I), yield : 0.6 ltr/kg, suitable for submerged condition having compressive strength of 40N/mm2 (1day) according to IS 9162-1979 on pipe penetration surface. The putty shall be applied to a groove thickness of minimum 20mm on pipe penetration joints to concrete. Penetration of surface of sunken portion and M & L for glass fibre reinforced acrylic modified cementitious coating system as Top coat : Sika Top Seal-107@ 1.5 kg/m2 over reinforcement : Sika Fab-1 over base coat : Sika Top Seal-107 @ 1.5 kg/m2 etc all as specified and directed. System should have compressive strength : 20 N/mm2 ; bond strength : 2.0 N/mm2 complete all as specified. Note : (i) Entire work shall be carried out through Manufacturar or his authorised representative. (ii) The contractor shall furnish a 10 years warranty for effectiveness of waterproofing treatment and the period shall be reckoned from the next day of actual date of completion of work. (iii) An amount of 2.5% of total quoted amount against this item shall be retained, out of the final bill amount as security Deposit, against 10 years water proofing effectiveness and the same shall be released only after the expiry of guarantee period. The contractor may also furnish fixed deposit receipt/BGB in lieu of the sum to be retained as security.
M&L for 25 mm thick PCC 1:2:4 type B0 (Using 12.5mm graded stone aggregate) as in flooring with smooth surface finished complete all as specified and directed.
M&L 15 mm thick cement plastering in cement mortar 1:4 finished even and smooth on fair faces of brick walls complete all as specified and directed.
M & L preparation of newly plastered surfaces and applying two coat of cement base paint over a coat of alkaline resistant priming paint complete all as specified and as directed.
Demolition of brick work built in cement mortar including all quoins, arches, pillars, etc but excluding ashlar facing, dressed stone work and precast concrete articles, complete all as specified and directed.
M & L for brick work with sub class B bricks old size, straight or curved on plan to any radius in half brick thick walls built in CM 1:4, complete all as specified and directed.
M & L for brick work with sub class 'B' bricks straight or curved on plan exc 6 m mean radius built in CM 1:6 etc, complete all as specified and directed.
Taking down cement plaster of any description on brick or stone walls etc including racking out joints hacking for key scrubbing down with water etc complete all as specified and as directed.
M & L for 15mm thick rendering on fair/ other than fair faces of brick / concrete surfaces in cement mortar 1:6 and finished even and smooth without using extra cement , complete all as specified and directed.
M&L for preparation of newly plastered surfaces of walls and applying two coats of oil emulsion distemper over a coat of alkali resistant primer complete all as specified and as directed
Taking down chowkhat or frames with shutter (without taking off shutter from frame) area n exc 1.50 Sqm and removal from site complete all as specified and directed.
Taking down chowkhat or frames with shutter (without taking off shutter from frame) area exc 1.50 Sqm but n .exc 4.00 sqm each and removal from site complete all as specified and directed.
S&F, aluminium anodized powder coated chowkhats of 100x44x1.8mm section with rebate complete frame complete all as specified and directed.
M&L 5.5 mm thick frosted glass including necessary clips, rubber packing & aluminium beading (aluminium frame ) complete all as specified and directed.
Supply fabricating and fixing of aluminium door shutter powder coated of extrusion aluminium section, Vertical style of door shutter of size 85mmx44.45mmx1.8mm thick. Top, middle and bottom rail of size 85mmx44.45x1.8mm thick and fixing 5 mm thick plain/frosted glass of Modi guard/Atul or prelaminated particle board 9 to 10mm thick of make Kit Ply with aluminium beading and rubber gasket/beading as directed. One mortice lock for aluminium tower bolts of 200 mm size, 2 nos of American type handle of size 250 mm and 4 Nos of aluminium powder coated hinges of size 100 mm for each door fixed with rawl plug including rectification of floor/wall to match the existing surfaces all as specified and as directed by Engineer-in-Charge at site. ( Note :- Cost of sheet glass Plain/frosted/particle board shall be measured and paid seprately )
M&L for Excavation in trenches, exc 1.5 m but n exc 3.0m depth and 1.5m wide, getting out in hard and dense soil , complete all as specified and directed.
M&L for factory made RCC drain cover with cover frame comprising of 75 mm thick cover, area of each cover slab exc 0.5 Sqm & n exc 1.00 sqm including provision of hot dip galvanized lifting hook for lifting overall cover with suitable size angle iron frame, RCC cover of M30 or higher grade concrete by vibro compression process, medium duty, confirming to IS-12592 including fixing on manhole, demolition of existing cover with cover frame and removal of debris from site complete all as specified and as directed.
M&L for Returning/ filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and as directed.
M&L for Removing excavated material exc. 250 m but n exc. 500 m and depositing where directed ,complete all as specified and as directed.
M&L for 300 mm bore reinforced concrete pipes, class NP2, laid and jointed with and incl collars, complete all as specified and directed.
M&L for PCC 1:3:6, type C-2 using 40 mm graded stone aggregate as in concrete bed to drain pipe including packing under and hunching against the all sides of pipe upto 300 mm bore, complete all as specified and directed.
M&L for Cutting holes in brick walls built in cement mortar mud mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required complete all as specified and directed.
M & L Cement concrete type B2 1:2:4 (40 mm graded aggregate) in foundations, filling and mass concrete complete all as specified and directed.
Dismantling of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and directed.
M&L for exposed GI frame/grid system duly powder coated for module size of 600 x 600 mm suitable for lay-in aluminium / mineral fibre ceiling tiles, having main T runner of 24 mm size, suspended at 1200mm C/C and cross T runner of 24 mm size, suspended at 600mm C/C with interlocking arrangements to form grid of 600 x 600mm, perimeter runner/channel of 15 mm size, main and cross T runner supported by 4mm dia GI rod from slab / Roof, wall angle etc with and including all fixing accessories complete all as specified and directed.
M&L for metal false ceiling, lay-in type, 0.5 mm thick, having tegular edge profile, duly powder coated, perforated type with glass fibre acoustic fleece, suitable for false ceiling grid/frame module of 600 x 600mm size, complete all as specified and directed. (Note : The grid /frame shall be measured and paid for separetly.)
Supply & fixing of false ceiling in step (s) comprising of 12 mm thick Gypsum board including GI frame work for seamless ceiling made of GI perimeter channel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/ intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with GI cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 M length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre including two coats of plastic emulsion paint complete all as specified and directed.
Supply only integral liquid water proofing compound, mixed in CM as per manufacturer instruction, complete all as specified and directed.
S&F 200X200 mm high quality toughned glass corner shelf made of 5mm thick of glass complete all as specified and directed.
Taking down shutters of any description exc 1.0 sqm and n exc 2 sq. m each and removal from site complete all as specified and directed.
Taking down shutters of any description exc 2 sq. m each and removal from site complete all as specified and directed.
S & F 40mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type both face is covered with decorative or lamination face veneer with lipping/frame to match complete all as specified and directed.
M&L for applying two or more coats of french polishing on wooden surface of any description/size with and including preparation of new surfaces, complete all as specified and directed.ted.
Demolition and breaking up drain pipes(Salt glazed ware Ac or reinforced concrete) of 200 mm internal dia of pipe set in cement mortar complete all as specified and directed.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., complete all as specified and directed.
M & L for 5.5mm thick plain glass including necessary clips, rubber packing & aluminium beading, complete all as specified.
M&L for 18 to 20mm thick granite of black colour in single piece of any size required at site (table rubbed & polished) as in plate forms and like in CM (1:4) including pointing in white cement (1:2) ,using marble dust with admixture of pigment to match with shade of granite, complete all as directed.
M & L for cutting for door viewer window of size 150x150mm in flush shutter and fixing of 5.5mm thick plain glass fixed with wooden beading complete all as specified and directed
S&F steel windows/vents shall be of “ECO” series 4000 of M/S NCL alltek seccolor Ltd. Or equivalent made of cold rolled steel sheet formed galvanized prepainted/powder coated steel sections as per IS-513, 0.6mm thick galvanized as per IS-277 with zinc of 120 gm/sqm and primer coated with epoxy primer of 5-7 microns thick, finish painted with a polyster based paint 12-16 micron thick or powder coated and back coated with 5-7 microns thick alkyl backer. The sections are to be cut to length metre jointed with standard corner bracket made of PVC and mullions are to be fixed with standard mullions caps. Windows and vents shall be fixed in masonry before plastering by means of hold fasts made of 3mm CRCA 100mm long screwed to window outer frame having self expanding sleeves tail fixing shall be done all as per manufacturer’s instructions and as shown on drawings.
Description of Work / Item(s)
Amount
M&L for taking down old unserviceable point wiring including existing surface/concealed conduit after disconnection of electric connection from main DBs (light, fan, socket or power point) complete with accessories such as switches, ceiling rose, pendent holder, regulator and socket etc and removing the material from site and making good the disturbed surface of wall / floor/ ceiling etc as original existing surface i.e. brick work, plastering, white colour washing complete all as specified and directed.
All as per srl item No. 02 (here in before) but point wiring for one socket outet point 5 amps on the same board.
All as per srl item No. 02 (here in before) but point wiring for one socket outet point 5 amps on the independent board.
All as per srl item no. 02 (here-in-before) but with 2.5 sq mm FRLS copper wire with 2.5 Sqmm FRLS copper earth wire for 15 Amp power point on Independent board.
Material and labour in replacement of Sub main wiring with 2 run of 4 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked, drawn in and including cutting and chasing,and also PVC conduit suitable dia as per SSR part-I with medium grade including 4 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked as earth wire, connected with thimble from main DB to sub main DB complete all as specified and directed. Note : 1. The two run of 4 Sqmm wire, one run of 4 Sqmm as earth wire and 1 run of PVC conduit will be measured as one unit.
All as per srl item no. 6 (here-in-before) but with 2 run of 6.0 sq mm FRLS copper wire with one run of 6.0 Sqmm FRLS copper cable as earth wire complete all as specifed and directed.
All as per srl item no. 6 (here-in-before) but with 2 run of 10.0 sq mm FRLS copper wire with 10.0 Sqmm FRLS copper cable as earth wire.
Supply & fixing Modular switch 6 Amp, 1 way, 1 module size complete all as specified and directed.
Supply and fixing Modular switch 16 Amp, 1 way, 1 module size complete all as specified and directed.
Supply and fixing Modular socket 6 Amp, 3 pin, 2 module size complete all as specified and directed.
Supply and fixing Modular socket 6/16 Amp, 3 pin, 2 module size complete all as specified and directed.
Supply and fixing Modular Fan regulator step type, 120 watts, 2 Module size complete all as specified and directed.
Supply and fixing Ceiling rose, PVC polycarbonate body isolated body, 3 terminal, 240 volts, 5 Amps complete all as specified and directed.
Supply and fixing MCB protected modular AC/Geyser box 3 module complete with and including 6 pin socket 25 amps, plug top, modular cover plate, mini MCB SP 25 Amp C Curve capacity and PVC gang box etc, complete all as specified and directed.
M&L for earthing complete in replacement with galvanized steel earth plate electrode 60cmx60cmx 6 mm thick burried directly in ground, earth pit not less than 2.25 Mtr deep and top edge of plate not less than 1.25 mtr below ground level and connected to GI earth lead wire 4 mm dia fixed by means of nuts bolts etc including light grade GI pipe 15 mm dia bore for protection of GI wire 4mm dia, connected to earth test point surrounded by packed alternative layers of charcoal and common salt 15 cm thick all around top, GI pipe 20 mm dia with GI funnel and bottom complete all as shown in plate No 3 to the earthing test point all as specified and indicated including provn of PCC chamber 1:3:6 using 20mm graded stone aggregate, 50mm thick cover with RCC 1:2:4 type B-1 using 8 mm dia TMT bars @ 100 mm C/C both ways as in reinforcement, necessary excavation, earthwork, returning filling and testing on completion etc complete all as specified and directed.
All as per srl item No. 16 (here in before) but using 32mmx6mm size GI strip and light grade GI pipe for protection of GI strip 40mm bore
Supply and fix in replacement bed head light fitting including 1x10 Watt LED, 1x20 watt LED, 1x5 watt LED lamp made of powder coated CRCA sheet & acrylic cover including 2 metre lenth of pendent with 03 Nos switches for each light complete all as specified and directed.
S&F in replacement LED tube light fitting 20 watt (CW) , 4 feet long in extruded aluminium batten with high efficient LEDs available in milky diffuser and Color Rendering Index (CRI>70), IP20, correlated Color Temparature (CCT- 5700K to 6500K) , PF>0.9 and Voltage rated 220V to 240V complete all as specified and directed.
S&F in replacement of recessed mounting LED light fitting (flat panel) 2' x2' with high efficeint LEDs and Glare free and opal diffuser of 36 watt (CW) including fixing accessories likes strip clips etc and Color Rendering Index (CRI>70), IP20, correlated Color Temparature (CCT- 5700K to 6500K) , PF>0.9 and Voltage rated 220V to 240V etc complete all as specified and directed.
S&F in replacement recessed mounted LED light fitting 15 watt(CW/WW) slim round down lighter with high efficient LEDs and glare free opal diffuser including fixing accessories likes strip clips and Color Rendering Index (CRI>70), IP20, correlated Color Temparature (CCT- 5700K to 6500K) , PF>0.9 and Voltage rated 220V to 240V etc complete all as specified and directed.
M&L taking down carefully and re-fixing only serviceable light fitting any type after finishing the civil work on wall or roof including connecting wire upto 1 mtr long complete all as specified and directed.
M&L for taking down carefully and any type and sweep of fan and re-fixing on same position with cleaning and painted with existing matching colour complete all as specified and directed.
M&L for taking down carefully and any type of fire alarm detector from ceiling and re-fixing on same position with cleaning and tested complete all as specified and directed.
S&F in replacement Distribution Board double Door made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, flushed mounting, SPN 12 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCB’s and isolators etc and making all necessary connections, incl cutting & chasing and making good the surface as per existing complete all as specified and directed. (Note: MCBs shall be measured and paid seperately.
All as srl item no 25 (here in before) but 8 way type SPN.
All as srl item no 25 (here in before) but SPN 04 way type.
S&F in replacement MCCB Incomer distribution board double door vertical type made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating, TPN 8 way, 415 volts with copper bus bar rating 250 Amps for each phase, dust and vermin proof and IP 43, IK-09 protection for provn of MCCB, MCBs as required at site incl necessary cutting chasing and making good the disturbed surfaces complete all as specified and directed.
S&F in replacement of MCCB, 415 volts, four pole of capacity 125 Amps, 25 KA, ICS = 100% ICU, with Thermal - Magnetic Release, including spreader terminals, phase barriers, thimbles of suitable size etc and making electric connections complete all as specified and directed.
All as per srl item No 29 (here-in-before) but 160 Amp, 25 KA capacity.
S&F of MCB in replacement C curve type, 10 kA, 6-32 Amp, single pole, 10 KA with over load and short circuit protection complete all as directed.
All as srl item no 31 (here-in-before) but of 40-63 amps capacity 10 KA.
All as srl item no 31 (here-in-before) but of 40-63 amps capacity SPN type, 10 KA.
M&L in replacement of Fastrack RA 035 ceiling Column Rigid ICU pendant with standrad accessories powder coated aluminium with 8 Nos of electric switch socket with provision of 4 oxygen, 3 suction, 2 compressed air and 1 N2O outlets, IV Tree system available with minimum 4 points complete all as specified and directed.
Taking down carefully existing aluminium /GI strip of any size fixed in position as lightning conductor from roof/wall and buried in ground including making good the disturbed surfaces etc complete all as specified and directed by the Engineer-in-Charge.
Taking down carefully existing air termination rod any type and size from roof complete all as specified and directed by the Engineer-in-Charge.
Fixing only aluminium/GI strip of any size obtained from item No. 1 above after necessary repairs (like removing denting/bend rejoining tightening properly by GI bolts and nuts securing, tightly by MS clamps of suitable size for roof/conductor/down conductor above ground level including jointing properly by existing GI/Aluminium strips, air termination rod and insulators) complete all as specified and directed by the Engineer-in-Charge.
Fixing only air termination rod obtained from item No. 2 here-in-before securing tightly to poles/GI pipe on roof strip by clamps of flat iron 25x3mm making connections with aluminium conductors and down conductors complete all as specified and directed by the Engineer-in-Charge.
Description of Work / Item(s)
Amount
Supply, & installation, testing and commissioning out door type, floor mounted step down transformer, 11KV/ 433 Volts ( At no load) AC 3 ph, 50 Hz, energy efficient level - 2 confirming to IS 1180 of 2014 (ISI maked and BEE Approved), capacity1600 KVA CRGO with M4 grade, core type, double copper wound, oil immersed, naturally cooled, oil natural- air -natural (ONAN), Class A insulation with external cooling tubes, delta connected on primary side (HV) and star connected on secondary side( LV) in accordance with vector group Dyn- 11 with natural brought out on secondary side (LV) and having tappings at +/- 2.5% to +/- 5% on HV side to be changed by means of hand operated off load tap changer gear. The maximum temprature rise should not exceed 40 degree C in oil and 45 degree C in HV /LV windings when measured by resistance method after countinuous full load run on an ambient temp of 50 degree C and shall also comprise of the following:- (a) 01cable box chamber on HV side( primary) consisting of 03 Nos poreclin bushing with copper rods complete with nuts and washers, with 01 No cable gland suitable for existing cable. (b) 01 box on LV side( secondary) consisting of 04 Nos copper bus raisers as per load including adopter box complete with cooper braided felxible jumper for connecting with aluminium busbar truncking (BBT) of capacity 2500 amps. (c ) Oil conservator tank with filter type drain plug and oil level gauge. (d) Dehydrating brether with first fill of silica gel. (e) Explosive vent, thermameter pocket on tank cover, oil level guage, oil drain filter valve, lifting hucks, oil filling hole with cap/ plug with connection plate complete. Air release valve plug at four Nos plate soil cast steel detachable rollers.
(f) 01 No 100 mm dia, dial type thermometer, vapour pressure type, having range 0-120 degree C with metal guard having maximum perimeter temperatre reading indicator with resetting device. (g) 02 Nos earthing terminals on tank cover to facilitate fixing of 50 x6 mm GI earth strip for earthing of body. Rating plate and terminal marking plate. (h) Extra bushing for natural, in the LT cable box for providing independent set of earthing for natural. (j) First fill of new and unused transformer oil, IS- 335 marked (make: savita / Power Oil) filtered and tested up to 60 KV die electric strength at 2.5 mm air gap between testing electrodes. (k) Providing adequate size and Numbers of channels, embedded in flour, for movement of transformers. (l) Buchholtz relay complete with electric connection up to relay - 01 No (m) Provn of new platform with suitable working space for inspection as per manufacturer specification and drawing having bearing power more than 6.5 ton for 1600 KVA transformer including plastering & whitewash including demolition of existing platform.
Supply, instaling, commissioning and testing complete of Manufacturer or OEM (original Eqpt Manufacturer) Manufactured and tested static Diesel Engine driven generating set comforming to IS 3046 /BS-5514 & IEC-60034 radiator cooled with AMF panel capable of delivering 1500 KVA (1200KW) or nearest higher rating 415 volts (AC 3 Phase, 4 wire system of supply), 50 Hz to operate at a powers factor of 0.80. The DG set shall consist of a diesel engine coupled through flexible coupling to a matching alternator and mounted on dunlop metallastik foundation pads on a common base frame and thereafter installed in the CPCB approved acoustic enclosure ( the complete set confirming to and test certified as per CPCB norms and as specified) all as specified with control panel standardised by manufecturer, fuel tank with mounting arrangement and inlet, outlet, return oil arrangement, , flexible exhaust pipe complete incl necessary PCC foundation as per manufecturere instructruction and shall comprise of the fwgs:-
(a) Engine (Prime Mover): Diesel Engine 1500 RPM, of suitable HP as recommended by by manufecturer but not less than 1735 BHP( At NTP) radiator cooled turbo charged air cooled, 2 x165 AH 12 volts maint free batteries, start complete with flywheel and all standard fittings/ fixtures as per manufecturing practice incl suitable engine control panel with techometer, lub oil temp and pressure guage, water temp gauge, frequency meter (Digital type) ( incl safety shutdown contents) and also incl self starter, dynamo, fuel tank etc. Make: Cummins / Kirloskar/Greaves Ltd. (b) Alternator : AC alternator, self excited, self regulated, self ventilated, brushless design, confirming to ISO 3046/BS5514 & IEC 60034, 3 phase , 415 volts, 4 wire rated line current 2086 amps for output PF 0.8 , 1500 RPM , insulation class 'H' 'enclosure IP 23 complete with AVR with +/- 1% voltage regulation, directly coupled to and matched with above engine including suitable capacity of adopter unit with flexible copper braided jumper for rasing of busbar truncking . (c) Dunlop metallastik anti vibration pad for mounting engine -alternator assly on the base frame/ plate. (d) Base Plate: made out of structural steel as per manufacturer (s) recommended design/ specifications. (e) Silencer : Absorption type non resistance, residential and exhaust pipe cover with aluminium cladding with suitable size of aluminium sheet as specified by manufecturer about 2 meters out side the ecoustic enclosure.
(f) 02 Nos 12 volts x 165 AH maint free batteries complete with suitable size copper lead. (g) Electronic control panels for all parameter ie. Digital AVR, Digital electronic governing and smart starting, Genset monitering, Engine metering, AC alternator metering, AC bus/ Utility monitering, Engine protection, AC alternator protection, AC utility protection, fault monitering, Data logging, configurable input/ outputs, Modbus interface( RS485RTU) Amp sentryprotection,digital frequency synchronization & voltage matching., Isochronous load share and Digital power transfer control.(Power command control 3.3) (h) Exhaust System & Insulation: (i) Supply & Installation of Class B MS pipe 8" ( 200 mm ) dia used before Y joint on the DG set including aluminium cladding & bend. (ii) Supply & Installation of Class B MS pipe 16" ( 400 mm ) dia used after Y joint upto 30 Meter hight from the ground level incl aluminium cladding & bend. (j) Exhaust System support: Provn of 30 meter exhaust support structure MS angle with 2 coats of syenthtic enemal paint over a coal of red oxide primer and necessary foundation as reccommended by manufecturer and as per CPCB norms. (k) Lightening arrestor: LED avaiation light connected through 3 core 2.5 sqmm copper cable laid in PVC conduit alongwith MS supoort. (l) Fuel system: (i) fuel pipe of size 1" MS class C with bend and flanged ,clamps end fitting along with one coat of primer and two coat of enemal paint for connection from fuel tank to Engine. (ii) Fuel tank of 8 hrs capacity but not less than 990 ltrs, made out of 14SWG CRCA MS sheet, duly powder coated and provided with guage and fuel float switch.
(m) Catalogues: Operation and Maint manual, spare parts list, overhauling manual 03 sets (n) AMF Logic panel: Suitable sizes of copper cable for connection of logic panel with main LT panel will be provided by the contractor as per manufacturer instructions. (i) Key switch/ auto start Generator Set controller . (ii) Multifunction meter displaying the below parameters: voltage, current, frequency, water temperature, oil pressure, KVA, KW, MCCB. (iii) Contactor with HRC fuses of suitable capacity MCCB of suitable rating, current transformers, AMF logic, battery charger, aluminium busbar of suitable capacity, indicating lamps. (o) Power copper cables for internal connection: Sizes of copper conductor power cable for internal connection from DG set to logic panel will be provided by contractor as per manufacturer instruction. (q) DG set foundation shall be provided by the contractor as per manufacurer specificaiton.
SITC of busbar trunking 4 Pole Sandwich type (3L+N+PE) of Aluminium busbar 2500A 50KA for 1 Sec (Cu + Tin / silver plated at joints) including with all accesories like Elbow,Flange End & joint kit busbar trunking enclosure shall be made of 1.5mm thick GI/aluminium, Integral Earth in aluminium in 1.5mm,12kV impulse withstand & IP 55 without plug in point with IP-55 with multilayer PET Class-F Insulation temprature rise of 55 deg centigrate over an ambient of 40 deg C as per IEC 61439 - 6(2012) including necessary angle iron structrual 3.5 meter over head suppots duly painted with primer & aluminium paint complete all as specified & directed. ( Note :- Test certificate of bus bar trunking from OEM will be provided.)
Supply & fixing adaptor box of capacity upto 2500A with copper braided flexible jumper for connaction of aluminium bus bar complete all as specified and directed.
Supply & fixing canopy which shall be 1.6mm thick with Painted with colour RAL-7035, in CRCA Sheet maximum length 1 Meter to 1.5 mtr, with following louvers at side for Air circulation and heat dissipation purpose for aluminium busbar sandwich type /Air Insulated type of any rating where as required or complete all as specified and directed.
Material and labour fabricated structural steel sections and threaded bolt including nut, bolts washers, welding, bending drilling holes, grounting in wall/ceiling in any shape and sizes complete all as specified and directed.
M & L Earthing complete with copper earth plate 60×60cm ×3.15mm thick buried directly in ground(earth) pit not less than 2.25 meter deep below normal ground level) with top edge of earth plate not less than 1.5mtr below normal ground level connected to 20×3mm copper strip by means of bolts, nuts check nuts and washers of galvanized iron or steel all as shown in electrical plate No 3 of SSR Pt-I connected earthing test point/panel all as specified including PCC earth chamber using PCC(1:3:6) Type C-2 using, graded stone aggregate,50mm thick cast iron frame with CI cover, funne and wire in mesh excavation and earth work complete all as specified and directed. (For Tfr-28 sets, For DG Set- 16 Sets & 04 No for LT Panels & 01 Set for Lightening protection)
M& L for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required copper strip 50 x 6 mm size
All as per item No. 8 (here-in-before) but GI Strip of 25 x 4 mm size
Taking out old cable of existing size from ducts / trenches and cleaning of ducts complete all as specified and directed.
Relaying of serviceable part of LT cable of any size retreived from item ser No 10. (here-in-before) complete all as specified and directed.
Supply & laying XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, in trench/ in pole/ in duct of 3.5 core x 400 sqmm complete all as specified and directed.
Taking shutdown disconnecting of HT / LT cable of existing size from the transformer, lifting of old tansformer from existing plateform & shifted to place whereas directed complete all as specified and directed.
Supply, fabricate, installation, test and commissioning of LT control panel TTA, indoor type powder coated, weather proof,dust proof,vermin proof made out of 2.0 mm thick CRCA sheet front and back separate cabine openable door, suitable working space in bus bar chamber, cable box chamber with alley suitable for 3 phase 4 wire system,415 volts , 50 Hz, AC supply including main aluminium bus bar 6mm thick of rating 3200 amps with sleeve insulated & all bus bar riser of suitable capacities shall be extended upto cable box chamber fixed on fibre/polymide insulators for RYB & neutral to all out going cables, confirming to IEC-IEC 61439-1&2(TTA design) OEM switchgears manufacuturer comprising the follwings:- (A) Incomers: (a) 04 Nos incomer for 1600 KVA transformers with provn for busduct termination on top of the panels & each comprising of:- (i) 2500 Amps 4 pole , EDO ACB with microprocessor released 60 KA ( over load / short circuit & earth fault) with microswitch. (ii) break control switch. (iii) RYB phase indicating lamps (iv) ON/ OFF/ TRIP indicating lamps (v) MCB 2 A SP 'C' curve 10 KA (vi) Digital multifunction meter ( voltage, Ampere, frequency, KVAR & PF) (vii) CT 2500/5A, CL-1, 15 VA ( Tape wound)
(b) 02 Nos incomer for 1500 KVA DG set with provn for busduct termination on top of the panels & each comprising of :- (i) 2500 Amps 4 pole , EDO ACB with microprocessor released 60 KA ( over load / short circuit & earth fault) with microswitch. (ii) break control switch. (iii) RYB phase indicating lamps (iv) ON/ OFF/ TRIP indicating lamps (v) MCB 2 A SP 'C' curve 10 KA (vi) Digital multifunction meter ( voltage, Ampere, frequency, KVAR & PF) (c) 02 Nos Buscoupler & each comprising of :- (i) 2500 Amps 4 pole , EDO ACB with microprocessor released 60 KA ( over load / short circuit & earth fault) with microswitch. (ii) break control switch. (iii) ON/ OFF/ TRIP indicating lamps (iv) MCB 2 A SP 'C' curve 10 KA (B) Outgoings: (a) 02 Nos 1600A ACB feeder for AC plant 1 & 2 & each comprising of :- (i) 1600 Amps 4 pole , EDO ACB with microprocessor released 60 KA ( over load / short circuit & earth fault) with microswitch. (ii) break control switch. (iii) ON/ OFF/ TRIP indicating lamps (iv) MCB 2 A SP 'C' curve 10 KA
(b) 03 Nos 1250A LT feeder each comprising of :- (i) 1250 Amps 4 pole , EDO ACB with microprocessor released 60 KA ( over load / short circuit & earth fault) with microswitch. (ii) break control switch. (iii) ON/ OFF/ TRIP indicating lamps (iv) MCB 2 A SP 'C' curve 10 KA (c) 01 Nos 1000A ACB feeder for central kitchen transformers with provn of busduct termination on top of the panels & each comprising of :- (i) 1000 Amps 4 pole , EDO ACB with microprocessor released 60 KA ( over load / short circuit & earth fault) with microswitch. (ii) break control switch. (iii) ON/ OFF/ TRIP indicating lamps (iv) MCB 2 A SP 'C' curve 10 KA (d) 11 Nos 800A ACB feeder for PET scan, B-D,/ E-B, fire fighting pump, W/S pump, C block, B block , C block. Md accn1 & 2, pers line caferteria & spare (04 ACB's with provn for busduct termination on top of the panels and 07 Nos with cable termination) & each comprising of:- (i) 800 Amps 4 pole , EDO ACB with microprocessor released 60 KA ( over load / short circuit & earth fault) with microswitch. (ii) break control switch. (iii) ON/ OFF/ TRIP indicating lamps (iv) MCB 2 A SP 'C' curve 10 KA
(e) 04 Nos MCCB for capacitor bank & comprising of :- (i) 630 Amps 4 pole , with thermal magnetic release 36 KA (O/L, S/C) (ii) Rotary handle for MCCB (iii) Spreader link for MCCB (iv) Ammeter 630 Amps (iv) Voltmeter 0-500 Volts (v) Current Transformer 630/5A, Cl-1, 15VA (f) 07 Nos MCCB for Generator auxilary, Officers qtr, pump house & comprising of :- (i) 400 Amps 4 pole , with thermal magnetic release 36 KA (O/L, S/C) (ii) Rotary handle for MCCB (iii) Spreader link for MCCB (iv) Ammeter 630 Amps (iv) Voltmeter 0-500 Volts (v) Current Transformer 400/5A, Cl-1, 15VA (g) 04 Nos MCCB for boiler house 1&2 , commandant house,spare & comprising of :- (i) 200 Amps 4 pole , with thermal magnetic release 36 KA (O/L, S/C) (ii) Rotary handle for MCCB (iii) Spreader link for MCCB (iv) Ammeter 630 Amps (iv) Voltmeter 0-500 Volts (v) Current Transformer 200/5A, Cl-1, 15VA
(h) 05 Nos MCCB for battery charger, street light , E/P sapre & comprising of :- (i) 200 Amps 4 pole , with thermal magnetic release 36 KA (O/L, S/C) (ii) Rotary handle for MCCB (iii) Spreader link for MCCB (iv) Ammeter 630 Amps (iv) Voltmeter 0-500 Volts (v) Current Transformer 200/5A, Cl-1, 15VA (j) 05 Nos MCCB for incinerator & comprising of :- (i) 63 Amps 4 pole , with thermal magnetic release 25 KA (O/L, S/C) (ii) Rotary handle for MCCB (iii) Spreader link for MCCB (iv) Ammeter 630 Amps (iv) Voltmeter 0-500 Volts (v) Current Transformer 100/5A, Cl-1, 15VA (k) Panel enclosure made out of 14/16 SWG CRCA duly powder coated (l) 3200 Amps, aluminum TPN
Supply, fabricate, installation, test and commissioning of LT TTA control panel, indoor type powder coated, weather proof, dust proof,vermin proof made out of 2.0 mm thick CRCA sheet front and back separate cabine openable door, suitable working space in bus bar chamber, cable box chamber with alley suitable for 3 phase 4 wire system,415 volts , 50 Hz, AC supply including main aluminium bus bar of rating 3500 amps & all bus riser of suitable capacities shall be fibre/Polymide insulators for RYB & neutral to all out going cables confirming to IEC- 61439- 1&2 (TTA design) OEM switchgears manufacturer comprising the followings:- (A) Incomers: (a) 3 Nos. INCOMER FROM 1600 KVA TRANSFORMER WITH PROVN FOR BUSDUCT TERMINATION ON TOP OF THE PANELS & EACH COMPRISING OF:- (a) 3 Nos. INCOMER FROM 1600 KVA TRANSFORMER EACH COMPRISED OF (i) 2500A,4P,EDO,ACB with Microprocessor Released 60KA (O/L,S/C,E/F) with Microswitch (ii) Breaker Control Switch (iii) RYB Phase Indicating Lamps (1 SET) (iv) ON/OFF/TRIP Indicating Lamps (v) 2A,SP,MCB 'C' CURVE 10 KA (vi) Digital Multifunction Meter (V,A,F,KW,KVAR,PF) (vii) Current Transformer 2500/5A,CL-1,15VA (Tape Wound)- 01 Set
(b) 2 Nos. INCOMER FROM 1500 KVA DG SET WITH PROVN OF BUSDUCT TERMINATION ON TOP OF THE PANELS & EACH COMPRISING OF:- (i) 2500A,4P,EDO,ACB with Microprocessor Released 60KA (O/L,S/C,E/F) with Microswitch (ii) Breaker Control Switch (iii) RYB Phase Indicating Lamps (1 SET) (iv) ON/OFF/TRIP Indicating Lamps (v) 2A,SP,MCB 'C' CURVE 10 KA (vi) Digital Multifunction Meter (V,A,F,KW,KVAR,PF) (vii) Current Transformer 2500/5A,CL-1,15VA (Tape Wound)- 01 Set © 2 Nos BUSCOUPLER EACH COMPRISED OF (i) 2500A,4P,EDO,ACB with Microprocessor Released 60KA (O/L,S/C,E/F) with Microswitch (ii) Breaker Control Switch (iii) RYB Phase Indicating Lamps (1 SET) (iv) ON/OFF/TRIP Indicating Lamps OUTGOINGS (i) 1 No. 1000A, ACB FEEDER FOR ART (ii) 1000A,TP,EDO,ACB with Microprocessor Released 50KA (O/L,S/C,E/F) with Microswitch (iii)Breaker Control Switch
NOTE FOR ITEM SER No 15 & 16:- The LT control panel shall be OEM switch gears manufacturer design and shall have logo of OEM switchgears manufacturer on top of the panel. (b) OEM will stand warrenty of 05 years for complete design supply and inspection upto site service support. (c) Panel will be pre-tested at OEM site/factory. (d) All the ACB's Shall have current display with built in battary backup and 20 trips fault history (e) The following test must be carried out for LT panels and report shall be submitted to MES office:- (i) LT panel shall be confirming to latest IEC 61439- 1& 2 (TTA Design) (ii) Internal Arc tests 65 KA for 0.4 sec as per IEC61641. (iii) Mechanical impect test IK10 as per IEC. (iv) Form separation for 3b as per IEC degree of protection
Supply only Heat shrinkable LT 1.1 KV straight through joint suitable for aluminium cable of Size 400 Sqmm x 3.5 core complete all as specified and directed.
S&F bus bar chamber indoor type 800 Amps rated aluminium bus bar 4 Nos, suitable for one incoming and one outgoing of 400 Sqmm 3.5 core XLPE cable, and provn of 02 Nos earth connection to the chamber, with angle iron legs size 40 x 40 x 6 mm, standard PCC foundation & copping, cable connection with suitable cable glands etc all as specified and directed
All all as per item No 18 (here-in-before) but for 630 Amp.
Description of Work / Item(s)
Amount
Dismantlling of Unserviceable/old vintage nurse call system wireless/wired type including bed unit complete all as specified and directed.
Supply and fix in replacement and testing commissioning of wireless display and controlling unit with human voice address with build-in RFAF (radio frequency attention filter) with coade blue and data loggging facility having the following, specification complete all as directed :- (i) Capacity : Max 50 beds, 7 seg LED display max, 2 digit for one bed receiving 3 LED indicators ( Nurse Calling, House Keeping and Code Blue) (ii) Power reqirement : AC 230 V, 5Amps, 50 Hz (iii) Operating Temp : 0 to 50 degree ( 32 degree F - 122 dgreeF) (iv) Operating Humidity: 10%-90% without congealment (v) Operating Voltage : 05 volt DC-12 volt DC (vi) Operating current : 200mA, Standy<30mA, Full load<35mA (vii) Startup current : 600 mA (viii) Speaker : Full duplex (ix) Impedence : 8C + 15% (x) Max outout Power : 0.5 W (xi) Distribution Rate : 5% Max (xii) Max dB : 89 + 3dB (xiii) Frequency Range : 433 MHz (xiv) Power Cable 1.5 meter long 2/3 core up to 1 Sqmm Make - Shreya Elecronic, Courtony Thome, Cornell
Supply and fix in replacement and testing commissioning of wireless multiservice for three service call ( Nurse Calling, House Keeping and Code Blue) Bed unit and reset with wireless door indicator, with built-in RFAF, with code blue and data logging facility , operating temp 0 degree centigrade-50 degree centrigade( 32 degree F - 122 degree F) operating voltage humidity 10%-90% without congealment power requirement, operating voltage 12 Voltage battery opearing current -standby< 10 mA, working status < 10 mA packing contents wireless bed unit button with handset DC 12V battry screws and mounting plate including fixing accessories, complete all as specified and directed.
Supply and fix in replacement multi service handset with three service calling, Reset and door Indicator including 02 meter wire with L type jack conteness environment condition including all accessories complete all as specified and directed.
Description of Work / Item(s)
Amount
Taking shutdown, disconnection all existing electric connection of busbar and taking down existing busbar trunking including tap off box, end feed units, adopter unit and MCCB's etc. and shifting to MES store yard complete of following sizes all as directed by Engr-in-Charge
(a) 100 amps Capacity
(b) 200 amps capaacity
(c) 300 amps Capacity
(d) 600 amps capaacity
(e) 800 amps Capacity
Disconnecting and taking down exsiting false ceiling &connected items carefully incl exsiting LT cables off capacity, cable tray, and keeping in safe place wherever in site and re-use/ re-fixing of the same in existing position and making good after taking down old BBT off capacity & making suitable space for fixing of new sandwich type BBT off capacity complete all as specified and directed. Note : If any damages in items during taking down, the same will be provided by the contractor and No extra payment will made in this effect.
Supply, install, commissioning and testing busbar trunking 4 Pole Sandwich type, 3 Ph 4 Wire System ( 3P+N+E) of Aluminium busbar 630A 36KA (Cu + Tin plated at joints) including with all accesories like Elbow, Flange End & hanger anchor bolt with MS angle support ,busbar trunking enclosure shall be made of 1.5mm thick GI/aluminium, Integral Earth in GI in 1.5mm, 12KV impulse withstand & IP 55 with plug in point and IP 55 without plug in point with IP-65 with multilayer PET Class-F Insulation. temprature rise of 55 deg centigrate over an ambient of 40 deg C as per IEC 61439-6 (2012) . Make - Legrand(Zucchini)/ Schneider/ Siemens Note :- Test certificate of bus bar trunking from OEM will be provided.
All as per item No 3 herein-before but 800 Amps 36 KA.
Supply installation commissioning & testing of LT aluminium busbar trunking system of 630 amps, 36 KA, 50 HZ 3 phase, 4 wire 100% neutral air insulated type with and three outlet on same side in every three meter span type enclosure fabricated out by 0.8 mm (minimum size) hot galvanized sheet steel duly painted/powder coated factory fitted conductor spaced by suitable insulators complete with and including supporting structure spring hanger, wall bracket joint cover mono block for fast & reliable connection of live conductors plug outlet cover etc including anchor fastner (nut bolts etc) to fix busbar trunking properly complete all as specified and directed. Note : Spring hanger and end enclosure shall be measured and paid separatly.
Supply and fix Tap off box enclosure, metal body type with provision of interlock to prevent removal when outgoing is in ON position including MCCBs complete with internal electrical connection with suitable size of copper conductor of following
(a) 100/125 amps Capacity with 125 A 4P 25 KA MCCB
(b) 250 amps Capacity with 250 A 4P 25 KA MCCB
(c) 400 amps Capacity with 400 A 4P 36 KA
Supply & in replacment of adopter box of capacity upto 800 Amp, 40 KA with copper braided flexible jumper for connection of aluminium busbar 3 phase 4 wire sandwich type as specified in Items Ser No 03 & 04 above all as specified.
Supply and fix tap off box enclosure metal body type with provision of interlock to prevent removal when outgoing is in ON position and with provision of interlock to turned ON MCCB when the tap off unit cover is open including MCCBs complete with internal electrical connection with suitable size of copper conductor of following: capacities and suitable for fixing in item Ser No 05 all as directed by Engr-in-charge. Make - Legrand(Zucchini)/ Schneider/ Siemens
(a) 100/125 amps Capacity with 125 A 4P 25 KA MCCB.
Material and labour of end feed unit of capacity 630 amp with provisioning of 01 x 630 amps 4 pole 50 KA ICS=100% =ICU with thermal magnetic release including copper spreader (02 sets) of same capacity suitable for Aluminium BBT 630 Amps with earthing strips complete all as directed by Engr-in-charge.
Material and labour for replacement of PVC insulated unsheathed heavy duty industrial cable unarmoured copper condutor 35 sqmm single core all as directed by Engr-in-charge.Make: Havells/ Polycab
S & F of canopy which shall be 1.6mm thick with Painted RAL-7035, in CRCA Sheet maximum length 1 Meter to 1.5mtr, with following louvers at side for Air circulation and heat dissipation purpose for aluminium busbar sandwich type /Air Insulated type of any rating where as required or as directed,
Material and labour of spring hanger suitable for holding vertical busbar truncking 630 A to 800 amps complete all as directed by Engr-in-charge
M&L for cross arms bracings supports, clamps angle iron flats and back plates fabricated from MS structural steel sections including nuts, bolts and washers of suitable sizes including welding bending (cold or hot) drilling holes for bolts in any shape or size as indicated or directed and inclusive of two coats of aluminium paint over one coat of red oxide primer, complete all as specified.
Supply & Fixing of End enclosue unit for vertical busbar trunking. Make - Legrand(Zucchini) Part No 50403101 / Schneider/ Siemens Note: Materials pertaining busbar truncking provided by the contractor should be in same make / company.
Description of Work / Item(s)
Amount
Taking Down of Solar Penal From the old position and refixing in same position including All electctric connection and iron angle welding, cutting, drilling and all necessary coneection with packing complete
Taking up or down steel tubing of bore size 15 mm and connections all fittings (such as gate valve,elbow,tee,union,nipple),including cleaning for refixing or removal to store all as directed
Taking up or down steel tubing of bore size 20 mm and connections all fittings (such as gate valve,elbow,tee,union,nipple),including cleaning for refixing or removal to store all as directed
Taking up or down steel tubing of bore size 25/32 mm and connections all fittings (such as gate valve,elbow,tee,union,nipple),including cleaning for refixing or removal to store all as directed
Taking up or down steel tubing of bore size 40/50 mm and connections all fittings (such as gate valve,elbow,tee,union,nipple),including cleaning for refixing or removal to store all as directed
Taking up or down steel tubing of bore size 80 mm and connections all fittings (such as Sluice valve, gate valve,elbow,tee,union,nipple),including cleaning for refixing or removal to store all as directed
Taking up or down steel tubing of bore size 100 mm and connections all fittings (such as Sluice valve, gate valve,elbow,tee,union,nipple),including cleaning for refixing or removal to store all as directed
Refixing old steel tubing and connections of bore size 15 mm in connections all fittings (such as gate valve,elbow,tee,union,nipple) all as directed new or old position(walls,celling,floors etc.)
Refixing old steel tubing and connections of bore size 20 mm in connections all fittings (such as, gate valve,elbow,tee,union,nipple) all as directed new or old position(walls,celling,floors etc.)
Refixing old steel tubing and connections of bore size 25/32 mm in connections all fittings (such as gate valve,elbow,tee,union,nipple) all as directed new or old position(walls,celling,floors etc.)
Refixing old steel tubing and connections of bore size 40/50 mm in connections all fittings (such as Sluice valve, gate valve, elbow, tee, union, nipple) all as directed new or old position(walls,celling,floors etc.)
Refixing old steel tubing and connections of bore size 80 mm in connections all fittings (such as Sluice valve, gate valve,elbow,tee,union,nipple) all as directed new or old position(walls,celling,floors etc.)
Refixing old steel tubing and connections of bore size 100 mm in connections all fittings (such as Sluice valve, gate valve, elbow,tee, union, nipple) all as directed new or old position(walls,celling,floors etc.)
M&L for insulation for 25mm bore pipe or plumbing all round with 25mm thick bonded mineral wool preformed 'SNAPON' pipes sections of density 144 kg/cum conforming to IS 9842 with aluminium foil of thickness 26 SWG and applying suitable adhesive compound over and including chicken mesh wire netting 25 gauge, 20 mm mesh complete with and incl taking down of old insulation, preparation of pipe surface by scratching / removing rust, dust and old paints etc with wire brush, emery paper, grinder etc and making surfaces smooth for achieving better grip between surface and primer, applying one coat of red oxide primer, complete all as directed.
All as per srl item No 14 here-in-before but of size 32 mm bore.
All as per srl item No 14 here-in-before but of size 20 mm bore.
All as per srl item No 14 here-in-before but of size 15 mm bore.
All as per srl item No 14 here-in-before but of size 40 mm bore.
Taking Down of Solar Stainless steel tank of capacity 5000 Ltr From the old position and refixing in same vertical position including All electctric connection and iron angle support with welding,cutting,drilling and all necessary coneection with packing complete all as directed
SHIVALAYA CONSTRUCTION CO. PVT LTD
B D Raizada Projects Pvt Ltd
NITYA NAND AND SONS CONTRACTORS PVT LTD
Som Projects Pvt Ltd
SOOD ASSOCIATES PVT LTD
NARSINGH DEVELOPERS LLP
B D Raizada Projects Pvt Ltd
SOOD ASSOCIATES PVT LTD
NARSINGH DEVELOPERS LLP
City Promoter and Buildwell Pvt. Ltd.
SHIVALAYA CONSTRUCTION CO. PVT LTD
NITYA NAND AND SONS CONTRACTORS PVT LTD
B D Raizada Projects Pvt Ltd
Som Projects Pvt Ltd
SHIVALAYA CONSTRUCTION CO. PVT LTD
SOOD ASSOCIATES PVT LTD
NITYA NAND AND SONS CONTRACTORS PVT LTD
NARSINGH DEVELOPERS LLP
B D Raizada Projects Pvt Ltd
SHIVALAYA CONSTRUCTION CO. PVT LTD
SOOD ASSOCIATES PVT LTD
NITYA NAND AND SONS CONTRACTORS PVT LTD
NARSINGH DEVELOPERS LLP
Som Projects Pvt Ltd
B D Raizada Projects Pvt Ltd
City Promoter and Buildwell Pvt. Ltd.
SOOD ASSOCIATES PVT LTD
NARSINGH DEVELOPERS LLP
SHIVALAYA CONSTRUCTION CO. PVT LTD
NITYA NAND AND SONS CONTRACTORS PVT LTD
SHIVALAYA CONSTRUCTION CO. PVT LTD
NITYA NAND AND SONS CONTRACTORS PVT LTD
Som Projects Pvt Ltd
B D Raizada Projects Pvt Ltd
SOOD ASSOCIATES PVT LTD
NARSINGH DEVELOPERS LLP
Bidder Name
B D Raizada Projects Pvt Ltd
SOOD ASSOCIATES PVT LTD
City Promoter and Buildwell Pvt. Ltd.
NITYA NAND AND SONS CONTRACTORS PVT LTD
Som Projects Pvt Ltd
SHIVALAYA CONSTRUCTION CO. PVT LTD
NARSINGH DEVELOPERS LLP
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid