Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.3 LAccepted-AOC G 58 KIRAN GARDEN UTTAM NAGAR NEW DELHI 110059 | NEW DELHI | WEST DELHI | DELHI | 110059 | ₹12.3 L Quoted ₹12.7 L | L1 | Accepted-AOC Being L1 Bidder |
| 2 | L2₹12.8 L+₹6,315 (0.50%)Rejected-AOC | ₹12.8 L+₹6,315 (0.50%) | L2 | Rejected-AOC Not L1 Bidder |
| 3 | L3₹13.4 L+₹67,600 (5.31%)Rejected-AOC BUILDING NO FLAT NO 19 6TH CROSS ROAD SANJEEVINI NAGAR MUDALAPALYA BANGALORE 560072 | BANGALORE | BANGALORE | KARNATAKA | 560072 | ₹13.4 L+₹67,600 (5.31%) | L3 | Rejected-AOC Not L1 Bidder |
| 4 | L4₹13.6 L+₹86,566 (6.79%)Rejected-AOC SHOP NO 13 45 FEET ROAD BHARAT COLONY FARIDABAD HARYANA 121014 | FARIDABAD | HARYANA | 121014 | ₹13.6 L+₹86,566 (6.79%) | L4 | Rejected-AOC Not L1 Bidder |
| 5 | L5₹14.0 L+₹1.2 L (9.53%)Rejected-AOC 0001 000 KACHARI ROAD RAMAIPATTI MIRZAPUR UTTAR PRADESH 231001 | MIRZAPUR | UTTAR PRADESH | 231001 | ₹14.0 L+₹1.2 L (9.53%) | L5 | Rejected-AOC Not L1 Bidder |
Tender Value
₹19.8 L
EMD Value
₹39,540
Closing Date
22 May 2023, 6:00 pmClosed
REPAIR REPLACEMENT OF LT PANEL CONNECTION CABLES A
REPAIR REPLACEMENT OF LT PANEL CONNECTION CABLES AND ALLIED WORKS IN THE AREA OF AGE U WS II UNDER GE U WATER SUPPLY DELHI CANTT 10
REPAIR REPLACEMENT OF LT PANEL CONNECTION CABLES AND ALLIED WORKS IN THE AREA OF AGE U WS II UNDER GE U WATER SUPPLY DELHI CANTT 10
2023_MES_579090_2
8222/GE/WS/Token-20/2022-23
Open Tender
Civil Works
Item Rate
180 days
REPAIR REPLACEMENT OF LT PANEL CONNECTION CABLES A
REPAIR REPLACEMENT OF LT PANEL CONNECTION CABLES AND ALLIED WORKS IN THE AREA OF AGE U WS II UNDER GE U WATER SUPPLY DELHI CANTT 10
5 documents required · 5 mandatory
₹500
GE U WATER SUPPLY DELHI CANTT 10
₹39,540
Yes
18 Sept 2023
2 May 2023
24 May 2023
2 May 2023
22 May 2023
9 May 2023
Amount
Taking out existing LT UG cable laid in trenches or fixed to poles etc safely for relaying at new/old position after testing of existing cable for serviceability of following sizes :- (Note : Excavation and earth work shall be measured and paid seperately under relevant items)
10 Sqmm 4 Core
16 Sqmm 4 Core
25 Sqmm 3.5 Core
35 Sqmm 3.5 Core
50 Sqmm 3.5 Core
70 Sqmm 3.5 Core
95 Sqmm 3.5 Core
120 sqmm 3.5 Core
Relaying & testing commissioning of existing LT UG cable laid in trenches or fixed to poles same after connected repair works of cable & providing new lugs & thimbs of following sizes :- (Note : Excavation and earth work shall be measured and paid seperately under relevant items)
10 Sqmm 4 Core
16 Sqmm 4 Core
25 Sqmm 3.5 Core
35 Sqmm 3.5 Core
50 Sqmm 3.5 Core
70 Sqmm 3.5 Core
95 Sqmm 3.5 Core
120 sqmm 3.5 Core
S&F laying, testing & commissioning of new XLPE insulated, screened, PVC bedded,galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts, grade of following dia of cable laid in trenches or fixed to poles complete all as specified and directed. (Note : Excavation and earth work shall be measured and paid seperately under relevant items)
10 Sqmm 4 Core
16 Sqmm 4 Core
25 Sqmm 3.5 Core
35 Sqmm 3.5 Core
50 Sqmm 3.5 Core
70 Sqmm 3.5 Core
95 Sqmm 3.5 Core
120 sqmm 3.5 Core
Labour only for laying existing serviceable burnt bricks sub class 'B' old size laid in trenches with equal to length of bricks across the cable for cable protection complete all as specified and directed (Note:- Old serviceable bricks shall be stacked at site and unserviceable bricks/brick bat shall be credited to contractor at credit rate.)
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 metre depth and getting out in hard/dense soil for taking out/laying cables complete all as specified and directed
Returning, filling in including spreading levelling watering and well ramming in layers not exceeding 25 cm in hard / dense soil complete all as specified and directed
Removing excavated soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed
Supply and spread in layers clean dry Jamuna river sand free from vegetation & dust to required width at bottom and top for cable cushioning complete all as specified and directed. (Note :- Punned depth of sand of compacting of sand by hand roller shall be measured & paid.)
M&L for laying of Burnt bricks sub class 'B' old size laid in trenches with equal to length of bricks across the cable for cable protection complete all as specified and directed.
Supply and fixing in replacement of decorative gate light MASHROOM (PRISMATIC) including 20W LED lamp made up of high grade breakable polycarbonate material for retrofit complete all as specified and directed.
Repair/maintenance of decorative gate light including replacement of LED lamp,damaged light cover,cable, & MCB or make it serviceable functional as per site and fixed where directed complete all as specified. (Note:- Old unservieable parts shall be credited to contractor and quoted rate shall be deemed includings all repair and replacement cost of light fitting making fully functional and fixed at site after repair/replacement of parts.)
Supply and fixing in replacement of 20W surface/wall mounted 4 feet LED batten light with all fitting, extruded aluminium housing provided complete all as specified and directed.
M&L for point wiring 1.5 Sqmm PVC insulated and unsheathed cable with PVC insulated FRLS multistranded copper conductor 1100 Volts grade, alongwith 1.5 sqmm PVC insulated FRLS multistanded copper, earth dully connected including steel concealed sunken box, nut bolts etc earth wire in existing surface / recessed surface in PVC conduits 25mm dia 'medium grade' including taking down worn out existing point wiring and painting with two coat of cement base point over new plastered surface to match the existing surface etc complete all as specified and directed.
All as per item No 13 above but in power point with 2.5 sqmm PVC insulated FRLS type copper wire as in main & neutral and 2.5 sqmm PVC insulated FRLS type copper earth wire.
Taking down old UNSV of any description type changeover switch and S&F new changeover switches in sheet steel encloser 415V, 50 Hz 200Amps, 4 Pole on load type existing pole/wall complete all as specified and directed.
Taking down old UNSV any type changeover switch and S&F new changeover switches in sheet steel encloser 415V, 50 Hz 250 Amps 4 Pole, on load type on existing pole/wall complete all as specified and directed.
Taking down the unserviceable power contactor of any size and replacement with S&F of new power contactor ML 1.5 type in existing starter panel complete all as specified and directed
Taking down the unserviceable power contactor of any size and replacement with S&F of new power contactor ML 2 type in existing starter panel complete all as specified and directed
Taking down the unserviceable power contactor of any size and replacement with S&F of new power contactor ML 3 type in existing starter panel complete all as specified and directed
Taking down the unserviceable power contactor of any size and replacement with S&F of new power contactor ML 4 type in existing starter panel complete all as specified and directed
Taking down the unserviceable power contactor or any size and supply and fixing new power contactor MNX 18 type in existing starter panel complete all as specified and directed
Taking down the unserviceable power contactor or any size and supply and fixing new power contactor MNX 32 type in existing starter panel complete all as specified and directed
Taking down the unserviceable power contactor or any size and supply and fixing new power contactor MNX 40 type in existing starter panel complete all as specified and directed
Taking down the unserviceable power contactoror any size and supply and fixing new power contactor MNX 70 type in existing starter panel complete all as specified and directed
Taking down the unserviceable power contactor or any size and supply and fixing new power contactor MNX 95 type in existing starter panel complete all as specified and directed
Taking down the unserviceable power contactor or any size and supply and fixing new power contactor MNX 110 type in existing starter panel complete all as specified and directed
Taking down the unserviceable FASD ML 1.5 type (with MU relay) of any size and replacement with S&F of new FASD ML 1.5 type(with MU relay) including stainless steel box existing starter panel complete all as specified and directed
Taking down the unserviceable FASD ML 2 type(with MU relay) of any size and replacement with S&F of new FASD ML 2 type (with MU relay) including stainless steel box existing starter panel complete all as per specified and directed.
Taking down the unserviceable FASD ML3 type (with MU relay) of any size and replacement withS&F of new FASD ML3 type(with MU relay) including stainless steel box existing starter panel complete all as specified and directed
Taking down the unserviceable FASD ML 4 type(with MU relay) any size and replacement with S&F of new FASD ML4 type(with MU relay) including stainless steel box existing starter panel complete all as specified and directed
Taking down un-serviceable street light fitting 45W/60W any make and replacement with S&F of new driver/LED lamp existing suitable make and model make it funcional complete all as specified and directed. (Note:- Minor part if required for replacement (worth of Rs. 200/- overall in each fiting) to replacement for making fully functional of street light fittings the same will be provided by contractor at his own cost. Quoted rate shall be deemed included such aspect.)
S&F in replacement of 100W LED street light made up of die cast aluminium housing with hight efficient LED as lightning source with toughened glass having IP66 protection and impact resistance of Ik 07 with inluding all fitting such as suitable cable/GI pipe bracket/MCB for fixing on wall complete all as specified and directed.
Supply and laying earth continuity conductor or main earthing lead 32x6mm galvanised iron strip fixed to wall on batten or recess or chases or burried in ground or drawn in conduit /pipe or fixed to poles or any other indicated situation for loop earthing etc as required including taking down of existing earth strip complete all as specified and directed.
M&L for cable joint kit of size 16 sqmm 4 core for heat shrinkable straight through joint complete all as specified and directed
M&L for cable joint kit of size 25 sqmm 4 core for heat shrinkable straight through joint complete all as specified and directed
M&L for cable joint kit of size 35 sqmm 3.5 core for heat shrinkable straight through joint complete all as specified and directed
M&L for cable joint kit of size 50 sqmm 3.5 core for heat shrinkable straight through joint complete all as specified and directed
M&L for cable joint kit of size 70 sqmm 3.5 core for heat shrinkable straight through joint complete all as specified and directed
M&L for cable joint kit of size 95 sqmm 3.5 core for heat shrinkable straight through joint complete all as specified and directed
M&L for cable joint kit of size 120 sqmm 3.5 core for heat shrinkable straight through joint complete all as specified and directed
M&L for pin point the fault by arranging fault locating machine in any size of LT UG cable from any location/position/situtation, taking down/out the faulty portion of cable, of any length from trenches, jointing with cable jointing kit & testing for satisfactorily serviceable with & including necessary excavation and earth work, sand cushioning and making necessary connections to make it functional complete all as specified and directed. Note :- (i) Cable jointing kit shall be measured and paid seperetely. (ii) Old retrieved bricks/cable cover shall be reused (iii) The rates quoted includes excavation & earth work with sand cushioning.
Taking down the Direct on line starter for 5 Hp motor relay range 7-10Amp and replacement with S&F of new DOL starter 5 Hp relay range 7-10Amp in existing starter panel complete all as specified and directed
Taking down the Direct on line starter for 7.5 Hp motor relay range 10-13Amp and replacement with S&F of new DOL starter 7.5 Hp relay range 10-13Amp in existing starter panel complete all as specified and directed
Taking down the Direct on line starter for 10 Hp motor relay range 13-18 Amp replacement with S&F of new DOL starter 10 Hp relay range 13-18 Amp in existing starter panel complete all as specified and directed
S&F of Direct mounting on ML 1.5 contractor Thermal over load relay, relay range 6-10 Amps suitable for fixing in existing panel in replacement complete all as specified and directed.
S&F of Direct mounting on ML 1.5 contractor Thermal over load relay, relay range 10-16 Amps suitable for fixing in existing panel in replacement complete all as specified and directed.
S&F of Direct mounting on ML 2/3 contractor Thermal over load relay, relay range 13-21 Amps suitable for fixing in existing panel in replacement complete all as specified and directed.
S&F of Direct mounting on ML 2/3 contractor Thermal over load relay, relay range 20-32 Amps suitable for fixing in existing panel in replacement complete all as specified and directed.
S&F of Direct mounting on ML 2/3 contractor Thermal over load relay, relay range 28-42 Amps suitable for fixing in existing panel in replacement complete all as specified and directed.
Supply & fixing LED bulb 9 Watt B 22 lumen efficiency 90 Im/w,white cool day light complete all as specified and directed
M&L repair to existing earthing pit by dismentling unserviceable brick work after necessary excavation & earth work and construction of pit with new brick work using well brunt sub class B brick old size and 15mm thick rendering in CM (1:4) as required,replacing alternate layer of charcoal % salt as per electrical plate No-03, providing & connected earthing lead wire 4 mm dia of length as required by means of bolt,nuts and check nuts to make earthing funcional after testing complete all as specified and directed. (Note:- Each earthing shall be tested independentely and record the test report dully signed & passed by EIC.)
S&F of 1.5 Sqmm PVC insulated copper conductor, Two core cable in surface/ recessed as required complete all as specified and directed
S&F of 25 Sqmm PVC insulated copper conductor, single core cable in surface/ recessed as required complete all as specified and directed
S&F of 35 Sqmm PVC insulated copper conductor, single core cable in surface/ recessed as required complete all as specified and directed
M & L for mild steel work for repair/maintenace of LT panel including repair of panel cover/mild steel angle iron frame / hinges / PCC work for fixing panel properly and welding works confirming Fe-290,Gde E-165 including taking down of existing frame complete all as specified and directed. (Note:- Cost of PCC work as per site requirement of each panel shall be deemed included in quoted rate.)
M&L for painting on steel and iron surfaces with two coat of synthetic enamel paint as per existing colour scheme or pattern after preparation of old painted surface of any description over 10cm in width or girth the frame should be with anticorrosive coating and finaly epoxy ployster powder coating complete all as specified and directed
Taking down the unserviceable electronic timer ST 100 and S&F new elecrtonic timer type ST 100 for fixing in panel complete all as specified and directed
Taking down the unserviceable single phase preventor VSP 2 from existing panel and replacement with new single phase preventor VSP 2 complete all as specified and directed
Taking down existing UNSV switch piano of 5 Amp and Supply & fixing new Switch piano, flush type, single pole one way for 5 Amps complete all as specified and directed.
Taking down existing UNSV switch piano 15 Amp Supply and fixing new Switch piano,flush type,single pole one way for 15 Amps complete all as specified and directed.
Taking down existing UNSV switch socket combination 5 amp and Supply & fixing new switch socket combination of rating 5 Amp flush type 3 Pin complete all as specified and directed.
Taking down existing UNSV socket combination 16 amp and Supply & fixing new switch socket combination of rating 16 Amp flush type 5 Pin complete all as specified and directed.
Taking down existing UNSV 5 amp socket and Supply & fixing socket outlet 2 in 1,3 pin of rating 5 Amp.
Taking down existing UNSV 15 Amp socket and Supply & fixing new socket outlet 2 in 1,3 pin of rating 15 Amp complete all as specified and directed..
Supply and fixing in replacement of MCCB 3 pole 415 volt adjustable type 63Amp with breaking capacity 25KA complete all as specified and directed
Supply and fixing in replacement of MCCB 3 pole 415 volt adjustable type 100Amp with breaking capacity 27KA complete all as specified and directed
Supply and fixing in replacement of MCCB 4 pole 415 volt adjustable type 160 Amp with breaking capacity 36KA complete all as specified and directed
Supply and fixing in replacement of MCCB 4 pole 415 volt adjustable type 200 Amp with breaking capacity 36KA complete all as specified and directed
Supply and fixing in replacement of MCCB 4 pole 415 volt adjustable type 250 Amp with breaking capacity 36KA complete all as specified and directed
Supply and fixing in replacement of MCCB 4 pole 415 volt adjustable type 320 Amp with breaking capacity 36 KA complete all as specified and directed
Supply and fixing in replacement of MCB single pole adjustable type 6 Amp of capacity 10KA complete all as specified and directed
Supply and fixing in replacement of MCB single pole adjustable type 10 Amp of capacity 10KA complete all as specified and directed
Supply and fixing in replacement of MCB single pole adjustable type 16 Amp of capacity 10 KA complete all as specified and directed
Supply and fixing in replacement of MCB Double pole adjustable type 32 Amp of capacity 10 KA complete all as specified and directed
Supply and fixing in replacement of MCB Double pole adjustable type 40 Amp of capacity 15 KA complete all as specified and directed
Supply and fixing in replacement of MCB Double pole adjustable type 50 Amp of capacity 15 KA complete all as specified and directed
Supply and fixing in replacement of MCB Three pole adjustable type 63 Amp of capacity 15 KA complete all as specified and directed
Note:- Sch of credit amount of Rs. 45803/- shall be deducted from total quoted BOQ Amount when work acceptance letter issued.
Satish Kumar Gupta
Rahul Enterprises
Haryana EngineerService
KUSHAL ENTERPRISES
KISHORE ENTERPRISES
Ridhi engineers and builders
AMIT ENTERPRISES
Surjit and Sons
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .