Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.6 LAdmitted-Finance 57 B FEEDER ROAD GROUND FLOOR 57 B FEEDER ROAD BARRACKPORE NORTH 24 PARGANAS WEST BENGAL 700120 | 24 PARAGANAS NORTH | WEST BENGAL | 700120 | ₹17.6 L | L1 | Admitted-Finance |
| 2 | L2₹30.1 L+₹12.5 L (70.8%)Admitted-Finance 9 8F RAM MOHAN BERA LANE KOLKATA WEST BENGAL 700046 | KOLKATA | WEST BENGAL | 700046 | ₹30.1 L+₹12.5 L (70.8%) | L2 | Admitted-Finance |
| 3 | Rejected-Technical 217 TILJALA ROAD TILJALA ROAD KOLKATA TILJALA ROAD KOLKATA WEST BENGAL 700046 KOLKATA WEST BENGAL 700046 | KOLKATA | WEST BENGAL | 700046 | - | - | Rejected-Technical DISQUALIFIED AS PER TENDER DOCUMENT |
| Sl No | Description | Qty | Unit | SATYA AIRCON AND ENG SERVICES PRIVATE LIMITED L2 | ALPHA GAMMA AIR SOLUTIONS PVT. LTD. L1 |
|---|---|---|---|---|---|
| 1.00Supply, Installation, Testing & Commissioning of Air Cooled type outdoor units of VRF system having hermetically sealed inverter scroll/twin rotary compressor, condenser coil fabricated from Seamless Copper tube & Plate type Al. Fins of Multi Row, Axial Flow, top discharge throw condenser fan, Condenser fan - motor unit, all system controls-safety. The system should have flexibility to handle total 280 Rmt of ref. piping. ODU shall be placed on structure with heavy duty anti vibrational pad to protect the system from any kind of unwanted vibration. The system shall have minmum COP of 3.7 at ARI condition as per CPWD guidelines. Each Outdoor units with High Pressure switch, Fan driver overload protector, Over current relay, Inverter Overload Protector & Fusible Plug. The unit shall be suitable for 415 ± 10 % volts, 50 Hz, 3 phase AC supply, and IP protection will be suitable for outdoor installation. The VRF System shall have green ref. gas only- R410A/ R407 | |||||
| 1.01 | 24 HP | 1 | No. | 5,99,620 ₹5,99,620 Lowest | 11,40,000 ₹11,40,000 |
| 2.00Indoor Units Supply, Installation, Testing & Commissioning of Indoor units address setting and capacity as mentioned below. Multi speed motor, coil section with DX coil, outer cabinet, drain pan mechanism insulation, pipe connections, clamp metal, washer fixing plate, sealing pads, screws, clamps, washer for hanging bracket & insulation for fitting, fresh air intake connector for cassettes etc. of various capacities as per specifications. Power cabling (3mtr from unit) with conduit from power socket & plug top to indoor is inclusive of price. | |||||
| 2.01 | Hi-Wall Type Indoor Unit - Capacity - 2.0TR | 8 | Nos. | 27,930 ₹2,23,440 | 25,000 ₹2,00,000 Lowest |
| 2.02 | Mid High static Ductable Type Indoor Unit With Remote Control - Capacity – 4TR | 2 | Nos. | 51,953 ₹1,03,906 | 48,000 ₹96,000 Lowest |
| 3.00VRF Y JOINTS FOR BRANCH DISTRIBUTION REFRIGERENT PIPE JOINTS WITH PRECAST INSULATION | |||||
| 3.01 | Supply, installation, testing & commissioning of Y shape Branch Distribution Joints for VRF system. ( The quantity shown here is indicative - in case the quantity requirement is differ based on the system selection for the specific product the revised quantity is required to quoted here) | 10 | Nos. | 6,808 ₹68,080 | 5,000 ₹50,000 Lowest |
| 4.00REMOTE CONTROLLER | |||||
| 4.01 | Supply, installation, testing & commissioning of Cordlesss remotes for VRF indoor units | 10 | Nos. | 1,210 ₹12,100 | 1,000 ₹10,000 Lowest |
| 5.00SITC of VRF Refrigerant Piping: Supply, installation, testing & commissioning of Seamless heavy gauge Copper piping of following size duly insulated with 13 mm/ 19mm thk. Nitrile Rubber Insulation covered with aluminium foil ( As per Specified with K Value of 0.027-0.029 K Cal/Hr.M Deg C at 0-16 Deg C) . Refrigeration piping will have to be taken in the piping rack / Support individually connecting to all indoor units for the respective floors. Even necessary supports, fittings, valves & ref. joints where ever required will be included. The exposed refrigerent insulated piping shall be covered with UV Resistance canvass coating. | |||||
Tender Value
₹19.1 L
EMD Value
₹38,255
Closing Date
8 Dec 2025, 2:10 pmClosed
Superintending Engineer (E and M)
Office of RAC Unit,1st Floor, Old Building, IIT Kharagpur, Kharagpur WB 721302
Supply, Installation, Testing and Commissioning of Air conditioning of the Classrooms (F-244) at Electrical Engineering Department, IIT Kharagpur.
2025_IITKG_885837_1
IITKGP/IW/RAC/F-244/2025
Open Tender
Electrical Works
Item Rate
100 days
Kharagpur
Please refer Tender documents.
8 documents required · 8 mandatory
₹0
₹38,255
Meeting Room of SE (E and M)
24 Dec 2025
17 Nov 2025
9 Dec 2025
17 Nov 2025
8 Dec 2025
17 Nov 2025
24 Nov 2025
Amount
Supply, Installation, Testing & Commissioning of Air Cooled type outdoor units of VRF system having hermetically sealed inverter scroll/twin rotary compressor, condenser coil fabricated from Seamless Copper tube & Plate type Al. Fins of Multi Row, Axial Flow, top discharge throw condenser fan, Condenser fan - motor unit, all system controls-safety. The system should have flexibility to handle total 280 Rmt of ref. piping. ODU shall be placed on structure with heavy duty anti vibrational pad to protect the system from any kind of unwanted vibration. The system shall have minmum COP of 3.7 at ARI condition as per CPWD guidelines. Each Outdoor units with High Pressure switch, Fan driver overload protector, Over current relay, Inverter Overload Protector & Fusible Plug. The unit shall be suitable for 415 ± 10 % volts, 50 Hz, 3 phase AC supply, and IP protection will be suitable for outdoor installation. The VRF System shall have green ref. gas only- R410A/ R407
Indoor Units Supply, Installation, Testing & Commissioning of Indoor units address setting and capacity as mentioned below. Multi speed motor, coil section with DX coil, outer cabinet, drain pan mechanism insulation, pipe connections, clamp metal, washer fixing plate, sealing pads, screws, clamps, washer for hanging bracket & insulation for fitting, fresh air intake connector for cassettes etc. of various capacities as per specifications. Power cabling (3mtr from unit) with conduit from power socket & plug top to indoor is inclusive of price.
Hi-Wall Type Indoor Unit - Capacity - 2.0TR
Mid High static Ductable Type Indoor Unit With Remote Control - Capacity – 4TR
VRF Y JOINTS FOR BRANCH DISTRIBUTION REFRIGERENT PIPE JOINTS WITH PRECAST INSULATION
REMOTE CONTROLLER
Supply, installation, testing & commissioning of Cordlesss remotes for VRF indoor units
SITC of VRF Refrigerant Piping: Supply, installation, testing & commissioning of Seamless heavy gauge Copper piping of following size duly insulated with 13 mm/ 19mm thk. Nitrile Rubber Insulation covered with aluminium foil ( As per Specified with K Value of 0.027-0.029 K Cal/Hr.M Deg C at 0-16 Deg C) . Refrigeration piping will have to be taken in the piping rack / Support individually connecting to all indoor units for the respective floors. Even necessary supports, fittings, valves & ref. joints where ever required will be included. The exposed refrigerent insulated piping shall be covered with UV Resistance canvass coating.
31.8 mm O.D.(with 19 mm insulation )
28.6 mm O.D.(with 19 mm insulation )
25.4 mm O.D..(with 19 mm insulation )
22.2 mm O.D..(with 19 mm insulation )
19.05 mm O.D..(with 19 mm insulation )
15.88 mm O.D..(with 19 mm insulation )
12.7 mm O.D..(with 19 mm insulation )
19.1 mm O.D..(with 13 mm insulation )
15.9 mm O.D..(with 13 mm insulation )
12.7 mm O.D.(with 13mm insulation )
9.52 mm O.D.(with 13mm insulation )
6.35 mm O.D.(with 13mm insulation )
Supply, Installation and Testing of rigid UPVC Drain Piping complete with fittings, supports as per specifications and duly insulated with 6 mm thick closed cell nitrile rubber insulation.
32 mm dia
25 mm dia
SITC of GI perforated Cable Tray for the refrigerant pipe hanging & Covering
Supply & fixing of control cum transmission wiring of Copper conductor Shielded cable along with PVC conduit / casing for looping between indoor & outdoor VRF system.
2 C X 1.5 Sq. mm (Communication cable)
3 C X 1.5 Sq. mm - PVC insulated & PVC sheathed cable for IDU power connection
Supply, installation, testing & commissioning of require size copper conductor steel armoured power cable with termination to individual Outdoor units.(From Power Panel to VRF ODU)
Civil foundation of VRF ODU
Making wall opening for passage in the wall/glass for ref & drain pipes and cables and making good of the same for all the indoor/ outdoor units.
Decorative Pelmets of required size for fixing of IDUs on wall with 16 mm thick anti termite laminated board.
Supply and erection of GSS ducting with flexible connection with insulated flexible duct for grilles as given in specification.
Supply, installation & testing of Thermal insulation of supply/return air duct (inside the room) with 19mm thick Al foil faced nitrile rubber (Class: O) and joint sealed with Al tape as per specification.
Supply, installation & testing of Acoustic insulation for Supply air duct using Armasound with 10 mm thick class 1 rating Open cell nitrile rubber with density of 140 - 180 kg / m³.
Aluminium Powder coated Grille for supply/return air with al collar damper.
Fresh air arrangement with GI vcd, bird screen & cowl.
Duct Dampers at IDU Opening
Comprehensive AMC of the VRF system for four years after DLP.
Comprehensive AMC 1st Year after DLP
Comprehensive AMC 2nd Year after DLP
Comprehensive AMC 3rd Year after DLP
Comprehensive AMC 4th Year after DLP
SATYA AIRCON AND ENG SERVICES PRIVATE LIMITED (BID ID -3328845)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.31 MB
BOQ_931100.xls
BOQ • 0.41 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .