Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.1 LAccepted-AOC OFFICE NO 101 MALAN PLAZA NEXT TO ESSAR PETROL PUMP NEAR GODAMBLE CORNER RAHATNI PIMPRI DP ROAD RAHATANI PUNE 411 017 | PUNE | PUNE | MAHARASHTRA | 411017 | L1 | Accepted-AOC LOWEST BID | |
| 2 | L2₹11.9 L+₹4.7 L (64.9%)Rejected-Finance FLAT NO 203 SEC 14 PLOT NO 142 SHIVSRUTI PARK APARTMENT E WING 1ST FLOOR MOSHI PRADHIKARAN TAL HAVELI DIST PUNE 412 105 | PUNE | MAHARASHTRA | 412105 | L2 | Rejected-Finance NOT A LOWEST BID | |
| 3 | Rejected-Technical | - | Rejected-Technical Not meeting enlistment creteria |
Tender Value
₹12 L
EMD Value
₹24,000
Closing Date
1 Dec 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE MH AND RH KIRKEE
GE MH AND RH KIRKEE RANGE HILLS ROAD KIRKEE PUNE 411003
REPAIR MAINTENANCE OF COOLING APPLIENCES OF AREA UNDER GE MH AND RH KIRKEE
2020_MES_363919_3
8118/E8
Open Tender
Civil Works
Works
270 days
KIRKEE AND AUNDH
As per tender documents
6 documents required · 6 mandatory
₹500
Yes
GE MH AND RH
₹24,000
Yes
20 Feb 2021
3 Nov 2020
2 Dec 2020
3 Nov 2020
1 Dec 2020
17 Nov 2020
3 Nov 2020 - 10 Nov 2020
60 days
Amount
M & L for comprehensive maintenance and servicing of Split type Air conditioner / Window type unit of any capacity outer and inner unit both of any make including cleaning the dust from body with blower, cleaning of condenser and cooling coil, checking all connectins including functioning of metal clad socket/DP switch, function of relay, capacitors, overload protector, thermostat, fan motor, fan/blower drum, main control board PCB, electronic control box, etc, oiling/greasing of fan motor, checking serviceablility, cleaning of the air filter woolen felt & refixing ensuring for air tighting complete, repair and replacement of worn out/unserviceable spares including taking down and refixing, transportation to and from workshop if required and refixing it in its original place after fully servicing including testing & commissioning all as specified and directed by Engineer-in-Charge. (Note: (i) Spare parts replaced shall be measured & paid under separate item.
All as per item No 1 above but for Water cooler/Deep frezzer/Refrigerator of any capacity
Supply only starting capacitor 80-100 mfd for AC, Water cooler, Refrigerator, Deep freezer all as specified and directed on existing make.
Supply only running capacitor 10 Mfd to 25 Mfd
Supply only running capacitor 36 MFD
Supply only running capacitor 50 MFD
Supply only running capacitor 60 MFD
Supply only blower motor capacitor 4 Mfd to 6 Mfd
Supply only starting relay suitable for water cooler, AC and Refrigerator, Deep freezer for any make and model operated on single phase 230 volts all as specified and directed.
Supply only for over load relay comprising of over load protection suitable for air conditioer, water cooler, deep freezer and refrigerator operated in single phase 230 volt all as specifed and directed.
Supply only thermostat switch suitable for Air conditioner, water cooler, Deep freezer and Refrigerator operator on single phase 230 volts supply all as specified and directed.
Supply only drier filter for AC, water and Refrigerator.
Supply only magnetic contactor as in outer unit of Split type air conditioner as per existing type complete all as specified and directed.
Supply only capillary tubes for Air conditioner 1.5 Ton / 2 ton and water cooler 40 to 150 Ltrs
Supply only capillary tubes for Refrigerator & Deep freezer up to 400 Ltr
Repair and replacement, indoor fan motor of split type AC of any capacity
Supply only condensor fan motor 1300 rpm, 1/6 Hp, 1/8 Hp, 1/10 Hp for split type Air conditioner outdoor unit of 1.0 Ton/1.5 Ton/2.0 Ton as per existing make and capacity all as specified and directed by Engineer in charge
Supply only condensor fan motor double shaft 1/6 Hp, 1/8 Hp, 1/10 Hp for Window type AC of1.0/1.5 Ton/2.0 Ton as make and capacity all as specified and directed by Enginner in charge
Supply only condensor fan motor 1/36 Hp for water cooler of 40-80 Ltr and Deep freezer up to 400 Ltr as per existing make and capacity all as specified and directed by Engineer in charge
Supply only condensor fan motor 1/6 Hp, 1/8 Hp, 1/10 Hp for water cooler of 120-150 Ltr as per existing make and capacity all as specifed and directed by Engineer-in-Charge
Supply only blower/condenser fan blades as per existing make & type for Air conditioner/water cooler/Deep freezer all as specifed and directed.
Repair, replacement and supply, install, test & commissioning harmetically sealed New compressor for split type AC of capacity 1.5 TR duly charged with fresh gas R-22/ R-134 a complete all as specifed and directed by Engineer-in-Charge including taking down old u/s compressor. Make: Voltas/Shriram/LG/Godrej/Kirloskar or as per existing make at site.
All as per item No 22 above but for Split type AC of capacity 2.0 TR
All as per item No 22 above but for Window Type AC of capacity 1.5 TR
All as per item No 22 above but for water cooler of capacity 40 to 80 Ltrs
All as per item No 22 above but for water cooler of capacity 120 to 150 Ltrs
All as per item No 22 above but for Refrigerator 165 to 210 Ltrs
All as per item No 22 above but for Refrigerator 210 to 310 Ltrs
All as per item No 22 above but for Deep freezer upt 200 to 400 Ltrs
M & L for Detecting the gas leakage, rectifying the defects including repair to condensor coil/evaporator coil by means of welding, soldering etc, vacumizing and charging, topping up fresh gas R-22/ R-134 a and commissioning and testing for the 1.5 Ton/2.0 ton split /window type AC all as specified and directd by Engineer-in-Charge
All as per item No 30 herein above but of water cooler, refrigerator & Deep freezer of any type and capacity
Supply and replace remote control unit of Splity type AC 1.5 Ton / 2.0 Ton including making frequency arrangement of new remote with existing system all as specified and directed by Engineer-in-Charge
Supply only Electronic PCB unit for main control panel of splity type/window type AC of any capacity
M & L for servicing and replacing of unserviceable parts of water purifier / Aqua purifier of various capacity including replacing of filter cone, media etc all as specified and directed by Engineer-in Charge
M & L for comprehensive maintenance and service of colr room / walk in cooer unit outer and inner unit both of any make including cleaning the dust from body with blower cleaning of condensor and cooling coil, with castic soda, oiling t motor, cleaning of filter chekcing all electric connection all as speicified and directed by Engr-in-Charge. (Note: Spare parts shall me measured and paid under following item)
Replacement of electronic circuit board for walk in cooler
Replacement of defrosting timer 40 Amps rating to walk in cooler
Replacement of solenoid valve for cold room
Replacement of outdoor unit fan motor as per sample
Replacement of evaporator fan motor with blade of cold room outdoor unit as per make and model on existing at site
M & L for replacing unserviceable door lock assembly of cold room existing as per site directed by Engr-in-Charge
Replacement of bakelite connector block 30 Ampls
M & L for dismantling of existing unserviceable voltage stabilizer up to 1 KVA for repairs including replacement of relays, electronic voltage sensor circuits and meter, micro switch, indication light RC filters and other connected items for making functional as per the entire satisifcation of Engr-in-Charge and replace of unserviceable transformer and testing complete for following capacities:-
All as per item No 43 above but Up to 2 KVA
All as per item No 43 above but Upto 4 KVA
All as per item No 43 above but up to 5 KVA
Taking out unserviceable Outdoor Unit (Condensor coil, compressor, Fan motor, body) of splity type AC 1.5 Ton capcity and supply and fix only outdoor unit of split type AC 1.5 TON capacity complete with (body, compressor, fan motor, condensor coil, and etc) including gas charging and testing complete all as specified and directed by Engineer-in-Charge.
Taking out unserviceable Outdoor Unit (Condensor coil, compressor, Fan motor, body) of splity type AC 2.0Ton capcity and supply and fix only outdoor unit of split type AC 1.5 TON capacity complete with (body, compressor, fan motor, condensor coil, and etc) including gas charging and testing complete all as specified and directed by Engineer-in-Charge.
Taking out unserviceable Indoor unit (Cooling coil, Fan motor, body) of split type AC 1.5 Ton capacity and supply and fix only Indoor unit of Split type AC 1.5 TON capacity complete with (cooling coil, Fan motor, body and etc) including gas charging and testing cmplete all as specified and directed by Enginner-in-Charge.
Taking out unserviceable Indoor unit (Cooling coil, Fan motor, body) of split type AC 1.5 Ton capacity and supply and fix only Indoor unit of Split type AC 2.0 TON capacity complete with (cooling coil, Fan motor, body and etc) including gas charging and testing cmplete all as specified and directed by Enginner-in-Charge.
Disconnecting electrical /mechanically and lowering t the ground for repairing / over hauling the desert cooler including replacement of canvas grass/ woold wool pads and spray painting to body with one coats of anti corrisive red oxide primer for any make of desert cooler to make it fully functional including replacement of unserviceable / defective spare parts, transportation to and from, re-installation and testing on completion t the entire satisfaction of Engineer-in-Charge. Note: Spares replaced will be measured and paid under separate item.
M & L for Marking with Sticker size 8' x 3 ' and Name on it as "MES NO" on split/window type AC, Water cooler, Refrigerator, Deep freezer installed in various location at MH Kirkee, Stn workshop Kirkee, FOL Depot, Aundh Brigade units complete all as directd and specified by Engineer-in-charge.
Supply only water lifting pump 1/70 HP capcity, operated on single phase 230 volts with all accessories and testing complete to the entire satisfaction of Engr-in-charge.
Supply only fan motor of desert cooler of any capacity including supporting legs, nuts and bolts etc.
supply only fan blade with bush for desert cooler motor
Supply only electronic contorl circuit board (PCB) as per existing type for desert cooler
Supply only swing motor for air cooler
S & F metal plug tops for 2 pin and earth socket AC box of capacity 240 V, 20 A all as specified and directed.
Supply only PVC Flexible pipe 25 - 30 mm dia as in drain pipe suitable for water cooler outlet including taking down old unserviceable pipe of any size
S & F incl connecting sheet metal encosure with two pin and earth plug and socket complete, with one double pole MCB 20 Amp . Make: L & T/Hager/Schnedier
S & F Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule for 15mm bore dia
S & F in push tap self closing taps of size 15 mm of cast iron or malleable cast iron, galvanised, screwed for iron pipe or for water cooler
Supply and fix PVC connecting pipe with brass nuts and washers at both ends of length not exceeding 60 cms for connection of water coolers with taking down old pipe
M & L for wiring for circuit / submain wiring with earth wire of size 2 x 4.0 sqmm + 1 x 4.0 sqmm of FR LS-H PVC insulated copper conductor, singel core cable in surface drawing in and including PVC cassing capping all as specified and directed.
M & L for Framed work such as grills, gratings etc for water tanks, water cooler stand, AC unit supports, UPS battery stand and similar work conforming to Fe- 290 Gde-E-165 with two coat of synthetic enamelled paint over coat of red oxide primer all as directed and specified by Engineer-in-charge.
M & L for repair/ replacement to stainless steel waste water tray for any type/capacity water cooler including welding, polishing, riveting, provision of fixing screws and refixing
M & L for Gaskets for top cover for water cooler of any capacity and make as per site requirement
Taking out unserviceable cooling coil of any type of capacity refrigerator and S & F Cooling coil as per existing make and size all as specified and directred by Engr-in-Charge.
M &L for replacement damage condenser coil for refrigerator of any type/capacity
Supply only door switch for refrigerator of any type and any capacity
Supply only pigmy lamp (indoor lamp) as per existing type for refrigerator
Supply only freezer door as per existing make and type for refrigerator
Supply only timer switch assembly for refrigerator as per existing for capacity 210 to 310 Ltrs
M & L for carry out routine maintenance, leak testing & gas charging and servicing of package type air conditioner of capacity 7.5 TR including removing the dust from body with blower, cleaning the condenser and cooling coil, checking all the electrical and refrigeration piping connections, checking function of relay, capacitors, overload protector, thermostat, fan motor, blade, fan/blower drum, LT control panel, VFDs, electronic control box, etc, oiling/greasing of fan motor checking serviceability cleaning of the air filter woolen felt& refixing ensuring for air tighting complete repair and replacement of worn out/unserviceable spares including taking down and refixing, transportation to and from workshop if required and refixing it in its original place after fully servicing including testing & commissioning all as specified and directed by Engineer-in-charge. Note: 1 Spare parts replaces shall be measured & paid under separte item. 2. Gas required for testing and re-filling including quoted rate.
M &L for replacement of blower of package unit as per exisiting make and model with new one for 7.5 TR Air cooled package type AC plant
Supply only relay HP & LP for package type AC plant of capacity 7.5 TR
Supply only condensor fan motor, 230 V, 50 Hz 920 rpm 1/3 HP for package type AC 7.5 TR, on exisiting make all as speicifed and directed by Engr-in-charge.
Supply & fixing in replacement including connection 3 pole AC power contactor, 32 Amps, 415 volt with auxilary contact 1 NO + 1 NC, having coil voltage 380 to 400 volts make Simens cat ref C4NE22 or equivalent make of L & T /Havells
Supply, fixing and connecting in replacement Intigrated circuit board with all electgronic components suitable for 7.5 TR capacity Voltas package type Air conditioner
supply, fixing and connecting in replacement SPPR circuit board suitable for 7.5 TR capacity Package AC of make Voltas
Supply and fixing of 3 phase, 415 V, 50 Hz compressor of capacity 7.5 TR suitable for package type AC Make: Voltas
Supply and fixing of fan blade suitable for outdoor unit of capcity 7.5 TR
Supply and fixing of Blower motor suitable for Voltas make Ductable type AC of capacity 7.5 TR
Supply and fixing of Electronic PCB kit for control panel suitable for Voltas make Package AC of capacity 7.5 TR
Material and labour for shifting of split AC 1.5 TR & 2.0 TR with all accessoires and installed at new location, including fixing arrangement of indoor/outdor unit along with mounting bracket/Frame including cutting holes to wall and making good disturbed surfaces to match with the existing finish of walls etc complete all as shown and directed by Engr-in-charge. Note: Additonal copper tubing as required to make existing AC serviceable at new location shall be measured and paid separately. All other items are included in the unit rate quoted.
Supply only copper tubing for 1.5/2.0 TR split AC with proper insulation of suitable size and taking out old one as per directed by Engr-in-Charge.
SKS Electricals
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .