Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.4 LAccepted-Finance | ₹37.4 L | L1 | Accepted-Finance Being L1 |
| 2 | L2₹38.5 L+₹1.1 L (2.96%)Rejected-Finance | ₹38.5 L+₹1.1 L (2.96%) | L2 | Rejected-Finance Other than L1 |
| 3 | L3₹38.7 L+₹1.4 L (3.65%)Rejected-Finance | ₹38.7 L+₹1.4 L (3.65%) | L3 | Rejected-Finance Other than L1 |
| 4 | L4₹39.9 L+₹2.5 L (6.81%)Rejected-Finance | ₹39.9 L+₹2.5 L (6.81%) | L4 | Rejected-Finance Other than L1 |
| 5 | L5₹41.7 L+₹4.3 L (11.5%)Rejected-Finance | ₹41.7 L+₹4.3 L (11.5%) | L5 | Rejected-Finance Other than L1 |
| Sl No | Description | Qty | Unit | DARVESH ENGINEERING WORKS L1 | Ashok and Co L6 | BMMJ ENGINEERS AND TRADERS L2 | M/S S K Electricals Regd L5 | CELMAC REGD L8 | M/S RAJ ENGINEERS L4 | HARSH ELECTRICAL STORE L7 | ASHOKKUMAR SURI L3 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches in any type of soil, not exceeding 1.5m deep and 1.5m wide for foundation etc or manholes, piers , shafts etc not exceeding 10 Sqm on plan & not exceeding 1.5m in depth and getting out complete all as specified and directed. | 873.2 | Cum | 90 ₹78,588 Lowest | 150 ₹1,30,980 | 100 ₹87,320 | 120 ₹1,04,784 | 200 ₹1,74,640 | 120 ₹1,04,784 | 100 ₹87,320 | 108 ₹94,305.6 |
| 2.00 | Returning , filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm complete all as specified and directed | 616.22 | Cum | 15 ₹9,243.3 | 20 ₹12,324.4 | 20 ₹12,324.4 | 20 ₹12,324.4 | 70 ₹43,135.4 | 5 ₹3,081.1 Lowest | 50 ₹30,811 | 27 ₹16,637.94 |
| 3.00 | Removing excavated material to a distance n.exc 50m & depositing where directed at a level n. exc 1.5 m above the starting point complete all as specified and directed. | 241.99 | Cum | 15 ₹3,629.85 | 20 ₹4,839.8 | 20 ₹4,839.8 | 30 ₹7,259.7 | 70 ₹16,939.3 | 6 ₹1,451.94 Lowest | 50 ₹12,099.5 | 36 ₹8,711.64 |
| 4.00 | M&L for sand cushioning with a layer of dry river sand, 80mm thick before laying of cable and 150mm thick (punned down to 100mm thick) after laying of cables, in trenches/ducts, complete all as specified and directed.
Note : Punned down thickness (overall 18cm), shall be considered for measurement and payment. | 266 | Cum | 140 ₹37,240 Lowest | 400 ₹1,06,400 | 400 ₹1,06,400 | 300 ₹79,800 | 450 ₹1,19,700 | 400 ₹1,06,400 | 200 ₹53,200 | 450 ₹1,19,700 |
| 5.00 | M&L for factory made unreinforced precast concrete cable cover LV type-1, flat, of size 250x150x40mm, laid flat and dry in trenches over the cable for protection, length perpendicular to the direction of cable adjacent to each other, complete all as specified and directed. | 19,750 | Each | 5 ₹98,750 Lowest | 10 ₹1,97,500 | 8 ₹1,58,000 | 9 ₹1,77,750 | 25 ₹4,93,750 | 12 ₹2,37,000 | 5 ₹98,750 Lowest | 9 ₹1,77,750 |
| 6.00 | Supply & erecting in truly vertical position steel tubular swaged poles, type 410 SP-31(9.00 meters long) complete with cast iron base plate, finial taper plug, bolts, nuts & screws, including marking pole numbers in a 15 cm dia yellow circle with number writting with black synenthic paint/ Stricker including painting strips in alternate from bottom to top with three strips of white synthetic enamel paint & two strips of Yellow/ black paint throughout the circumference of pole including one coat of lime wash on PCC copping of pole complete all as specified and directed.. | 56 | Each | 15,000 ₹8,40,000 Lowest | 18,000 ₹10,08,000 | 17,000 ₹9,52,000 | 18,000 ₹10,08,000 | 15,000 ₹8,40,000 Lowest | 18,900 ₹10,58,400 | 20,000 ₹11,20,000 | 16,200 ₹9,07,200 |
| 7.00 | M&L for plain cement concrete 1:4:8, type D2 (using 40 mm graded crushed stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed . | 18.75 | Cum | 2,500 ₹46,875 | 3,000 ₹56,250 | 3,000 ₹56,250 | 1,800 ₹33,750 Lowest | 2,800 ₹52,500 | 1,800 ₹33,750 Lowest | 3,000 ₹56,250 | 3,600 ₹67,500 |
| 8.00 | M&L for plain cement concrete1:2:4, type B-1 (using 20 mm graded crushed stone aggregates) as in coping of poles,stay assembly, plate form of transformer etc including weathering, slightly rounded or chamfered angle and throating, necessary form work and fair finishing all exposed faces of concrete without using extra cement complete all as specified and directed | 9.5 | Cum | 3,000 ₹28,500 | 3,500 ₹33,250 | 3,500 ₹33,250 | 3,000 ₹28,500 | 3,800 ₹36,100 | 2,300 ₹21,850 Lowest | 3,000 ₹28,500 | 3,600 ₹34,200 |
| 9.00 | Supply, laying, jointing, testing and commissioning of Low Tension (LT) XLPE insulated, armoured, heavy duty, electric power cable, cross sectional area 16 Sqmm, 4 core, aluminum conductor, 1100 volts grade under ground cable including both side connection with lugs/thimbles of suitable size etc, laid in trenches, along poles or passing through pipes or laid under floor or through walls etc, complete all as specified and directed. | 3,188 | RM | 175 ₹5,57,900 | 150 ₹4,78,200 | 140 ₹4,46,320 Lowest | 220 ₹7,01,360 | 160 ₹5,10,080 | 169 ₹5,38,772 | 250 ₹7,97,000 | 180 ₹5,73,840 |
| 10.00 | Supply, laying, jointing, testing and commissioning of Low Tension (LT) XLPE insulated, armoured, heavy duty, electric power cable, cross sectional area 70 Sqmm, 3.5 core, aluminum conductor, 1100 volts grade under ground cable including both side connection with lugs/thimbles of suitable size etc, laid in trenches, along poles or passing through pipes or laid under floor or through walls etc, complete all as specified and directed. | 50 | RM | 500 ₹25,000 | 420 ₹21,000 | 400 ₹20,000 | 520 ₹26,000 | 540 ₹27,000 | 490 ₹24,500 | 300 ₹15,000 Lowest | 450 ₹22,500 |
Tender Value
₹48.4 L
EMD Value
₹96,780
Closing Date
21 Aug 2026, 6:00 pmClosed
GE SATWARI
GE SATWARI
Provn of certain sanctioned works under AGE E/M of GE Satwari
2026_MES_780560_1
GEJM-24/2026-27
Open Tender
Electrical and Maintenance Works
Works
180 days
GE SATWARI
Class D Cat b (i)
9 documents required · 9 mandatory
₹500
GE SATWARI
₹96,780
Yes
5 Sept 2026
24 Jul 2026
24 Aug 2026
24 Jul 2026
21 Aug 2026
7 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Excavation in trenches in any type of soil, not exceeding 1.5m deep and 1.5m wide for foundation etc or manholes, piers , shafts etc not exceeding 10 Sqm on plan & not exceeding 1.5m in depth and getting out complete all as specified and directed. | 873.2 | Cum | - | - |
| 2 | Returning , filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm complete all as specified and directed | 616.22 | Cum | - | - |
| 3 | Removing excavated material to a distance n.exc 50m & depositing where directed at a level n. exc 1.5 m above the starting point complete all as specified and directed. | 241.99 | Cum | - | - |
| 4 | M&L for sand cushioning with a layer of dry river sand, 80mm thick before laying of cable and 150mm thick (punned down to 100mm thick) after laying of cables, in trenches/ducts, complete all as specified and directed.
Note : Punned down thickness (overall 18cm), shall be considered for measurement and payment. | 266 | Cum | - | - |
| 5 | M&L for factory made unreinforced precast concrete cable cover LV type-1, flat, of size 250x150x40mm, laid flat and dry in trenches over the cable for protection, length perpendicular to the direction of cable adjacent to each other, complete all as specified and directed. | 19,750 | Each | - | - |
| 6 | Supply & erecting in truly vertical position steel tubular swaged poles, type 410 SP-31(9.00 meters long) complete with cast iron base plate, finial taper plug, bolts, nuts & screws, including marking pole numbers in a 15 cm dia yellow circle with number writting with black synenthic paint/ Stricker including painting strips in alternate from bottom to top with three strips of white synthetic enamel paint & two strips of Yellow/ black paint throughout the circumference of pole including one coat of lime wash on PCC copping of pole complete all as specified and directed.. | 56 | Each | - | - |
| 7 | M&L for plain cement concrete 1:4:8, type D2 (using 40 mm graded crushed stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed . | 18.75 | Cum | - | - |
| 8 | M&L for plain cement concrete1:2:4, type B-1 (using 20 mm graded crushed stone aggregates) as in coping of poles,stay assembly, plate form of transformer etc including weathering, slightly rounded or chamfered angle and throating, necessary form work and fair finishing all exposed faces of concrete without using extra cement complete all as specified and directed | 9.5 | Cum | - | - |
| 9 | Supply, laying, jointing, testing and commissioning of Low Tension (LT) XLPE insulated, armoured, heavy duty, electric power cable, cross sectional area 16 Sqmm, 4 core, aluminum conductor, 1100 volts grade under ground cable including both side connection with lugs/thimbles of suitable size etc, laid in trenches, along poles or passing through pipes or laid under floor or through walls etc, complete all as specified and directed. | 3,188 | RM | - | - |
| 10 | Supply, laying, jointing, testing and commissioning of Low Tension (LT) XLPE insulated, armoured, heavy duty, electric power cable, cross sectional area 70 Sqmm, 3.5 core, aluminum conductor, 1100 volts grade under ground cable including both side connection with lugs/thimbles of suitable size etc, laid in trenches, along poles or passing through pipes or laid under floor or through walls etc, complete all as specified and directed. | 50 | RM | - | - |
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.29 MB
Tender24.pdf
Tender Documents • 1.02 MB
BOQ_874363.xls
BOQ • 0.39 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .