REPAIRS MAINTENANCE HT EXTERNAL ELECTRIC SUPPLY SYSTEM AT TECHNICAL AREA AT CVRDE AVADI.
2020_MES_367532_1
8324/E8
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
AVADI
As per NIT
8 documents required · 8 mandatory
₹500
AGE I RD AVADI
₹19,000
Yes
9 Sept 2020
8 Aug 2020
7 Sept 2020
8 Aug 2020
3 Sept 2020
20 Aug 2020
8 Aug 2020 - 20 Aug 2020
60 days
Amount
Excavation in trenches in hard/dense soil not exceeding 1.5 mtr wide and not exc 1.5 m depth for taking out/laying of UG cables and getting out all as specified and directed. Note: PCC Cover slab retrieved from excavation shall be cleaned and neatly stacked for reuse under item No. 5
Returning filling, including spreading leveling, watering and well ramming in layers not exc 25 cms thick of soil complete all as specified and directed.
Removing the surplus excavated material/soil to a distance not exc 50 mtrs and depositing, where directed at a level not exceeding 1.5 mtrs above the starting point all as specified and directed.
Supply and spread sand for cushioning top and bottom of the cable all as directed and specified.
Laying only PCC cover laying in trenches for cable protection complete all as specified and directed. Note : PCC cover available under relevant taking down item.
Supply and laying un-reinforced precast concrete cable cover class HV Type 1 flat size 300x180x40 MM all as directed.
Supply and fix in repair cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminum conductor cable of size 120 Sqmm to 185 Sqmm and testing complete all as specified and directed.
All as per item No.7 above, but for indoor type termination cold shrink type all as specified and directed.
Supply and fix in repair straight through jointing kit cold shrink type 11KV grade with jointing material and accessories suitable for 3 core XLPE armoured aluminum conductor cable of size 120 to 185sqmm incl testing all as directed. Note for item No 7,8&9 : Excavation for taking out cable(from loop) for termination shall be measured and paid under relevant items.
Supply and laying HT XLPE insulated, screened PVC bedded, galvanized steel strip or wire armoured, electric power cable ( heavy duty ) with aluminum conductor 11000 volt grade, cross sectional area 150 Sqmm, 3 core (earthed) conforming to IS-7098 (Part-I) laid in trenches / under floor / roads / along poles/ducts etc. all as specified and directed
S&F GI tubing light grade of size 80mm bore for protection of cables to be laid under roads, crossings/culverts incl taking down u/s GI pipe any type any size complete all as specified and directed.
Demolition of cement concrete (un-reinforced) in ground floors and paving not exceeding 15 cm thickness (below or above ground level ) complete all as specified and as directed
Taking down unserviceable LA, Supply and fix Lightning arrestors expulsion type with all fittings, transmission class, discharge capacity 10 KA(peak) suitable for 11000 Volts grade complete all as directed.
Material and Labour for preparation of old painted surfaces of indoor/outdoor type transformers body, HT/LT duct/two&four pole structure and HT Panel board at various substations for painting, applying one coat of spray paint with synthetic enamel paint of approved without distributing/damaging the electrical network system /equipment all as specified and directed.
M&L for writing / marking of ratings/incoming/outgoing details/SM Nos in capital English alphabet in thick paint n. exc. 30 cm complete all as specified and directed
Supply and fixed in repairs Danger notice plate of size 25 cm x 20 cm x 1.60 mm thick, mild steel sheet, vitreous enameled white, with letters, figures and conventional skull & bones in signal red colour and fixed with MS clamps made out of 25 mm x 3 mm MS flat iron including bolts and nuts of approved size for HT 11000 volts complete all as specified and directed.
S&F in replacement Cable route indicators (HT) made out of cast iron oval shape disc and supported with angle iron including PCC 1:3:6 (20mm graded aggregate) cable route indicator angle will be embedded with PCC not less than size 15cm x 15cm x 30cm in ground including earth work and all as specified and as directed
M&L for taking out HT cable any type and size and relay the cable after necessary rectification under relevant item in BOQ and testing complete all as specified and directed. Note: Earth work, RFR, removing, sand filling, laying of cover / Bricks and additional cable (if required) shall be measured and paid separately.
M&L for defect rectification in HT 11 KV cable laid in trenches by locating fault with the help of electronic fault locator machine comprising of surge generator pulse fault location with high frequency distance calculator etc. Excavation in any type of soil strata exposing the cable fault removal of deteriorated position of cable treating of cable and keeping the same ready for jointing work for cables of size up to 240 Sqmm 3core.
Notes for Srl. Item No.19 : (i) The contractor shall bring the fault locating equipment at site with in 02 hours of instructions received from Engineer -in- charge and he shall ensure that the fault is rectified with in 24 hours of receipt of intimation from Engineer-in-charge failing which recovery of Rs. 500.00 per hour shall be recovered from the contractors dues w.e.f the time immediately after the expiry of 24 hours duration.
(ii) For the purpose of payment one unit of “each job” shall comprise of detection of faults in a particular stretch of cable which are identified in that particular stretch , irrespective of number of defects / faults in that particular stretch which are detected during fault detection and the contractors unit rate quoted shall be deemed to include for the same and all such defects / faults which are detected in that particular stretch shall be considered as one unit. (iii) Joints, jointing materials and cable required shall be measured and paid for separately.(iv) The payment is not applicable for error fault finding location.
Taking proper shut down in writing and disconnecting the HT & LT connections of existing Indoor/Outdoor type transformer of capacity upto 1000 KVA mounted on 2/4 pole structure/plinth and transport to authorized workshop for repair and back to site after necessary repair/replacement of defective parts including installation in the same location and testing, complete, all as specified and directed. (i) Placing /removing standby transformer in the place of defective transformer under repair including loading/unloading, shifting including transportation and make the system/line functional will be the responsibility of the contractor, LT cables, switch gear and other connected items for temporary connection will be provided by the contractor. Contractor’s quoted rates shall be inclusive of all these factors.
Note for Item No. 20: (a) The quoted rate quoted for the item includes the following :- (i) Arrangement of manpower, tools and plants and Recovery vehicle for transportation and shifting of transformer to work shop and back. (ii) Toping up of transformer oil, replacement of transformer oil as required basis under intimation to the department. (Transformer oil will be measured and paid separately). (iii) Cutting/chipping of RCC/PCC plastering of foundation/platform and minor grill work/welding work. (iv) Winding material, labour and other items shall be measured and paid separately under respective items. (v) Contractor shall inform the department for inspection on the same day on receipt of repaired transformer from the workshop. (vi) Transformer shall be tested in presence of Engineer-in-Charge at workshop and after installation at site and test result shall be kept in record duly signed by all concerned. One day prior intimation shall be given to the Engr-in-Charge for testing. (Testing record will be prepared by contractor and signed by Engr-in-Charge). (vii) Any loss/damage occurred to transformer in all respect during transportation/ installation shall be made good by the contractor at no cost to department.
M&L for rewinding of LT/HT coil conforming to the original winding of the transformer of any make/capacity with DPC cooper wire/strip super enameled of high quality matching with existing impedances and providing class ‘E’ insulation suitable for transformer Up to 1000KVA complete, all as specified and directed by Engr-in-Charge. Make of copper : Atlas/Devidayal. Note for items No 21:- The rate quoted is deemed to be included in the unit rate for varnishing,sleeving and insulating materials.
S&F in replacement of LT bush assembly brass complete with double check nuts, washers and oil seal all accessories with bushing insulators for transformer 50 to 300 KVA
S&F in replacement of LT bush assembly brass complete with double check nuts, washers and oil seal all accessories with bushing insulators for transformer 400 to 1000 KVA
S&F in replacement of HT bush assembly brass complete with double check nuts, washers and oil seal all accessories with bushing insulators for transformer 50 to 300 KVA
S&F in replacement of HT bush assembly brass complete with double check nuts, washers and oil seal all accessories with bushing insulators for transformer 400 to 1000 KVA
Taking out the unserviceable breather assembly complete form indoor/outdoor type transformer capacity up to 2000KVA and supply and fixing the new breather assembly complete filled with fresh blue silica gel including connecting with proper rubberized gasket complete al as specified and directed
S&F new silica gel complete all as directed.
M& L for Purification, filtration and Dehydration of transformer oil of transformer installed at various indoor/outdoor sub station by ultra high vacuum filtration machine with stream line filtration plant at a temp 60 to 70 deg. Celsius and achieving minimum dielectric withstand strength of 60 KV for 1 minute in 2.5 mm gap setting (for used oil) complete all as specified and directed by Engineer-in-Charge. Note: (i) Contractor shall ensure no wastage of transformer oil. (ii) Oil required for topping up the transformer will be measured & paid separately.(iii) Contractor shall be ensure that the conservator tanks are full to its level before starting the dehydration
Supplying and filling new mineral grade transformer oil EHV type confirming to IS-3357 to 1983 for filling and for topping up in transformer/Voltage stabilizer duly filtered with filer plant to obtain high dielectric not less 60KV (Gap 2.5mm) complete all as specified and directed by Engineer In charge.
M&L for Servicing HT VCB panel cum breaker 800/630A 13.1KA rating Indoor type make of SEIMENS/ CROMPTON/SCHINDER after taking proper shut down and disconnecting the cables from panel draw out VCB breakers, checking&calibration of over fault relay, earth fault relay, checking alignment of VCB isolating contact, servicing of operating mechanism including tripping and closing system of the breakers, dehydrating, decarburizing of panel, bus bar section & circuit section including incoming/ outgoing cables, provide necessary HT insulation at joints. Removing perished monoplus compound cleaning and re-insulating with HT taps wherever necessary, with and including replacement of worn-out/defective spares like tension springs, torsion springs, nut bolts, washers of suitable size, lingers and de-carbonizing all joints, bus bar, CTs, PTs spout metal parts and making VCB perfect operation in manual and electric mode including all routine and preventive maintenance of breaker under the supervision of authorized dealer /representative and reconnecting the panel/breaker in its original position and testing all as specified and directed.
Note: - (i) The rate quoted inclusive of all minor spares etc. (ii) Spares parts required other than mentioned here-in-after shall be deemed to be included in the quoted rate. (iv) The calibration test certificate to be submitted after servicing & testing.
Supply only shunt trip coil 220/110 or 30Volts DC
Supply only closing trip coil 220/110 or 30Volts DC
Supply only bus bar insulator 11KV complete all as specified and directed.
Supply only contact system for VD4-630A suitable for SEIMENS/CROMPTON/SCHINDER make HT breaker
Supply only Aux switch suitable for SEIMENS/CROMPTON/SCHINDER make HT breaker
Supply only spring drum suitable for SEIMENS/CROMPTON/SCHINDER make 11KV HT breaker
Supply only spring V4207 suitable for SEIMENS/CROMPTON/SCHINDER make 11KV HT breaker
Supply only Roller chain V4208 suitable for SEIMENS/ CROMPTON/ SCHINDER make 11KV breaker
Supply only Tension spring suitable for SEIMENS/CROMPTON/SCHINDER make 11KV HT breaker
Supply digital ammeter measuring range 0 to 100A capacity complete all as specified and directed
Supply only motor cut off switch suitable for SEIMENS/CROMPTON /SCHINDER make 11KV HT breaker
Supply only ‘On Off’ indicator (display) suitable for SEIMENS/CROMPTON /SCHINDER make 11KV HT breaker
Supply only panel space heater 80W complete all as specified
Supply only spring charging motor suitable for SEIMENS/CROMPTON /SCHINDER make 11KV HT breaker
Supply only HT self fusing tape insulation heavy duty suitable for insulation of 11KV bus bar make Scapa/3M/Stanbac
Supply only insulation adhesive Urethane isolation suitable for air drying conformal for coating in Electricals equipments, battery terminals,11KV bus bar etc in 300ml bottle complete all as specified and directed.
Supply only vacuum interrupter 800/630A 11KV rating suitable for SEIMENS/CROMPTON/SCHINDER HT breaker
S&F in replacement of current transformer (CT) ratio 200/100-5A, 50Hz, 15 VA accuracy class-I &5P-10,short cut time 18.4KA for 1 sec,as per IS-2705 epoxy type suitable for 11KV,VCB breaker including all necessary fixing arrangement and proper wiring connection complete all as specified and directed.
S&F in repair Pin Insulator 11KV at 2/4pole 11KV structure unit complete all as specified and directed
S&F in fuse element 20A-50A at 2/4pole 11KV structure unit complete all as specified and directed.
M&L for checking Insulator, lightning arrestor and tightening/replace aluminum jumbler connection complete at 2/4 pole 11KV structure complete all as specified and directed.
Supply and laying/spreading 40 mm graded gravel(stone aggregate) 40mmthick, bedding thickness of 100 to 150mm in any position at electrical 2/4 pole structure all as directed.
M/s GM Constructions
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .