Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.9 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹15.9 L+₹87,266 (5.82%)Rejected-Finance SHOP NO 259 LOHOGAON ROAD KALWAD KHANDVE NAGAR PUNE 411032 | PUNE | MAHARASHTRA | 411032 | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹16.7 L+₹1.7 L (11.1%)Rejected-Finance NOT SPECIFIED | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹17.5 L+₹2.5 L (16.9%)Rejected-Finance FLAT NO 601 TOWER NO 30 SECTOR NO 21 AMANORA PARK TOWN HADAPSAR PUNE 411028 | PUNE | MAHARASHTRA | 411028 | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹17.6 L+₹2.7 L (17.7%)Rejected-Finance | L5 | Rejected-Finance Not Lowest |
Tender Value
₹19.3 L
EMD Value
₹38,686
Closing Date
25 Dec 2019, 6:00 pmClosed
CWE Pune
HEADQUARTERS COMMANDER WORKS ENGINEERS GEN CARIAPPA MARG, PUNE-411 001
85777PROVN OF 01 X 300 KVA TRANSFORMER WITH ACCESSORIES FOR COMMAND HOSPITAL (SC) PUNE, REPLACEMENT OF EXISTING FALSE CEILING LIGHTS WITH NEW PATTERN LED FALSE CEILING LIGHTS IN BLDG NO P71 (SHIVAJI HALL) , PROVN OF UNDER GROUND POWER CABLE CONNECTI
2019_MES_259966_2
85777PROVN OF 01 X 300 KVA TRANSFORMER WITH ACCESS
Open Tender
Electrical and Maintenance Works
Item Rate
90 days
GE South Pune
As per Tender
9 documents required · 9 mandatory
₹500
GE South Pune
₹38,686
Yes
3 Feb 2020
18 Dec 2019
27 Dec 2019
18 Dec 2019
25 Dec 2019
20 Dec 2019
Amount
Supply ,installation test and commissioning, transformer step down of capacity 315 KVA, BIS (ISI ) MARKED complete with all standard fitting , 11/0.433 KV three phase, copper wound IN DOOR type distribution transfomer conforming to IS -1180 part-(I) 2014 Level II double wound oil immersed , naturally cooled with external cooling tubes, core type delta connected on primary HT side, and star on LT side manual type load tap chagning facility on HT side to vary secondary voltage from at 2.5% to +7.5% to be chagned by means of hand operated off load tap chagning,including first filling of transformer oil of suitable die- electric strength including standard accessories as per ISand making connection on HT and LT side etc including dismantling existing foundation from the room and reconstructing new foundation of pcc as per Specification of manufacture to with stand the load of 315 KVA TRANSFORMER and making good the disturbed area as existed all as specifeid and directed by Engrs in Charge
Supply & laying and testing XLPE insulated screened , PVC bedded,galvanised steel wire armoured electric power cable(heavy duty) with aluminum conductor XLPE insulated screened PVC bedded galvanised of 11000 volts, (Earthed ) grade cross sectional area 120 sqmm 3 core.complete all as specified and as directed.
M&L for laying of half round reinforced concrete pipe, of dia 180 mm, half round for bottom and half round for top. an before laying excaved area shall be leveled. complete all specified and directed. Note : 01 Half round top and 01 half round bottom together will be considered as one running meter.
M&L for laying of Reinforced concrete pipes,class NP2 with one collar per lengh of pipe of dia 150mm ,full round and before laying exacaved area shall be leveling complete all as specified and as directed.
Excavation in trenches n. exc 1.5 m wide and n. exc 1.5 mtr depth n exc 10 sqm on plan and getting out in sof/loose soil complete all as specified and as directed.
Excavation in trenches n. exc 1.5 m wide and n. exc 1.5 mtr depth n exc 10 sqm on plan and getting out in Hard/Dense Soil complete all as specified and as directed.
Returning filling in including spreading, levelling, watering and well ramming in layers n.exc. 25cm in soils complete all as specified and as directed.
Removing excavated material to a distance not exceeding 50mtr and depositing where directed at a level not exceeding 1.5mtr above the starting point complete all as specified and as directed.
M and L Earthing complete with galvanised 'steel earth plate electrode 600×600× 6.3mm thick, buried 'directly in ground (earth pit not less 'than 2.25 metres deep below normal ground 'level) with top edge of the plate not 'less'than 1.5 metres below normal 'ground level, connected to 'galvanised iron strip 32x6mm by means of bolts, nuts, check 'nuts and washers of galvanised iron 'or steel . earth strip protected by provision of GI medium grade pipe 40mm dia including provision of concrete pit in PCC (1:2:4) type B1 using 20mm graded stone aggregate with 40mm thick RCC cover in 1:2:4 type B1 reinforced with XPM (weight not less than 4 kg/sqm) and frame made out in MS angle iron of size 25x25x3mm with lugs 02 Nos and with MS handle made in 6mm dia round bar made to shape, including GI medium grade 20mm bore pipe for watering, perforated at bottom 1.75m long placed on top edge of earth plate including including provision of mixture of charcoal dust & common salt packed upto minimum 150 mm all around the earth plate, test point and with fixing arrangement ,funnel, wire mesh and earth work in hard/dense soil returning filling in and removal of surplus soil to a distance not exceeding 50mtr all as shown in electrical plate No. 3 of SSR Part I 2009 connected to earthing test 'point all as specified or indicated 'including testing on completion.NOTE:-GI strip and GI pipe 40mm bore medium grade for encasing GI strip beyond 7.50m length per earthing if so required at site shall be measured and paid separately under relevant items.
M&L for main earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or burried in ground or drawn in pipe for loop earthing etc of galvanised strip 32 x 6 mm all as specified and directed
Supply and fix cable jointing kit for 11KV grade cable for OUT DOOR type termination cold shrink type joint complete with jointing material such as lug etc and accessories suitable for 3 core XLPE armoured Al conductor cable of size 3 core 120 sq mm complete all as specified and as directed.
Supply and fix cable jointing kit for 11KV grade cable for IN DOOR type termination cold shrink type joint complete with jointing material such as lug etc and accessories suitable for 3 core XLPE armoured Al conductor cable of size 3 core 120 sq mm complete all as specified and as directed.
Supply and fix 80 mm bore GI pipe light grade with fitting and special for protection of cable and fixing to the existing pole / laid in trench etc with flat iron clamp 25x3 mm including nut and bolt and washer etc complete all as specified and as directed.
Taking down aluminium point wiring( light, fan, socket or power) complete, including fixtures and fittings such as switches, ceiling roses, pendants holder,regulators sockets, light fitting etc removing materials deposited to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc.complete all as specified and as directed.
M&L for point wiring of any length using approved colour coding as per IS,with stranded copper conductor 1.5 Sq.mm(Nominal area),single core,PVC insulated and unsheathed stranded cable 1100 volts grade,ISI - 694 marked in and including heavy duty,PVC casing caping including all accessories etc.,heavy duty ISI marked,with mild steel concealed sunken boxes with earth dolly with laminated bakelite sheet of min. thickness of 3mm suitable for switches/sockets,etc,including PVC insulated stranded copper conductor 1.5 Sq.mm (nominal area) single core cable as earth and connecting to earth dolly complete and including cutting and chases in the wall for box and all as specified for the following:- Note:- Making good of disturbed surfaces will be done by contractor without any claims.
(a) One light/fan/ point controlled by one switch and regulator.
S&F piano type switch 5 amps single pole,240 volts complete all as specified and as directed.
S&F ceiling rose surface type three terminals,240 volts.complete all as specified and as directed.
S&F in replacement of smart glow recess mounting LED 2'x2' luminaries of 36 Watt with an inbuilt integrated PIR sensor, White acrylic drop light dissipator, white powder coated CRCA housing with LEDS, Plane front frame fixed to housing, Concave acrylic diffuser with 3500 LM--100L / W,THD 10% ( +/- 5% ) and rated supply voltage -140-270 Volt, conforming to Cat Part No RC 383B LED 365-6500 PSU OD WH PIR of Phillips Make or of equivalent make in Jaguar / Wipro complete all as specified and as directed.
Supply, lay, test, connecting and commissioning of size 95 Sqmm 3.5 core under ground armoured cable, LT 1100 volts grade, heavy duty XLPE insulated, with aluminium stranded conductor complete laid in trenches/fixed to poles/drawn through pipes with suitable size cable glands crimping type cable lugs etc all as specified and directed . complete all as specified and as directed.
M and L Earthing complete with galvanised 'steel earth plate electrode 600×600× 6.3mm thick, buried 'directly in ground (earth pit not less 'than 2.25 metres deep below normal ground 'level) with top edge of the plate not 'less'than 1.5 metres below normal 'ground level, connected to 'galvanised iron strip 25x4mm by means of bolts, nuts, check 'nuts and washers of galvanised iron 'or steel . earth strip protected by provision of GI medium grade pipe 40mm dia including provision of concrete pit in PCC (1:2:4) type B1 using 20mm graded stone aggregate with 40mm thick RCC cover in 1:2:4 type B1 reinforced with XPM (weight not less than 4 kg/sqm) and frame made out in MS angle iron of size 25x25x3mm with lugs 02 Nos and with MS handle made in 6mm dia round bar made to shape, including GI medium grade 20mm bore pipe for watering, perforated at bottom 1.75m long placed on top edge of earth plate including including provision of mixture of charcoal dust & common salt packed upto minimum 150 mm all around the earth plate, test point and with fixing arrangement ,funnel, wire mesh and earth work in hard/dense soil returning filling in and removal of surplus soil to a distance not exceeding 50mtr all as shown in electrical plate No. 3 of SSR Part I 2009 connected to earthing test 'point all as specified or indicated 'including testing on completion. NOTE:-GI strip and GI pipe 40mm bore medium grade for encasing GI strip beyond 7.50m length per earthing if so required at site shall be measured and paid separately under relevant items.
M&L for main earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or burried in ground or drawn in pipe for loop earthing etc of galvanised strip 25 x 4 mm complete all as specified and as directed.
Rama Electricals
United Sales Corporation
UNIQUE ENGINEERS
PAMS ENTERPRISES
M/S - SUJIT ELECTRICALS
CHAITANYA WINDWELL
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .