Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.3 LAccepted-AOC | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹9.2 L+₹1.7 L (23.1%)Rejected-Finance | L2 | Rejected-Finance Being not lowest |
Tender Value
₹9 L
EMD Value
₹18,000
Closing Date
25 Feb 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Shri Pranav, AGE (I)
AGE (I) Manauri Prayagraj-212212
REPAIR/MAINT OF PACKAGE TYPE ACs AND OTHER ALLIED SERVICES FOR TECH AREA AT AF STN MANAURI
2023_MES_576404_1
9052/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Manauri
As per Tender documents
7 documents required · 7 mandatory
₹500
AGE (I) AF Manauri
₹18,000
Yes
22 Mar 2023
21 Jan 2023
27 Feb 2023
21 Jan 2023
25 Feb 2023
7 Feb 2023
Amount
M&L for servicing of Ductable Package type Air cooled AC of 10/11 TR (Refrigerant- R407) capacity including cleaning condenser and cooling coil with air blower to remove the impurities dust and foreign materials, cleaning of filters of suspended indoor unit, refixing the same after complete repair/servcing with replacement of unserviceable parts and carry out check necessary brazing work to copper tubing and charging the refrigerant as per existing/NON-CFC class complete for 11 TR capacity Ductable package type AC, replacement of all unserviceable/burnt out electric cable thimbles/connector of the unit and descalling by using antiscallent solution passing through copper tube of condensor units and connected pipes/tubes with suitable tools and pressure pumps, including painting of condensor unit with two coats of enamel paint of the colours complete all as specified and directed. Make: Blue Star, Model XWCS2026AR2 installed at EDP Bldg and T-60. Note: The cost of required Tools & Plants, Chemicals and refrigerant deemed to be included in the quoted rate.
S&F in replacement PCB suitable for 11 TR capacity Ductable package type Air conditioner of existing make and model complete all as specified and directed.
M&L for rewinding the electric motor of capacity 2 HP by dismantling and removing the burnt out copper winding cleaning the slot of stator thoroughly and rewinding the stator with super enamelled copper winding wire of same gauge with proper class of insulation and applying varnish including re-assembling all the parts of the motor, reinstallation in same position including testing and comissioning complete all as specified and directed.
S&F in replacement multicore round PVC insulated and FRLS PVC round sheathed copper conductor (flexible) industrial cable 1100Volts 4 Sqmm 3 core complete all as specified and directed. Make: Havells / Finolex / Polycab
M&L for repair to leaking area of AC Plant of any capacity, including pressure testing, dehydration and gas charging R-407C/R-410 including with cutting soldering repairing to leakage etc complete making serviceable complete all as specified and directed. Note: Empty/filled gas cylinder shall be the responsibility of contractor and he shall be liable for all risk against the same and all cost deemed to be included in the quoted rate.
M&L for repair to leaking area of Vertical type air conditioner of any capacity, including pressure testing, dehydration and gas charging R -22/R-32 including with cutting soldering repairing to leakage etc complete making serviceable complete all as specified and directed. Note: Empty/filled gas cylinder shall be the responsibility of contractor and he shall be liable for all risk against the same and all cost deemed to be included in the quoted rate.
S&F in replacement filter drier suitable for 11 TR AC plant complete as per existing complete all as specified and directed.
S&F replacement contactor 3 pole with AC Coil 40 Amps 415 volts duty rating at 415 V, 50 Hz, Type HGS 40, confirms to IS/IEC 60947-4-1, protection degree IP 20 fixed in existing panel. Make: SIEMENS / LEGRAND / L&T / ABB / SCHNEIDER / GE POWER
S&F in replacement Auto switch single phasing preventor complete all as specified and directed. Make: Minilec(VSP-2) / L&T / Siemens
S&F in replacement Aluminium Fan blade 27"(inch)(700mm) long for cooling tower of AC plant as per sample complete all as specified and directed.
M&L for shiftting of outdoor unit of Package type AC capacity upto 5.5 TR including copper tube as per existing size, PCC 1:3:6 type C1(using 20mm gradred crushed stone aggregate) work for out door mounting unit with nut bolt washer, gas- re-filling, leakage reparing, soldering etc complete all as specified and directed. Note: The quoted rate in this item shall be deemed to inclusive of T&P required for shifting.
M&L for servicing of vertical type tower/split AC of Make-Blue Star of 4.50/5.50 TR (Refrigerant-R22) capacity including cleaning condenser and cooling coil with air blower and water pressure pump to remove the impurities dust and foreign materials, cleaning of filters of suspended indoor unit, refixing the same after complete repair/servcing with replacement of unserviceable parts and carry out check necessary brazing work to copper tubing and charging the refrigerant as per existing/NON-CFC class complete for 4.50 TR capacity vertical type AC, replacement of all unserviceable/burnt out electric cable thimbles/connector of the unit and descalling by using antiscallent solution passing through copper tube of condensor units and connected pipes/tubes with suitable tools and pressure pumps, including painting of condensor unit with two coats of enamel paint of the colours and write MES/SM No or Company Srl No complete all as specified and directed. Notes: The cost of required Tools & Plants, Chemicals and refrigerant deemed to be included in the quoted rate.
S&F in replacement terminal block 6 way suitable for connection of cable including suitable size connector as per existing size complete all as specified and directed. Make: Havells Cat part No ICELPSMX001 / L&T / Indoasian.
S&F in replacement 3 pole power contactors capacity 32 Amp, duty rating at 415 V, 50 Hz, Type HGS 32, confirms to IS/IEC 60947-4-1, protection degree IP 20 complete all as specified and directed. Make: Havells / L&T / Indoasian.
S&F in replacement outdoor condensor coil copper type suitable for 4.5 TR outdoor unit for vertical type air conditioner complete all as specified and directed. Make: Blue star / Voltas / Hitachi. Note: Contractor should be submit the guarntee period of condensor coil and OEM purchase voucher to department.
Supply, installation, testinng and commissioning in replacement of Hermetically sealed scroll/Dual Rotary type compressor 3 phase 415 Volts 50 Hz of capacity 4.5 TR with connecting suction, discharge line by jointing with copper rod and oxyzen flame and making electric connection and wiring with microprocessor control panel and sensor complete all as specified and directed. Make: Copeland / Accel / Blue Star / Voltas or other make as approved by AGE(I) Note : (i) The cost of hiring of technician from the OEM of compressor for installation & commissioning including all T&P shall be included in Quoted rate. (ii) The cost of any other sensing/protective device equipment required to make the plant functional related to compressor shall be included in quoted rate. (iii) Contractor shall be provided the test certificate and warranty card issued by original manufacture for all compressor covered under this schedule.
Supply, installation, testing and commissioning in replacement of Hermetically sealed scroll/Dual Rotary type compressor 3 phase 415 Volts 50 Hz of capacity 5.5 TR with connecting suction, discharge line by jointing with copper rod and oxyzen flame and making electric connection and wiring with microprocessor control panel and sensor complete all as specified and directed. Note: (i) The cost of installation & commissioning including all T&P shall be included in Quoted rate. (ii) The cost of any other sensing/protective device eqpt required to make the plant functional related to compressor shall be included in quoted rate. (iii) Contractor shall be provided the test certificate and warranty card issued by original manufacture for all compressor covered under this schedule.
M&L for insulating the AC Plant Ducting Indoor in repair with Nitrile Rubber Minimum Thickness 13 mm, Instant Duct Seal Air-Drying Adhesive in between Nitrile Rubber Sheet and Metal duct outer surface, all in prescribed ratio complete all as specified and directed. Make: ArmaFlex Class 1 / Aerocell Class O / K- Flex / Armaflex Duct Seal Air-Drying Adhesive
S&F in replacement of propeller type condenser fan blade suitable for outdoor unit of capacity upto 4.5 TR as per sample complete all as specified and directed.
S&F in replacement stainless steel fan guard grill for condensor fan suitable for outdoor unit of capacity upto 4.5/5.5 TR as per sample complete all as specified and directed.
Supply, installation and testing indoor unit for vertical type air conditioner capacity 4.50 TR, 415 volts, 50 Hz, 3 phase, turbo cool, wide angle, power full air flow 2 way swing, Anti corrosive gold fins in indoor units, blower motor, PCB kit, remote control, communication cable from out door unit to indoor unit with all accessories as per OEM specification including taking down old unserviceable indoor unit capacity 4.50 TR complete all as specified and directed. Make: Blue Star / Voltas / Carrier Note: (a) Unserviceable Indoor unit should be deposited at E/M store yard. (b) Contractor should be submit the guarntee period of indoor unit and OEM purchase voucher to department.
Supply, Installation and testing out door unit for vertical type air conditioner capacity 4.50 TR, 415 Volts, 50 Hz, 3 phase, nominal current rating 8.50 Amp, compressor capacity 4.50 TR, Dual rotary type, Refrigerant R-32, Net dimension 1075 x 950 x 470 mm, outdoor noise level 73 db (A), power supply copper cable 5 core 2.50 Sqmm including copper cable 4C 1.50 Sqmm, suction tube size 3/4" (19.05 mm) - 5 m, Liquid tube size outdoor diameter 3/8" (9.52 mm) - 5 m, with all accessories as per OEM specification including taking down old unsv outdoor unit capacity 4.50 TR complete all as specified and directed. Make: Blue Star / Voltas / Carrier Note: (a) Unserviceable outdoor unit should be deposited at E/M store yard. (b) Contractor should be submit the guarntee period of outdoor unit and OEM purchase voucher to department.
M&L for fabrication of MS Angle iron in replacement for Tower air conditioner outdoor stand out of equal angle iron of size 45 x 45 cm and 0.5 cm thick of suitable size for installation of outdoor AC unit including grouting in PCC 1:3:6 type C1(using 20mm gradred crushed stone aggregate), nut bolts and painting including demolition of existing PCC complete all as specified and directed.
S&F in replacement copper capillary tube (suction tube) outer dia size 3/4" (19.05mm) complete with insulation suitable for 4.50 TR Tower AC complete all as specified and directed.
S&F in replacement copper tube (liquid tube) outer dia size 3/8" (9.52mm) with insulation suitable for 4.50 TR Tower AC complete all as specified and directed.
S&F in replacement condensor coil motor, heavy duty air fan motor capacity 1/3 HP single phase 2 Amps 920 RPM 250 watt, including suitable size of fan blade suitable for outdoor unit Tower AC capacity 4.50 TR complete all as specified and directed.
S&F in replacement blower fan motor, single phase synchronous motor 220V-240V, 50 Hz, 120 watt, 1.36 Amp, 920 RPM including suitable size of fan blade suitable for indoor unit Tower AC capacity 4.50 TR complete all as specified and directed.
S&F in replacement capacitor 55/60 MFD, 440 volts with aluminium terminal suitable for vertical type Air conditioner complete all as specified and directed.
S&F in replacement capacitor 36 MFD, 440 volts with aluminium terminal suitable for vertical type Air conditioner complete all as specified and directed.
S&F in replacement capacitor 10 MFD, 240 volts suitable for condensor fan motor of vertical type air conditioner complete all as specified and directed.
S&F in replacement capacitor 6 MFD, 240 volts suitable for condensor fan motor of vertical type air conditioner complete all as specified and directed.
S&F in replacement MCB TPN 240 Volts 10 KA 'B' series capacity 40 Amp with all incoming/outgoing connection with proper size lugs complete all as specified and directed. Make: Havells / Legrand / ABB / Indoasian
S&F in replacement industrial socket in sheet enclosure 32 Amp three phase (3P+N+E) 415 volts ISI marked with top plug in existing specification including making all connection complete all as specified and directed. Make: Havells Cat part No DHDPBEN032 / Legrand / ABB / Siemens
S&F in replacement Metal plug to 32 Amp three phase 240 volts 3 pin vertical mounting complete all as specified and directed. Make: Havells Cat Part No DHQSB34032 / Legrand / ABB / Siemens
S&F in replacement MCCB 4 pole, TPN 63 Amp rating having breaking capacity of 25 KA at 415V adjustable thermal and fixed magnetic setting type Ics=75% Icu, confirm to IS/IEC : 60947-2 complete all as specified and directed. Make: Legrand / Havells / Indoasian / HPL
S&F in replacement MCCB 4 pole, TPN 250 Amp rating having breaking capacity of 36 KA at 415V adjustable thermal and fixed magnetic setting type Ics=100% Icu, confirm to IS/IEC : 60947-2 complete all as specified and directed. Make: Legrand / Havells / Indoasian / HPL
S&F in replacement drain out pipe of size 25 mm PVC flexible for Air conditioner water drain pipe complete all as specified and directed.
S&F in replacement 5 way terminal block suitable connection of circuit of outdoor or indoor unit including suitable size lugs complete all as specified and directed.
M&L for dismentling of Indoor and outdoor Tower AC 5.5 TR along with all accessories and re-install, testing and commissioning indoor and outdoor unit of Tower AC capacity upto 5.5 TR including copper tube as per existing size, gas charging after finding of leakage, outdoor suitable size mounting unit with nut bolt washer and PCC work/brick work complete all as specified and directed. Note: The quoted rate in this item shall be deemed to inclusive of Gas Charging, copper tube and PCC work with outdoor stand.
M&L for providing sub main wiring in replacement with four single core 06.00 Sqmm (nominal area) PVC Insulated flame retardant unsheathed multi stranded copper conductor cable 1100 volts grade drawing through PVC conduit on surface of wall complete including 06.00 Sqmm PVC insulated unsheathed multi stranded flame retardant single core copper conductor cable for earth wire including taking down/removing old sub main wiring and making good distrubed surfaces of walls, floors etc complete all as specified and directed. Note: (i) Four runs of single core 06.00 Sqmm multi stranded copper cable and one run of 6.00 Sqmm earth wire and PVC conduit medium grade 25 mm including with tees, elbow, bends with all accessories shall be measured as one run length. (iii) Extra length of cable required for connection to DBs/MCBs shall deem to be included in unit rate quoted by contractor against the item. (iv) Earth wire run inside the conduit.
Note :- (i) Credit shown in credit schedule of tender document shall be considered by the tenderer while quoting the rates of various items. The same shall be recovered from various payment to contractor before handing over old material. The contract amount shall be arrived at after deduction of Schedule of Credit from the total quoted amount in BOQ. (ii) Make of material shall be as per mentioned in Particular specifications or Appendix 'B' to Particular specifications as approved by AGE (I) AF manauri if not specified in BOQ
A R ENTERPRISES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .