Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance 0 BUDKIYA DEVATRA JODHPUR RAJASTHAN 342606 | JODHPUR | RAJASTHAN | 342606 | Admitted-Finance |
Tender Value
₹8.8 L
EMD Value
₹9,000
Closing Date
20 May 2024, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Superintending Engineer, EDC, Hapur
Superintending Engineer, EDC, Hapur
For increasing capacity of Transformers and additional DP in area of EDD-II Hapur in business PLan 2024-25
2024_PVVNL_923986_2
145(W)/EDCH/2023-24
Open Tender
Electrical Works
Lump-sum
Hapur
enclosed
3 documents required · 3 mandatory
₹1,180
SE, EDC, Hapur
₹9,000
27 May 2024
9 May 2024
20 May 2024
9 May 2024
20 May 2024
9 May 2024
Amount
Increasing Capacity of 100 to 250KVA at various places as per sanctioned estimate, in area of EDD-II Hapur. (Third party inspection of the quality of all works will be conducted by the department).
Carriage of all petty material of estimate from JE Store/CTR/ESC, Hapur to site of work, including loading & unloading at both ends, as per direction of site incharge.
Safely dismantling of old 100KVA Transformer from Double Pole after open the connection, as per direction of site incharge.
Carriage of New 250KVA transformer from JE Store/CTR/ESC, Hapur to site of work, including loading & unloading safely at both ends, as per direction of site incharge.
Construction of T/F plinth suitable for 250KVA T/F (size of 2 x 2 x 1.5 mt.) as per drawing, cc work in foundation in ratio 1:4:8 (Cement, Sand & Brick ballast). Ist class brick work in side walls cc ratio of 1:4 (cement & fine sand). 12mm thick plaster in ratio 1:4 (cement & fine sand). The RCC work on top of plinth in ratio 1:2:4 after duly filling of brick ballast inside the plinth & ramming the same, including cost of all material & labour and as per direction of site incharge.
Safely installing the New 250KVA transformer with the help of crane/manual labour at LT Sub-Station Double Pole/Plinth, as per direction of site incharge.
Laying of LT Aluminum XLPE Cable 1x240Sqmm., by providing & fixing of required good quality lugs and completion of work properly as per RESPO/Norms, and as per direction of site incharge.
Connecting of the Jumper of LT & HT side and line energisation work properly, including fixing all required accessories at Double Pole/Plinth, as per direction of site incharge.
Construction of safety fencing (MS) for Transformer 11/0.4 KV Sub Station, With supply of material required for MS fencing (50X50X3 MM) M.S. wire mesh construction utilizing vertical post duly grouted/fitted in ground/on floor. Horizontal angle/T-iron to be fitted on vertical posts. Pickets (if required) fitted to rail and gate to facilitate entry and exit. The vertical Posts/Horizontal post shall be made of M.S. angle 75x75x6mm. Such post shall be kept preferably at distance of 800-1000 MM. and shall be grounded with CC ratio 1:4:8. The length of vertical post shall be sufficient to take care of fencing as requirement at site, and as per direction of site incharge.
Providing and installation of maintenance free multifaceted proactive and corrosion free chemical earthing electrod size 80mm x 3000mm complete with 50KG backfill compound with all required accessories for Body/neutral earthing of Transformers, including cost of M.S. earth strip for connection the earth strip will be welded to the earthing and neutral support, as per RESPO/Norms and as per direction of site incharge.
Carriage of old 100KVA transformer from site of work to JE Store/CTR/ESC, Hapur, with loading & unloading safely at both ends., as per direction of site incharge.
Construction of New 63/100/ 250KVA 11KV Sub-Station double pole in area of EDD-II Hapur, as per sanctioned estimate. (Third party inspection of the quality of all works will be conducted by the department.)
Carriage of line material (all petty material as per estimate) from Electricity Store Center, Hapur to site of work with loading and unloading at both ends on Kachha Packka road, as per direction of site incharge.
Carriage of all cable/conductor of estimate from JE Store/CTR/ESC, Hapur to site of work, including loading & unloading at both ends, as per direction of site incharge.
Carriage of ST Pole 11 mtrs. Long from Electricity store center, Hapur/J.E. Store to site of work with loading and unloading at both ends on Kachha Packka road, as per direction of site incharge.
Carriage of New 63KVA transformer from JE Store/CTR/ESC, Hapur to site of work, including loading of the same, as per direction of site incharge.
Carriage of New 100KVA transformer from JE Store/CTR/ESC, Hapur to site of work, including loading of the same, as per direction of site incharge.
Carriage of New 250KVA transformer from JE Store/CTR/ESC, Hapur to site of work, including loading of the same, as per direction of site incharge.
Erection of double pole structure with all accessories on ST Pole 11 mtr. long, fabrication and fixing of M.S. Top & Dropper Channel, M.S. T/F Angle, E-Bracket, 11 KV Pin insulator with Pin, Disc Insulator with Disc fitting etc., as per RESPO Drawing/Norms by providing all clamps made of M.S. Flat of size 50x6 mm with proper size nuts and bolts, and jumpering etc work, and as per direction of site incharge.
Errection of Chair type Structure on ST Pole/Rail/R.S. joists after digging of pits and fabrication of branching, top channel and structure for placing of 11.4 KV T/F., and placing and mounting of T/F on chair type Structure by providing all fixing materials, Nuts and Bolts Clamps and labour etc., and as per direction of site incharge.
Construction of T/F plinth suitable for 250KVA T/F (size of 2 x 2 x 1.5 mt.) as per drawing, cc work in foundation in ratio 1:4:8 (Cement, Sand & Brick ballast). Ist class brick work in side walls cc ratio of 1:4 (cement & fine sand). 12mm thick plaster in ratio 1:4 (cement & fine sand). The RCC work on top of plinth in ratio 1:2:4 after duly filling of brick ballast inside the plinth & ramming the same, including cost of all material & labour and as per direction of site incharge.
Construction of safety fencing (MS) for Transformer 11/0.4 KV Sub Station, With supply of material required for MS fencing (50X50X3 MM) M.S. wire mesh construction utilizing vertical post duly grouted/fitted in ground/on floor. Horizontal angle/T-iron to be fitted on vertical posts. Pickets (if required) fitted to rail and gate to facilitate entry and exit. The vertical Posts/Horizontal post shall be made of M.S. angle 75x75x6mm. Such post shall be kept preferably at distance of 800-1000 MM. and shall be grounded with CC ratio 1:4:8. The length of vertical post shall be sufficient to take care of fencing as requirement at site, and as per direction of site incharge.
Providing and installation of maintenance free multifaceted proactive and corrosion free chemical earthing electrod size 80mm x 3000mm complete with 50KG backfill compound with all required accessories for Body/neutral earthing of Transformers, including cost of M.S. earth strip for connection the earth strip will be welded to the earthing and neutral support, as per RESPO/Norms and as per direction of site incharge.
Safely installing the New 250KVA transformer with the help of crane/manual labour at LT Sub-Station Double Pole/Plinth, as per direction of site incharge.
Laying of LT Aluminum XLPE Cable 1x240Sqmm., by providing & fixing of required good quality lugs and completion of work properly as per RESPO/Norms, and as per direction of site incharge.
Connecting of the Jumper of LT & HT side and line energisation work properly, including fixing all required accessories at Double Pole/Plinth, as per direction of site incharge.
Installation of 63/100KVA T/F on double pole and line energisation work properly, as per RESPO Norms, and as per direction of site incharge.
Laying , Stringing and final sagging of ACSR weasel Conductor, as per RESPO/Drawing Norms and as per direction of site incharge.
Grouting & fixing of stay rods (20x1800)mm including all work of excavation, cement concrete in size (0.60x0.60x0.30)m in ratio 1:4:8 cement, sand, 40mm brick ballast as per drg. Including back filling, proper ramming etc and fixing tightening & nozzling of stay wire with stay rod with the poles of required tension as per drawing as per RESPO Drawing/Norms by providing all grouting material and stay clamp made of M.S. Flat of size 50x6mm with proper size bolts & nuts & loops., and as per direction of site incharge.
Earthing of supports with MS earth Rod of (20x2500)mm long including excavation of pit and driving M.S. Rod 3.0 M apart from support and 0.5m below the ground level and connection below the earth electrodes with the help of G.I. wire & earthing lugs as per RESPO Drawing/Norms by providing proper size nuts & bolts., and as per direction of site incharge.
Grouting of ST/PCC supports in CC 1:4:8 (Cement, sand & 40mm brick ballast) Grouting will be done in the block of size (450x450)mm x1/6th of full length of the support, up to ground level, 300mm plinth above the ground level with CC 1:3:6 (Cement, core sand and Stone grit) with mufting as per drawing, work includes back filling & proper ramming by providing all required grouting materials., and as per direction of site incharge.
Jumpering and line energisation work properly as per RESPO/Norms.
DUSHYANT ENTERPRISES
OM CONSTRUCTION COMPANY
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .