| 1 | L1₹1.5 CrAccepted-Finance | ₹1.5 Cr | L1 | Accepted-Finance Found 1st Lowest |
| 2 | L2₹1.5 Cr+₹17,838.15 (0.12%)Accepted-Finance 560 SADAR BAZAR JHANSI UTTAR PRADESH 284001 | JHANSI | UTTAR PRADESH | 284001 | ₹1.5 Cr+₹17,838.15 (0.12%) | L2 | Accepted-Finance Found 2nd Lowest |
| 3 | L3₹1.5 Cr+₹5.0 L (3.42%)Accepted-Finance | ₹1.5 Cr+₹5.0 L (3.42%) | L3 | Accepted-Finance Found 3rd Lowest |
| 4 | L4₹1.6 Cr+₹13.9 L (9.55%)Accepted-Finance 00 OPP RASHMI HOSPITAL RAYA ROAD LAXMI NAGAR MATHURA UTTAR PRADESH 281204 | MATHURA | UTTAR PRADESH | 281204 | ₹1.6 Cr+₹13.9 L (9.55%) | L4 | Accepted-Finance Found 4th Lowest |
| 5 | L5₹1.7 Cr+₹19.3 L (13.2%)Accepted-Finance | ₹1.7 Cr+₹19.3 L (13.2%) | L5 | Accepted-Finance Found 5th Lowest |
Tender Value
₹1.8 Cr
EMD Value
₹4.2 L
Closing Date
11 Dec 2025, 5:00 pmClosed
Senior Manager (E) HQ
A-1/4 Lakhanpur, Kanpur
Providing decorative pole at entrance and street light dark spot location at G.C. and Bijauli Jhansi.
2025_SIDC_1092668_1
ED_I_350_16102025
Open Tender
Electrical Works
Percentage
120 days
Jhansi
Please refer Tender documents.
3 documents required · 3 mandatory
₹5,434
UPSIDA
₹4.2 L
11 Feb 2026
21 Nov 2025
12 Dec 2025
21 Nov 2025
11 Dec 2025
21 Nov 2025
Supply & fixing steel tubular pole 9 Metre long designated 410 SP-29 in 1:3:6 cement concrete foundation including excavation back filling etc. complete in all respect. UPPWD Sch no 610
Supply & erection of stay set at 3.5 Metres away from the pole complete with galvanised 19 mm dia x1.80 Metre long stay rod, 30 cm x 30 x 6.3 mm anchor plate, thimble stay clamps, stay insulator,19 mm 600 mm double screw tightener, 7/3.5 mm G.I. stay wire etc. in 1:3:6 cement concrete complete in all respect. UPPWD 631
Supply and fixing of LED Street light fitting having die cast aluminium body and diffuser with driver set suitable for 120 watt confirming to IP 66 protection complete in all respects (With 5 Year Gaurantee(3+2) Three year all type (including Damage & Theft) Repair & Maintenance & Extra Two Year Gaurantee). Catt. AA as per UPPWD Sch. No.1424 (Bajaj /Philips/Crompton/Wipro Make)
Supply & Fixing of Decorative Pole made of mild Steel with a total height of 7 mtr above ground level with Single arm bracket for S.L and predefined laser cut pattern in the top portion of the bracket of the pole. Pole bottom base section shall be 250x250x1500mm, 4mm thickness column with two side predesigned laser cut to illuminate the surrounding in 20W with noticeable mode, between section pole of 90x4500x3.2mm, then 76x1000x3mm top bracket with illuminated laser cut pattern design one side of 1000mm to bold the S.L. as per shared drawing. The base plate of pole shall be of size 400x400x12mm. Provision for inside termination box with for away connector & Ions 6 Amps MCB for local isolation. The pole is primarily coated with primer, secondary epoxy resin and top coated with UV stabilized powder coat and cured. The decorative pole is suitable for outdoor lighting application. Pole light is complete in all aspects with all accessories with foundation bolts.Technical specification to be approved by engineer in charge
Supply and fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 175 to 200 Watt. Confirming to IP 66 Protection complete in all respects UPPWD 1425(A) CAT AA (Bajaj /Philips/Crompton/Wipro Make)
Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over on DWC/HDPE Pipe. laid below ground level of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. as per UPPWD 501(k) 35 3.5 core Make Havells/KEI/Grandley/Gloster/Polycab
S/F of M.S. Earthing rod (2500x20mm) in vertically ground level and connecting the pole with help of 6 SWG GI wire including cost of all material men & TNP.
Supply & Fixing of 32 MM Dia 1.20 Mtr long G.I Pipe Bracket For Fixing of LED lights complete in all respects with clamp etc.
Supply & fixing of D clamp of size 50x6 mm flat iron on ST poles with nuts and washers etc. complete in all respect as per UPPWD Sch. No. 623
Supply & fixing of 100 x 110 mm shackle insulator 100 x 80 mm pin insulator including GI volt spindle, nuts etc. as pre UPPWD Sch. No. 621
Supply, sagging, jointing and binding of insulated ACSR Weasel conductor including cost of aluminium tape binding and jointing sleaves etc. complete in all respect.
Supply and laying of 16 sqmm 4 core aluminium conductor PVC insulated armoured served sheated cable 110 volt grade laid in DWC pipe complete in all respects including all T&P men materials required for propercompletion of work as per UPPWD Sch no 501(i) & 507 (Polycab/KEI/Havells/Grandley/Gloster make)
Supply & fixing of 16mtr high mast shaft of approved make with rising system hot dip galvanized inside & outside dip, heavy pole sheet thickness 3mm top dia minimum 150 mm bottom dia minimum 360mm base plate thickness 32mm thick suitable for wind velocity as per IS 875 part 3 & having no circumferntial weld with accesories for high mast such as head suitable for 6 to 12 lumaniries and its control gear boxes 1.5HP power tool 3 point suspension system with steel wire rope 6mm dia double drum winch including making suitable foundation as per manufacture drawing/ site requirement along with foundation bolts nuts washer anchor plate etc complete in all respect as per UPPWD Sch no 652 (Bajaj /Philips/Crompton/Wipro Make)
Supply and fixing of factory wired integral LED Flood light lumanaries with die cast aluminium body and diffuser with driver set suitable for 200 watt confirming to IP 66 protection complete in all respects (With 5 Year Gaurantee(3+2) Three year all type (including Damage & Theft) Repair & Maintenance & Extra Two Year Gaurantee). Catt. AA as per UPPWD Sch. No.1455 (Bajaj /Philips/Crompton/Wipro Make)
supply & laying of 25 mm x 3mm G.I Strip from earth electrode directly in ground as required aspects as per uppwd Scho no 716
S/F of 40mm dia x 4.5 mtr long GI pipe vertically for earthing having 12 mm earthing 12mm di holes spaced 75mm apart drilled upto 2 mtr from the bottom complete with earthing lead no 6 to 8 SWG wire GI wire in GI pipe upto appron upto switch board 30 CM square box with hinged cover masonary enclosure funnel of top , alternate layers of charcoal and at least 150 mm thick alround as per UPPWD Sch no 701
supply and fixing of 100mm dia GI pipes class 'B' for protection and climbing up the cable from ground to over head line including all accessories, material, labours, and T&P required for proper completion of work as per specification as per UPSIDC Sch no ER(25)
S/F of 11KV three phase D.O fuse set complete with suitable clamps nuts & bolt fuse wire etc .
Supply & laying of 63mm dia (OD-63mm & ID-51mm nominal) DWC HDPE pipe ISI marked along with all accessories like socket, bend, couple etc. confirming to IS 14930 Part II complete with fitting and cutting jointing etc direct in ground ( 75 cm below ground below) including excation and refillling the trench but excluding sand cushoning and protective covering etc. complete
Supply & laying of 63mm dia (OD-63mm & ID-51mm nominal) DWC HDPE pipe ISI marked along with all accessories like socket, bend, couple etc. confirming to IS 14930 Part II complete with fitting and cutting jointing etc direct in ground ( 75 cm below ground below) through horizontal boring (trenchless) by making a pit at regular internal and refilling the pit after work as before on road crossing including cost of material men and T&P
Supply & laying 16 sq mm 2 core Al. conductor PVC insulated armoured, served, sheated cable 1100 V grade in existing HDPE pipe laid below ground level. The armouring of the cable shall be properly connected with earth conductor by clamp etc. as per PWD Sch. 501(c) & 507 (Polycab /KEI/ Havells/ Grandley/Gloster Make)
Supply & laying 25 sq mm 3.5 core Al. conductor PVC insulated armoured, served, sheated cable 1100 V garade in existing HDPE pipe laid below ground level. The armouring of the cable shall be properly connected with earth conductor by clamp etc. as per PWD Sch. 501(j) & 507 (Polycab /KEI/ Havells/ Grandley/Gloster Make)
S/F of brass nickel Plated compression gland for PVC insulated and armoured served sheated ,underground cable including rubber ring etc. comlete in all respects.the armouring of the cable shall be properly connected with the earth as per direction of Engineer - incharge as per UPPWD sch. no. 503 (c) 16 sq. mm 2 core
S/F of brass nickel Plated compression gland for PVC insulated and armoured served sheated ,underground cable including rubber ring etc. comlete in all respects.the armouring of the cable shall be properly connected with the earth as per direction of Engineer-incharge as per UPPWD sch. no. 503 (k) 25 sq. mm 3.5 core
S/F of palm or pin type copper tin plated cable socket (lug) to the cable leads insulating with tap and making connection etc. complete in all respect as per direction of the Engineer- incharge as per UPPWD sch. No. 504 (d) 16 sq. mm
Supply & fixing 40A TPN automatic street light panel cubical panel painted with anti corrosive alkali acid proof paint consisting of time switch TSO 100 series with contractors, HRC Fuses, isolating switch metering instrument & instrument box with CTs etc
S/F of following capacity of automatic street light cubical cantrol panel painted with anti corrosive alkali and acid proof paint consisting of timer switch TSO 100 series with cintractors HRC fuses, isolating switch metering instuments box with CTS etc. as per UPPWD Sch. No. 807(e-ii) (25 Amp. TPN)
Strengthening of ST/Octogonal pole/High Mast/Panel, foundation by providing new concreting including broken of weak foundation,excavation below upto Ground level,Surface finishing and painting with white cement and dark yellow colour cost of all material men and T&P complete in all respect rates as per sanctioned (each in 1.5 year)
Painting of ST pole and all mountings on it with two coats of aluminium paints with an under coat of red oxide paint upto10 M. support above the ground level as per direction of Engineer in-charge of work/site including T&P , men & material required for proper completion of work and all HT poles UPSIDC Sch. No.24.20.(A) Make Burger/Nerolac/Asian
Painting letters (Pole no.) 2.5 cm upto 8.0 cm size complete on street light pole/panel/other electrical properties under UPSIDA including cost of all material men and T&P complete in all respect.
Supply and burying of 600mm x 600mm x 6mm G.I. plate vertically for earthing with its top at least 3 metres below ground level complete with 20mm dia G.I. pipe and funnel for watering and one earthing lead of one no. 8 to 10 SWG GI wire in 15mm dia G.I. pipe up to switch board (from appron to switch board the cost of G.I. pipe and G.I. wire will be extra) 30cm square C.I. frame with hinged cover masonry housing alternate layers of charcoal/coke and salt at least 150mm thick alround etc. as per directions of Engineer-in-charge complete in all respects as per drawing (This will apply for earthing of poles also).
Supply&Fixxing of of UPSIDA LOGO Plate (Retro-reflective) on High Mast including cost of clamp nut & bolts all material men and T&P complete in all respect.
Supply & laying 50 dia GI pipe trench less through manual boggi including 90 cm deep & refilling etc Ann-2
Tree Branches Triming for removing dark spots including cost of all material men and T&P complete in all respect.
Supply & errection of double pole structure with hardware & fittings on 410 SP-56 11 mtr long complete with 1/6th of over all length of pole in cement concrete with one feet square/ one feet dia cement concrete plinth around the pole above ground level. the foundation of underground will be of cement concrete in the ratio of 1:2:4. the stone ballast/ brick- ballast used will be 1.25cm (1/2 x 1) size with the stone pad 30x30x7.5cm at the base including all T&P men & material for proper completion of work as per direction of engineer in charge
Supply & fixing of 11KV pin insulator on channel arm fixed on ST/DP including cost of nut/bolt/washer T &P men & material for proper completion of work as per direction of engineer in charge.
supply & errection of stay set HT line for ST pole with GI anchor plate( 152x152x6mm) stay rod(16mm dia x 1.85 mtr long) GI stay below (16mm dia, thriple , double stay , tightner, stay insulator, clamps & stay wire including grouting in 1:4:8 ratio of cement concrete using course sand, over brunt brick ballast including all T & P men & material for proper completion of work
supply & fixing of anticlimbing device fabricated from GI flat of 25mm x 6mm size in sape of ring of the pole size having GI flat pointed fins of the length 225mm in 8 nos and also barbed wire in 200mm length above the said ring including material for proper completion of work as per direction of enginner in charge
supply and fixing of MS top channel 125x65x2240 mm including cost of holding clamps ans materials for proper completion of work as per direction in charge
supply and fixing of MS top channel 100x50x2000 mm including cost of holding clamps ans materials for proper completion of work as per direction in charge
supply & fixing of 11kv TPMO with complete with insulator & other accessories (Relco/azad/rama other standard make approved by UPPCL) proper completion of work as per direction in charge.
supply and fixing of of bolt channel/misc channel/other item as per si
supply & fixing of clamp suitable securing the above channel completes as per SIDC Sch no 3(4)
supply and installation, testing & commisioning of outdoor type aluminium wound oil cooled transformer rating 63 KVA 11/0.4 KV on double pole including cost of base channel & holding clamps approved by uppcl proper completion of work as direction of engineer in charge
supply & laying of 70 sq mm 3 core Al conductor XLPE insulated PVC bedded galvanised flat steel strip armoured, served sheated cable 1100v grade in existing HDPE pipe laid below ground level . The armouring of the cable shall be properly connected with earth conductor by clamp as per PWD sch no 506(d) & 507 (Polycab/KEI/Havells/Grandley/Gloster make)
Painting of ST pole high mast foundation excavation below upto ground level surface finishing and painting with white cement and dark yellow colour paint with double coat including cost pf all material men and T&P complete in all respect
te requirement including all T&P men & material for proper completion of work as per direction in charge .
Supply & laying of 90mm dia DWC HDPE pipe ISI marked along with all accessories like socket, bend, couple etc. confirming to IS 14930 Part II complete with fitting and cutting jointing etc direct in ground ( 75 cm below ground below) including excation and refillling the trench but excluding sand cushoning and protective covering etc. complete.
Supply & errection of factory fabricated and wired metal clad dust and vermin proof floor mounting panel TPN fuse switches with fuses and instrument chamber etc. as per UPPWD sch no 801 (b) (Incoming 100 amp 32 amp TPN -03)
S/F of outdoor/indoor type 11KV jointing kit heat shrinkable type for 11kv cable including cost of all material, labour T&P etc proper completion of work.
Fabrication,Supply & Fixxing of work information board in M.S frame made by 50 mm dia sqaure pipe of stainless steel grade SS-304 &16 mm thick base plate with back supporting of bracing by MS flat of 25x6 mm and 2.85 Mtr. Long supporting leg made from 65mm pipe SS-304 grade with proper grouting arrangement. The board should be Retro reflective type in green colour with white letters as required and shall be fixed at a height of 1.2 Mtr. from ground by providing 0.45x0.45x0.60 Mtr. cement concrete stone pad .
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.09 MB
FEEFORMAT.xls
Tender Documents • 0.03 MB
etenderdocuments.pdf
Tender Documents • 0.44 MB
BOQ_2007604.xls
BOQ • 0.39 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .